Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
J Xray Sci Technol ; 32(5): 1315-1329, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39031429

RESUMO

X-ray communication is a kind of space communication technology which uses X-ray as information carrier. In order to improve the information transmission capacity, communication rate and anti-interference ability of X-ray communication, we proposes to design a novel multi-target X-ray source. The source is composed of a fast switching module of light channels based on FPGA technology and four photoelectric X-ray tubes with different target materials: Cr, Fe, Ni, and Cu. Using Geant4 software, we determined the optimal target thickness for each material, which enabled us to fully leverage the characteristic X-rays for multi-channel signal modulation transmission. Moreover, using CST software for particle trajectory simulation and optimization of the electron beam revealed that at a tube voltage of 20 kV, the focus area measures approximately 1.2 mm×1.2 mm. The simulations show that four kinds of spectra with high distinctiveness can be generated from the Cr, Fe, Ni, and Cu targets. Within a single modulation period, these spectra can be combined in various ways to create 16 different X-ray spectra signals, thereby increasing the number of communication elements and enhancing the information transmission rate.


Assuntos
Desenho de Equipamento , Raios X , Software , Simulação por Computador
2.
J Radiol Prot ; 43(4)2023 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-37944177

RESUMO

To determine the eye lens dose (3 mm dose equivalent [Hp(3)]) received by spine surgeons during myelography and evaluate the effectiveness of radiation-protective glasses and x-ray tube system positioning in reducing radiation exposure. This study included spine surgeons who performed myelography using over- or under-table x-ray tube systems. Hp(3) was measured for each examination using a radio-photoluminescence glass dosimeter (GD-352M) mounted on radiation-protective glass. This study identified significantly high Hp(3) levels, especially in the right eye lens in spinal surgeons. The median Hp(3) values in the right eye were 524 (391-719) and 58 (42-83)µSv/examination for over- and under-table x-ray tube systems, respectively. Further, Hp(3)AK, which was obtained by dividing the cumulative air kerma from Hp(3), was 8.09 (6.69-10.21) and 5.11 (4.06-6.31)µSv mGy-1for the over- and under-table x-ray tube systems, respectively. Implementing radiation-protective glasses resulted in dose reduction rates of 54% (50%-57%) and 54% (51%-60%) for the over- and under-table x-ray tube systems, respectively. The use of radiation protection glasses significantly reduced the radiation dose in the eye lens during myelography, with the most effective measures being the combination of using radiation protection glasses and an under-table x-ray tube system.


Assuntos
Cristalino , Exposição Ocupacional , Cirurgiões , Humanos , Doses de Radiação , Mielografia , Exposição Ocupacional/análise
3.
J Appl Clin Med Phys ; 22(8): 204-218, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34196461

RESUMO

PURPOSE: To develop a method to perform quality control (QC) of X-ray tubes and automatic exposure control (AEC) as a part of the QC of the radiographic and fluoroscopic X-ray system. Our aim is to verify the output from the X-ray tube by comparing the measured radiation output, or air kerma, to the theoretical output given the applied exposure settings and geometry, in addition to comparing the measured kV to the nominal kV. The AEC system for fluoroscopic and conventional X-ray systems is assessed by determining the absorbed dose to a homogenous phantom with different thicknesses. METHOD: This study presents a model to verify the X-ray tube measurement results and a method to determine the dose to a homogenous phantom (Dphantom ). The following input is needed: a parameterized model of the X-ray spectrum, the X-ray tube measurements using a multifunctional X-ray meter, the exposure parameters recorded via imaging of polymethyl methacrylate (PMMA) slabs of different thickness that simulate the patient using AEC, and a parameterized model for calculating the dose to water from Monte Carlo simulations. The output is the entrance surface dose (ESD) and absorbed dose in the phantom, Dphantom (µGy). In addition, the parameterized X-ray spectrum is used to compare theoretical and measured air kerma as a part of the QC of the X-ray tube. To verify the proposed method, the X-ray spectrum provided in this study, SPECTRUM, was compared to two commercially available spectra, SpekCalc and Institute of Physics and Engineering in Medicine (IPEM) 78. The fraction of energy imparted to the homogenous phantom was compared to the imparted fraction calculated by PCXMC. RESULTS: The spectrum provided in this study was in good agreement with two previously published X-ray spectra. The absolute percentage differences of the spectra varied from 0.05% to 3.9%, with an average of 1.4%, compared to SpekCalc. Similarly, the deviation from IPEM report 78 varied from 0.02% to 2.3%, with an average of 0.74%. The SPECTRUM was parameterized for calculation of the imparted fraction for target angles of 10°, 12°, and 15°, kV (50-150 kV) with the materials Al (2.2-8 mm), Cu (0-1 mm), and any combination of the filters, PMMA and water. The deviation of energy imparted from the results by PCXMC was less than 8% for all measurements across different kV, filtration, and vendors, obtained by using PMMA to record the exposure parameters, while the dose was calculated based on water with same thicknesses as the PMMA. CONCLUSION: This study presents an accurate and suitable method to perform a part of the QC of fluoroscopic and conventional X-ray systems with respect to the X-ray tube and the associated AEC system. The method is suitable for comparing protocols within and between systems via the absorbed dose.


Assuntos
Raios X , Fluoroscopia , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Controle de Qualidade , Doses de Radiação
4.
J Xray Sci Technol ; 29(5): 813-821, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34151881

RESUMO

BACKGROUND: Low-tube voltage scanning improves CT attenuation value of contrast medium (CM). Thus, we hypothesized that 70 kVp in pediatric abdominal CT angiography (CTA) could be used to reduce both radiation and CM dose and improve patient comfort at the same time. OBJECTIVE: To evaluate the feasibility of using 70 kVp in pediatric abdominal CTA to reduce radiation dose and CM dose and improve patient care for children. MATERIALS AND METHODS: Forty-six children needing abdominal CTA were enrolled in the study group using low-dose scanning protocol with 70 kVp and 0.7-1.1 ml/kg contrast dose, and reconstructed with 50%ASIR-V. They were compared with other 46 children in control group with matching body weight and underwent conventional CT scans with 100 kVp, 1.2-1.8 ml/kg contrast dose and reconstructed using 50%ASIR. Image quality of large vessels was evaluated using a 5-point scale. CT value and standard deviation of descending aorta (Ao) was measured, and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Radiation dose, contrast dose, the maximum injection pressure between the two groups were also compared. RESULTS: Score for displaying large vessels by 70 kVp images was 3.91±0.28, lower than that (4.17±0.38) of the control group (p < 0.05), but fully met the diagnostic requirements. CT value of Ao was 390.87±86.79HU in study group, which is higher than 343.93±49.94HU in control group, while there was no difference in SNR and CNR between two groups; the radiation dose, contrast dosage and injection pressure of the study group were 1.23±0.39mGy, 12.67±7.27 ml and 43.83±17.16psi, respectively, which are significantly lower than the 1.95±0.37mGy, 22.67±7.39 ml, and 77.59±19.68psi of control group. CONCLUSION: Use of 70 kVp in pediatric abdominal CTA provides diagnostic quality images while significantly reduce radiation and contrast dose, as well as injection pressure to improve patient comfort for children.


Assuntos
Angiografia por Tomografia Computadorizada , Conforto do Paciente , Peso Corporal , Criança , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído
5.
J Xray Sci Technol ; 29(4): 687-695, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34092694

RESUMO

OBJECTIVE: To investigate feasibility of applying deep learning image reconstruction (DLIR) algorithm in a low-kilovolt enhanced scan of the upper abdomen. METHODS: A total of 64 patients (BMI<28) are selected for the enhanced upper abdomen scan and divided evenly into two groups. The tube voltages in Group A are 100kV in arterial phase and 80kV in venous phase, while tube voltages are 120kV during two phases in Group B. Image reconstruction algorithms used in Group A include the filtered back projection (FBP) algorithm, the adaptive statistical iterative reconstruction-Veo (ASIR-V 40% and 80%) algorithm, and the DLIR algorithm (DL-L, DL-M, DL-H). Image reconstruction algorithm used in Group B is ASIR-V40%. The different reconstruction algorithm images are used to measure the common hepatic artery, liver, renal cortex, erector spinae, and subcutaneous adipose in the arterial phase and the average CT value and standard deviation of the portal vein, liver, spleen, erector spinae, and subcutaneous adipose in the portal phase. The signal-to-noise ratio (SNR) is calculated, and the images are also scored subjectively. RESULTS: In Group A, noise in the aorta, liver, portal vein (the portal phase), spleen (the portal phase), renal cortex, retroperitoneal adipose, and muscle is significantly lower in both the DL-H and ASIR-V80% images, and the SNR is significantly higher than those in the remaining groups (P<0.05). The SNR of each tissue and organ in Group B is not significantly different from that in DL-M, DL-L, and ASIR-V40% in Group A (P>0.05). The subjective image quality scores in the DL-H and B groups are higher than those in the other groups, and the FBP group has significantly lower image quality than the remaining groups (P<0.05). CONCLUSION: For upper abdominal low-kilovolt enhanced scan data, the DLIR-H gear yields a more satisfactory image quality than the FBP and ASIR-V.


Assuntos
Aprendizado Profundo , Abdome/diagnóstico por imagem , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
6.
J Appl Clin Med Phys ; 20(6): 160-169, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31095873

RESUMO

Conversion to a filmless technique of physical performance testing is becoming a topic of much interest to researchers. We assessed the use of a computed radiography (CR) system with postprocessing software as an alternative tool for performing the three physical performance tests of an x-ray tube. Collimator and beam alignment, focal spot size, and milliampere second (mAs) linearity, were performed using a CR system. Results were then compared with those obtained from a conventional screen-film (SF) system. The distances of collimator misalignment measured by the SF system were decreased while peak tube voltage (kVp) was increased (mAs was fixed), whereas those measured by CR were independent of exposure level. The degrees of beam collimator misalignment measured by the CR system were not different from those measured by the SF system. The differences in focal spot dimensions measured by SF and CR systems were less than 4% for large and small focal spot size in both width and length. The mAs linearity evaluated by the SF system agreed with those evaluated by the dose measurement at 50 kVp and 4 mAs, as well as 55 kVp and 3.2 mAs, while the mAs linearity test using the CR system agreed with those using the dose measurement method for all exposure levels. In summary, a CR system could be utilized to assess the three physical performance tests of a single x-ray tube, but required more time than an SF system. Medical physicists with image processing skills were needed to perform the analyses.


Assuntos
Dosimetria Fotográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Ampliação Radiográfica/instrumentação , Tomografia Computadorizada por Raios X/métodos , Ecrans Intensificadores para Raios X , Calibragem , Dosimetria Fotográfica/métodos , Humanos
7.
J Xray Sci Technol ; 24(2): 267-78, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27002906

RESUMO

BACKGROUND: In computed tomography (CT), the image contrast is given by the difference in X-ray attenuation in the various tissues of the patient and contrast media are used to enhance image contrast in anatomic regions characterized by similar attenuation coefficients. OBJECTIVE: Aim of the present work is to enlarge the range of applicability of the method previously introduced for organ dosimetry in contrast-enhanced CT, by studying the effects of X-ray beam quality on the parameters of the model. Furthermore, an experimental method for the evaluation of the attenuation properties of iodinated solutions is proposed. METHODS: Monte Carlo simulations of anthropomorphic phantoms were carried out to determine a bi-parametrical (a and b) analytical relationship between iodine concentration and dose increase in organs of interest as a function of the tube kilo-voltage peak potential (kVp) and filtration. Experimental measurements of increments in Hounsfield Units (HU) were conducted in several CT scanners, at all the kVp available, in order to determine the parameter γ which relates the HU increment with the iodine mass fraction. A cylindrical phantom that can be filled with iodine solutions provided with an axial housing for a pencil ionization chamber was designed and assembled in order to measure the attenuation properties of iodine solutions under irradiation of a CT scanner and to obtain a further validation of Monte Carlo simulations. RESULTS: The simulation-derived parameters of the model, a and b, are only slightly dependent upon the tube kilo-voltage peak potential and filtration, while such scanner-dependent features influence mainly the experimentally-derived γ parameter. Relative dose variations registered by the ionization chamber inside the iodine-filled cylindrical phantom decrease when the X-ray mean energy increases, and reaches about 50% for 10 mg/ml of iodine. CONCLUSIONS: The dosimetric method for contrast-enhanced CT can be applied to all CT scanners by adopting average simulative parameters and by carrying out a simple measurement with a series of iodine contrast solutions. The novel experimental methodology introduced can provide a direct measurement of iodine attenuation properties.


Assuntos
Meios de Contraste/química , Iodo/química , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Humanos , Método de Monte Carlo , Imagens de Fantasmas
8.
Eur J Radiol ; 176: 111537, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38823162

RESUMO

BACKGROUND: The response function of imaging systems is regularly considered to improve the qualified maps in various fields. More the accuracy of this function, the higher the quality of the images. METHODS: In this study, a distinct analytical relationship between full-width at half-maximum (FWHM) value and detector energy thresholds at distinct tube peak voltage of 100 kV has been addressed in X-ray imaging. The outcomes indicate that the behavior of the function is exponential. The relevant cut-off frequency and summation of point spread function S(PSF) were assessed at large and detailed energy ranges. RESULTS: A compromise must be made between cut-off frequency and FWHM to determine the optimal model. By detailed energy range, the minimum and maximum of S(PSF) values were revealed at 20 keV and 48 keV, respectively, by 2979 and 3073. Although the maximum value of FWHM occurred at the energy of 48 keV by 224 mm, its minimum value was revealed at 62 keV by 217 mm. Generally, FWHM value converged to 220 mm and S(PSF) to 3026 with small fluctuations. Consequently, there is no need to increase the voltage of the X-ray tube after the energy threshold of 20 keV. CONCLUSION: The proposed FWHM function may be used in designing the setup of the imaging parameters in order to reduce the absorbed dose and obtain the final accurate maps using the related mathematical suggestions.


Assuntos
Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Intensificação de Imagem Radiográfica/métodos , Humanos , Sensibilidade e Especificidade , Raios X , Algoritmos , Doses de Radiação
9.
Phys Med ; 120: 103324, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38458105

RESUMO

PURPOSE: During any radiological procedure, it is important to know the dose to be-administered to the patient and this can be done by estimating the output of the X-ray tube either with a dosimeter or with a mathematical equation or Monte Carlo simulations. The aim of this work is to develop a new mathematical model equation (NMME) for estimating the output of high-frequency X-ray tubes. METHODS: To achieve this, data collected from ten machines in many regions of Cameroon were used (for nine machines) to build an initial model that does not take into account the anode angle and the tenth machine was used to test the model. Using the SpekCalc software, some simulations were carried out to evaluate the influence of the anode angle. This allowed the NMME to be proposed. RESULTS: The deviations frequencies between 0.65% and 19.61% were obtained by comparing the output values obtained using initial model with the measured values. The statistical hypothesis test showed that the estimated values using initial model and NMME are in agreement with those measured unlike the Kothan and Tungjai model. For the tenth machine, the percentage difference between estimated and measured values is less than 8 %. CONCLUSION: These results show that the proposed model performed better than the previous models. In the absence of a dosimeter, the NMME could be used to estimate the output of high frequency X-ray machines and therefore the radiation doses received by patients during diagnostic X-ray examinations.


Assuntos
Modelos Teóricos , Software , Humanos , Raios X , Fluoroscopia , Radiografia , Método de Monte Carlo , Doses de Radiação
10.
Med Phys ; 51(1): 447-463, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37947472

RESUMO

BACKGROUND: Carbon nanotube-based cold cathode technology has revolutionized the miniaturization of X-ray tubes. However, current applications of these devices required optimization for large, uniform fields with low intensity. PURPOSE: This work investigated the feasibility and radiological characteristics of a novel conical X-ray target optimized for high intensity and high directionality to be used in a compact X-ray tube. METHODS: The proposed device uses an ultrathin, conical tungsten-diamond target that exhibits significant heat loading while maintaining a small focal spot size and promoting forward-directedness of the X-ray field through preferential attenuation of oblique-angled photons. The electrostatic and thermal properties of the theoretical tube were calculated and analyzed using COMSOL Multiphysics software. The production, transport, and calculation of radiological properties associated with the resultant X-ray field were performed using the Geant4 toolkit via its wrapper, TOPAS. RESULTS: Heat transfer analysis of this X-ray tube demonstrated the feasibility of a 200-kV electron beam bombarding the proposed target at a maximum current of 100 mA using a 1-ms symmetric duty cycle. The cathode of the X-ray tube was designed to be segmented into nine switchable electrical segments for modulation of the focal spot size from 0.4- to 10.8-mm. After importing the COMSOL-derived electron beam into TOPAS for X-ray production simulations, radiological analysis of the resultant field demonstrated high levels of intrinsic beam collimation while maintaining high intensity. A maximum dose rate of 17,887 cGy/min was calculated for 1-mm depth in water at 7-cm distance. CONCLUSIONS: The proposed X-ray tube design can create highly directional X-ray fields with superior fluence compared to that of current commercial X-ray tubes of comparable size.


Assuntos
Nanotubos de Carbono , Raios X , Radiografia , Fluoroscopia , Software , Método de Monte Carlo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa