Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 224
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Infect Immun ; : e0017224, 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39207146

RESUMO

Abdominal aortic aneurysm (AAA) is a life-threatening cardiovascular disease that has been linked to gut microbiome dysbiosis. Therefore, this study aims to investigate the effects of Akkermansia muciniphila (Am) on AAA mice and the biomolecules involved. AAA mice were generated using angiotensin II (Ang II), and 16sRNA sequencing was used to identify an altered abundance of microbiota in the feces of AAA mice. Vascular smooth muscle cell (VSMC) markers and apoptosis, and macrophage infiltration in mouse aortic tissues were examined. The abundance of Am was reduced in AAA mouse feces, and endothelial PAS domain-containing protein 1 (EPAS1) was downregulated in AAA mice and VSMC induced with Ang II. Am delayed AAA progression in mice, which was blunted by knockdown of EPAS1. EPAS1 was bound to the Cbp/p300-interacting transactivator 2 (CITED2) promoter and promoted CITED2 transcription. CITED2 reduced VSMC apoptosis and delayed AAA progression. Moreover, EPAS1 inhibited macrophage inflammatory response by promoting CITED2 transcription. In conclusion, gut microbiome dysbiosis in AAA induces EPAS1-mediated dysregulation of CITED2 to promote macrophage inflammatory response and VSMC apoptosis.

2.
J Vasc Surg ; 80(3): 612-620, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38604322

RESUMO

OBJECTIVE: The aim of this study was to update our earlier experience and to evaluate long-term outcomes of chimney endovascular aortic repair performed for selected cases with complex abdominal aortic aneurysm. METHODS: A single-center retrospective cohort study was conducted on 51 consecutive patients who underwent chimney endovascular aortic repair procedure, deemed unfit for open surgical repair and fenestrated endovascular aneurysm repair, from October 2009 to November 2019. Kaplan-Meier analyses were used to assess the estimated overall survival, freedom from aneurysm related mortality, freedom from reintervention, freedom from target vessel instability, and freedom from type Ia endoleaks. RESULTS: Fifty-one patients (mean age, 77.1 ± 7.5 years) with a mean preoperative maximum aneurysm diameter of 74.2 ± 20.1 mm were included. Mean follow-up duration was 48.6 months (range, 0-136 months). Estimated overall survival at 5 and 7 years was 36.3% ± 7.1% and 18.3% ± 6.0%, respectively. Freedom from aneurysm-related mortality was 88.6% ± 4.9% at 7 years. Estimated freedom from type Ia endoleaks at 7 years was 91.8% ± 3.9%. A total of 21 late reinterventions were performed in 17 patients (33%). Most of them were performed to treat type II endoleaks with sac growth (47.6%; n = 10) and type Ib endoleak (23.8%; n = 5). Estimated freedom from reintervention at 7 years was 56.3% ± 7.9%. Estimated freedom from target vessel instability at 7 years was 91.5% ± 4.1%. CONCLUSIONS: The 7-year results of chimney endovascular aortic repair procedures performed in our center confirm the long-term safety and effectiveness of this technique in a series of high-risk patients with large aneurysms. The present study has, to the best of our knowledge, the longest follow-up for patients treated with chimney endovascular aortic repair, and it provides data to the scarce literature on the long-term outcomes of this procedure, showing acceptable to good long-term results.


Assuntos
Aneurisma da Aorta Abdominal , Correção Endovascular de Aneurisma , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular , Endoleak/etiologia , Endoleak/cirurgia , Correção Endovascular de Aneurisma/efeitos adversos , Correção Endovascular de Aneurisma/mortalidade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
J Vasc Surg ; 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39181341

RESUMO

OBJECTIVE: Fenestrated-branched endovascular aortic repair (FB-EVAR) has shown favorable outcomes for repair of complex aneurysms and thoracoabdominal aortic aneurysms. Physician-modified endografting (PMEG) and the Gore thoracoabdominal multibranch endoprosthesis (TAMBE) provide custom and off-the-shelf devices for FB-EVAR, respectively. This study compares the outcomes of TAMBE and PMEG at a single institution. METHODS: A retrospective review of patients who underwent TAMBE as part of the multicenter pivotal trial or PMEG as part of a prospective physician-sponsored investigational device exemption at a single institution between 2020 and 2022 were completed. Patient demographics, characteristics, and perioperative and midterm outcomes were compared. RESULTS: A total of 68 patients were included, with 12 in the TAMBE group and 56 in the PMEG group. Baseline characteristics were comparable between groups. Aneurysm type was most often thoracoabdominal aortic aneurysm in both groups (58% TAMBE and 52% PMEG). TAMBE had a higher rate of upper extremity access (100% vs 63%; P = .013) and longer mean procedure time (247 ± 36 minutes vs 189 ± 49 minutes; P < .001). Other intraoperative metrics were similar between groups. Technical success was 100% in TAMBE and 95% in PMEG (P = .412). There was no 30-day mortality in either group. No major adverse events occurred with TAMBE, whereas in PMEG cases, 2% had respiratory failure, 2% required dialysis, and 4% experienced spinal cord ischemia. Although the overall endoleak rates were similar (50% of TAMBE vs 41% of PMEG; P = .57), type II endoleaks accounted for all of the endoleaks in the TAMBE group, whereas type I or III endoleaks were seen in 11% of PMEG patients. At a median follow-up of 26.7 months for the TAMBE group and 21.2 months for the PMEG group, target vessel instability was seen in 10.4% of TAMBE, and 6.9% of PMEG targeted branches (P = .401). Reintervention was required in 33% of TAMBE patients and 27% of PMEG patients (P = .646). Estimated freedom from reintervention rates at 3 years were similar (56% TAMBE vs 62% PMEG, log-rank P = .910). Freedom from visceral renal target vessel instability at 3 years was 89% for both groups (log-rank P = .459). The Kaplan-Meier 3-year estimated survival was 100% for patients in the TAMBE group and 77% for patients in the PMEG group (log-rank P = .157). CONCLUSIONS: At experienced centers, FB-EVAR can be completed with PMEG or TAMBE with comparable, excellent perioperative and midterm outcomes. Reinterventions are frequently needed for both TAMBE and PMEG.

4.
J Endovasc Ther ; : 15266028241253128, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38733303

RESUMO

OBJECTIVE: The objective was to present our experience on managing mycotic infrarenal abdominal aortic aneurysm (MIAAA) through a retrospective cohort study. METHODS: Data of patients with MIAAA managed in our center from July 2016 to October 2022 were retrospectively analyzed. The diagnosis of MIAAA was made based on: (1) preoperative clinical signs of infection; (2) elevated serologic infection parameters; (3) para-aneurysmal infection features on enhanced computed tomography; and (4) positive blood or tissue cultures. All the patients received standard antibiotic therapy. Surgical management including endovascular aneurysm repair (EVAR), initial EVAR followed by open re-operation, and initial open surgical repair (OSR) were conducted according to disease seriosity, physical condition, and patient's will. Infection index and clinical outcome were evaluated during the follow-up time. RESULTS: A total of 23 patients (21 men; averaged=66.3 years, range=49-79 years) were included, with a mean follow-up time of 19.9 months (range=1-75 months). Bacteria culture from blood or tissue specimen was positive in 15 patients (Salmonella, n=8; Escherichia coli, n=3; methicillin-sensitive Staphylococcus aureus [MSSA], n=1; Klebsiella pneumoniae, n=1; Staphylococcus epidermidis, n=1; Mycobacterium tuberculosis, n=1). Seven patients received OSR as the initial surgical intervention, whereas 14 patients chose EVAR instead. The 2 conservatively managed patients (refused surgery) died within 30 days. The 7 patients who received initial OSR survived till now. Among the 14 patients who underwent initial EVAR, infection deteriorated without exception (14/14, 100%). Three of these patients refused re-operation and died within 6 months. Eleven patients received secondary surgical intervention (10 cases of aneurysm and endograft resection, thorough debridement, subclavian to bi-femoral artery bypass, or in situ aorta reconstruction; 1 case of laparoscopic debridement) and 7 survived the follow-up time. The overall mortality rate was 39.1% (9/23). The mortality rates differed greatly following different intervention methods (merely antibiotic management, 100%; initial open operation, 0%; initial EVAR without secondary operation, 100%; initial EVAR plus secondary operation, 36.4%). CONCLUSIONS: Open surgical repair is still the first choice for hemodynamically stable and low-risk patients. Merely EVAR is related with disastrous results, which should be reserved as a temporary alternative for patients with ruptured aneurysms, hemodynamic instability or high surgical risk, and followed by timely secondary OSR. CLINICAL IMPACT: The management of mycotic or primary-infected aortic aneurysm is challenging; treatment remains controversial. Our center has reviewed our experience over the past 6 years and found that open surgical repair is still the first choice for hemodynamically stable and low-risk patients. Merely endovascular aneurysm repair (EVAR) is related with disastrous results, which should be reserved as a temporary alternative for patients with ruptured aneurysms, hemodynamic instability or high surgical risk, and followed by timely secondary open surgical repair.

5.
Vasc Med ; : 1358863X241253732, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860442

RESUMO

INTRODUCTION: Abdominal aortic aneurysm (AAA) is a growing public health problem, and not all patients have access to surgery when needed. This study aimed to analyze spatiotemporal variations in AAA mortality and surgical procedures in Brazilian intermediate geographic regions and explore the impact of different surgical techniques on operative mortality. METHODS: A retrospective longitudinal study was conducted to evaluate AAA mortality from 2008 to 2020 using space-time cube (STC) analysis and the emerging hot spot analysis tool through the Getis-Ord Gi* method. RESULTS: There were 34,255 deaths due to AAA, 13,075 surgeries to repair AAA, and a surgical mortality of 14.92%. STC analysis revealed an increase in AAA mortality rates (trend statistic = +1.7693, p = 0.0769) and a significant reduction in AAA surgery rates (trend statistic = -3.8436, p = 0.0001). Analysis of emerging hotspots revealed high AAA mortality rates in the South, Southeast, and Central-West, with a reduction in procedures in São Paulo and Minas Gerais States (Southeast). In the Northeast, there were extensive areas of increasing mortality rates and decreasing procedure rates (cold spots). CONCLUSION: AAA mortality increased in several regions of the country while surgery rates decreased, demonstrating the need for implementing public health policies to increase the availability of surgical procedures, particularly in less developed regions with limited access to services.

6.
Biomed Eng Online ; 23(1): 71, 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39054524

RESUMO

BACKGROUND: Personalized modeling is a promising tool to improve abdominal aortic aneurysm (AAA) rupture risk assessment. Computed tomography (CT) and quantitative flow (Q-flow) magnetic resonance imaging (MRI) are widely regarded as the gold standard for acquiring patient-specific geometry and velocity profiles, respectively. However, their frequent utilization is hindered by various drawbacks. Ultrasound is used extensively in current clinical practice and offers a safe, rapid and cost-effective method to acquire patient-specific geometries and velocity profiles. This study aims to extract and validate patient-specific velocity profiles from Doppler ultrasound and to examine the impact of the velocity profiles on computed hemodynamics. METHODS: Pulsed-wave Doppler (PWD) and color Doppler (CD) data were successfully obtained for six volunteers and seven patients and employed to extract the flow pulse and velocity profile over the cross-section, respectively. The US flow pulses and velocity profiles as well as generic Womersley profiles were compared to the MRI velocities and flows. Additionally, CFD simulations were performed to examine the combined impact of the velocity profile and flow pulse. RESULTS: Large discrepancies were found between the US and MRI velocity profiles over the cross-sections, with differences for US in the same range as for the Womersley profile. Differences in flow pulses revealed that US generally performs best in terms of maximum flow, forward flow and ratios between forward and backward flow, whereas it often overestimates the backward flow. Both spatial patterns and magnitude of the computed hemodynamics were considerably affected by the prescribed velocity boundary conditions. Larger errors and smaller differences between the US and generic CFD cases were observed for patients compared to volunteers. CONCLUSION: These results show that it is feasible to acquire the patient-specific flow pulse from PWD data, provided that the PWD acquisition could be performed proximal to the aneurysm region, and resulted in a triphasic flow pattern. However, obtaining the patient-specific velocity profile over the cross-section using CD data is not reliable. For the volunteers, utilizing the US flow profile instead of the generic flow profile generally resulted in improved performance, whereas this was the case in more than half of the cases for the patients.


Assuntos
Aorta Abdominal , Estudos de Viabilidade , Hemodinâmica , Ultrassonografia Doppler , Humanos , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Masculino , Idoso , Feminino , Adulto , Modelos Cardiovasculares , Pessoa de Meia-Idade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Imageamento por Ressonância Magnética , Modelagem Computacional Específica para o Paciente , Velocidade do Fluxo Sanguíneo
7.
Vascular ; : 17085381241273299, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39118329

RESUMO

OBJECTIVE: To assess viability and safety of preemptive treatment of type II endoleak for abdominal aortic aneurysm (AAA) repairs. METHODS: A 69-year-old man with renal fusion (horseshoe kidney) was referred for treatment of a 5.5 cm AAA. His anatomy was suitable for endovascular repair. The risk for type II endoleak was increased because of multiple infrarenal arterial orifices originating within the aneurysm sac. These included an accessory renal artery that supplied the renal isthmus, a patent inferior mesenteric artery, and a pair of large lumbar arteries originating from a single orifice (8 mm) at L3 spinal level. The lumbar orifice was selectively cannulated and occluded with thrombogenic coils 1 week prior to his endovascular aneurysm repair. RESULTS: Aneurysm repair was uneventful with no signs of early or delayed endoleak and long-term follow-up of 5 years. CONCLUSIONS: Preemptive coil embolization of perianeurysmal arteries may be considered as a safe and effective strategy for management of potential type II endoleak.

8.
Vascular ; : 17085381241242859, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38527213

RESUMO

PURPOSE: To describe the off-label use of tapered iliac limbs for the treatment of isolated iliac aneurysms with proximal landing zone significantly larger than distal landing zone. TECHNIQUE: Inversion of a Gore Excluder tapered leg (W. L. Gore & Associates Inc, Flagstaff, Arizona) with a modified upside-down technique is described. The endoprosthesis, with the olive at the tip of the releasing system previously cut, is inserted in a tip-to-tip fashion into a 15 Fr introducer sheath. The graft is released inside the introducer. An 18 Fr introducer sheath is advanced up to the proximal sealing zone. Following the removal of the 18 Fr dilator, the 15 Fr introducer with the pre-released graft is inserted co-axially into the 18 Fr introducer. A pre-cut 15 Fr dilator is brought up to the endograft and used as a pusher. A pull-back maneuver of the co-axial system, countertractioning with the dilator maintained in position, allows the delivery of the endograft. CONCLUSION: This technique might offer a feasible option in case of endovascular exclusion of isolated iliac artery aneurysms with significant landing zone diameter mismatch. Extracorporeal inversion is time-saving and could be safer in terms of graft damage and infection.

9.
Vascular ; : 17085381241273262, 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39132754

RESUMO

BACKGROUND: This study aimed to analyze the effect of proximal neck angulation on the biomechanical indices of abdominal aortic aneurysms (AAA) and to investigate its impact on the risk of AAA rupture. METHODS: CT angiography (CTA) data of patients with AAA from January 2015 to January 2022 were collected. Patients were divided into three groups based on the angle of the proximal neck: Group A (âˆ ß ≤ 30°), Group B (30°<âˆ ß ≤ 60°), and Group C (âˆ ß > 60°). Biomechanical indices related to the rupture risk of AAA were analyzed using computational fluid dynamics modeling (CFD-Post) based on the collected data. RESULTS: Group A showed slight turbulence in the AAA lumen with a mixed laminar flow pattern. Group B had a regular low-speed eddy line characterized by cross-flow dominated by lumen blood flow and turbulence. In Group C, a few turbulent lines appeared at the proximal neck, accompanied by eddy currents in the lumen expansion area following the AAA shape. Significant differences were found in peak wall stress, shear stress, and the maximum blood flow velocity impact among the three groups. The maximum blood flow velocity at the angle of the proximal neck impact indicated the influence of the proximal neck angle on the blood flow state in the lumen. CONCLUSION: As the angle of the proximal neck increased, it caused stronger eddy currents and turbulent blood flow due to a high-speed area near the neck. The region with the largest diameter in the abdominal aortic aneurysm was prone to the highest stress, indicating a higher risk of rupture. The corner of the proximal neck experienced the greatest shear stress, potentially leading to endothelial injury and further enlargement of the aneurysm.

10.
Pol J Radiol ; 89: e420-e427, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39257927

RESUMO

Purpose: The aim of this study was to evaluate the diagnostic accuracy of an artificial intelligence (AI) tool in detecting endoleaks in patients undergoing endovascular aneurysm repair (EVAR) using dual-energy computed tomography angiography (CTA). Material and methods: The study involved 95 patients who underwent EVAR and subsequent CTA follow-up. Dualenergy scans were performed, and images were reconstructed as linearly blended (LB) and 40 keV virtual monoenergetic (VMI) images. The AI tool PRAEVAorta®2 was used to assess arterial phase images for endoleaks. Two experienced readers independently evaluated the same images, and their consensus served as the reference standard. Key metrics, including accuracy, precision, recall, F1 score, and area under the receiver operating characteristic (ROC) curve (AUC), were calculated. Results: The final analysis included 94 patients. The AI tool demonstrated an accuracy of 78.7%, precision of 67.6%, recall of 10 71.9%, F1 score of 69.7%, and an AUC of 0.77 using LB images. However, the tool failed to process 40 keV VMI images correctly, limiting further analysis of these datasets. Conclusions: The AI tool showed moderate diagnostic accuracy in detecting endoleaks using LB images but failed to achieve the reliability needed for clinical use due to the significant number of misdiagnoses.

11.
J Vasc Surg ; 78(4): 929-935.e1, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37330148

RESUMO

OBJECTIVE: There is no proven therapy to reduce growth rates of small- to medium-sized abdominal aortic aneurysms (AAAs). Ex vivo and animal studies have demonstrated that a novel stabilizing agent, 1,2,3,4,6-pentagalloyl glucose (PGG), delivered locally to the aneurysm sac, can bind to elastin and collagen to re-establish strength and resist enzymatic degradation. We aimed to demonstrate that a one-time administration of PGG solution to the aneurysm wall is safe and potentially effective to slow the growth of small- to medium-sized AAAs. METHODS: Patients with small- to medium-sized infrarenal AAAs (maximum diameter <5.5 cm) were recruited. Via transfemoral access, a 14F or 16F dual-balloon delivery catheter was introduced into the aneurysm sac. A single, 3-minute, localized endoluminal infusion of PGG was delivered via a 'weeping' balloon to the aneurysm wall. Independent core laboratory measurements of maximum aneurysm sac diameter and sac volume measurements based on computed tomography angiography (CTA) were used for assessments at 1, 6, 12, 24, and 36 months. The primary endpoints were technical success and safety (major adverse events at 30 days). The secondary endpoint was growth stabilization, defined as freedom from aneurysm sac enlargement (diameter increase >5 mm per year or volume increase of >10% per year). RESULTS: Twenty patients (19 male) were enrolled at five centers from May 2019 to June 2022 (mean age, 67.8 years; range, 50-87 years). All procedures were technically successful. The safety profile was consistent with standard interventional procedures. Four patients demonstrated transient elevations of liver enzymes levels that returned to normal by 30 days with no clinical symptoms. Through November 2022, follow-up CTA data is available on the first 11 patients. The average changes in maximum aneurysm diameter from baseline to 6, 12, 24, and 36 months were 0.2 mm, 1.1 mm, 1.2 mm, and 0.8 mm, respectively, and the average changes in volume were 2.0%, 9.6%, 18.1%, and 11.6%, respectively. At 12 months, none of the aneurysms showed growth >5.0 mm, and three had volume growth >10%. CONCLUSIONS: The early results of this first-in-human, small cohort study demonstrated that a single, localized PGG administration to patients with small- to medium-sized infrarenal AAAs is safe. Longer term follow-up on all 20 treated patients is needed to better assess the potential impact on aneurysm growth.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Projetos Piloto , Estudos de Coortes , Aorta Abdominal , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Tomografia Computadorizada por Raios X , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Prótese Vascular , Desenho de Prótese
12.
J Vasc Surg ; 78(5): 1162-1169.e2, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37453587

RESUMO

OBJECTIVE: Stenting of renal and mesenteric vessels may result in changes in velocity measurements due to arterial compliance, potentially giving rise to confusion about the presence of stenosis during follow-up. The aim of our study was to compare preoperative and postoperative changes in peak systolic velocity (PSV, cm/s) after placement of the celiac axis (CA), superior mesenteric artery (SMA) and renal artery (RAs) bridging stent grafts during fenestrated-branched endovascular aortic repair (FB-EVAR) for treatment of complex abdominal aortic aneurysms (AAA) and thoracoabdominal aortic aneurysms. METHODS: Patients were enrolled in a prospective, nonrandomized single-center study to evaluate FB-EVAR for treatment of complex AAA and thoracoabdominal aortic aneurysms between 2013 and 2020. Duplex ultrasound examination of renal-mesenteric vessels were obtained prospectively preoperatively and at 6 to 8 weeks after the procedure. Duplex ultrasound examination was performed by a single vascular laboratory team using a predefined protocol including PSV measurements obtained with <60° angles. All renal-mesenteric vessels incorporated by bridging stent grafts using fenestrations or directional branches were analyzed. Target vessels with significant stenosis in the preoperative exam were excluded from the analysis. The end point was variations in PSV poststent placement at the origin, proximal, and mid segments of the target vessels for fenestrations and branches. RESULTS: There were 419 patients (292 male; mean age, 74 ± 8 years) treated by FB-EVAR with 1411 renal-mesenteric targeted vessels, including 260 CAs, 409 SMAs, and 742 RAs. No significant variances in the mean PSVs of all segments of the CA, SMA, and RAs at 6 to 8 weeks after surgery were found as compared with the preoperative values (CA, 135 cm/s vs 141 cm/s [P = .06]; SMA, 128 cm/s vs 125 cm/s [P = .62]; RAs, 90 cm/s vs 83 cm/s [P = .65]). Compared with baseline preoperative values, the PSV of the targeted vessels showed no significant differences in the origin and proximal segment of all vessels. However, the PSV increased significantly in the mid segment of all target vessels after stent placement. CONCLUSIONS: Stent placement in nonstenotic renal and mesenteric vessels during FB-EVAR is not associated with a significant increase in PSVs at the origin and proximal segments of the target vessels. Although there is a modest but significant increase in velocity measurements in the mid segment of the stented vessel, this difference is not clinically significant. Furthermore, PSVs in stented renal and mesenteric arteries were well below the threshold for significant stenosis in native vessels. These values provide a baseline or benchmark for expected PSVs after renal-mesenteric stenting during FB-EVAR.

13.
J Vasc Surg ; 78(4): 874-882, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37290733

RESUMO

OBJECTIVE: Staged endovascular repair of complex aortic aneurysms with first-stage thoracic endovascular aortic repair may decrease the risk of spinal cord ischemia (SCI) associated with fenestrated-branched endovascular aortic repair (FB-EVAR) of thoracoabdominal aortic aneurysms or optimize the proximal landing zone in the cases requiring total aortic arch repair. However, a limitation of multistaged procedures is the risk of interval aortic events (IAEs) including mortality from a ruptured aneurysm. We aim to identify the incidence of and risk factors associated with IAEs during staged FB-EVAR. METHODS: This was a single-center, retrospective review of patients who underwent planned staged FB-EVAR from 2013 to 2021. Clinical and procedural details were reviewed. End points were the incidence of and risk factors associated with IAEs (defined as rupture, symptoms, and unexplained death) and outcomes in patients with or without IAEs. RESULTS: Of 591 planned FB-EVAR patients, 142 underwent first-stage repairs. Twenty-two did not have a planned second stage because of frailty, preference, severe comorbidities, or complications after the first stage and were excluded. The remaining 120 patients (mean age: 73 ± 6 years, 51% female) were planned for second-stage completion FB-EVAR and comprised our cohort. The incidence of IAEs was 13% (16 of 120). This included confirmed rupture in 6 patients, possible rupture in 4, symptomatic presentation in 4, and early unexplained interval death with possible rupture in 2. The median time to IAEs was 17 days (range: 2-101 days), and the median time to uncomplicated completion repairs was 82 days (interquartile range: 30-147 days). Age, sex, and comorbidities were similar between the groups. There were no differences in familial aortic disease, genetically triggered aneurysms, aneurysm extent, or presence of chronic dissection. Patients with IAEs had significantly larger aneurysm diameters than those without IAEs (76.6 vs 66.5 mm, P ≤ .001). This difference persisted with indexing for body surface area (aortic size index: 3.9 vs 3.5 cm/m2, P = .04) and height (aortic height index: 4.5 vs 3.9 cm/m, P ≤ .001). IAE mortality was 69% (11 of 16) compared with no perioperative deaths for those with uncomplicated completion repairs. CONCLUSIONS: The incidence of IAEs was 13% in patients planned for staged FB-EVAR. This represented a notable morbidity, including rupture, which must be balanced with SCI and landing zone optimization when planning repair. Larger aneurysms, especially when adjusted for body surface area, are associated with IAEs. Minimizing time between stages vs single-stage repairs for larger (>7 cm) complex aortic aneurysms in patients with reasonable SCI risk should be considered when planning repair.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma Aórtico , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Humanos , Feminino , Idoso , Masculino , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/epidemiologia , Aneurisma da Aorta Torácica/cirurgia , Correção Endovascular de Aneurisma , Incidência , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Fatores de Risco , Aneurisma Aórtico/cirurgia , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/epidemiologia , Isquemia do Cordão Espinal/etiologia , Estudos Retrospectivos
14.
FASEB J ; 36(11): e22579, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36183323

RESUMO

Abdominal aortic aneurysm (AAA) formation is characterized by inflammation, leukocyte infiltration, and vascular remodeling. Resolvin D1 (RvD1) is derived from ω-3 polyunsaturated fatty acids and is involved in the resolution phase of chronic inflammatory diseases. The aim of this study was to decipher the protective role of RvD1 via formyl peptide receptor 2 (FPR2) receptor signaling in attenuating abdominal aortic aneurysms (AAA). The elastase-treatment model of AAA in C57BL/6 (WT) mice and human AAA tissue was used to confirm our hypotheses. Elastase-treated FPR2-/- mice had a significant increase in aortic diameter, proinflammatory cytokine production, immune cell infiltration (macrophages and neutrophils), elastic fiber disruption, and decrease in smooth muscle cell α-actin expression compared to elastase-treated WT mice. RvD1 treatment attenuated AAA formation, aortic inflammation, and vascular remodeling in WT mice, but not in FPR2-/- mice. Importantly, human AAA tissue demonstrated significantly decreased FPR2 mRNA expression compared to non-aneurysm human aortas. Mechanistically, RvD1/FPR2 signaling mitigated p47phox phosphorylation and prevented hallmarks of ferroptosis, such as lipid peroxidation and Nrf2 translocation, thereby attenuating HMGB1 secretion. Collectively, this study demonstrates RvD1-mediated immunomodulation of FPR2 signaling on macrophages to mitigate ferroptosis and HMGB1 release, leading to resolution of aortic inflammation and remodeling during AAA pathogenesis.


Assuntos
Aneurisma da Aorta Abdominal , Ferroptose , Proteína HMGB1 , Actinas/metabolismo , Animais , Aneurisma da Aorta Abdominal/metabolismo , Citocinas/metabolismo , Modelos Animais de Doenças , Ácidos Docosa-Hexaenoicos/metabolismo , Proteína HMGB1/metabolismo , Humanos , Inflamação/metabolismo , Macrófagos/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Fator 2 Relacionado a NF-E2/metabolismo , Elastase Pancreática/metabolismo , RNA Mensageiro/metabolismo , Receptores de Formil Peptídeo/genética , Receptores de Formil Peptídeo/metabolismo , Receptores de Lipoxinas , Remodelação Vascular
15.
J Endovasc Ther ; 30(2): 289-295, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35249413

RESUMO

OBJECTIVE: Symptomatic abdominal aortic aneurysms (sAAA) are considered surgically urgent. Recent data suggest delaying surgery allows for medical optimization without affecting outcomes. We investigated the association of the hospital day of surgery with 30 day outcomes. METHODS: Patients with infrarenal sAAA undergoing endovascular aortic repair (EVAR) between 2011 and 2018 in the American College of Surgeons National Surgery Quality Improvement Project database were included. The primary outcome was 30 day mortality. Additional outcomes included myocardial infarction, pulmonary complications, length of stay, and discharge disposition. Days-to-surgery were classified as the day of presentation (D0), day 1, day 2, days 3 and 4, days 5 to 7 (D5), and day 8 or more (D8). RESULTS: A total of 804 patients were identified. D8 patients had higher proportions of dyspnea on exertion, chronic obstructive pulmonary disease, congestive heart failure, and history of dialysis. D0 surgery appeared protective of mortality (odds ratio [OR] 0.34, p=0.0132). Each additional day increased the mortality risk (OR 1.23, p<0.001) although not within the first 4 days. There was increased mortality for patients having surgery at D5 (7.7%) and D8 (23.8%) compared with repair earlier (1%-4%, p=0.03). Bivariable analysis revealed no significant differences in secondary outcomes. Multivariable modeling revealed increased mortality for D8 versus D0 (adjusted OR of 6.8, 95% confidence interval 1.7-26.5). CONCLUSIONS: While D0 appears to have the lowest risk of mortality, EVAR for sAAA up to 4 days may not be associated with increased mortality. Further research should determine delay etiologies and whether they improve operative planning and optimization without impacting morbidity and mortality.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Hospitais , Complicações Pós-Operatórias , Estudos Retrospectivos , Medição de Risco
16.
Eur J Vasc Endovasc Surg ; 66(3): 418-427, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36963747

RESUMO

OBJECTIVE: This study proposed a method for semi-automatic segmentation of abdominal aortic aneurysms (AAAs) and their intraluminal thrombus (ILT), based on time resolved 3D ultrasound (US), and validated results with computed tomography (CT). Mechanical properties of both wall and ILT were determined, and possible correlations with ILT size and blood pressure were investigated. METHODS: A semi-automatic segmentation algorithm was developed combining a star-Kalman approach with a 3D snake algorithm. The segmented geometries of both lumen and inner vessel wall were validated with both manual US based segmentations and CT based segmentations. Finally, the lumen and vessel wall distensibility and ILT compressibility were estimated and correlated with ILT size and blood pressure. RESULTS: For the vessel wall and lumen, the median Similarity Index (SI) was 92% (IQR 90, 94%) and 83% (IQR 75, 87%), respectively. The distensibility of the vessel wall could be determined in 37 of 40 cases and had a median value of 0.28 10-5 Pa-1 (IQR 0.18, 0.51 ×10-5). The median systolic to diastolic volume change of the ILT was determined successfully in 21 of 40 patients, and was -0.57% (IQR -1.1, 1.2%). The vessel and lumen distensibility showed a strong correlation with the systolic pressure (p < .010), rather than with the diastolic pressure. Lumen distensibility was strongly correlated with ILT thickness (p = .023). The performance of the semi-automatic segmentation algorithm was shown to be as good as the manual segmentations and highly dependent on the visibility of the ILT (limited contrast in seven patients and clutter in nine patients). CONCLUSION: This study has shown promising results for mechanical characterisation of the vessel, and ILT, including a correlation between distensibility, ILT size, and blood pressure. For future work, the inclusion rate needs to be increased by improving the image contrast with novel US techniques.


Assuntos
Aneurisma da Aorta Abdominal , Trombose , Humanos , Angiografia por Tomografia Computadorizada , Aneurisma da Aorta Abdominal/cirurgia , Aorta Abdominal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Trombose/diagnóstico por imagem
17.
Eur J Vasc Endovasc Surg ; 65(6): 896-904, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36921753

RESUMO

OBJECTIVE: The aim of this study was to describe and present the outcomes of a specific treatment protocol for aortic vascular graft and endograft infections (VGEIs) without explantation of the infected graft. METHODS: This was a retrospective, observational single centre cohort study carried out between 2012 and 2022 at a tertiary hospital. An aortic VGEI was defined according to the Management of Aortic Graft Infection Collaboration (MAGIC) criteria. Fitness for graft excision was assessed by a multidisciplinary team and included an evaluation of the patient's general condition, septic status, and anatomical complexity. Antimicrobial treatments were individualised. The primary outcome was survival at the last available follow up; secondary outcomes were antimicrobial treatment duration, infection eradication, treatment failure despite antimicrobial treatment, and the development of aortic fistulation. RESULTS: Fifty patients were included in the study, of whom 42 (84%) had had previous endovascular repair. The median patient age was 72 years (range 51 - 82 years) and median duration of treatment with antimicrobials was 18 months (range 1 - 164 months). Kaplan-Meier analysis estimated the 30 day survival to be 98% (95% confidence interval [CI] 96 - 100), the one year survival rate to be 88% (95% CI 83.4 - 92.6), and the three year survival rate to be 79% (95% CI 72.7 - 84.7). Twenty-four (48%) patients were able to discontinue antibiotic treatment after a median of 16 months (range 4 - 81 months). When categorised according to infected graft location, deaths occurred in four (40%) patients with thoracic, two (40%) with paravisceral, seven (30%) with infrarenal VGEIs, and in one (25%) patient with an aorto-iliac VGEI; no (0%) patient with a thoraco-abdominal VGEI died. CONCLUSION: Identifying the microbiological aetiology in patients with aortic VGEI enables individualised, specific antibiotic treatment, which may be useful in patients with a VGEI excluded from surgery. This single centre retrospective analysis of patients with VGEIs without fistula selected for conservative treatment suggests that conservative management of aortic VGEIs with targeted antibiotic therapy without graft excision is potentially effective, and that antimicrobial treatment will not necessarily be needed indefinitely.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Infecções Relacionadas à Prótese , Humanos , Pré-Escolar , Criança , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Tratamento Conservador/efeitos adversos , Estudos Retrospectivos , Estudos de Coortes , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/cirurgia , Antibacterianos/uso terapêutico , Aneurisma da Aorta Abdominal/cirurgia , Fatores de Risco
18.
Mol Divers ; 2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37653360

RESUMO

Abdominal aortic aneurysms (AAA) is a life-threatening disease and the incidence of AAA is still on the rise in recent years. Numerous studies suggest that dietary moderate consumption of polyphenol exerts beneficial effects on cardiovascular disease. Apigenin (API) is a promising dietary polyphenol and possesses potent beneficial effects on our body. Although our previous study revealed protective effects of API on experimental AAA formation, up till now few studies were carried out to further investigate its involved molecular mechanisms. In the present study, network pharmacology combined molecular docking and experimental validation was used to explore API-related therapeutic targets and mechanisms in the treatment of AAA. Firstly, we collected 202 API-related therapeutic targets and 2475 AAA-related pathogenetic targets. After removing duplicates, a total of 68 potential therapeutic targets were obtained. Moreover, 5 targets with high degree including TNF, ACTB, INS, JUN, and MMP9 were identified as core targets of API for treating AAA. In addition, functional enrichment analysis indicated that API exerted pharmacological effects in AAA by affecting versatile mechanisms, including apoptosis, inflammation, blood fluid dynamics, and immune modulation. Molecular docking results further supported that API had strong affinity with the above core targets. Furthermore, protein level of core targets and related pathways were evaluated in a Cacl2-induced AAA model by using western blot and immunohistochemistry. The experimental validation results demonstrated that API significantly attenuated phosphorylation of JUN and protein level of predicted core targets. Taken together, based on network pharmacological and experimental validation, our study systematically explored associated core targets and potential therapeutic pathways of API for AAA treatment, which could supply valuable insights and theoretical basis for AAA treatment.

19.
Vascular ; 31(3): 409-416, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35687809

RESUMO

OBJECTIVES: To develop a prediction model that could risk stratify abdominal aortic aneurysms (AAAs) into high and low growth rate groups, using machine learning algorithms based on variables from different pathophysiological fields. METHODS: A cohort of 40 patients with small AAAs (maximum diameter 32-53 mm) who had at least an initial and a follow-up CT scan (median follow-up 12 months, range 3-36 months) were included. 29 input variables from clinical, biological, morphometric, and biomechanical pathophysiological aspects extracted for predictive modeling. Collected data were used to build two supervised machine learning models. A gradient boosting (XGboost) and a support vector machines (SVM) algorithm were trained with 60% and tested with 40% of the data to predict which AAA would achieve a growth rate higher than the median of our study cohort. Receiver operating characteristics (ROC) curves and areas under the curve (AUC) were used for the evaluation of the developed algorithms. RESULTS: XGboost achieved the highest AUC in predicting high compared to low AAA growth rate with an AUC of 81.2% (95% CI from 61.1 to 100%). SVM achieved the second highest performance with an AUC of 68.8% (95% CI from 46.5 to 91%). Based on the best performing algorithm, variable importance was estimated. Diameter-diameter ratio (maximum diameter/neck diameter), Tortuosity from Renal arteries to aortic bifurcation, and maximum thickness of the intraluminal thrombus were found to be the most important factors for model predictions. Other factors were also found to play a significant but less important role. CONCLUSIONS: A prediction model that can risk stratify AAAs into high and low growth rate groups could be developed by analyzing several factors implicated in the multifactorial pathophysiology of this disease, with the use of machine learning algorithms. Future studies including larger patient cohorts and implementing additional risk markers may aid in the establishment of such methodology during AAA rupture risk estimation.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Produtos Biológicos , Humanos , Inteligência Artificial , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal , Tomografia Computadorizada por Raios X , Fatores de Risco
20.
Vascular ; 31(6): 1051-1060, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35578179

RESUMO

BACKGROUND: A considerable number of patients with abdominal aortic aneurysms (AAA) is not eligible for standard endovascular repair. These complex cases require alternative surgical approaches including the readily available chimney graft endovascular aneurysm repair (Ch-EVAR) or sealing (Ch-EVAS). The optimal configuration for Ch-EVAR or Ch-EVAS is important for success but not yet known. OBJECTIVE: The aim of the present study was to analyze current data of the outcomes of in-vitro chimney graft treatment in complex AAA. METHODS: A systematic review following PRISMA guidelines was conducted including studies reporting on gutter size, main graft compression, and chimney graft compression in in-vitro configurations. RESULTS: The search resulted in 285 articles. 11 studies considering 219 individual tests could be included. Gutter size was comparable between Ch-EVAR and Ch-EVAS configurations. In Ch-EVAR set-ups, the deployed BECG were Advanta V12, VIABAHN®, and BeGraft. One type of SECG was used: VIABAHN®. The four types of main grafts (MG) deployed were: Endurant™ I/II; EXCLUDER Conformable AAA Endoprosthesis and AAA Endoprosthesis, and AFX™ Endovascular AAA Delivery System. In the EVAS-configurations, the Nellix® EVAS system was deployed. In general, SECG presented smaller gutters with higher chimney graft compression. 30% main grafts oversizing seems to give the smallest gutters without high risk of infolding of MG. Oversizing, EndoAnchors, and secondary endobag filling (in Ch-EVAS) reduced gutter sizes. CG ballooning during the entire polymer injection in Ch-EVAS prevented CG compression. CONCLUSION: In-vitro investigations provide insight in optimal Ch-EVAR and Ch-EVAS configurations for simulated complex AAA repair. The findings above might aid physicians in their planning to potential CG set-ups and can be used in future research to refine the most optimal configuration for chimney graft technique in complex AAA.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Procedimentos Endovasculares/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Aprendizagem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa