Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Sensors (Basel) ; 23(19)2023 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-37837130

RESUMO

In order to investigate the factors affecting the acoustic performance of the extrinsic Fabry-Perot interferometer (EFPI) fiber-optic acoustic pressure sensor and to effectively improve its detection capability, this paper enhances the sensor's detection sensitivity by adding more sensitized rings to its acoustic pressure-sensitive film. Furthermore, a novel real-time coupled acoustic test method is proposed to simultaneously monitor the changes in the spectral and acoustic metrics of the sensor to characterize its overall performance. Finally, an EFPI-type fiber-optic acoustic pressure sensor was developed based on the Micro-Optical Electro-Mechanical System (MOEMS). The acoustic tests indicate that the optimized fiber-optic acoustic pressure sensor has a sensitivity as high as 2253.2 mV/Pa, and the acoustic overload point (AOP) and signal-to-noise ratios (SNRs) can reach 108.85 dB SPL and 79.22 dB, respectively. These results show that the sensor produced through performance characterization experiments and subsequent optimization has a very high acoustic performance index, which provides a scientific theoretical basis for improving the overall performance of the sensor and will have broad application prospects in the field of acoustic detection.

2.
Small ; 18(22): e2108040, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35499188

RESUMO

Ultrasound molecular imaging (UMI) has shown promise for assessing the expression levels of biomarkers for the early detection of various diseases. However, it remains difficult to simultaneously image multiple biomarkers in a single systemic administration, which is important for the accurate diagnosis of diseases and for understanding the dynamic intermolecular mechanisms that drive their malignant progression. The authors develop an ultrasound molecular imaging method by serial collapse of targeting microbubbles with distinct acoustic pressures for the simultaneous detection of two biomarkers. To test this, αv ß3 -targeting lipid microbubbles (L-MBα ) and VEGFR2-targeting lipid-PLGA microbubbles (LP-MBv ) are fabricated and simultaneously injected into tumor-bearing mice at 7 and 14 days, followed by the low-intensity acoustic collapse of L-MBα and high-intensity acoustic collapse of LP-MBv . The UMI signals of L-MBα and LP-MBv are obtained by subtracting the first post-burst signals from the first pre-burst signals, and subtracting the second post-burst signals from the first post-burst signals, respectively. Interestingly, the signal intensities from UMI agree with the immunohistochemical staining results for αv ß3 and VEGFR2. Importantly, they find a better fit for the invasive behavior of MDA-MB-231 breast tumors by analyzing the ratio of αv ß3 integrin to VEGFR2, but not the single αv ß3 or VEGFR2 levels.


Assuntos
Meios de Contraste , Microbolhas , Acústica , Animais , Biomarcadores , Meios de Contraste/metabolismo , Lipídeos , Camundongos , Imagem Molecular/métodos , Neovascularização Patológica/metabolismo , Ultrassonografia/métodos
3.
Sensors (Basel) ; 22(9)2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35591053

RESUMO

The study investigates the effect of changing various input parameters on the pressure responses at acoustic cavities of a droplet-based acoustic printing device consisting of a Fabry-Pérot (FP) resonator and a standing wave-source chamber. The standing wave of the acoustic radiation pressure at the FP resonator is analyzed. The behavior of the standing wave and acoustic radiation force at the FP resonator is presented and compared with the measured results by varying the position of the standing wave-generating plate. The pressure changes inside the standing wave-source chamber are investigated and discussed to determine the reason for the sudden high-pressure drop at the FP resonator. Furthermore, the effects of inserting the nozzle and droplet inside the FP resonator on the standing wave and acoustic radiation force are analyzed. Experimental analysis is performed by collecting acoustic pressure data at the outlet of the FP resonator. The simulated and measured pressure drop behaviors are compared. The presented numerical approach can be used to set optimal design guidelines for obtaining a higher acoustic pressure inside the acoustic cavities of droplet-based acoustic jetting and other acoustofluidic devices.

4.
Sensors (Basel) ; 22(14)2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-35891023

RESUMO

Scholte waves at the seafloor have significant potential for underwater detection and communication, so a study about detecting Scholte waves is very meaningful in practice. In this paper, the detection of Scholte waves at the seafloor is researched theoretically and experimentally. Acoustic models with the multilayer elastic bottom are established according to the ocean environment, and a tank experiment is designed and carried out to detect Scholte waves. Different from detecting Scholte waves in the seismic wavefield, a technique for detecting Scholte waves in the sound pressure field is proposed in this paper. The experimental results show that the proposed technique can detect Scholte waves effectively, and there are no problems such as seabed coupling and the effect of wave speeds. Furthermore, the results also show that this detection technique is still effective in conditions with a sediment layer. The existence of sediment layers changes the acoustic field conditions and affects the excitation of Scholte waves.


Assuntos
Acústica , Som
5.
Sensors (Basel) ; 22(23)2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-36501852

RESUMO

With the development of technology, systems gravitate towards increasing in their complexity, miniaturization, and level of automation. Amongst these systems, ultrasonic devices have adhered to this trend of advancement. Ultrasonic systems require transducers to generate and sense ultrasonic signals. These transducers heavily impact the system's performance. Advancements in microelectromechanical systems have led to the development of micromachined ultrasonic transducers (MUTs), which are utilized in miniaturized ultrasound systems. Piezoelectric micromachined ultrasonic transducers (PMUTs) exhibit higher capacitance and lower electrical impedance, which enhances the transducer's sensitivity by minimizing the effect of parasitic capacitance and facilitating their integration with low-voltage electronics. PMUTs utilize high-yield batch microfabrication with the use of thin piezoelectric films. The deposition of thin piezoelectric material compatible with complementary metal-oxide semiconductors (CMOS) has opened novel avenues for the development of miniaturized compact systems with the same substrate for application and control electronics. PMUTs offer a wide variety of applications, including medical imaging, fingerprint sensing, range-finding, energy harvesting, and intrabody and underwater communication links. This paper reviews the current research and recent advancements on PMUTs and their applications. This paper investigates in detail the important transduction metrics and critical design parameters for high-performance PMUTs. Piezoelectric materials and microfabrication processes utilized to manufacture PMUTs are discussed. Promising PMUT applications and outlook on future advancements are presented.


Assuntos
Sistemas Microeletromecânicos , Transdutores , Desenho de Equipamento , Ultrassom , Ultrassonografia/métodos
6.
Sensors (Basel) ; 21(4)2021 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-33670248

RESUMO

The paper tackles the issues of data acquisition during the measuring of vibrations caused by the detonation of explosive charges in various types of works (blasting in mines, demolition works, tunneling). Depending on the placement of an explosive charge (a charge detonated on the surface or a charge placed in a hole), it triggers side effects in the form of mechanical vibrations, which are propagated in the environment and may pose a hazard to buildings. In the case of propagation in the air, there is an acoustic wave and an airblast wave. For the assessment analysis on the impact of vibrations on buildings, a ground-propagated signal is used, while what is propagated by air is a disturbance. Selected examples in the paper demonstrate how an acoustic wave and an airblast wave interferes with the signal recorded by geophones. Afterwards, the paper presents the results of the tests conducted at a training area, during which various masses of explosive charges placed in different ways were detonated. The examples demonstrate that this interference may lead to the misinterpretation of recorded measurements. This paper is the first of two papers that will present the results of research into this matter and the suggested resolutions in order to eliminate this interference.

7.
Sensors (Basel) ; 20(11)2020 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-32531993

RESUMO

Through-metal transfer of energy and data using piezoelectric transduce can avoid the potential leakage problem caused by physical penetrations and wired feed-through. The through-metal transfer efficiency of energy or data is determined by the relative pressure on the receiving PZT (piezoelectric transducer). Hence, in this paper, we first propose the Spatial Equivalent Plane Acoustic Pressure (SEPAP), which is defined as the integration of the acoustic pressure over the receiving area, to model the pressure on the receiving PZT. Then we analyze the features of SEPAP and the factors impacting it by utilizing COMSOL. Furthermore, we propose a low-cost and small-size prototype for simultaneous transfer of energy and bidirectional communication through metal by using two pairs of PZTs working on different resonant frequencies. Extensive experiment has been done on evaluating the match between SEPAP transfer efficiency and the power transfer efficiency and analyzing the achievable data rate for bi-directional communication. Test through a 20 mm aluminum alloy plate shows that power transmission with efficiency 20.3% and data communication rate up to 38.4 Kbps can be achieved simultaneously.

8.
Sensors (Basel) ; 18(6)2018 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-29895765

RESUMO

High-frequency unfocused polymer array transducers are developed using an adhesive-free layer-by-layer assembly method. The current paper focuses on experimental and numerical methods for measuring the acoustic performance of these types of array transducers. Two different types of numerical approaches were used to simulate the transducer performance, including a finite element method (FEM) study of the transducer response done in COMSOL 5.2a Multiphysics, and modeling of the excited ultrasonic pressure fields using the open source software k-Wave 1.2.1. The experimental characterization also involves two methods (narrow and broadband pulses), which are measurements of the acoustic reflections picked up by the transducer elements. Later on, measurements were undertaken of the ultrasonic pressure fields in a water-scanning tank using a hydrophone system. Ultrasonic pressure field measurements were visualized at various distances from the transducer surface and compared with the numerical findings.

9.
Sensors (Basel) ; 17(5)2017 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-28481297

RESUMO

A flexible acoustic pressure sensor was developed based on the change in electrical resistance of three-dimensional (3D) graphene change under the acoustic waves action. The sensor was constructed by 3D graphene foam (GF) wrapped in flexible polydimethylsiloxane (PDMS). Tuning forks and human physiological tests indicated that the acoustic pressure sensor can sensitively detect the deformation and the acoustic pressure in real time. The results are of significance to the development of graphene-based applications in the field of health monitoring, in vitro diagnostics, advanced therapies, and transient pressure detection.

10.
Adv Exp Med Biol ; 875: 363-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26610980

RESUMO

In this paper, we discuss the issues encountered when trying to perform hearing experiments in water-filled tanks that are several meters in lateral extent, typically large in terms of the size of the animals under study but not necessarily so with respect to the wavelengths of interest. This paper presents measurements of pressure and particle motion fields in these "large" tanks. The observed characteristics and complexities are discussed in reference to their potential impact on the planning and interpretation of hearing experiments.


Assuntos
Acústica , Pesqueiros , Animais , Peixes , Pressão
11.
Adv Exp Med Biol ; 875: 461-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26610992

RESUMO

Playbacks are a useful tool for conducting well-controlled and replicated experiments on the effects of anthropogenic noise, particularly for repeated exposures. However, playbacks are unlikely to fully reproduce original sources of anthropogenic noise. Here we examined the sound pressure and particle acceleration of boat noise playbacks in a field experiment and reveal that although there remain recognized limitations, the signal-to-noise ratios of boat playbacks to ambient noise do not exceed those of a real boat. The experimental setup tested is therefore of value for use in experiments on the effects of repeated exposure of aquatic animals to boat noise.


Assuntos
Estimulação Acústica , Exposição Ambiental , Ruído , Gravação em Fita , Animais , Navios
12.
Ultrasound Med Biol ; 50(9): 1415-1425, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38879428

RESUMO

OBJECTIVE: We propose an ultrasonic treatment for collagenase-induced tendinopathy in rat's Achilles tendon using pulses with a low number of cycles, high acoustic pressure and very low duty cycle. METHODS: Twenty rats were used to perform the experiment. Four experimental groups of calcaneal tendons were studied: control (n = 6), sham (n = 4), collagenase-induced tendinopathy (n = 8) and ultrasound-treated collagenase-induced tendinopathy (n = 8). Surgical intervention was performed to expose the tendons prior to collagenase injection. A 1 MHz ultrasonic tansducer with a focusing lens was used. Ultrasonic treatments were used with an average total treatment time of 2.5 min, 20-cycle pulses, pressure amplitude p = 7 MPa, and 0.02% duty cycle. Histopathology of the samples was performed to evaluate nuclear density, acute inflammation, and signs of neovascularization. Collagen (types I and III), elastic fibers, and glycosaminoglycans were also analyzed. RESULTS: No tendon involvement was found by the surgical process. Ultrasonic treatment is safe, as it does not affect healthy tendons. When collagenase infiltrated animals were treated with US, a clear predominance of type I collagen fibers and a similar collagen ratio profile to that observed in the control and sham groups was observed, with a higher density of elastic fibers compared to the control and sham groups and a significant increase in the density of glycosaminoglycans. CONCLUSION: The ultrasound treatment proposed reduces the effects of the artificial collagenase lesion to reach the basal level after 45 d.


Assuntos
Tendão do Calcâneo , Colagenases , Tendinopatia , Terapia por Ultrassom , Animais , Tendão do Calcâneo/lesões , Tendinopatia/terapia , Ratos , Terapia por Ultrassom/métodos , Modelos Animais de Doenças , Masculino , Resultado do Tratamento , Ratos Wistar , Ratos Sprague-Dawley , Pressão
13.
Ultrason Sonochem ; 102: 106721, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38103370

RESUMO

Most ultrasound-based processes root in empirical approaches. Because nearly all advances have been conducted in aqueous systems, there exists a paucity of information on sonoprocessing in other solvents, particularly ionic liquids (ILs). In this work, we modelled an ultrasonic horn-type sonoreactor and investigated the effects of ultrasound power, sonotrode immersion depth, and solvent's thermodynamic properties on acoustic cavitation in nine imidazolium-based and three pyrrolidinium-based ILs. The model accounts for bubbles, acoustic impedance mismatch at interfaces, and treats the ILs as incompressible, Newtonian, and saturated with argon. Following a statistical analysis of the simulation results, we determined that viscosity and ultrasound input power are the most significant variables affecting the intensity of the acoustic pressure field (P), the volume of cavitation zones (V), and the magnitude of the maximum acoustic streaming surface velocity (u). V and u increase with the increase of ultrasound input power and the decrease in viscosity, whereas the magnitude of negative P decreases as ultrasound power and viscosity increase. Probe immersion depth positively correlates with V, but its impact on P and u is insignificant. 1-alkyl-3-methylimidazolium-based ILs yielded the largest V and the fastest acoustic jets - 0.77 cm3 and 24.4 m s-1 for 1-ethyl-3-methylimidazolium chloride at 60 W. 1-methyl-3-(3-sulfopropyl)-imidazolium-based ILs generated the smallest V and lowest u - 0.17 cm3 and 1.7 m s-1 for 1-methyl-3-(3-sulfopropyl)-imidazolium p-toluene sulfonate at 20 W. Sonochemiluminescence experiments validated the model.

14.
Ultrason Sonochem ; 108: 106954, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38879962

RESUMO

In this work, we implement a dual frequency (24 kHz and 1174 kHz) ultrasonic assisted liquid phase exfoliation (ULPE) technique in deionized water (DIW) and other eco-friendly solvents, to produce a variety of high-quality few-layer graphene (FLG) solutions under controlled ultrasonication conditions. The resulting FLG dispersions of variable sizes (∼0.2-1.5 µm2) confirmed by characterisation techniques comprising UV-Vis spectroscopy, Raman spectroscopy and high-resolution transmission electron microscopy (HR-TEM). For the first time we demonstrate that high yield of FLG flakes with minimal defects, stable for 6 + months in a solution (stability âˆ¼ 70 %), can be obtained in less than 1-hour of treatment in either water/ethanol (DIW:EtOH) or water/isopropyl alcohol (DIW:IPA) eco-friendly mixtures. We also scrutinized the underlying mechanisms of cavitation using high-speed imaging synchronized with acoustic pressure measurements. The addition of ethanol or IPA to deionized water is proposed to play a central role in exfoliation as it regulates the extend of the cavitation zone, the intensity of the ultrasonic field and, thus, the cavitation effectiveness. Our study revealed that lateral sizes of the obtained FLG depend on the choice of exfoliating media and the diameter of a sonotrode used. This variability offers flexibility in producing FLG of different sizes, applicable in a wide spectrum of size-specific applications.

15.
Ultrasonics ; 138: 107267, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38367402

RESUMO

Ultrasonic standing waves with specific wavelengths generated in the multi-layered micro-resonators were numerically and experimentally analyzed. Using a three-dimensional scanning fluorescence microscope, the acoustophoretic motion of fluorescent microparticles within the micro-resonators was carefully and accurately measured. The manufactured micro-resonators were validated by comparing the location of the acoustic pressure nodal plane and the average energy density curves derived from numerical and experimental results. Results confirmed that the acoustic radiation force of the induced ultrasonic standing waves drives the microparticles vertically within the micro-resonators and their average energy density increases as the sinusoidal voltage applied to the piezoelectric transducer increases. Semi-empirical correlations were developed for the average energy density, based on experimental results for a wide range of the applied voltage amplitudes. The correlations were in good agreement, within less than 20 % of the experimental values measured for both the half-wavelength and quarter-wavelength micro-resonators.

16.
Ultrasonics ; 128: 106888, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36402114

RESUMO

BACKGROUND: Ultrasound neurostimulation (USNS) is a non-invasive neuromodulation technique that might hold promise for treating neuropsychiatric disorders with regards to its noninvasiveness, penetration depth, and high resolution. OBJECTIVE: We sought in this experimental study to provide detailed and optimized protocol and methodology for a successful ultrasonic neurostimulation of the Primary Motor Cortex (M1) in mice addressed to young researchers/students beginning their research in the field of ultrasonic neurostimulation and encountering practical challenges. METHODS: A 500 kHz single-element transducer was used for stimulating the primary motor cortex at different acoustic pressures in C57BL/6 mice at various anesthesia levels. To further illustrate the effect of anesthesia, real time visual observations of motor responses validated with video recordings as well as electromyography were employed for evaluating the success and reliability of the stimulations. RESULTS: Detailed experimental procedure for a successful stimulations including targeting and anesthesia is presented. Our study demonstrates that we can achieve high stimulation success rates (91 % to 100 %) at acoustic pressures ranging from 330 kPa to 550 kPa at anesthesia washout period. CONCLUSIONS: This study shows a reliable and detailed methodology for successful USNS in mice addressed to beginners in ultrasonic brain stimulation topic. We showed an effective USNS protocol. We offered a simple and consistent non-invasive technique for locating and targeting brain zones. Moreover, we illustrated the acoustic pressure and stimulation success relationship and focused on the effect of anesthesia level for successful stimulation.


Assuntos
Córtex Motor , Animais , Camundongos , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes , Ultrassom , Acústica
17.
Bioeng Transl Med ; 8(2): e10438, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36925707

RESUMO

Conventional 3D cell culture methods require a comprehensive complement in labor-intensive and time-consuming processes along with in vivo circumstantial mimicking. Here, we describe a subaqueous free-standing 3D cell culture (FS) device that can induce the omnidirectional environment and generate ultrafast human adipose-derived stem cells (hADSCs) that efficiently aggregate with compaction using acoustic pressure. The cell culture conditions were optimized using the FS device and identified the underlying molecular mechanisms. Unique phenomena in cell aggregation have led to extraordinary cellular behavior that can upregulate cell compaction, mechanosensitive immune control, and therapeutic angiogenesis. Therefore, we designated the resulting cell aggregates as "pressuroid." Notably, external acoustic stimulation produced by the FS device affected the pressuroids. Furthermore, the pressuroids exhibited upregulation in mechanosensitive genes and proteins, PIEZO1/2. CyclinD1 and PCNA, which are strongly associated with cell adhesion and proliferation, were elevated by PIEZO1/2. In addition, we found that pressuroids significantly increase angiogenic paracrine factor secretion, promote cell adhesion molecule expression, and enhance M2 immune modulation of Thp1 cells. Altogether, we have concluded that our pressuroid would suggest a more effective therapy method for future cell therapy than the conventional one.

18.
Ultrason Sonochem ; 82: 105893, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34969000

RESUMO

The cavitation characteristics during the spreading of a pure Sn liquid droplet subjected to ultrasonication were studied for the first time through high-speed photography to reveal the wetting mechanism. Ultrasonic vibration realized the spreading of Sn droplet on the nonwetting pure Al substrate. However, the oxide layer of the substrate at the spreading front is difficult to remove. The high-speed photography result shows that a noncavitation region consistently appears at the spreading front, because the acoustic pressure is below the cavitation threshold of 1.26 MPa. In particular, the width of the noncavitation region gradually increases as the size of the spreading area increases. Such a result accounts for the condition wherein the oxide layer at the spreading front is difficult to remove. Furthermore, the bubble density during spreading gradually decreases due to the decreased acoustic pressure of the thinned liquid. Finally, the bubble dynamics were calculated to verify the wetting mechanism.

19.
Ultrasound Med Biol ; 48(5): 933-944, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35272891

RESUMO

Ultrasound facilitates the penetration of macromolecular compounds through the skin and offers a promising non-invasive technique for transdermal delivery. However, technical difficulties in quantifying ultrasound-related parameters have restricted further analysis of the sonophoresis mechanism. In this study, we devise a bolt-clamped Langevin transducer-based sonophoresis device that enables us to measure with a thin lead zirconate titanate (PZT) sensor. One-dimensional acoustic theory accounting for wave interaction at the skin interface indicates that the acoustic pressure and cavitation onset on the skin during sonophoresis are sensitive to the subcutaneous support, meaning that there is a strong need to perform the pressure measurement in an experimental environment replacing the human body. From a series of the experiments with our new device, the transdermal penetration of polystyrene, silica and gold nanoparticles is found to depend on the size and material of the particles, as well as the hardness of the subcutaneous support material. We speculate from the acoustic pressure measurement that the particles' penetration results from the mechanical action of cavitation.


Assuntos
Nanopartículas Metálicas , Absorção Cutânea , Acústica , Administração Cutânea , Ouro/metabolismo , Humanos , Pele/metabolismo , Ultrassom/métodos
20.
Ultrason Sonochem ; 82: 105844, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34965507

RESUMO

Microbubbles are widely used in medical ultrasound imaging and drug delivery. Many studies have attempted to quantify the collapse pressure of microbubbles using methods that vary depending on the type and population of bubbles and the frequency band of the ultrasound. However, accurate measurement of collapse pressure is difficult as a result of non-acoustic pressure factors generated by physical and chemical reactions such as dissolution, cavitation, and interaction between bubbles. In this study, we developed a method for accurately measuring collapse pressure using only ultrasound pulse acoustic pressure. Under the proposed method, the collapse pressure of a single hollow glass microsphere (HGM) is measured using a high-frequency (20-40 MHz) single-beam acoustic tweezer (SBAT), thereby eliminating the influence of additional factors. Based on these measurements, the collapse pressure is derived as a function of the HGM size using the microspheres' true density. We also developed a method for estimating high-frequency acoustic pressure, whose measurement using current hydrophone equipment is complicated by limitations in the size of the active aperture. By recording the transmit voltage at the moment of collapse and referencing it against the corresponding pressure, it is possible to estimate the acoustic pressure at the given transmit condition. These results of this study suggest a method for quantifying high-frequency acoustic pressure, provide a potential reference for the characterization of bubble collapse pressure, and demonstrate the potential use of acoustic tweezers as a tool for measuring the elastic properties of particles/cells.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa