1.
BMC Oral Health ; 24(1): 822, 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39033294

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effect of in-vivo produced Nisin which is an antimicrobial peptide (AMP) added to adhesive resin on shear bond strength (SBS) and the adhesive remnant index (ARI) of orthodontic brackets. METHODS: Bacterial AMP was produced by fermentation and the ideal AMP/Bond concentration and antimicrobial efficacy of the mixture were tested. To evaluate the SBS and ARI scores of AMP-added adhesive resins, 80 maxillary premolar teeth extracted for orthodontic purposes were used and randomly assigned into 2 groups (n = 40). Group 1: Control Group (teeth bonded with standard adhesive resin); Group 2: Experimental Group (teeth bonded with AMP-added adhesive resin). Statistical analysis was performed using the SPSS package program and applying the Mann-Whitney U and Fisher's exact tests. P < 0.05 was considered as statistically significant. RESULTS: Nisin synthesized in-vivo from Lactococcus lactis (L. lactis) (ATCC 7962) bacteria was provided to form a homogenous solution at an ideal concentration To find the minimum AMP/Bond mixture ratio that showed maximum antimicrobial activity, AMP and Bond mixtures were tested at various concentration levels between 1/160 and 1/2 (AMP/Bond). As a result, the optimum ratio was determined as 1/40. The antimicrobial efficacy of Nisin-added adhesive resin was tested against Streptococcus mutans (S. mutans) (ATCC 35,688) and Lactobacillus strains (cariogenic microorganisms). AMP formed a 2.7 cm diameter zone alone, while 1/40 AMP-bond mixture formed a 1.2 cm diameter zone. SBS values of the teeth bonded with Nisin added adhesive (17.49 ± 5.31) were significantly higher than the control group (14.54 ± 4.96) (P = 0.004). According to the four point scale, Nisin added adhesive provided a higher ARI score in favour of the adhesive and tooth compared to the control group (ARI = 3, n = 20). CONCLUSIONS: Nisin produced from L. lactis (ATCC 7962) had greater antimicrobial effects after mixing with adhesive bond against cariogenic microorganisms S. mutans (ATCC 35,688) and Lactobacillus strains. Nisin added adhesive increased shear bond strength (SBS) of orthodontic brackets and ARI scores in favor of adhesive & teeth. CLINICAL RELEVANCE: Clinicians should take into account that using Nisin-added adhesive resin in orthodontic treatments can provide prophylaxis against tooth decay, especially in patients with poor oral hygiene.


Assuntos
Colagem Dentária , Nisina , Braquetes Ortodônticos , Cimentos de Resina , Resistência ao Cisalhamento , Nisina/farmacologia , Humanos , Cimentos de Resina/farmacologia , Cimentos de Resina/química , Colagem Dentária/métodos , Lactococcus lactis , Análise do Estresse Dentário , Peptídeos Antimicrobianos/farmacologia , Peptídeos Antimicrobianos/química , Streptococcus mutans/efeitos dos fármacos , Dente Pré-Molar
2.
Stomatologiia (Mosk) ; 103(1): 5-7, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38372599

RESUMO

BACKGROUND: The era of using adhesives to fix brackets began in the 70s of the last century. There are eight generations of foreign-made adhesive systems for the restoration of teeth. However, until now, in orthodontics, the development of domestic adhesive systems with improved properties of adhesion of brackets to tooth enamel still important, especially in the posterior teeth. OBJECTIVE: The purpose of this work was to study the shear strength of fifth generation domestic adhesive between metal brackets and the enamel of molar teeth in laboratory conditions. MATERIAL AND METHODS: The study included 17 specimens of extracted maxillary molars embedded in acrylic resin blocks. Brackets from G&H Orthodontics (G&H Wire Company, USA) were fixed to the tooth enamel using the domestic Compofix (ortho) set. The enamel was treated with etching gel (37% phosphoric acid) for 30 seconds. Then the gel was washed off with water and the surface of the enamel was thoroughly dried. A primer was applied to the prepared surface with an applicator, inflated with a weak air flow for 5-10 seconds and photopolymerized for 20 seconds. The surface of the bracket was treated with degreaser, then a thin layer of adhesive was applied, and the sample was fixed to the enamel. Excess material was removed with an applicator. The samples were photopolymerized for 20 sec. Then, the shear bond strength of the adhesive was determined according to the method of GOST 31574-2012 on a (Zwick/Roell Z010 testing machine, Zwick, Germany). RESULTS: The shear strength of the adhesive joint obtained during the test is 13.54±1.01 MPa, the average value of the index of adhesive residues on the surface of the bracket was 23%±4%, which corresponds to the standard average values according to GOST. CONCLUSION: The tested domestic adhesive system of the fifth generation can be recommended for the practical work of an orthodontist.


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Humanos , Colagem Dentária/métodos , Cimentos Dentários , Esmalte Dentário , Dente Molar , Federação Russa , Teste de Materiais , Propriedades de Superfície , Análise do Estresse Dentário , Estresse Mecânico
3.
Biomater Investig Dent ; 11: 40585, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38873367

RESUMO

The purpose of this study was to evaluate the in vitro effect of orthodontic bracket base shape on shear bond strength (SBS) to human enamel and assess the nature of debonding fractures using the Adhesive Remnant Index (ARI). Orthodontic brackets with different-shaped bases (flower, heart, rectangle) were bonded to 120 extracted human third molars. Shear bond strength was measured using a Servohydraulic Test System at 24 h and 2 months after bonding. Adhesive Remnant Index scores were evaluated under 10x magnification to assess the amount of resin left on the tooth. The control bracket (rectangular base shape) had the highest mean SBS (26.8 ± 8.2 megapascals [MPa]), and significantly differed from the flower (17.2 ± 4.4 MPa) and heart (18.9 ± 3.5 MPa) base shapes (p < 0.001). The mean SBS between debonding times at 24 h (21.5 ± 7.4 MPa) and 2 months (20.4 ± 6.7 MPa) were not statistically significant (p > 0.05). Analysis of ARI scores showed a significant difference between flower-24 h versus heart-2 months (p = 0.039), flower-24 h versus heart-24 h (p = 0.004), and control-2 months versus heart-24 h (p = 0.015). Bracket base shape influenced SBS, with the rectangular base shape having a higher mean SBS compared to flower and heart base shapes. Variations in ARI scores occurred based on bracket shape and were of a mixed adhesive-cohesive nature. All bracket shapes had bond strengths above the clinically acceptable range of 6-8 MPa, and may thus provide adequate SBS in a clinical situation.

4.
Materials (Basel) ; 17(13)2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38998172

RESUMO

The results of orthodontic therapy largely depend, among other factors, on the preparation of the tooth enamel itself and the choice of material used to bond orthodontic brackets. The aim of this in vitro study was to determine the shear bond strength (SBS) and adhesive remnant index (ARI) score of thermo-cured glass-ionomers on different pretreated enamel, in comparison with the commonly used composite cement. Three commercially available nano-ionomer or highly viscous glass-ionomer cements (EQUIA Forte® Fil, EQUIA Fil, Ketac Universal) and two types of compo-sites (Heliosit Orthodontic, ConTec Go!) were investigated in this study. The research involved two hundred human premolars. The teeth were cleaned and polished, then randomly divided into five groups according to the enamel preparation method and the type of material. The enamel was treated in three different ways: polyacrylic acid, phosphoric acid, 5% NaOCl + etching with phosphoric acid, and a control group without treatment. Glass-ionomer cement was thermo-cured with heat from a polymerization unit during setting. Statistical analysis was performed using a Chi-square test and one-way ANOVA for independent samples. Spearman's Rho correlation coefficient was used to examine the relationship. Regardless of the material type, the results indicated that the weakest bond between the bracket and tooth enamel was found in samples without enamel pretreatment. The majority of the materials stayed on the brackets in samples without enamel preparation, according to ARI scores. The study's findings demonstrated that the strength of the adhesion between the bracket and enamel is greatly influenced by enamel etching and glass-ionomer thermo-curing. Clinical investigations would be required to validate the outcomes.

5.
Cureus ; 16(5): e60928, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38910749

RESUMO

INTRODUCTION: In orthodontics, shear bond strength plays an important role because it provides a good bond between the brackets and tooth surface; it avoids fracture of the tooth surface and prevents debonding of brackets from the tooth surface. All of these allow sufficient treatment time. Many factors, including the adhesive, its thickness, its strength, the bonding procedure, the clinician's ability, the base design, the geometry of the bracket, the material, and the kind of bracket all contribute to the shear bond strength. Brackets joined using conventional adhesive and adhesive pre-coated (APC) flash-free glue were the subjects of this comparison and evaluation research, which aimed to measure shear bond strength, enamel microfracture, and adhesive residual index. METHOD: 60 recently removed premolars from humans were used in this investigation. Before mounting on the acrylic block, the teeth were meticulously cleaned and preserved in artificial saliva. Two groups were formed from the collected premolars the control group and the experimental group. For the control group, we used American Orthodontics (AO) Master/Mini Master series brackets glued with resin composite kits. To make sure the adhesive was uniformly thick, we flashed extra adhesive around the brackets. In the meantime, samples were bonded using 3M Unitek APC flash-free technology in the experimental group. RESULTS: The research indicated that there was a statistically significant difference between the two groups to the adhesive remnant index (ARI) and mean shear bond strength. The shear bond strength of the experimental group averaged 10.96 megapascals (MPa), whereas the control group's was 5.70 MPa. The control group's ARI score was 2.97, whereas the experimental group's score was 2.4. There was no statistically significant change seen in enamel microfracture. CONCLUSION: A more robust shear bond may be possible using APC flash-free brackets. Compared to conventional bonding techniques and brackets, APC flash-free brackets have a lower adhesive residual index. The APC flash-free bracket technology also causes more enamel microfracture than conventional bonding and bracketing methods.

6.
F1000Res ; 12: 1442, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38264264

RESUMO

Background: The dental profession is seeing a constant influx of new adhesive systems from manufacturers, each claiming to be more dependable than the last. This study assessed the bond strength and adhesive remnants of different light-cured adhesives used for bonding metal brackets to teeth. Methods: 80 extracted maxillary premolars with the sound crown structure were acid etched and bonded with brackets on their buccal surfaces utilizing primer and light-cured adhesives into four equal groups, which are Transbond XT, Heliosit, Enlight, and Bracepaste. Shear bond strength (SBS) for de-bonding the brackets were evaluated with Instron- testing machine after 48 hours. The de-bonded samples' adhesive remnant index (ARI) scores were also measured. Results: The maximum mean SBS was found for Transbond XT (12.91 ± 2.0 MPa), followed by Bracepaste (12.87 ± 1.59 MPa), Enlight (11.77 ± 1.87 MPa), and lowest for Heliosit (10.93 ± 1.71 MPa). According to the four point scale, adhesive remnant index (ARI), Transbond XT has the least adhesive residue left on the tooth, followed by Heliosit. Enlight and Bracepaste have a similar distribution of adhesive, with both having a maximum amount left. Conclusion: It can be inferred that all groups involved demonstrated a satisfactory level of bond strength from a clinical perspective. Transbond XT is the preferred orthodontic adhesive over the other three adhesives due to its superior SBS and ARI properties.


Assuntos
Projetos de Pesquisa , Som
7.
Artigo em Chinês | WPRIM | ID: wpr-841842

RESUMO

Objective: To discuss the bond strengths of three kinds of metal bottom plate brackets commonly used in clinic and after sandblasting treatment under the condition of artificial saliva, and to evaluate their bonding properties. Methods: A total of 60 premolar teeth extracted because of orthodontic treatment were collected and divided into domestic Xinya bracket group (Xinya group), imported ultra thin MBT bracket group (MBT group), and Japan TOMY lock bracket group (TOMY group) (n= 20). The teeth were randomly divided into six groups after the three types of brackets fall off. The three types of new and sandblasting brackets were respectively bonded to the teeth randomly with 10 brackets in each group. The shear strength was detected by universal electronic mechanical testing machine, and the adhesive remnant index (ARI) of enamel surface in each group was obsereved, and the morphological features of three different base brackets and three shedding of brackets conducted by sandblasting were obsereved by scanning electron microscope. Results: Under the condition of artificial saliva, for the first bonding and bonding again, the shear strengths of the new brackets in TOMY goup were higher than those in Xinya group and MBT group (P0. 05). For the brackets treated with sandblasting after shedding in three groups, the shear strength in TOMY group was greater than those in Xinya group and MBT group (P0. 05). The shear strengths of brackets that were conducted by sandblasting after falling off in TOMY group and MBT group were increased compared with the original brackets (P0. 05). The scanning electron microscope results showed that three kinds of brackets were crisscroped with the mesh, and they were more dense in TOMY group. After sandblasting, the sand grains were embedded in the grid, and the sand grains were more embedded in the inverted pits in TOMY group and MBT group. After sandblasting again, the sand particle embedding scope was increased, and the grid structure of the network bottom in Xinya group was destroyed, but there were no obvious abnormities in MBT group and TOMY group. Conclusion: The bond strengths of the three types of bottom plate brackets can meet the clinical needs, and the bond strength in TOMY group is superior to those in Xinya group and MBT group. The use of sandblasting to deal with the shedding of TOMY and MBT brackets can improve the bond strengths of the brackets.

8.
Artigo em Coreano | WPRIM | ID: wpr-645456

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the clinical usefulness of 4 self etching primers by measuring the shear bond strength of orthodontic brackets and examining the failure pattern of bracket-tooth interfaces. METHODS: Seventy-five, defect-free, premolars were randomly assigned into five groups: control group (37% phosphoric acid + Transbond XT primer) and self etching primer treated groups (Transbond Plus self etching primer, Unifil bond, Clearfil SE bond, and Adhese). The shear bond strength was measured with a universal testing machine and the amount of residual adhesive remaining on the brackets after debonding was assessed by the adhesive remnant index (ARI). RESULTS: The results showed that the groups conditioned with self etching primer had significantly lower shear bond strength than the control group (p 0.05). Evaluation of the ARI scores indicated there was less resin remnant on the teeth in the groups conditioned with self etching primers, although not statistically significant. CONCLUSION: The results of this study suggest that all four of the self etching primers have shown acceptable bond strength for clinical use.


Assuntos
Adesivos , Dente Pré-Molar , Braquetes Ortodônticos , Dente
9.
Artigo em Coreano | WPRIM | ID: wpr-653477

RESUMO

The purpose of this study was to evaluate the effects of a self-etching primer on the shear bond strength of orthodontic brackets and on the failure pattern of bracket-adhesive interfaces in dry or wet condition. Brackets were bonded to extracted human teeth according to one of three experimental protocols. In the Group P, teeth were etched with 37% phosphoric acid. After the Transbond XT Primer was applied onto the etched surfaces, the brackets were bonded with Transbond XT(3M, Unitek, Monrovia, Calif) and light cured for 40 seconds. In the Group SD, a self-etching primer(3M, Unitek, Monrovia, Calif) was placed on the enamel for 3 seconds and gently evaporated with air, as suggested by the manufacturer. The brackets were then bonded with Transbond XT as in the Group P. In the Group SW, artificial saliva was applied to the enamel surface for 10 seconds to allow complete hydration of the surface before application self-etching primer. The brackets were then bonded following the procedures of Group SD. Each group was divided into 2 sub-groups(0.5h, 24h) according to debonding time. Shear bond strengths were measured by Instron universal testing machine. After debonding, the teeth and brackets were examined under scanning electron microscope and assessed with the adhesive remnant index. The result obtained were summarized as follows ; 1. The shear bond strengths were high enough to use clinically in all testing groups, but the shear bond strengths of Group SD and SW were significantly lower than Group P(p 0.05). 4. There was a greater frequency of ARI score of 0 and 1 with the Group P. On the other hand, there was a higher frequency of ARI scores of 2 and 3 with Group SD and Group SW(p < 0.05).


Assuntos
Humanos , Adesivos , Esmalte Dentário , Mãos , Braquetes Ortodônticos , Saliva Artificial , Dente
10.
Artigo em Coreano | WPRIM | ID: wpr-654127

RESUMO

A self-etching primer that combines the etchant and primer in one chemical compound saves time and should be more cost-effective to the clinician and patient. The purpose of this study was to evaluate the clinical effectiveness of a self-etching primer by measuring shear bond strengths according to various conditions and observing adhesive failure patterns. For this investigation, 120 upper and lower premolars extracted for orthodontic purposes were used and randomly divided into six groups of twenty teeth each. Human premolars were embedded in a metal cylinder with orthodontic resin. Metal brackets and ceramic brackets were bonded with XT primer and self-etching primer by means of XT adhesive. Upon curing, plasma arc light and visible light were used. After bonding, the shear bond strength was tested by Instron universal testing machine, and the amount of residual adhesive that remained on the tooth after debonding was measured by stereoscope and assessed with an adhesive remnant index. The results were as follows: 1. When brackets were bonded, if other conditions remained the same, there was no significant difference in shear bond strength due to the type of primer - either self-etching primer or XT primer. 2. When metal brackets were bonded, there was no significant difference in shear bond strength according to the source of light - plasma arc light or visible light - and type of primer. 3. There was a very significant difference in shear bond strength according to the type of brackets - metal or ceramic brackets. The shear bond strength of ceramic brackets was stronger than metal brackets. 4. When the adhesive failure patterns of metal brackets bonded with self-etching primer were observed by using the adhesive remnant index, the bond failure of the metal bracket occurred more frequently at the bracket-adhesive. The failure of the ceramic bracket, however, occurred more frequently at the enamel-adhesive interface. The adhesive failure patterns of metal brackets bonded with XT primer observed the same patterns. The above results suggest that self-etching primer can be clinically useful for bonding the brackets without fear of a decrease in shear bond strength.


Assuntos
Humanos , Adesivos , Dente Pré-Molar , Cerâmica , Luz , Plasma , Dente
11.
Artigo em Chinês | WPRIM | ID: wpr-670907

RESUMO

Objective: To investigate the adhesive characteristics of two kinds of light-curing resin that was used to bond teeth and orthodontics brackets. Methods: A total of 60 premolar teeth were randomly divided into six groups, and brackets were bonded according to the manufacturers' instructions. In group A1, A2 and A3, the teeth were prepared using 100 ml/L polyacrylic acid, and the brackets were bonded using Fuji Ortho LC. In group B1, B2 and B3, the teeth were using self-etching primer, and the brackets were bonded using Transbond Plus Self Etching Primer (TPSEP). After 30 min and 24 h under room temperature and received cold-heat cycle treatment respectively, bond strength was measured using a testing instrument (2000S, Lloyds Instruments, Fareham, England) at a speed of 1 mm/min, and the residual adhesive was quantified using a stereomicroscope. The adhesive interface was observed by scanning electron microscope. Results: The bond shear strength of TPSEP and Ortho Glass LC are more than 5 MPa. The bond shear strength of TPSEP is stronger than that of Ortho Glass LC after 24 h. However,The adhesive remnant index (ARI)of TPSEP is higher than that of Ortho Glass LC. Conclusion: Transbond Plus Self Etching Primer and Ortho Glass LC can satisfy the clinic need of orthodontics.

12.
Artigo em Coreano | WPRIM | ID: wpr-649909

RESUMO

The purpose of this study was to evaluate the clinical effectiveness of hydrophilic primer, which claim to retain adequate bond strength on moistened enamel resulting from moisture or saliva contamination, by comparing the shear bond strength and adhesive failure patterns of brackets bonded using hydrophilic primer and conventional hydrophobic primer. Brackets were bonded to human premolars embedded in metal cylinders utilizing light cured adhesive, primed with either a hydrophilic primer(Transbond MIP primer) or a conventional hydrophobic primer(Transbond XT primer). Each sample was exposed to varying degrees of artificial saliva contamination during the priming process. The shear bond strength was measured using a universal testing machine, and the adhesive failure patterns after debonding were visually examined by stereomicroscope and assessed using the adhesive remnant index(ARI). The results were as follows: 1. In dry conditions, no significant differences in shear bond strength between Transbond MIP and Transbond XT primers were found. 2. Transbond MIP primer exhibited a significantly higher shear bond strength than Transbond XT primer in saliva-contaminated conditions, regardless of the degree of contamination. 3. When contaminated with one coat of saliva, Transbond MIP primer did not exhibit significant differences in shear bond strength compared to the dry condition. When contaminated with two coats of saliva, Transbond MIP primer exhibited a significantly lower shear bond strength compared to the dry condition. 4. The adhesive remnant index of the adhesive failure pattern had a tendency to decrease, as the degree of saliva contamination increased. Bracket-adhesive interface failure was observed in more than half of the saliva contaminated samples utilizing Transbond MIP primer, whereas the bond failure sites of the Transbond XT primer samples occurred almost exclusively at the adhesive-enamel interface in saliva-contaminated conditions. The results of this study suggest that in cases where moisture control is difficult, Transbond MIP primer is an effective alternative to conventional hydrophobic primers.


Assuntos
Humanos , Adesivos , Dente Pré-Molar , Esmalte Dentário , Braquetes Ortodônticos , Saliva , Saliva Artificial
13.
Artigo em Coreano | WPRIM | ID: wpr-646412

RESUMO

The purpose of this study was to evaluate the clinical usefulness of plasma arc light which can reduce the curing time dramatically compared by shear bond strengths and failure patterns of the brackets bonded with visible light in direct bracket bonding. Some kinds of brackets were bonded with the Transbond(R) to the human premolars which were embedded in the resin blocks according to the various conditions. After bonding, the shear bond strength was tested by Instron universal testing machine and in addition , the amount of residual adhesive remaining on the tooth after debonding was measured by the stereoscope and assessed with adhesive remnant index(ARI). The results were as follows : 1. When plasma arc light was used for bonding the brackets, the shear bond strength was clinically sufficient in both metal and ceramic brackets, but resin brackets showed significantly lower bond strength but which was clinically useful. 2. When metal brackets were bonded using visible light, there was no significant difference in shear bond strength due to the light-curing time and the bond strength was clinically sufficient. 3. When the adhesive failure patterns of brackets bonded with plasma arc light were observed by using the adhesive remnant index, the bond failure of the metal and resin bracket occurred more frequently at bracket-adhesive interface but the failure of the ceramic bracket occurred more frequently at enamel-adhesive interface. 4. There was no statistically significant difference of the shear bond strength and adhesive failure pattern between metal bracket bonded for 2 seconds by curing with plasma arc light and 10 seconds by curing with visible light. 6. When metal brackets were bonded using plasma arc light, the shear bond strength decreased as the distance from the light source increased. The above results suggest that plasma arc light can be clinically useful for bonding the brackets without fear of the decrease of the shear bond strength.


Assuntos
Humanos , Adesivos , Dente Pré-Molar , Cerâmica , Luz , Plasma , Dente
14.
Artigo em Chinês | WPRIM | ID: wpr-670844

RESUMO

Objective:To evaluate the effects of different enamel conditioners in combination with an adhesive on the shear bond strength and the adhesive remnant index in vitro.Methods:One hundred and eight permanent healthy premolars from orthodontic patients and fresh saliva from a healthy young volunteer were collected.The teeth were cleaned,dried and etched by phosphoric acid,polyacrylic acid or Transbond plus SEP respectively(36 teeth for each agent).Then the teeth were bonded to brachet by RMGICs with the presence of water,saliva on the tooth surface or without any of them respectively(12 teeth in each group).After bonding,all samples were tested on a testing machine of Instron.Shear bond strength and adhesive remnant index were recorded.Results:Highest mean shear bond strength was observed in the group of teeth etched by Traspond plus SEP and bonded by RMGICs with the presence of saliva.Higher mean shear bond strength was obtained with the presence of saliva or water on the tooth surface than without any of them.Conclusion:Transbond plus SEP conditioning followed by RMGICs bonding may produce high shear bond strength between moistured tooth surface and brachet.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa