RESUMO
The anterior chamber of the eye (ACE) is distinct in its anatomy, optics, and immunology. This guarantees that the eye perceives visual information in the context of physiology even when encountering adverse incidents like inflammation. In addition, this endows the ACE with the special nursery bed iris enriched in vasculatures and nerves. The ACE constitutes a confined space enclosing an oxygen/nutrient-rich, immune-privileged, and less stressful milieu as well as an optically transparent medium. Therefore, aside from visual perception, the ACE unexpectedly serves as an excellent transplantation site for different body parts and a unique platform for noninvasive, longitudinal, and intravital microimaging of different grafts. On the basis of these merits, the ACE technology has evolved from the prototypical through the conventional to the advanced version. Studies using this technology as a versatile biomedical research platform have led to a diverse range of basic knowledge and in-depth understanding of a variety of cells, tissues, and organs as well as artificial biomaterials, pharmaceuticals, and abiotic substances. Remarkably, the technology turns in vivo dynamic imaging of the morphological characteristics, organotypic features, developmental fates, and specific functions of intracameral grafts into reality under physiological and pathological conditions. Here we review the anatomical, optical, and immunological bases as well as technical details of the ACE technology. Moreover, we discuss major achievements obtained and potential prospective avenues for this technology.
Assuntos
Câmara Anterior , Humanos , Estudos ProspectivosRESUMO
BACKGROUND: The purpose of this study is to assess the variations in anterior chamber depth (ACD), axial length (AXL), and intraocular pressure (IOP) in both phakic and pseudophakic eyes undergoing preoperative intravenous mannitol infusion. The study was conducted at the Ophthalmology Department of IRCSS Humanitas in Milan, Italy. This is a prospective and non-randomized study. METHODS: 40 patients with phakic eyes and 40 patients with pseudophakic eyes scheduled for cataract surgery in their fellow eye were included. Prior to the surgery, comprehensive ophthalmic examinations were conducted, including IOP measurement, and bilateral biometry performed with Anterion® (Heidelberg Engineering GmbH, 69,115, Heidelberg, Germany). All patients received intravenous infusion of mannitol before the surgery. One hour after cataract extraction, the patients underwent the same set of examinations. We analyzed the changes AXL, ACD and IOP in the eye opposite to the one that underwent surgery. RESULTS: The comparison between preoperative and postoperative parameters showed no differences in AXL (p = 0.34 and p = 0.53) and in ACD (p = 0.38 and p = 0.31) in the phakic and in the pseudophakic group, respectively. Instead, a statistically significant difference was found between the mean preoperative and postoperative IOP (p = 0.02) for the phakic group and (p = 0.03) for the pseudophakic group. CONCLUSIONS: The administration of mannitol does not lead to any changes in the ACD and AXL, regardless of whether the eyes are phakic or pseudophakic. However, there is a statistically significant reduction in IOP. Nonetheless, it is important to consider the various side effects associated with mannitol infusion.
RESUMO
BACKGROUND: The anatomic structure of the anterior chamber (AC) helps to explain differences in refractive status in school-aged children and is closely associated with primary angle closure (PAC). The aim of this study was to quantify and analyze the anterior chamber and angle (ACA) characteristics in Chinese children with different refractive status by swept-source optical coherence tomography (SS-OCT). METHODS: In a cross-sectional observational study, 383 children from two primary schools in Shandong Province, China, underwent a complete ophthalmic examination. First, the anterior chamber depth (ACD), anterior chamber width (ACW), angle-opening distance (AOD), and trabecular-iris space area (TISA) were evaluated automatically using a CASIA2 imaging device. AOD and TISA were measured at 500, 750 µm nasal (N1 and N2, respectively), and temporal (T1 and T2, respectively) to the scleral spur (SS). Cycloplegic refraction and axial length (AL) were then measured. According to spherical equivalent refraction (SER), the children were assigned to hyperopic (SER > 0.50D), emmetropic (-0.50D < SER ≤ 0.50D), and myopic groups (SER ≤ -0.50D). RESULTS: Out of the 383 children, 349 healthy children (160 girls) with a mean age of 8.23 ± 1.06 years (range: 6-11 years) were included. The mean SER and AL were - 0.10 ± 1.57D and 23.44 ± 0.95 mm, respectively. The mean ACD and ACW were 3.17 ± 0.24 mm and 11.69 ± 0.43 mm. The mean AOD were 0.72 ± 0.25, 0.63 ± 0.22 mm at N1, T1, and 0.98 ± 0.30, 0.84 ± 0.27 mm at N2, T2. The mean TISA were 0.24 ± 0.09, 0.22 ± 0.09mm2 at N1, T1, and 0.46 ± 0.16, 0.40 ± 0.14mm2 at N2, T2. The myopic group had the deepest AC and the widest angle. Compared with boys, girls had shorter AL, shallower ACD, narrower ACW, and ACA (all p < 0.05). By Pearson's correlation analysis, SER was negatively associated with ACD, AOD, and TISA. AL was positively associated with ACD, ACW, AOD, and TISA. In the multiple regression analysis, AOD and TISA were associated with deeper ACD, narrower ACW, and longer AL. CONCLUSION: In primary school students, the myopic eyes have deeper AC and wider angle. ACD, ACW, AOD, and TISA all increase with axial elongation. ACA is highly correlated with deeper ACD.
Assuntos
Câmara Anterior , Refração Ocular , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Criança , Feminino , Masculino , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , China/epidemiologia , Refração Ocular/fisiologia , Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/etnologia , Erros de Refração/fisiopatologia , População do Leste AsiáticoRESUMO
PURPOSE: To research the accuracy of intraocular lens (IOL) calculation formulas and investigate the effect of anterior chamber depth (ACD) and lens thickness (LT) measured by swept-source optical coherence tomography biometer (IOLMaster 700) in patients with posterior chamber phakic IOL (PC-pIOL). METHODS: Retrospective case series. The IOLMaster 700 biometer was used to measure axial length (AL) and anterior segment parameters. The traditional formulas (SRK/T, Holladay 1 and Haigis) with or without Wang-Koch (WK) AL adjustment, and new-generation formulas (Barret Universal II [BUII], Emmetropia Verifying Optical [EVO] v2.0, Kane, Pearl-DGS) were utilized in IOL power calculation. RESULTS: This study enrolled 24 eyes of 24 patients undergoing combined PC-pIOL removal and cataract surgery at Xiamen Eye Center of Xiamen University, Xiamen, Fujian, China. The median absolute prediction error in ascending order was EVO 2.0 (0.33), Kane (0.35), SRK/T-WKmodified (0.42), Holladay 1-WKmodified (0.44), Haigis-WKC1 (0.46), Pearl-DGS (0.47), BUII (0.58), Haigis (0.75), SRK/T (0.79), and Holladay 1 (1.32). The root-mean-square absolute error in ascending order was Haigis-WKC1 (0.591), Holladay 1-WKmodified (0.622), SRK/T-WKmodified (0.623), EVO (0.673), Kane (0.678), Pearl-DGS (0.753), BUII (0.863), Haigis (1.061), SRK/T (1.188), and Holladay 1 (1.513). A detailed analysis of ACD and LT measurement error revealed negligible impact on refractive outcomes in BUII and EVO 2.0 when these parameters were incorporated or omitted in the formula calculation. CONCLUSION: The Kane, EVO 2.0, and traditional formulas with WK AL adjustment displayed high prediction accuracy. Furthermore, the ACD and LT measurement error does not exert a significant influence on the accuracy of IOL power calculation formulas in highly myopic eyes implanted with PC-pIOL.
Assuntos
Biometria , Catarata , Lentes Intraoculares Fácicas , Refração Ocular , Tomografia de Coerência Óptica , Humanos , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Biometria/métodos , Refração Ocular/fisiologia , Catarata/complicações , Adulto , Óptica e Fotônica , Reprodutibilidade dos Testes , Idoso , Comprimento Axial do Olho/diagnóstico por imagem , Comprimento Axial do Olho/patologia , Câmara Anterior/diagnóstico por imagem , Acuidade Visual/fisiologia , Implante de Lente Intraocular/métodosRESUMO
BACKGROUND: An enhanced monofocal intraocular lenses (IOLs) (Tecnis Eyhance ICB00 and Tecnis Eyhance Toric DIU) has been developed to enhance intermediate vision while avoiding the disadvantages of multifocal IOLs. Although many studies have demonstrated the improvement of intermediate visual acuity with enhanced monofocal IOLs, it is not known specifically for which patients these IOLs should be recommended or avoided. In this study, we aim to find out which ocular parameters affect vision performance and photic phenomenon of ICB00 or DIU at different distances. METHODS: Patients who underwent cataract surgery with ICB00 or DIU, performed by a single surgeon, were included. Before surgery, the patients' age, gender, axial length, anterior chamber depth, spherical aberration Z (4,0), vertical coma, horizontal coma, angle kappa (κ), angle alpha (α), and other ocular parameters were investigated. One month after surgery, uncorrected near visual acuity (UNVA at 40 cm), uncorrected intermediate visual acuity (UIVA at 66 cm), uncorrected distance logMAR visual acuity (UDVA), IOL decentration, and quality of vision (QoV) questionnaires were conducted. RESULTS: A total of 43 patients (58 eyes) were included. The results of the univariate linear regression analyses showed a negative correlation between spherical aberration and logMAR UNVA and UIVA (p = 0.003, ß=-0.51 and p = 0.018, ß=-0.23, respectively) and a positive correlation between angle α and logMAR UIVA (p = 0.036, ß = 0.19). Deeper anterior chamber depth (ACD) was associated with poorer total QoV (p = 0.018, ß = 14.43), particularly in glare, halo, blur, and fluctuation perception. A higher degree of IOL decentration tended to decrease UNVA and UIVA (Pearson correlation coefficient, r = 0.336 and r = 0.221, respectively); however, no significant effect was observed on UDVA (Pearson correlation coefficient, r = 0.042). CONCLUSIONS: In enhanced monofocal IOLs, a higher level of spherical aberration is associated with better performance in UNVA and UIVA, whereas a larger angle α has a negative impact. A deeper ACD negatively affects the QoV.
Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Coma , Sensibilidades de Contraste , Visão Ocular , Desenho de Prótese , Satisfação do Paciente , Refração OcularRESUMO
BACKGROUND: To evaluate the difference in anterior chamber depth (ACD) between two eyes among keratoconus patients with binocular very asymmetric ectasia (VAE) and to explore the influencing factors. METHODS: The corneal curvature and ACD in both eyes of patients with VAE were measured by Sirius (version 3.2, CSO, Italy) at the following points: corneal vertex, maximum curvature (apex), and the 1.5 mm, 2.5 mm, and 3.5 mm superior-, inferior-, nasal-, temporal-paracentral from center. The mean pupil power (MPP) and corneal morphology parameters were also measured. Correlations between ACD and curvature and morphology parameters were analyzed by linear regression. RESULTS: 172 eyes of 86 patients (9 to 45 years) were classified into the VAE-N (n = 86) group and the VAE-E group (n = 86) based on the corneal morphology. The central (3.32 ± 0.27 mm versus 3.43 ± 0.29 mm, P < 0.001) and paracentral ACDs increased significantly in the VAE-E group, and the corneal morphology parameters were also significantly higher. The central ACD was significantly correlated with the MPP (r = 0.465), KVf/b (Keratoconus Vertex front/back) (r = 0.306, r = 0.327), and BCVf/b (Baiocchi Calossi Versaci front/back) (r = 0.356, r = 0.416). Linear regression showed good relationships between â³ACD and â³MPP (R2 = 0.429) and â³KVf/b (R2 = 0.504, R2 = 0.536). CONCLUSIONS: The ACD was larger in the VAE-E group. The difference in ACD between the VAE-E and VAE-N groups was significantly correlated with corneal curvature and the extent of corneal elevation, indicating the influences of both the corneal magnification effect and corneal ectasia on ACD.
Assuntos
Ceratocone , Humanos , Ceratocone/complicações , Ceratocone/diagnóstico , Topografia da Córnea , Paquimetria Corneana , Dilatação Patológica , Córnea , Câmara AnteriorRESUMO
BACKGROUND: To investigate the efficiency of a new method for the prevention of argentinian flag sign during the process of continuous, circular, and centered anterior capsulotomy (CCC) on the anterior capsule in cortically liquefied intumescent cataracts. This study was registered in an appropriate registry and the registration number of registration was xyy11[2022]-XJSFX-087; The date of of registration was 2022-04-29. METHODS: Preoperative examinations including slit-lamp examination, ocular A-scan ultrasonography, and Ultrasound Biomicroscopy (UBM) UBM were conducted on 61 patients with intumescent cataracts. Cases with cortically liquefied intumescent cataracts were selected and after staining with indocyanine green, the anterior chamber air bubble technique was used to compress the anterior capsule, and liquefied cortex was aspirated using a puncture needle. Corrected Distance Visual Acuity (CDVA) and intraocular pressure were recorded on postoperative days 1, 1 week, 1 month, and 6 months. Intraoperative and postoperative complications were documented and analyzed. RESULTS: Fifty eyes were identified as having cortically liquefied intumescent cataracts. No cases of the Argentinian flag sign occurred, and standard capsulorrhexis was achieved, facilitating smooth phacoemulsification. All patients achieved satisfactory outcomes at follow-ups of 1 day, 1 week, 1 month, and 6 months postoperatively. Mild corneal edema was observed in three cases on the first postoperative day, with no other complications noted. CONCLUSIONS: The anterior chamber air bubble technique combined with cortical fluid release technique can prevent the occurrence of the Argentinian flag sign in cortically liquefied intumescent cataracts, this method is simple, convenient and economic for the clinical promotion.
Assuntos
Câmara Anterior , Catarata , Facoemulsificação , Acuidade Visual , Humanos , Feminino , Masculino , Câmara Anterior/diagnóstico por imagem , Idoso , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Facoemulsificação/métodos , Microscopia Acústica , Ar , Capsulorrexe/métodos , Complicações Pós-Operatórias/prevenção & controle , Adulto , Idoso de 80 Anos ou mais , Cápsula do Cristalino/cirurgia , Cápsula do Cristalino/diagnóstico por imagemRESUMO
PURPOSE: To compare the biometric measurements obtained from the Pentacam AXL Wave, IOLMaster 700, and ANTERION and calculate the recommended intraocular lens power using the Barrett Formulae. METHODS: This was a retrospective cross-sectional study of patients who underwent biometry using the Pentacam AXL Wave, IOLMaster 700, and ANTERION. Flat keratometry (K1), steep keratometry (K2), anterior chamber depth (ACD), and axial length (AL) from each device were measured and compared. These parameters were used to calculate the recommended IOL powers using the Barrett formula. RESULTS: The study included 252 eyes of 153 patients. The IOLMaster had the highest acquisition rate among the two biometers. The Pentacam obtained the shortest mean AL, the IOLMaster measured the highest mean keratometry values, and the ANTERION measured the highest mean ACD. In terms of pairwise comparisons, keratometry and axial length were not significantly different between the Pentacam-IOLMaster and ANTERION-IOLMaster groups, while the rest of the pairwise comparisons were statistically significant. In nontoric and toric eyes, 35-45% of patients recommended the same sphere of IOL power. In another 30-40%, the Pentacam and ANTERION recommended an IOL power one step greater than that of the IOLMaster-derived data. 50% of the study population recommended the same toric-cylinder IOL power. CONCLUSIONS: The Pentacam AXL Wave, IOLMaster 700, and ANTERION can reliably provide data for IOL power calculations; however, these data are not interchangeable. In nontoric and toric eyes, 35-45% of cases recommended the same sphere IOL power, and in another 30-40%, the Pentacam and ANTERION recommended one-step higher IOL power than the IOLMaster-derived data. In targeting emmetropia, selecting the first plus IOL power is advisable when using the Pentacam and ANTERION to approximate the IOL power calculations recommended by the IOLMaster 700.
Assuntos
Biometria , Interferometria , Lentes Intraoculares , Tomografia de Coerência Óptica , Humanos , Estudos Retrospectivos , Estudos Transversais , Masculino , Biometria/instrumentação , Biometria/métodos , Feminino , Pessoa de Meia-Idade , Interferometria/instrumentação , Interferometria/métodos , Idoso , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/instrumentação , Comprimento Axial do Olho/diagnóstico por imagem , Adulto , Idoso de 80 Anos ou mais , Refração Ocular/fisiologia , Óptica e Fotônica , Câmara Anterior/diagnóstico por imagemRESUMO
BACKGROUND: Accurate prediction of postoperative vault in implantable collamer lens (ICL) implantation is crucial; however, current formulas often fail to account for individual anatomical variations, leading to suboptimal visual outcomes and necessitating improved predictive models. We aimed to verify the prediction accuracy of our new predictive model for vaulting based on anterior and posterior chamber structural parameters. METHODS: This retrospective observational study included 137 patients (240 eyes) who previously underwent ICL surgery. Patients were randomly divided into the model establishment (192 eyes) or validation (48 eyes) groups. Preoperative measurements of the anterior and posterior chamber structures were obtained using Pentacam, CASIA2 anterior segment optical coherence tomography (AS-OCT), ultrasound biomicroscopy, and other devices. Stepwise multiple linear regression analysis was used to evaluate the relationship between the vault and each variable (WL formula). The Friedman test was performed for the vaulting prediction results of the WL, NK (Ver. 3), and KS formulas (Ver. 4) in CASIA2 AS-OCT, as well as the Zhu formula and vault measurements. The proportions of prediction error within ± 250 µm per formula were compared. RESULTS: The predicted vault values of the WL, NK, KS, and Zhu formulas and vault measurements were 668.74 ± 162.12, 650.85 ± 248.47, 546.56 ± 128.99, 486.56 ± 210.76, and 716.06 ± 233.84 µm, respectively, with a significant difference (χ2 = 69.883, P = 0.000). Significant differences were also found between the measured vault value and Zhu formula, measured vault value and KS formula, WL formula and Zhu formula, WL formula and KS formula, NK formula and KS formula, and NK formula and Zhu formula (P < 0.001) but not between other groups. The proportions of prediction error within ± 250 µm per formula were as follows: WL formula (81.3%) > NK formula (70.8%) > KS formula (66.7%) > Zhu formula (54.2%). CONCLUSIONS: The WL formula, which considers the complexity of the anterior and posterior chamber structures, demonstrates greater calculation accuracy, compared with the KS (Ver. 4) and Zhu formulas. The proportion of absolute prediction error ≤ 250 µm is higher with the WL formula than with the NK formula (ver. 3). This enhanced predictive capability can improve ICL sizing decisions, thereby increasing the safety and efficacy of ICL implantation surgeries.
Assuntos
Implante de Lente Intraocular , Tomografia de Coerência Óptica , Humanos , Estudos Retrospectivos , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Adulto , Implante de Lente Intraocular/métodos , Câmara Anterior/diagnóstico por imagem , Lentes Intraoculares Fácicas , Miopia/cirurgia , Microscopia Acústica/métodos , Adulto Jovem , Pessoa de Meia-Idade , Acuidade Visual , Biometria/métodos , Refração Ocular/fisiologiaRESUMO
BACKGROUND: Chronic obstructive pulmonary disease (COPD) is a persistent, chronic inflammatory disease of the lungs. Tiotropium, used in the treatment of COPD, is a muscarinic receptor antagonist that provides long-acting bronchodilation. Our study aimed to investigate the effects of Tiotropium on anterior chamber parameters. METHODS: The study was conducted as an observational cross-sectional and prospectively between October 2023 and April 2024. Patients were examined in three groups: Group 1 consisted of untreated COPD patients; Group 2 consisted of healthy volunteers similar age and gender, and Group 3 included COPD patients receiving Tiotropium 18 mcg via HandiHaler. Anterior chamber parameters, intraocular pressure values, and photopic-mesopic pupil diameters were measured at the initial visit for Group 1 and Group 2 patients, and at the third month of treatment for Group 3 patients. RESULTS: Thirty-six patients were included in each group in the study. No significant differences were observed in ocular findings between the patient and control groups. In COPD patients receiving Tiotropium, narrowing of angle parameters, an increase in photopic-mesopic pupil diameters, and intraocular pressure were observed at the third month of treatment. CONCLUSION: This study is the first research that investigate the effects of Tiotropium on anterior chamber parameters, pupil diameters, and intraocular pressure in COPD treatment. In conclusion, patients with COPD receiving Tiotropium therapy for three months showed narrowing in angle parameters, an increase in intraocular pressure, and photopic-mesopic pupil diameter; however, no patients developed drug-induced acute angle closure glaucoma. TRIAL REGISTRATION: An independent ethics committee approved the study (Giresun EAH KEAK 2023/180 and 9.10.2023/02) which was performed in accordance with the Declaration of Helsinki, Guidelines for Good Clinical Practice. The study was conducted as prospectively, observational case-control. The Clinical Trial Number obtained for the study is NCT06525051 and was taken on 2024-07-29.
Assuntos
Broncodilatadores , Pressão Intraocular , Doença Pulmonar Obstrutiva Crônica , Brometo de Tiotrópio , Humanos , Brometo de Tiotrópio/uso terapêutico , Brometo de Tiotrópio/administração & dosagem , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Feminino , Masculino , Estudos Transversais , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Pressão Intraocular/efeitos dos fármacos , Broncodilatadores/uso terapêutico , Câmara Anterior/efeitos dos fármacos , Pupila/efeitos dos fármacosRESUMO
INTRODUCTION: This study aimed to determine the interchangeability of bilateral anterior chamber depth (ACD) in intraocular lens (IOL) power calculations for cataractous eyes and refractive outcomes using the unaffected fellow eye's ACD in subluxated crystalline lenses. METHODS: The predicted postoperative spherical equivalent (SE) calculated using the Kane formula with and without fellow eye's ACD in 202 cataract patients was compared. Refractive outcomes of the newer formulas (the Kane, Barrett Universal II [BUII], and Pearl-DGS formulas) with affected eye's ACD and with unaffected fellow eye's ACD were compared in 33 eyes with lens subluxation (the affected eye) undergoing in-the-bag IOL implantation. The SD of the prediction error (PE) was assessed using the heteroscedastic method. RESULTS: In 202 paired cataractous eyes, no marked ACD difference was found bilaterally; the predicted SE obtained without the fellow eye's ACD was comparable with that calculated with the fellow eye one (p = 0.90), with a mean absolute difference of 0.03 ± 0.03 D. With the affected eye AL, keratometry, and ACD, the median absolute error (MedAE) was 0.38-0.64 D, and the percentage of PE within ±0.50 D was 30.30-57.58%. The unaffected eye's ACD improved the results (MedAE, 0.35-0.49 D; the percentage of PE within ±0.50 D, 54.55-63.64%). The SDs of the BUII (0.82 D) and Pearl-DGS formulas (0.87 D) with the affected eye's ACD were significantly larger than those of the Kane and Pearl-DGS formulas (both 0.69 D) with the unaffected eye's ACD. CONCLUSION: Bilateral ACD was interchangeable in IOL power calculation for cataractous eyes when using the Kane formula. Unaffected eye's ACD in lieu of affected eye's ACD can enhance the accuracy of newer formulas in patients with unilateral subluxated lenses undergoing in-the-bag IOL implantation.
Assuntos
Câmara Anterior , Subluxação do Cristalino , Lentes Intraoculares , Refração Ocular , Humanos , Masculino , Feminino , Idoso , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Subluxação do Cristalino/cirurgia , Subluxação do Cristalino/diagnóstico , Subluxação do Cristalino/fisiopatologia , Adulto , Acuidade Visual , Estudos Retrospectivos , Óptica e Fotônica , Implante de Lente Intraocular/métodos , Biometria/métodos , Idoso de 80 Anos ou maisRESUMO
BACKGROUND: To establish a novel vault prediction formula after implantable collamer lens (ICL) implantation that considers both anterior and posterior chamber characteristics with multi-modal parameters. METHODS: A total of 103 and 65 eyes were included in the development and validation groups, respectively. Exploratory factor analysis was performed using data from optical coherence tomography and ultrasound biomicroscopy in the development group to synthesise summative factors with different clinical significance. Dominant original metrics with heavy loadings on significant factors (absolute value of the loading coefficient >0.5) were screened for multivariate linear regression models using a stepwise method. The newly derived formula was evaluated and compared to the NK and KS formulas in the validation group. RESULTS: Six factors (anterior chamber angle, horizontal width, lens, iris, iridociliary complex and ciliary body) were generated after dimension reduction via factor analysis. Factors 2 (horizontal width), 3 (lens), and 5 (iridociliary complex) had a significant influence on the vault. When dominant metrics on these factors were screened for further model building, ICL size, anterior chamber width, crystalline lens rise, iris curvature, and iris-ciliary process distance were retained in the final formula, with an adjusted R2 of 0.698, a median absolute error of 81.97 mm, and a root-mean-square error of 103.35 mm. CONCLUSIONS: Multiple intraocular components, including the lens, iris, and ciliary body, play important roles in vault determination. The new formula exhibits good accuracy for vault predictions and ICL size recommendations.
RESUMO
An approximately 1.5-year-old mixed breed heifer was presented for evaluation and treatment due to ocular pain affecting the right eye secondary to a live nematode within the anterior chamber. Ophthalmic examination revealed marked blepharospasm, evidence of chronic keratitis, uveitis, and a single, white, approximately 2.5 cm long, 0.5 mm thick, living parasite. The heifer underwent general anesthesia, and the parasite was removed using passive aqueous humor outflow following a stab incision into the anterior chamber. Twenty-four hours after removal of the intraocular parasite, the heifer displayed a significant improvement in ocular comfort, corneal edema, and uveitis. The nematode was identified via genetic analyses as Parafilaria bovicola, a filarial parasite of cattle. The heifer was discharged 5 days following nematode removal with a marked improvement in all ocular signs and apparently normal vision. To the authors' knowledge, there are no previous reports of confirmed intraocular filariosis caused by P. bovicola in the veterinary literature, nor are there reports detailing surgical removal of intraocular parasites in bovids.
RESUMO
OBJECTIVE: The objective of the study was to evaluate visual outcomes between medical treatment alone (MED) and Ahmed glaucoma valve implantation (AGVI) in Shiba dogs with primary angle closure glaucoma (PACG). PROCEDURES: Records of 65 Shiba dogs (104 eyes) with PACG were retrospectively reviewed. Vision was assessed qualitatively using both the menace response and maze testing. The significance of age, sex, intraocular pressure (IOP), and duration of clinical signs (≤72 h or >72 h) at first presentation (V1) was assessed. Eyes with vision at V1 were divided into groups according to subsequent treatment method (MED versus AGVI), and vision as a survival outcome was compared between group by the Kaplan-Meier method. RESULTS: At V1, 65 eyes (62.5%) of 54 dogs had vision. There was no statistically significant difference in age or sex on the presence of vision at V1. Median IOP was higher in blind (52 mmHg) compared to sighted eyes (28 mmHg) (p < .001). Eyes presenting in ≤72 h of the onset of clinical signs were more likely to have vision (86.7%) compared to those presenting after 72 h (44.1%) (p < .001). By the Kaplan-Meier analysis, the cumulative visual retention rate was significantly higher with AGVI than with MED (69.2% vs. 7.7%; p < .01) at 12 months. The median time to visual loss was 39.9 months with AGVI vs. 1.7 months with MED. CONCLUSIONS: AGVI resulted in better visual outcomes than MED and should be considered in Shiba dogs with PACG that are visual at the time of presentation and suitable for surgery.
RESUMO
The microbiome of the ocular surface has been characterised, but only limited information is available on a possible silent intraocular microbial colonisation in normal eyes. Therefore, we performed next-generation sequencing (NGS) of 16S rDNA genes in the aqueous humour. The aqueous humour was sampled from three patients during cataract surgery. Air swabs, conjunctival swabs from patients as well as from healthy donors served as controls. Following DNA extraction, the V3 and V4 hypervariable regions of the 16S rDNA gene were amplified and sequenced followed by denoising. The resulting Amplicon Sequence Variants were matched to a subset of the Ribosomal Database Project 16S database. The deduced bacterial community was then statistically analysed. The DNA content in all samples was low (0-1.49 ng/µL) but sufficient for analysis. The main phyla in the samples were Acinetobacteria (48%), Proteobacteria (26%), Firmicutes (14%), Acidobacteria (8%), and Bacteroidetes (2%). Patients' conjunctival control samples and anterior chamber fluid showed similar patterns of bacterial species containing many waterborne species. Non-disinfected samples showed a different bacterial spectrum than the air swab samples. The data confirm the existence of an ocular surface microbiome. Meanwhile, a distinct intraocular microbiome was not discernible from the background, suggesting the absence of an intraocular microbiome in normal eyes.
Assuntos
Humor Aquoso , Bactérias , Sequenciamento de Nucleotídeos em Larga Escala , Microbiota , RNA Ribossômico 16S , Humanos , Humor Aquoso/microbiologia , Microbiota/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , RNA Ribossômico 16S/genética , Bactérias/genética , Bactérias/classificação , Bactérias/isolamento & purificação , DNA Bacteriano/genética , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Análise de Sequência de DNA/métodosRESUMO
Proliferative diabetic retinopathy (PDR) is a vision-threatening complication of diabetes mellitus (DM). Anterior chamber (AC) flare and intraocular cytokines are potent biomarkers reflecting the intraocular immune status in PDR. This study aimed to elucidate the complex interrelationship between AC flare and intraocular cytokines in PDR eyes. A retrospective observational study was conducted on 19 PDR eyes of 19 patients with type 2 DM, and on 19 eyes of 19 patients with idiopathic macular hole or epiretinal membrane as controls. AC flare was measured before pars plana vitrectomy (PPV). Aqueous humor (AH) and vitreous fluid (VF) samples were collected at the time of PPV, and the quantities of 27 cytokines in both intraocular fluids were analyzed. In the PDR and control groups, Spearman's rank correlation analysis revealed a positive correlation between AC flare and IL-8 level in both AH and VF. Additionally, IL-8 levels in AH correlated positively with IL-8 levels in VF. In the PDR group, receiver operating characteristic curve analysis identified IL-8 level in AH as a significant predictor for both diabetic macular edema (DME) and vitreous hemorrhage (VH) complications. The cut-off values of IL-8 were established at ≥26.6 pg/mL for DME and ≥7.96 pg/mL for VH. Given the positive correlation between AC flare and AH IL-8 level, the present findings suggest that AC flare value may potentially be a non-invasive biomarker for predicting DME.
Assuntos
Câmara Anterior , Humor Aquoso , Retinopatia Diabética , Corpo Vítreo , Humanos , Retinopatia Diabética/imunologia , Retinopatia Diabética/metabolismo , Retinopatia Diabética/patologia , Retinopatia Diabética/etiologia , Masculino , Feminino , Câmara Anterior/patologia , Câmara Anterior/metabolismo , Câmara Anterior/imunologia , Pessoa de Meia-Idade , Idoso , Humor Aquoso/metabolismo , Humor Aquoso/imunologia , Estudos Retrospectivos , Corpo Vítreo/metabolismo , Corpo Vítreo/patologia , Edema Macular/etiologia , Edema Macular/metabolismo , Edema Macular/imunologia , Edema Macular/patologia , Vitrectomia , Biomarcadores , Citocinas/metabolismo , Interleucina-8/metabolismo , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/metabolismo , Diabetes Mellitus Tipo 2/imunologia , Curva ROCRESUMO
Trabeculectomy is the main surgical treatment for glaucoma, but scar formation during wound healing may lead to surgical failure. In this study, we evaluated the efficacy of anti-vascular endothelial growth factor (anti-VEGF) and mitomycin C (MMC) on wound healing after glaucoma surgery. We have been looking for Pubmed, Embase and other databases. The last time we looked at an electronic database was August 2023. A case control study was conducted to compare the use of anti-VEGF and mitomycin C for the treatment of glaucoma. We used the Cochrane standard methodology for collecting and analysing the data. Based on the criteria of inclusion, we have determined 369 related papers and selected seven eligible trials for data analysis. Three hundred and twenty-six cases were treated with trabeculectomy, of which 166 were injected with anti-VEGF and 160 were given MMC for trabeculectomy. In six trials, anti-VEGF and MMC were not found to have any statistical significance on postoperative wound leakage after surgery (OR, 1.55; 95% CI, 0.71, 3.35 p = 0.27). The three trials showed that anti-VEGF and MMC did not differ in terms of reducing postoperative wound hypotony after surgery (OR, 0.78; 95% CI, 0.20, 3.11 p = 0.73). Five trials demonstrated that anti-VEGF and MMC were not associated with a lower incidence of shallow anterior chamber (OR, 1.17; 95% CI, 0.5, 2.76 p = 0.71). There is no significant difference in the effect of anti-VEGF and MMC on wound healing after glaucoma surgery. A multicentre randomized controlled trial with a larger sample size is needed to confirm this study.
Assuntos
Glaucoma , Trabeculectomia , Humanos , Trabeculectomia/métodos , Mitomicina/uso terapêutico , Mitomicina/farmacologia , Fatores de Crescimento Endotelial , Estudos de Casos e Controles , Glaucoma/tratamento farmacológico , Glaucoma/cirurgia , Cicatrização , Resultado do TratamentoRESUMO
PURPOSE: To evaluate the effect of pregnancy on the anterior chamber, corneal parameter, and intraocular pressure measurements; and compare the results between trimesters, postpartum and non-pregnant healthy age-matched women. METHODS: This prospective study included 41 pregnant women and 53 non-pregnant women. Four measurements were taken from the pregnant women, in each trimester and postpartum third month, and once from the control group. Of the individuals included in the study, anterior chamber depth (ACD), anterior chamber volume (ACV), K1 (flat keratometry), K2 (steep keratometry), Kmean (mean value of K1 and K2), anterior chamber angle (ACA), central corneal thickness (CCT), thinnest corneal thickness (TCT), astigmatism value (AST), corneal volume (CV), biometry, axial length (AL), spherical equivalent (SFEQ), intraocular lens power (ILP), VA (visual acuity) datas were recorded. RESULTS: We observed a statistically significant decrease in K2, CCT, ACD, AL and CV in the postpartum period (p = 0.025, p < 0.001, p = 0.029, p = 0.005, p = 0.004 respectively) and a statistically significant increase in ACV, CCT, and TCT as the gestational week progressed in the pregnant group (p = 0.007, p < 0.001, p = 0.025, respectively). A statistically significant decrease in IOP towards to the third trimester, and an increase in the postpartum period was observed (p < 0.001). We did not observe statistically significant changes in K1, Kmean, AST, ACA, VA, ILP, and SFEQ values. CONCLUSION: It is important to investigate the physiological changes that may occur during pregnancy, distinguish them from pathological changes, and avoid unnecessary treatment. We consider that it's also important to guide the timing of anterior segment surgeries such as cataract and refractive surgery and to prescribe glasses/contact lenses.
Assuntos
Pressão Intraocular , Período Pós-Parto , Trimestres da Gravidez , Humanos , Feminino , Estudos Prospectivos , Gravidez , Adulto , Período Pós-Parto/fisiologia , Trimestres da Gravidez/fisiologia , Pressão Intraocular/fisiologia , Segmento Anterior do Olho/diagnóstico por imagem , Adulto Jovem , Acuidade Visual/fisiologia , Biometria/métodos , Córnea/diagnóstico por imagem , Córnea/anatomia & histologia , Câmara Anterior/diagnóstico por imagemRESUMO
PURPOSE: This study aims to investigate the influence of anterior chamber depth (ACD) and vault on the anterior chamber angle (ACA) morphology in myopic individuals implanted with posterior chamber phakic intraocular lenses. METHODS: This retrospective case series involved 231 eyes receiving a 13.2-mm implantable collamer lens (ICL). Preoperative anterior chamber anatomy was assessed using anterior segment optical coherence tomography (AS-OCT) and optical tomography, while postoperative evaluation employed AS-OCT. ACA morphology was characterized pre- and postoperatively through trabecular iris angle (TIA750), ACA distance opening (AOD750) and trabecular iris space area (TISA750). The influence of ACD and vault was examined by categorizing the sample into ACD (shallow, average and deep) and vault (low, optimal and high) groups. RESULTS: Preoperative ACA morphology varied based on ACD, with shallower ACDs exhibiting narrower TIA750, smaller AOD750 and TISA750. ICL implantation induced greater ACA narrowing more in the deep ACD group (TIA750 = 20.1 degrees; AOD750 = 0.82 mm and TISA750 = 0.44 mm2) compared to the shallow ACD group (TIA750 = 15.2 degrees; AOD750 = 0.44 mm and TISA750 = 0.21 mm2). Postoperatively, deeper ACDs showed larger ACAs. Increasing vault magnitude led to increased ACA narrowing, with the low vault group exhibiting smaller closure (TIA750 = 14.3 degrees; AOD750 = 0.56 mm and TISA750 = 0.29 mm2) compared to the high vault group (TIA750 = 20.8 degrees; AOD750 = 0.73 mm and TISA750 = 0.36 mm2). The magnitude of ACA narrowing associated with the vault had a consistent effect across different ACD groups. CONCLUSIONS: Posterior chamber intraocular lens implantation results in ACA narrowing, the extent of which is contingent upon preoperative anterior chamber and ACA morphology, with additional influence from vault magnitude.
Assuntos
Segmento Anterior do Olho , Glaucoma de Ângulo Fechado , Humanos , Implante de Lente Intraocular , Estudos Retrospectivos , Pressão Intraocular , Glaucoma de Ângulo Fechado/cirurgia , Câmara Anterior , Tomografia de Coerência Óptica/métodosRESUMO
PURPOSE: Subluxation of the crystalline lens (Ectopia Lentis, EL) can lead to significant visual impairment and serves as a diagnostic criterion for genetic disorders such as the Marfan syndrome. There is no established criterion to diagnose and quantify EL. We prospectively investigated the distance between the zonular fibre insertion and the limbus (ZLD) in healthy subjects as a parameter to assess the position of the lens, quantify EL and provide normative data. METHODS: This prospective, observational, cross-sectional study includes one-hundred-fifty eyes of 150 healthy participants (mean age 28 years, range 4-68). Pupils were dilated with tropicamide 0.5% and phenylephrine 2.5% eyedrops. ZLD was measured in mydriasis at the slit lamp as the distance between the most central visible insertions of the zonular fibres on the lens surface and the corneoscleral limbus. Vertical pupil diameter (PD) and refractive error were recorded. If zonular fibre insertions were not visible, the distance between limbus and the pupillary margin was recorded as ZLD. RESULTS: 145 right and 5 left eyes were examined. 93% of study subjects were Caucasian, 7% were Asian. In eyes with visible zonular fibre insertions (n = 76 eyes), ZLD was 1.30 ± 0.28 mm (mean ± SD, range 0.7-2.1) and PD was 8.79 ± 0.57 mm (7.5-9.8). In the remaining 74 eyes, ZLD was 1.38 ± 0.28 mm (0.7-2.1), and PD was 8.13 ± 0.58 mm (6.7-9.4). For all eyes, ZLD was 1.34 ± 0.29 mm (0.7-2.1), and PD was 8.47 ± 0.66 mm (6.7-9.8). Refractive error and sex did not significantly affect ZLD. Smaller PD and older age were associated with larger ZLD (P < 0.001 and P = 0.036, respectively). CONCLUSION: Average ZLD was 1.34 mm in eyes of healthy subjects. Older age correlated with larger ZLD. These normative data will aid in diagnosing and quantifying EL.