Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Nippon Med Sch ; 91(1): 88-98, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38462443

RESUMO

BACKGROUND: This study used finite element analysis (FEA) to investigate the effect of varus and valgus angle on the lateral compartment in unicompartmental knee arthroplasty (UKA). METHODS: One patient who underwent UKA was enrolled as the subject. Thirteen working conditions of the femoral prosthesis were simulated at varus and valgus angles of 0°, 2°, 4°, 6°, 8°, 10°, and 12°. A load of 1,000 N was applied downward along the mechanical axis of the femur, and the highest stress values on the surface of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage in each model were recorded. The six highest points were used to calculate the mean value. RESULTS: The highest stress values on the surface of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage increased with an increase in the femoral prosthesis varus/valgus angle. As compared with the standard position of the femoral prosthesis, there was no significant difference in the surface stress values of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus and tibial lateral plateau cartilage when the femoral prosthesis varus/valgus angle was less than 4° (p > 0.05). In addition, the stress magnitude on the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage significantly increased when the femoral prosthesis varus/valgus angle was greater than 4° (p < 0.001). CONCLUSIONS: The optimal femoral prosthesis varus/valgus angle in UKA was less than 4°.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Análise de Elementos Finitos , Fenômenos Biomecânicos , Fêmur/cirurgia , Polietileno
2.
Arch Bone Jt Surg ; 6(4): 301-311, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30175178

RESUMO

BACKGROUND: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedial osteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement over phase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rate and improved component alignment. We report the results of UKR with the new instrumentation in a consecutive series with a minimum follow-up of 2 years. METHODS: A prospective study of 115 cemented medial Oxford UKRs implanted in 89 patients was done. Post-operative alignment of the tibial and femoral components was analysed. Patient reported outcome measures were recorded using Oxford Knee Score (OKS) and the American Knee Society Score (KSS). Tegner Activity Scale (TAS) was used to record the activity level. RESULTS: 115 consecutive medial Oxford UKRs were studied. All patients were followed up annually in this prospective ethically approved study. The mean follow-up was 36 months and the minimum follow-up was 25 months. No patient died and none were lost to follow-up. At the final follow-up, the average OKS of the cohort was 39.5 (SD: 5.7). 91.2 % of the patients had good or excellent OKS with only 3.5 % reporting poor OKS. The overall limb alignment was 4.80 varus (0 - 140 varus). Tibia was recut in 5.2 % of cases. Median bearing size was 3 (range: 3 to 6). There was one case of bearing dislocation and one case of aseptic tibial loosening. CONCLUSION: This is the first study to report results of MP instrumentation at a minimum follow-up of 2 years. Our study indicates that the new instrumentation results in reliable and accurate implantation of femoral and tibial components in majority of the cases, with a decrease in number of alignment outliers, and also a reduced rate of bearing dislocation.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa