RESUMO
Galectins are a family of beta-galactoside-binding proteins that are characterised by their carbohydrate recognition domain (CRD) and include galectin-1 and galectin-3. These galectins have been implicated in numerous diseases due to their pleiotropic nature, including cancer and fibrosis, with therapeutic inhibitors being clinically developed to block the CRD. One of the early methods developed to characterise these galectins was the hemagglutination of red blood cells. Although it is insightful, this approach has been hampered by a lack of sensitivity and accurate quantification of the agglutination observed. In this study, we aimed to validate a more precise and quantitative method to enable the further investigation of differences between galectins in respect to agglutination induction in different blood groups, as well as the characterisation of small molecule inhibitors. Quantification of hemagglutination was shown to be optimal using U-bottom plates imaged and analysed with FIJI ImageJ rather than flat-bottom plates read for absorbance on an optical density plate reader. Galectin-3-induced red blood cell agglutination efficacy increased significantly from blood group O to A to B. However, for both the galectin-1 monomer and concatemer, a more comparable effect was observed between blood group B and O, but with more potent effects than in blood group A. Inhibition assays for both galectin-3 and galectin-1 induced-hemagglutination were able to demonstrate clear concentration responses and expected selectivity profiles for a set of small-molecule glycomimetics, confirming the historical profiles obtained in biochemical binding and functional cellular assays.
Assuntos
Eritrócitos , Galectina 1 , Galectinas , Hemaglutinação , Humanos , Eritrócitos/metabolismo , Eritrócitos/efeitos dos fármacos , Hemaglutinação/efeitos dos fármacos , Galectinas/antagonistas & inibidores , Galectinas/metabolismo , Galectina 1/antagonistas & inibidores , Galectina 1/metabolismo , Galectina 3/antagonistas & inibidores , Galectina 3/metabolismo , Testes de Aglutinação/métodos , Testes de Hemaglutinação , Aglutinação/efeitos dos fármacosRESUMO
The use of reconstituted human airway (RHuA) epithelial tissues to assess functional endpoints is highly relevant in respiratory toxicology, but standardised methods are lacking. In June 2015, the Institute for In Vitro Sciences (IIVS) held a technical workshop to evaluate the potential for standardisation of methods, including ciliary beat frequency (CBF). The applicability of a protocol suggested in the workshop was assessed in a multi-laboratory ring study. This report summarises the findings, and uses the similarities and differences identified between the laboratories to make recommendations for researchers in the absence of a validated method. Two software platforms for the assessment of CBF were used - Sisson-Ammons Video Analysis (SAVA; Ammons Engineering, Clio, MI, USA) and ciliaFA (National Institutes of Health, Bethesda, MD, USA). Both were utilised for multiple read temperatures, one objective strength (10×) and up to four video captures per tissue, to assess their utility. Two commercial RHuA tissue cultures were used: MucilAir™ (Epithelix, Geneva, Switzerland) and EpiAirway™ (MatTek, Ashland, MA, USA). IL-13 and procaterol were used to induce CBF-specific responses as positive controls. Further testing addressed the impact of tissue acclimation duration, the number of capture fields and objective strengths on baseline CBF readings. Both SAVA and ciliaFA reliably collected CBF data. However, ciliaFA failed to generate accurate CBF measurements above â¼10 Hz. The positive controls were effective, but were subject to inter-laboratory variability. CBF endpoints were generally uniform across replicate tissues, objective strengths and laboratories. Longer tissue acclimation increased the percentage active area, but had minimal impact on CBF. Taken together, these findings support the development and validation of a standardised CBF measurement protocol.
Assuntos
Cílios , Depuração Mucociliar , Epitélio , Humanos , Laboratórios , Software , Estados UnidosRESUMO
The detection of reactive oxygen species (ROS) using 2',7'-dichlorofluorescin diacetate (DCFDA) is commonly performed by a single measurement of fluorescence but this fails to capture a profile of ROS generation over time. This study aimed to develop a real-time monitoring method to increase the utility of the assay, to incorporate cytotoxicity screening and to describe the combined effects of DCFDA and the ROS generator, Ter-butyl hydrogen peroxide (TBHP). Breast cancer MCF-7 cells were loaded with DCFDA (0-50⯵M) for 45â¯min, and then exposed to TBHP (0-50⯵M). Fluorescence was recorded according to three different schedules: every hour for 6â¯h, or once after 6â¯h or 24â¯h. Viability was assessed in a crystal violet assay and cell morphology was examined by microscopy. TBHP caused a time and dose-dependent increase in ROS and the magnitude of the fluorescent signal was affected by the loading concentration of DCFDA. Reading the fluorescence every hour for 6â¯h did not diminish the emission signal. The most sensitive and reliable combination for this ROS assay was 10⯵M DCFDA with 25⯵M TBHP; since higher concentrations of DCFDA compromised cell viability. In conclusion we adapted a single point ROS assay to enable production of a profile of ROS generation over an extended 6â¯h period, and related this to cell viability and morphology.