Eur J Radiol ; 102: 9-14, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29685551

RESUMO

OBJECTIVES: The aim of this study was to investigate whether a flip angle adaptation, which is known to improve SNR and CNR in post contrast SSFP imaging, improves the precision and reproducibility of Feature Tracking (FT) derived strain assessments in post contrast bSSFP imaging. METHODS AND RESULTS: At 1.5T balanced SSFP midventricular short axis cine images were acquired with various flip angles (FA) before (FA = 50°) and 5 min after (FAs = 50°, 80°, 90°, 100°) injection of double dose Gadobutrol. FT derived systolic circumferential strain was then calculated for all pre- and post-contrast images, the intra- and inter-observer variability of strain measurements was assessed. FT derived midventricular peak systolic circumferential strain (PSCS) derived from unadapted (FA: 50°) contrast enhanced bSSFP images was significantly lower than strain derived from unenhanced bSSFP images (-16.45 ±â€¯5.1% vs -20.57 ±â€¯6.2%; p < 0.001) and showed low agreement (mean difference of -4.13 ±â€¯2.4, 95% CI:-5.3 to -3) in all 20 subjects. After adaption of the flip angle (FA: 100°), agreement between strain derived from unenhanced and adapted contrast enhanced bSSFP images (-20.57 ±â€¯6%) was strong (0.01 ±â€¯0.9, CI:-0.43 to 0.41). In comparison to intra- and interobserver variability of strain derived from unenhanced images (intra 2.9%; inter: 3.9%), strain measurements derived from adapted contrast enhanced images (FA: 100°) showed a slightly lower variability (intra: 2.5%; inter: 2.3%). CONCLUSION: If flip angle adaptation is performed, FT based strain analysis may be performed on contrast enhanced bSSFP cine images without loss of precision and accuracy.


Assuntos
Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Cardiomiopatias/patologia , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/normas , Imagem Cinética por Ressonância Magnética/normas , Masculino , Miocardite/patologia , Variações Dependentes do Observador , Compostos Organometálicos , Estudos Prospectivos , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia , Sístole , Função Ventricular Esquerda/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa