Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

País como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Reprod Domest Anim ; 59(1): e14525, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38268211

RESUMO

This research focused on evaluating blood mineral levels and malondialdehyde (MDA) as an indicator of oxidative stress before and after giving birth in Achai and Holstein Friesian (HF) dairy cows. Blood samples were obtained from a total of 50 cows representing both breeds on the third, second, and first week prior to calving, as well as on the day of calving (day 0). Subsequently, samples were collected on the 1-3 weeks postpartum to allow a comprehensive evaluation of blood parameters throughout the peripartum period. Results showed a significant (p < .01) decrease in serum zinc (Zn) levels on the day of parturition in both breeds. Additionally, HF cows exhibited higher (p < .01) Zn levels on week 2 before giving birth. Interestingly, blood selenium (Se) concentration increased (p < .01) in HF cows on weeks 2 and 3 after calving. In contrast, Achai cows showed a rise (p < .01) in blood Se on week 3 of parturition. Blood copper (Cu) levels were higher (p < .01) on weeks 2 and 3 after parturition in HF cows and on third week before parturition compared to Achai cows, where serum Cu remained high on week 1 of parturition. The findings indicated that blood magnesium (Mg) was higher (p < .01) on third week before parturition in Achai cows and on weeks 2 and 3 after parturition. Serum calcium (Ca) was higher (p < .01) in both HF and Achai cows on weeks 2 and 3 after parturition, and lower (p < .01) on third week before giving birth in both breeds. The mean blood MDA levels in Achai cows were lower (p < .01) on weeks 1 to 3 postpartum or 3 weeks before giving birth. In HF cows, serum MDA increased (p < .01) just before 2 weeks of parturition and remained elevated until 3 weeks of parturition. Thus, both breeds exhibited a similar pattern of mineral fluctuations; yet, Achai cows demonstrated greater resilience to oxidative stress compared to HF cows during the transition period.


Assuntos
Selênio , Gravidez , Feminino , Bovinos , Animais , Cobre , Parto Obstétrico/veterinária , Estresse Oxidativo , Período Pós-Parto
2.
BMC Public Health ; 23(1): 1518, 2023 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-37563609

RESUMO

BACKGROUND: Minerals have crucial biological functions in metabolism and are primarily obtained through diet. As a result, various dietary patterns can impact blood mineral levels. The aim of this study was to investigate the correlation between dietary patterns and the concentration of calcium, magnesium, iron, zinc, and copper in the bloodstream. METHODS: Three hundred eighty healthy children (53.7% male) were recruited in a region of Hunan Province in September 2019. We gathered basic information and measured physical proportions, along with completing a food frequency questionnaire (FFQ). Using principal component analysis (PCA), we determined dietary patterns. To analyze mineral levels in the blood, we used flame atomic absorption spectrometry (FAAS). We utilized linear regression models to investigate if certain dietary patterns are related to mineral concentration. RESULTS: Three dietary patterns were identified: 'Vegetables/Nuts,' 'Snacks/Beverages,' and 'Cereal/Beans.' Children from high-income families (annual average income > 50,000 yuan) prefer the 'Vegetables/Nuts' dietary pattern (P = 0.004). In comparison, those from low-income families (annual average income < 20,000 yuan) prefer the 'Snacks/Beverages' dietary pattern (P = 0.03). Following adjustment for age, gender, guardian's identity, education level, and annual household income. We found that an increase in the 'Vegetables/Nuts' pattern score (ß = 0.153, CI: 0.053 ~ 0.253; P = 0.003) and 'Snacks/Beverages' pattern score (ß = 0.103, CI: 0.002 ~ 0.204; P = 0.033) were significantly associated blood copper concentration. CONCLUSIONS: Household income was found to be associated with dietary behavior. Furthermore, higher blood copper concentration was significantly correlated with the 'Vegetables/Nuts' dietary pattern and 'Snacks/Beverages' dietary pattern, but the correlation is extremely low.


Assuntos
Cobre , Comportamento Alimentar , Humanos , Masculino , Criança , Feminino , Dieta , Verduras , China , Minerais
3.
Ann Dermatol ; 25(1): 67-72, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23467102

RESUMO

BACKGROUND: Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. OBJECTIVE: The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. METHODS: Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). RESULTS: All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. CONCLUSION: Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

4.
Annals of Dermatology ; : 67-72, 2013.
Artigo em Inglês | WPRIM | ID: wpr-66347

RESUMO

BACKGROUND: Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. OBJECTIVE: The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. METHODS: Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). RESULTS: All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. CONCLUSION: Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.


Assuntos
Cabelo , Testes Hematológicos , Minerais , Valores de Referência , Couro Cabeludo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa