1.
Magn Reson Med ; 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39385391

RESUMO

PURPOSE: To compare two blind source separation (BSS) techniques to principal component analysis and the electrocardiogram for the identification of cardiac triggers in self-gated free-running 5D whole-heart MRI. To ascertain the precision and robustness of the techniques, they were compared in three different noise and contrast regimes. METHODS: The repeated superior-inferior (SI) projections of a 3D radial trajectory were used to extract the physiological signals in three cardiac MRI cohorts: (1) 9 healthy volunteers without contrast agent injection at 1.5T, (2) 30 ferumoxytol-injected congenital heart disease patients at 1.5T, and (3) 12 gadobutrol-injected patients with suspected coronary artery disease at 3T. Self-gated cardiac triggers were extracted with the three algorithms (principal component analysis [PCA], second-order blind identification [SOBI], and independent component analysis [ICA]) and the difference with the electrocardiogram triggers was calculated. PCA and SOBI triggers were retained for image reconstruction. The image sharpness was ascertained on whole-heart 5D images obtained with PCA and SOBI and compared among the three cohorts. RESULTS: SOBI resulted in smaller trigger differences in Cohorts 1 and 3 compared to PCA (p < 0.01) and in all cohorts compared to ICA (p < 0.04). In Cohorts 1 and 3, the sharpness increased significantly in the reconstructed images when using SOBI instead of PCA (p < 0.03), but not in Cohort 2 (p = 0.4). CONCLUSION: We have shown that SOBI results in more precisely extracted self-gated triggers than PCA and ICA. The validation across three diverse cohorts demonstrates the robustness of the method against acquisition variability.

2.
J Magn Reson Imaging ; 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39143805

RESUMO

BACKGROUND: The rotating Cartesian k-space multiphase steady-state imaging with contrast (ROCK-MUSIC) pulse sequence enables acquisition of whole-heart, cardiac phase-resolved images in pediatric congenital heart disease (CHD) without reliance on the ventilator gating signal. Multidimensional reconstruction with low rank tensor (LRT) has shown promise for resolving complex cardiorespiratory motion. PURPOSE: To enhance ROCK-MUSIC by resolving cardiorespiratory phases using LRT reconstruction and to enable semi-automatic hyperparameter tuning by developing an image quality scoring model. STUDY TYPE: Retrospective. POPULATION: Thirty patients (45% female, age 2 days to 6.7 years) with CHD. FIELD STRENGTH/SEQUENCE: 3-T, four-dimensional (4D) spoiled gradient recalled echo sequence. ASSESSMENT: Eigenvector-based iTerative Self-consistent Parallel Imaging Reconstruction (ESPIRiT) served as the reference comparison for LRT reconstruction. A 4-point Likert scale was used for cardiac and vascular image quality scoring based on cardiac chamber definition, lumen signal uniformity, vascular margin clarity, and motion artifact. Ejection fraction and ventricular volumes were assessed in 16 patients. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge sharpness were computed. STATISTICAL TESTS: Intraclass correlation coefficients, Wilcoxon signed-rank test, Bland-Altman. A P-value <0.05 was considered statistically significant. RESULTS: Relative to ESPIRiT, LRT images received significantly higher cardiac (2.81 ± 0.57 vs. 3.19 ± 0.54) and vascular (2.81 ± 0.60 vs. 3.36 ± 0.53) image quality scores. Image quality scoring with semi-automated hyperparameter tuning showed strong correlations (R2 = 0.748) among image quality, SNR, and septal sharpness. Comparison of ejection fraction and volumetry derived from ESPIRiT, and LRT showed no significant systematic difference (P = 0.32). DATA CONCLUSION: Integration of low-rank reconstruction with ROCK-MUSIC acquisition may be feasible, and semi-automatic hyperparameter tuning could be effective for generating cardiorespiratory resolved images. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

3.
J Magn Reson Imaging ; 57(5): 1320-1339, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36484213

RESUMO

BACKGROUND: Particle tracing based on 4D Flow MRI has been applied as a quantitative and qualitative postprocessing technique to study temporally evolving blood flow patterns. PURPOSE: To systematically review the various methods to perform 4D Flow MRI-based particle tracing, as well as the clinical value, clinical applications, and current developments of the technique. STUDY TYPE: The study type is systematic review. SUBJECTS: Patients with cardiovascular disease (such as Marfan, Fontan, Tetralogy of Fallot), healthy controls, and cardiovascular phantoms that received 4D Flow MRI with particle tracing. FIELD STRENGTH/SEQUENCE: Three-dimensional three-directional cine phase-contrast MRI, at 1.5 T and 3 T. ASSESSMENT: Two systematic searches were performed on the PubMed database using Boolean operators and the relevant key terms covering 4D Flow MRI and particle tracing. One systematic search was focused on particle tracing methods, whereas the other on applications. Additional articles from other sources were sought out and included after a similar inspection. Particle tracing methods, clinical applications, clinical value, and current developments were extracted. STATISTICAL TESTS: The main results of the included studies are summarized, without additional statistical analysis. RESULTS: Of 127 unique articles retrieved from the initial search, 56 were included (28 for methods and 54 for applications). Most articles that described particle tracing methods used an adaptive timestep, a fourth order Runge-Kutta integration method, and linear interpolation in the time dimension. Particle tracing was applied in heart chambers, aorta, venae cavae, Fontan circulation, pulmonary arteries, abdominal vasculature, peripheral arteries, carotid arteries, and cerebral vasculature. Applications were grouped as intravascular, intracardiac, flow stasis, and research. DATA CONCLUSIONS: Particle tracing based on 4D Flow MRI gives unique insight into blood flow in several cardiovascular diseases, but the quality depends heavily on the MRI data quality. Further studies are required to evaluate the clinical value of the technique for different cardiovascular diseases. EVIDENCE LEVEL: 5. TECHNICAL EFFICACY: Stage 1.


Assuntos
Doenças Cardiovasculares , Humanos , Imageamento Tridimensional/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
4.
J Magn Reson Imaging ; 57(1): 191-203, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35506525

RESUMO

BACKGROUND: Segmenting the whole heart over the cardiac cycle in 4D flow MRI is a challenging and time-consuming process, as there is considerable motion and limited contrast between blood and tissue. PURPOSE: To develop and evaluate a deep learning-based segmentation method to automatically segment the cardiac chambers and great thoracic vessels from 4D flow MRI. STUDY TYPE: Retrospective. SUBJECTS: A total of 205 subjects, including 40 healthy volunteers and 165 patients with a variety of cardiac disorders were included. Data were randomly divided into training (n = 144), validation (n = 20), and testing (n = 41) sets. FIELD STRENGTH/SEQUENCE: A 3 T/time-resolved velocity encoded 3D gradient echo sequence (4D flow MRI). ASSESSMENT: A 3D neural network based on the U-net architecture was trained to segment the four cardiac chambers, aorta, and pulmonary artery. The segmentations generated were compared to manually corrected atlas-based segmentations. End-diastolic (ED) and end-systolic (ES) volumes of the four cardiac chambers were calculated for both segmentations. STATISTICAL TESTS: Dice score, Hausdorff distance, average surface distance, sensitivity, precision, and miss rate were used to measure segmentation accuracy. Bland-Altman analysis was used to evaluate agreement between volumetric parameters. RESULTS: The following evaluation metrics were computed: mean Dice score (0.908 ± 0.023) (mean ± SD), Hausdorff distance (1.253 ± 0.293 mm), average surface distance (0.466 ± 0.136 mm), sensitivity (0.907 ± 0.032), precision (0.913 ± 0.028), and miss rate (0.093 ± 0.032). Bland-Altman analyses showed good agreement between volumetric parameters for all chambers. Limits of agreement as percentage of mean chamber volume (LoA%), left ventricular: 9.3%, 13.5%, left atrial: 12.4%, 16.9%, right ventricular: 9.9%, 15.6%, and right atrial: 18.7%, 14.4%; for ED and ES, respectively. DATA CONCLUSION: The addition of this technique to the 4D flow MRI assessment pipeline could expedite and improve the utility of this type of acquisition in the clinical setting. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 1.


Assuntos
Fibrilação Atrial , Aprendizado Profundo , Humanos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Coração/diagnóstico por imagem
5.
MAGMA ; 36(2): 257-277, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36920549

RESUMO

OBJECTIVE: To examine the feasibility of human cardiac MR (CMR) at 14.0 T using high-density radiofrequency (RF) dipole transceiver arrays in conjunction with static and dynamic parallel transmission (pTx). MATERIALS AND METHODS: RF arrays comprised of self-grounded bow-tie (SGBT) antennas, bow-tie (BT) antennas, or fractionated dipole (FD) antennas were used in this simulation study. Static and dynamic pTx were applied to enhance transmission field (B1+) uniformity and efficiency in the heart of the human voxel model. B1+ distribution and maximum specific absorption rate averaged over 10 g tissue (SAR10g) were examined at 7.0 T and 14.0 T. RESULTS: At 14.0 T static pTx revealed a minimum B1+ROI efficiency of 0.91 µT/√kW (SGBT), 0.73 µT/√kW (BT), and 0.56 µT/√kW (FD) and maximum SAR10g of 4.24 W/kg, 1.45 W/kg, and 2.04 W/kg. Dynamic pTx with 8 kT points indicate a balance between B1+ROI homogeneity (coefficient of variation < 14%) and efficiency (minimum B1+ROI > 1.11 µT/√kW) at 14.0 T with a maximum SAR10g < 5.25 W/kg. DISCUSSION: MRI of the human heart at 14.0 T is feasible from an electrodynamic and theoretical standpoint, provided that multi-channel high-density antennas are arranged accordingly. These findings provide a technical foundation for further explorations into CMR at 14.0 T.


Assuntos
Coração , Imageamento por Ressonância Magnética , Humanos , Coração/diagnóstico por imagem , Simulação por Computador , Ondas de Rádio , Imagens de Fantasmas , Desenho de Equipamento
6.
Magn Reson Med ; 88(6): 2709-2717, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35916368

RESUMO

PURPOSE: Flow quantification by phase-contrast MRI is hampered by spatially varying background phase offsets. Correction performance by polynomial regression on stationary tissue may be affected by outliers such as wrap-around or constant flow. Therefore, we propose an alternative, M-estimate SAmple Consensus (MSAC) to reject outliers, and improve and fully automate background phase correction. METHODS: The MSAC technique fits polynomials to randomly drawn small samples from the image. Over several trials, it aims to find the best consensus set of valid pixels by rejecting outliers to the fit and minimizing the residuals of the remaining pixels. The robustness of MSAC to its few parameters was investigated and verified using third-order polynomial correction fits on a total of 118 2D flow (97 with wrap-around) and 18 4D flow data sets (14 with wrap-around), acquired at 1.5 T and 3 T. Background phase was compared with standard stationary correction and phantom correction. Pulmonary/systemic flow ratios in 2D flow were derived, and exemplary 4D flow analysis was performed. RESULTS: The MSAC technique is robust over a range of parameter choices, and a unique set of parameters is suitable for both 2D and 4D flow. In 2D flow, phase errors were significantly reduced by MSAC compared with stationary correction (p = 0.005), and stationary correction shows larger errors in pulmonary/systemic flow ratios compared with MSAC. In 4D flow, MSAC shows similar performance as stationary correction. CONCLUSIONS: The MSAC method provides fully automated background phase correction to 2D and 4D flow data and shows improved robustness over stationary correction, especially with outliers present.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Velocidade do Fluxo Sanguíneo , Consenso , Voluntários Saudáveis , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
7.
Magn Reson Med ; 88(4): 1720-1733, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35691942

RESUMO

PURPOSE: To develop and evaluate a free breathing non-electrocardiograph (ECG) myocardial T1 * mapping sequence using radial imaging to quantify the changes in myocardial T1 * between rest and exercise (T1 *reactivity ) in exercise cardiac MRI (Ex-CMR). METHODS: A free-running T1 * sequence was developed using a saturation pulse followed by three Look-Locker inversion-recovery experiments. Each Look-Locker continuously acquired data as radial trajectory using a low flip-angle spoiled gradient-echo readout. Self-navigation was performed with a temporal resolution of ∼100 ms for retrospectively extracting respiratory motion. The mid-diastole phase for every cardiac cycle was retrospectively detected on the recorded electrocardiogram signal using an empirical model. Multiple measurements were performed to obtain mean value to reduce effects from the free-breathing acquisition. Finally, data acquired at both mid-diastole and end-expiration are picked and reconstructed by a low-rank plus sparsity constraint algorithm. The performance of this sequence was evaluated by simulations, phantoms, and in vivo studies at rest and after physiological exercise. RESULTS: Numerical simulation demonstrated that changes in T1 * are related to the changes in T1 ; however, other factors such as breathing motion could influence T1 * measurements. Phantom T1 * values measured using free-running T1 * mapping sequence had good correlation with spin-echo T1 values and was insensitive to heart rate. In the Ex-CMR study, the measured T1 * reactivity was 10% immediately after exercise and declined over time. CONCLUSION: The free-running T1 * mapping sequence allows free-breathing non-ECG quantification of changes in myocardial T1 * with physiological exercise. Although, absolute myocardial T1 * value is sensitive to various confounders such as B1 and B0 inhomogeneity, quantification of its change may be useful in revealing myocardial tissue properties with exercise.


Assuntos
Imageamento por Ressonância Magnética , Miocárdio , Eletrocardiografia , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
Diabet Med ; 39(8): e14884, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35587779

RESUMO

AIMS: To investigate the relationship between fibro-inflammatory biomarkers and cardiovascular structure/function in people with Type 2 Diabetes (T2D) compared to healthy controls and the effect of two lifestyle interventions in T2D. METHODS: Data were derived from the DIASTOLIC randomised controlled trial (RCT) and includes a comparison between those with T2D and the matched healthy volunteers recruited at baseline. Adults with T2D without cardiovascular disease (CVD) were randomized to a 12-week intervention either: (1) exercise training, (2) a low-energy (∼810 kcal/day) meal-replacement plan (MRP) or (3) standard care. Principal Component and Fisher's linear discriminant analysis were used to investigate the relationships between MRI acquired cardiovascular outcomes and fibro-inflammatory biomarkers in cases versus controls and pre- and post-intervention in T2D. RESULTS: At baseline, 83 people with T2D (mean age 50.5 ± 6.4; 58% male) and 36 healthy controls (mean age 48.6 ± 6.2; 53% male) were compared and 76 people with T2D completed the RCT for pre- post-analysis. Compared to healthy controls, subjects with T2D had adverse cardiovascular remodelling and a fibro-inflammatory profile (20 differentially expressed biomarkers). The 3D data visualisations showed almost complete separation between healthy controls and those with T2D, and a marked shift towards healthy controls following the MRP (15 biomarkers significantly changed) but not exercise training. CONCLUSIONS: Fibro-inflammatory pathways and cardiovascular structure/function are adversely altered before the onset of symptomatic CVD in middle-aged adults with T2D. The MRP improved the fibro-inflammatory profile of people with T2D towards a more healthy status. Long-term studies are required to assess whether these changes lead to continued reverse cardiac remodelling and prevent CVD.


Assuntos
Doenças Cardiovasculares , Diabetes Mellitus Tipo 2 , Adulto , Biomarcadores , Restrição Calórica , Doenças Cardiovasculares/complicações , Diabetes Mellitus Tipo 2/complicações , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Magn Reson Med ; 86(5): 2862-2879, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34169546

RESUMO

PURPOSE: Design, implementation, evaluation, and application of a 32-channel Self-Grounded Bow-Tie (SGBT) transceiver array for cardiac MR (CMR) at 7.0T. METHODS: The array consists of 32 compact SGBT building blocks. Transmission field ( B1+ ) shimming and radiofrequency safety assessment were performed with numerical simulations and benchmarked against phantom experiments. In vivo B1+ efficiency mapping was conducted with actual flip angle imaging. The array's applicability for accelerated high spatial resolution 2D FLASH CINE imaging of the heart was examined in a volunteer study (n = 7). RESULTS: B1+ shimming provided a uniform field distribution suitable for female and male subjects. Phantom studies demonstrated an excellent agreement between simulated and measured B1+ efficiency maps (7% mean difference). The SGBT array afforded a spatial resolution of (0.8 × 0.8 × 2.5) mm3 for 2D CINE FLASH which is by a factor of 12 superior to standardized cardiovascular MR (CMR) protocols. The density of the SGBT array supports 1D acceleration of up to R = 4 (mean signal-to-noise ratio (whole heart) ≥ 16.7, mean contrast-to-noise ratio ≥ 13.5) without impairing image quality significantly. CONCLUSION: The compact SGBT building block facilitates a modular high-density array that supports accelerated and high spatial resolution CMR at 7.0T. The array provides a technological basis for future clinical assessment of parallel transmission techniques.


Assuntos
Coração , Ondas de Rádio , Desenho de Equipamento , Feminino , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Imagens de Fantasmas , Razão Sinal-Ruído
10.
Magn Reson Med ; 85(2): 855-867, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32851676

RESUMO

PURPOSE: Respiratory motion in cardiovascular MRI presents a challenging problem with many potential solutions. Current approaches require breath-holds, apply retrospective image registration, or significantly increase scan time by respiratory gating. Myocardial T1 and T2 mapping techniques are particularly sensitive to motion as they require multiple source images to be accurately aligned prior to the estimation of tissue relaxation. We propose a patient-specific prospective motion correction (PROCO) strategy that corrects respiratory motion on the fly with the goal of reducing the spatial variation of myocardial parametric mapping techniques. METHODS: A rapid, patient-specific training scan was performed to characterize respiration-induced motion of the heart relative to a diaphragmatic navigator, and a parametric mapping pulse sequence utilized the resulting motion model to prospectively update the scan plane in real-time. Midventricular short-axis T1 and T2 maps were acquired under breath-hold or free-breathing conditions with and without PROCO in 7 healthy volunteers and 3 patients. T1 and T2 were measured in 6 segments and compared to reference standard breath-hold measurements using Bland-Altman analysis. RESULTS: PROCO significantly reduced the spatial variation of parametric maps acquired during free-breathing, producing limits of agreement of -47.16 to 30.98 ms (T1 ) and -1.35 to 4.02 ms (T2 ), compared to -67.77 to 74.34 ms (T1 ) and -2.21 to 5.62 ms (T2 ) for free-breathing acquisition without PROCO. CONCLUSION: Patient-specific respiratory PROCO method significantly reduced the spatial variation of myocardial T1 and T2 mapping, while allowing for 100% efficient free-breathing acquisitions.


Assuntos
Interpretação de Imagem Assistida por Computador , Miocárdio , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos
11.
J Magn Reson Imaging ; 54(3): 777-786, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33629795

RESUMO

BACKGROUND: Although contrast agents would be beneficial, they are seldom used in four-dimensional (4D) flow magnetic resonance imaging (MRI) due to potential side effects and contraindications. PURPOSE: To develop and evaluate a deep learning architecture to generate high blood-tissue contrast in noncontrast 4D flow MRI by emulating the use of an external contrast agent. STUDY TYPE: Retrospective. SUBJECTS: Of 222 data sets, 141 were used for neural network (NN) training (69 with and 72 without contrast agent). Evaluation was performed on the remaining 81 noncontrast data sets. FIELD STRENGTH/SEQUENCES: Gradient echo or echo-planar 4D flow MRI at 1.5 T and 3 T. ASSESSMENT: A cyclic generative adversarial NN was trained to perform image translation between noncontrast and contrast data. Evaluation was performed quantitatively using contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), structural similarity index (SSIM), mean squared error (MSE) of edges, and Dice coefficient of segmentations. Three observers performed a qualitative assessment of blood-tissue contrast, noise, presence of artifacts, and image structure visualization. STATISTICAL TESTS: The Wilcoxon rank-sum test evaluated statistical significance. Kendall's concordance coefficient assessed interobserver agreement. RESULTS: Contrast in the regions of interest (ROIs) in the NN enhanced images increased by 88%, CNR increased by 63%, and SNR improved by 48% (all P < 0.001). The SSIM was 0.82 ± 0.01, and the MSE of edges was 0.09 ± 0.01 (range [0,1]). Segmentations based on the generated images resulted in a Dice similarity increase of 15.25%. The observers managed to differentiate between contrast MR images and our results; however, they preferred the NN enhanced images in 76.7% of cases. This percentage increased to 93.3% for phase-contrast MR angiograms created from the NN enhanced data. Visual grading scores were blood-tissue contrast = 4.30 ± 0.74, noise = 3.12 ± 0.98, and presence of artifacts = 3.63 ± 0.76. Image structures within and without the ROIs resulted in scores of 3.42 ± 0.59 and 3.07 ± 0.71, respectively (P < 0.001). DATA CONCLUSION: The proposed approach improves blood-tissue contrast in MR images and could be used to improve data quality, visualization, and postprocessing of cardiovascular 4D flow data. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 1.


Assuntos
Meios de Contraste , Aprendizado Profundo , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Razão Sinal-Ruído
12.
Curr Heart Fail Rep ; 18(4): 225-239, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33931818

RESUMO

PURPOSE OF REVIEW: Cardiac magnetic resonance-feature-tracking (CMR-FT)-based deformation analyses are key tools of cardiovascular imaging and applications in heart failure (HF) diagnostics are expanding. In this review, we outline the current range of application with diagnostic and prognostic implications and provide perspectives on future trends of this technique. RECENT FINDINGS: By applying CMR-FT in different cardiovascular diseases, increasing evidence proves CMR-FT-derived parameters as powerful diagnostic and prognostic imaging biomarkers within the HF continuum partly outperforming traditional clinical values like left ventricular ejection fraction. Importantly, HF diagnostics and deformation analyses by CMR-FT are feasible far beyond sole left ventricular performance evaluation underlining the holistic nature and accuracy of this imaging approach. As an established and continuously evolving technique with strong prognostic implications, CMR-FT deformation analyses enable comprehensive cardiac performance quantification of all cardiac chambers.


Assuntos
Insuficiência Cardíaca , Ventrículos do Coração , Insuficiência Cardíaca/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Volume Sistólico , Função Ventricular Esquerda
13.
Heart Fail Clin ; 17(1): 121-133, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33220881

RESUMO

"Cardiac imaging is an essential tool in the field of cardio-oncology. Cardiovascular magnetic resonance (CMR) stands out for its accuracy, reproducibility, and ability to provide tissue characterization. These attributes are particularly helpful in screening and diagnosing cardiotoxicity, infiltrative disease, and inflammatory cardiac disease. The ability of CMR to detect subtle changes in cardiac function and tissue composition has made it a useful tool for understanding the pathophysiology of cardiotoxicity. Because of these unique features, CMR is gaining prominence in both the clinical and research aspects of cardio-oncology."


Assuntos
Cardiologia , Neoplasias Cardíacas/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Oncologia , Humanos
14.
NMR Biomed ; 33(11): e4394, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32815236

RESUMO

Preclinical 4D flow MRI remains challenging and is restricted for parallel imaging acceleration due to the limited number of available receive channels. A radial acquisition with combined parallel imaging and temporal compressed sensing reconstruction was implemented to achieve accelerated preclinical 4D flow MRI. In order to increase the accuracy of the measured velocities, a quantitative evaluation of different temporal regularization weights for the compressed sensing reconstruction based on velocity instead of magnitude data is performed. A 3D radial retrospectively triggered phase contrast sequence with a combined parallel imaging and compressed sensing reconstruction with temporal regularization was developed. It was validated in a phantom and in vivo (C57BL/6 J mice), against an established fully sampled Cartesian sequence. Different undersampling factors (USFs [12, 15, 20, 30, 60]) were evaluated, and the effect of undersampling was analyzed in detail for magnitude and velocity data. Temporal regularization weights λ were evaluated for different USFs. Acceleration factors of up to 20 compared with full Nyquist sampling were achieved. The peak flow differences compared with the Cartesian measurement were the following: USF 12, 3.38%; USF 15, 4.68%; USF 20, 0.95%. The combination of 3D radial center-out trajectories and compressed sensing reconstruction is robust against motion and flow artifacts and can significantly reduce measurement time to 30 min at a resolution of 180 µm3 . Concisely, radial acquisition with combined compressed sensing and parallel imaging proved to be an excellent method for analyzing complex flow patterns in mice.


Assuntos
Aorta/diagnóstico por imagem , Hemorreologia , Imageamento por Ressonância Magnética , Aceleração , Animais , Modelos Animais de Doenças , Processamento de Imagem Assistida por Computador , Camundongos Endogâmicos C57BL , Camundongos Knockout , Imagens de Fantasmas , Pulso Arterial , Reprodutibilidade dos Testes
15.
Fetal Diagn Ther ; 47(5): 354-362, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32062652

RESUMO

Human fetal circulatory physiology has been investigated extensively using grey-scale ultrasound, which provides excellent visualization of cardiac anatomy and function, while velocity profiles in the heart and vessels can be interrogated using Doppler. Measures of cerebral and placental vascular resistance, as well as indirect measures of intracardiac pressure obtained from the velocity waveform in the ductus venosus are routinely used to guide the management of fetal cardiovascular and placental disease. However, the characterization of some key elements of cardiovascular physiology such as vessel blood flow and the oxygen content of blood in the arteries and veins, as well as fetal oxygen delivery and consumption are not readily measured using ultrasound. To study these parameters, we have historically relied on data obtained using invasive measurements made in animal models, which are not equivalent to the human in every respect. Over recent years, a number of technical advances have been made that have allowed us to examine the human fetal circulatory system using cardiovascular magnetic resonance (CMR). The combination of vessel blood flow measurements made using cine phase contrast magnetic resonance imaging and vessel blood oxygen saturation and hematocrit measurements made using T1 and T2 mapping have enabled us to emulate those classic fetal sheep experiments defining the distribution of blood flow and oxygen transport across the fetal circulation in the human fetus. In addition, we have applied these techniques to study the relationship between abnormal fetal cardiovascular physiology and fetal development in the setting of congenital heart disease and placental insufficiency. CMR has become an important diagnostic tool in the assessment of cardiovascular physiology in the setting of postnatal cardiovascular disease, and is now being applied to the fetus to enhance our understanding of normal and abnormal fetal circulatory physiology and its impact on fetal well-being.


Assuntos
Feto/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética/métodos , Feminino , Feto/irrigação sanguínea , Feto/fisiopatologia , Cardiopatias Congênitas/fisiopatologia , Humanos , Oximetria/métodos , Gravidez
16.
Magn Reson Med ; 81(6): 3662-3674, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30761599

RESUMO

PURPOSE: To develop a patient-specific respiratory motion correction technique with true 100% acquisition efficiency. METHODS: A short training scan consisting of a series of single heartbeat images, each acquired with a preceding diaphragmatic navigator, was performed to fit a model relating the patient-specific 3D respiratory motion of the heart-to-diaphragm position. The resulting motion model was then used to update the imaging plane in real-time to correct for translational motion based on respiratory position provided by the navigator. The method was tested in a group of 11 volunteers with 5 separate free-breathing acquisitions: FB, no motion correction; FB-TF, free breathing with a linear tracking factor; Nav Gate, navigator gating; Nav Gate-TF, navigator gating with a tracking factor; and PROCO, prospective motion correction (proposed). Each acquisition lasted for 50 accepted heartbeats, where non-gated scans had a 100% acceptance rate, and gated scans accepted data only within a ±4 mm navigator window. Retrospective image registration was used to measure residual motion and determine the effectiveness of each method. RESULTS: PROCO reduced the range/RMSE of residual motion to 4.08 ± 1.4/0.90 ± 0.3 mm, compared to 10.78 ± 6.9/2.97 ± 2.2 mm for FB, 5.32 ± 2.92/1.24 ± 0.8 mm for FB-TF, 4.08 ± 1.6/0.93 ± 0.4 mm for Nav Gate, and 2.90 ± 1.0/0.63 ± 0.2 mm for Nav Gate-TF. Nav Gate and Nav Gate-TF reduced scan efficiency to 48.84 ± 9.31% and 54.54 ± 10.12%, respectively. CONCLUSION: PROCO successfully limited the residual motion in single-shot imaging to the level of traditional navigator gating while maintaining 100% acquisition efficiency.


Assuntos
Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Modelagem Computacional Específica para o Paciente , Técnicas de Imagem de Sincronização Respiratória/métodos , Adulto , Técnicas de Imagem Cardíaca/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Movimento/fisiologia , Adulto Jovem
17.
Magn Reson Med ; 81(4): 2424-2438, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30431176

RESUMO

PURPOSE: Background phase offsets in phase-contrast MRI are often corrected using polynomial regression; however, correction performance degrades when temporally invariant outliers such as steady flow or spatial wrap-around artifact are present. We describe and validate an iterative method called automatic rejection of temporally invariant outliers (ARTO), which excludes these outliers from the fitting process. METHODS: The ARTO method iteratively removes pixels with large polynomial regression errors analyzed by a Gaussian mixture model fitting of the residual distribution. A total of 150 trials of a simulated phantom (75 with wrap-around artifact) and 125 phase-contrast MRI cines from 22 healthy subjects (48 with wrap-around artifact) were used for validation. Background phase offsets were corrected using second-order weighted regularized least squares (WRLS) with and without ARTO. Flow volumes after WRLS and WRLS+ARTO corrections were compared with the known truth (phantom) and stationary phantom reference (in vivo) using Bland-Altman analysis. The ratio between the pulmonary flow and the systemic flow was also computed in a subset of 6 subjects. RESULTS: In the simulated phantom, compared with WRLS and no correction, correction with WRLS+ARTO produced superior agreement in volumetric flow quantification with the known truth. In vivo, WRLS+ARTO also produced superior agreement with stationary phantom-corrected volumetric flow compared with WRLS and no correction. In data sets with wrap-around artifact, WRLS produced significantly larger variance in the pulmonary flow and systemic flow ratio than stationary phantom correction (P = .0008). CONCLUSION: The proposed method provides automatic exclusion of temporally invariant outliers and produces flow quantification results comparable to stationary phantom correction.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Adulto , Algoritmos , Aorta Torácica/diagnóstico por imagem , Artefatos , Simulação por Computador , Voluntários Saudáveis , Hemodinâmica , Humanos , Análise dos Mínimos Quadrados , Modelos Teóricos , Distribuição Normal , Estudos Prospectivos , Artéria Pulmonar/diagnóstico por imagem , Análise de Regressão , Volume Sistólico , Adulto Jovem
18.
J Magn Reson Imaging ; 49(5): 1222-1235, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30614102

RESUMO

Our purpose is to provide an overview and to systematically review the strengths and limitations of studies on pediatric and adolescent normal values for cardiovascular MRI parameters. A literature search was performed within the National Library of Medicine using the following keywords: normal, reference values, cardiovascular magnetic resonance imaging, and children/pediatric. Eleven published studies evaluating cardiovascular MRI measurements in normal children were included in the present analysis. Our results revealed reasonable consistencies in the protocols employed for cardiovascular MRI. Inter- and intraobserver variability analyses were performed in most studies and generally showed acceptable reproducibility. However, several numerical and methodological limitations emerged. Besides small sample sizes (the largest study enrolled 114 subjects), data for some structures (pulmonary arteries, aortic arch) were limited, and neonates/infants were poorly represented (eg, only two studies). There was heterogeneity regarding measurement normalization (eg, for gender, age, or both), and data were mostly expressed as mean values, while z-scores (commonly used in pediatric echocardiography) were rarely employed. Theoretically, a z-score or a standard deviation of ±2 is considered pathological. Furthermore, differences among races and ethnic groups were not evaluated. In conclusion, our analyses revealed an important need for generation of pediatric and adolescent cardiovascular MRI nomograms built over a wide population of healthy children, using consistent methodologies and with consideration of potentially relevant confounders. More data on expected abnormal values in specific CHD populations (eg, univentricular hearts) also need to be defined. Level of Evidence: 2 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2019;49:1222-1235.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Nomogramas , Adolescente , Criança , Feminino , Coração/diagnóstico por imagem , Cardiopatias Congênitas/terapia , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes
19.
Circulation ; 135(16): 1494-1505, 2017 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-28159799

RESUMO

BACKGROUND: Although small elevations of high-sensitive cardiac troponin T (hs-cTnT) are associated with incident heart failure (HF) in the general population, the underlying mechanisms are not well defined. Evaluating the association of hs-cTnT with replacement fibrosis and progression of structural heart disease before symptoms is fundamental to understanding the potential of this biomarker in a HF prevention strategy. METHODS: We measured hs-cTnT at baseline among 4986 participants in MESA (Multi-Ethnic Study of Atherosclerosis), a cohort initially free of overt cardiovascular disease (CVD). Cardiac magnetic resonance imaging was performed at baseline. Repeat cardiac magnetic resonance was performed 10 years later among 2831 participants who remained free of interim CVD events; of these, 1723 received gadolinium-enhanced cardiac magnetic resonance for characterization of replacement fibrosis by late gadolinium enhancement. Progression of subclinical CVD was defined by 10-year change in left ventricular structure and function. Associations of hs-cTnT with incident HF, CV-related mortality, and coronary heart disease were estimated using Cox regression models. RESULTS: Late gadolinium enhancement for replacement fibrosis was detectable in 6.3% participants without interim CVD events by follow-up cardiac magnetic resonance. A graded association was observed between higher baseline hs-cTnT categories and late gadolinium enhancement (≥7.42 ng/L versus 12% (highest category versus

Assuntos
Aterosclerose/sangue , Aterosclerose/diagnóstico , Insuficiência Cardíaca/diagnóstico , Troponina T/metabolismo , Idoso , Idoso de 80 Anos ou mais , Aterosclerose/patologia , Etnicidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Circulation ; 135(22): 2106-2115, 2017 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-28351901

RESUMO

BACKGROUND: Current guidelines only recommend the use of an implantable cardioverter defibrillator in patients with dilated cardiomyopathy for the primary prevention of sudden cardiac death (SCD) in those with a left ventricular ejection fraction (LVEF) <35%. However, registries of out-of-hospital cardiac arrests demonstrate that 70% to 80% of such patients have an LVEF >35%. Patients with an LVEF >35% also have low competing risks of death from nonsudden causes. Therefore, those at high risk of SCD may gain longevity from successful implantable cardioverter defibrillator therapy. We investigated whether late gadolinium enhancement (LGE) cardiovascular magnetic resonance identified patients with dilated cardiomyopathy without severe LV systolic dysfunction at high risk of SCD. METHODS: We prospectively investigated the association between midwall LGE and the prespecified primary composite outcome of SCD or aborted SCD among consecutive referrals with dilated cardiomyopathy and an LVEF ≥40% to our center between January 2000 and December 2011 who did not have a preexisting indication for implantable cardioverter defibrillator implantation. RESULTS: Of 399 patients (145 women, median age 50 years, median LVEF 50%, 25.3% with LGE) followed for a median of 4.6 years, 18 of 101 (17.8%) patients with LGE reached the prespecified end point, compared with 7 of 298 (2.3%) without (hazard ratio [HR], 9.2; 95% confidence interval [CI], 3.9-21.8; P<0.0001). Nine patients (8.9%) with LGE compared with 6 (2.0%) without (HR, 4.9; 95% CI, 1.8-13.5; P=0.002) died suddenly, whereas 10 patients (9.9%) with LGE compared with 1 patient (0.3%) without (HR, 34.8; 95% CI, 4.6-266.6; P<0.001) had aborted SCD. After adjustment, LGE predicted the composite end point (HR, 9.3; 95% CI, 3.9-22.3; P<0.0001), SCD (HR, 4.8; 95% CI, 1.7-13.8; P=0.003), and aborted SCD (HR, 35.9; 95% CI, 4.8-271.4; P<0.001). Estimated HRs for the primary end point for patients with an LGE extent of 0% to 2.5%, 2.5% to 5%, and >5% compared with those without LGE were 10.6 (95% CI, 3.9-29.4), 4.9 (95% CI, 1.3-18.9), and 11.8 (95% CI, 4.3-32.3), respectively. CONCLUSIONS: Midwall LGE identifies a group of patients with dilated cardiomyopathy and an LVEF ≥40% at increased risk of SCD and low risk of nonsudden death who may benefit from implantable cardioverter defibrillator implantation. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov. Unique identifier: NCT00930735.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/mortalidade , Morte Súbita Cardíaca/patologia , Gadolínio , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Adulto , Idoso , Cardiomiopatia Dilatada/epidemiologia , Endotélio Vascular/diagnóstico por imagem , Feminino , Seguimentos , Gadolínio/administração & dosagem , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/epidemiologia