Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Pulm Med ; 20(1): 208, 2020 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-32762669

RESUMO

BACKGROUND: The present study aimed to assess the value of bronchial and cavity contraction percentages in differentiating benign and malignant pulmonary cavities. METHODS: Forty-two patients with pulmonary cavities were scanned by dual-phase computed tomography (CT). Then, the cavity and bronchial contraction percentages were respectively measured, the differences between the benign and malignant cavities were compared, and the best diagnostic critical point for differentiating benign and malignant cavities was obtained through the receiver operator characteristic (ROC) curve of the diagnostic test. RESULTS: The contraction percentage of the bronchial end with benign cavities was significantly higher than that of the bronchial end with malignant cavities (P < 0.001). The contraction percentage was significantly higher in the benign group than in the malignant group (P < 0.001). The ROC analysis revealed that the sensitivity and specificity of the bronchial contraction percentage was 90.50 and 86.40%, respectively, while the sensitivity and specificity of the cavity contraction percentage was 90.50 and 90.90%, respectively. CONCLUSION: The dual-phase CT scanning of the bronchial and cavity contraction percentage can distinguish between benign and malignant cavities.


Assuntos
Brônquios/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Brônquios/patologia , Diagnóstico Diferencial , Feminino , Humanos , Pneumopatias/etiologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/etiologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade
2.
Cureus ; 15(5): e38463, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37273347

RESUMO

Background This study aims to evaluate dosimetric changes that happened during the first month after GammaTile surgically targeted radiation therapy (STaRT) for gliomas due to Cesium-131 (Cs-131) seed displacement caused by cavity shrinkage in brain brachytherapy. Methodology In this study, 10 glioma patients had 4-11 GammaTiles placed along the resection bed after maximal safe resection during craniotomy. Each GammaTile is composed of four Cs-131 seeds embedded in a biodegradable collagen sponge to minimize seed movement and maintain seed-to-cavity surface distance. The Cs-131 seed positions were identified using VariSeed on day one. On day 30, post-implant computed tomography (CT) images and dosimetry parameters were calculated. An iterative closest point (ICP) algorithm was used to compute rigid transformation between the day one and day 30 seed clouds. The seed displacement was calculated after registration. The volume receiving 100% of the prescription dose (V100), the dose received by 90% of the planning target volume (D90_PTV), the planning target volume receiving 100% of the prescription dose (V100_PTV), and the dose to organs at risk (OARs) were calculated for both CT images to determine the dosimetric changes from any seed displacement. Results The mean seed displacement of 1.8 ± 1.0 mm for all patients was observed between day one and day 30. The maximum seed displacement for each patient ranged from 2.3 mm to 7.3 mm. The mean V100 difference between day one and day 30 was 2.5 cc (range = 0.5-6.5 cc). The mean D90_PTVs were 95.5% (range = 69.0%-131.0%) and 98.1% (range = 19.9%-149.0%) on day one and day 30, respectively. The mean V100_PTVs were 88.4% (range = 81.3%-99.1%) and 87.9% (range = 47.0%-99.7%) on day one and day 30, respectively. On day one, the brainstem dose was 63.5 Gy for one case and 28.1 Gy for another case; while on day 30, the brainstem dose was 55.8 Gy and 20.6 Gy for the same patients, contributing to 7.7 Gy (12.8%) and 7.5 Gy (12.5%) dose reductions to brainstem for these patients, respectively. Only two patients received a dose to the optic nerves (34.1 Gy and 5.2 Gy). There were small changes (1.8 Gy and 0.5 Gy, respectively) in the dose to optic nerves when comparing the dose calculated on day one and the dose calculated on day 30 CT images. The same two patients received 30.4 Gy and 6.8 Gy to the chiasm, respectively. Small changes in the dose to the chiasm (≤1.1 Gy) were noted between day one and day 30. Conclusions A maximum seed displacement of up to 7.3 mm and a mean seed displacement of 1.8 mm caused by cavity shrinkage were observed during the first month after GammaTile STaRT for gliomas. There were noticeable changes in dosimetry parameters. Changes in the doses to OARs, particularly the brainstem, were large (up to 12.8% of the prescription dose). These changes in dosimetry should be considered when evaluating treatment outcomes and planning future GammaTile treatments.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa