Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
BMC Infect Dis ; 23(1): 11, 2023 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-36609225

RESUMO

BACKGROUND: The prevalence of resistant hospital infections in the intensive care unit (ICU) increases mortality and antibiotic resistance. COVID-19 pandemic may have unintended impact on nosocomial infections (NI) and the prevalence of resistant microorganism. METHODOLOGY: The present non-interventional study was performed by a pre and a post survey each lasting 8 months before (March-October 2019) and after (March-October 2020) the onset of COVID-19 pandemic in three ICU's, not allocated to COVID-19 patients, in Nemazee Hospital, Shiraz, Iran. The rates of the following nosocomial infections were compared at pre- and post-pandemic period: ventilator associated pneumonia (VAP), central line associated blood stream infection (CLABSI), catheter-associated urinary tract infections (CAUTI) and incidence of multiple drug resistance (MDR) pathogens. RESULTS: Pre-pandemic and pandemic incidence of VAP was 23.5 and 17.2 cases per 1000 device-days, respectively; an absolute decrease of 27%. The main reason for the decrease in the rate of VAP during the pandemic was a significant decrease in the rate of VAP caused by Acinetobacter baumannii; from 39 to 17% in total VAP episodes. The rate of VAP associated with other microorganisms remained relatively unchanged from 14.2 cases in pre-pandemic period to 14.3 cases per 1000 MV-days during the pandemic (P = 0.801). Pre-pandemic incidence of CLABSI was 7.3 cases and, in pandemic period, was 6.5 cases per 1000 device-days (IRR = 0.88, 95% CI 0.43-1.73, P = 0.703). Pre-pandemic incidence of CAUTI was 2 and in pandemic period, was 1.4 cases per 1000 device-days (IRR = 0.70, 95% CI 0.22-1.98, P = 0.469). CONCLUSION: The results of the present study showed a decrease in the incidence of VAP in critically ill non-COVID-19 patients during the pandemic compared to before the pandemic, especially regarding Acinetobacter baumannii.


Assuntos
Acinetobacter baumannii , COVID-19 , Infecções Relacionadas a Cateter , Infecção Hospitalar , Pneumonia Associada à Ventilação Mecânica , Infecções Urinárias , Humanos , Infecção Hospitalar/epidemiologia , Pandemias , Incidência , Estudos Prospectivos , COVID-19/epidemiologia , Infecções Relacionadas a Cateter/epidemiologia , Unidades de Terapia Intensiva , Pneumonia Associada à Ventilação Mecânica/epidemiologia , Hospitais de Ensino , Infecções Urinárias/epidemiologia , Resistência a Múltiplos Medicamentos , Catéteres
2.
Clin Infect Dis ; 74(10): 1748-1754, 2022 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-34370014

RESUMO

BACKGROUND: The profound changes wrought by coronavirus disease 2019 (COVID-19) on routine hospital operations may have influenced performance on hospital measures, including healthcare-associated infections (HAIs). We aimed to evaluate the association between COVID-19 surges and HAI and cluster rates. METHODS: In 148 HCA Healthcare-affiliated hospitals, from 1 March 2020 to 30 September 2020, and a subset of hospitals with microbiology and cluster data through 31 December 2020, we evaluated the association between COVID-19 surges and HAIs, hospital-onset pathogens, and cluster rates using negative binomial mixed models. To account for local variation in COVID-19 pandemic surge timing, we included the number of discharges with a laboratory-confirmed COVID-19 diagnosis per staffed bed per month. RESULTS: Central line-associated blood stream infections (CLABSI), catheter-associated urinary tract infections (CAUTI), and methicillin-resistant Staphylococcus aureus (MRSA) bacteremia increased as COVID-19 burden increased. There were 60% (95% confidence interval [CI]: 23-108%) more CLABSI, 43% (95% CI: 8-90%) more CAUTI, and 44% (95% CI: 10-88%) more cases of MRSA bacteremia than expected over 7 months based on predicted HAIs had there not been COVID-19 cases. Clostridioides difficile infection was not significantly associated with COVID-19 burden. Microbiology data from 81 of the hospitals corroborated the findings. Notably, rates of hospital-onset bloodstream infections and multidrug resistant organisms, including MRSA, vancomycin-resistant enterococcus, and Gram-negative organisms, were each significantly associated with COVID-19 surges. Finally, clusters of hospital-onset pathogens increased as the COVID-19 burden increased. CONCLUSIONS: COVID-19 surges adversely impact HAI rates and clusters of infections within hospitals, emphasizing the need for balancing COVID-related demands with routine hospital infection prevention.


Assuntos
Bacteriemia , COVID-19 , Infecções Relacionadas a Cateter , Infecção Hospitalar , Staphylococcus aureus Resistente à Meticilina , Pneumonia Associada à Ventilação Mecânica , Infecções Urinárias , Enterococos Resistentes à Vancomicina , Bacteriemia/epidemiologia , Bacteriemia/prevenção & controle , COVID-19/epidemiologia , Teste para COVID-19 , Infecções Relacionadas a Cateter/prevenção & controle , Infecção Hospitalar/microbiologia , Atenção à Saúde , Humanos , Pandemias , Pneumonia Associada à Ventilação Mecânica/microbiologia , Infecções Urinárias/epidemiologia
3.
J Intensive Care Med ; 29(3): 165-74, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23753223

RESUMO

BACKGROUND: Implementing best practice guidelines for ventilator-associated pneumonia (VAP) and central line-associated blood stream infection (CLA-BSI) has variable success. Our institution was concerned with high rates of VAP and CLA-BSI. This retrospective study was undertaken to see whether implementation of the below practices would reduce the rates of VAP and CLA-BSI without resorting to more expensive interventions such as subglottic endotracheal (ET) tube suctioning or silver-impregnated ET tubes. We utilized easily collectable data (standardized infection ratios [SIRs]) to rapidly assess whether interventions already in place were successful. This avoided cumbersome data collection and review. METHODS: Retrospective data review calculated SIRs using National Healthcare Safety Network benchmarks. Rates and SIRs were compared using z tests with P values <.05 considered statistically significant. This data review attempted to examine the impact of education campaigns, staff meetings, in-services, physician checklist, nurse checklist, charge nurse checklist implementation, and chlorhexidine gluconate oral care addition to the VAP bundle. Additionally, central line insertion required nursing supervision, a checklist, and physician signature. RESULTS: The incidence rate of VAP went from 9.88 occurrences/1000 vent days in 2009 to 0 occurrences/1000 vent days in 2010 (P < .001). The CLA-BSI occurrences/1000 line days were 2.86 in 2009 and 0.97 in 2010 (P = .0187). The SIR for VAP was 4.12 in 2009 and 0 in 2010 (P < .001). For CLA-BSI, the SIR was 1.1 in 2009 and 0.37 in 2010 (P = .04). CONCLUSIONS: Efforts to improve physician, patient, and staff education, and checklist implementation resulted in a decrease in VAP and CLA-BSI. This study confirms the applicability of best practice guidelines and suggests a benefit to the use of checklists. We utilize a practical approach for examining the success of these changes.


Assuntos
Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Pessoal de Saúde/educação , Pneumonia Associada à Ventilação Mecânica/prevenção & controle , Sepse/prevenção & controle , Ventiladores Mecânicos/efeitos adversos , Cateterismo Venoso Central/métodos , Lista de Checagem , Clorexidina/análogos & derivados , Clorexidina/uso terapêutico , Infecção Hospitalar/prevenção & controle , Humanos , Avaliação de Resultados em Cuidados de Saúde , Pneumonia Associada à Ventilação Mecânica/epidemiologia , Estudos Retrospectivos , Sepse/epidemiologia
4.
Nutrients ; 16(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38613123

RESUMO

Nosocomial infections are a frequent and serious problem in extremely low birth weight (ELBW) infants. Donor human milk (DHM) is the best alternative for feeding these babies when mother's own milk (MOM) is not available. Recently, a patented prototype of a High-Temperature Short-Time (HTST) pasteurizer adapted to a human milk bank setting showed a lesser impact on immunologic components. We designed a multicentre randomized controlled trial that investigates whether, in ELBW infants with an insufficient MOM supply, the administration of HTST pasteurized DHM reduces the incidence of confirmed catheter-associated sepsis compared to DHM pasteurized with the Holder method. From birth until 34 weeks postmenstrual age, patients included in the study received DHM, as a supplement, pasteurized by the Holder or HTST method. A total of 213 patients were randomized; 79 (HTST group) and 81 (Holder group) were included in the analysis. We found no difference in the frequency of nosocomial sepsis between the patients of the two methods-41.8% (33/79) of HTST group patients versus 45.7% (37/81) of Holder group patients, relative risk 0.91 (0.64-1.3), p = 0.62. In conclusion, when MOM is not available, supplementing during admission with DHM pasteurized by the HTST versus Holder method might not have an impact on the incidence of catheter-associated sepsis.


Assuntos
Recém-Nascido de Peso Extremamente Baixo ao Nascer , Sepse , Lactente , Recém-Nascido , Humanos , Leite Humano , Temperatura , Suplementos Nutricionais , Sepse/epidemiologia , Sepse/prevenção & controle
5.
Front Pediatr ; 12: 1395395, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38756973

RESUMO

Objective: This study aims to assess the comparative effectiveness of a conventional splitting needle or a peelable cannula vs. the modified Seldinger technique (MST) by utilizing a dedicated micro-insertion kit across various clinically significant metrics, including insertion success, complications, and catheter-related infections. Methods: We conducted a retrospective observational cohort study using an anonymized data set spanning 3 years (2017-2019) in a large tertiary-level neonatal intensive care unit in Qatar. Results: A total of 1,445 peripherally inserted central catheter (PICC) insertion procedures were included in the analysis, of which 1,285 (89%) were successful. The primary indication for insertion was mainly determined by the planned therapy duration, with the saphenous vein being the most frequently selected blood vessel. The patients exposed to MST were generally younger (7 ± 15 days vs. 11 ± 26 days), but exhibited similar mean weights and gestational ages. Although not statistically significant, the MST demonstrated slightly higher overall and first-attempt insertion success rates compared to conventional methods (91 vs. 88%). However, patients undergoing conventional insertion techniques experienced a greater incidence of catheter-related complications (p < 0.001). There were 39 cases of catheter-related bloodstream infections (CLABSI) in the conventional group (3.45/1,000 catheter days) and eight cases in the MST group (1.06/1,000 catheter days), indicating a statistically significant difference (p < 0.001). Throughout the study period, there was a noticeable shift toward the utilization of the MST kit for PICC insertions. Conclusion: The study underscores the viability of MST facilitated by an all-in-one micro kit for neonatal PICC insertion. Utilized by adept and trained inserters, this approach is associated with improved first-attempt success rates, decreased catheter-related complications, and fewer incidences of CLABSI. However, while these findings are promising, it is imperative to recognize potential confounding factors. Therefore, additional prospective multicenter studies are recommended to substantiate these results and ascertain the comprehensive benefits of employing the all-in-one kit.

6.
Am J Infect Control ; 44(12): 1458-1461, 2016 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-27908432

RESUMO

BACKGROUND: Peripherally inserted central catheters (PICCs) are a commonly used central intravenous (IV) access device, which can be associated with significant complications. Midline catheters (MCs) are peripheral IV access devices that may reduce the need for central lines and hence decrease central line-associated bloodstream infections. The objective of this study is to compare the utilization and safety of PICCs and MCs. METHODS: This was a retrospective study comparing the use and outcomes of PICCs and MCs at a large academic medical center between January and May 2015. Data were collected using electronic medical records and IV team insertion data. Statistical software was used for analysis. RESULTS: A total of 206 PICCs and 200 MCs were inserted in 367 patients within the study duration. Patients with MCs were more likely to have complications than those with PICCs (19.5% vs 5.8%, P < .0001). CONCLUSIONS: MCs were associated with a higher risk of non-life-threatening complications versus PICCs, which showed fewer but more serious complications, including bacteremia. The decision to move toward more use of MCs is not without risk. Institutions should continue to review the utilization and safety data of IV catheter use to determine the most appropriate use of these devices.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Sepse/epidemiologia , Sepse/etiologia , Centros Médicos Acadêmicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
7.
China Medical Equipment ; (12): 52-55, 2017.
Artigo em Chinês | WPRIM | ID: wpr-620723

RESUMO

Objective: To explore the clinical effect of two disinfectors on prevention for central line-associated blood stream infection (CLABSI) in hemodialysis. Methods: 168 patients received blood purification through central venous indwelling catheter were divided into control group (82 cases) and observation group (86 cases) as random table. The patients of control group were disinfected by using iodophor disinfectant on central venous catheter and skin around puncture, while the patients of observation group were disinfected by using medical chlorhexidine gluconate (2% chlorhexidine gluconate, 70% isopropanol and 28%injection) on the same positions. In different stages, before and after central venous indwelling catheter and 24 hours after central venous indwelling catheter, the colony count and incidence of CLABSI of patients between two groups were compared. Results: There was no significant difference between the two groups for colony count around puncture before central venous indwelling catheter (t=-1.478, P>0.05). The colony count of observation group was lower than that of control group after 24 hours of disinfection. According to the diagnosis standards of CLABSI, the incidence of CLABSI in observation group was significant lower than that in control group (x2=6.048, P<0.05). Conclusion: The disinfector of chlorhexidine gluconate can decrease the incidence of CLABSI in hemodialysis and its bacteriostatic time is longer than that of iodophor disinfectant. Therefore, this method is worthy for promotion in clinical practice.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa