Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Catheter Cardiovasc Interv ; 104(1): 34-43, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38713867

RESUMO

Hypertension continues to be a prominent, avoidable factor contributing to major vascular issues on a global scale. Even with lifestyle adjustments and more aggressive medical treatments, maintaining optimal blood pressure levels remains challenging. This challenge has driven the emergence of device-oriented approaches to address hypertension. To assess the safety and efficacy of the Recor Paradise Ultrasound Renal Denervation System, the Circulatory System Devices Panel was convened by the US Food and Drug Administration (FDA). This manuscript provides a condensed overview of the information put forth by the sponsor and the FDA, along with an account of the considerations and conversations that took place during the meeting.


Assuntos
Pressão Sanguínea , Aprovação de Equipamentos , Hipertensão , Artéria Renal , Simpatectomia , United States Food and Drug Administration , Humanos , Estados Unidos , Simpatectomia/efeitos adversos , Simpatectomia/instrumentação , Hipertensão/fisiopatologia , Hipertensão/cirurgia , Artéria Renal/inervação , Artéria Renal/diagnóstico por imagem , Resultado do Tratamento , Rim/irrigação sanguínea , Comitês Consultivos , Desenho de Equipamento , Fatores de Risco
2.
Artigo em Inglês | MEDLINE | ID: mdl-36640418

RESUMO

BACKGROUND: Invasive cardiac catheterization (CC) temporarily increases pain, discomfort, and anxiety. Procedural sedation is deployed to mitigate these symptoms, though practice varies. Research evaluating peri-procedural patient-reported outcomes is lacking. METHODS AND RESULTS: We randomized 175 patients undergoing CC to short interval ([SI] group, <6 min) or long interval ([LI] group, ≥6 min) time intervals between initial intravenous sedation and local anesthetic administration. Outcomes included: (1) total pain medication use, (2) patient-reported and behaviorally assessed pain and (3) patient satisfaction during outpatient CC. Generalized linear mixed effect models were used to evaluate the impact of treatment time interval on total medication utilization, pain, and satisfaction. Among enrollees the mean age was 62 (standard deviation [SD] = 13.4), a majority were male (66%), white (74%), and overweight (mean body mass index = 28.5 [SD = 5.6]). Total pain medication use did not vary between treatment groups (p = 0.257), with no difference in total fentanyl (p = 0.288) or midazolam (p = 0.292). Post-treatment pain levels and nurse-observed pain were not statistically significant between groups (p = 0.324 & p = 0.656, respectively. No significant differences with satisfaction with sedation were found between the groups (p = 0.95) Patient-reported pain, satisfaction and nurse-observed measures of pain did not differ, after adjustment for demographic and procedural factors. Analyses of treatment effect modification revealed that postprocedure self-reported pain levels varied systematically between individuals undergoing percutaneous coronary intervention (PCI) (SI = 2.2 [0.8, 3.6] vs. LI = 0.7 [-0.6, 2.0]) compared with participants not undergoing PCI (SI = 0.4 [-0.8, 1.7] vs. LI = 0.7 [-0.3, 1.6]) (p = 0.043 for interaction). CONCLUSION: No consistent treatment differences were found for total medication dose, pain, or satisfaction regardless of timing between sedation and local anesthetic. Treatment moderations were seen for patients undergoing PCI. Further investigation of how procedural and individual factors impact the patient experience during CC is needed.

3.
Catheter Cardiovasc Interv ; 101(1): 122-130, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36480805

RESUMO

Evaluative research in interventional cardiology has focused on clinical and technical outcomes. Inclusion of economic data can enhance evaluative research by quantifying the relative economic burden incurred by different therapies. When combined with clinical outcomes, cost data can provide a measure of value (e.g., marginal cost-effectiveness). In some select situations, cost data can also be used as surrogates for complexity of care and morbidity. In this narrative review, we aim to provide a framework for the application of cost data in clinical trials and observational research, detailing how to incorporate this kind of data into interventional cardiology research.


Assuntos
Cardiologia , Humanos , Análise Custo-Benefício , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 98(6): 1167-1176, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33847447

RESUMO

OBJECTIVES: To compare clinical outcomes of balloon-expandable (BE) and self-expanding (SE) transcatheter aortic valves (TAVs) up to 5 years. BACKGROUND: To date, no robust, comparative data of BE and SE TAVs at long-term are available. METHODS: We considered a total of 1,440 patients enrolled in the multicenter OBSERVANT study and undergoing transfemoral transcatheter aortic valve implantation (TF-TAVI) with either supra-annular SE (n = 830, 57.6%) and intra-annular BE (n = 610, 42.4%) valves. Clinical outcomes of the two groups were compared after adjustment using inverse probability of treatment weighting (IPTW) and confirmed by sensitivity analysis with propensity score matching. RESULTS: Patients receiving SE valve showed a higher all-cause mortality at 5 years (Kaplan-Meier estimates 52.3% vs. 47.7%; Hazard ratio [HR] 1.18, 95% confidence interval [CI] 1.01-1.38, p = .04). Landmark analyses showed that there was a not statistically significant reversal of risk excess against the BE group starting from 3 years after TAVI (3-5 years HR 0.97, 95% CI 0.76-1.25, p = .86). Post-procedural, moderate/severe paravalvular regurgitation (PVR)(HR 1.46, 95% CI 1.14-1.87; p < .01) and acute kidney injury (AKI)(HR 3.89, 95% CI 2.47-6.38; p < .01) showed to be independent predictors of 5-year all-cause mortality in multivariable analysis. CONCLUSIONS: Considering the intrinsic limitations of the OBSERVANT study, we found that patients undergoing TF-TAVI with a supra-annular SE valve had a higher all-cause mortality compared to those receiving an intra-annular BE valve at 5 years. A late catch up phenomenon of patients receiving the BE valve was observed beyond 3 years. Post-procedural moderate/severe PVR seems to play a crucial role in determining this finding. Comparative studies of new generation devices with longer follow-up are needed to evaluate the benefit of each specific TAV type.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 97(1): 157-164, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32497385

RESUMO

BACKGROUND: A history of cancer is incorporated into the surgical risk assessment of patients undergoing surgical aortic valve replacement through the Society for Thoracic Surgeons score. However, the prognostic significance of cancer in patients treated with transcatheter aortic valve replacement (TAVR) is unclear. As the cancer survivorship population increases, it is imperative to establish the efficacy and safety of TAVR in patients with severe symptomatic aortic stenosis (AS) and a history of malignancy. OBJECTIVES: The primary goal of this study was to assess the periprocedural outcomes and long-term mortality in patients with a history of cancer undergoing TAVR. METHODS: A systematic review of PubMed, MEDLINE, and EMBASE was conducted to identify studies reporting outcomes in patients with a history of malignancy undergoing TAVR. A meta-analysis was performed using a random-effects model with a primary outcome of all-cause mortality and cardiac mortality at the longest follow-up. On secondary analyses, procedural safety was assessed. RESULTS: A total of 13 observational studies with 10,916 patients were identified in the systematic review. Seven studies including 6,323 patients were included in the quantitative analysis. Short-term mortality (relative risk [RR] 0.61, 95%CI 0.36-1.01; p = .06) and long-term all-cause mortality (RR 1.24, 95%CI 0.95-1.63; p = .11) were not significantly different when comparing patients with and without a history of cancer. No significant difference in the rate of periprocedural complications including stroke, bleeding, acute kidney injury, and pacemaker implantation was noted. CONCLUSION: In patients with severe AS undergoing TAVR, a history of cancer was not associated with adverse short or long-term survival. Based on these findings, TAVR should be considered in all patients with severe symptomatic AS, irrespective of their history of malignancy.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Neoplasias , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 98(1): 97-106, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33686726

RESUMO

Social media allows interventional cardiologists to disseminate and discuss research and clinical cases in real-time, to demonstrate and learn innovative techniques, to build professional networks, and to reach out to patients and the general public. Social media provides a democratic platform for all participants to influence the conversation and demonstrate their expertise. This review addresses the use of social media for these purposes in interventional cardiology, as well as respect for patient privacy, how to get started on social media, the creation of high-impact social media content, and the role of traditional journals in the age of social media. In the future, we hope that interventional cardiology fellowship programs will incorporate social media training into their curricula. In addition, professional societies may adapt to the rapid dissemination of data on social media by developing processes to update guidelines more rapidly and more frequently.


Assuntos
Cardiologia , Mídias Sociais , Cardiologia/educação , Currículo , Humanos , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 96(1): 145-155, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32061033

RESUMO

Evidence-based recommendations for clinical practice are intended to help health care providers and patients make decisions, minimize inappropriate practice variation, promote effective resource use, improve clinical outcomes, and direct future research. The Society for Cardiovascular Angiography and Interventions (SCAI) has been engaged in the creation and dissemination of clinical guidance documents since the 1990s. These documents are a cornerstone of the society's education, advocacy, and quality improvement initiatives. The publications committee is charged with oversight of SCAI's clinical documents program and has created this manual of standard operating procedures to ensure consistency, methodological rigor, and transparency in the development and endorsement of the society's documents. The manual is intended for use by the publications committee, document writing groups, external collaborators, SCAI representatives, peer reviewers, and anyone seeking information about the SCAI documents program.


Assuntos
Comitês Consultivos/normas , Angiografia/normas , Cateterismo Cardíaco/normas , Procedimentos Endovasculares/normas , Manuais como Assunto/normas , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto/normas , Sociedades Médicas/normas , Medicina Baseada em Evidências/normas , Humanos , Redação/normas
8.
Catheter Cardiovasc Interv ; 95(7): E196-E200, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31313448

RESUMO

OBJECTIVES: Patient centeredness is an essential component of high-quality care, yet little is known regarding the patient experience during procedures performed in the cardiac catheterization lab. BACKGROUND: Available literature focuses on the safe delivery of sedation, but does not address patient-reported satisfaction or comfort. Further delineation of how procedural factors impact the patient experience is needed. METHODS: We conducted a retrospective, exploratory analysis of adult cardiac catheterization outpatients (n = 375) receiving physician ordered, nurse administered procedural sedation (benzodiazepine and/or opioids) between April and June, 2017. Data were abstracted from the procedural database, Electronic Health Record, and Press Ganey© surveys. RESULTS: The mean age was 63 (SD 12.2), a majority were male (n = 226; 60%), white (n = 271; 73%), and overweight (mean body mass index = 29, SD 6.8). Patient-reported satisfaction with pain control and perceived staff concern for comfort were >75th percentile (Press Ganey© survey), with no difference in preprocedure and postprocedure pain scores (p = .596). Intraprocedural medication dose range and mean frequency were highly variable: midazolam (0.25-5.5 mg; 1.48); fentanyl (12.5-200 mcg; 1.63); and hydromorphone (0.5-2.5 mg; 1.33). Median time interval between administration of initial sedation and local anesthetic was 6 min. Patients with longer intervals had less frequent dosing (p < .001) and less total procedural sedation (p < .001). Sensitivity analysis revealed that trainee/fellow involvement (p = .001), younger age (p = .002), and shorter time intervals (p < .001) were associated with increased frequency and larger total dose. CONCLUSIONS: Waiting to gain vascular access following administration of procedural was associated with less frequent subsequent dosing, lower overall administration, and similar patient satisfaction. Optimizing processes for administering periprocedural sedation may allow for less medication without impacting patient experience.


Assuntos
Analgésicos Opioides/uso terapêutico , Cateterismo Cardíaco/efeitos adversos , Hipnóticos e Sedativos/administração & dosagem , Manejo da Dor , Dor/tratamento farmacológico , Satisfação do Paciente , Idoso , Atitude do Pessoal de Saúde , Pesquisa Comparativa da Efetividade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor/diagnóstico , Dor/etiologia , Dor/psicologia , Avaliação de Resultados da Assistência ao Paciente , Estudos Retrospectivos
9.
Catheter Cardiovasc Interv ; 93(2): E90-E97, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30280476

RESUMO

OBJECTIVE: This study assessed the rate of major adverse renal or cardiac events (MARCE) when iohexol is used during interventional cardiovascular procedures compared to other low osmolar contrast media (LOCMs). BACKGROUND: Interventional cardiovascular procedures are often essential for diagnosis and treatment, the risk of MARCE should be considered. METHODS: Data were derived from the Premier Hospital Database January 1, 2010 through September 30, 2015. Patient encounters with an inpatient primary interventional cardiovascular procedure with a single LOCM (iohexol, ioversol, ioxilan, ioxaglate, or iopamidol) were included. The primary outcome was a composite endpoint of MARCE, which included: renal failure with dialysis, acute kidney injury (AKI) with or without dialysis, contrast induced AKI, acute myocardial infarction, angina, stent occlusion/thrombosis, stroke, transient ischemic attack, or death. Multivariable regression analysis was performed using the hospital fixed-effects specification to assess the relationship between MARCE and iohexol compared to other LOCMs, while controlling for patient demographics, comorbid conditions and reason for hospitalization. As a sensitivity analysis, direct comparisons of iohexol were made to other LOCMs. RESULTS: A total of 458,091 inpatient encounters met inclusion criteria of which 26% used iohexol and 74% used other LOCMs. Results of multivariable modeling revealed no differences in MARCE rates between iohexol and other LOCMs. When direct comparisons of iohexol vs. ioversol and iopamidol were modeled, no differences in MARCE nor the renal component of MARCE were found. CONCLUSIONS: In this retrospective multicenter study, there were no differences in MARCE events with iohexol compared to other LOCMs during inpatient interventional cardiovascular procedures.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Cateterismo Cardíaco/efeitos adversos , Transtornos Cerebrovasculares/induzido quimicamente , Meios de Contraste/efeitos adversos , Cardiopatias/induzido quimicamente , Iohexol/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Insuficiência Renal/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/mortalidade , Injúria Renal Aguda/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/mortalidade , Transtornos Cerebrovasculares/diagnóstico , Transtornos Cerebrovasculares/mortalidade , Transtornos Cerebrovasculares/terapia , Meios de Contraste/administração & dosagem , Bases de Dados Factuais , Feminino , Cardiopatias/diagnóstico , Cardiopatias/mortalidade , Cardiopatias/terapia , Humanos , Iohexol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/mortalidade , Diálise Renal , Insuficiência Renal/diagnóstico , Insuficiência Renal/mortalidade , Insuficiência Renal/terapia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Estados Unidos , Adulto Jovem
10.
Catheter Cardiovasc Interv ; 93(5): 859-874, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30896894

RESUMO

Until recently, evidence to support Patent Foramen Ovale (PFO) closure for secondary prevention of recurrent stroke has been controversial. Publication of high-quality evidence from randomized clinical trials and the subsequent FDA approval of two devices for percutaneous PFO closure is expected to increase the volume of PFO closure procedures not only in the United States but worldwide. As this technology is disseminated broadly to the public, ensuring the safe and efficacious performance of PFO closure is essential to mitigate risk and avoid unnecessary procedures. This document, prepared by a multi-disciplinary writing group convened by the Society for Cardiovascular Angiography and Interventions and including representatives from the American Academy of Neurology, makes recommendations for institutional infrastructure and individual skills necessary to initiate and maintain an active PFO/stroke program, with emphasis on shared decision making and patient-centered care.


Assuntos
Cateterismo Cardíaco , Educação de Pós-Graduação em Medicina , Embolia Paradoxal/prevenção & controle , Forame Oval Patente/terapia , Neurologistas/educação , Prevenção Secundária/educação , Acidente Vascular Cerebral/prevenção & controle , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Tomada de Decisão Clínica , Consenso , Embolia Paradoxal/diagnóstico por imagem , Embolia Paradoxal/etiologia , Embolia Paradoxal/fisiopatologia , Medicina Baseada em Evidências , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/fisiopatologia , Humanos , Segurança do Paciente , Recidiva , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/fisiopatologia , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 93(2): 222-230, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30144337

RESUMO

BACKGROUND: The risk of contrast-induced acute kidney injury (CI-AKI) increases in a nonlinear fashion with increasing volume of contrast media. Prior studies recommend limiting contrast volume to less than three times the estimated creatinine clearance (CC). Recently, a number of operators have reported successful percutaneous coronary intervention (PCI) using even lower volumes of contrast. OBJECTIVES: To evaluate the prevalence and outcomes associated with ultra-low contrast volume among patients undergoing PCI. METHODS: We assessed the prevalence and outcomes associated with use of ultra-low contrast volume among 75 393 patients undergoing PCI in Michigan between July 2014 and June 2017 in the BMC2 (Blue Cross Blue Shield of Michigan Cardiovascular Consortium) registry. Ultra-low contrast volume was defined as contrast volume less than or equal to the patient's estimated CC. Patients receiving dialysis at the time of the procedure were excluded. RESULTS: Ultra-low contrast volume was used in 13% of procedures with the majority of these patients being at low risk of renal complications. Compared with patients who received a contrast volume between one and three times the CC, use of ultra-low volume of contrast was associated with a significantly lower incidence of AKI (aOR 0.682, 95% CI 0.566-0.821, P < 0.001) and a lower incidence of need for dialysis (aOR = 0.341, 95% CI 0.165-0.704, P = 0.003). These benefits were most evident in the patients with a high baseline predicted risk of AKI. CONCLUSIONS: A small but clinically significant number of patients are treated with ultra-low contrast volume. Ultra-low contrast volume use is associated with a significant reduction in the incidence of AKI or need for dialysis. It may be prudent to consider this new threshold when performing PCI on patients who are at an increased risk of AKI.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Meios de Contraste/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Planos de Seguro Blue Cross Blue Shield , Meios de Contraste/administração & dosagem , Feminino , Humanos , Incidência , Masculino , Michigan/epidemiologia , Pessoa de Meia-Idade , Sistema de Registros , Diálise Renal , Fatores de Risco , Resultado do Tratamento
12.
Pediatr Cardiol ; 40(2): 445-453, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30506273

RESUMO

To stratify diverse procedure types into categories with similar radiation exposure in cardiac catheterization for congenital heart disease. Radiation exposures for a comprehensive list of specific procedure types and stratification of outcomes based on radiation risk are not currently available. Data between January 2014 and December 2015 were collected on all cases performed at sites participating in C3PO-QI (Congenital Cardiac Catheterization Outcomes Project-Quality Improvement Initiative) and 9 centers were included. Using expert consensus, 40 unique procedure types were defined by diagnostic characteristics or the intervention(s) performed, and dose area product (DAP) per kilogram of body weight (µGy × m2/kg) was summarized. Using empiric and consensus methods, three radiation risk categories were created. A total of 11,735 cases were included for analysis. Thirteen (n = 7918) procedure types with median DAP/kg < 100 were categorized in the low radiation exposure category (median DAP/kg 39). The medium exposure category (n = 1807) consisted of 16 procedure types with median DAP/kg values ranging 100 to < 200 (overall median DAP/kg 131). Finally, the high radiation exposure category (n = 1073) consisted of 11 procedure types with median DAP/kg ≥ 200 (overall median DAP/kg of 231). The radiation exposure risk categories created in this multi-center dataset are a critical step towards the development of a robust risk adjustment methodology for radiation exposure in catheterization for congenital heart disease.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Fluoroscopia/efeitos adversos , Cardiopatias Congênitas/cirurgia , Exposição à Radiação , Radiografia Intervencionista/efeitos adversos , Adolescente , Criança , Pré-Escolar , Consenso , Humanos , Lactente , Estudos Prospectivos , Melhoria de Qualidade , Doses de Radiação , Medição de Risco/métodos , Fatores de Risco , Adulto Jovem
13.
Catheter Cardiovasc Interv ; 91(7): 1354-1362, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29024382

RESUMO

OBJECTIVES: The objective is to compare the short-term (30 days) and late (12 months) vascular adverse events in patients undergoing transfemoral (TF)-transcatheter aortic valve replacement (TAVR) by surgical cut-down (SC) vs. percutaneous (PC) approaches. BACKGROUND: Programs continue to utilize both approaches in TF-TAVR. There are limited data comparing outcomes by SC vs. PC approaches and long-term effects of endovascular intervention facilitated hemostasis on late vascular adverse events. METHODS: A total of 146 men and women aged 79.7 ± 10.0 years with severe aortic stenosis deemed extreme or high risk for surgery underwent TAVR via TF access. 61 had SC and 85 had PC approaches. Valve Academic Research Consortium (VARC-2) outcomes were assessed at an average of 12.1 months after TAVR. RESULTS: Hospital length of stay (LOS) post-TAVR was shorter for the PC group compared to the SC group (5.1 ± 3.9 vs. 8.2 ± 6.6 days; P < 0.001). More patients were discharged directly to home in the PC than the SC group (85.9% vs. 68.9%, P < 0.05). At 30 days, there were 13/61 (21.3%) and 16/85 (18.8%; P < 0.05) of any vascular events, and 2/61 (3.3%) and 2/85 (2.4%; P = 0.73) major vascular events in the SC and PC groups, respectively. There was no difference in all-cause mortality between the SC (14/61; 23%) and PC groups [17/85 (20%); P = 0.34]. There was no difference in any [4/33 (12%) vs. 3/43 (7%); P = 0.84] or major vascular adverse events [1/33 (3%) vs. 1/43 (2%); P = 0.79] in subjects that underwent adjunctive endovascular intervention compared to those who did not, respectively. There were no statistically significant univariate or multivariate predictors of any vascular event at 12 months when comparing SC to PC groups. CONCLUSION: For TF TAVR, the PC approach, when compared to the SC approach, is associated with a shorter hospital LOS and higher rate of direct discharge to home with similar risk of vascular complications, late vascular adverse events, and all-cause mortality at 12 months.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Artéria Femoral/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Procedimentos Cirúrgicos Vasculares , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Tempo de Internação , Masculino , Alta do Paciente , Punções , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/mortalidade
15.
Catheter Cardiovasc Interv ; 89(4): 665-670, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27121130

RESUMO

OBJECTIVES: To evaluate radiation reduction by reducing fluoroscopy pulse rate in diagnostic cardiac catheterizations and percutaneous coronary interventions (PCI) as well as outcomes at 30 days and six months. BACKGROUND: Radiation exposure to the public at large has increased dramatically over the past three decades, and the cardiac catheterization laboratory is a large contributor. Fluoroscopy pulse rate is one way to decrease radiation exposure. METHODS: Fluoroscopy pulse rate was reduced from 10 pulses/sec (p/s) to 7.5 p/s as part of an internal quality improvement project. A retrospective analysis of all cardiac catheterizations was performed, evaluating Air KERMA at the interventional reference point (Ka, r ), Air KERMA area product (PKA ), procedural complications and major adverse cardiac events at 30 days and 6 months. RESULTS: In diagnostic catheterization median PKA (µGy·m2 ) and Ka,r (mGy) were significantly reduced (PKA - 5,613.3 vs. 4,400, P < 0.001; Ka,r - 703.0 vs. 621.0, P = 0.041). In PCI, median PKA and Ka,r were further reduced (PKA - 13,481.6 vs. 10,648.0, P < 0.001; Ka,r - 1787.0 vs. 1,459.0, P = 0.002). There was no difference in complications, fluoroscopy time or number of stents placed. There was no difference in MACE after adjustment for number of STEMIs. CONCLUSIONS: Reducing fluoroscopy pulse rates to 7.5 from 10 is an effective way to reduce patient radiation exposure across meaningful dose indices. A pulse rate of 7.5 p/s is safe, with no difference in complications or outcomes. A fluoroscopy pulse rate of 7.5 p/s should be given strong consideration for a new standard. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/métodos , Fluoroscopia/métodos , Lesões por Radiação/prevenção & controle , Medição de Risco/métodos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Pennsylvania/epidemiologia , Intervenção Coronária Percutânea , Doses de Radiação , Lesões por Radiação/epidemiologia , Estudos Retrospectivos , Fatores de Risco
17.
Catheter Cardiovasc Interv ; 90(2): 269-280, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28198573

RESUMO

OBJECTIVES: This study sought to update benchmark values to use a quality measure prospectively. BACKGROUND: Congenital Cardiac Catheterization Outcomes Project - Quality Improvement (C3PO-QI), a multi-center registry, defined initial radiation dose benchmarks retrospectively across common interventional procedures. These data facilitated a dose metric endorsed by the American College of Cardiology in 2014. METHODS: Data was collected prospectively by 9 C3PO-QI institutions with complete case capture between 1/1/2014 and 6/30/2015. Radiation was measured in total air kerma (mGy), dose area product (DAP) (µGy*M2 ), DAP per body weight, and fluoroscopy time (min), and reported by age group as median, 75th and 95th %ile for the following six interventional procedures: (1) atrial septal defect closure; (2) aortic valvuloplasty; (3) treatment of coarctation of the aorta; (4) patent ductus arteriosus closure; (5) pulmonary valvuloplasty; and (6) transcatheter pulmonary valve implantation. RESULTS: The study was comprised of 1,680 unique cases meeting inclusion criteria. Radiation doses were lowest for pulmonary valvuloplasty (age <1 yrs, median mGy: 59, DAP: 249) and highest in transcatheter pulmonary valve implantation (age >15 yrs, median mGy: 1835, DAP: 17990). DAP/kg standardized outcome measures across weights within an age group and procedure type significantly more than DAP alone. Radiation doses decreased for all procedures compared to those reported previously by both median and median weight-based percentile curves. These differences in radiation exposure were observed without changes in median fluoroscopy time. CONCLUSIONS: This study updates previously established benchmarks to reflect QI efforts over time. These thresholds can be applied for quality measurement and comparison. © 2017 Wiley Periodicals, Inc.


Assuntos
Benchmarking/normas , Cateterismo Cardíaco/normas , Cardiopatias Congênitas/terapia , Pediatria/normas , Doses de Radiação , Exposição à Radiação/normas , Radiografia Intervencionista/normas , Adolescente , Fatores Etários , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Masculino , Segurança do Paciente/normas , Estudos Prospectivos , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Sistema de Registros , Medição de Risco , Fatores de Risco , Estados Unidos
19.
Catheter Cardiovasc Interv ; 88(4): E103-E112, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26527352

RESUMO

OBJECTIVES: To evaluate how a comprehensive evidence-based clinical review by a multidisciplinary revascularization heart team on treatment decisions for revascularization in patients with complex coronary artery disease using SYNTAX scores combined with Society of Thoracic Surgeons-derived clinical variables can be additive to the utilization of Appropriate Use Criteria for coronary revascularization. BACKGROUND: Decision-making regarding the use of revascularization for coronary artery disease has come under major scrutiny due to inappropriate overuse of revascularization. There is little data in routine clinical practice evaluating how a structured, multidisciplinary heart team approach may be used in combination with the Appropriate Use Criteria for revascularization. METHODS: From May 1, 2012 to January 1, 2015, multidisciplinary revascularization heart team meetings were convened to discuss evidence-based management of 301 patients with complex coronary artery disease. Heart team recommendations were adjudicated with the Appropriate Use Criteria for coronary revascularization for each clinical scenario using the Society for Cardiovascular Angiography and Interventions' Quality Improvement Toolkit (SCAI-QIT) Appropriate Use Criteria App. RESULTS: Concordance of the Heart Team to Appropriate Use Criteria had a 99.3% appropriate primary indication for coronary revascularization. Among patients who underwent percutaneous revascularization, 34.9% had an inappropriate or uncertain indication as recommended by the Heart Team. Patients with uncertain or inappropriate percutaneous coronary interventions had significantly higher SYNTAX score (27.3 ± 6.6; 28.5 ± 5.5; 19.2 ± 6; P < 0.0001) and Society of Thoracic Surgeons-Predicted Risk of Mortality (6.1% ± 4.7%; 8.1% ± 6.3%; 3.7% ± 4.1%; P < 0.0081) compared to appropriate indications, frequently had concomitant forms of advanced comorbidities and frailty in the setting of symptomatic coronary artery disease. CONCLUSIONS: A formal, multidisciplinary revascularization heart team can provide proper validation for clinical decisions and should be considered in combination with the Appropriate Use Criteria for coronary revascularization to formulate revascularization strategies for individuals in a patient-centered fashion. © 2015 Wiley Periodicals, Inc.


Assuntos
Doença da Artéria Coronariana/terapia , Técnicas de Apoio para a Decisão , Medicina Baseada em Evidências , Revascularização Miocárdica , Equipe de Assistência ao Paciente , Seleção de Pacientes , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Procedimentos Clínicos , Medicina Baseada em Evidências/normas , Feminino , Mortalidade Hospitalar , Humanos , Comunicação Interdisciplinar , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica/efeitos adversos , Revascularização Miocárdica/mortalidade , Revascularização Miocárdica/normas , Equipe de Assistência ao Paciente/normas , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 85(6): 1058-65, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25413379

RESUMO

BACKGROUND: Patent foramen ovale (PFO) has been associated with paradoxical embolism leading to stroke/transient ischemic attack, migraine, and neurological decompression sickness. In search for the optimal device that would achieve effective clinical closure with minimal complications, a better device selection based on PFO anatomy and improvements in device design is needed. The Flatstent is a new device designed to treat the highly prevalent long-tunnel PFOs from within, minimizing the amount of material left behind in an attempt to reduce device-related complications. The objective is to compare the safety and efficacy of the novel Flatstent versus the conventional umbrella devices in the transcatheter closure of PFO in a nonrandomized, retrospective, single-center study. METHODS: Between March 2010 and March 2013, 88 patients underwent PFO closure at The Heart Hospital, London with either the novel Flatstent or one of the four conventionally used umbrella devices (GORE Helex Septal Occluder, Occlutech Figulla Flex, Biostar Septal Occluder, and Amplatzer PFO Occluder) depending on their PFO anatomy. Patients were then evaluated with contrast transthoracic echocardiography (TTE) and/or transoesophageal echocardiography (TOE) at 6 weeks and 1 year after the procedure. The residual shunt and complication rates between the Flatstent and umbrella devices were compared. RESULTS: The Flatstent was used in 27 patients (30.7%), whereas 61 patients (69.3%) received one of the four umbrella devices. Primary efficacy point of clinical closure defined as grade 0 or grade 1; residual shunt was achieved in 81.3% in the Flatstent cohort and 80.3% in the umbrella device group at 6 weeks follow-up. At 1 year, the clinical closure rates reached 92.6 and 91.8%. There were two device embolizations, one in each cohort during the immediate postoperative period (<24 hrs), with successful retrieval. One patient in the umbrella device group developed transient atrial fibrillation, which was controlled medically. Event recurrence rate was 0% at 1 year. CONCLUSION: No difference was found in closure or complication rates between the Flatstent and the umbrella devices. With appropriate preassessment of the PFO anatomy, the Flatstent works as a safe and effective method of treating the PFO from within the tunnel, especially in those with long-tunnel PFOs. Longer follow-up is needed to establish superiority.


Assuntos
Cateterismo Cardíaco/métodos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Desenho de Prótese , Dispositivo para Oclusão Septal , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/instrumentação , Estudos de Coortes , Ecocardiografia Transesofagiana/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Análise de Regressão , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Resultado do Tratamento , Reino Unido , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa