RESUMO
OBJECTIVE: In this study, we aimed to assess the predictive value of transesophageal echocardiography (TEE) combined with contrast transthoracic echocardiography (cTTE) for embolic stroke of undetermined source (ESUS). METHODS: A total of 52 patients with ESUS were examined by TEE and cTTE. The detection rate of patent foramen ovale (PFO) and right-to-left shunt (RLS) grade were compared in patients with ESUS between cTTE alone and cTTE combined with TEE. The Risk of Paradoxical Embolism (RoPE) score, PFO diameter, and PFO length of patients with PFO-associated ESUS and non-PFO-associated ESUS were compared by cTTE alone and cTTE combined with TEE. The receiver operating characteristic (ROC) curve was utilized to determine the effect of RoPE score and PFO diameter on patients with PFO-associated ESUS. RESULTS: The positive rate of PFO detected by cTTE alone (46.15%) was lower than that detected by cTTE combined with TEE (69.23%). The proportion of patients with RLS grade I + II + III detected by cTTE combined with TEE (69.23%) was higher than that detected by cTTE alone (46.15%). Both the RoPE score and PFO diameter were significantly greater in the patients with PFO-associated ESUS than in the patients with non-PFO-associated ESUS (p < .05). The combination of RoPE score and PFO diameter had the largest area under the ROC curve (AUC = 0.875), which was larger than the AUC alone of RoPE score (AUC = 0.819) and PFO diameter (AUC = 0.783) (p < .05). CONCLUSION: The combination of cTTE and TEE is helpful to the diagnosis of ESUS patients caused by PFO and to judge the degree of RLS.
RESUMO
RLS can be diagnosed using US, CT angiography, and right heart catheterization. However, most reliable diagnostic modality remains undetermined. c-TCD was more sensitive than c-TTE in the diagnosis of RLS. This was true especially for the detection of provoked shunts or mild shunts. c-TCD can be used as the preferred screening method for RLS.
Assuntos
Ecocardiografia Transesofagiana , Forame Oval Patente , Humanos , Forame Oval Patente/diagnóstico por imagem , Ecocardiografia/métodos , Ultrassonografia Doppler Transcraniana , Meios de ContrasteRESUMO
The aim of this research was to compare the sensitivity and positive predictive value of contrast transcranial Doppler (c-TCD), contrast transthoracic echocardiography (c-TTE), and contrast transesophageal echocardiography (c-TEE), to determine the best method for diagnosing patent foramen ovale (PFO) and to provide a reference for the further improvement of clinical practice. We investigated 161 patients who suffered from migraines, cryptogenic stroke, TIA, and cerebral infarction of unknown cause. All patients underwent transcatheter examination, and the results of the right heart catheterization (RHC) were considered the gold standard for PFO diagnosis. The present study revealed that c-TTE with the Valsalva maneuver had a higher sensitivity in detecting PFO related right-to-left shunt (PFO-RLS), c-TCD performed similarly to c-TEE but maybe produce more false positives. Moreover, when we observed color shunt from the slit-like channel between the septum primum and the septum secundum on TEE, the positive predictive value was the highest. Patients with suspected PFO should be examined with c-TTE and c-TEE for confirmation. When there were a large number of bubbles in the left heart, especially in the presence of color shunt, the positive predictive value was the highest. The positive results of c-TCD only point out the presence of right-to-left shunt and cannot exclude extracardiac shunt, so c-TCD should not be used as a screen for PFO, additional measures such as c-TTE and c-TEE should be used.
Assuntos
Forame Oval Patente , Meios de Contraste , Ecocardiografia , Ecocardiografia Transesofagiana , Forame Oval Patente/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Ultrassonografia Doppler TranscranianaRESUMO
Objective: The purpose of this study was to explore the different provocative maneuvers in detecting right-to-left shunt during contrast transthoracic echocardiography (cTTE). Methods: We evaluated 378 patients for right-to-left shunt detection by cTTE at the quiet respiration, during Valsalva maneuver (blowing into a face mask connected to a sphygmomanometer at 40 mmHg for 10 s), and during cough maneuver, performed in random order, and the degree of right-to-left shunt as the number of microbubbles in the left atrium per frame after each provocative maneuver was recorded. Results: The detection rates of right-to-left shunt for quiet respiration, Valsalva maneuver, and cough maneuver were 16%, 33%, and 38%, respectively (p < .001). The detection rate for cough maneuver was significantly higher than that for Valsalva maneuver (p < .001). There was no significant difference between Valsalva maneuver and cough maneuver in terms of detecting moderate- or severe-extent right-to-left shunt (p > .05), but cough maneuver was significantly better than Valsalva maneuver at detecting mild-extent right-to-left shunt (p = .001). Conclusions: Cough maneuver is an effective alternative to Valsalva maneuver, with a higher detection rate for mild-extent right-to-left shunt during cTTE, maybe due to its own mechanical characteristics.
Assuntos
Tosse , Ecocardiografia , Forame Oval Patente/diagnóstico por imagem , Hemodinâmica , Manobra de Valsalva , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/fisiopatologia , Humanos , Masculino , Microbolhas , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Adulto JovemRESUMO
AIM: To explore the value of cough maneuver (CM) in detecting right-to-left (RLS) during contrast transthoracic echocardiography (cTTE) and its mechanism. METHOD: We enrolled 196 patients with a high level of clinical suspicion of RLS underwent cTTE for RLS detection. Valsalva maneuver (VM) (blowing into a face mask connected to a sphygmomanometer at 40 mm Hg for 10 seconds) and CM were performed to provoke RLS, respectively. A comparison of the two provocative maneuvers in terms of the RLS-detection rate, the degree of RLS, the mobility of septum primum was done. RESULTS: The detection rates of RLS for CM were significantly higher than that for VM (38.3% vs 32.1%), (P < 0.001). There was no significant difference between VM and CM in terms of detecting moderate- or severe-extent RLS (P > 0.05), however, CM was significantly better than VM in detecting mild-extent RLS (P = 0.004). CM caused a greater mobility of septum primum than VM (20.1 ± 0.2 mm vs 6.3 ± 0.1 mm), (P < 0.001). CONCLUSION: Cough maneuver had a higher detection rate for RLS than VM during cTTE, maybe due to its greater mobility of septum primum than VM caused.
Assuntos
Meios de Contraste , Tosse , Ecocardiografia , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/fisiopatologia , Aumento da Imagem/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Adulto JovemRESUMO
Automated recognition of heart shunts using saline contrast transthoracic echocardiography (SC-TTE) has the potential to transform clinical practice, enabling non-experts to assess heart shunt lesions. This study aims to develop a fully automated and scalable analysis pipeline for distinguishing heart shunts, utilizing a deep neural network-based framework. The pipeline consists of three steps: (1) chamber segmentation, (2) ultrasound microbubble localization, and (3) disease classification model establishment. The study's normal control group included 91 patients with intracardiac shunts, 61 patients with extracardiac shunts, and 84 asymptomatic individuals. Participants' SC-TTE images were segmented using the U-Net model to obtain cardiac chambers. The segmentation results were combined with ultrasound microbubble localization to generate multivariate time series data on microbubble counts in each chamber. A classification model was then trained using this data to distinguish between intracardiac and extracardiac shunts. The proposed framework accurately segmented heart chambers (dice coefficient = 0.92 ± 0.1) and localized microbubbles. The disease classification model achieved high accuracy, sensitivity, specificity, F1 score, kappa value, and AUC value for both intracardiac and extracardiac shunts. For intracardiac shunts, accuracy was 0.875 ± 0.008, sensitivity was 0.891 ± 0.002, specificity was 0.865 ± 0.012, F1 score was 0.836 ± 0.011, kappa value was 0.735 ± 0.017, and AUC value was 0.942 ± 0.014. For extracardiac shunts, accuracy was 0.902 ± 0.007, sensitivity was 0.763 ± 0.014, specificity was 0.966 ± 0.008, F1 score was 0.830 ± 0.012, kappa value was 0.762 ± 0.017, and AUC value was 0.916 ± 0.006. The proposed framework utilizing deep neural networks offers a fast, convenient, and accurate method for identifying intracardiac and extracardiac shunts. It aids in shunt recognition and generates valuable quantitative indices, assisting clinicians in diagnosing these conditions.
Assuntos
Ecocardiografia , Redes Neurais de Computação , Humanos , Ecocardiografia/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Microbolhas , Adulto , Meios de Contraste , Interpretação de Imagem Assistida por Computador/métodosRESUMO
BACKGROUND: Cardiac myxomas are the most common type of primary cardiac tumors in adults, but they can have variable features that make them difficult to diagnose. We report two cases of atrial myxoma with calcification or ossification, which are rare pathological subgroups of myxoma. CASE PRESENTATION: A 47-year-old woman and a 35-year-old man presented to our hospital with different symptoms. Both patients had a history of chronic diseases. Transthoracic and transesophageal echocardiography revealed a mass in the left or right atrium, respectively, with strong echogenicity and echogenic shadows. The masses were suspected to be malignant tumors with calcification or ossification. Contrast transthoracic echocardiography(cTEE) showed low blood supply within the lesions. The patients underwent surgical resection of the atrial mass, and the pathology confirmed myxoma with partial ossification or massive calcification. CONCLUSION: We report two rare cases of atrial myxoma with calcification or ossification and analyze their ultrasonographic features. Transthoracic echocardiography and cTEE can provide valuable information for the diagnosis and management of such mass. However, distinguishing calcification and ossification in myxoma from calcification in malignant tumors is challenging. More studies are needed to understand the pathogenesis and imaging characteristics of these myxoma variants.
Assuntos
Calcinose , Átrios do Coração , Neoplasias Cardíacas , Mixoma , Ossificação Heterotópica , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Calcinose/diagnóstico por imagem , Calcinose/diagnóstico , Calcinose/cirurgia , Ecocardiografia , Ecocardiografia Transesofagiana , Átrios do Coração/patologia , Átrios do Coração/diagnóstico por imagem , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/cirurgia , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/patologia , Neoplasias Cardíacas/diagnóstico por imagem , Mixoma/diagnóstico , Mixoma/cirurgia , Mixoma/complicações , Ossificação Heterotópica/diagnóstico , Ossificação Heterotópica/complicações , Ossificação Heterotópica/cirurgiaRESUMO
Purpose: To evaluate and compare the diagnostic value of contrast-enhanced transcranial Doppler (c-TCD) and contrast-enhanced transthoracic echocardiography (c-TTE) for right to left shunt (RLS) in patent foramen ovale (PFO) by meta-analysis. Methods: The literature included in the Cochrane Library, PubMed, and Embase were searched by using "contrast-enhanced transcranial Doppler (c-TCD), contrast-enhanced transthoracic echocardiography (c-TTE), patent foramen ovale (PFO), and right to left shunt (RLS)" as the keywords from inception through April 30, 2024. The diagnostic accuracy research quality assessment tool (QUADAS-2) was used to evaluate the quality of the included literature. The combined sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and Diagnostic odds ratio (DOR) were pooled, and a comprehensive ROC curve analysis was performed. Statistical software StataSE 12.0 and Meta-Disc 1.4 were used for data analysis. Results: A total of 8,536 articles were retrieved, and 9 articles that met all inclusion criteria were included in this meta-analysis. The meta-analysis results show that the combined sensitivity, specificity, PLR, NLR, DOR, and area under the SROC curve of c-TCD for the diagnose of PFO-RLS were 0.91 (95% CI, 0.88-0.93), 0.87 (95% CI: 0.84-0.91), 6.0 (95% CI, 2.78-12.96), 0.10 (95% CI, 0.06-0.18), 91.61 (95% CI, 26.55-316.10), and 0.9681, respectively; the corresponding values of c-TTE were 0.86 (95% CI, 0.84-0.89), 0.88 (95% CI, 0.84-0.91), 5.21 (95% CI, 2.55-10.63), 0.16 (95% CI, 0.09-0.31), 71.43 (95% CI, 22.85-223.23), and 0.9532. The ROC curve shows that c-TCD has slightly higher diagnostic value for PFO than c-TTE, but there is no significant statistical difference (Z = 0.622, p > 0.05). Deek funnel pattern showed no significant publication bias. Conclusion: Both c-TCD and c-TTE have high diagnostic values for PFO-RLS. However, c-TCD has slightly higher sensitivity and lower specificity in diagnosing PFO-RLS compared to c-TTE.Systematic review registration: identifier [CRD42024544169].
RESUMO
OBJECTIVE: This study aims to comprehensively assess the characteristics of patent foramen ovale (PFO) in relation to Cryptogenic Strok (CS) by utilizing transesophageal echocardiography (TEE) and contrast transthoracic echocardiography (c-TTE) and to identify high-risk factors associated with PFO-related CS. BACKGROUND: Transcatheter PFO closure has demonstrated its effectiveness in preventing PFO-related CS. Therefore, understanding the specific structural attributes of PFO associated with CS is imperative. METHODS: Enrollment comprised 113 test patients who experienced CS in conjunction with PFO and 117 control patients diagnosed with migraine with PFO but without a history of stroke. The characteristics of the PFO were observed by TEE and c-TTE. A comparative analysis was undertaken to assess the variations in PFO characteristics between the test patients and controls, and to uncover the independent factors relevant to CS. RESULTS: The patients in the test group were older than the controls. Both the height and length of the PFO during Valsalva exhibited greater dimensions in the test group when contrasted with controls. Notably, the test group presented higher incidence rates of low-angle PFO (defined as an angle between the inferior vena cava (IVC) and PFO ≤ 10°) and atrial septal aneurysm (ASA) as contrasted with the control group. Right-to-left shunt (RLS) III during Valsalva demonstrated a significantly elevated occurrence within the test group as opposed to the controls. Conversely, RLS II during Valsalva exhibited a significantly higher frequency in the controls in contrast to the tests. No significant disparities were observed between the two groups with respect to RLS I during Valsalva and all grades of RLS at rest. Multivariate analysis revealed that the length of the PFO during Valsalva, the presence of ASA, RLS III during Valsalva and low-angle PFO were independent relevant factors associated with CS. CONCLUSIONS: The length of the PFO tunnel, low-angle PFO, RLS III during Valsalva and the presence of ASA were independent risk factors for CS. The combined utilization of TEE and c-TTE may prove valuable in identifying PFO patients at a heightened risk of CS and in facilitating the screening process for transcatheter PFO closure.
.RESUMO
Background: Right-to-left shunt (RLS) is associated with several conditions and causes morbidity. In this study, we aimed to evaluate the effectiveness of synchronous multimode ultrasonography in detecting RLS. Methods: We prospectively enrolled 423 patients with high clinical suspicion of RLS and divided them into the contrast transcranial Doppler (cTCD) group and synchronous multimode ultrasound group, in which both cTCD and contrast transthoracic echocardiography (cTTE) were performed during the same process of contrast-enhanced ultrasound imaging. The simultaneous test results were compared with those of cTCD alone. Results: The positive rates of grade II (22.0%:10.0%) and III (12.7%:10.8%) shunts and the total positive rate (82.1748%) in the synchronous multimode ultrasound group were higher than those in the cTCD alone group. Among patients with RLS grade I in the synchronous multimode ultrasound group, 23 had RLS grade I in cTCD but grade 0 in synchronous cTTE, whereas four had grade I in cTCD but grade 0 in synchronous cTTE. Among patients with RLS grade II in the synchronous multimode ultrasound group, 28 had RLS grade I in cTCD but grade II in synchronous cTTE. Among patients with RLS grade III in the synchronous multimode ultrasound group, four had RLS grade I in cTCD but grade III in synchronous cTTE. Synchronous multimode ultrasound had a sensitivity of 87.5% and specificity of 60.6% in the patent foramen ovale (PFO) diagnosis. Binary logistic regression analyses showed that age (odds ratio [OR] = 1.041) and risk of paradoxical embolism score ≥ 7 (OR = 7.798) were risk factors for stroke recurrence, whereas antiplatelets (OR = 0.590) and PFO closure with antiplatelets (OR = 0.109) were protective factors. Conclusion: Synchronous multimodal ultrasound significantly improves the detection rate and test efficiency, quantifies RLS more accurately, and reduces testing risks and medical costs. We conclude that synchronous multimodal ultrasound has significant potential for clinical applications.
RESUMO
When patent foramen ovale (PFO) combines with the prominent Eustachian valve or Chiari network (EV/CN), contrast transthoracic echocardiography (cTTE) may miss the diagnosis of PFO. We sought to determine the characteristics of right-to-left shunt (RLS) in PFO patients with prominent EV/CN on cTTE and identify the causal factors of missed diagnosis. We consecutively enrolled 98 patients who suffered from PFO-related stroke and with prominent EV/CN. All patients were divided into the delayed and non-delayed groups according to the characteristics of RLS on cTTE. The characteristics of RLS were compared with those of 42 intrapulmonary shunt patients. The anatomical characteristics of PFO and EV/CN were analyzed in the 98 PFO patients. Upon cTTE, significantly delayed occurrence and longer duration of the RLS in the delayed group were found both at rest and during the Valsalva maneuver, similar to the intrapulmonary shunt. Multivariate logistic analysis revealed that the length of EV/CN (>19 mm) and the diameter of PFO at the left atrium aspect (<1.2 mm) were high-risk factors for missed diagnosis. In conclusion, RLS showed delayed emergence and disappearance in some of the PFO patients with prominent EV/CN. The length of EV/CN and the diameter of PFO may have been related to the missed diagnosis of PFO.
RESUMO
PURPOSE: The purpose of this study was to observe the morphologic characteristics of patent foramen ovale (PFO) by transesophageal echocardiography (TEE), and to analyze its correlation with right-to-left shunt (RLS) of contrast-transthoracic echocardiography (c-TTE) and contrast-transcranial Doppler ultrasonography (c-TCD). METHODS: 124 patients with PFO were divided into four groups according to the morphological characteristics of PFO. RLS grade of each group PFO with c-TTE and c-TCD in resting and Valsalva manoeuvre was measured. Anatomical structures influencing RLS grade were analyzed statistically through multivariate logistic analyses and predictive models. RESULTS: The 124 cases of PFO were divided into four groups: 55 cases (44.4%) with smooth uniform tubular tunnel (SUT), 21 cases (16.9%) with granule uniform tubular tunnel (GUT), 23 cases (18.5%) of right funnelform, 25 cases (20.2%) of left funnelform. Between group comparisons and multivariate logistic analyses revealed that PFO morphotype and interatrial septum(IAS) mobility were influencing factors of RLS degree. During Valsalva, the probability of c-TCD RLS ≥ 2 for the right funnelform PFO was 13.428 times that of the GUT, one unit increase in IAS mobility increased the probability of c-TCD RLS ≥ 2 by a factor of 2.029, model predicted c-TCD RLS ≥ 2 with 78.1% sensitivity and 94.7% specificity; During Valsalva, the probability of c-TCD RLS ≥ 2 for the SUT PFO was 4.244 times that of the GUT, one unit increase in IAS mobility increased the probability of c-TTE RLS ≥ 2 by a factor of 2.392, model predicted c-TTE RLS ≥ 2 with 80.2% sensitivity and 87.9% specificity. CONCLUSIONS: Studies have shown that the morphological structure of PFO is an influencing factor of RLS, and TEE can observe the specific morphological characteristics of PFO, which can further predict the level of RLS, help predict the occurrence of Cryptogenic stroke (CS). The above provides more evidences and surgical options for Interventional device closure indications.
Assuntos
Forame Oval Patente , Humanos , Forame Oval Patente/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana , Ecocardiografia , Ecocardiografia TransesofagianaRESUMO
Background: In recent years, increasing attention has been paid to cryptogenic stroke (CS) caused by the patent foramen ovale (PFO). Objective: This study aims to evaluate the value of microbubble transcranial Doppler (MB-TCD) combined with contrast transthoracic echocardiography (cTTE) in the diagnosis of cryptogenic stroke patients with PFO. Materials and Method: From January 2014 to January 2019, patients who suffered from CS were recruited and divided into the cTTE group and MB-TCD combined with cTTE group. All patients were further checked by transesophageal echocardiography (TEE). Results: A total of 130 patients accepted cTTE examination, and 109 patients accepted MB-TCD combined with cTTE. In the group, 52 of the 54 positive patients were finally confirmed by TEE with PFO, and 12 of the 76 negative patients were finally confirmed by TEE with PFO. In combined group, 50 patients were negative on both two examination (Negative group), 54 were positive on both two examination (Positive group) and finally confirmed by TEE indeed with patent foramen ovale (PFO), while remaining five (5) patients were positive only on MB-TCD (Suspected group). After checked by TEE, three (3) of five patients with MB-TCD positive were confirmed by TEE indeed with PFO. The sensitivity, specificity, positive likelihood ratio (+LR), and Youden's index of cTEE in diagnostic of cryptogenic stroke patients with PFO were 81.25%, 96.97%, 26.82 and 0.78, respectively, and these for MB-TCD combined with cTTE were 100%, 96.15%, 25.97 and 0.96, respectively. MB-TCD medium can sensitively discover PFO in cryptogenic stroke patients with 100% sensitivity and a missdiagnosis rate of 0. Conclusion: The combination of MB-TCD and cTTE can improve the sensitivity and specificity of PFO diagnosis in cryptogenic stroke patients. MB-TCD medium also had high sensitivity and specificity.
Assuntos
Forame Oval Patente , AVC Isquêmico , Acidente Vascular Cerebral , Ecocardiografia/efeitos adversos , Ecocardiografia Transesofagiana/efeitos adversos , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Ultrassonografia Doppler Transcraniana/efeitos adversosRESUMO
Background: The association between paroxysmal vertigo and right-to-left shunt (RLS) is rarely reported. This study investigates the prevalence and correlation of RLS in patients with different paroxysmal vertigo diseases. Methods: Patients with paroxysmal vertigo from seven hospitals in China were included in this observational study between 2017 and 2021. Migraine patients within the same period were included for comparison. Demographic data and medical history were collected; contrast transthoracic echocardiography was performed; and the clinical features, Dizziness Handicap Inventory, and incidence of RLS in each group were recorded. Results: A total of 2,751 patients were enrolled. This study's results demonstrated that the proportion of RLS in patients with benign recurrent vertigo (BRV) and vestibular migraine (VM) was significantly higher than that in patients with benign paroxysmal positional vertigo, Meniere's disease, and vestibular paroxysmia (P < 0.05). No statistical difference was shown between the frequency of RLS in patients with BRV and those with migraine and VM. A positive correlation was shown between the RLS grade and Dizziness Handicap Inventory scores of patients with VM and BRV (P < 0.01) after effectively controlleding the effect of confounding variables. Conclusions: RLS was significantly associated with BRV and VM. RLS may be involved in the pathogeneses of BRV and VM and may serve as a differential reference index for the paroxysmal vertigo. Trial Registration: CHRS, NCT04939922, registered 14 June 2021- retrospectively registered, https://register.clinicaltrials.gov.
RESUMO
The association between migraine and patent foramen ovale (PFO) has been documented. We aimed to investigate platelet activation, prothrombotic phenotype, and oxidative stress status of migraineurs with PFO on 100 mg/day aspirin, before and 6 months after PFO closure. Data show that, before PFO closure, expression of the classical platelet activation markers is comparable in patients and aspirin-treated healthy subjects. Conversely, MHA-PFO patients display an increased prothrombotic phenotype (higher tissue factorpos platelets and microvesicles and thrombin-generation potential), sustained by an altered oxidative stress status. This phenotype, which is more controlled by P2Y12-blockade than by aspirin, reverted after PFO closure together with a complete migraine remission. (pLatelEts And MigRaine iN patEnt foRamen Ovale [LEARNER]; NCT03521193).
RESUMO
The purpose of this study was to investigate the impact of the morphologic characteristics of patent foramen ovale (PFO) on right-to-left shunt (RLS) in patients with PFO and cryptogenic stroke using transesophageal echocardiography and saline contrast transthoracic echocardiography (c-TTE). Of the 165 patients with PFO stroke, both the height and the length of PFO in the provoked RLS group were smaller than those in the constant RLS group. PFO height, interatrial septum mobility and proportion of atrial septal aneurysms were greater in the severe RLS group than in the mild and moderate RLS groups. Multivariate analysis revealed that PFO height and interatrial septum mobility were independent predictors of severe RLS. Multiple territorial ischemic lesions were more common in the severe RLS or constant RLS group. Our findings indicated that the severity of RLS was related to the anatomic features in PFO, inducing different cerebral ischemia lesion patterns in cryptogenic stroke patients with PFO.
Assuntos
Ecocardiografia Transesofagiana , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/fisiopatologia , AVC Isquêmico/complicações , Adulto , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo RegionalRESUMO
OBJECTIVE: In recent years, increasing attention has been paid to cryptogenic stroke (CS) caused by the patent foramen ovale (PFO). This study aims to compare contrast transthoracic echocardiography (cTTE) and contrast transcranial Doppler (cTCD) to determine whether cTTE is more suitable and reliable than cTCD for clinical use. METHODS: From March 2017 to May 2018, patients who suffered from migraines, stroke, hypomnesis, or asymptomatic stroke found casually were included in our study. Patients with CS were semirandomly divided into two groups (cTTE and cTCD) according to the date of the outpatient visit. Patients with either of the examination above found positive were selected to finish transesophageal echocardiography (TEE). RESULTS: In our study, the sensitivities of group cTTE positive (group cTTE+) and group cTCD positive (group cTCD+) did not have any statistical difference (89% vs. 80%, p = 0.236). Focusing on group cTCD+, we discovered that the semiquantitative shunt grading was not correlated with whether a PFO was present or not (p = 0.194). However, once the PFO has been diagnosed, the shunt grading was shown to be related to the width of the gaps (p = 0.032, pdeviation = 0.03). CONCLUSION: Both cTTE and the cTCD can be used for preliminary PFO findings. The semiquantitative shunt grading of cTCD and cTTE can suggest the size of the PFO and the next course of treatment. The cTTE may be more significant to a safe PFO (a PFO does not have right-to-left shunts, RLSs). Combining cTTE and TEE could help diagnose PFO and assess CS risk.
Assuntos
Ecocardiografia/métodos , Forame Oval Patente , Acidente Vascular Cerebral , Ultrassonografia Doppler Transcraniana/métodos , Adulto , Doenças Assintomáticas , Meios de Contraste/farmacologia , Correlação de Dados , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Transtornos de Enxaqueca/diagnóstico , Seleção de Pacientes , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologiaRESUMO
AIM: To test the potential association between atrial septal aneurysm (ASA) and migraine in patent foramen ovale (PFO) closure patients through an observational, single-center, case-controlled study. METHODS: We studied a total of 450 migraineurs who had right-to-left shunts and underwent PFO closure in a retrospective single-center non-randomized registry from February 2012 to October 2016 on the condition that they were aged 18-45 years old. Migraine was diagnosed according to the International Classification of Headache Disorders, 3rd edition and evaluated using the Headache Impact Test-6 (HIT-6). All patients underwent preoperative transesophageal echocardiography, contrast transthoracic echocardiography, and computed tomography or magnetic resonance imaging examinations, with subsequent fluoroscopy-guided PFO closure. Based on whether they have ASA or not, the patients were divided into two groups: A (PFO with ASA, n = 80) and B (PFO without ASA, n = 370). Baseline characteristics and procedural and follow-up data were reviewed. RESULTS: Compared to group B, group A had an increased frequency of ischemic lesions (11.3% vs 6.2%, P = 0.038) and migraine with aura (32.5% vs 21.1%, P = 0.040). The PFO size was significantly larger in group A (P = 0.007). There was no significant difference in HIT-6 scores between the two groups before and at the one-year follow-up after the PFO closure [61 (9) vs 63 (9), P = 0.227; 36 (13) vs 36 (10), P = 0.706]. CONCLUSION: Despite its small sample size, our study suggests that the prevalence of ASA in PFO with migraine patients is associated with ischemic stroke, larger PFO size, and migraine with aura.
RESUMO
@#To analyze the clinicial features magnetic resonance imaging manifestations of contrast transthoracic echocardiography(cTTE)on patients cryptogenic stroke,in order to discover the specific clinical characteristics of patients with cTTE+ and contribute to the etiological diagnosis of CS.Methods The clinical and imaging data of 108 patients who were diagnosed with CS in Ningbo Huamei Hospital from August 2020 to May 2022 were retrospectively collected. According to the cTTE results,they were classified intotwo groups:cTTE+ group and cTTEgroup. Then the age of onset,gender,risk factors of cerebrovascular disease(hypertension,diabetes,heart disease,smoking history,drinking history,etc. ),symptoms,NIHSS score,mRS score,left atrium size,infarct types(number,location,size)of cerebral infarction on diffusion weighted imaging(DWI)of the two groups were compared and analyzed.The differences of infarct lesions on DWI with different grades of right-to-left shunt were analyzed.Results(1)The cTTE+ positive rate among 108 ptients with CS was 39.8%,including 30 males(69.8%)and 13 females(30.2%),aged(52.8±17.5)years. Right-to-left shunt was found in 21 patients with grade 1,12 with grade 2,and 10 with grade 3.In the positive group,4 cases of extracardiac shunt were found,and 2 cases of pulmonary arteriovenous fistula were confirmed by operation.(2)Among the two groups of patients,the cTTE+ group had a higher ratio of young adults(P=0.021)and a higher incidence of non-specific symptoms at onset(P=0.008),while the negative group had a higher ratio of core symptoms and personal history of smoking(P=0.012),with statistically significant differences.(3)The proportion of multi-vessel area involved in the cTTE+ group was significantly higher than that in the cTTE-group(P=0.004),Meanwhile,more cerebral infarction lesions were distributed in the vertebrobasilar artery system(P=0.021),Less in the right internal carotid artery system(P=0.045);and the maximum diameter of stroke infarct lesions in the cTTE-group was more distributed in [1cm,3cm],with statistical significance(P<0.05).With the increase of right to left shunt grade,the proportion of lesions<1 cm showed an increasing trend,but there was no significant statistical difference.Conclusion(1)Non-specific symptom onset of CS mainly occurs in multi-vessel distribution areas under 50 years old,and the pathogenesis should be considered to be related to right-to-left shunt.(2)The detection of right-to-left shunt by cTTE is of supplementary value to the etiological diagnosis of CS,which can detect some hidden and undetectable extracardial shunt,suggesting that CS patients should actively undergo cTTE screening,which is helpful to define the etiology and guide the selection of stroke prevention and treatment plan.