Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39189066

RESUMO

BACKGROUND: Redo-transcatheter aortic valve replacement (TAVR) is a promising treatment for transcatheter aortic valve degeneration, becoming increasingly relevant with an aging population. In redo-TAVR, the leaflets of the initial (index) transcatheter aortic valve (TAV) are displaced vertically when the second TAV is implanted, creating a cylindrical cage that can impair coronary cannulation and flow. Preventing coronary obstruction and maintaining coronary access is essential, especially in young and low-risk patients undergoing TAVR. This study aimed to develop a new leaflet modification strategy using laser ablation to prevent coronary obstruction and facilitate coronary access after repeat TAVR. METHODS: To evaluate the feasibility of the leaflet modification technique using laser ablation, the initial phase of this study involved applying a medical-grade ultraviolet laser for ablation through pericardial tissue. Following this intervention, computational fluid dynamics simulations were utilized to assess the efficacy of the resulting perforations in promoting coronary flow. These simulations played a crucial role in understanding the impact of the modifications on blood flow patterns, ensuring these changes would facilitate the restoration of coronary circulation. RESULTS: Laser ablation of pericardium leaflets was successful, demonstrating the feasibility of creating openings in the TAV leaflets. Flow simulation results show that ablation of index valve leaflets can effectively mitigate the flow obstruction caused by sinus sequestration in redo-TAVR, with the extent of restoration dependent on the number and location of the ablated openings. CONCLUSIONS: Laser ablation could be a viable method for leaflet modification in redo-TAVR, serving as a new tool in interventional procedures.

2.
Catheter Cardiovasc Interv ; 102(7): 1401-1405, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37694603

RESUMO

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Desenho de Prótese
3.
Catheter Cardiovasc Interv ; 98(6): E847-E854, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33960624

RESUMO

AIMS: The aim of this proof-of-concept study was to investigate safety and efficacy of a CT-scan based patient-specific algorithm to maximize coronary clearance and secondarily to achieve anatomically correct commissural alignment with the Acurate Neo device. METHOD AND RESULTS: A total of 45 consecutive patients undergoing TAVR with the Acurate Neo THV were prospectively enrolled in the study. Mean age was 81.6 ± 5.5 years, mean STS score was 6.1 ± 3.7. Device success rate was 100%. Aim of the technique was to rotationally deploy the TAVR device with a commissure lying on the bisector between the coronary ostia as calculated on the pre-procedural CT-scan. At post-TAVR CT-scan, coronary clearance was achieved in 98% of patients with no cases of severe coronary artery overlap. In 42 out of 45 patients, THV was aligned or, at most, mildly misaligned; there were 2 cases of moderate misalignment without any case of severe misalignment. Post-TAVR selective coronary artery engagement was attempted and succeeded in all patients (100%). CONCLUSION: Our CT-scan based patient-specific algorithm is safe and proven to be effective in avoiding coronary artery overlap and providing commissural alignment with Acurate Neo in all treated patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 98(3): 595-604, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33586278

RESUMO

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is an emerging alternative to re-do surgery. However, the challenge of coronary access (CA) following ViV-TAVR is a potential limitation as TAVR expands to younger lower-risk populations. OBJECTIVES: Using post-implantation computed tomography (CT) scans to evaluate the geometrical relationship between coronary ostia and valve frame in patients undergoing ViV-TAVR with the ACURATE neo valve. METHODS: Post-implant CT scans of 18 out of 20 consecutive patients treated with the ACURATE neo valve were analyzed. Coronary ostia location in relation to the highest plane (HP) (highest point of the ACURATE neo or surgical valve) was determined. Ostia located below the highest plan were further subclassified according to the gap available between the transcatheter heart valve frame and ostium (transcatheter-to-coronary [TTC] distance). The impact implantation depth has on these geometrical relationships was evaluated. RESULTS: A total of 21 out of 36 coronary ostia (58%) were located below the level of the HP with the left coronary artery (36%) more likely to be affected than the right (22%). Further sub-classification of these ostia revealed a large (>6 mm), moderate (4-6 mm), and small (<4 mm) TTC distance in 57% (12/21), 38% (8/21), and in 6% (1/18) of cases, respectively. At an implantation depth <4 mm compared to >4 mm, all ostia were located below the HP with no difference in post-procedural mean gradients (14.5 mmHg ± 4.7 vs. 12.6 mmHg ± 5.8; p = .5, 95%CI 3.8-7.5). CONCLUSIONS: CA following ACURATE neo implantation for ViV-TAVR could potentially be challenging in a significant proportion of patients and specific consideration should be given to the implantation depth.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Tomografia , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Herz ; 46(5): 429-436, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34427692

RESUMO

As we approach 20 years of clinical experience with transcatheter aortic valve replacement (TAVR), a vast portfolio of high-quality clinical data has accumulated, confirming the safety and efficacy of TAVR across the entire spectrum of surgical risk. Although many aspects of this innovative therapy have been thoroughly studied, several challenges remain. As TAVR is expanding to include younger low-risk patients, with longer life expectancy, one major unsolved issue is represented by transcatheter heart valve (THV) durability, since robust THV durability data are currently limited to approximately 5-6 years. Additionally, steric interactions between THV components and coronary ostia may render coronary access particularly difficult, and thus personalized decisions regarding THV type and implanting techniques are of paramount importance to secure future coronary access. Since bicuspid aortic valve (BAV) stenosis may be associated with unfavorable anatomic factors, it has represented an exclusion criterion in major randomized TAVR trials. Albeit promising data are available from multicenter registries, results of specifically designed randomized trials are eagerly needed to inform use of TAVR for BAV stenosis. Although valve-in-valve (ViV) TAVR has emerged as an effective treatment option for degenerated aortic bioprostheses, ViV procedures are associated with specific risks, which mandated the development of specific techniques aimed at reducing the occurrence of periprocedural adverse events. Despite the transfemoral approach represents the access of choice for TAVR, a significant proportion of patients have significant peripheral artery disease and alternative vascular access routes have been increasingly evaluated with encouraging data regarding their safety and feasibility.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Multicêntricos como Assunto , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 96(5): E535-E541, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31912968

RESUMO

BACKGROUND: Incidence of coronary access (CA) after transcatheter aortic valve replacement (TAVR) at long-term follow-up remains unknown. CA and percutaneous coronary intervention (PCI) after TAVR might present technical challenges, particularly with supra-annular devices. METHODS: Patients undergoing CA after being treated with TAVR at our institution were included in the study. Coronary interventions for coronary obstruction during TAVR procedure were excluded. Incidence, feasibility and outcomes of CA after TAVR were analyzed. RESULTS: Out of 912 patients aged 80 ± 7 years treated with TAVR at our institution between 2007 and 2018, 48 (5.3%) underwent CA at a median follow up of 769 [363-1,471] days. Twenty-one had received a SAPIEN XT, 15 a SAPIEN 3, 6 Corevalve, 2 Evolut Pro, 2 JenaValve, and 2 Lotus valve. PCI was indicated in 26 (54%) cases. Seventeen (35%) procedures were performed for acute coronary syndromes (ACS). Independent predictors of CA after TAVR were younger age, previous PCI, and CABG. CA of both vessels was feasible in all patients with an intra-annular device, while the right coronary artery was not engaged in two patients with a supra-annular valve. PCI was successful in all but one case. All-cause mortality was similar between patients needing CA for ACS and those who had other clinical indications. CONCLUSIONS: In this high-risk AS population, incidence of CA after TAVR at long-term follow-up was rather low. CA and PCI were safe and successful in most cases, with a lower rate of selective CA for supra-annular devices.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Angiografia Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/terapia , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Angiografia Coronária/efeitos adversos , Angiografia Coronária/mortalidade , Estenose Coronária/mortalidade , Estudos de Viabilidade , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
9.
Can J Cardiol ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39179204

RESUMO

BACKGROUND: Coronary access (CA) and percutaneous coronary intervention (PCI) might be challenging after valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) with supra-annular self-expanding valves (SS-TAVs) in surgical aortic valves (SAVs). Our study aim was to compare feasibility, predictors and techniques of CA and PCI following ViV-TAVR with ACURATE neo2 (Boston Scientific, Marlborough) and Evolut PRO+ (Medtronic, Minneapolis, Minnesota). METHODS: Fifteen computed tomography (CT)-based patient-specific aortic models were 3D-printed and implanted with specific SAVs and with the two SS-TAVs with commissural alignment. Two operators attempted CA (n=120) and PCI (n=120) of each coronary artery in a pulsatile-flow-simulator, under real catheterization laboratory conditions. The primary endpoints were the rate of successful CA and PCI. Outcomes with different SS-TAVs were directly compared. An internally mounted borescope camera was utilized to assess procedures. CT of the models was obtained. RESULTS: ACURATE neo2 showed significantly higher rates of successful CA (96.7%vs.75%, p=0.001) and PCI (98.3%vs.85%, p=0.008), and was associated with a shorter procedural time as compared to Evolut PRO+. Independent predictors of unsuccessful CA and PCI were smaller SAV size and Evolut PRO+. The advantage of ACURATE neo2 was mediated by a larger valve-to-anatomy distance at the top of the leaflet plane (11.3vs.4.8 mm), facilitating more often an external cannulation approach for both CA (36.7%vs.15%, p<0.001) and PCI (36.7%vs.21.7%, p=0.013). CONCLUSIONS: The rate of successful CA and PCI following ViV-TAVR was higher with ACURATE neo2 as compared to Evolut PRO+. The differences in SS-TAVs design impacted the cannulation approach and subsequent procedural outcomes.

10.
Int J Cardiol ; 395: 131572, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37913960

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) showed safety and efficacy in patients with severe aortic stenosis. Commissural alignment (CA) during TAVR has the potential to reduce the impact of the prostheses on accessibility of coronary arteries, as misalignment of the neocommissures could cause partial overlap with coronary ostia. Therefore, the aim of this study was to investigate the impact of CA on coronary overlap rates. METHODS: We examined the techniques of CA and their impact on coronary access. Eligible studies were searched for on Pubmed, SCOPUS and DOAJ and selected using PRISMA guidelines. The primary endpoint was the incidence of a severe coronary overlap or failed coronary re-access. Results of the analysis are expressed as Risk Ratio (RR) with 95% CI. RESULTS: Four studies were included in this analysis. In these, 681 patients underwent TAVR with CA and 210 underwent TAVR without CA. We examined Evolut valves and Acurate Neo valves. The primary endpoint occurred in 138 patients undergoing TAVR with CA and in 154 patients without CA (RR = 0.279; 95% CI 0.201-0.386; p < 0.001). Neither prosthesis-related, nor patient-related factors had a significant interaction with the measured effect. CONCLUSIONS: Commissural alignment was associated with significantly lower rates of commissure-to-coronary ostia overlap and failure of coronary access. Consequently, a modified insertion technique could reduce coronary overlap and coronary occlusion, particularly in supra-annular valves. Therefore, controlled orientation of prostheses by CA during TAVR could favour coronary access, especially in younger patients that could require coronary re-access after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Fatores de Risco
11.
Artigo em Inglês | MEDLINE | ID: mdl-38677895

RESUMO

BACKGROUND: Radial artery access has been used for left heart catheterization (LHC) and percutaneous coronary intervention (PCI) for over 30 years. This method has gained popularity among operators due to superficial vessel anatomy, allowing for easy accessibility and compressibility, resulting in effective hemostasis. METHODS: We conducted a retrospective analysis of patients who underwent PCI due to ST-elevation myocardial infarction (STEMI), non-ST-elevation acute coronary syndrome (NSTE-ACS), and chest pain (stable angina) from November 2013 to February 2023. RESULTS: We analyzed validated registries and found 7714 PCIs. Of these, 1230 were STEMI patients, 5585 were NSTE-ACS patients, and 899 were stable angina patients, forming the basis of our final analysis. In STEMI patients, there was a trend toward a higher rate of ventriculography with femoral access compared to radial access (53.4 % vs. 47.5 %, p = 0.06), which was also observed in NSTE-ACS patients (34.2 % vs. 31.8 %, p = 0.07). The use of central venous access was more common with femoral access in all three diagnoses, with significantly higher rates seen in STEMI patients (36.2 % vs. 7.6 %, p < 0.001), NSTE-ACS patients (19.3 % vs. 2.8 %, p < 0.001), and chest pain patients (26.4 % vs. 2.7 %, p < 0.001). CONCLUSIONS: The analysis revealed that operators may perform fewer ventriculography and RHC procedures when using radial access as compared to femoral access. While there is discrepancy in performing left ventriculography and RHC when using a radial artery, it is essential to emphasize that routinely performing ventriculography and hemodynamic assessment has not proven to impact outcomes, despite their contributions to proper decision-making and treatment.

12.
Int J Cardiovasc Imaging ; 40(7): 1555-1564, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38795237

RESUMO

Transcatheter aortic valve implantation (TAVI) with commissural alignment aims to limit the risk of coronary occlusion and maintain good coronary access. However, due to coronary origin eccentricity within the coronary cusp, coronary-commissural overlap (CCO) may still occur. TAVI using coronary alignment, rather than commissural alignment, may further improve coronary access. To compare rates of CCO after TAVI using commissural versus coronary alignment methodology. Cardiac CT scans from 102 patients with severe (tricuspid) aortic stenosis referred for TAVI were analysed. Native cusp asymmetry and coronary eccentricity were defined and used to simulate TAVI using commissural versus coronary alignment. Rates of optimal coronary alignment (< 10° from cusp centre) and severe misalignment (< 15° from coronary-commissural overlap) were compared. Additionally, the impact of valve misalignment during implantation was assessed. The native right coronary artery (RCA) origin was 15.8° (9.5 to 24°) closer to the right coronary cusp/non-coronary cusp (RCC-NCC) commissure than the centre of the right coronary cusp. The native left coronary artery (LCA) origin was 4.5° (0 to 11.5°) closer to the left coronary cusp/non-coronary cusp (LCC-NCC) commissure than the centre of the left coronary cusp (p < 0.01). Compared to commissural alignment, coronary alignment doubled the proportion of optimally-aligned RCAs (62/102 [60.8%] vs. 31/102 [30.4%]; p < 0.001), without a significant change in optimal LCA alignment (62/102 [60.8% vs. 74/102 [72.6%]; p = 0.07). There were no cases of severe misalignment with either strategy. Simulating 15° of valve misalignment resulted in severe RCA compromise risk in 7/102 (6.9%) of commissural alignment cases, compared to none using coronary alignment. Fluoroscopic projection was similar with both approaches. Coronary alignment resulted in a 2-fold increase of optimal TAVI positioning relative to the RCA ostium when compared to commissural alignment without impacting the LCA. Use of coronary alignment rather than commissural alignment may improve coronary access after TAVI and is less sensitive to valve rotational error, particularly for the right coronary artery.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Oclusão Coronária , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Masculino , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Feminino , Idoso , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/fisiopatologia , Oclusão Coronária/terapia , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estudos Retrospectivos , Medição de Risco , Valor Preditivo dos Testes , Vasos Coronários/diagnóstico por imagem , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores
13.
Front Cardiovasc Med ; 10: 1154556, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37153454

RESUMO

Transcatheter aortic valve replacement (TAVR) indications recently extended to lower surgical risk patients with longer life expectancy. Commissural alignment (CA) is one of the emerging concepts and is becoming one of the cornerstones of the TAVR procedure in a patient with increased longevity. Indeed, CA may improve transcatheter heart valve (THV) hemodynamics, future coronary access, and repeatability. The definition of CA has been recently standardized by the ALIGN-TAVR consortium using a four-tier scale based on CT analysis. Progress has been made during the index TAVR procedure to optimize CA, especially with self-expandable platforms. Indeed, specific delivery catheter orientation, THV rotation, and computed-tomography-derived views have been proposed to achieve a reasonable degree of CA. Recent data demonstrate feasibility, safety, and a significant reduction in coronary overlap using these techniques, especially with self-expandable platforms. This review provides an overview of THV CA including assessment methods, alignment techniques during the index TAVR procedure with different THV platforms, the clinical impact of commissural misalignment, and challenging situations for CA.

14.
Cardiovasc Interv Ther ; 38(3): 275-286, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36943655

RESUMO

Latest clinical trials have indicated favorable outcomes following transcatheter aortic valve replacement (TAVR) in low surgical risk patients with severe aortic stenosis. However, there are unanswered questions particularly in younger patients with longer life expectancy. While current evidence are limited to short duration of clinical follow-up, there are certain factors which may impair patients clinical outcomes and quality-of-life at long-term. Contemporary issues in the current TAVR era include prosthesis-patient mismatch, heart failure hospitalization, subclinical thrombosis, future coronary access, and valve durability. In this review, the authors review available evidence and discuss each remaining issues and theoretical treatment strategies in lifetime management of TAVR patients.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
15.
J Clin Med ; 12(14)2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37510906

RESUMO

Within the last two decades, transcatheter aortic valve replacement (TAVR) has transformed the treatment strategy for symptomatic severe aortic stenosis (AS), representing a less invasive alternative to traditional open-chest surgery. With time, advances in device features, imaging planning, and implantation techniques have contributed to an improvement in safety as well as a reduction in procedural complications. This has led to the expansion of TAVR to lower-risk patients, where TAVR has shown favorable outcomes compared to surgical aortic valve replacement (SAVR). As TAVR expands to younger and lower-risk patients with longer life expectancies, the need for reintervention for failing transcatheter heart valves is expected to increase. Redo-TAVR has gained increasing relevance in the lifetime management of AS as one of the treatment strategies available for structural valve dysfunction (SVD). However, some issues are associated with this approach, including coronary re-access and the risk of coronary obstruction. In this review, we provide essential concepts to properly select candidates for Redo-TAVR, updated data on clinical outcomes and complication rates, and current gaps in evidence.

16.
J Clin Med ; 12(6)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36983139

RESUMO

Transcatheter aortic valve implantation (TAVR) is the first therapeutic option for elderly patients with severe symptomatic aortic stenosis, and indications are steadily expanding to younger patients and subjects with lower surgical risk and longer life expectancy. Commissural alignment between native and transcatheter valves facilitates coronary access after TAVR and is thus considered a procedural goal, allowing long-term management of coronary artery disease. Moreover, commissural alignment may potentially have a positive impact on transvalvular hemodynamic and valve durability. This review focus on technical hints to achieve commissural alignment and current evidence for different transcatheter aortic valves.

17.
JACC Cardiovasc Interv ; 16(10): 1192-1204, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37225290

RESUMO

BACKGROUND: Data regarding the impact of high transcatheter heart valve (THV) implantation on coronary access after transcatheter aortic valve replacement (TAVR) as assessed by postimplantation computed tomography (CT) are scarce. OBJECTIVES: The authors sought to assess the impact of high THV implantation on coronary access after TAVR. METHODS: We included 160 and 258 patients treated with Evolut R/PRO/PRO+ and SAPIEN 3 THVs, respectively. In the Evolut R/PRO/PRO+ group, the target implantation depth was 1 to 3 mm using the cusp overlap view with commissural alignment technique for the high implantation technique (HIT), whereas it was 3 to 5 mm using 3-cusp coplanar view for the conventional implantation technique (CIT). In the SAPIEN 3 group, the HIT employed the radiolucent line-guided implantation, whereas the central balloon marker-guided implantation was used for the CIT. Post-TAVR CT was performed to analyze coronary accessibility. RESULTS: HIT reduced the incidence of new conduction disturbances after TAVR for both THVs. In the Evolut R/PRO/PRO+ group, post-TAVR CT showed that the HIT group had a higher incidence of the interference of THV skirt (22.0% vs 9.1%; P = 0.03) and a lower incidence of the interference of THV commissural posts (26.0% vs 42.7%; P = 0.04) with access to 1 or both coronary ostia compared with the CIT group. These incidences were similar between the HIT and CIT groups in the SAPIEN 3 group (THV skirt: 0.9% vs 0.7%; P = 1.00; THV commissural tabs: 15.7% vs 15.3%; P = 0.93). In both THVs, CT-identified risk of sinus sequestration in TAVR-in-TAVR was significantly higher in the HIT group compared with the CIT group (Evolut R/PRO/PRO+ group: 64.0% vs 41.8%; P = 0.009; SAPIEN 3 group: 17.6% vs 5.3%; P = 0.002). CONCLUSIONS: High THV implantation substantially reduced conduction disturbances after TAVR. However, post-TAVR CT revealed that there is a risk for unfavorable future coronary access after TAVR and sinus sequestration in TAVR-in-TAVR. (Impact of High Implantation of Transcatheter Heart Valve during Transcatheter Aortic Valve Replacement on Future Coronary Access; UMIN000048336).


Assuntos
Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tomografia Computadorizada por Raios X
18.
Expert Rev Cardiovasc Ther ; 21(10): 703-712, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37815845

RESUMO

INTRODUCTION: With the expanding indications of transcatheter aortic valve replacement (TAVR) to younger and low-risk patients, the life expectancy of patients currently undergoing TAVR will likely outlive the durability of transcatheter bioprosthesis. Consequently, the number of failed transcatheter bioprosthesis requiring surgical valve explant or redo TAVR is expected to increase. AREAS COVERED: The aim of this review is to provide an updated overview of redo TAVR for treating degenerated transcatheter bioprosthesis, focusing on pre-procedural planning, potential challenges of coronary reaccess during TAVR-in-TAVR and main outcomes of TAVR explant and redo TAVR. EXPERT OPINION: Patient-tailored device selection and individualized implantation height should be carefully assessed during the index TAVR procedure (weighting between pacemaker avoidance and the potential risk of coronary occlusion in future TAVR-in-TAVR). Future prospective studies comparing safety and clinical outcomes between redo TAVR vs TAVR explant are eagerly awaited.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
19.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37988439

RESUMO

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Desenho de Prótese
20.
JACC Cardiovasc Interv ; 15(2): 123-134, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35057982

RESUMO

OBJECTIVES: The aim of this study was to assess cusp symmetry and coronary ostial eccentricity and its impact on coronary access following transcatheter aortic valve replacement (TAVR) using a patient-specific commissural alignment implantation technique. BACKGROUND: TAVR implantation techniques to obtain neocommissural alignment have been introduced. The impact of cusp symmetry and coronary ostial eccentricity on coronary access after TAVR remains unknown. METHODS: Cardiac computed tomographic scans from 200 tricuspid aortic valves (TAVs) and 200 type 1 bicuspid aortic valves (BAVs) were studied. Cusp symmetry and coronary ostial eccentricity were assessed. In addition, the right coronary cusp/left coronary cusp and right coronary artery (RCA)/left coronary artery (LCA) ostia overlap views were calculated and compared. RESULTS: Severe cusp asymmetry (>135°) was more frequent in BAVs (52.5%) than in TAVs (2.5%) (P < 0.001), with the noncoronary cusp being the most common dominant cusp. The RCA ostium was found to be more often eccentric (>20°) than the LCA ostium (28% vs 6%, respectively; P < 0.001). Considering the right/left cusp overlap view, there was <20° deviation between the right coronary cusp-left coronary cusp centered line and the RCA-LCA centered line in 95% of all patients (TAV, 97%; BAV, 93%). The right/left cusp and coronary ostia overlap view differed by <10° and <20° fluoroscopic angulation in 75% and 98% of all cases, respectively. CONCLUSIONS: Using the right/left cusp overlap view to obtain commissural alignment in TAVR is also an effective approach to implant one of the transcatheter heart valve commissures in the near center between both coronary ostia in most TAVs and type 1 BAVs. Preprocedural CT assessment remains crucial to assess cusp symmetry and coronary ostial eccentricity.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa