1.
Sci Justice ; 56(3): 210-215, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27162019

RESUMO

Metal theft in the railroad industry poses significant challenges to transport investigators. Cable sheaths left behind at crime scenes, if appropriately analysed, could provide valuable evidence in a forensic investigation, but attempts at recovering DNA are not routinely made. Experiments were set up to ascertain the success in DNA recovery from the surface of cable sheaths after deposition of (a) sweat, (b) extracted DNA and (c) fingermarks. Since investigators try to collect fingermarks and often treat the cables with cyanoacrylate fuming (CNA fuming) or wet powder suspensions (WPS) to enhance the marks this study investigated the recovery of DNA from fingermarks pre- and post-enhancement. The double-swab technique and mini-taping were compared as options to recover DNA from the cable sheaths. Results demonstrate that generally, there is no significant difference between using swabs or mini-tapes to recover the DNA from the non-porous cables (p>0.05). It was also illustrated that CNA fuming performed better than WPS in terms of subsequent recovery and profiling of DNA. CNA fuming resulted in an average increase in DNA recovered via swabbing and taping (more than 4× and 8×, respectively), as compared to no treatment, with 50% of the DNA recovered after CNA fuming generating full DNA profiles.


Assuntos
Impressões Digitais de DNA , DNA/isolamento & purificação , Dermatoglifia , Suor/química , Tato , Cianoacrilatos , Humanos , Ferrovias , Roubo , Volatilização
2.
Sci Justice ; 54(2): 133-40, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24630323

RESUMO

Both vacuum metal deposition (VMD) and cyanoacrylate fuming (CAF) are techniques used to visualise latent fingermarks on smooth non-porous surfaces such as plastic and glass. VMD was initially investigated in the 1970s as to its effectiveness for visualising prints on fabrics, but was abandoned when radioactive sulphur dioxide was found to be more effective. However, interest in VMD was resurrected in the 1990s when CAF was also used routinely. We now report on studies to determine whether VMD or CAF is the more effective technique for the detection of marks on fabrics. Four different fabrics, nylon, polyester, polycotton and cotton, were utilised during this study, along with 15 donors who ranged in their age and ability to leave fingermarks, from good to medium to poor, thus reflecting the general population. Once samples were collected they were kept for a determined time (1, 2, 3, 4, 5, 6, 7, 14, 21 or 28 days) and then treated using either the gold and zinc metal VMD process or standard cyanoacrylate fuming. The smoother fabrics, such as nylon, consistently produced greater ridge detail whereas duller fabrics, like cotton tended only to show empty prints and impressions of where the fabric had been touched, rather than any ridge details. The majority of fabrics did however allow the development of touch marks that could be targeted for DNA taping which potentially could lead to a DNA profile. Of the two techniques VMD was around 5 times more effective than CAF, producing a greater amount of ridge detail, palmar flexion creases and target areas on more samples and fabrics.


Assuntos
Cianoacrilatos , Dermatoglifia , Volatilização , Fibra de Algodão , Humanos , Nylons , Poliésteres , Vácuo
3.
J Forensic Sci ; 69(5): 1706-1717, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38940006

RESUMO

DNA typing of latent fingerprints is highly desirable to increase chances of individualization. We recovered DNA from Cyanoacrylate (CA) fumed fingerprints and used both GlobalFiler™ and ForenSeq™ DNA Signature Prep kits for DNA typing. For GlobalFiler™, samples were processed using a protocol modified for Low Template (LT)-DNA samples (half-volume reactions, 30 cycles) while for ForenSeq™ DNA Signature Prep, samples were processed using a standard protocol and fluorometer-based library quantitation. We evaluated genotyping success and quality of profiles in terms of completeness, Peak Height Ratio/Allele Coverage Ratio, presence of PCR artifacts and drop-in alleles. With GlobalFiler™, average autosomal STR (aSTR) profile completeness was 44.4% with 2-20 pg, 54.3% with 22-60 pg, and 95% with 64-250 pg DNA input. CODIS uploadable profiles were obtained in 2/10, 3/11, and 11/12 samples in these ranges. With ForenSeq™ DNA Signature Prep, average aSTR profile completeness was 19.7% with 1-20 pg and 45.2% with 22-47 pg but increased to 78.3% with 68-122 pg and 86.7% with 618-1000 pg DNA input. Uploadable profiles were obtained in 0/12, 4/11, 4/7, and 3/3 samples for these ranges. Results show very high sensitivity using both kits. Half-volume reactions and 30 cycles had minimal negative effect on Globalfiler™ profile quality, providing support for wider use after validation experiments to routinely improve results from LT samples. A standard protocol for the ForenSeq™ DNA Signature Prep kit was also highly successful with LT DNA obtained from CA-fumed fingerprints with additional information from isometric STR alleles and other markers.


Assuntos
Cianoacrilatos , Impressões Digitais de DNA , Dermatoglifia , Repetições de Microssatélites , Reação em Cadeia da Polimerase , Humanos , Impressões Digitais de DNA/métodos , Genótipo , Alelos , DNA/isolamento & purificação , Sequenciamento de Nucleotídeos em Larga Escala , Análise de Sequência de DNA
4.
J Forensic Sci ; 58(2): 508-12, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23316682

RESUMO

We have carried out experiments to investigate the aging of latent fingerprints deposited on black PVC over a period of 4-15 weeks. A thumbprint was used in each case and before deposition of the print the donor rubbed their thumb around their nose to add sebaceous deposits. We have studied the effect of heat, light, and moisture and we find that moisture is the most significant factor in the degradation of the latent print. We have attempted to enhance these latent prints by dusting with valine powder or powders composed of valine mixed with gold or red fluorescent commercial fingerprint powders. To make a direct comparison between "treated" and "untreated" prints, the prints were cut in half with one-half being "treated" and one-half not. Our studies show the best results being obtained when powders of valine and red fluorescent powders are applied prior to cyanoacrylate fuming.

5.
J Forensic Sci ; 66(3): 1085-1093, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33547641

RESUMO

Development of latent prints employing cyanoacrylate ester (CA) can be a multistep process including CA fuming and subsequent fluorescent staining to produce fingerprints of sufficient contrast for comparison work. To enable a single-step CA fuming-staining process, a selection of fluorophores have been developed as sublimation dyes in CA fuming. A greater array of such luminescent sublimation dyes would allow users greater flexibility in selecting a particular dye-CA combination to best suit their processing needs. Toward this end, six benzoic acid derivatives were evaluated for use as luminescent sublimation dyes under elementary CA fuming conditions using a single non-porous surface type and an inexpensive handheld UV lamp for excitation. Two benzoic acid derivatives, 2-hydroxybenzoic acid (salicylic acid) and 2-aminobenzoic acid (anthranilic acid), were identified as new potential luminescent sublimation dyes with stained fingerprints excited at 254 nm. The fluorescence intensity and stability of prints produced via the sublimation of CA with 2-hydroxybenzoic acid and 2-aminobenzoic acid were evaluated over approximately six weeks using image and statistical analysis.

6.
J Forensic Sci ; 65(5): 1465-1473, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32543741

RESUMO

Banknotes are often found in high-profile crimes such as armed robberies, bribery, and terrorist activity. However, such exhibits present a challenge to forensic operatives regarding fingermarks development, due to their mass quantities, potential for fingermarks on both sides, and their unique complex background in terms of color, irregular patterns, and topography. Hence, the standard development protocols become inefficient, due to the difficulty in achieving high contrast images over the background. This study focused on finding an operational sequence that would minimize the time of work on polymer banknotes, in terms of both development and image processing. Thirty-two fingermarks were developed by vacuum metal deposition (VMD), black magnetic powder, and cyanoacrylate fuming (CA) followed by visualization and imaging by reflected short-wave UV (RUVIS) (96 in total), showing a distinct advantage to the CA and RUVIS imaging over the other two techniques with a 75% success rate in the dark and high background regions, due to its physical principle which neutralizes high background interference. The images were then scanned by the automatic fingerprint identification system (AFIS) to test its ability to correctly differentiate false background features from real ones, again, showing a superiority of the RUVIS with 63% of the total initial marked features, being real. Overall, the CA and RUVIS sequence was found to be an ultimate method for multiple, same-type surfaces, with the RUVIS capable of visualization and capturing of the images simultaneously, significantly reducing the time of development and image processing.

7.
Sci Justice ; 59(5): 486-497, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31472793

RESUMO

This study consisted of three parts to evaluate the performance of Lumicyano™ on a variety of fabrics. One part assessed the impact of dye percentage (8%, 9% and 10%) on visualisation of fingermark detail and luminescent brightness in split grab marks. A 9% dye produced the highest quality detail of grab impressions with least interference from background fluorescence. The second part investigated the optimal relative humidity (RH, 75-84%) for certain fabric types using Lumicyano on split, six-series depletion fingermarks. It was concluded that the recommended RH of 80% remained the ideal cyanoacrylate fuming environment. The final and third part of this study determined the impact of sequential addition of Basic Yellow 40 (BY40) on Lumicyano compared to traditional cyanoacrylate (CA) followed with BY40 application. Results from this study demonstrated that Lumicyano on its own developed fingermarks with superior quality to Lumicyano with sequential addition of BY40 or traditional cyanoacrylate followed by BY40. Inclusion of more fabrics, donors and longer ageing periods should be explored in future studies to determine what frameworks are best for certain types of fabrics.

8.
Forensic Sci Int ; 300: e9-e12, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31078350

RESUMO

Cyanoacrylate fuming, rhodamine 6G staining and 532 nm laser light visualization were used to reveal a thirty-year-old fingermark on a plastic bag discovered at a double homicide scene.

9.
J Mass Spectrom ; 54(3): 222-226, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30600868

RESUMO

Despite cyanoacrylate fuming being widely used in the forensic science field, its mechanism is not well understood. In this study, matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is used to study latent fingerprints that have been cyanoacrylate fumed in an attempt to gain insight into the fuming mechanism. In the negative mode mass spectrometry data, four compounds related to the polymerization of cyanoacrylate are identified and their structures are determined from accurate mass and MS/MS. A mechanism is proposed for the formation of these compounds that are regarded as intermediates in the polymerization reaction. In addition, based on the fuming of standard endogenous compounds, we suggest that fatty acids and amino acids are the major catalytic nucleophiles that initiate the polymerization reactions.

10.
J Forensic Sci ; 63(6): 1854-1857, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29570775

RESUMO

For new techniques to be incorporated into forensic science, they must be compatible with current practices. Here, cyanoacrylate fuming, a common development technique for latent fingerprints, is studied for its compatibility with matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for chemical imaging of latent fingerprints. Half of a fingerprint was fumed while the other half was not; then, the changes in chemical composition and signal intensity were compared with MALDI-MS imaging. No evidence was found that fingerprint compounds are chemically altered by fuming or their signal intensities affected. The only exceptions were significant signal loss for quaternary ammonium compounds from hygiene products and moderate signal loss for tertiary amine compounds. This result is in striking contrast with the previous attempts by others, which is attributed to the difference in instrumentation.

11.
Egypt J Forensic Sci ; 7(1): 4, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28781896

RESUMO

Cyanoacrylate, also called super glue, fuming is a chemical method for the detection of latent fingermarks on non-porous surfaces such as glass, plastic etc. The method relies on the deposition of polymerized cyanoacrylate ester on residues of latent fingermarks. The method develops clear, stable, white colored fingerprints. However, several post-treatement procedures can be used to improve the contrast of developed prints. In addition to it, some pre-treatment procedures can also be used to develop aged latent fingermarks. It is an efficient, non-destrcutive and excellent procedure for developing latent fingermarks.

12.
J Forensic Sci ; 61(4): 1100-6, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27364294

RESUMO

A method has been developed for the visualization of latent fingerprints on fabrics, which is based upon cyanoacrylate (superglue) fuming followed by imaging using an infrared microscope. Results show that imaging on smooth, shiny fabrics such as polyester, silk, nylon, and acetate of different colors and patterns can give an improvement over existing enhancement methods. Results for cotton and polycotton were less successful and it is thought this may be due a combination of the presence of the carbonyl functional group in these fabrics as well as their absorbency to fingerprint sweat. The carbonyl peak (1700 cm(-1) ) provided the optimum spectroscopic feature to map and image a fingerprint. Comparisons between infrared mapping at a specific frequency range and principal component analysis showed that improved imaging was obtained with principal component analysis.

13.
J Forensic Sci ; 61(3): 787-91, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27122421

RESUMO

One of the crucial factors determining the cyanoacrylate deposit quality over latent fingerprints appeared to be the extent of the humidity. This work focuses on the enhancement/refreshment of age-degraded latent fingerprints by irradiating the samples with UV, X-ray, or thermal neutrons prior to the cyanoacrylate (CA) fuming. Age degradation of latent fingerprints deposited on glass surfaces was examined through the decrease in the number of characteristic minutiae counts over time. A term "critical day" was introduced for the time at which the average number of identifiable minutiae definitions drops to one-half. Fingerprints older than their "critical day" were exposed to either UV, X-ray, or thermal neutrons. Identical reference samples were kept unexposed. All samples, both reference and irradiated, were developed during a single CA fuming procedure. Comparative latent fingerprint analysis showed that exposure to ionizing radiation enhances the CA fuming, yielding a 20-30% increase in average minutiae count.


Assuntos
Cianoacrilatos , Dermatoglifia , Radiação Ionizante , Humanos , Umidade
14.
J Forensic Sci ; 60(2): 422-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25421356

RESUMO

Physical factors, including the magnitude of the force applied during fingermark deposition, may affect friction ridge surface area and clarity, and the quantity of residue transferred. Consistency between fingermarks may be required; for example, in research projects, yet differences between marks are likely to exist when physical factors are not controlled. Inked fingerprints and latent fingermarks were deposited at 1-10 N at 1 N increments using a variable force fingerprint sampler to control the force, angle of friction ridge and surface contact, and the duration of friction ridge and surface contact. Statistically significant differences existed between the length and width measurements of the inked prints (p ≤ 0.05), particularly at lower forces. Scanning electron microscopy and surface plot analysis demonstrated how differences in force applied during deposition affected ridge surface area, displacement of latent residue, and differences in the quantity of residue transferred. Consistency between inked prints was demonstrated at equivalent forces.

15.
Forensic Sci Int ; 235: 68-77, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24447453

RESUMO

Chemical analysis of latent fingermarks, "touch chemistry," has the potential of providing intelligence or forensically relevant information. Matrix-assisted laser desorption ionization/time-of-flight mass spectrometry (MALDI/TOF MS) was used as an analytical platform for obtaining mass spectra and chemical images of target drugs and explosives in fingermark residues following conventional fingerprint development methods and MALDI matrix processing. There were two main purposes of this research: (1) develop effective laboratory methods for detecting drugs and explosives in fingermark residues and (2) determine the feasibility of detecting drugs and explosives after casual contact with pills, powders, and residues. Further, synthetic latent print reference pads were evaluated as mimics of natural fingermark residue to determine if the pads could be used for method development and quality control. The results suggest that artificial amino acid and sebaceous oil residue pads are not suitable to adequately simulate natural fingermark chemistry for MALDI/TOF MS analysis. However, the pads were useful for designing experiments and setting instrumental parameters. Based on the natural fingermark residue experiments, handling whole or broken pills did not transfer sufficient quantities of drugs to allow for definitive detection. Transferring drugs or explosives in the form of powders and residues was successful for preparing analytes for detection after contact with fingers and deposition of fingermark residue. One downfall to handling powders was that the analyte particles were easily spread beyond the original fingermark during development. Analyte particles were confined in the original fingermark when using transfer residues. The MALDI/TOF MS was able to detect procaine, pseudoephedrine, TNT, and RDX from contact residue under laboratory conditions with the integration of conventional fingerprint development methods and MALDI matrix. MALDI/TOF MS is a nondestructive technique which provides chemical information in both the mass spectra and chemical images.


Assuntos
Dermatoglifia , Substâncias Explosivas/análise , Preparações Farmacêuticas/análise , Aminoácidos/química , Ácidos Cumáricos , Cianoacrilatos , Humanos , Pós , Sebo/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Volatilização
16.
J Forensic Sci ; 59(5): 1368-71, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25182300

RESUMO

We have studied the degradation of sebaceous fingerprints on brass surfaces using silver electroless deposition (SED) as a visualization technique. We have stored fingerprints on brass squares either (i) in a locked dark cupboard or (ii) in glass-filtered natural daylight for periods of 3 h, 24 h, 1 week, 3 weeks, and 6 weeks. We find that fingerprints on brass surfaces degrade much more rapidly when kept in the light than they do under dark conditions with a much higher proportion of high-quality prints found after 3 or 6 weeks of aging when stored in the dark. This process is more marked than for similar fingerprints on black PVC surfaces. Identifiable prints can be achieved on brass surfaces using both SED and cyanoacrylate fuming (CFM). SED is quick and straightforward to perform. CFM is more time-consuming but is versatile and can be applied to a wider range of metal surfaces than SED, for example brass surfaces which have been coated by a lacquer.