Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Eur Radiol ; 2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39060495

RESUMO

OBJECTIVES: The Alberta Stroke Program Early CT Score (ASPECTS), a systematic method for assessing ischemic changes in acute ischemic stroke using non-contrast computed tomography (NCCT), is often interpreted relying on expert experience and can vary between readers. This study aimed to develop a clinically applicable automatic ASPECTS system employing deep learning (DL). METHODS: This study enrolled 1987 NCCT scans that were retrospectively collected from four centers between January 2017 and October 2021. A DL-based system for automated ASPECTS assessment was trained on a development cohort (N = 1767) and validated on an independent test cohort (N = 220). The consensus of experienced physicians was regarded as a reference standard. The validity and reliability of the proposed system were assessed against physicians' readings. A real-world prospective application study with 13,399 patients was used for system validation in clinical contexts. RESULTS: The DL-based system achieved an area under the receiver operating characteristic curve (AUC) of 84.97% and an intraclass correlation coefficient (ICC) of 0.84 for overall-level analysis on the test cohort. The system's diagnostic sensitivity was 94.61% for patients with dichotomized ASPECTS at a threshold of ≥ 6, with substantial agreement (ICC = 0.65) with expert ratings. Combining the system with physicians improved AUC from 67.43 to 89.76%, reducing diagnosis time from 130.6 ± 66.3 s to 33.3 ± 8.3 s (p < 0.001). During the application in clinical contexts, 94.0% (12,591) of scans successfully processed by the system were utilized by clinicians, and 96% of physicians acknowledged significant improvement in work efficiency. CONCLUSION: The proposed DL-based system could accurately and rapidly determine ASPECTS, which might facilitate clinical workflow for early intervention. CLINICAL RELEVANCE STATEMENT: The deep learning-based automated ASPECTS evaluation system can accurately and rapidly determine ASPECTS for early intervention in clinical workflows, reducing processing time for physicians by 74.8%, but still requires validation by physicians when in clinical applications. KEY POINTS: The deep learning-based system for ASPECTS quantification has been shown to be non-inferior to expert-rated ASPECTS. This system improved the consistency of ASPECTS evaluation and reduced processing time to 33.3 seconds per scan. 94.0% of scans successfully processed by the system were utilized by clinicians during the prospective clinical application.

2.
Eur J Nucl Med Mol Imaging ; 50(4): 1228-1239, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36477400

RESUMO

BACKGROUND: Recently, PET/CT imaging with radiolabelled FAP inhibitors (FAPIs) has been widely evaluated in diverse diseases. However, rare report has been published using SPECT/CT, a more available imaging method, with [99mTc]Tc-labelled FAPI. In this study, we evaluated the potential effect of [99mTc]Tc-HFAPi in clinical analysis for digestive system tumours. METHODS: This is a single-centre prospective diagnostic efficiency study (Ethic approved No.: XJTU1AF2021LSK-021 of the First Affiliated Hospital of Xi'an Jiaotong University and ChiCTR2100048093 of the Chinese Clinical Trial Register). Forty patients with suspected or confirmed digestive system tumours underwent [99mTc]Tc-HFAPi SPECT/CT between January and June 2021. For dynamic biodistribution and dosimetry estimation, whole-body planar scintigraphy was performed at 10, 30, 90, 150, and 240 min post-injection in four representative patients. Optimal acquisition time was considered in all the patients at 60-90 min post-injection, then quantified or semi-quantified using SUVmax and T/B ratio was done. The diagnostic performance of [99mTc]Tc-HFAPi was calculated and compared with those of contrast-enhanced CT (ceCT) using McNemar test, and the changes of tumour stage and oncologic management were recorded. RESULTS: Physiological distribution of [99mTc]Tc-HFAPi was observed in the liver, pancreas, gallbladder, and to a lesser extent in the kidneys, spleen and thyroid. Totally, 40 patients with 115 lesions were analysed. The diagnostic sensitivity of [99mTc]Tc-HFAPi for non-operative primary lesions was similar to that of ceCT (94.29% [33/35] vs 100% [35/35], respectively; P = 0.5); in local relapse detection, [99mTc]Tc-HFAPi was successfully detected in 100% (n = 3) of patients. In the diagnosis of suspected metastatic lesions, [99mTc]Tc-HFAPi exhibited higher sensitivity (89.66% [26/29] vs 68.97% [20/29], respectively, P = 0.03) and specificity (97.9% [47/48] vs 85.4% [41/48], respectively, P = 0.03) than ceCT, especially with 100% (24/24) specificity in the diagnosis of liver metastases, resulting in 20.0% (8/40) changes in TNM stage and 15.0% (6/40) changes in oncologic management. CONCLUSION: [99mTc]Tc-HFAPi demonstrates a greater diagnostic efficiency than ceCT in the detection of distant metastasis, especially in identifying liver metastases.


Assuntos
Neoplasias Hepáticas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Sistema Digestório , Recidiva Local de Neoplasia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Prospectivos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único
3.
BMC Gastroenterol ; 23(1): 282, 2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37580680

RESUMO

BACKGROUND: Complications and diagnostic efficiency for liver biopsy are main concerns for clinicians. This study aimed to assess the safety and efficacy of transjugular liver biopsy (TJLB) compared with percutaneous liver biopsy (PLB) when patients had equal level of liver function and number of passes, using propensity score matching (PSM). METHODS: The clinical and pathological data of patients who received TJLB or PLB between January 2012 and October 2022 were collected. Matching factors included age, gender, cirrhosis, portal hypertension, liver function, creatinine, number of passes, hemodialysis, history of anti-coagulation and anti-platelet, and comorbidities. Coagulation indexes were not considered as matching factors due to different indications of the two techniques. RESULTS: 2711 PLBs and 30 TJLBs were evaluated. By PSM, 75 patients (50 PLBs, 25 TJLBs) were matched. The complication rates for TJLB and PLB were 4.0% (1/25) and 10.0% (5/50) (P > 0.05). Two PLBs had hepatic hemorrhage, one of which required only close monitoring (Grade 1) and the other needed hemostasis and rehydration therapy (Grade 2). The other 3 cases presented with mild abdominal pain (Grade 1). And only one TJLB presented with mild pain. The median number of complete portal tracts were 6.0 and 10.0 for TJLBs and PLBs (P < 0.05). Moreover, the median length of sample for TJLBs and PLBs were 10.0 and 16.5 mm (P < 0.05). The diagnostic efficiency of hepatopathy of unknown etiology of TJLB versus PLB groups before and after matching were 96.4% vs. 94.1% and 95.7% vs. 93.2%, respectively (P > 0.05). CONCLUSION: TJLB is an effective invasive diagnostic procedure that expands indications for liver biopsy with reliable diagnostic quality.


Assuntos
Hipertensão Portal , Hepatopatias , Humanos , Veias Jugulares/patologia , Fígado/patologia , Biópsia/efeitos adversos , Biópsia/métodos , Hepatopatias/patologia , Hipertensão Portal/etiologia , Hipertensão Portal/patologia , Dor Abdominal/etiologia
4.
Biomed Eng Online ; 22(1): 64, 2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37370077

RESUMO

BACKGROUND: Coronary computed tomography-derived fractional flow reserve (CT-FFR) and intravascular ultrasound-derived fractional flow reserve (IVUS-FFR) are two functional assessment methods for coronary stenoses. However, the calculation algorithms for these methods differ significantly. This study aimed to compare the diagnostic performance of CT-FFR and IVUS-FFR using invasive fractional flow reserve (FFR) as the reference standard. METHODS: Six hundred and seventy patients (698 lesions) with known or suspected coronary artery disease were screened for this retrospective analysis between January 2020 and July 2021. A total of 40 patients (41 lesions) underwent intravascular ultrasound (IVUS) and FFR evaluations within six months after completing coronary CT angiography were included. Two novel CFD-based models (AccuFFRct and AccuFFRivus) were used to compute the CT-FFR and IVUS-FFR values, respectively. The invasive FFR ≤ 0.80 was used as the reference standard for evaluating the diagnostic performance of CT-FFR and IVUS-FFR. RESULTS: Both AccuFFRivus and AccuFFRct demonstrated a strong correlation with invasive FFR (R = 0.7913, P < 0.0001; and R = 0.6296, P < 0.0001), and both methods showed good agreement with FFR. The area under the receiver operating characteristic curve was 0.960 (P < 0.001) for AccuFFRivus and 0.897 (P < 0.001) for AccuFFRct in predicting FFR ≤ 0.80. FFR ≤ 0.80 were predicted with high sensitivity (96.6%), specificity (85.7%), and the Youden index (0.823) using the same cutoff value of 0.80 for AccuFFRivus. A good diagnostic performance (sensitivity 89.7%, specificity 85.7%, and Youden index 0.754) was also demonstrated by AccuFFRct. CONCLUSIONS: AccuFFRivus, computed from IVUS images, exhibited a high diagnostic performance for detecting myocardial ischemia. It demonstrated better diagnostic power than AccuFFRct, and could serve as an accurate computational tool for ischemia diagnosis and assist in clinical decision-making.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Ultrassonografia de Intervenção/métodos , Angiografia por Tomografia Computadorizada , Valor Preditivo dos Testes
5.
Scand J Clin Lab Invest ; 83(5): 318-322, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37382084

RESUMO

BACKGROUND: Serum thyrotropin (TSH) has been recommended for the initial assessment of patients with thyroid nodules to exclude functional thyroid nodules (FTN). However, the sensitivity of TSH is very low. The increased level of thyroid peroxidase antibody (TPOAb) is considered to be one of the reasons. OBJECTIVE: To investigate whether normalized TSH (nTSH) can improve diagnostic efficiency by removing TPOAb interference in the first evaluation of thyroid nodules compared with traditional TSH strategy. METHODS: Thyroid nodules were retrospectively analysed in 90 patients with FTN and 1038 patients with non-functioning thyroid nodules (non-FTN). The regression coefficient (ß) of TPOAb affecting the TSH levels was assessed in patients with thyroid nodules, and then, the nTSH level was calculated based on the following formula: nTSH = TSH-ß*TPOAb. We used nTSH levels to initially evaluate the thyroid nodules instead of the traditional TSH values and finally compared the results of the two strategies. RESULTS: The sensitivity, specificity, accuracy, positive prediction rate (PPV) and negative prediction rate (NPV) of nTSH for accessing FTN were 50.00%, 87.70%, 84.67%, 26.01% and 95.29%, respectively, which were better than the values of 48.90%, 78.70%, 76.33%, 16.60% and 94.67% associated with TSH, respectively (p < 0.001). CONCLUSION: Serum TPOAb testing is recommended for the first assessment of thyroid nodules. Normalized TSH levels can improve assessment efficiency compared to traditional TSH assessment, increase the specificity and reduce an unnecessary 99mTc-TS test.


Assuntos
Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/diagnóstico , Estudos Retrospectivos , Tireotropina , Autoanticorpos , Iodeto Peroxidase
6.
Int J Clin Oncol ; 28(7): 880-892, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37142881

RESUMO

BACKGROUND: Our aim was to investigate the rationality and accuracy of plasma TrxR activity as an efficient tool in the early diagnosis of gastrointestinal malignancy, and whether TrxR can be used to evaluate the therapeutic efficacy of gastrointestinal malignancy. METHODS: We enrolled a total of 5091 cases, including 3736 cases in gastrointestinal malignancy, 964 in benign diseases, and 391 cases in healthy controls. We also performed receiver operating characteristic (ROC) analysis to evaluate diagnostic efficiency of TrxR. Finally, we detected pre- and post-treatment level of TrxR and common tumor markers. RESULTS: The plasma TrxR level in patients with gastrointestinal malignancy [8.4 (6.9, 9.7) U/mL] was higher than that in patients with benign disease [5.8 (4.6, 6.9) U/mL] and healthy control [3.5 (1.4, 5.4) U/mL]. Plasma TrxR showed a significant diagnostic advantage with an AUC of 0.897, compared with conventional tumor markers. In addition, the combination of TrxR and conventional tumor markers can further improve the diagnostic efficiency. We derived the optimal cut-off value of plasma TrxR as a diagnostic marker of gastrointestinal malignancy according to Youden index of 6.15 U/mL. After measuring the change trend of TrxR activity and conventional tumor markers before and after anti-tumor treatments, we found that their change trend was generally consistent, and the plasma TrxR activity was significantly decreased in patients treated with chemotherapy, targeted therapy and immunotherapy. CONCLUSIONS: Our findings recommend that plasma TrxR activity could be monitored as an efficient tool for the early diagnosis of gastrointestinal malignancy and as a feasible tool to evaluate the therapeutic effect.


Assuntos
Neoplasias Gastrointestinais , Tiorredoxina Dissulfeto Redutase , Humanos , Estudos Retrospectivos , Biomarcadores Tumorais , Neoplasias Gastrointestinais/diagnóstico , Neoplasias Gastrointestinais/tratamento farmacológico
7.
BMC Med Imaging ; 23(1): 190, 2023 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-37986051

RESUMO

BACKGROUND: This study aimed to compare the diagnostic efficiency of Ovarian-Adnexal Reporting and Data System (O-RADS) and doctors' subjective judgment in diagnosing the malignancy risk of adnexal masses. METHODS: This was an analysis of 616 adnexal masses between 2017 and 2020. The clinical findings, preoperative ultrasound images, and pathological diagnosis were recorded. Each adnexal mass was evaluated by doctors' subjective judgment and O-RADS by two senior doctors and two junior doctors. A mass with an O-RADS grade of 1 to 3 was a benign tumor, and a mass with an O-RADS grade of 4-5 was a malignant tumor. All outcomes were compared with the pathological diagnosis. RESULTS: Of the 616 adnexal masses, 469 (76.1%) were benign, and 147 (23.9%) were malignant. There was no difference between the area under the curve of O-RADS and the subjective judgment for junior doctors (0.83 (95% CI: 0.79-0.87) vs. 0.79 (95% CI: 0.76-0.83), p = 0.0888). The areas under the curve of O-RADS and subjective judgment were equal for senior doctors (0.86 (95% CI: 0.83-0.89) vs. 0.86 (95% CI: 0.83-0.90), p = 0.8904). O-RADS had much higher sensitivity than the subjective judgment in detecting malignant tumors for junior doctors (84.4% vs. 70.1%) and senior doctors (91.2% vs. 81.0%). In the subgroup analysis for detecting the main benign lesions of the mature cystic teratoma and ovarian endometriosic cyst, the junior doctors' diagnostic accuracy was obviously worse than the senior doctors' on using O-RADS. CONCLUSIONS: O-RADS had excellent performance in predicting malignant adnexal masses. It could compensate for the lack of experience of junior doctors to a certain extent. Better performance in discriminating various benign lesions should be expected with some complement.


Assuntos
Doenças dos Anexos , Neoplasias Ovarianas , Feminino , Humanos , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/patologia , Julgamento , Ultrassonografia/métodos , Medição de Risco , Sensibilidade e Especificidade , Estudos Retrospectivos
8.
J Ultrasound Med ; 42(11): 2661-2672, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37449666

RESUMO

OBJECTIVE: The present study assessed the diagnostic and prognostic significance of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) for suspected intrathoracic metastasis after HNC treatment. METHODS: A retrospective analysis was conducted on 75 patients with a prior history of head and neck cancer treatment who underwent EBUS-TBNA for suspected intrathoracic metastases between March 2012 and December 2021. RESULTS: A total of 126 targeted lesions, including 107 mediastinal/hilar lymph nodes and 19 intrapulmonary/mediastinal masses, were sampled. The metastatic head and neck cancer (HNC) cases detected by EBUS-TBNA consisted of nasopharyngeal carcinoma (n = 24), oropharyngeal carcinoma (n = 3), hypopharynx carcinoma (n = 6), laryngeal carcinoma (n = 6), and oral cavity carcinoma (n = 6). Cases with negative EBUS-TBNA results consisted of tuberculosis (n = 9), sarcoidosis (n = 3), anthracosis (n = 9), and reactive lymphadenitis (n = 9). Six false-negative cases were found among the 75 patients with suspected intrathoracic metastases. The diagnostic sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of the EBUS-TBNA procedure for metastatic HNC were 88.2, 100.0, 100.0, 80, and 92.0%, respectively. The diagnosis of HNC intrathoracic metastasis by EBUS-TBNA correlated with an adverse prognosis in terms of overall survival (OS) (P = .008). The log-rank univariate analysis and Cox regression multivariate analysis results indicated that the detection of metastatic HNC through EBUS-TBNA was a significant independent prognostic factor for patients with HNC who had received prior treatment. CONCLUSIONS: Endobronchial ultrasound-guided transbronchial needle aspiration is a safe, effective, and minimally invasive procedure for assessing suspected intrathoracic metastasis in HNC patients after treatment. The intrathoracic metastasis detected by EBUS-TBNA has crucial prognostic significance in previously treated HNC patients.


Assuntos
Carcinoma , Neoplasias de Cabeça e Pescoço , Neoplasias Pulmonares , Humanos , Prognóstico , Estudos Retrospectivos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Mediastino , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/patologia , Carcinoma/etiologia , Carcinoma/patologia , Neoplasias Pulmonares/patologia
9.
Anal Bioanal Chem ; 414(27): 7911-7922, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36138121

RESUMO

To investigate the diagnostic efficiency of Raman spectroscopy for the diagnosis of breast cancer, we searched PubMed, Web of Science, Cochrane Library, and Embase for articles published from the database establishment to May 20, 2022. Pooled sensitivity, specificity, diagnostic odds ratio, and area under the receiver pooled operating characteristic curve were derived for the included studies as outcome measures. The methodological quality was assessed according to the questionnaires and criteria suggested by the Diagnostic Accuracy Research Quality Assessment-2 tool. Sixteen studies were included in this meta-analysis. The pooled sensitivity and specificity of Raman spectroscopy for breast cancer diagnosis were 0.97 (95% CI, [0.92-0.99]) and 0.96 (95% CI, [0.91-0.98]). The diagnostic odds ratio was 720.89 (95% CI, [135.73-3828.88]) and the area under the curve of summary receiver operating characteristic curves was 0.99 (95% CI, [0.98-1]). Subgroup analysis revealed that all subgroup types in our analysis, including different races, sample types, diagnostic algorithms, number of spectra, instrument types, and laser wavelengths, turned out to have a sensitivity and specificity greater than 0.9. Significant heterogeneity was found between studies. Deeks' funnel plot demonstrated that publication bias was acceptable. This meta-analysis suggests that Raman spectroscopy may be an effective and accurate tool to differentiate breast cancer from normal breast tissue, which will help us diagnose and treat breast cancer.


Assuntos
Neoplasias da Mama , Neoplasias da Mama/diagnóstico , Feminino , Humanos , Curva ROC , Sensibilidade e Especificidade , Análise Espectral Raman/métodos
10.
Acta Radiol ; 63(9): 1147-1156, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34279135

RESUMO

BACKGROUND: There are inconsistencies when concomitantly using dynamic contrast enhancement (DCE) and intravoxel incoherent motion (IVIM) to evaluate diagnostic efficiency. PURPOSE: To evaluate the diagnostic efficiency of perfusion-related parameters in assessing the effect of Combretastatin-A4-phosphate (CA4P) in a rabbit VX2 liver tumor model using DCE and IVIM. MATERIAL AND METHODS: Twenty rabbits implanted with VX2 tumors were included in the study. The perfusion-parameters of DCE (Ktrans and iAUC60) and IVIM (f and D*) were measured at baseline and 4 h after administration of CA4P. Subsequently, the rabbits were euthanized. Pre- and post-treatment perfusion parameters were analyzed using paired t-test. Correlation between the various perfusion parameters and correlation of perfusion parameters with microvascular density (MVD) were assessed using Pearson correlation analysis. The diagnostic efficiency was evaluated using receiver operating characteristic (ROC) curve analysis. RESULTS: All perfusion parameters (Ktrans, iAUC60, f and D*) showed significant decrease after 4 h of CA4P administration (all P < 0.001). Post-treatment perfusion parameters showed a moderate correlation with MVD (r = 0.663, r = 0.567, r = 0.685, r = 0.618, respectively; all P < 0.05). At baseline and after treatment, Ktrans values and iAUC60 showed correlation with f and D* (all P < 0.05). Concomitant use of perfusion parameters of DCE and IVIM showed the best diagnostic performance, which was slightly greater than that observed with individual application of DCE or IVIM (AUC = 0.915, 0.880, and 0.895, respectively). CONCLUSION: Although concomitant application of DCE and IVIM can slightly improve the diagnostic value in assessing the effect of CA4P, the values were relatively small.


Assuntos
Meios de Contraste , Neoplasias Hepáticas , Animais , Imagem de Difusão por Ressonância Magnética , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/tratamento farmacológico , Movimento (Física) , Perfusão , Coelhos
11.
Cytopathology ; 33(4): 439-444, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35362154

RESUMO

OBJECTIVE: The efficacy of rapid on-site evaluation (ROSE) combined with computed tomography-guided transthoracic core needle biopsy (CT-guided TCNB) is rarely investigated. This study aimed to evaluate the diagnostic efficiency and safety of ROSE combined with CT-guided TCNB for suspected lung cancer patients. MATERIALS AND METHODS: Clinical data from 285 patients who received CT-guided TCNB for suspected lung cancer in Huashan Hospital from 2015 to 2018 were retrospectively analysed. Of these 163 patients underwent CT-guided TCNB combined with ROSE (ROSE group), while the remaining 122 patients underwent without ROSE (non-ROSE group). The smears from TCNB were quickly processed with Diff-Quick staining and analysed by a skilled cytologist on-site. The consistency of ROSE with the final clinicopathological diagnosis and the diagnostic efficiency and safety of ROSE combined with CT-guided TCNB in suspected lung cancer patients were evaluated. RESULTS: ROSE was highly concordant with pathological diagnosis (κ = 0.791; P < 0.001), with an accuracy of 95.7%. Diagnostic accuracy was significantly higher in the ROSE compared with the non-ROSE group (96.3% vs 86.1%; P = 0.002), with overall incidences of complications of 36.8% and 23.8%, respectively. Minor pneumothorax without drainage was slightly greater in the ROSE compared with the non-ROSE group (14.1% vs 6.6%; P = 0.046). However, there was no significant difference in serious complications between the two groups. CONCLUSION: ROSE was highly consistent with the final clinicopathological diagnosis for suspected lung cancer. ROSE further improved the diagnostic efficiency of CT-guided TCNB with no increased incidence of serious complications.


Assuntos
Neoplasias Pulmonares , Avaliação Rápida no Local , Biópsia com Agulha de Grande Calibre , Humanos , Biópsia Guiada por Imagem , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
12.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 47(8): 1082-1088, 2022 Aug 28.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-36097776

RESUMO

OBJECTIVES: International Ovarian Tumor Analysis (IOTA) working group proposed a logistic regression (IOTA LR2) model. It is served as a risk prediction model for benign and malignant adnexal tumors. This study aims to compare the diagnostic efficiency between the IOTA LR2 model and doctors' subjective assessment on diagnosing benign and malignant adnexal mass. METHODS: The ultrasonographic images of 616 adnexal masses were retrospectively analyzed by the senior doctors' group and the junior doctors' group using the IOTA LR2 model and subjective assessment. The postoperative pathological diagnosis was used as the gold standard to compare the diagnostic efficiency of the 2 methods. RESULTS: The area under the curves of subjective assessment and IOTA LR2 model for diagnosing malignant adnexal masses were 0.86 and 0.90 for the senior doctors' group and 0.79 and 0.88 for the junior doctors' group, respectively. The sensitivity and specificity of subjective assessment for diagnosing the malignant adnexal masses were 81.0% and 91.3% for the senior doctors' group and 70.1% and 88.7% for the junior doctors' group, respectively. The sensitivity and specificity of the IOTA LR2 model for diagnosing the malignant adnexal masses were 79.6% and 88.1% for the senior doctors' group, and 79.6% and 81.7% for the junior doctors' group, respectively.There were no significant difference in the sensitivities between the senior doctors' group and junior doctors' group using the IOTA LR2 model and the senior doctors' group using subjective assessment (both P>0.05). CONCLUSIONS: The diagnostic efficiency of the IOTA LR2 model is equal to the senior doctors' experiences. This model can help junior doctors to reduce the missed diagnosis of malignant adnexal masses.


Assuntos
Doenças dos Anexos , Neoplasias Ovarianas , Doenças dos Anexos/diagnóstico , Doenças dos Anexos/patologia , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Ovarianas/diagnóstico por imagem , Estudos Retrospectivos
13.
Scand J Clin Lab Invest ; 81(8): 641-648, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34779329

RESUMO

Currently, islet autoantibodies (IAbs) constitute the most reliable marker for detecting the autoimmune process of type 1 diabetes (T1D). However, there are no appropriate reference intervals (RIs) to interpret the results of IAbs in China. In this study, we aimed to establish the RIs of four common IAbs based on the Han Chinese population and evaluate their clinical diagnostic values in patients with T1D. We collected 177 blood samples from healthy volunteers to detect the levels of IAbs directed against insulin (IAA), glutamic acid decarboxylase-65 (GADA), insulinoma antigen 2 (IA-2A), and zinc transporter-8 (ZnT8A) using a chemiluminescence immunoassay. RIs were calculated using nonparametric 95th percentile intervals in accordance with the Clinical and Laboratory Standards Institute guidelines, and their clinical diagnostic values were evaluated by detecting the levels of IAbs of 140 blood samples from patients with T1D in a clinical setting. We defined 138 individuals as the apparently healthy population from the 177 healthy volunteers based on the exclusion criteria. No association between the levels of the four IAbs and gender (p > .05) and age (p > .05) were found in the apparently healthy population. The combined RIs for GADA, IA-2A, ZnT8A, and IAA were 0-1.78 IU/mL, 0-3.91 IU/mL, 0-2.36 AU/mL, and 0-0.58 COI, respectively. Overall, the diagnostic efficiency for the four IAbs, especially for GADA and IAA, were improved by using the RIs established in this study. The RIs for IAbs established in this study will be a valuable tool for disease diagnosis and the therapeutic management of T1D in a clinical setting.


Assuntos
Diabetes Mellitus Tipo 1 , Povo Asiático , Autoanticorpos , Glutamato Descarboxilase , Humanos , Insulina
14.
Adv Health Sci Educ Theory Pract ; 26(3): 847-863, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33599875

RESUMO

When physicians are asked to determine the positive predictive value from the a priori probability of a disease and the sensitivity and false positive rate of a medical test (Bayesian reasoning), it often comes to misjudgments with serious consequences. In daily clinical practice, however, it is not only important that doctors receive a tool with which they can correctly judge-the speed of these judgments is also a crucial factor. In this study, we analyzed accuracy and efficiency in medical Bayesian inferences. In an empirical study we varied information format (probabilities vs. natural frequencies) and visualization (text only vs. tree only) for four contexts. 111 medical students participated in this study by working on four Bayesian tasks with common medical problems. The correctness of their answers was coded and the time spent on task was recorded. The median time for a correct Bayesian inference is fastest in the version with a frequency tree (2:55 min) compared to the version with a probability tree (5:47 min) or to the text only versions based on natural frequencies (4:13 min) or probabilities (9:59 min).The score diagnostic efficiency (calculated by: median time divided by percentage of correct inferences) is best in the version with a frequency tree (4:53 min). Frequency trees allow more accurate and faster judgments. Improving correctness and efficiency in Bayesian tasks might help to decrease overdiagnosis in daily clinical practice, which on the one hand cause cost and on the other hand might endanger patients' safety.


Assuntos
Médicos , Estudantes de Medicina , Teorema de Bayes , Humanos , Probabilidade , Resolução de Problemas
15.
BMC Pulm Med ; 21(1): 224, 2021 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-34247611

RESUMO

OBJECTIVE: To evaluate the accuracy and safety of contrast-enhanced ultrasound (CEUS) guided biopsy in the diagnosis of radiologically determined pleural based lesions. METHOD: A prospective study was conducted on patients with radiologically determined pleural based lesions. Patients who met the inclusion criteria received pleural biopsy guided by CEUS to obtain specimens, followed by histomathological and microbiological examinations. After treatment and follow-up, surgical thoracoscopy was performed on cases with undefinite diagnosis. RESULT: A total of 460 patients were finally included. CEUS showed internal necrosis in 72.17% cases and obvious peripheral vessels in 55.43% cases, both of which were significantly higher than the conventional ultrasound imaged (p < 0.05). The diagnostic accuracy through CEUS guided biopsy sampling was 98.91% (455/460). The microbiological diagnostic yield achieved 71.88% (225/313) in infectious lesions. In 330 cases combined pleural effusion, CEUS guided biopsy increased the diagnostic yield from 60.30% (199 /330) to 98.36% (325 /330) in all cases (p < 0.05), from 15.56% (14/90) to 94.44% (85/90) in malignant lesions (p < 0.01) and from 77.08% (185/240) to 100% (240/240) in infectious lesions (p < 0.05). No serious adverse events occurred. CONCLUSION: CEUS guided biopsy provides a minimally invasive, effective and safe diagnostic biopsy method for pleural lesions. CLINICAL TRIALS REGISTRATION: Chinese Clinical Trial Registry ChiCTR2000029749 (ChiCTR, www.chictr.org.cn ).


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Pleura/patologia , Derrame Pleural/patologia , Ultrassonografia de Intervenção/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pleura/diagnóstico por imagem , Derrame Pleural/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
16.
J Clin Lab Anal ; 35(11): e24008, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34545638

RESUMO

BACKGROUND: Recently, measurement of serum circular RNAs (circRNAs) as a non-invasive tumor marker has been considered more. We designed the present study to investigate the diagnostic efficiency of serum Circ-ELP3 and Circ-FAF1, separately and simultaneously, for diagnosis of patients with breast cancer. METHODS: Seventy-eight female patients diagnosed as primary breast cancer participated in this study. We measured the level of circRNAs in serum specimens of the studied subjects. A receiver operating characteristic (ROC) curve was plotted and the diagnostic efficiency for both circRNAs was determined. RESULTS: Compared to non-cancerous controls, Circ-ELP3 was upregulated in breast cancer patients (p-value = 0.004). On the other hand, serum Circ-FAF1 was seen to be decreased in breast cancer patients than controls (p-value = 0.001). According to ROC curve results, the area under the curve (AUC) for Circ-ELP3 and Circ-FAF1 was 0.733 and 0.787, respectively. Furthermore, the calculated sensitivity and specificity for Circ-ELP3 and Circ-FAF1 were 65, 64% and 77, 74%, respectively. Merging both circRNAs increased the diagnostic efficiency, with a better AUC, sensitivity and specificity values of 0.891, 96 and 62%, respectively. CONCLUSION: Briefly, our results revealed the high diagnostic value for combined circRNAs panel, including Circ-ELP3 and Circ-FAF1 as a non-invasive marker, in detection of breast carcinomas.


Assuntos
Biomarcadores Tumorais/sangue , Neoplasias da Mama/diagnóstico , RNA Circular/sangue , Adulto , Neoplasias da Mama/sangue , Neoplasias da Mama/epidemiologia , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC
17.
Nephrology (Carlton) ; 25(9): 667-675, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32147922

RESUMO

BACKGROUND: Early screening of diabetic kidney disease (DKD) remains a major challenge. Our aim was to evaluate the value of urinary orosomucoid 1 protein (UORM1) in early renal impairment screening in type-2 diabetes patients. METHODS: The concentration of UORM1, the UORM1-to-creatinine ratio (UORM1CR), the urinary albumin-to-creatinine ratio (ACR), the alpha-1-microglobulin-to-creatinine ratio (A1MCR) and estimated glomerular filtration rate (eGFR) were measured in 406 type-2 diabetes patients. Any positive values for ACR, A1MCR and/or eGFR were considered as indicative of renal impairment. RESULTS: On average, the levels of UORM1 and UORM1CR were about seven times higher in subjects with renal injury than in those without. Both UORM1 and UORM1CR, when adjusted via logarithm-transformation, were significantly related to ACR, A1MCR and eGFR levels. The highest correlation was observed between UORM1CR and A1MCR (r = 0.85, P < .001). The cut-off values for UORM1 (2.53 mg/L) and UORM1CR (3.69 mg/g) for the early diagnosis of kidney impairment were obtained from receiver operating characteristic curves. UORM1CR obviously had higher diagnostic efficiency corresponding to 83.26% sensitivity and 90.32% specificity than UORM1. Likewise, its sensitivity was higher than those of ACR, A1MCR and eGFR. Bad glycaemic control had the highest risk of increased UORM1CR (odds ratio [OR] = 2.81, P < .001), while high HDL-C (high-density lipoprotein cholesterol) decreased the risk of increased UORM1CR (OR = 0.38, P = .017). CONCLUSION: The UORM1CR (>3.69 mg/g) has the high diagnostic efficiency for the early screening of renal impairment in type-2 diabetes patients. Furthermore, good glycaemic control and high HDL-C might be protective factors against UORM1CR increase.


Assuntos
Diabetes Mellitus Tipo 2 , Nefropatias Diabéticas , Controle Glicêmico/métodos , Orosomucoide/urina , alfa-Globulinas/análise , Biomarcadores/urina , China/epidemiologia , HDL-Colesterol/sangue , Correlação de Dados , Creatinina/análise , Estudos Transversais , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/metabolismo , Diabetes Mellitus Tipo 2/fisiopatologia , Nefropatias Diabéticas/diagnóstico , Nefropatias Diabéticas/epidemiologia , Nefropatias Diabéticas/etiologia , Nefropatias Diabéticas/metabolismo , Diagnóstico Precoce , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Proteção , Fatores de Risco , Urinálise/métodos
18.
Beijing Da Xue Xue Bao Yi Xue Ban ; 53(1): 133-138, 2020 Dec 29.
Artigo em Chinês | MEDLINE | ID: mdl-33550347

RESUMO

OBJECTIVE: To investigate the correlation between morphological stages of midpalatal suture (MPS) and Demirjian dental age. METHODS: In this retrospective study, 1 076 cone-beam CT (CBCT) images (female: 675, male: 401; age range: 6.0 to 21.0 years) were included. Horizontal view of each sample's CBCT images was observed, each sample's MPS stage was recorded, and dental age. MPS stage and dental age were ordered with categorical variables. Therefore, their correlation was investigated through Spearman correlation coefficient analysis and diagnostic test analysis. RESULTS: (1) For left lower second premolar: 95.2% of those in dental age stage B-D were in MPS 1-2, accounting for the largest proportion. 85.3% of those in dental age stage E were in MPS 1-2, still accounting for the largest proportion. Another 14.7% were in MPS 3.45.1% of those in dental age stage F were in MPS 3, 46.1% in MPS 1-2, and another 8.8% in MPS 4s1.49.8% of those in dental age stage G were in MPS 3.24.9% in MPS 4s1, and 18.9% in MPS 1-2.80.1% of those in dental age stage H were in MPS 4-5. Another 16.3% were in MPS 3. (2) For left lower second molar: 89.7% of those in dental age stage B-D were in MPS 1-2, accounting for the largest proportion. 67.4% of those in dental age stage E were in MPS 1-2, still accounting for the largest proportion. Another 26.1% were in MPS 3.55.3% of those in dental age stage F were in MPS 3, 34.2% in MPS 1-2, and another 10.5% in MPS 4s1.50.7% of those in dental age stage G were in MPS 3, 24.3% in MPS 4s1, and 16.8% in MPS 1-2.83.8% of those in dental age stage H were in MPS 4-5, another 14.2% were in MPS 3. (3) To diagnose MPS stage with dental age, diagnostic pairs with good performance included: Dental age of left lower second molar-MPS: H-4s2, H-5, D-1; Dental age of left lower second premolar-MPS: H-4s2, H-5, G-3. Other diagnostic pairs were of ordinary diagnostic efficiency. (4) For dental age-MPS Spearman correlation analysis, dental age of left lower second molar-MPS had the highest Spearman coefficient (0.68), dental age of left lower second premolar-MPS was the second high (0.64). (5) Dental age stage H of left lower second molar or left lower second premolar indicated that the individual was later than MPS 4s2. CONCLUSION: Dental age's diagnostic efficiency for MPS stage is ordinary on the whole, except for some pairs with good performance. Therefore, pre-treatment CBCT examination should be considered as assistance for evaluating maturation and fusion status of midpalatal suture.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Suturas Cranianas , Adolescente , Adulto , Criança , China , Suturas Cranianas/diagnóstico por imagem , Feminino , Humanos , Masculino , Estudos Retrospectivos , Suturas , Adulto Jovem
19.
Dig Dis Sci ; 64(10): 2911-2922, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31032524

RESUMO

BACKGROUND: The elderly assess higher incidence of gastric diseases and may meet challenges and contraindications when flexible esophagogastroduodenoscopy intubating. Magnetic-controlled capsule endoscopy (MCE) is declared as a promising alternative, but its applications in elderly population do not attach enough importance. AIMS: To explore MCE's efficiency and safety in the elderly. METHODS: A single-center retrospective study has been conducted. Data from the elderly group (>65 year-old) who underwent MCE examination, including indications, MCE outcomes, gastric conditions, evaluations from MCE manipulators and endoscopists, subjective discomforts, adverse events, etc., had been collected, then analyzed, and compared with the ones from the middle-aged group (>40, ≤ 65 year-old). RESULTS: During April 2015 and September 2018, 98 elderly patients and 72 middle-aged patients underwent MCE examination. In the elderly, the indications included poor physical condition (28.6%), severe angiocardiopathy (39.8%), EGD rejection (13.3%), severe respiratory disorder (8.2%), craniocerebral injury (8.2%), and allergy to anesthetics (2.0%). Rate of complete gastric observation and positive finding were 98.0% and 72.4% (vs. middle-aged group, 94.4%, 56.9%, P = 0.220, 0.035), and gastric conditions showed relatively inferior. Gastric preparation and MCE procedure were generally tolerated, but three elderly patients (3.1%) experienced capsule blockage in stomach. CONCLUSIONS: Our preliminary data support that MCE offers considerable benefit and is general safe for the elderly. We hope such data promote greater awareness of innovative attempts for the specific elderly, and expect multi-center, large-scale trials with randomized controlled design bring optimized strategies for better gastric visibility, efficacy and lower potential risk.


Assuntos
Endoscopia por Cápsula , Imãs , Gastropatias/diagnóstico , Estômago/diagnóstico por imagem , Fatores Etários , Idoso , Endoscopia por Cápsula/efeitos adversos , Endoscopia por Cápsula/instrumentação , Endoscopia por Cápsula/métodos , China/epidemiologia , Feminino , Avaliação Geriátrica/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Reprodutibilidade dos Testes , Estudos Retrospectivos , Gastropatias/epidemiologia , Resultado do Tratamento
20.
J Obstet Gynaecol Res ; 45(8): 1515-1521, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31141845

RESUMO

AIM: To evaluate whether using multiple displacement amplification (MDA) as the first step can increase the diagnostic efficiency of preimplantation genetic testing for monogenic disease (PGT-M) for ß-thalassemia. METHODS: This is a retrospective cohort study. All included patients underwent PGT-M cycles (n = 307) for ß-thalassemia in our center from January 2014 to February 2018. We divided the patients into two groups based on two different detection methods. For the polymerase chain reaction (PCR) group (n = 115), multiplex nested PCR+ reverse dot blot analysis was performed directly after cell lysis. For the MDA group (n = 192), the whole genomes of single cells were directly amplified using MDA and then examined by singleplex PCR + reverse dot blot for ß-thalassemia. RESULTS: A total of 2315 embryos were tested. The overall diagnostic efficiency of the MDA group was significantly higher than that of the PCR group (96.99% vs 88.15%, P < 0.001). The percentage of embryos available for transfer was significantly higher in the MDA group than in the PCR group (74.28% vs 64.98%, P < 0.001). Furthermore, the carrier embryo rate of the MDA group was significantly higher than that of the PCR group (50.11% vs 35.95%, P < 0.001). CONCLUSION: This study indicates that MDA, as the first step in PGT-M for ß-thalassemia, can increase diagnostic efficiency.


Assuntos
Transferência Embrionária , Fertilização in vitro , Testes Genéticos/normas , Técnicas de Amplificação de Ácido Nucleico/normas , Diagnóstico Pré-Implantação/normas , Talassemia beta/diagnóstico , Adulto , Feminino , Humanos , Masculino , Reação em Cadeia da Polimerase/normas , Estudos Retrospectivos , Talassemia beta/genética
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa