Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 351
Filtrar
1.
Br J Ophthalmol ; 108(3): 349-356, 2024 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36653163

RESUMO

BACKGROUND: Glaucoma staging is critical for treatment planning but has rarely been tested in severe/end-stage disease. We compared the performance of the Disc Damage Likelihood Scale (DDLS) and cup:disc ratio (CDR) using a functional glaucoma staging system (GSS) as the reference standard. METHODS: Post hoc analysis of a randomised controlled trial at the Eye Department of Kilimanjaro Christian Medical Centre, Tanzania. Eligible participants (aged ≥18 years) with open-angle glaucoma, intraocular pressure (IOP) of >21 mm Hg, were randomised to timolol 0.5% eye drops or selective laser trabeculoplasty. Fundoscopy established vertical and horizontal CDRs and DDLS. Visual acuity and static visual fields were graded (GSS). The study used area under the receiver operating characteristic (AROC) curves and Spearman's rank correlation coefficients to compare staging systems. Logistic regression with generalised estimating equations determined risk factors of functional severe/end-stage glaucoma. RESULTS: 382 eyes (201 participants) were evaluated; 195 (51%) had severe or end-stage glaucoma; mean IOP was 26.7 (SD 6.9) mm Hg. DDLS yielded an AROC of 0.90 (95% CI 0.87 to 0.93), vertical cup:disc ratio (vCDR) of 0.88 (95% CI 0.85 to 0.91, p=0.048) for identifying severe/end-stage disease. Correlation coefficients comparing GSS to DDLS and vCDRs were 0.73 and 0.71, respectively. Advanced structural stages, vision impairment, higher IOP and less financial resources were risk factors of functional severe/end-stage glaucoma. CONCLUSION: This study indicates that both structural staging systems can differentiate severe/end-stage glaucoma from less severe disease, with a moderate advantage of DDLS over CDR. Clinical examination of the optic disc plays an important role in addition to functional assessment when managing severe/end-stage glaucoma.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Doenças do Nervo Óptico , Humanos , Adolescente , Adulto , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/complicações , Doenças do Nervo Óptico/diagnóstico , Tanzânia , Pressão Intraocular , Transtornos da Visão/diagnóstico , Funções Verossimilhança
2.
Br J Ophthalmol ; 108(3): 417-423, 2024 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36720585

RESUMO

AIMS: To develop an algorithm to classify multiple retinal pathologies accurately and reliably from fundus photographs and to validate its performance against human experts. METHODS: We trained a deep convolutional ensemble (DCE), an ensemble of five convolutional neural networks (CNNs), to classify retinal fundus photographs into diabetic retinopathy (DR), glaucoma, age-related macular degeneration (AMD) and normal eyes. The CNN architecture was based on the InceptionV3 model, and initial weights were pretrained on the ImageNet dataset. We used 43 055 fundus images from 12 public datasets. Five trained ensembles were then tested on an 'unseen' set of 100 images. Seven board-certified ophthalmologists were asked to classify these test images. RESULTS: Board-certified ophthalmologists achieved a mean accuracy of 72.7% over all classes, while the DCE achieved a mean accuracy of 79.2% (p=0.03). The DCE had a statistically significant higher mean F1-score for DR classification compared with the ophthalmologists (76.8% vs 57.5%; p=0.01) and greater but statistically non-significant mean F1-scores for glaucoma (83.9% vs 75.7%; p=0.10), AMD (85.9% vs 85.2%; p=0.69) and normal eyes (73.0% vs 70.5%; p=0.39). The DCE had a greater mean agreement between accuracy and confident of 81.6% vs 70.3% (p<0.001). DISCUSSION: We developed a deep learning model and found that it could more accurately and reliably classify four categories of fundus images compared with board-certified ophthalmologists. This work provides proof-of-principle that an algorithm is capable of accurate and reliable recognition of multiple retinal diseases using only fundus photographs.


Assuntos
Aprendizado Profundo , Retinopatia Diabética , Glaucoma , Degeneração Macular , Oftalmologistas , Humanos , Fundo de Olho , Redes Neurais de Computação , Degeneração Macular/diagnóstico por imagem , Retinopatia Diabética/diagnóstico por imagem , Glaucoma/diagnóstico
3.
Br J Ophthalmol ; 108(2): 268-273, 2024 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-36746615

RESUMO

BACKGROUND/AIMS: Deep learning systems (DLSs) for diabetic retinopathy (DR) detection show promising results but can underperform in racial and ethnic minority groups, therefore external validation within these populations is critical for health equity. This study evaluates the performance of a DLS for DR detection among Indigenous Australians, an understudied ethnic group who suffer disproportionately from DR-related blindness. METHODS: We performed a retrospective external validation study comparing the performance of a DLS against a retinal specialist for the detection of more-than-mild DR (mtmDR), vision-threatening DR (vtDR) and all-cause referable DR. The validation set consisted of 1682 consecutive, single-field, macula-centred retinal photographs from 864 patients with diabetes (mean age 54.9 years, 52.4% women) at an Indigenous primary care service in Perth, Australia. Three-person adjudication by a panel of specialists served as the reference standard. RESULTS: For mtmDR detection, sensitivity of the DLS was superior to the retina specialist (98.0% (95% CI, 96.5 to 99.4) vs 87.1% (95% CI, 83.6 to 90.6), McNemar's test p<0.001) with a small reduction in specificity (95.1% (95% CI, 93.6 to 96.4) vs 97.0% (95% CI, 95.9 to 98.0), p=0.006). For vtDR, the DLS's sensitivity was again superior to the human grader (96.2% (95% CI, 93.4 to 98.6) vs 84.4% (95% CI, 79.7 to 89.2), p<0.001) with a slight drop in specificity (95.8% (95% CI, 94.6 to 96.9) vs 97.8% (95% CI, 96.9 to 98.6), p=0.002). For all-cause referable DR, there was a substantial increase in sensitivity (93.7% (95% CI, 91.8 to 95.5) vs 74.4% (95% CI, 71.1 to 77.5), p<0.001) and a smaller reduction in specificity (91.7% (95% CI, 90.0 to 93.3) vs 96.3% (95% CI, 95.2 to 97.4), p<0.001). CONCLUSION: The DLS showed improved sensitivity and similar specificity compared with a retina specialist for DR detection. This demonstrates its potential to support DR screening among Indigenous Australians, an underserved population with a high burden of diabetic eye disease.


Assuntos
População Australasiana , Aprendizado Profundo , Diabetes Mellitus , Retinopatia Diabética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Austrália , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/epidemiologia , Etnicidade , Grupos Minoritários , Estudos Retrospectivos , Povos Aborígenes Australianos e Ilhéus do Estreito de Torres
4.
Br J Ophthalmol ; 108(3): 424-431, 2024 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36878715

RESUMO

BACKGROUND/AIMS: This study evaluates the performance of the Airdoc retinal artificial intelligence system (ARAS) for detecting multiple fundus diseases in real-world scenarios in primary healthcare settings and investigates the fundus disease spectrum based on ARAS. METHODS: This real-world, multicentre, cross-sectional study was conducted in Shanghai and Xinjiang, China. Six primary healthcare settings were included in this study. Colour fundus photographs were taken and graded by ARAS and retinal specialists. The performance of ARAS is described by its accuracy, sensitivity, specificity and positive and negative predictive values. The spectrum of fundus diseases in primary healthcare settings has also been investigated. RESULTS: A total of 4795 participants were included. The median age was 57.0 (IQR 39.0-66.0) years, and 3175 (66.2%) participants were female. The accuracy, specificity and negative predictive value of ARAS for detecting normal fundus and 14 retinal abnormalities were high, whereas the sensitivity and positive predictive value varied in detecting different abnormalities. The proportion of retinal drusen, pathological myopia and glaucomatous optic neuropathy was significantly higher in Shanghai than in Xinjiang. Moreover, the percentages of referable diabetic retinopathy, retinal vein occlusion and macular oedema in middle-aged and elderly people in Xinjiang were significantly higher than in Shanghai. CONCLUSION: This study demonstrated the dependability of ARAS for detecting multiple retinal diseases in primary healthcare settings. Implementing the AI-assisted fundus disease screening system in primary healthcare settings might be beneficial in reducing regional disparities in medical resources. However, the ARAS algorithm must be improved to achieve better performance. TRIAL REGISTRATION NUMBER: NCT04592068.


Assuntos
Retinopatia Diabética , Drusas Retinianas , Pessoa de Meia-Idade , Idoso , Humanos , Feminino , Masculino , Inteligência Artificial , Estudos Transversais , Sensibilidade e Especificidade , China/epidemiologia , Retinopatia Diabética/diagnóstico , Atenção Primária à Saúde , Programas de Rastreamento
5.
Br J Ophthalmol ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485214

RESUMO

PURPOSE: To develop and validate a deep learning model for the segmentation of five retinal biomarkers associated with neovascular age-related macular degeneration (nAMD). METHODS: 300 optical coherence tomography volumes from subject eyes with nAMD were collected. Images were manually segmented for the presence of five crucial nAMD features: intraretinal fluid, subretinal fluid, subretinal hyperreflective material, drusen/drusenoid pigment epithelium detachment (PED) and neovascular PED. A deep learning architecture based on a U-Net was trained to perform automatic segmentation of these retinal biomarkers and evaluated on the sequestered data. The main outcome measures were receiver operating characteristic curves for detection, summarised using the area under the curves (AUCs) both on a per slice and per volume basis, correlation score, enface topography overlap (reported as two-dimensional (2D) correlation score) and Dice coefficients. RESULTS: The model obtained a mean (±SD) AUC of 0.93 (±0.04) per slice and 0.88 (±0.07) per volume for fluid detection. The correlation score (R2) between automatic and manual segmentation obtained by the model resulted in a mean (±SD) of 0.89 (±0.05). The mean (±SD) 2D correlation score was 0.69 (±0.04). The mean (±SD) Dice score resulted in 0.61 (±0.10). CONCLUSIONS: We present a fully automated segmentation model for five features related to nAMD that performs at the level of experienced graders. The application of this model will open opportunities for the study of morphological changes and treatment efficacy in real-world settings. Furthermore, it can facilitate structured reporting in the clinic and reduce subjectivity in clinicians' assessments.

6.
BMJ Open Ophthalmol ; 9(1)2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39142698

RESUMO

AIMS: To explore the sensitive components of full-field electroretinography (ERG) as indicators of retina function at the onset of acute ischaemic central retinal vein occlusion (CRVO). METHODS: 11 patients (11 eyes) with ischaemic CRVO and 32 patients (32 eyes) with non-ischaemic CRVO who presented with first-episode unilateral CRVO within 1 month of symptom onset and with no previous intervention were examined by the International Society for Clinical Electrophysiology of Vision standard ERG. RESULTS: A significant amplitude decline and peak time delay in light-adapted (LA) 3 ERG and LA 30 Hz flicker ERG (p<0.05 for all) was found in the ischaemic CRVO eyes, compared with the non-ischaemic CRVO eyes. The b/a amplitude ratio of dark-adapted (DA) 3 ERG, DA 10 ERG and LA 3 ERG was significantly different between the ischaemic and non-ischaemic groups (p<0.05 for all). Regarding oscillatory potentials (OPs), the amplitudes of OP1, OP2 and OP3 as well as the sum of DA 3 OP1-4 amplitudes (∑OPs) showed significant changes (p<0.01 for all) between two groups. No peak time delay of OPs was found between the ischaemic and non-ischaemic CRVO eyes. CONCLUSION: The amplitude of DA 0.01 ERG, components of LA 3 ERG and LA 30 Hz flicker ERG, and the b/a amplitude ratio could be among the most sensitive indicators in patients with acute ischaemic CRVO. The amplitudes of OP1, OP2, OP3 and ∑OPs in the CRVO eyes were reduced to 40% of the control values, showing that this quantitative method is reliable for detecting ischaemic retinal diseases, even in early stage.


Assuntos
Eletrorretinografia , Isquemia , Retina , Oclusão da Veia Retiniana , Humanos , Oclusão da Veia Retiniana/fisiopatologia , Oclusão da Veia Retiniana/diagnóstico , Eletrorretinografia/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Doença Aguda , Isquemia/fisiopatologia , Isquemia/diagnóstico , Retina/fisiopatologia , Retina/diagnóstico por imagem , Acuidade Visual/fisiologia , Adaptação à Escuridão/fisiologia , Adulto
7.
BMJ Open Ophthalmol ; 9(1)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609325

RESUMO

OBJECTIVE: The objective of this study is to determine the validity and reliability of the red filter meibography by smartphone compared with infrared in assessing meibomian gland drop-out. METHODS AND ANALYSIS: An analytical cross-sectional study was done with a total of 35 subjects (68 eyes) with suspected MGD based on symptoms and lid morphological abnormalities. Meibomian glands were photographed using two smartphones (Samsung S9 and iPhone XR) on a slit-lamp with added red filter. Images were assessed subjectively using meiboscore by the two raters and drop-out percentages were assessed by ImageJ. RESULTS: There was no agreement in meiboscore and a minimal level of agreement in drop-out percentages between red filter meibography and infrared. Inter-rater reliability showed no agreement between two raters. Intra-rater reliability demonstrated weak agreement in rater 1 and no agreement in rater 2. CONCLUSION: Validity of the red filter meibography technique by smartphones is not yet satisfactory in evaluating drop-out. Further improvement on qualities of images must be done and research on subjective assessment was deemed necessary due to poor results of intrarater and inter-rater reliability.


Assuntos
Disfunção da Glândula Tarsal , Humanos , Smartphone , Estudos Transversais , Reprodutibilidade dos Testes , Glândulas Tarsais/diagnóstico por imagem
8.
Br J Ophthalmol ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485215

RESUMO

BACKGROUND: Artificial intelligence (AI) in medical imaging diagnostics has huge potential, but human judgement is still indispensable. We propose an AI-aided teaching method that leverages generative AI to train students on many images while preserving patient privacy. METHODS: A web-based course was designed using 600 synthetic ultra-widefield (UWF) retinal images to teach students to detect disease in these images. The images were generated by stable diffusion, a large generative foundation model, which we fine-tuned with 6285 real UWF images from six categories: five retinal diseases (age-related macular degeneration, glaucoma, diabetic retinopathy, retinal detachment and retinal vein occlusion) and normal. 161 trainee orthoptists took the course. They were evaluated with two tests: one consisting of UWF images and another of standard field (SF) images, which the students had not encountered in the course. Both tests contained 120 real patient images, 20 per category. The students took both tests once before and after training, with a cool-off period in between. RESULTS: On average, students completed the course in 53 min, significantly improving their diagnostic accuracy. For UWF images, student accuracy increased from 43.6% to 74.1% (p<0.0001 by paired t-test), nearly matching the previously published state-of-the-art AI model's accuracy of 73.3%. For SF images, student accuracy rose from 42.7% to 68.7% (p<0.0001), surpassing the state-of-the-art AI model's 40%. CONCLUSION: Synthetic images can be used effectively in medical education. We also found that humans are more robust to novel situations than AI models, thus showcasing human judgement's essential role in medical diagnosis.

9.
Br J Ophthalmol ; 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39084884

RESUMO

BACKGROUND/AIMS: Recent decades have seen significant advances in both structural and functional testing of retinal disease. However, the current clinical value of specific testing modalities, as well as future trends, need to be clearly identified in order to highlight areas for further development in routine care and clinical trials. METHODS: We designed a modified two-round Delphi study to obtain the opinion of a multidisciplinary group of 33 international experts involved in the field of retinal disease management/research to determine the level of agreement and consensus regarding the value and performance of specific structural and functional testing methods for retinal disease. On a Likert scale, a median of 1-2 indicated disagreement with the statement, and 5-6 indicated agreement with the statement. An IQR of ≤2 indicated consensus in the responses. Several questions also allowed comments on responses. RESULTS: There was overall agreement that structural testing currently predominates for detection and monitoring. There was moderate agreement that functional testing remains important and will continue to do so in the future because it provides complementary information. Certain respondents considered that properly designed and applied psychophysical tests are as reliable and repeatable as structural observations and that functional changes are the most important in the long run. Respondents considered future care and research to require a combination of structural and functional testing with strong consensus that the relative importance will depend on disease type and stage. CONCLUSION: The study obtained important insights from a group of international experts regarding current and future needs in the management of retinal disease using a mix of quantitative and qualitative approaches. Responses provide a rich range of opinions that will be of interest to researchers seeking to design tests for future patient care and clinical trials.

10.
Br J Ophthalmol ; 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39122355

RESUMO

BACKGROUND/AIMS: Female choroideremia carriers present with a spectrum of disease severity. Unlike in men, the rate of disease progression has not been well characterised in carriers. This longitudinal study aimed to determine the rate of retinal degeneration in choroideremia carriers, using multimodal imaging and microperimetry. METHODS: Choroideremia carriers previously seen at Oxford Eye Hospital (United Kingdom) between 2012 and 2017 returned for testing between 2015 and 2023, providing up to 11 years' follow-up data. Participants had optical coherence tomography, fundus-tracked microperimetry and fundus autofluorescence (FAF) imaging performed. RESULTS: Thirty-four eyes of 17 choroideremia carriers were examined using multimodal imaging. Median age was 44 (range: 15-73) years at baseline and median follow-up duration was 7 (range: 1-11) years. At baseline, phenotype was classified as fine (n=5 eyes), coarse (n=13 eyes), geographic (n=12 eyes) or male pattern (n=4 eyes). Thirteen patients showed no change in phenotype classification, four showed slight changes associated with choroideremia-related retinal degeneration. Despite this, carriers with severe retinal phenotypes had a statistically significant decline in average retinal sensitivity (-0.7 dB and -0.8 dB per year, respectively, p<0.001), area of geographic loss defined by FAF (+2.5 mm2 and +3.7 mm2 per year, respectively, p<0.001) and thinning of the photoreceptor complex (up to -2.8 microns and -10.3 microns per year, p<0.001). CONCLUSION: Choroideremia carriers, particularly those with severe retinal phenotypes, exhibit progressive retinal degeneration, as evident by multimodal imaging biomarkers and functional testing. Clinicians should not rely on retinal severity classification alone to assess disease progression.

11.
Br J Ophthalmol ; 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39122354

RESUMO

PURPOSE: To compare the diagnostic utility of metagenomic deep sequencing (MDS) to cytology, flow cytometry and gene rearrangement by PCR in ocular samples of patients with suspected vitreoretinal lymphoma (VRL). METHODS: Patients with suspected VRL underwent ocular sampling of one or both eyes at the Emory Eye Center from September 2017 to June 2022. Ocular samples were evaluated with MDS and conventional diagnostics. MDS was performed at the Ralph and Sophie Heintz Laboratory at the F.I. Proctor Foundation. Relevant demographic and clinical data were retrospectively collected from medical records. Patients were diagnosed with VRL based on clinical assessment and conventional diagnostic testing. RESULTS: This study included 13 patients with suspected VRL who underwent diagnostic vitrectomy, including 1 patient who had an additional subretinal biopsy. Six patients (46.2%) were diagnosed with VRL. Among patients diagnosed with VRL, MDS detected pathogenic mutations in 5 out of 6 patients (83.3%) while cytology was positive for VRL in 4 out of 6 patients (66.7%), flow cytometry in 4 out of 4 patients (100.0%) and PCR in 4 out of 4 patients (100.0%). MDS detected mutations in MYD88 in 2 out of 6 patients diagnosed with VRL. In 7 patients (53.8%) not diagnosed with VRL, MDS detected pathogenic lymphoma mutations in 2 patients (28.6%). DISCUSSION: MDS detected pathogenic mutations in five out of six patients diagnosed with VRL, including in two patients with negative cytology, demonstrating its potential to improve diagnostic rates of VRL as an adjunctive test.

12.
Br J Ophthalmol ; 108(7): 1038-1043, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38164583

RESUMO

BACKGROUND/AIMS: Recent work has called into question the ability of visual acuity (VA) to accurately represent changes in visual function in infantile nystagmus (IN). This systematic review investigated factors affecting visual performance in IN, to guide development of suitable alternatives to VA. METHODS: Included studies used an experimental manipulation to assess changes in visual function in people with IN. Interventional studies, case series and case studies were excluded. Six databases were searched in August 2023. Selection, detection, attrition and measurement bias were assessed. Due to heterogeneous methodologies, narrative synthesis was undertaken. RESULTS: Eighteen relevant papers were identified, 11 of which complied with the review criteria. Articles were grouped according to the factor manipulated to evoke within-participant changes in performance (motion blur, psychological state, gaze angle or visual crowding). Optotype, image, grating and moving stimuli have been employed under varying lighting conditions and exposure duration. CONCLUSION: Several factors affecting visual performance should be considered when assessing visual function in IN. While maximum VA is a useful metric, its measurement deliberately minimises nystagmus-specific factors such as changes in visual performance with gaze angle and the 'slow to see' phenomenon. Maximum VA can be measured using the null zone, providing unlimited viewing time, reducing stress/mental load and minimising visual crowding. Gaze-dependent functional vision space is a promising measure which quantifies the impact of the null zone but does not consider temporal vision. Although no complete measurement technique has yet been proven, this review provides insights to guide future work towards development of appropriate methods.


Assuntos
Nistagmo Congênito , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Nistagmo Congênito/fisiopatologia , Movimentos Oculares/fisiologia
13.
Br J Ophthalmol ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38925907

RESUMO

The rapid advancements in generative artificial intelligence are set to significantly influence the medical sector, particularly ophthalmology. Generative adversarial networks and diffusion models enable the creation of synthetic images, aiding the development of deep learning models tailored for specific imaging tasks. Additionally, the advent of multimodal foundational models, capable of generating images, text and videos, presents a broad spectrum of applications within ophthalmology. These range from enhancing diagnostic accuracy to improving patient education and training healthcare professionals. Despite the promising potential, this area of technology is still in its infancy, and there are several challenges to be addressed, including data bias, safety concerns and the practical implementation of these technologies in clinical settings.

14.
BMJ Open Ophthalmol ; 9(1)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38830728

RESUMO

BACKGROUND: Unpreserved single-dose unit (SDU) eye drops are commonly used to avoid benzalkonium chloride-related toxicity. Although intended for single use, many patients report off-label repeated use of SDUs over a prolonged period. We investigated whether repeated use of dexamethasone 0.1% SDUs in the same patient increases the bacterial contamination rate. METHODS: We prospectively enrolled patients scheduled for inpatient corneal and glaucoma surgery receiving dexamethasone 0.1% SDU four times per day from the same vial. To assess contamination rates, one drop from the vial was cultured immediately after opening the SDU (t0), 10 hours later after four drop applications (t10) and 24 hours after opening without further drop applications (t24). Conjunctival swabs were taken before and after drop application. Contamination rate was assessed with a standard clinical culturing protocol without introducing a positive control. RESULTS: 110 eyes of 109 patients were evaluated. Drops collected immediately after opening the SDU (t0) were contaminated in 9/110 cultures (8.1%). At t10, 13/110 cultures were contaminated (11.8%; p=0.267) and 11/110 at t24 (10.0%; t24 vs t0; p=1.00). In 5 of 21 cases of contaminated drops at t10 and/or t24, the same isolates were cultured from the initial conjunctival swab and the SDU. In three cases, the same bacterial species was found in consecutive samples. CONCLUSION: The contamination rate of the SDU did not increase after multiple use within 24 hours. Contamination from fingertip flora was more likely than from ocular surface flora. Reuse of dexamethasone 0.1% SDU in the same patient within 24 hours appears to be safe.


Assuntos
Dexametasona , Glucocorticoides , Soluções Oftálmicas , Conservantes Farmacêuticos , Humanos , Dexametasona/administração & dosagem , Dexametasona/efeitos adversos , Soluções Oftálmicas/efeitos adversos , Masculino , Feminino , Estudos Prospectivos , Conservantes Farmacêuticos/efeitos adversos , Conservantes Farmacêuticos/administração & dosagem , Idoso , Pessoa de Meia-Idade , Glucocorticoides/administração & dosagem , Glucocorticoides/efeitos adversos , Idoso de 80 Anos ou mais , Adulto , Contaminação de Medicamentos , Glaucoma/tratamento farmacológico , Túnica Conjuntiva/microbiologia , Túnica Conjuntiva/efeitos dos fármacos , Bactérias/efeitos dos fármacos , Bactérias/isolamento & purificação , Doenças da Córnea/induzido quimicamente
15.
Br J Ophthalmol ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39009421

RESUMO

BACKGROUND: Tuberculosis (TB)-immunoreactivity, measured in vivo (tuberculin skin test (TST)) or in vitro (interferon gamma release assay (IGRA)), can be found in latent, active or even following clearance of TB infection. In this case-control study, we compared the systemic and ocular outcomes between patients with or without TB-immunoreactivity, who received immunomodulatory therapy (IMT) for non-infectious uveitis. METHODS: We retrospectively reviewed charts of patients with (cases) or without (controls) TB-immunoreactivity (TST±IGRA), who received conventional IMT for ≥6 months, for the treatment of non-infectious uveitis. Patients who received prior or concomitant anti-TB therapy were excluded. Systemic and ocular outcomes were compared between both groups. RESULTS: 36 cases and 70 controls (gender-matched and age-matched) were included. New-onset pulmonary or extrapulmonary TB developed in one case and none of the controls. Based on this outcome, the absolute risk increase for systemic TB reactivation was noted to be 0.028 (95% CI 0.005 to 0.051) and the number needed to harm was 36. The incidence of persistent or recurrent (worsening ≥2 grades) intraocular inflammation during IMT was comparable between both groups (cases 18/36, controls 35/70, p=1.0). A change in anatomical site of presentation at recurrence was not seen in any case, but in six controls (p=0.15). No new focal chorio-retinal lesions were noted in either group. CONCLUSIONS: Conventional IMT has a very low risk of systemic TB reactivation, and no additional detrimental effect on ocular outcomes, in TB-immunoreactive patients with non-infectious uveitis.

16.
Br J Ophthalmol ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38729765

RESUMO

BACKGROUND/AIMS: To evaluate the diagnostic accuracy of spectral-domain optical coherence tomography (SD OCT) combined with OCT angiography (OCTA) for myopic myopic macular neovascularisation (MNV) activity. METHODS: Both eyes of patients with myopic MNV diagnosed with fluorescein angiography (FA), SD OCT and OCTA were assessed by unmasked investigators. The images were deidentified and randomised before graded by masked investigators, who determined the presence of active myopic MNV by using SD OCT together with OCTA without FA and by FA alone, respectively. The findings of masked investigators were compared with unmasked investigators. RESULTS: 213 eyes of 110 patients comprising 499 imaging episodes were eligible for grading. For diagnosing new-onset myopic MNV without FA, combined use of SD OCT and OCTA had a sensitivity of 0.94, specificity of 0.84 and area under the curve (AUC) of 0.92. FA had a sensitivity of 0.52 (p<0.01), specificity of 0.80 (p=0.38) and AUC of 0.66 (p<0.01). For recurrent myopic MNV, the combination of SD OCT and OCTA had a sensitivity of 0.98, specificity of 0.78 and AUC of 0.88. FA had a sensitivity of 0.50 (p=0.04), specificity of 0.76 (p=0.85) and AUC of 0.63 (p=0.01). Myopic traction maculopathy was more frequently associated with recurrent myopic MNV (p<0.01). CONCLUSION: SD OCT with dense volumetric scan was highly sensitive for diagnosing myopic MNV. The addition of OCTA improved the diagnostic specificity without FA. Monitoring of the longitudinal changes on SD OCT and judicious use of FA is a reliable surveillance strategy for myopic MNV.

17.
Br J Ophthalmol ; 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-37923373

RESUMO

BACKGROUND/AIMS: The goal of health research is to improve patients care and outcomes. Thus, it is essential that research addresses questions that are important to patients and clinicians. The aim of this study was to develop a list of priorities for glaucoma research involving stakeholders from different countries in Europe. METHODS: We used a three-phase method, including a two-round electronic Delphi survey and a workshop. The clinician and patient electronic surveys were conducted in parallel and independently. For phase I, the survey was distributed to patients from 27 European countries in 6 different languages, and to European Glaucoma Society members, ophthalmologists with expertise in glaucoma care, asking to name up to five research priorities. During phase II, participants were asked to rank the questions identified in phase I using a Likert scale. Phase III was a 1 day workshop with patients and clinicians. The purpose was to make decisions about the 10 most important research priorities using the top 20 priorities identified by patients and clinicians. RESULTS: In phase I, 308 patients and 150 clinicians were involved. In phase II, the highest-ranking priority for both patients and clinicians was 'treatments to restore vision'. In phase III, eight patients and four clinicians were involved. The top three priorities were 'treatments to stop sight loss', 'treatments to restore vision' and 'improved detection of worsening glaucoma'. CONCLUSION: We have developed a list of priorities for glaucoma research involving clinicians and patients from different European countries that will help guide research efforts and investment.

18.
BMJ Open Ophthalmol ; 9(1)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388003

RESUMO

PURPOSE: To prove the safety and performance of the hypothermic corneal storage medium "Corneal Chamber" and the rinsing solution "PSS-L" in support of the new Conformité Européenne (CE) certification process in accordance with the Medical Device Regulation. METHODS: Fifteen (n=15) human donor corneas and 11 (n=11) porcine corneas were evaluated for the following parameters: endothelial cell density (ECD) and mortality, percentage of hexagonal cells (HEX%), coefficient of cellular area variation (CV%) and corneal transparency at Day 0 and after 14±1 days of storage in Corneal Chamber medium at 2-8°C. Then, the same parameters were assessed after rinsing of corneas in PSS-L for 1 min at room temperature. Evaluation of gentamicin sulfate carryover after corneal storage and PSS-L rinsing was performed by ultra-high performance liquid chromatography analysis on human corneas homogenates. RESULTS: Human and porcine corneas stored in Corneal Chamber medium showed a good overall quality of the tissue according to the quality parameters evaluated. In particular, mean ECD, HEX% and CV% did not show statistically significant changes at the end of storage and endothelial mortality increased to 3.1±3.3 and 7.8±3.5% in human and porcine corneas, respectively. Tissue rinsing with PSS-L did not affect the quality parameters evaluated before and gentamicin sulfate residues were absent in human corneas. CONCLUSIONS: Corneal preservation in Corneal Chamber medium at 2-8°C for 14 days and the corneal rinse with PSS-L are safe and effective procedures allowing the preservation of the corneal quality parameters as well as the complete elimination of gentamicin sulfate from the tissues before transplantation.Cite Now.


Assuntos
Transplante de Córnea , Endotélio Corneano , Humanos , Suínos , Animais , Córnea , Preservação de Órgãos/métodos , Transplante de Córnea/métodos , Gentamicinas/farmacologia
19.
Br J Ophthalmol ; 107(7): 1018-1024, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35241443

RESUMO

PURPOSE: To compare mydriatic and eye-steering ultrawide field imaging (UWFI) with standard non-mydriatic UWFI examination in detecting peripheral retinal lesions in myopic patients. METHODS: Cross-sectional, observational study. 220 eyes of 110 myopic patients with known peripheral retinal lesions in at least one eye under Goldmann three mirror contact lens examination were recruited. Non-mydriatic standard and eye-steering UWFI images were taken centrally and with eye-steering technique in upper, lower, nasal and temporal gazes under Optomap UWFI (Daytona, Optos, UK). Mydriatic standard and eye-steering UWFI was captured in central gaze and four different peripheral gazes. Sensitivity of detecting peripheral retinal lesions under different UWFI settings was compared. RESULTS: 141 (64.09%) eyes were with peripheral retinal lesions. The sensitivity for detecting peripheral lesions from low to high was 41.84% (95% CI 33.62% to 50.54%) under non-mydriatic standard UWFI setting, 52.48% (95% CI 44.08% to 60.75%) under mydriatic standard setting, 75.18% (95% CI 67.21% to 82.06%) under non-mydriatic eye-steering setting and 86.52% (95% CI 79.76% to 91.69%) under mydriatic eye-steering setting. Both mydriasis and eye-steering technique increased sensitivity of detecting peripheral lesions with statistical significance (p<0.001). By applying eye-steering technique, sensitivity of detecting lesions located in superior and inferior quadrants witnessed a greater increase compared with other two quadrants (p<0.05). Neither spherical equivalence (p>0.05) nor axial length (p>0.05) was an independent influence factor for detecting peripheral lesions. CONCLUSIONS: Eye-steering technique and mydriasis could both efficiently improve the sensitivity of detecting peripheral retinal lesions in myopic patients. Lesions of superior and inferior quadrants benefited more from eye-steering technique.


Assuntos
Midríase , Miopia , Humanos , Estudos Transversais , Midriáticos , Olho , Diagnóstico por Imagem , Miopia/diagnóstico
20.
Br J Ophthalmol ; 107(8): 1144-1150, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-35354561

RESUMO

BACKGROUND/AIMS: To further validate the Vision Impairment in Low Luminance (VILL) questionnaire, which captures visual functioning and vision-related quality of life (VRQoL) under low luminance, low-contrast conditions relevant to age-related macular degeneration (AMD). METHODS: The VILL was translated from German into English (UK), Danish, Dutch, French, Italian and Portuguese. Rasch analysis was used to assess psychometric characteristics of 716 participants (65% female, mean age 72±7 years, 82% intermediate AMD) from the baseline visit of the MACUSTAR study. In a subset of participants (n=301), test-retest reliability (intraclass correlation coefficient (ICC) and coefficient of repeatability (CoR)) and construct validity were assessed. RESULTS: Four items were removed from the VILL with 37 items due to misfit. The resulting Vision Impairment in Low Luminance with 33 items (VILL-33) has three subscales with no disordered thresholds and no misfitting items. No differential item functioning and no multidimensionality were observed. Person reliability and person separation index were 0.91 and 3.27 for the Vision Impairment in Low Luminance Reading Subscale (VILL-R), 0.87 and 2.58 for the Vision Impairment in Low Luminance Mobility Subscale (VILL-M), and 0.78 and 1.90 for the Vision Impairment in Low Luminance Emotional Subscale (VILL-E). ICC and CoR were 0.92 and 1.9 for VILL-R, 0.93 and 1.8 for VILL-M and 0.82 and 5.0 for VILL-E. Reported VRQoL decreased with advanced AMD stage (p<0.0001) and was lower in the intermediate AMD group than in the no AMD group (p≤0.0053). CONCLUSION: The VILL is a psychometrically sound patient-reported outcome instrument, and the results further support its reliability and validity across all AMD stages. We recommend the shortened version of the questionnaire with three subscales (VILL-33) for future use. TRIAL REGISTRATION NUMBER: NCT03349801.


Assuntos
Degeneração Macular , Baixa Visão , Idoso , Feminino , Humanos , Masculino , Degeneração Macular/complicações , Degeneração Macular/diagnóstico , Psicometria/métodos , Qualidade de Vida/psicologia , Reprodutibilidade dos Testes , Inquéritos e Questionários , Visão Ocular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa