Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(13)2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34206437

RESUMO

Capacitive sensors are widely used in industrial applications, such as CNC machine tools, where reliable positioning in the micrometer range with nanometer accuracy is required. Hence, these sensors are operated in harsh industrial environments. The accuracy of these sensors is mainly limited by slope errors and nonlinearities. In practice, the required accuracy of these sensors is achieved by a calibration against a metrological high-quality reference such as interferometric displacement measurement systems. This usually involves the use of high-order polynomials as calibration functions based on empirical data. In metrology, this is only the second-best approach and has disadvantages in terms of stability over the measurement range of the instrument. In addition, the validity of these empirical calibrations over time is questionable, and the associated uncertainty can only be roughly estimated. This makes regular recalibration of such sensors at short intervals mandatory to ensure the reliability of the displacement measurement. In this paper, we report on our investigations of the different parameters that affect the accuracy of capacitive sensors. Since the capacitance of these sensors results from the electric fields that build up between the electrodes, these field lines are calculated using FEM simulation models for typical commercial sensors. In the following the influence of various geometric parameters such as edge radius, guard ring size and shape, or thickness of the electrodes are individually analyzed according to their impact on the accuracy of these sensors. Based on these simulations, the deviations of the capacitance as they arise for real detector geometries can then be compared with idealized, de facto unrealizable parallel plate capacitors. This methodology allows overall uncertainty of capacitive sensors to be decomposed into their individual components and sorted in terms of their contribution to the uncertainty budget. The individual FEM-based analysis then enables a systematic analysis of the sources of uncertainty and, thus, reveals possibilities to improve manufacturing processes for capacitive sensors, to put these sensors on a solid metrological basis, and to improve the performance of these displacement measurement systems in the long run, i.e., to provide better sensors for the application.

2.
Sensors (Basel) ; 19(9)2019 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-31086090

RESUMO

The inductive proximity sensor (IPS) is applicable to displacement measurements in the aviation field due to its non-mechanical contact, safety, and durability. IPS can increase reliability of position detection and decrease maintenance cost of the system effectively in aircraft applications. Nevertheless, the specialty in the aviation field proposes many restrictions and requirements on the application of IPS, including the temperature drift effect of the resistance component of the IPS sensing coil. Moreover, reliability requirements of aircrafts restrict the use of computational-intensive algorithms and avoid the use of process control components. Furthermore, the environment of airborne electronic equipment restricts measurements driven by large current and proposes strict requirements on emission tests of radio frequency (RF) energy. For these reasons, a differential structured IPS measurement method is proposed in this paper. This measurement method inherits the numerical separation of the resistance and inductance components of the IPS sensing coil to improve the temperature adaptation of the IPS. The computational complexity is decreased by combining the dimension-reduced look-up table method to prevent the use of process control components. The proposed differential structured IPS is equipped with a differential structure of distant and nearby sensing coils to increase the detection accuracy. The small electric current pulse excitation decreases the RF energy emission. Verification results demonstrate that the differential structured IPS realizes the numerical decoupling calculation of the vector impedance of the sensing coil by using 61 look-up table units. The measuring sensitivity increased from 135.5 least significant bits (LSB)/0.10 mm of a single-sensing-coil structured IPS to 1201.4 LSB/0.10 mm, and the linear approximation distance error decreased from 99.376 µm to -3.240 µm. The proposed differential structured IPS method has evident comparative advantages compared with similar measuring techniques.

3.
J Mol Biol ; 436(4): 168420, 2024 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-38143021

RESUMO

The width of the periplasmic space of Gram-negative bacteria is only about 25-30 nm along the long axis of the cell, which affects free diffusion of (macro)molecules. We have performed single-particle displacement measurements and diffusion simulation studies to determine the impact of confinement on the apparent mobility of proteins in the periplasm of Escherichia coli. The diffusion of a reporter protein and of OsmY, an osmotically regulated periplasmic protein, is characterized by a fast and slow component regardless of the osmotic conditions. The diffusion coefficient of the fast fraction increases upon osmotic upshift, in agreement with a decrease in macromolecular crowding of the periplasm, but the mobility of the slow (immobile) fraction is not affected by the osmotic stress. We observe that the confinement created by the inner and outer membranes results in a lower apparent diffusion coefficient, but this can only partially explain the slow component of diffusion in the particle displacement measurements, suggesting that a fraction of the proteins is hindered in its mobility by large periplasmic structures. Using particle-based simulations, we have determined the confinement effect on the apparent diffusion coefficient of the particles for geometries akin the periplasmic space of Gram-negative bacteria.


Assuntos
Proteínas de Escherichia coli , Escherichia coli , Periplasma , Difusão , Escherichia coli/química , Proteínas de Escherichia coli/química , Pressão Osmótica , Periplasma/química , Imagem Individual de Molécula
4.
Clin Implant Dent Relat Res ; 26(2): 327-332, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37926940

RESUMO

BACKGROUND: The influence of dental implant length and diameter on primary stability in various bone densities is not well understood. AIM: To in vitro study the effect of length and diameter on resonance frequency analysis (RFA), insertion torque (IT) and displacement (DP) measurements of dental implants in different implant site densities. MATERIALS AND METHODS: Dental implants of four different diameters (Ø 3.5, 4.0, 4.5 and 5.0 mm) and three different lengths (7, 11 and 15 mm) (Neoss Ltd, Harrogate, UK) were placed in polyurethane blocks of three different densities (Sawbones Europe AB, Malmö, Sweden). The primary stability was assessed by RFA (ISQ) (Osstell, Osstell AB, Gothenburg, Sweden) and insertion torque measurements (ITmax in N cm) (iChiropo™, Bien-Air Dental SA, Bienne, Switzerland). In addition, the blocks were mounted in a rig and a lateral force of 25 N cm was applied to the implants and the DP was measured in µm with a micrometer gauge placed on the opposite side of the load transducer. Statistical analyses using linear and quadratic models were applied. RESULTS: Implant length, diameter and block density were found to be significant independent predictors of RFA, ITmax, and DP measurements. Implant length had a strong effect, while the effect of diameter in general was subtle, particularly in the softest block. CONCLUSIONS: Implant length affects primary stability more than implant diameter in polyurethane blocks of uniform density along the whole length of the tested implants.


Assuntos
Implantes Dentários , Implantação Dentária Endóssea , Poliuretanos , Vibração , Retenção em Prótese Dentária , Densidade Óssea , Torque
5.
Opt Eng ; 52(10): 101916, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-24790255

RESUMO

Acoustically-induced vibrations of the Tympanic Membrane (TM) play a primary role in the hearing process, in that these motions are the initial mechanical response of the ear to airborne sound. Characterization of the shape and 3D displacement patterns of the TM is a crucial step to a better understanding of the complicated mechanics of sound reception by the ear. In this paper, shape and sound-induced 3D displacements of the TM in cadaveric chinchillas are measured by a lensless Dual-Wavelength Digital Holography system (DWDHS). The DWDHS consists of Laser Delivery (LD), Optical Head (OH), and Computing Platform (CP) subsystems. Shape measurements are performed in double-exposure mode and with the use of two wavelengths of a tunable laser while nanometer-scale displacements are measured along a single sensitivity direction and with a constant wavelength. In order to extract the three principal components of displacement in full-field-of-view, and taking into consideration the anatomical dimensions of the TM, we combine principles of thin-shell theory together with both, displacement measurements along the single sensitivity vector and TM surface shape. To computationally test this approach, Finite Element Methods (FEM) are applied to the study of artificial geometries.

6.
Sensors (Basel) ; 8(12): 8139-8155, 2008 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-27873980

RESUMO

During construction of the Sentvid tunnel a unique opportunity arose to measure the 3D displacements ahead of the motorway tunnel excavation face, since the exploratory tunnel was already constructed in the axis of the main tunnel. According to reviewed literature such measurements had not been performed yet and several problems regarding equipment and complete scheme of the experiment needed to be overcome. The paper gives a brief description of the Sentvid tunnel project, presents significant factors that affected the choice of the geodetic equipment and describes the scheme of the experiment. A special attention is focused on the problems relating to the operation of the instrument in demanding environmental conditions (water, dust).

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa