Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Microsc ; 294(3): 319-337, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38683038

RESUMO

Developing devices and instrumentation in a bioimaging core facility is an important part of the innovation mandate inherent in the core facility model but is a complex area due to the required skills and investments, and the impossibility of a universally applicable model. Here, we seek to define technological innovation in microscopy and situate it within the wider core facility innovation portfolio, highlighting how strategic development can accelerate access to innovative imaging modalities and increase service range, and thus maintain the cutting edge needed for sustainability. We consider technology development from the perspective of core facility staff and their stakeholders as well as their research environment and aim to present a practical guide to the 'Why, When, and How' of developing and integrating innovative technology in the core facility portfolio. Core facilities need to innovate to stay up to date. However, how to carry out the innovation is not very obvious. One area of innovation in imaging core facilities is the building of optical setups. However, the creation of optical setups requires specific skill sets, time, and investments. Consequently, the topic of whether a core facility should develop optical devices is discussed as controversial. Here, we provide resources that should help get into this topic, and we discuss different options when and how it makes sense to build optical devices in core facilities. We discuss various aspects, including consequences for staff and the relation of the core to the institute, and also broaden the scope toward other areas of innovation.


Assuntos
Invenções , Microscopia/métodos , Microscopia/instrumentação
2.
Acta Oncol ; 62(11): 1566-1573, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37603112

RESUMO

BACKGROUND: The purpose of this study was to introduce an experimental radiobiological setup used for in vivo irradiation of a mouse leg target in multiple positions along a proton beam path to investigate normal tissue- and tumor models with varying linear energy transfer (LET). We describe the dosimetric characterizations and an acute- and late-effect assay for normal tissue damage. METHODS: The experimental setup consists of a water phantom that allows the right hind leg of three to five mice to be irradiated at the same time. Absolute dosimetry using a thimble (Semiflex) and a plane parallel (Advanced Markus) ionization chamber and Monte Carlo simulations using Geant4 and SHIELD-HIT12A were applied for dosimetric validation of positioning along the spread-out Bragg peak (SOBP) and at the distal edge and dose fall-off. The mice were irradiated in the center of the SOBP delivered by a pencil beam scanning system. The SOBP was 2.8 cm wide, centered at 6.9 cm depth, with planned physical single doses from 22 to 46 Gy. The biological endpoint was acute skin damage and radiation-induced late damage (RILD) assessed in the mouse leg. RESULTS: The dose-response curves illustrate the percentage of mice exhibiting acute skin damage, and at a later point, RILD as a function of physical doses (Gy). Each dose-response curve represents a specific severity score of each assay, demonstrating a higher ED50 (50% responders) as the score increases. Moreover, the results reveal the reversible nature of acute skin damage as a function of time and the irreversible nature of RILD as time progresses. CONCLUSIONS: We want to encourage researchers to report all experimental details of their radiobiological setups, including experimental protocols and model descriptions, to facilitate transparency and reproducibility. Based on this study, more experiments are being performed to explore all possibilities this radiobiological experimental setup permits.


Assuntos
Terapia com Prótons , Prótons , Animais , Camundongos , Reprodutibilidade dos Testes , Terapia com Prótons/métodos , Radiometria/métodos , Modelos Teóricos , Método de Monte Carlo
3.
NMR Biomed ; 35(1): e4620, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34585794

RESUMO

T1 and T2 relaxation times combined with 31 P spectroscopy have been proven efficient for muscular disease characterization as well as for pre- and post-muscle stimulation measurements. Even though 31 P spectroscopy can already be performed during muscle exercise, no method for T1 and T2 measurement enables this possibility. In this project, a complete setup and protocol for multi-parametrical MRI of the rat gastrocnemius before, during and after muscle stimulation at 4.7 and 7 T is presented. The setup is fully MRI compatible and is composed of a cradle, an electro-stimulator and an electronic card in order to synchronize MRI sequences with muscle stimulation. A 2D triggered radial-encoded Look-Locker sequence was developed, and enabled T1 measurements in less than 2 min on stimulated muscle. Also, a multi-slice multi-echo sequence was adapted and synchronized for T2 measurements as well as 31 P spectroscopy acquisitions in less than 4 min in both cases on stimulated muscle. Methods were validated on young rats using different stimulation paradigms. Then they were applied on older rats to compare quantification results, using the different stimulation paradigms, and allowed observation of metabolic changes related to aging with good reproducibility. The robustness of the whole setup shows wide application opportunities.


Assuntos
Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Fatores Etários , Animais , Estimulação Elétrica , Feminino , Músculo Esquelético/fisiologia , Imagens de Fantasmas , Ratos , Ratos Wistar
4.
Clin Oral Investig ; 26(9): 5687-5696, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35536440

RESUMO

OBJECTIVES: SOPs recommend high-volume evacuation (HVE) for aerosol-generating procedures (AGPs) in dentistry. Therefore, in the exploratory study, the area of splatter contamination (SCON in %) generated by high-speed tooth preparation (HSP) and air-polishing (APD) was measured when different suction cannulas of 6 mm diameter (saliva ejector (SAE)), 11 mm (HC11), or 16 mm (HC16) were utilized versus no-suction (NS). MATERIALS AND METHODS: Eighty tests were performed in a closed darkened room to measure SCON (1m circular around the manikin head (3.14 m2) via plan metrically assessment through fluorescence technique. HSP (handpiece, turbine (Kavo, Germany)) or APD (LM-ProPowerTM (Finland), Airflow®-Prophylaxis-Master (Switzerland)) for 6 min plus 5 s post-treatment were performed either without suction or with low-flow (150 l/min for SAE) or high-flow rate (250 l/min/350 l/min for HC11/HC16) suction. All tests were two-tailed (p≤0.05, Bonferroni corrected for multi-testing). RESULTS: Irrespective the AGP, SCON was higher for NS (median [25th; 75th percentiles]: 3.4% [2.6; 5.4]) versus high-flow suction (1.9% [1.5; 2.5]) (p=0.002). Low-flow suction (3.5% [2.6; 4.3]) versus NS resulted in slightly lower but not statistically significantly lower SCON (p=1.000) and was less effective than high-flow suction (p=0.003). Lowest contamination values were found with HC16 (1.9% [1.5; 2.5]; p≤0.002), whereat no significant differences were found for HC11 (2.4% [1.7; 3.1]) compared to SAE (p=0.385) or NS (p=0.316). CONCLUSIONS: Within study's limitations, the lowest splatter contamination values resulted when HC16 were utilized by a high-flow rate of ≥250 l/min. CLINICAL RELEVANCE: It is strongly recommended to utilize an HVE with suction cannulas of 16mm diameter for a high-flow rate during all AGPs and afterwards also to disinfect all surface of patients or operators contacted.


Assuntos
Cânula , Odontologia , Sucção , Preparo do Dente , Aerossóis , Finlândia , Humanos , Sucção/instrumentação
5.
Sensors (Basel) ; 22(3)2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35161871

RESUMO

The article presents the possibilities of using fiber-optic acceleration (FOC) sensors on products of rocket-space and aviation technology as part of information-measuring systems. A special measuring device has been developed for experimental confirmation of the main characteristics of the technical characteristics of the developed, two-coordinate fiber-optic acceleration sensors. The developed measuring setup for the experimental research of a two-coordinate fiber-optic acceleration sensor with two, cylindrical lenses fixed on two H-shaped elastic elements deflected under the influence of acceleration in two mutually perpendicular directions X and Y, intended for operation in harsh conditions of rocket and space technology. The experimental equipment consists of the developed setup for setting micromovements and an information conversion unit, including modules for signal conversion, transmission, power supply, signal amplification, and indication. Experimental dependences of the output voltage from the information conversion unit's output on the micro-displacement in the range corresponding to the micro-displacements of the inertial mass with a cylindrical lens under acceleration in the range of ±100 m/s2 were obtained on the micro-displacement setting unit. The maximum value of the linearity error of the prototype acceleration sensor together with the information conversion unit was 0.07%. The conversion sensitivity of a two-coordinate fiber-optic acceleration sensor per the experimental dependences obtained on the Data Physics LE-612 MST/DSA 10-40 k vibration stand when exposed to sinusoidal vibration with an acceleration amplitude from 2 to 10 g in the frequency range from 5 to 2560 Hz was, on average, 3 mV/m/s2. The conducted experimental research confirms the performance of experimental samples of fiber-optic acceleration sensors together with an information conversion unit, as well as the achievement of high metrological characteristics.

6.
Surg Endosc ; 34(2): 787-795, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31114950

RESUMO

BACKGROUND: During laparoscopic operations, the trocars are often out of the viewing field of the laparoscope. Blind insertion of laparoscopic instruments is potentially dangerous especially when they are pointed or hot. A guidance of the instrument to the target point has the potential to improve the safety of instrument insertion. METHODS: In this study, the effect of a mechanical and an optical tool for guided instrument insertion into the abdominal cave was evaluated. The controlled prospective randomized study measured safety and efficiency of instrument insertion by 60 novices in an inanimate standardized box trainer. A post-test questionnaire based on the NASA Task Load Index prompted for the subjective impressions of the subjects. RESULTS: Instrument insertion with optical guidance showed a shorter (p = 0.002) insertion time (median 87.5 s for nine insertions) compared with blind insertion (median 112.0 s for nine insertions). The error number with optical guidance (median 0.5) was lower (p = 0.064) compared with blind insertion (median 1.0). The mechanical guidance showed a shorter (p = 0.001) insertion time (median 89.0 s for nine insertions) and less (p = 0.044) touch errors (median 0) compared with blind insertion. The results of the two guidance tools (mechanical vs. optical guidance) showed no significant difference. In the questionnaire, 89% of the novices subjectively judged the mechanical guidance tool better than blind insertion. The assessments of optical compared to mechanical guidance turned out quite similar. CONCLUSIONS: In the experimental setup, instrument insertion with a guidance tool performed faster and safer compared with blind insertion. The subjective assessments confirmed the benefit of instrument guidance.


Assuntos
Competência Clínica , Laparoscopia/educação , Instrumentos Cirúrgicos , Cirurgia Vídeoassistida , Adulto , Colecistectomia/educação , Colecistectomia/métodos , Feminino , Humanos , Laparoscopia/métodos , Masculino , Estudos Prospectivos , Inquéritos e Questionários
7.
Med J Armed Forces India ; 75(4): 415-423, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31719736

RESUMO

BACKGROUND: Torque is an important component of preadjusted edgewise prescriptions to achieve ideal/optimum tooth position and more so in aesthetics sensitive maxillary anterior teeth. Thus, the need to audit available commercial brands of 018Roth and 022MBT was felt and in vitro analysis of eight brands namely 3M Unitek, Dentaurum, d-tech, IMD Medical, Libral Leone, Modern Orthodontics, Ormco and Ortho Organizer, was carried out. METHODS: The method involved perfect superimposition of two standardized images: one delineating facial axis of the tooth with stainless steel straight wire and other with full dimension arch wire engagement in bracket. The two images were superimposed and opacity of one of the images altered using Adobe Photoshop software to reveal the position of two wires. The angle obtained between two wires gave a direct read-out of torque expression. The comparison was statistically done with one-way ANOVA and Tukey's HSD test. RESULTS: In 018Roth group, IMD Medical did not show any significant difference from the standard while comparison independent of standard showed that IMD, Modern Orthodontics and Ormco were not significantly different from each other. In 022MBT group, IMD Medical, d-tech, 3M Unitek and Modern Orthodontics did not have statistically significant difference from and independent of standard. CONCLUSION: Significant variations from the standard values of both 018 Roth and 022 MBT exist in the market products and thus selection of product must be based on proper guidance in addition to clinical acumen/experience. Also the methodology provides easy to use, inexpensive set-up in the clinical settings.

8.
Surg Innov ; 25(5): 515-524, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30028243

RESUMO

BACKGROUND: To regain 2-eyed vision in laparoscopy, dual-channeled optics have been introduced. With this optics design, the distance between the 2 front lenses defines how much stereoscopic effect is seen. This study quantifies the impact of an enhanced and a reduced stereo effect on surgical task efficiency. METHODS: A prospective single-blinded study was performed with 20 laparoscopic novices in an inanimate experimental setting. A standard bichannelled stereo system was used to perform a suturing and knotting task. The working distance and the task size were scaled to vary the stereo effect and, thereby, simulate hypothetic stereo optics with enhanced and reduced optical bases. The task performances were timed, and the number of trials for stitching out was counted. The participants finally filled out a questionnaire to collect subjective impressions. RESULTS: The increase of the stereo effect by 50% caused no objective improvement in laparoscopic knotting compared with typical 3D (control group with stereo basis of 4.5 mm). But ergonomic disadvantages (headache) were subjectively reported in 1 of 20 cases in the questionnaire. The reduction of the stereo effect by one-third led to a significantly longer average execution time. There was no significant dependence found between stereo effect and number of stich-out trials, stitching precision, or knotting quality. CONCLUSIONS: Considering laparoscopy, it does not seem advisable to enhance the stereo effect because of ergonomic problems. Otherwise, a miniaturization of the 3D scope (5 mm version) is problematic because its benefit mostly shrinks with the reduced stereo effect.


Assuntos
Laparoscopia , Eficiência , Ergonomia , Feminino , Humanos , Laparoscopia/métodos , Laparoscopia/normas , Laparoscopia/estatística & dados numéricos , Masculino , Imagens de Fantasmas , Estudos Prospectivos , Distribuição Aleatória , Estudantes de Medicina , Inquéritos e Questionários , Técnicas de Sutura , Análise e Desempenho de Tarefas
9.
Behav Res Methods ; 49(3): 822-834, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27287446

RESUMO

Today, capturing the behavior of a human eye is considered a standard method for measuring the information-gathering process and thereby gaining insights into cognitive processes. Due to the dynamic character of most task environments there is still a lack of a structured and automated approach for analyzing eye movement in combination with moving objects. In this article, we present a guideline for advanced gaze analysis, called IGDAI (Integration Guideline for Dynamic Areas of Interest). The application of IGDAI allows gathering dynamic areas of interest and simplifies its combination with eye movement. The first step of IGDAI defines the basic requirements for the experimental setup including the embedding of an eye tracker. The second step covers the issue of storing the information of task environments for the dynamic AOI analysis. Implementation examples in XML are presented fulfilling the requirements for most dynamic task environments. The last step includes algorithms to combine the captured eye movement and the dynamic areas of interest. A verification study was conducted, presenting an air traffic controller environment to participants. The participants had to distinguish between different types of dynamic objects. The results show that in comparison to static areas of interest, IGDAI allows a faster and more detailed view on the distribution of eye movement.


Assuntos
Aeronaves , Algoritmos , Movimentos Oculares , Projetos de Pesquisa/normas , Humanos
10.
BMC Genomics ; 17: 228, 2016 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-26969675

RESUMO

BACKGROUND: Inference of gene regulation from expression data may help to unravel regulatory mechanisms involved in complex diseases or in the action of specific drugs. A challenging task for many researchers working in the field of systems biology is to build up an experiment with a limited budget and produce a dataset suitable to reconstruct putative regulatory modules worth of biological validation. RESULTS: Here, we focus on small-scale gene expression screens and we introduce a novel experimental set-up and a customized method of analysis to make inference on regulatory modules starting from genetic perturbation data, e.g. knockdown and overexpression data. To illustrate the utility of our strategy, it was applied to produce and analyze a dataset of quantitative real-time RT-PCR data, in which interferon-α (IFN-α) transcriptional response in endothelial cells is investigated by RNA silencing of two candidate IFN-α modulators, STAT1 and IFIH1. A putative regulatory module was reconstructed by our method, revealing an intriguing feed-forward loop, in which STAT1 regulates IFIH1 and they both negatively regulate IFNAR1. STAT1 regulation on IFNAR1 was object of experimental validation at the protein level. CONCLUSIONS: Detailed description of the experimental set-up and of the analysis procedure is reported, with the intent to be of inspiration for other scientists who want to realize similar experiments to reconstruct gene regulatory modules starting from perturbations of possible regulators. Application of our approach to the study of IFN-α transcriptional response modulators in endothelial cells has led to many interesting novel findings and new biological hypotheses worth of validation.


Assuntos
Redes Reguladoras de Genes , Interferon-alfa/genética , Interferência de RNA , RNA Helicases DEAD-box/genética , Regulação da Expressão Gênica , Técnicas de Silenciamento de Genes , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Helicase IFIH1 Induzida por Interferon , Modelos Genéticos , Receptor de Interferon alfa e beta/genética , Fator de Transcrição STAT1/genética
11.
Mar Pollut Bull ; 201: 116254, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484536

RESUMO

This study conducts experimental and numerical simulations and analyzes the effects of the air bubble barrier (ABB) on the oil spill spread prevention efficiency regarding the varying aperture diameter, air discharge, and pollutant type. In a computational fluid dynamics simulation, a multiphase flow is studied using the finite volume method with the volume of fluid technique in the Star CCM+ software. The pipe generating air bubbles is fixed at the bottom of the tank at 1.8 m from the side of the experimental setup. The distinctive points of the study are the experiments conducted on different pollutants and the utilization of a novel adjustable air nozzle positioned on the air feed pipe. The effectiveness of the ABB in mitigating the spread of marine pollution is contingent on the aperture size, air discharge, and pollutant type. This study demonstrates that the ABB's feasibility for preventing the oil spill spread has improved.


Assuntos
Poluentes Ambientais , Poluição por Petróleo , Poluentes Químicos da Água , Poluição por Petróleo/prevenção & controle , Simulação por Computador , Software , Poluentes Químicos da Água/análise
12.
Biotechnol Bioeng ; 110(10): 2633-42, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23568808

RESUMO

In cell culture process development, monitoring and analyzing metabolic key parameters is routinely applied to demonstrate specific advantages of one experimental setup over another. It is of great importance that the observed differences and expected improvements are practically relevant and statistically significant. However, a systematic assessment whether observed differences in metabolic rates are statistically significant or not is often missing. This can lead to time-consuming and costly changes of an established biotechnological process due to false positive results. In the present work we demonstrate how well-established statistical tools can be employed to analyze systematically different sources of variations in metabolic rate determinations and to assess, in an unbiased way, their implications on the significance of the observed differences. As a case study, we evaluate differing growth characteristics and metabolic rates of the avian designer cell line AGE1.CR.pIX cultivated in a stirred tank reactor and in a wave bioreactor. Although large differences in metabolic rates and cell growth were expected (due to different aeration, agitation, pH-control, etc.) and partially observed (up to 79%), our results show that the inter-experimental variance between experiments performed under identical conditions but with different pre-cultures is a major contributor to the overall variance of metabolic rates. The lower bounds of the overall relative standard deviations for specific metabolic rates were between 4% and 73%. The application of available statistical methods revealed that the observed differences were statistically not significant and consequently insufficient to confirm relevant differences between both cultivation systems. Our study provides a general guideline for statistical analyses in comparative cultivation studies and emphasizes the necessity to account for the inter-experimental variance (mainly caused by biological variation) to avoid false-positive results.


Assuntos
Técnicas de Cultura de Células/métodos , Metabolismo/fisiologia , Modelos Biológicos , Modelos Estatísticos , Animais , Reatores Biológicos , Linhagem Celular , Meios de Cultura/metabolismo , Patos , Espaço Extracelular/metabolismo , Biologia de Sistemas
13.
Int J Pharm X ; 6: 100220, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38146325

RESUMO

This study aimed to evaluate and better understand the potential impact that a layer of surrounding hydrogel (mimicking living tissue) can have on the drug release from PLGA microparticles. Ibuprofen-loaded microparticles were prepared with an emulsion solvent extraction/evaporation method. The drug loading was about 48%. The surface of the microparticles appeared initially smooth and non-porous. In contrast, the internal microstructure of the particles exhibited a continuous network of tiny pores. Ibuprofen release from single microparticles was measured into agarose gels and well-agitated phosphate buffer pH 7.4. Optical microscopy, scanning electron microscopy, differential scanning calorimetry, X-ray powder diffraction, and X-ray µCT imaging were used to characterize the microparticles before and after exposure to the release media. Importantly, ibuprofen release was much slower in the presence of a surrounding agarose gel, e.g., the complete release took two weeks vs. a few days in well agitated phosphate buffer. This can probably be attributed to the fact that the hydrogel sterically hinders substantial system swelling and, thus, slows down the related increase in drug mobility. In addition, in this particular case, the convective flow in agitated bulk fluid likely damages the thin PLGA layer at the microparticles' surface, giving the outer aqueous phase more rapid access to the inner continuous pore network: Upon contact with water, the drug dissolves and rapidly diffuses out through a continuous network of water-filled channels. Without direct surface access, most of the drug "has to wait" for the onset of substantial system swelling to be released.

14.
Front Hum Neurosci ; 17: 1305331, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38125713

RESUMO

A novel multimodal experimental setup and dyadic study protocol were designed to investigate the neurophysiological underpinnings of joint action through the synchronous acquisition of EEG, ECG, EMG, respiration and kinematic data from two individuals engaged in ecologic and naturalistic cooperative and competitive joint actions involving face-to-face real-time and real-space coordinated full body movements. Such studies are still missing because of difficulties encountered in recording reliable neurophysiological signals during gross body movements, in synchronizing multiple devices, and in defining suitable study protocols. The multimodal experimental setup includes the synchronous recording of EEG, ECG, EMG, respiration and kinematic signals of both individuals via two EEG amplifiers and a motion capture system that are synchronized via a single-board microcomputer and custom Python scripts. EEG is recorded using new dry sports electrode caps. The novel study protocol is designed to best exploit the multimodal data acquisitions. Table tennis is the dyadic motor task: it allows naturalistic and face-to-face interpersonal interactions, free in-time and in-space full body movement coordination, cooperative and competitive joint actions, and two task difficulty levels to mimic changing external conditions. Recording conditions-including minimum table tennis rally duration, sampling rate of kinematic data, total duration of neurophysiological recordings-were defined according to the requirements of a multilevel analytical approach including a neural level (hyperbrain functional connectivity, Graph Theoretical measures and Microstate analysis), a cognitive-behavioral level (integrated analysis of neural and kinematic data), and a social level (extending Network Physiology to neurophysiological data recorded from two interacting individuals). Four practical tests for table tennis skills were defined to select the study population, permitting to skill-match the dyad members and to form two groups of higher and lower skilled dyads to explore the influence of skill level on joint action performance. Psychometric instruments are included to assess personality traits and support interpretation of results. Studying joint action with our proposed protocol can advance the understanding of the neurophysiological mechanisms sustaining daily life joint actions and could help defining systems to predict cooperative or competitive behaviors before being overtly expressed, particularly useful in real-life contexts where social behavior is a main feature.

15.
Int J Pharm X ; 4: 100131, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36189458

RESUMO

The aim of this study was to better understand the potential impact of partial vs. complete renewal of the bulk fluid during drug release measurements from poly (lactic-co-glycolic acid) (PLGA)-based implants. A "standard experimental set-up", in which the implants were directly exposed to well agitated phosphate buffer pH 7.4 was used, as well as set-ups, in which the implants were embedded within agarose hydrogels (mimicking living tissue). The gels were exposed to well agitated phosphate buffer pH 7.4. Ibuprofen-loaded implants were prepared by hot melt extrusion. The systems were thoroughly characterized before and during drug release by optical and scanning electron microscopy, gravimetric analysis, pH and solubility measurements as well as gel permeation chromatography. The bulk fluid was either completely or partially replaced by fresh medium at each sampling time point. In all cases, sink conditions were provided in the agitated bulk fluids throughout the experiments. Interestingly, the agarose set-ups did not show any noteworthy impact of the bulk fluid sampling volume on the observed drug release patterns, whereas complete fluid renewal in the "standard set-up" led to accelerated drug release. This could be explained by the considerable fragility of the implants once substantial polymer swelling set on, transforming them into PLGA gels: Complete fluid renewal caused partial disintegration and damage of the highly swollen systems, decreasing the lengths of the diffusion pathways for the drug. The mechanical stress is very much reduced at low sampling volumes, or if the implants are embedded within agarose gels. Thus, great care must be taken when defining the conditions for in vitro drug release measurements from PLGA-based implants: Once substantial system swelling sets on, the devices become highly fragile.

16.
Clin Neuroradiol ; 32(1): 107-115, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34686884

RESUMO

PURPOSE: Despite the high efficacy of flow diverters (FD) in treating sidewall intracranial aneurysms, failures are reported. One of the physical factors determining efficacy is the flow reducing capacity of the FD that is currently unknown to the operator. Our aim was to measure the flow reducing capacity expressed as the hydrodynamic resistance (HR), the metallic surface area (MSA) and pore density (PD) of two different FD designs and quantitatively investigate the impact of sizing and the deployment technique on these parameters. METHODS: Altogether 38 Pipeline (Medtronic) and P64 (Phenox) FD­s were implanted in holder tubes by a neurointerventionist in nominally sized, oversized and longitudinally compressed or elongated manners. The tubes were placed in a flow model with the flow directed across the FD through a side hole on the tube. HR was expressed by the measured pressure drop as the function of the flow rate. Deployed length, MSA and PD were also measured and correlated with the HR. RESULTS: Both PD and MSA changed with varying deployment length, which correlates well with the change in HR. Oversizing the device by 1 mm in diameter has reduced the HR on average to one fifth of the original value for both manufacturers. CONCLUSION: This study demonstrates experimentally that different FD designs have different flow diverting capacities (HR). Parameters are greatly influenced by radial sizing and longitudinal compression or elongation during implantation. Our results might be useful in procedure planning, predicting clinical outcome, and in patient-specific numerical flow simulations.


Assuntos
Hidrodinâmica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Stents
17.
Front Neurorobot ; 16: 863637, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35645762

RESUMO

The industry increasingly insists on academic cooperation to solve the identified problems such as workers' performance, wellbeing, job satisfaction, and injuries. It causes an unsafe and unpleasant working environment that directly impacts the quality of the product, workers' productivity, and effectiveness. This study aimed to give a specialized solution for tests and explore possible solutions to the given problem in neuroergonomics and human-robot interaction. The designed modular and adaptive laboratory model of the industrial assembly workstation represents the laboratory infrastructure for conducting advanced research in the field of ergonomics, neuroergonomics, and human-robot interaction. It meets the operator's anatomical, anthropometric, physiological, and biomechanical characteristics. Comparing standard, ergonomic, guided, and collaborative work will be possible based on workstation construction and integrated elements. These possibilities allow the industry to try, analyze, and get answers for an identified problem, the condition, habits, and behavior of operators in the workplace. The set-up includes a workstation with an industry work chair, a Poka-Yoke system, adequate lighting, an audio 5.0 system, containers with parts and tools, EEG devices (a cap and smartfones), an EMG device, touchscreen PC screen, and collaborative robot. The first phase of the neuroergonomic study was performed according to the most common industry tasks defined as manual, monotonous, and repetitive activities. Participants have a task to assemble the developed prototype model of an industrial product using prepared parts and elements, and instructed by the installed touchscreen PC. In the beginning, the participant gets all the necessary information about the experiment and gets 15 min of practice. After the introductory part, the EEG device is mounted and prepared for recording. The experiment starts with relaxing music for 5 min. The whole experiment lasts two sessions per 60 min each, with a 15 min break between the sessions. Based on the first experiments, it is possible to develop, construct, and conduct complex experiments for industrial purposes to improve the physical, cognitive, and organizational aspects and increase workers' productivity, efficiency, and effectiveness. It has highlighted the possibility of applying modular and adaptive ergonomic research laboratory experimental set-up to transform standard workplaces into the workplaces of the future.

18.
Front Psychol ; 12: 583690, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33633631

RESUMO

Loudness is the magnitude of the auditory sensation that a listener experiences when exposed to a sound. Several sound attributes are reported to affect loudness, such as the sound pressure level at the listener's ears and the spectral content. In addition to these physical attributes of the stimulus, some subjective attributes also appear to affect loudness. When presented with a sound, a listener interacts with an auditory object and can focus on several aspects of the latter. Loudness appears to differ depending on how listeners apprehend this object, notably whether they focus on the sound that reaches their ears or that is produced by the source. The way listeners focus on the auditory object may depend on the stimulus itself. For instance, they might be more likely to focus on the sound emitted by the source if the latter is visible. The instructions given by the experimenters can also explicitly direct the listener's focus on the sound reaching the ears or emitted by the source. The present review aims at understanding how listeners focus on the auditory object depending on the stimuli and instructions they are provided with, and to describe how loudness depends on this focus.

19.
Mol Imaging Biol ; 23(2): 149-159, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33025328

RESUMO

Mass spectrometry imaging (MSI) enables the visualization of molecular distributions on complex surfaces. It has been extensively used in the field of biomedical research to investigate healthy and diseased tissues. Most of the MSI studies are conducted in a 2D fashion where only a single slice of the full sample volume is investigated. However, biological processes occur within a tissue volume and would ideally be investigated as a whole to gain a more comprehensive understanding of the spatial and molecular complexity of biological samples such as tissues and cells. Mass spectrometry imaging has therefore been expanded to the 3D realm whereby molecular distributions within a 3D sample can be visualized. The benefit of investigating volumetric data has led to a quick rise in the application of single-sample 3D-MSI investigations. Several experimental and data analysis aspects need to be considered to perform successful 3D-MSI studies. In this review, we discuss these aspects as well as ongoing developments that enable 3D-MSI to be routinely applied to multi-sample studies.


Assuntos
Imageamento Tridimensional/métodos , Imagem Molecular/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Métodos Analíticos de Preparação de Amostras/métodos , Animais , Pesquisa Biomédica/métodos , Análise de Dados , Humanos , Imageamento Tridimensional/instrumentação , Proteômica/instrumentação , Proteômica/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação
20.
Int Orthod ; 19(3): 512-521, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34272206

RESUMO

INTRODUCTION: The mechanical properties of orthodontic archwires can be defined using experimental setups incorporating brackets that provide conditions closer to those encountered in vivo. We aimed to compare a methodology based on computer-aided design with the gold standard protocol, performed when brackets are engaged to a full-size archwire to test the behaviour of wires in this condition. METHODS: Three models simulating a dental arch with an orthodontic fixed appliance (0.018-inch aesthetic conventional brackets) were designed. The brackets were positioned with a stainless-steel full-size wire on the first two models, with different interbracket distances. The setup 3, based on a computer-assisted design, allowed individualized placement of each bracket. Mean forces recorded and standard deviation were compared for a 0.016×0.022-inch copper-nickel-titanium wire deflected until 2mm. RESULTS: The inter-bracelet distances do not cause a statistical difference in the average maximum force recorded (12.6N and 11.4N; P=0.081) whereas the behaviour of the wires is affected. With setup 3, the recorded efforts (mean value: 8N) are statistically lower than with setup 1 and 2 respectively (P=0.018; P=0.012). CONCLUSION: An individualization of the housings by CAD-CAM dedicated to each bracket optimizes their placement. In our test conditions, the mechanical behaviour of the wires is more influenced by the positioning methods of the brackets than by the value of the interbracket distance. In perspective, our innovative methodology can be extended to other types of brackets.


Assuntos
Braquetes Ortodônticos , Fios Ortodônticos , Computadores , Ligas Dentárias , Análise do Estresse Dentário , Estética Dentária , Fricção , Humanos , Teste de Materiais , Desenho de Aparelho Ortodôntico , Aço Inoxidável , Titânio
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa