Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 770
Filtrar
Mais filtros

Eixos temáticos
Tipo de documento
Intervalo de ano de publicação
1.
Am J Obstet Gynecol ; 230(6): 665.e1-665.e30, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38290925

RESUMO

BACKGROUND: Preterm delivery is associated with cardiovascular remodeling and dysfunction in children and adults. However, it is unknown whether these effects are caused by the neonatal consequences of preterm birth or if these are already present in utero. OBJECTIVE: We evaluated fetal cardiac morphology and function in fetuses of mothers admitted for preterm labor or preterm prelabor rupture of membranes and the association of these changes with the presence of intra-amniotic infection and/or inflammation. STUDY DESIGN: In this prospective cohort study, fetal echocardiography and amniocentesis were performed at admission in singleton pregnant women with preterm labor and/or preterm prelabor rupture of membranes between 24.0 and 34.0 weeks' gestation with (intra-amniotic infection and/or inflammation group, n=41) and without intra-amniotic infection and/or inflammation (non-intra-amniotic infection and/or inflammation, n=54). Controls (n=48) were outpatient pregnant women without preterm labor or preterm prelabor rupture of membranes. Intra-amniotic infection was defined by a positive amniotic fluid culture or positive 16S ribosomal RNA gene. Intra-amniotic inflammation was defined by using the amniotic fluid interleukin-6 cutoff levels previously reported by our group being >1.43 ng/mL in preterm prelabor rupture of membranes and >13.4 ng/mL in preterm labor. Fetal cardiac morphology and function was evaluated using echocardiography, and troponin-I and N-terminal pro-brain natriuretic peptide concentrations were measured in amniotic fluid from women with preterm labor or preterm prelabor rupture of membranes and compared with 20 amniotic fluid Biobank samples obtained for reasons other than preterm labor or preterm prelabor rupture of membranes or cardiac pathology. The data were adjusted for the estimated fetal weight below the 10th percentile and for preterm prelabor rupture of membranes at admission and also for gestational age at amniocentesis when amniotic fluid biomarkers were compared. RESULTS: From 2018 to 2021, 143 fetuses were included; 95 fetuses were from mothers admitted with a diagnosis of preterm labor or preterm prelabor rupture of membranes, and among those, 41 (28.7%) were in the intra-amniotic infection and/or inflammation group and 54 (37.8%) were in the non-intra-amniotic infection and/or inflammation group. A total of 48 (33.6%) fetuses were included in the control group. Fetuses with preterm labor and/or preterm prelabor rupture of membranes had signs of subclinical cardiac concentric hypertrophy (median left wall thickness of 0.93 [interquartile range, 0.72-1.16] in the intra-amniotic infection and/or inflammation group; 0.79 [0.66-0.92] in the non-intra-amniotic infection and/or inflammation group; and 0.69 [0.56-0.83] in controls; P<.001) and diastolic dysfunction (tricuspid A duration 0.23 seconds [0.21-0.25], 0.24 [0.22-0.25], and 0.21 [0.2-0.23]; P=.007). Systolic function was similar among groups. Higher values of amniotic fluid troponin I (1413 pg/mL [927-2334], 1190 [829-1636], and 841 [671-959]; P<.001) and N-terminal pro-brain natriuretic peptide were detected (35.0%, 17%, and 0%; P=.005) in fetuses with preterm labor or preterm prelabor rupture of membranes when compared with the control group. The highest N-terminal pro-brain natriuretic peptide concentrations were found in the intra-amniotic infection and/or inflammation group. CONCLUSION: Fetuses with preterm labor or preterm prelabor rupture of membranes showed signs of cardiac remodeling and subclinical dysfunction, which were more pronounced in those exposed to intra-amniotic infection and/or inflammation. These findings support that the cardiovascular effects observed in children and adults born preterm have, at least in part, a prenatal origin.


Assuntos
Amniocentese , Líquido Amniótico , Corioamnionite , Ruptura Prematura de Membranas Fetais , Trabalho de Parto Prematuro , Humanos , Feminino , Gravidez , Adulto , Estudos Prospectivos , Ecocardiografia , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/metabolismo , Cardiomegalia/diagnóstico por imagem , Estudos de Casos e Controles , Fragmentos de Peptídeos/metabolismo , Interleucina-6/metabolismo , Complicações Infecciosas na Gravidez , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiopatologia , Diástole , Estudos de Coortes
2.
Ultrasound Obstet Gynecol ; 64(1): 50-56, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38197302

RESUMO

OBJECTIVE: Image quality of fetal echocardiography (FE) has improved in the recent era, but few recent studies have reported the accuracy of FE, specifically in single ventricle (SV) congenital heart disease (CHD). This study aimed to assess the ability of FE to correctly predict SV-CHD postnatal anatomy and physiology in a contemporary cohort. METHODS: The contemporary clinical reports of patients with SV-CHD, in which FE was performed between July 2017 and July 2021, were compared with postnatal echocardiograms from a formal quality assurance program. SV fetuses were grouped by anatomical subtype. Diagnostic errors were designated as major if the error would have caused significant alteration in parental counseling or postnatal management. The remaining errors were classified as minor. Physiological discrepancies, including prostaglandin-E (PGE) dependency, atrioventricular valve regurgitation (AVVR), pulmonary venous obstruction and restrictive atrial septum (RAS), were assessed by chart review of the postnatal course. RESULTS: A total of 119 subjects were analyzed. SV subtypes in the cohort included hypoplastic left heart syndrome (HLHS) (n = 68), tricuspid atresia (n = 16), double-inlet left ventricle (n = 12), unbalanced atrioventricular canal (UAVC) (n = 11), heterotaxy (n = 9) and other (n = 3). The rate of major anatomical and physiological errors was low (n = 6 (5.0%)). A higher proportion of minor errors was noted in HLHS and tricuspid atresia, but the differences were not statistically significant. Physiological discrepancies were uncommon, with three major discrepancies, including underestimation of the degree of venous obstruction in one non-HLHS fetus with total anomalous pulmonary venous return, overestimation of RAS in one HLHS fetus and incorrect prediction of PGE dependency in one case false-negative for pulmonary blood flow. No discrepancy in degree of AVVR or RAS affected postnatal care. Minor physiological discrepancies included two false-positive predictions of PGE dependency with one false-positive for ductal-dependent systemic flow and one false-positive for pulmonary blood flow. CONCLUSIONS: In this contemporary review of FE at our center, there was high accuracy in describing anatomical and physiological findings in SV-CHD. Major physiological discrepancies were uncommon but included important cases of false-negative prediction of PGE dependency and underestimation of obstruction of total anomalous pulmonary venous return. These data can inform more accurate counseling of families with SV-CHD fetuses and guide diagnostic improvement efforts. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Ecocardiografia , Cardiopatias Congênitas , Ventrículos do Coração , Ultrassonografia Pré-Natal , Humanos , Feminino , Gravidez , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/embriologia , Ultrassonografia Pré-Natal/métodos , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/embriologia , Ventrículos do Coração/anormalidades , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiopatologia , Coração Fetal/embriologia , Coração Fetal/anormalidades , Erros de Diagnóstico/estatística & dados numéricos , Estudos Retrospectivos , Estudos de Coortes , Adulto , Recém-Nascido
3.
Ultrasound Obstet Gynecol ; 64(1): 36-43, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38339776

RESUMO

OBJECTIVE: Although remarkable strides have been made in fetal medicine and the prenatal diagnosis of congenital heart disease, around 60% of newborns with isolated coarctation of the aorta (CoA) are not identified prior to birth. The prenatal detection of CoA has been shown to have a notable impact on survival rates of affected infants. To this end, implementation of artificial intelligence (AI) in fetal ultrasound may represent a groundbreaking advance. We aimed to investigate whether the use of automated cardiac biometric measurements with AI during the 18-22-week anomaly scan would enhance the identification of fetuses that are at risk of developing CoA. METHODS: We developed an AI model capable of identifying standard cardiac planes and conducting automated cardiac biometric measurements. Our data consisted of pregnancy ultrasound image and outcome data spanning from 2008 to 2018 and collected from four distinct regions in Denmark. Cases with a postnatal diagnosis of CoA were paired with healthy controls in a ratio of 1:100 and matched for gestational age within 2 days. Cardiac biometrics obtained from the four-chamber and three-vessel views were included in a logistic regression-based prediction model. To assess its predictive capabilities, we assessed sensitivity and specificity on receiver-operating-characteristics (ROC) curves. RESULTS: At the 18-22-week scan, the right ventricle (RV) area and length, left ventricle (LV) diameter and the ratios of RV/LV areas and main pulmonary artery/ascending aorta diameters showed significant differences, with Z-scores above 0.7, when comparing subjects with a postnatal diagnosis of CoA (n = 73) and healthy controls (n = 7300). Using logistic regression and backward feature selection, our prediction model had an area under the ROC curve of 0.96 and a specificity of 88.9% at a sensitivity of 90.4%. CONCLUSIONS: The integration of AI technology with automated cardiac biometric measurements obtained during the 18-22-week anomaly scan has the potential to enhance substantially the performance of screening for fetal CoA and subsequently the detection rate of CoA. Future research should clarify how AI technology can be used to aid in the screening and detection of congenital heart anomalies to improve neonatal outcomes. © 2024 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Coartação Aórtica , Inteligência Artificial , Coração Fetal , Ultrassonografia Pré-Natal , Humanos , Feminino , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/embriologia , Gravidez , Ultrassonografia Pré-Natal/métodos , Coração Fetal/diagnóstico por imagem , Coração Fetal/embriologia , Idade Gestacional , Biometria/métodos , Curva ROC , Sensibilidade e Especificidade , Dinamarca , Recém-Nascido , Adulto , Estudos de Casos e Controles , Valor Preditivo dos Testes
4.
Artigo em Inglês | MEDLINE | ID: mdl-38642340

RESUMO

OBJECTIVES: Predicting whether balloon atrial septostomy (BAS) will be necessary after birth for fetuses with d-transposition of the great arteries (d-TGA) remains challenging. We sought to determine whether measurements obtained during fetal maternal hyperoxygenation (MH) testing can improve our ability to predict need for postnatal BAS. METHODS: Forty-one mothers carrying fetuses with d-TGA with either intact ventricular septum or small ventricular septal defect measuring <3mm underwent MH testing between 33-38 weeks gestation. Patent foramen ovale (PFO) size, measured by 2D and color Doppler, patent ductus arteriosus (PDA) shunting (all antegrade versus bidirectional) was assessed in room air (RA) and during MH, blinded to postnatal outcome. BAS status and timing were recorded. RESULTS: Postnatally, 23 neonates underwent BAS while 18 did not, and 14 subjects underwent emergent BAS within 3 hours of life. By univariate analysis, PFO size measured both in RA and MH and all antegrade shunting in the PDA during MH predicted BAS. During MH testing, median PFO size by 2D measured 2.5mm (interquartile range, IQR, 2-3mm) in fetuses who underwent emergent BAS versus 4.1mm (IQR 3.4-5mm) in fetuses who did not undergo BAS (p<0.001). By cutpoint analysis, PFO size during MH testing ≤ 3.2mm predicted need for emergent BAS with sensitivity 93% and specificity 78%. CONCLUSIONS: In d-TGA, measurement of PFO size and direction of PDA shunting during MH testing improves our ability to predict need for BAS postnatally, although additional study is needed. We propose incorporating third trimester MH testing when planning deliveries of d-TGA fetuses. This article is protected by copyright. All rights reserved.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38477180

RESUMO

OBJECTIVE: To compare fetal cardiac function in pregnant women with iron deficiency anemia (IDA) vs healthy pregnant controls. METHODS: This was a single-center, prospective, case-control study conducted in a tertiary hospital between November 2022 and September 2023. Women diagnosed with IDA who attended as outpatients at the pregnancy follow-up clinic at 30-34 weeks' gestation or who were hospitalized for intravenous iron treatment owing to profound anemia were included. The control group consisted of randomly selected gestational-age-matched pregnant women with no obstetric complications or comorbidities and who did not have anemia. Patients underwent two-dimensional imaging, followed by pulsed-wave Doppler and M-mode and tissue Doppler imaging (TDI) to evaluate fetal cardiac function. A fetal cardiac score was calculated using systolic, diastolic and global hemodynamic function parameters, and was compared between patients with IDA and those without. The fetal cardiac score was also assessed according to the severity of anemia in the IDA group. RESULTS: A total of 150 patients, comprising 50 patients with IDA and 100 healthy pregnant women at 30-34 weeks' gestation, were included in the study. Of the patients with IDA, 20 had mild, 18 had moderate and 12 had severe anemia. The fetal myocardial performance index and isovolumetric relaxation time were significantly higher in the IDA group compared with the control group (P < 0.0001 for both), while isovolumetric contraction time was similar. Among the fetal tricuspid and mitral valve diastolic parameters, the E, A and E/A values were significantly lower in the IDA group (P < 0.05 for all). Mitral (MAPSE) and tricuspid (TAPSE) annular plane systolic excursions were significantly lower in the IDA group (P < 0.05 for both). The IDA group also had significantly lower values for the TDI parameters mitral and tricuspid E', A', S' and E'/A' ratio and a significantly higher E/E' ratio (P < 0.05 for all). Among the IDA subgroups, a significant decrease was observed in the tricuspid and mitral A, E and E/A ratio in fetuses whose mothers had severe anemia (P = 0.001). M-mode Doppler analysis revealed significantly lower fetal TAPSE and MAPSE in the patient group with severe maternal anemia (P = 0.001 for both). According to the subgroup comparison of TDI findings, the fetuses of mothers with severe anemia had significantly lower tricuspid and mitral E', A', S' and E'/A' ratio values and a significantly higher E/E' ratio (P < 0.05 for all). The fetal cardiac score was significantly higher in the maternal IDA group compared with the control group (P < 0.001). A significant negative correlation was found between maternal hemoglobin level and fetal cardiac score (P < 0.001). CONCLUSIONS: We observed differences in fetal systolic and diastolic cardiac function in pregnancies with maternal IDA. Fetal cardiac function was affected more among patients with severe anemia. This study found an increased E/E' ratio in the fetuses of pregnant women with IDA, suggesting decreased fetal heart maturation. Prenatal fetal cardiac evaluation, especially in women with severe anemia, can facilitate a more seamless transition to the postnatal period for these newborns. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.

6.
Prenat Diagn ; 2024 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-39367541

RESUMO

Fetal two-dimensional speckle tracking echocardiography (2D-STE) is a novel technique that provides information on fetal heart function by measuring global longitudinal strain (GLS) and global longitudinal strain rate (GLSR). These features assess the longitudinal deformity of the fetal cardiac wall. 2D-STE is shown to be of prognostic value in children and adults with congenital heart disease (CHD). Therefore, its importance in fetal life should also be considered. This systematic review and meta-analysis provides an overview of the literature on 2D-STE (GLS/GLSR) in fetuses with CHD, focusing on the left and right ventricles (LV/RV). Findings indicated that LV-GLS was significantly lower in fetuses with coarctation of the aorta (CoA) and Tetralogy of Fallot (ToF) compared to controls. Conversely, fetuses with a single left ventricle exhibited higher LV-GLS. RV-GLS was significantly lower in fetuses with hypoplastic left heart syndrome (HLHS) and ToF compared to controls. LV-GLSR was significantly lower in fetuses with CoA. Overall, considerable heterogeneity was observed, possibly due to differences in study design. More prospective longitudinal studies on 2D-STE in fetuses with CHD, considering heterogeneity parameters, could offer better insights into this promising technique.

7.
BMC Pregnancy Childbirth ; 24(1): 163, 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38402176

RESUMO

BACKGROUND: Prenatal detection of critical congenital heart disease (CCHD) optimises perinatal decision-making and neonatal outcomes. The objective of this study was to determine the prenatal screening performance, care pathways and perinatal outcomes for prenatally and postnatally diagnosed cases of CCHD over a four-year period. STUDY DESIGN: This retrospective cohort study in a tertiary centre and its two affiliated secondary sites examined all cases of CCHD, including cases of pregnancy termination and in-utero fetal death, neonatal death and liveborn babies that underwent cardiac catheterization or surgery in the first six weeks of life. Prenatal and postnatal data were ascertained from the first trimester assessment for all patients diagnosed prenatally. Cases requiring intervention that were first identified in the postnatal period were included to determine prenatal detection rates. Follow-up for all cases of CCHD continued to one year of age. RESULTS: In a consecutive cohort of 49,950 pregnancies in a 4-year period 01/2019 to 12/2022, a prenatal diagnosis of CCHD was made in 96 cases, yielding a prevalence of 1.9 per 1000 births. The prenatal detection for right duct-dependant heart pathology and congenital heart block was 100%, 85% for left duct-dependant pathology and 93% for transposition of the great arteries (TGA). In the prenatally diagnosed group, 37% of cases were complicated by extracardiac structural abnormalities, a genetic diagnosis or both. All cases of prenatal detection were identified in the context of routine anatomy screening rather than specialist Fetal Cardiac screening services. Almost half of all pregnancies complicated by CCHD did not undergo neonatal cardiac intervention, by virtue of parental choice determined either prenatally or after birth. An additional eight babies were diagnosed with CCHD in the neonatal period, such that the prenatal detection rate for CCHD was 92% (96/104, 95% CI = 84%-96%). Survival at 1-year for infants deemed suitable for CCHD surgery was 85%. CONCLUSION: In a large unselected population, optimal rates of prenatal detection of critical congenital heart disease can be achieved by a protocolised approach to mid-trimester fetal anatomy ultrasound, underpinned by a programme of sonographer education and training. The cardiac abnormalities most likely to evade prenatal detection are left-sided obstructive lesions.


Assuntos
Cardiopatias Congênitas , Transposição dos Grandes Vasos , Lactente , Recém-Nascido , Feminino , Humanos , Gravidez , Estudos Retrospectivos , Perinatologia , Diagnóstico Pré-Natal , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/epidemiologia , Ultrassonografia Pré-Natal
8.
BMC Pregnancy Childbirth ; 24(1): 57, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38212679

RESUMO

BACKGROUND: Hyperglycemia during pregnancy can affect fetal heart in many ways, including causing cardiac malformation, leading to hypertrophic cardiomyopathy and cardiac dysfunction. Echocardiographic evaluation can assist identify alterations in heart structure, morphology and function, enabling prompt monitoring and management. However, according to earlier research, the cardiac alterations are modest in hyperglycemic mothers' fetuses, and might not be detectable using conventional methods and it is also unclear whether these changes are related to the metabolism of mothers. Fetal Heart Quantification (Fetal HQ) can assess ventricular geometry and function more sensitively and thoroughly, and identify sub-clinical cardiac dysfunction. The purpose of this study was to evaluate fetal heart by Fetal HQ in fetuses of hyperglycemic mothers who either had pre-gestational or gestational diabetes and to correlate them with maternal metabolic indices. METHODS: The fetuses of 25 gestational age-matched control mothers, 48 women with gestational diabetes mellitus (GDM), and 11 women with diabetes mellitus (DM) were included in the prospective case-control research. Using fetal echocardiography and speckle tracking echocardiography (STE), the heart of the fetus was evaluated. Differences in the groups' anthropometric, metabolic, and cardiac parameters were examined. It was assessed whether maternal features, prenatal glucose, lipids, and maternal hemoglobin A1c (HbA1c) correlated with fetal cardiac parameters. RESULTS: The LV EDV and ESV were significantly higher in the GDM group as compared to the DM group (p < 0.05). The GSI% was significantly lower in the GDM group compared with the control (p < 0.05). The LV SV and CO of the GDM group were both significantly higher compared with the DM group (p < 0.05). There was a significant decrease in RV FS for segments 1-7 in GDM fetuses compared to the control (p < 0.05) and for segments 5-10 compared to DM (p < 0.05). Fetal cardiac morphology and function indices correlate with maternal pregestational weight, BMI, early pregnancy fast glucose, lipids, and glycemic control levels. CONCLUSIONS: Fetuses exposed to gestational diabetes have altered heart morphology and function that is linked to maternal metabolic parameters, which presents a special indication for performing geometry and function cardiac assessment. Fetal HQ can be employed to evaluate the fetal cardiac shape and function in fetuses exposed to gestational diabetes.


Assuntos
Diabetes Gestacional , Cardiopatias , Gravidez , Feminino , Humanos , Coração Fetal/diagnóstico por imagem , Glucose , Lipídeos , Ultrassonografia Pré-Natal/métodos
9.
BMC Pediatr ; 24(1): 552, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39192246

RESUMO

BACKGROUND: Coarctation of the aorta (CoA) is the most common undiagnosed congenital heart defect during prenatal screening. High false positive and false negative rates seriously affect prenatal consultation and postnatal management. The objective of the study was to assess the utility of various measurements to predict prenatal CoA and to derive a diagnostic algorithm. METHODS: One hundred and fifty-four fetuses with suspected CoA who presented at Fuwai Hospital between December 2017 and August 2021 were enrolled and divided into confirmed CoA cases (n = 47) and false positive cases (n = 107), according to their postnatal outcomes. The transverse aortic arch, isthmus, and descending aorta were measured in the long-axis view of the aortic arch. The angle between the transverse aortic arch (TAO) and the descending aortic arch (DAO) was defined as the TAO-DAO angle and measured in the long axis or sagittal view. Based on the database in GE Voluson E10 and the formula (Z = [Formula: see text]), the standard score (Z-score) of the dimensions of the aorta were calculated in relation to the gestational age. The main echocardiographic indices were combined to design a 3-step diagnostic protocol. The TAO-DAO angle was used as the first step in the diagnostic model. The diameter of the transverse arch and the Z-score of the isthmus were the second step. The third-step indices included a Z-score of the transverse arch, diameter of the isthmus, distance from the left subclavian artery (LSA) to left common carotid artery (LCCA), the ratio of isthmus diameter and LSA diameter and ratio of the distances (the distance between the LSA and LCCA to the distance between the right innominate artery and LCCA). The receiver operating characteristic (ROC) curve determined the predictive capability of each diagnostic parameter, and the kappa test determined the diagnostic accuracy of the proposed model. RESULTS: The cases with confirmed CoA had thinner transverse arches (1.92 ± 0.32 mm vs. 3.06 ± 0.67 mm, P = 0.0001), lower Z-scores of the isthmus (-8.97 ± 1.45 vs. -5.65 ± 1.60, P = 0.0001), smaller TAO-DAO angles (105.54 ± 11.51° vs. 125.29 ± 8.97°, P = 0.0001) and larger distance between the LSA and LCCA (4.45 ± 1.75 mm vs. 2.74 ± 1.07 mm, P = 0.0001) than the false positive cases. The area under the curve (AUC) was 0.947 (95% CI 0.91-0.98) for the TAO-DAO angle ≤ 115.75°, 0.942 (95% CI 0.91-0.98) for the transverse arch diameter ≤ 2.31 mm, 0.937 (95% CI 0.90-0.98) for the Z-score of the isthmus ≤ -7.5, and 0.975 (95% CI 0.95-1.00) for the 3-step diagnostic protocol with 97.8% sensitivity and 97.2% specificity. The kappa test showed that the model's diagnostic accuracy was consistent with postnatal outcomes (kappa value 0.936, P = 0.0001). CONCLUSIONS: The 3-step diagnostic protocol included the three most useful measurements and the additional indices with appropriate cut-off values. The algorithm is useful for the detection of aortic coarctation in fetuses with a high degree of accuracy. TRIAL REGISTRATION: Retrospectively registered.


Assuntos
Aorta Torácica , Coartação Aórtica , Ecocardiografia , Ultrassonografia Pré-Natal , Humanos , Coartação Aórtica/diagnóstico por imagem , Feminino , Gravidez , Aorta Torácica/diagnóstico por imagem , Estudos Retrospectivos , Algoritmos , Idade Gestacional
10.
Echocardiography ; 41(9): e15915, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39258497

RESUMO

This study presents the modified Cordes method, a novel ultrasonographic technique that provides a precise and practical evaluation of fetal situs during pregnancy, particularly in the first and early second trimesters. This method entails precisely aligning the probe and hand to obtain a clear image of the fetal thorax in the axial plane. The fundamental procedures involve ascertaining the initial location of the fetal head, rotating the probe, aligning the thorax at the center, and positioning the left hand to clearly identify the fetal situs. Tests conducted in many pregnancies have verified that the modified Cordes approach offers prompt and precise identification of fetal situs and is more accessible to acquire, particularly for new practitioners. The modified Cordes approach is a straightforward and reliable technique for establishing the position of the fetus. Its application during the first and early second trimesters improves diagnostic accuracy by minimizing the chances of misinterpretation. This method offers benefits by making the process of determining fetal situs more objective and straightforward for practitioners with varying degrees of experience.


Assuntos
Ultrassonografia Pré-Natal , Humanos , Ultrassonografia Pré-Natal/métodos , Feminino , Gravidez , Reprodutibilidade dos Testes , Situs Inversus/diagnóstico por imagem , Situs Inversus/embriologia , Segundo Trimestre da Gravidez
11.
Echocardiography ; 41(6): e15833, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38873982

RESUMO

BACKGROUND: Prenatal echocardiographic assessment of fetal cardiac function has become increasingly important. Fetal two-dimensional speckle-tracking echocardiography (2D-STE) allows the determination of global and segmental functional cardiac parameters. Prenatal diagnostics is relying increasingly on artificial intelligence, whose algorithms transform the way clinicians use ultrasound in their daily workflow. The purpose of this study was to demonstrate the feasibility of whether less experienced operators can handle and might benefit from an automated tool of 2D-STE in the clinical routine. METHODS: A total of 136 unselected, normal, singleton, second- and third-trimester fetuses with normofrequent heart rates were examined by targeted ultrasound. 2D-STE was performed separately by beginner and expert semiautomatically using a GE Voluson E10 (FetalHQ®, GE Healthcare, Chicago, IL). Several fetal cardiac parameters were calculated (end-diastolic diameter [ED], sphericity index [SI], global longitudinal strain [EndoGLS], fractional shortening [FS]) and assigned to gestational age (GA). Bland-Altman plots were used to test agreement between both operators. RESULTS: The mean maternal age was 33 years, and the mean maternal body mass index prior to pregnancy was 24.78 kg/m2. The GA ranged from 16.4 to 32.0 weeks (average 22.9 weeks). Averaged endoGLS value of the beginner was -18.57% ± 6.59 percentage points (pp) for the right and -19.58% ± 5.63 pp for the left ventricle, that of the expert -14.33% ± 4.88 pp and -16.37% ± 5.42 pp. With increasing GA, right ventricular endoGLS decreased slightly while the left ventricular was almost constant. The statistical analysis for endoGLS showed a Bland-Altman-Bias of -4.24 pp ± 8.06 pp for the right and -3.21 pp ± 7.11 pp for the left ventricle. The Bland-Altman-Bias of the ED in both ventricles in all analyzed segments ranged from -.49 mm ± 1.54 mm to -.10 mm ± 1.28 mm, that for FS from -.33 pp ± 11.82 pp to 3.91 pp ± 15.56 pp and that for SI from -.38 ± .68 to -.15 ± .45. CONCLUSIONS: Between both operators, our data indicated that 2D-STE analysis showed excellent agreement for cardiac morphometry parameters (ED and SI), and good agreement for cardiac function parameters (EndoGLS and FS). Due to its complexity, the application of fetal 2D-STE remains the domain of scientific-academic perinatal ultrasound and should be placed preferably in the hands of skilled operators. At present, from our perspective, an implementation into clinical practice "on-the-fly" cannot be recommended.


Assuntos
Ecocardiografia , Coração Fetal , Ultrassonografia Pré-Natal , Humanos , Feminino , Gravidez , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiopatologia , Ultrassonografia Pré-Natal/métodos , Ecocardiografia/métodos , Adulto , Reprodutibilidade dos Testes , Estudos de Viabilidade , Idade Gestacional
12.
Echocardiography ; 41(8): e15879, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39010837

RESUMO

Type III redundancy of the foramen ovale flap (RFOF) mimics hemodynamic changes of mitral stenosis(MS), which has not been particularly highlighted in previous literature but carries a favorable prognosis.


Assuntos
Hemodinâmica , Estenose da Valva Mitral , Humanos , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/cirurgia , Hemodinâmica/fisiologia , Diagnóstico Diferencial , Feminino , Forame Oval/fisiopatologia , Forame Oval/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos
13.
Echocardiography ; 41(3): e15790, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38456327

RESUMO

PURPOSE: Our aim in this study was to investigate the prenatal and postnatal prognosis of double outlet right ventricle (DORV) cases diagnosed prenatally by analyzing the outcomes based on the subtype. METHODS: This study is a retrospective chart review. Cases diagnosed with fetal DORV by prenatal ultrasound in the maternal-fetal medicine department of our hospital between 2014 and 2022 were included. Data on maternal characteristics, fetal echocardiographic features (type of DORV), pregnancy and neonatal outcomes (termination of pregnancy [TOP], intrauterine fetal death [IUD], neonatal death [NND], death in infancy (IND), survival) were collected and analyzed. RESULTS: Ninety-nine cases of prenatally diagnosed cases of DORV were included. The prenatal diagnosis was right in 97% of the liveborn fetuses. The cases were classified into subtypes, including transposition of great arteries (TGA), Fallot, ventricular septal defect (VSD), remote, and heterotaxy types. The cohort consisted of 32.3% TGA type, 19.1% fallot type, 11.1% VSD type, 2% remote type, and 35.3% heterotaxy type of DORV. An additional cardiac anomaly was observed in 87% and an extra-cardiac anomaly was observed in 54% of the cases. When we excluded the cases with heterotaxy type but without any chromosomal abnormality, additional genetic abnormalities were detected in 42% of the remaining cases. Outcome of pregnancy was livebirth in 68/99 (68.7%), IUFD in 5/99 (5.1%), and TOP in 26/99 (26.3%). Postnatal cardiac surgical repair was performed in 48 cases. Survival among livebirths was 39/68 (57.3%). Twenty-nine neonates or infants who had additional cardiac anomalies and/or genetic abnormalities died before any surgical intervention. The postoperative survival rate was 39/48 (81.2%). CONCLUSION: The prognosis in DORV depends on the anatomical subtype, the presence, and severity of associated anomalies. Survival increases in isolated cases without any additional structural or genetic anomalies.


Assuntos
Dupla Via de Saída do Ventrículo Direito , Cardiopatias Congênitas , Comunicação Interventricular , Transposição dos Grandes Vasos , Gravidez , Lactente , Recém-Nascido , Feminino , Humanos , Dupla Via de Saída do Ventrículo Direito/diagnóstico por imagem , Dupla Via de Saída do Ventrículo Direito/cirurgia , Estudos Retrospectivos , Cardiopatias Congênitas/diagnóstico por imagem , Prognóstico
14.
Echocardiography ; 41(7): e15870, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38979798

RESUMO

Evaluation of the fetal heart involves two approaches. The first describes a screening protocol in which the heart is imaged in transverse planes that includes the four-chamber view (4CV), left and right outflow tracts, and the 3-vessel-tracheal view. The second approach is a fetal echocardiogram that requires additional cardiac images as well as evaluating ventricular function using diagnostic tools such as M-mode and pulsed Doppler ultrasound. Speckle tracking analysis of the ventricular and atrial endocardium of the fetal heart has focused primarily on computing longitudinal global strain. However, the technology enabling this measurement to occur has recently been adapted to enable the clinician to obtain numerous additional measurements of the size, shape, and contractility of the ventricles and atrial chambers. By using the increased number of measurements derived from speckle tracking analysis, we have reported the ability to screen for tetralogy of Fallot, D-transposition of the great arteries (D-TGA), and coarctation of the aorta by only imaging the 4CV. In addition, we have found that measurements derived from speckle tracking analysis of the ventricular and atrial chambers can be used to compute the risk for emergent neonatal balloon atrial septostomy in fetuses with D-TGA. The purpose of this review is to consolidate our experience in one source to provide perspective on the benefits of speckle tracking analysis to measure the size, shape, and contractility of the ventricles and atria imaged in the 4CV in fetuses with congenital heart defects.


Assuntos
Coração Fetal , Cardiopatias Congênitas , Contração Miocárdica , Ultrassonografia Pré-Natal , Humanos , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/embriologia , Ultrassonografia Pré-Natal/métodos , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiopatologia , Contração Miocárdica/fisiologia , Ecocardiografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Interpretação de Imagem Assistida por Computador/métodos , Feminino
15.
J Ultrasound Med ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38923585

RESUMO

BACKGROUND: Although the fetal sphericity index (SI) and fractional shortening (FS) of 24 transverse segments have been previously reported after the 20th gestational week, there have been no reports during the first and early second trimester. OBJECTIVE: This study aimed to clarify the SI and FS of 24 transverse segments in normal fetuses before the 20th gestational week. METHODS: A total of 101 normal fetuses aged between 12 and 20 gestational weeks were examined. The displacement of the ventricular endocardium during the cardiac cycle was computed using speckle-tracking software (GE Healthcare, Milwaukee, WI). We analyzed the length of 24 end-diastolic lateral segments and the end-diastolic basal (seg1-6)- middle (Seg7-15)-apical (Seg16-24) distribution from the base to the apex of each ventricle, according to the method described by DeVore et al. The SI and FS were computed for each of the 24 segments by dividing the mid-basal-apical length by the transverse size. RESULTS: The SI for each segment was independent of the gestational age. The SI of the right ventricle was significantly lower than that of the left ventricle for segments 1-14, suggesting that the right ventricle was more spherical than the left ventricle in the basal segment only. The FS of the right ventricle was significantly lower than that of the left ventricle in segments 1 to 2 and 13 to 24. CONCLUSION: The morphology of the ventricles before 20 weeks of gestation differs from that between 20 and 40 weeks of gestation. This difference may be related to myocardial densification or performance.

16.
J Ultrasound Med ; 2024 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-39425632

RESUMO

OBJECTIVE: This study compared the accuracy of prenatal congenital heart disease (CHD) diagnosed by maternal-fetal medicine specialists (MFMs) and pediatric cardiologists (PCs), using postnatal cardiac findings as the reference standard. METHODS: This retrospective analysis at Siriraj Hospital, Bangkok, Thailand, involved 125 pregnancies with fetal CHD diagnosed by MFMs and evaluated by PCs later. Prenatal CHD diagnoses by either MFM or PC were compared with postnatal diagnoses obtained through echocardiography, cardiac surgery/catheterization, or autopsy. Diagnostic accuracy was classified as (A) correct diagnosis, (B) minor differences not impacting clinical management or outcomes, or (C) major differences affecting prognosis or treatment. RESULTS: Cardiac sonography by MFM achieved diagnostic accuracies of 73.6% (A), 16% (B), and 10.4% (C), while fetal echocardiography by PC resulted in accuracies of 72% (A), 20% (B), and 8% (C). No statistically significant differences were found between MFM and PC in each category (P = .375-.832). The MFMs' accuracy was highest for tetralogy of Fallot (94.4%; 95% CI, 72.7-99.9%) and lowest for right atrial isomerism (71.4%; 95% CI, 29-96.3%) and pulmonary atresia with ventricular septal defect (57.1%; 95% CI, 18.4-90.1%). CONCLUSIONS: MFMs and PCs demonstrated high and comparable accuracy in prenatal CHD diagnosis. Although PCs tended to outperform MFMs in cases where misdiagnosis could significantly impact neonatal care and outcomes, MFMs can effectively perform primary screening for fetal CHD in all pregnancies. Collaboration with PCs remains essential when fetal CHD is suspected, particularly in complex cases.

17.
J Ultrasound Med ; 43(5): 851-861, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38213069

RESUMO

OBJECTIVES: To investigate whether fetal cardiac function is affected by underlying heart disease in pregnant women. METHODS: A total of 100 pregnant women who were ≥34 gestational weeks were included in the study, 40 in the maternal heart disease (MHD) group diagnosed with heart disease and 60 in the control group. All cardiac diseases in pregnant women were diagnosed preconceptionally and categorized according to the New York Heart Association (NYHA) classification system. Fetal cardiac functions of study groups were evaluated by M-mode, color tissue Doppler imaging (c-TDI), and pulsed wave Doppler. RESULTS: Tricuspid annular plane systolic excursion and myocardial performance index (MPI) values were significantly higher and isovolumetric relaxation time was prolonged in the MHD group. The MPI value was found higher in MHD group with NYHA Class II compared to those with NYHA Class I. No significant change in any of the fetal tricuspid annular peak velocity values measured by c-TDI in the MHD group. There were no differences in fetal cardiac functions and perinatal outcomes between pregnant women with acquired and congenital heart diseases. Patients in NYHA Class II had lower birth weight, 1st and 5th minute APGAR scores, and higher neonatal intensive care unit admission rates. CONCLUSIONS: Underlying heart diseases in pregnant women can cause alterations in the systolic and diastolic function of the fetal heart. High fetal MPI values detected in cardiac patients may indicate that cardiac pathologies during pregnancy affect fetal cardiac globular myocardial function. Cardiac pathologies that progress with restricted physical activity may cause changes in fetal cardiac function and may be associated with adverse perinatal outcomes.


Assuntos
Cardiopatias , Recém-Nascido , Humanos , Gravidez , Feminino , Cardiopatias/complicações , Cardiopatias/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem , Sístole , Estudos Prospectivos , Diástole , Ultrassonografia Pré-Natal/métodos
18.
J Ultrasound Med ; 43(5): 841-849, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38240409

RESUMO

OBJECTIVES: The aims of this study were to assess the vortex characteristics of left ventricle (LV) in fetuses with coarctation of the aorta (CoA) using high-frame rate ultrasound with blood speckle-tracking (BST) and explore its relationships with cardiac function and morphology parameters. METHODS: Thirty fetuses with CoA and 30 gestational-age matched normal fetuses were included in this cross-sectional study. The area, length, width, and position of the vortex in the LV were recorded and quantitatively analyzed by BST echocardiography. The associations of vortex properties with ventricular function and morphology were also determined. RESULTS: Based on BST imaging, the LV vortex can be observed in 93% of the fetuses. The fetuses with CoA exhibited significantly larger and wider vortex than the controls (P < .05). Linear regression analysis indicated that vortex area was positively related to sphericity index of LV as well as isovolumic relaxation time (r = .52, P = .003 and r = .42, P = .021). There was a negative correlation between vortex area and mitral valve size (r = -.443, P = .014). No significant association was found between vortex area and myocardial performance index and aortic isthmus size. CONCLUSIONS: It is feasible to quantitatively evaluate the left ventricular vortex in fetuses by BST. The fetuses with CoA exhibited greater vortex area and width, and the altered vortex property is associated with geometry of LV. This will facilitate our comprehension of the unique flow patterns and early cardiac remodeling in fetuses with CoA.


Assuntos
Coartação Aórtica , Humanos , Gravidez , Feminino , Coartação Aórtica/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Estudos Transversais , Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem
19.
J Ultrasound Med ; 43(7): 1319-1331, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38567690

RESUMO

OBJECTIVES: The aim of the study was to compare left ventricle stroke volume in healthy, eutrophic fetuses in the 2nd and 3rd trimesters evaluated using the velocity time integral and aortic annulus area with left ventricular stroke volume measured using Simpson's single-plane rule and to determine the discrepancy equation. METHODS: The study included 354 fetuses. In each fetus, during the same examination, simultaneous assessment of stroke volume was performed by pulsed-wave Doppler using the product of the velocity time integral and aortic annulus area and by the fetalHQ® software using Simpson's single-plane rule. The Mann-Whitney U test was used to compare the "product-derived" stroke volume and stroke volume using fetalHQ® software values in the 2nd and 3rd trimesters separately. The agreement between the two methods were verified using Bland-Altman analysis. A linear regression model was used to obtain the discrepancy equation. RESULTS: In the 2nd trimester, the mean percentage difference between both the techniques showed that the stroke volume values determined using pulsed-wave Doppler were, on average, 88% higher than the stroke volume values determined using fetalHQ®. The upper limit of agreement between the compared techniques was approximately 146% and the lower limit of agreement was equal to 29.6%. In the 3rd trimester, the results indicated that the stroke volume values determined using pulsed-wave Doppler were, on average, 76% higher than the stroke volume values determined using fetalHQ®. The upper limit of agreement between the compared techniques was approximately 129% and the lower limit of agreement was 23%. Based on the results of the linear regression models, discrepancy formulas of the stroke volume values were obtained. The equations to calculate the predicted mean and standard deviations were used to compute the reference intervals for the mean, 5th and 95th centiles. CONCLUSION: The calculation of left ventricular stroke volume using pulsed Doppler has higher result in relation to stroke volume determined using Simpson's rule significantly. The aortic annulus area showed a higher correlation regarding stroke volume than the velocity time integral in both the 2nd and 3rd trimesters. Stroke volume increased with the increase in aortic annulus area, whereas the velocity time integral remained relatively constant. The retrospective analysis of the collected material enabled the determination of the discrepancy equation.


Assuntos
Ventrículos do Coração , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Volume Sistólico , Ultrassonografia Pré-Natal , Humanos , Feminino , Gravidez , Ultrassonografia Pré-Natal/métodos , Volume Sistólico/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/embriologia , Reprodutibilidade dos Testes , Coração Fetal/diagnóstico por imagem , Coração Fetal/embriologia , Adulto , Interpretação de Imagem Assistida por Computador/métodos
20.
J Perinat Med ; 52(3): 322-326, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38298153

RESUMO

OBJECTIVES: To evaluate the changes of cardiac morphology and function in fetuses conceived through assisted reproductive technologies (ART) by speckle tracking echocardiography. METHODS: A retrospective study was conducted in 101 spontaneously conceived (SC) fetuses and 99 ART-conceived ones. Fetal echocardiography was performed, fetal cardiac morphology and function were analyzed using two-dimensional speckle tracking software, including global sphericity index (GSI), global longitudinal strain (GLS), fractional area change (FAC) of the left and right ventricles, as well as segmental sphericity index (SI), end-diastolic diameter (ED), and fractional shortening (FS) in 24 segments. RESULTS: Compared to the SC fetuses, the ART-conceived fetuses exhibited decreased GSI (median [interquartile range], 1.22 [1.16-1.27] vs. 1.18 [1.11-1.24], p=0.007), decreased right ventricular GLS (24.9 [21.5-27.6] vs. 23.2 [20.4-26.8], p=0.026), and decreased right ventricular FAC (mean ± standard deviation, 39.7 ± 6.4 vs. 37.2 ± 7.1, p=0.003). Analysis of the 24 segments showed that ART-conceived fetuses had reduced SI in the apical segments of right ventricle and increased ED in several segments of the right ventricle. CONCLUSIONS: Fetuses conceived through ART had a more spherical shape of the global heart and predominantly right-sided cardiac remodeling and systolic function impairment.


Assuntos
Ecocardiografia , Coração Fetal , Humanos , Estudos Retrospectivos , Coração Fetal/diagnóstico por imagem , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Técnicas de Reprodução Assistida
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa