Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Curr Issues Mol Biol ; 45(6): 4985-5004, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37367066

RESUMO

Tumour suppressor p53 plays a key role in the development of cancer and has therefore been widely studied in recent decades. While it is well known that p53 is biologically active as a tetramer, the tetramerisation mechanism is still not completely understood. p53 is mutated in nearly 50% of cancers, and mutations can alter the oligomeric state of the protein, having an impact on the biological function of the protein and on cell fate decisions. Here, we describe the effects of a number of representative cancer-related mutations on tetramerisation domain (TD) oligomerisation defining a peptide length that permits having a folded and structured domain, thus avoiding the effect of the flanking regions and the net charges at the N- and C-terminus. These peptides have been studied under different experimental conditions. We have applied a variety of techniques, including circular dichroism (CD), native mass spectrometry (MS) and high-field solution NMR. Native MS allows us to detect the native state of complexes maintaining the peptide complexes intact in the gas phase; the secondary and quaternary structures were analysed in solution by NMR, and the oligomeric forms were assigned by diffusion NMR experiments. A significant destabilising effect and a variable monomer population were observed for all the mutants studied.

2.
Proc Natl Acad Sci U S A ; 117(22): 11908-11915, 2020 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-32414918

RESUMO

Water wires are critical for the functioning of many membrane proteins, as in channels that conduct water, protons, and other ions. Here, in liquid crystalline lipid bilayers under symmetric environmental conditions, the selective hydrogen bonding interactions between eight waters comprising a water wire and a subset of 26 carbonyl oxygens lining the antiparallel dimeric gramicidin A channel are characterized by 17O NMR spectroscopy at 35.2 T (or 1,500 MHz for 1H) and computational studies. While backbone 15N spectra clearly indicate structural symmetry between the two subunits, single site 17O labels of the pore-lining carbonyls report two resonances, implying a break in dimer symmetry caused by the selective interactions with the water wire. The 17O shifts document selective water hydrogen bonding with carbonyl oxygens that are stable on the millisecond timescale. Such interactions are supported by density functional theory calculations on snapshots taken from molecular dynamics simulations. Water hydrogen bonding in the pore is restricted to just three simultaneous interactions, unlike bulk water environs. The stability of the water wire orientation and its electric dipole leads to opposite charge-dipole interactions for K+ ions bound at the two ends of the pore, thereby providing a simple explanation for an ∼20-fold difference in K+ affinity between two binding sites that are ∼24 Šapart. The 17O NMR spectroscopy reported here represents a breakthrough in high field NMR technology that will have applications throughout molecular biophysics, because of the acute sensitivity of the 17O nucleus to its chemical environment.


Assuntos
Gramicidina/química , Canais Iônicos/química , Espectroscopia de Ressonância Magnética/métodos , Água/química , Sítios de Ligação , Fenômenos Biofísicos , Microambiente Celular , Biologia Computacional , Ligação de Hidrogênio , Canais Iônicos/metabolismo , Bicamadas Lipídicas/química , Bicamadas Lipídicas/metabolismo , Modelos Moleculares , Isótopos de Oxigênio/metabolismo
3.
Chemphyschem ; 23(19): e202200215, 2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-35896954

RESUMO

Selectivity and image contrast are always challenging in magnetic resonance imaging (MRI), which are - inter alia - addressed by contrast agents. These compounds still need to be improved, and their relaxation properties, i. e., their paramagnetic relaxation enhancement (PRE), needs to be understood. The main goal is to improve specificity and relaxivities, especially at the high magnetic fields currently exploited not only in material science but also in the medical environment. Longitudinal and transverse relaxivities, r1 and r2 , which correspond to the longitudinal and transverse relaxation rates R1 and R2, normalized to the concentration of the paramagnetic moieties, need to be considered because both contribute to the image contrast. 1 H-relaxivities r1 and r2 of high-spin heterometallic clusters were studied containing lanthanide and transition-metal ions within a polyoxometalate matrix. A wide range of magnetic fields from 0.5 T/20 MHz to 33 T/1.4 GHz was applied. The questions addressed here concern the rotational and diffusion correlation times which determine the relaxivities and are affected by the solvent's viscosity. Moreover, the variation of the lanthanide and transition-metal ions of the clusters provided insights into the sensitivity of PRE with respect to the electron spin properties of the paramagnetic centers as well as cooperative effects between lanthanides and transition metal ions.


Assuntos
Meios de Contraste , Elementos da Série dos Lantanídeos , Ânions , Meios de Contraste/química , Íons , Elementos da Série dos Lantanídeos/química , Imageamento por Ressonância Magnética , Polieletrólitos , Solventes
4.
Environ Sci Technol ; 56(6): 3758-3769, 2022 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-35213127

RESUMO

Most oceanic dissolved organic matter (DOM) is still not fully molecularly characterized. We combined high-field nuclear magnetic resonance (NMR) and ultrahigh-resolution mass spectrometry (Fourier-transform ion cyclotron resonance mass spectrometry, FT-ICR-MS) for the structural and molecular formula-level characterization of solid-phase extracted (SPE) DOM from surface, mesopelagic, and bathypelagic Atlantic and Pacific Ocean samples. Using a MicroCryoProbe, unprecedented low amounts of SPE-DOM (∼1 mg carbon) were sufficient for two-dimensional NMR analysis. Low proportions of olefinic and aromatic relative to aliphatic and carboxylated structures (NMR) at the sea surface were likely related to photochemical transformations. This was consistent with lower molecular masses and higher degrees of saturation and oxygenation (FT-ICR-MS) compared to those of the deep sea. Carbohydrate structures in the mesopelagic North Pacific Ocean suggest export and release from sinking particles. In our sample set, the universal molecular DOM composition, as captured by FT-ICR-MS, appears to be structurally more diverse when analyzed by NMR, suggesting DOM variability across oceanic provinces to be more pronounced than previously assumed. As a proof of concept, our study takes advantage of new complementary approaches resolving thousands of structural and molecular DOM features while applying reasonable instrument times, allowing for the analysis of large oceanic data sets to increase our understanding of marine DOM biogeochemistry.


Assuntos
Matéria Orgânica Dissolvida , Água , Espectrometria de Massas/métodos , Peso Molecular , Água/química
5.
Magn Reson Chem ; 58(4): 305-311, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31909497

RESUMO

Nuclear magnetic resonance (NMR)-based fluxomics seeks to measure the incorporation of isotope labels in selected metabolites to follow kinetically the synthesis of the latter. It can however equally be used to understand the biosynthetic origin of the same metabolites. We investigate here different NMR approaches to optimize such experiments in terms of resolution and time requirement. Using the isoleucine biosynthesis as an example, we explore the use of different field strengths ranging from 500 MHz to 1.1 GHz. Because of the different field dependence of chemical shift and heteronuclear J couplings, the spectra change at different field strengths. We equally explore the approach to silence the leucine/valine methyl signals through the use of a suitable deuterated precursor, thereby allowing selective observation of the Ile 13 C labeling pattern. Combining both approaches, we arrive at an efficient procedure for the NMR-based exploration of Ile biosynthesis.

6.
Int J Mol Sci ; 21(16)2020 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-32784642

RESUMO

NMR is a powerful spectroscopic method that can provide information on the structural disorder in solids, complementing scattering and diffraction techniques. The structural disorder in solids can generate a dispersion of local magnetic and electric fields, resulting in a distribution of isotropic chemical shift δiso and quadrupolar coupling CQ. For spin-1/2 nuclei, the NMR linewidth and shape under high-resolution magic-angle spinning (MAS) reflects the distributions of isotropic chemical shift, providing a rich source of disorder information. For quadrupolar nuclei, the second-order quadrupolar broadening remains present even under MAS. In addition to isotropic chemical shift, structural disorder can impact the electric field gradient (EFG) and consequently the quadrupolar NMR parameters. The distributions of quadrupolar coupling and isotropic chemical shift are superimposed with the second-order quadrupolar broadening, but can be potentially characterized by MQMAS (multiple-quantum magic-angle spinning) spectroscopy. We review analyses of NMR lineshapes in 2D DQ-SQ (double-quantum single-quantum) and MQMAS spectroscopies, to provide a guide for more general lineshape analysis. In addition, methods to enhance the spectral resolution and sensitivity for quadrupolar nuclei are discussed, including NMR pulse techniques and the application of high magnetic fields. The role of magnetic field strength and its impact on the strategy of determining optimum NMR methods for disorder characterization are also discussed.


Assuntos
Espectroscopia de Ressonância Magnética , Marcadores de Spin , Simulação por Computador , Modelos Teóricos
7.
Angew Chem Int Ed Engl ; 57(44): 14498-14502, 2018 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-29508496

RESUMO

NMR spectroscopy at ultra-high magnetic fields requires improved radiofrequency (rf) pulses to cover the increased spectral bandwidth. Optimized 90° pulse pairs were introduced as Ramsey-type cooperative (Ram-COOP) pulses for biomolecular NMR applications. The Ram-COOP element provides broadband excitation with enhanced sensitivity and reduced artifacts even at magnetic fields >1.0 GHz 1 H Larmor frequency (23 T). A pair of 30 µs Ram-COOP pulses achieves an excitation bandwidth of 100 kHz with a maximum rf field of 20 kHz, more than three-fold improved compared to excitation by rectangular pulses. Ram-COOP pulses exhibit little offset-dependent phase errors and are robust to rf inhomogeneity. The performance of the Ram-COOP element is experimentally confirmed with heteronuclear multidimensional NMR experiments, applied to proteins and nucleic acids. Ram-COOP provides broadband excitation at low rf field strength suitable for application at current magnetic fields and beyond 23 T.


Assuntos
Ressonância Magnética Nuclear Biomolecular/métodos , Algoritmos , Artefatos , Simulação por Computador
8.
Anal Bioanal Chem ; 409(30): 7223-7234, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29030668

RESUMO

Monitoring of chemical reactions in real-time is in demand for process control. Different methods such as gas chromatography (GC), mass spectroscopy, infrared spectroscopy, and nuclear magnetic resonance (NMR) are used for that purpose. The current state-of-the-art compact NMR systems provide a useful method to employ with various reaction conditions for studying chemical reactions inside the fume hood at the chemical workplace. In the present study, an acetalization reaction was investigated with compact NMR spectroscopy in real-time. Acetalization is used for multistep synthesis of the variety of organic compounds to protect particular chemical groups. A compact 1 T NMR spectrometer with a permanent magnet was employed to monitor the acid catalyzed acetalization of the p-nitrobenzaldehyde with ethylene glycol. The concentrations of both reactant and product were followed by peak integrals in single-scan 1H NMR spectra as a function of time. The reaction conditions were varied in terms of temperature, agitation speed, catalyst loading, and feed concentrations in order to determine the activation energy with the help of a pseudo-homogeneous kinetic model. For low molar ratios of aldehyde and glycol, the equilibrium conversions were lower than for the stoichiometric ratio. Increasing catalyst concentration leads to faster conversion. The data obtained with low-field NMR spectroscopy were compared with data from GC and NMR spectroscopy at 9.4 T acquired in batch mode by extracting samples at regular time intervals. The reaction kinetics followed by either method agreed well. The activation energies for forward and backward reactions were determined by real-time monitoring with compact NMR at 1 T were 48 ± 5 and 60 ± 4 kJ/mol, respectively. The activation energies obtained with gas chromatography for forward and backward reactions were 48 ± 4 and 51 ± 4 kJ/mol. The equilibrium constant decreases with increasing temperature as expected for an exothermic reaction. The impact of dense sampling with online NMR and sparse sampling with GC was observed on the kinetic outcome using the same kinetic model. Graphical abstract Acetalization reaction kinetics were monitored with real-time desktop NMR spectroscopy at 1 T. Each data point was obtained at regular intervals with a single shot in 15 s. The kinetics was compared with sparsely sampled data obtained with GC and NMR at 9.4 T.

9.
Magn Reson Chem ; 55(10): 902-908, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28437584

RESUMO

The potential of high-field NMR to measure solid-state 95 Mo and 183 W NMR in polyoxometalates (POMs) is explored using some archetypical structures like Lindqvist, Keggin and Dawson as model compounds that are well characterized in solution. NMR spectra in static and under magic angle spinning (MAS) were obtained, and their analysis allowed extraction of the NMR parameters, including chemical shift anisotropy and quadrupolar coupling parameters. Despite the inherent difficulties of measurement in solid state of these low-gamma NMR nuclei, due mainly to the low spectral resolution and poor signal-to-noise ratio, the observed global trends compare well with the solution-state NMR data. This would open an avenue for application of solid-state NMR to POMs, especially when liquid-state NMR is not possible, e.g., for poorly soluble or unstable compounds in solution, and for giant molecules with slow tumbling motion. This is the case of Keplerate where we provide here the first NMR characterization of this class of POMs in the solid state. Copyright © 2017 John Wiley & Sons, Ltd.

10.
Angew Chem Int Ed Engl ; 55(34): 9886-9, 2016 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-27417269

RESUMO

Nuclear magnetic resonance (NMR) studies have benefited tremendously from the steady increase in the strength of magnetic fields. Spectacular improvements in both sensitivity and resolution have enabled the investigation of molecular systems of rising complexity. At very high fields, this progress may be jeopardized by line broadening, which is due to chemical exchange or relaxation by chemical shift anisotropy. In this work, we introduce a two-field NMR spectrometer designed for both excitation and observation of nuclear spins in two distinct magnetic fields in a single experiment. NMR spectra of several small molecules as well as a protein were obtained, with two dimensions acquired at vastly different magnetic fields. Resonances of exchanging groups that are broadened beyond recognition at high field can be sharpened to narrow peaks in the low-field dimension. Two-field NMR spectroscopy enables the measurement of chemical shifts at optimal fields and the study of molecular systems that suffer from internal dynamics, and opens new avenues for NMR spectroscopy at very high magnetic fields.

11.
Solid State Nucl Magn Reson ; 61-62: 54-61, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24973027

RESUMO

The feasibility of obtaining (75)As and (1)(21/123)Sb NMR spectra for solids at high and moderate magnetic field strengths is explored. Arsenic-75 nuclear quadrupolar coupling constants and chemical shifts have been measured for arsenobetaine bromide and tetraphenylarsonium bromide. Similarly, (121/123)Sb NMR parameters have been measured for tetraphenylstibonium bromide and potassium hexahydroxoantimonate. The predicted pseudo-tetrahedral symmetry at arsenic and the known trigonal bipyramidal symmetry at antimony in their respective tetraphenyl-bromide "salts" are reflected in the measured (75)As and (121)Sb nuclear quadrupole coupling constants, CQ((75)As)=7.8MHz and CQ((121)Sb)=159MHz, respectively. Results of density functional theory quantum chemistry calculations for isolated molecules using ADF and first-principles calculations using CASTEP, a gauge-including projector augmented wave method to deal with the periodic nature of solids, are compared with experiment. Although the experiments can be time consuming, measurements of (75)As and (121)Sb NMR spectra (at 154 and 215MHz, respectively, i.e., at B0=21.14T) with linewidths in excess of 1MHz are feasible using uniform broadband excitation shaped pulse techniques (e.g., WURST and WURST-QCPMG).

12.
Anal Sci ; 40(1): 101-113, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37819571

RESUMO

With the prevalence of glucosamine- and chondroitin-containing dietary supplements for people with osteoarthritis in the marketplace, it is important to have an accurate and reproducible analytical method for the quantitation of these compounds in finished products. NMR spectroscopic method based both on low- (80 MHz) and high- (500-600 MHz) field NMR instrumentation was established, compared and validated for the determination of chondroitin sulfate and glucosamine in dietary supplements. The proposed method was applied for analysis of 20 different dietary supplements. In the majority of cases, quantification results obtained on the low-field NMR spectrometer are similar to those obtained with high-field 500-600 MHz NMR devices. Validation results in terms of accuracy, precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit for purpose for the marketed products. The NMR method was extended to the analysis of methylsulfonylmethane, adulterant maltodextrin, acetate and inorganic ions. Low-field NMR can be a quicker and cheaper alternative to more expensive high-field NMR measurements for quality control of the investigated dietary supplements. High-field NMR instrumentation can be more favorable for samples with complex composition due to better resolution, simultaneously giving the possibility of analysis of inorganic species such as potassium and chloride.


Assuntos
Glucosamina , Osteoartrite , Humanos , Reprodutibilidade dos Testes , Suplementos Nutricionais/análise , Sulfatos de Condroitina/análise
13.
Anal Chim Acta ; 1273: 341537, 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37423668

RESUMO

Despite the advances in low-field nuclear magnetic resonance (NMR), there are limited spectroscopic applications for untargeted analysis and metabolomics. To evaluate its potential, we combined high-field and low-field NMR with chemometrics for the differentiation between virgin and refined coconut oil and for the detection of adulteration in blended samples. Although low-field NMR has less spectral resolution and sensitivity compared to high-field NMR, it was still able to achieve a differentiation between virgin and refined coconut oils, as well as between virgin coconut oil and blends, using principal component analysis (PCA), partial least squares discriminant analysis (PLS-DA), and random forest techniques. These techniques were not able to distinguish between blends with different levels of adulteration; however, partial least squares regression (PLSR) enabled the quantification of adulteration levels for both NMR approaches. Given the significant benefits of low-field NMR, including economic and user-friendly analysis and fitting in an industrial environment, this study establishes the proof of concept for its utilization in the challenging scenario of coconut oil authentication. Also, this method has the potential to be used for other similar applications that involve untargeted analysis.


Assuntos
Contaminação de Alimentos , Óleos de Plantas , Azeite de Oliva/análise , Óleo de Coco/análise , Contaminação de Alimentos/análise , Óleos de Plantas/análise , Espectroscopia de Ressonância Magnética
14.
Forensic Sci Int ; 340: 111450, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36152449

RESUMO

In this study, fluorine-19 nuclear magnetic resonance spectroscopy (19F NMR) served as a highly specific tool for identification of fluorinated new psychoactive substances (NPS) as well as a suitable analytical method for the accurate quantification of fluorinated NPS in different seized samples. In the first part of the study, 19F NMR spectroscopy of a number of different fluorinated NPS, including 51 synthetic cannabinoids, 8 synthetic cathinones, 7 phenethylamines, 8 fentanyl analogues, and 9 other types of compounds was conducted. The chemical shifts and multiplet of the primary fluorides (RCH2F), fluorobenzenes (ortho-ArF, meta-ArF, and para-ArF), and trifluoromethylbenzenes (ArCF3) were discussed in detail to illustrate the role of 19F signals as special fingerprints in assisting the structure identification of fluorine-containing NPS. To the best of our knowledge, this study is the largest evaluation of fluorinated NPS compounds by 19F NMR. The second part of this study dealt with the problems encountered in the 19F quantification procedure and the criteria to be considered for successful quantification by 19F NMR. General high field (HF)- and low field (LF)- 19F qNMR methods for the quantification of fluorinated NPS were established after the thorough discussion of NMR spectrum acquisition and processing parameters such as: transmitter frequency offset (O1P), spin-lattice relaxation time (T1), and different baseline correction methods. The limit of quantifications (LOQs) for HF-19F qNMR varied between 0.1 mg/mL and 0.2 mg/mL, and for LF-19F qNMR varied between 1.0 mg/mL and 2.0 mg/mL. The limit of detections (LODs) for HF-19F qNMR varied between 0.03 mg/mL and 0.06 mg/mL, and for LF-19F qNMR varied between 0.3 mg/mL and 0.6 mg/mL. Finally, the developed methods were applied for the quantification of fluorinated-NPS in seventeen herbal blends, e-liquid, tablet, and powder NPS seizures.


Assuntos
Canabinoides , Flúor , Fármacos do Sistema Nervoso Central , Fentanila , Fluoretos , Flúor/química , Fluorbenzenos , Espectroscopia de Ressonância Magnética/métodos , Fenetilaminas , Pós
15.
J Magn Reson ; 331: 107031, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34391647

RESUMO

This paper presents my recollections on the development of protein structure determination by NMR in solution from 1968 to 1992. The key to success was to identify NMR-accessible parameters that unambiguously determine the spatial arrangement of polypeptide chains. Inspired by work with cyclopeptides, model considerations showed that enforcing short non-bonding interatomic distances imposes «ring closure conditions¼ on polypeptide chains. Given that distances are scalar parameters, this indicated an avenue for studies of proteins in solution, i.e., under the regime of stochastic rotational and translational motions at frequencies in the nanosecond range (Brownian motion), where sharp pictures could not be obtained by photography-related methods. Later-on, we used distance geometry calculations with sets of inter-atomic distances derived from protein crystal structures to confirm that measurements of short proton-proton distances could provide atomic-resolution structures of globular proteins. During the years 1976-1984 the following four lines of research then led to protein structure determination by NMR in solution. First, the development of NMR experiments enabling the use of the nuclear Overhauser effect (NOE) for measurements of interatomic distances between pairs of hydrogen atoms in proteins. Second, obtaining sequence-specific resonance assignment solved the "phase problem" for protein structure determination by NMR. Third, generating and programming novel distance geometry algorithms enabled the calculation of atomic-resolution protein structures from limited sets of distance constraints measured by NMR. Fourth, the introduction of two-dimensional NMR provided greatly improved spectral resolution of the complex spectra of proteins as well as efficient delineation of scalar and dipole-dipole 1H-1H connectivities, thus making protein structure determination in solution viable and attractive.


Assuntos
Algoritmos , Proteínas , Difusão , Espectroscopia de Ressonância Magnética , Conformação Proteica
16.
Forensic Sci Int ; 321: 110718, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33601154

RESUMO

New psychoactive substances (NPS) have become a serious threat to public health in Europe due to their ability to be sold in the street or on the darknet. Regulating NPS is an urgent priority but comes with a number of analytical challenges since they are structurally similar to legal products. A number of analytical techniques can be used for identifying NPS, among which NMR spectroscopy is a gold standard. High field NMR is typically used for structural elucidation in combination with others techniques like GC-MS, Infrared spectroscopy, together with databases. In addition to their strong ability to elucidate molecular structures, high field NMR techniques are the gold standard for quantification without any physical isolation procedure and with a single internal standard. However, high field NMR remains expensive and emerging "benchtop" NMR apparatus which are cheaper and transportable can be considered as valuable alternatives to high field NMR. Indeed, benchtop NMR, which emerged about ten years ago, makes it possible to carry out structural elucidation and quantification of NPS despite the gap in resolution and sensitivity as compared to high field NMR. This review describes recent advances in the field of NMR applied to the characterization of NPS. High-field NMR methods are first described in view of their complementarity with other analytical methods, focusing on both structural and quantitative aspects. The second part of the review highlights how emerging benchtop NMR approaches could act as a game changer in the field of forensics.


Assuntos
Drogas Ilícitas/química , Espectroscopia de Ressonância Magnética/instrumentação , Psicotrópicos/química , Cromatografia Líquida de Alta Pressão , Humanos , Espectrometria de Massas
17.
J Magn Reson ; 300: 95-102, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30721859

RESUMO

We propose here SOFAST-HMBC as a new complementary NMR tool for aromatic side chain assignment of protein samples at natural 13C abundance. The characteristic peak patterns detected in SOFAST-HMBC for each aromatic side chain allow straightforward assignment of all protons and carbons (including quaternary ones) of the aromatic ring, and for tyrosine and phenylalanine, connection to the CB of the aliphatic chain. The performance of SOFAST-HMBC is demonstrated for three small proteins (7-14 kDa) at millimolar sample concentration using modern high-field NMR instruments equipped with cryogenically cooled probes. Despite the low amount of NMR-active 13C nuclei in these samples, 1H-13C multiple-bond correlation spectra of good quality were obtained in reasonable experimental times of typically less than 24 h.


Assuntos
Carbono/química , Ressonância Magnética Nuclear Biomolecular/métodos , Proteínas/química , Aminoácidos/química , Isótopos de Carbono , Hidrocarbonetos Aromáticos , Muramidase/química , Prótons
18.
J Magn Reson ; 263: 164-171, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26778351

RESUMO

Use of high-temperature superconducting (HTS) inner coils in combination with conventional low-temperature superconducting (LTS) outer coils for an NMR magnet, i.e. a LTS/HTS NMR magnet, is a suitable option to realize a high-resolution NMR spectrometer with operating frequency >1GHz. From the standpoint of creating a compact magnet, (RE: Rare earth) Ba2Cu3O7-x (REBCO) HTS inner coils which can tolerate a strong hoop stress caused by a Lorentz force are preferred. However, in our previous work on a first-generation 400MHz LTS/REBCO NMR magnet, the NMR resolution and sensitivity were about ten times worse than that of a conventional LTS NMR magnet. The result was caused by a large field inhomogeneity in the REBCO coil itself and the shielding effect of a screening current induced in that coil. In the present paper, we describe the operation of a modified 400MHz LTS/REBCO NMR magnet with an advanced field compensation technology using a combination of novel ferromagnetic shimming and an appropriate procedure for NMR spectrum line shape optimization. We succeeded in obtaining a good NMR line shape and 2D NOESY spectrum for a lysozyme aqueous sample. We believe that this technology is indispensable for the realization of a compact super-high-field high-resolution NMR.

19.
J Magn Reson ; 249: 38-48, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25462945

RESUMO

High-temperature superconductors (HTS) are the key technology to achieve super-high magnetic field nuclear magnetic resonance (NMR) spectrometers with an operating frequency far beyond 1GHz (23.5T). (RE)Ba2Cu3O7-x (REBCO, RE: rare earth) conductors have an advantage over Bi2Sr2Ca2Cu3O10-x (Bi-2223) and Bi2Sr2CaCu2O8-x (Bi-2212) conductors in that they have very high tensile strengths and tolerate strong electromagnetic hoop stress, thereby having the potential to act as an ultra-compact super-high field NMR magnet. As a first step, we developed the world's first NMR magnet comprising an inner REBCO coil and outer low-temperature superconducting (LTS) coils. The magnet was successfully charged without degradation and mainly operated at 400MHz (9.39T). Technical problems for the NMR magnet due to screening current in the REBCO coil were clarified and solved as follows: (i) A remarkable temporal drift of the central magnetic field was suppressed by a current sweep reversal method utilizing ∼10% of the peak current. (ii) A Z2 field error harmonic of the main coil cannot be compensated by an outer correction coil and therefore an additional ferromagnetic shim was used. (iii) Large tesseral harmonics emerged that could not be corrected by cryoshim coils. Due to those harmonics, the resolution and sensitivity of NMR spectra are ten-fold lower than those for a conventional LTS NMR magnet. As a result, a HSQC spectrum could be achieved for a protein sample, while a NOESY spectrum could not be obtained. An ultra-compact 1.2GHz NMR magnet could be realized if we effectively take advantage of REBCO conductors, although this will require further research to suppress the effect of the screening current.

20.
J Pharm Biomed Anal ; 84: 293-308, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22985529

RESUMO

In the course of exploring the possibilities of developing a new, improved process at Gedeon Richter for the production of the "bisindole" alkaloids vinblastine (VLB) and vincristine (VCR), some novel VLB/VCR-related trace impurities were detected by analytical HPLC. Following isolation by preparative HPLC, a combination of 1D and 2D ultra high-field NMR and high-resolution (HR) (LC-)MS/MS studies allowed the structural identification and complete spectral characterization of several hitherto unpublished VLB/VCR-analogue impurities. Since the impurities could not be isolated in entirely pure forms and were available only in minute, mass-limited quantities, accessing the spectral information needed for their ab initio structure determination was met with various practical difficulties. Successful structure determination therefore relied heavily on the availability and use of detailed and definitive spectral data for both VLB and VCR. In particular, the utilization of detailed (1)H, (13)C, and (15)N NMR assignments as well as (1)H-(1)H, (1)H-(13)C and (1)H-(15)N spin-spin connectivities pertaining to different solvents for VLB/VCR base and sulphate salt was required. Although NMR studies on VLB base and other bisindoles were reported earlier in the literature, an NMR characterization of VLB and VCR under the above-mentioned circumstances and using ultra-high field instrumentation is either scarcely available or entirely lacking, therefore the necessary data had to be obtained in-house. Likewise, a modern tandem HR-ESI-MS/MS(n) fragmentation study of VLB and VCR has not been published yet. In the present paper we therefore give a thorough NMR and MS characterization of VLB and VCR specifically with a view to filling this void and to provide sufficiently extensive and solid reference data for the structural investigation of the aforementioned VLB/VCR impurities. Besides being scientifically relevant in its own right, the disclosed data should be useful for anyone interested in VLB/VCR-related molecules at a structural level.


Assuntos
Contaminação de Medicamentos , Espectroscopia de Ressonância Magnética/métodos , Espectrometria de Massas em Tandem/métodos , Vimblastina/química , Vincristina/química , Cromatografia Líquida de Alta Pressão/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa