Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.282
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 120(51): e2315824120, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38096418

RESUMO

Adherence to medication plays a crucial role in the effective management of chronic diseases. However, patients often miss their scheduled drug administrations, resulting in suboptimal disease control. Therefore, we propose an implantable device enabled with automated and precisely timed drug administration. Our device incorporates a built-in mechanical clock movement to utilize a clockwork mechanism, i.e., a periodic turn of the hour axis, enabling automatic drug infusion at precise 12-h intervals. The actuation principle relies on the sophisticated design of the device, where the rotational movement of the hour axis is converted into potential mechanical energy and is abruptly released at the exact moment for drug administration. The clock movement can be charged either automatically by mechanical agitations or manually by winding the crown, while the device remains implanted, thereby enabling the device to be used permanently without the need for batteries. When tested using metoprolol, an antihypertensive drug, in a spontaneously hypertensive animal model, the implanted device can deliver drug automatically at precise 12-h intervals without the need for further attention, leading to similarly effective blood pressure control and ultimately, prevention of ventricular hypertrophy as compared with scheduled drug administrations. These findings suggest that our device is a promising alternative to conventional methods for complex drug administration.


Assuntos
Fontes de Energia Elétrica , Animais , Humanos , Preparações Farmacêuticas
2.
Clin Microbiol Rev ; 37(2): e0010423, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38506553

RESUMO

SUMMARYImplant-associated infections (IAIs) pose serious threats to patients and can be associated with significant morbidity and mortality. These infections may be difficult to diagnose due, in part, to biofilm formation on device surfaces, and because even when microbes are found, their clinical significance may be unclear. Despite recent advances in laboratory testing, IAIs remain a diagnostic challenge. From a therapeutic standpoint, many IAIs currently require device removal and prolonged courses of antimicrobial therapy to effect a cure. Therefore, making an accurate diagnosis, defining both the presence of infection and the involved microorganisms, is paramount. The sensitivity of standard microbial culture for IAI diagnosis varies depending on the type of IAI, the specimen analyzed, and the culture technique(s) used. Although IAI-specific culture-based diagnostics have been described, the challenge of culture-negative IAIs remains. Given this, molecular assays, including both nucleic acid amplification tests and next-generation sequencing-based assays, have been used. In this review, an overview of these challenging infections is presented, as well as an approach to their diagnosis from a microbiologic perspective.


Assuntos
Técnicas Microbiológicas , Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Técnicas Microbiológicas/métodos , Bactérias/isolamento & purificação , Bactérias/classificação , Bactérias/genética , Laboratórios Clínicos , Técnicas de Diagnóstico Molecular/métodos
3.
Circulation ; 150(5): 350-361, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38940005

RESUMO

BACKGROUND: Current estimates of atrial fibrillation (AF)-associated mortality rely on claims- or clinical-derived diagnoses of AF, limit AF to a binary entity, or are confounded by comorbidities. The objective of the present study is to assess the association between device-recognized AF and mortality among patients with cardiac implantable electronic devices capable of sensitive and continuous atrial arrhythmia detection. Secondary outcomes include relative mortality among cohorts with no AF, paroxysmal AF, persistent AF, and permanent AF. METHODS: Using the deidentified Optum Clinformatics US claims database (2015 to 2020) linked to the Medtronic CareLink database, we identified individuals with a cardiac implantable electronic device who transmitted data ≥6 months after implantation. AF burden was assessed during the first 6 months after implantation (baseline period). Subsequent mortality, assessed from claims data, was compared between patients with and without AF, with adjustment for age, geographic region, insurance type, Charlson Comorbidity Index, and implantation year. RESULTS: Of 21 391 patients (age, 72.9±10.9 years; 56.3% male) analyzed, 7798 (36.5%) had device-recognized AF. During a mean of 22.4±12.9 months (median, 20.1 [12.8-29.7] months) of follow-up, the overall incidence of mortality was 13.5%. Patients with AF had higher adjusted all-cause mortality than patients without AF (hazard ratio, 1.29 [95% CI, 1.20-1.39]; P<0.001). Among those with AF, patients with nonparoxysmal AF had the greatest risk of mortality (persistent AF versus paroxysmal AF: hazard ratio, 1.36 [95% CI, 1.18-1.58]; P<.001; permanent AF versus paroxysmal AF: hazard ratio, 1.23 [95% CI, 1.14-1.34]; P<.001). CONCLUSIONS: After adjustment for potential confounding factors, the presence of AF was associated with higher mortality in our cohort of patients with cardiac implantable electronic devices. Among those with AF, nonparoxysmal AF was associated with the greatest risk of mortality.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Humanos , Fibrilação Atrial/mortalidade , Fibrilação Atrial/diagnóstico , Idoso , Masculino , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Marca-Passo Artificial , Fatores de Risco , Bases de Dados Factuais , Estados Unidos/epidemiologia
4.
Circulation ; 149(2): e201-e216, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38047353

RESUMO

The American Heart Association sponsored the first iteration of a scientific statement that addressed all aspects of cardiovascular implantable electronic device infection in 2010. Major advances in the prevention, diagnosis, and management of these infections have occurred since then, necessitating a scientific statement update. An 11-member writing group was identified and included recognized experts in cardiology and infectious diseases, with a career focus on cardiovascular infections. The group initially met in October 2022 to develop a scientific statement that was drafted with front-line clinicians in mind and focused on providing updated clinical information to enhance outcomes of patients with cardiovascular implantable electronic device infection. The current scientific statement highlights recent advances in prevention, diagnosis, and management, and how they may be incorporated in the complex care of patients with cardiovascular implantable electronic device infection.


Assuntos
Cardiologia , Infecções Cardiovasculares , Doenças Transmissíveis , Desfibriladores Implantáveis , Endocardite Bacteriana , Estados Unidos , Humanos , American Heart Association , Doenças Transmissíveis/diagnóstico , Doenças Transmissíveis/epidemiologia , Doenças Transmissíveis/terapia , Endocardite Bacteriana/tratamento farmacológico , Desfibriladores Implantáveis/efeitos adversos
5.
Circulation ; 149(5): 379-390, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-37950738

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy. We sought to compare the occurrence of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and new-onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP. METHODS: The I-CLAS study (International Collaborative LBBAP Study) included patients with left ventricular ejection fraction ≤35% who underwent BVP or LBBAP for cardiac resynchronization therapy between January 2018 and June 2022 at 15 centers. We performed propensity score-matched analysis of LBBAP and BVP in a 1:1 ratio. We assessed the incidence of VT/VF and new-onset AF among patients with no history of AF. Time to sustained VT/VF and time to new-onset AF was analyzed using the Cox proportional hazards survival model. RESULTS: Among 1778 patients undergoing cardiac resynchronization therapy (BVP, 981; LBBAP, 797), there were 1414 propensity score-matched patients (propensity score-matched BVP, 707; propensity score-matched LBBAP, 707). The occurrence of VT/VF was significantly lower with LBBAP compared with BVP (4.2% versus 9.3%; hazard ratio, 0.46 [95% CI, 0.29-0.74]; P<0.001). The incidence of VT storm (>3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% versus 2.5%; P=0.013). Among 299 patients with cardiac resynchronization therapy pacemakers (BVP, 111; LBBAP, 188), VT/VF occurred in 8 patients in the BVP group versus none in the LBBAP group (7.2% versus 0%; P<0.001). In 1194 patients with no history of VT/VF or antiarrhythmic therapy (BVP, 591; LBBAP, 603), the occurrence of VT/VF was significantly lower with LBBAP than with BVP (3.2% versus 7.3%; hazard ratio, 0.46 [95% CI, 0.26-0.81]; P=0.007). Among patients with no history of AF (n=890), the occurrence of new-onset AF >30 s was significantly lower with LBBAP than with BVP (2.8% versus 6.6%; hazard ratio, 0.34 [95% CI, 0.16-0.73]; P=0.008). The incidence of AF lasting >24 hours was also significantly lower with LBBAP than with BVP (0.7% versus 2.9%; P=0.015). CONCLUSIONS: LBBAP was associated with a lower incidence of sustained VT/VF and new-onset AF compared with BVP. This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiological resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Eletrocardiografia
6.
Circulation ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38984417

RESUMO

The rapid technological advancements in cardiac implantable electronic devices such as pacemakers, implantable cardioverter defibrillators, and loop recorders, coupled with a rise in the number of patients with these devices, necessitate an updated clinical framework for periprocedural management. The introduction of leadless pacemakers, subcutaneous and extravascular defibrillators, and novel device communication protocols underscores the imperative for clinical updates. This scientific statement provides an inclusive framework for the periprocedural management of patients with these devices, encompassing the planning phase, procedure, and subsequent care coordinated with the primary device managing clinic. Expert contributions from anesthesiologists, cardiac electrophysiologists, and cardiac nurses are consolidated to appraise current evidence, offer patient and health system management strategies, and highlight key areas for future research. The statement, pertinent to a wide range of health care professionals, underscores the importance of quality care pathways for patient safety, optimal device function, and minimization of hemodynamic disturbances or arrhythmias during procedures. Our primary objective is to deliver quality care to the expanding patient cohort with cardiac implanted electronic devices, offering direction in the era of evolving technologies and laying a foundation for sustained education and practice enhancement.

7.
Circulation ; 149(23): e1239-e1311, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38718139

RESUMO

AIM: The "2024 AHA/ACC/AMSSM/HRS/PACES/SCMR Guideline for the Management of Hypertrophic Cardiomyopathy" provides recommendations to guide clinicians in the management of patients with hypertrophic cardiomyopathy. METHODS: A comprehensive literature search was conducted from September 14, 2022, to November 22, 2022, encompassing studies, reviews, and other evidence on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, the Agency for Healthcare Research and Quality, and other selected databases relevant to this guideline. Additional relevant studies, published through May 23, 2023, during the guideline writing process, were also considered by the writing committee and added to the evidence tables, where appropriate. STRUCTURE: Hypertrophic cardiomyopathy remains a common genetic heart disease reported in populations globally. Recommendations from the "2020 AHA/ACC Guideline for the Diagnosis and Treatment of Patients With Hypertrophic Cardiomyopathy" have been updated with new evidence to guide clinicians.


Assuntos
American Heart Association , Cardiologia , Cardiomiopatia Hipertrófica , Humanos , Cardiologia/normas , Cardiomiopatia Hipertrófica/terapia , Cardiomiopatia Hipertrófica/diagnóstico , Gerenciamento Clínico , Estados Unidos
8.
Annu Rev Biomed Eng ; 26(1): 197-221, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38346276

RESUMO

Insertable biosensor systems are medical diagnostic devices with two primary components: an implantable biosensor within the body and a wearable monitor that can remotely interrogate the biosensor from outside the body. Because the biosensor does not require a physical connection to the electronic monitor, insertable biosensor systems promise improved patient comfort, reduced inflammation and infection risk, and extended operational lifetimes relative to established percutaneous biosensor systems. However, the lack of physical connection also presents technical challenges that have necessitated new innovations in developing sensing chemistries, transduction methods, and communication modalities. In this review, we discuss the key developments that have made insertables a promising option for longitudinal biometric monitoring and highlight the essential needs and existing development challenges to realizing the next generation of insertables for extended-use diagnostic and prognostic devices.


Assuntos
Técnicas Biossensoriais , Desenho de Equipamento , Dispositivos Eletrônicos Vestíveis , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Humanos , Próteses e Implantes , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos
9.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38096587

RESUMO

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Cardiopatia Reumática , Insuficiência da Valva Tricúspide , Humanos , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Cardiopatia Reumática/complicações , Estudos Retrospectivos
10.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38195003

RESUMO

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/epidemiologia , Displasia Arritmogênica Ventricular Direita/terapia , Estudos Retrospectivos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Fatores de Risco , América do Norte/epidemiologia , Europa (Continente)/epidemiologia
11.
Eur Heart J ; 45(7): 510-518, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37624879

RESUMO

BACKGROUND AND AIMS: Atrial fibrillation (AF) is a chronic progressive disorder. Persistent forms of AF are associated with increased rates of thromboembolism, heart failure, and death. Catheter ablation modifies the pathogenic mechanism of AF progression. No randomized studies have evaluated the impact of the ablation energy on progression to persistent atrial tachyarrhythmia. METHODS: Three hundred forty-six patients with drug-refractory paroxysmal AF were enrolled and randomly assigned to contact-force-guided RF ablation (CF-RF ablation, 115), 4 min cryoballoon ablation (CRYO-4, 115), or 2 min cryoballoon ablation (CRYO-2, 116). Implantable cardiac monitors placed at study entry were used for follow-up. The main outcome was the first episode of persistent atrial tachyarrhythmia. Secondary outcomes included atrial tachyarrhythmia recurrence and arrhythmia burden on the implantable monitor. RESULTS: At a median of 944.0 (interquartile range [IQR], 612.5-1104) days, 0 of 115 patients (0.0%) randomly assigned to CF-RF, 8 of 115 patients (7.0%) assigned to CRYO-4, and 5 of 116 patients (4.3%) assigned to CRYO-2 experienced an episode of persistent atrial tachyarrhythmia (P = .03). A documented recurrence of any atrial tachyarrhythmia ≥30 s occurred in 56.5%, 53.9%, and 62.9% of those randomized to CF-RF, CRYO-4, and CRYO-2, respectively; P = .65. Compared with that of the pre-ablation monitoring period, AF burden was reduced by a median of 99.5% (IQR 94.0%, 100.0%) with CF-RF, 99.9% (IQR 93.3%-100.0%) with CRYO-4, and 99.1%% (IQR 87.0%-100.0%) with CRYO-2 (P = .38). CONCLUSIONS: Catheter ablation of paroxysmal AF using radiofrequency energy was associated with fewer patients developing persistent AF on follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Taquicardia , Recidiva , Veias Pulmonares/cirurgia
12.
Eur Heart J ; 45(3): 161-177, 2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-37638967

RESUMO

BACKGROUND AND AIMS: The European Union Medical Device Regulation 2017/745 challenges key stakeholders to follow transparent and rigorous approaches to the clinical evaluation of medical devices. The purpose of this study is a systematic evaluation of published clinical evidence underlying selected high-risk cardiovascular medical devices before and after market access in the European Union (CE-marking) between 2000 and 2021. METHODS: Pre-specified strategies were applied to identify published studies of prospective design evaluating 71 high-risk cardiovascular devices in seven different classes (bioresorbable coronary scaffolds, left atrial appendage occlusion devices, transcatheter aortic valve implantation systems, transcatheter mitral valve repair/replacement systems, surgical aortic and mitral heart valves, leadless pacemakers, subcutaneous implantable cardioverter-defibrillator). The search time span covered 20 years (2000-21). Details of study design, patient population, intervention(s), and primary outcome(s) were summarized and assessed with respect to timing of the corresponding CE-mark approval. RESULTS: At least one prospective clinical trial was identified for 70% (50/71) of the pre-specified devices. Overall, 473 reports of 308 prospectively designed studies (enrolling 97 886 individuals) were deemed eligible, including 81% (251/308) prospective non-randomized clinical trials (66 186 individuals) and 19% (57/308) randomized clinical trials (31 700 individuals). Pre-registration of the study protocol was available in 49% (150/308) studies, and 16% (48/308) had a peer-reviewed publicly available protocol. Device-related adverse events were evaluated in 82% (253/308) of studies. An outcome adjudication process was reported in 39% (120/308) of the studies. Sample size was larger for randomized in comparison to non-randomized trials (median of 304 vs. 100 individuals, P < .001). No randomized clinical trial published before CE-mark approval for any of the devices was identified. Non-randomized clinical trials were predominantly published after the corresponding CE-mark approval of the device under evaluation (89%, 224/251). Sample sizes were smaller for studies published before (median of 31 individuals) than after (median of 135 individuals) CE-mark approval (P < .001). Clinical trials with larger sample sizes (>50 individuals) and those with longer recruitment periods were more likely to be published after CE-mark approval, and were more frequent during the period 2016-21. CONCLUSIONS: The quantity and quality of publicly available data from prospective clinical investigations across selected categories of cardiovascular devices, before and after CE approval during the period 2000-21, were deemed insufficient. The majority of studies was non-randomized, with increased risk of bias, and performed in small populations without provision of power calculations, and none of the reviewed devices had randomized trial results published prior to CE-mark certification.


Assuntos
Sistema Cardiovascular , Substituição da Valva Aórtica Transcateter , Humanos , Coração , Próteses e Implantes , União Europeia
13.
Nano Lett ; 24(28): 8453-8464, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38771649

RESUMO

Material advances in soft bioelectronics, particularly those based on stretchable nanocomposites─functional nanomaterials embedded in viscoelastic polymers with irreversible or reversible bonds─have driven significant progress in translational medical device research. The unique mechanical properties inherent in the stretchable nanocomposites enable stiffness matching between tissue and device, as well as its spontaneous mechanical adaptation to in vivo environments, minimizing undesired mechanical stress and inflammation responses. Furthermore, these properties allow percolative networks of conducting fillers in the nanocomposites to be sustained even under repetitive tensile/compressive stresses, leading to stable tissue-device interfacing. Here, we present an in-depth review of materials strategies, fabrication/integration techniques, device designs, applications, and translational opportunities of nanocomposite-based soft bioelectronics, which feature intrinsic stretchability, self-healability, tissue adhesion, and/or syringe injectability. Among many, applications to brain, heart, and peripheral nerves are predominantly discussed, and translational studies in certain domains such as neuromuscular and cardiovascular engineering are particularly highlighted.


Assuntos
Nanocompostos , Nanocompostos/química , Humanos , Próteses e Implantes , Materiais Biocompatíveis/química , Animais , Polímeros/química , Eletrônica
14.
J Neurosci ; 43(39): 6653-6666, 2023 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-37620157

RESUMO

The impedance is a fundamental electrical property of brain tissue, playing a crucial role in shaping the characteristics of local field potentials, the extent of ephaptic coupling, and the volume of tissue activated by externally applied electrical brain stimulation. We tracked brain impedance, sleep-wake behavioral state, and epileptiform activity in five people with epilepsy living in their natural environment using an investigational device. The study identified impedance oscillations that span hours to weeks in the amygdala, hippocampus, and anterior nucleus thalamus. The impedance in these limbic brain regions exhibit multiscale cycles with ultradian (∼1.5-1.7 h), circadian (∼21.6-26.4 h), and infradian (∼20-33 d) periods. The ultradian and circadian period cycles are driven by sleep-wake state transitions between wakefulness, nonrapid eye movement (NREM) sleep, and rapid eye movement (REM) sleep. Limbic brain tissue impedance reaches a minimum value in NREM sleep, intermediate values in REM sleep, and rises through the day during wakefulness, reaching a maximum in the early evening before sleep onset. Infradian (∼20-33 d) impedance cycles were not associated with a distinct behavioral correlate. Brain tissue impedance is known to strongly depend on the extracellular space (ECS) volume, and the findings reported here are consistent with sleep-wake-dependent ECS volume changes recently observed in the rodent cortex related to the brain glymphatic system. We hypothesize that human limbic brain ECS changes during sleep-wake state transitions underlie the observed multiscale impedance cycles. Impedance is a simple electrophysiological biomarker that could prove useful for tracking ECS dynamics in human health, disease, and therapy.SIGNIFICANCE STATEMENT The electrical impedance in limbic brain structures (amygdala, hippocampus, anterior nucleus thalamus) is shown to exhibit oscillations over multiple timescales. We observe that impedance oscillations with ultradian and circadian periodicities are associated with transitions between wakefulness, NREM, and REM sleep states. There are also impedance oscillations spanning multiple weeks that do not have a clear behavioral correlate and whose origin remains unclear. These multiscale impedance oscillations will have an impact on extracellular ionic currents that give rise to local field potentials, ephaptic coupling, and the tissue activated by electrical brain stimulation. The approach for measuring tissue impedance using perturbational electrical currents is an established engineering technique that may be useful for tracking ECS volume.


Assuntos
Sono REM , Sono , Humanos , Impedância Elétrica , Sono/fisiologia , Sono REM/fisiologia , Encéfalo/fisiologia , Vigília/fisiologia , Hipocampo
15.
Circulation ; 148(3): 241-252, 2023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37459413

RESUMO

BACKGROUND: Black Americans have a higher risk of nonischemic cardiomyopathy (NICM) than White Americans. We aimed to evaluate differences in the risk of tachyarrhythmias among patients with an implantable cardioverter-defibrillator (ICD). METHODS: The study population comprised 3895 ICD recipients in the United States enrolled in primary prevention ICD trials. Outcome measures included ventricular tachyarrhythmia (VTA), atrial tachyarrhythmia (ATA), ICD therapies, VTA burden (using Andersen-Gill recurrent event analysis), death, and the predicted benefit of the ICD. All events were adjudicated blindly. Outcomes were compared between self-reported Black patients versus White patients with cardiomyopathy (ischemic and NICM). RESULTS: Black patients were more likely to be female (35% versus 22%) and younger (57±12 versus 62±12 years) with a higher frequency of comorbidities. In NICM, Black patients had a higher rate of first VTA, fast VTA, ATA, and appropriate and inappropriate ICD therapy (VTA ≥170 bpm, 32% versus 20%; VTA ≥200 bpm, 22% versus 14%; ATA, 25% versus 12%; appropriate therapy, 30% versus 20%; and inappropriate therapy, 25% versus 11%; P<0.001 for all). Multivariable analysis showed that Black patients with NICM experienced a higher risk of all types of arrhythmia or ICD therapy (VTA ≥170 bpm, hazard ratio [HR] 1.71; VTA ≥200 bpm, HR 1.58; ATA, HR 1.87; appropriate therapy, HR 1.62; inappropriate therapy, HR 1.86; P≤0.01 for all), higher burden of tachyarrhythmias or therapies (VTA, HR 1.84; appropriate therapy, HR 1.84; P<0.001 for both), and a higher risk of death (HR 1.92; P=0.014). In contrast, in ischemic cardiomyopathy, the risk of all types of tachyarrhythmia, ICD therapy, or death was similar between Black patients and White patients. Both Black patients and White patients derived a significant and similar benefit from ICD implantation. CONCLUSIONS: Among patients with NICM with an ICD for primary prevention, Black patients compared with White patients had a high risk and burden of VTA, ATA, and ICD therapies with a lower survival rate. Nevertheless, the overall benefit of the ICD was maintained and was similar to that of White patients.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Feminino , Estados Unidos/epidemiologia , Masculino , Brancos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fatores de Risco , Arritmias Cardíacas , Taquicardia Ventricular/terapia , Taquicardia Ventricular/epidemiologia , Prevenção Primária
16.
Circulation ; 147(21): 1568-1578, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-36960730

RESUMO

BACKGROUND: Treatment options for high-risk Brugada syndrome (BrS) with recurrent ventricular fibrillation (VF) are limited. Catheter ablation is increasingly performed but a large study with long-term outcome data is lacking. We report the results of the multicenter, international BRAVO (Brugada Ablation of VF Substrate Ongoing Registry) for treatment of high-risk symptomatic BrS. METHODS: We enrolled 159 patients (median age 42 years; 156 male) with BrS and spontaneous VF in BRAVO; 43 (27%) of them had BrS and early repolarization pattern. All but 5 had an implantable cardioverter-defibrillator for cardiac arrest (n=125) or syncope (n=34). A total of 140 (88%) had experienced numerous implantable cardioverter-defibrillator shocks for spontaneous VF before ablation. All patients underwent a percutaneous epicardial substrate ablation with electroanatomical mapping except for 8 who underwent open-thoracotomy ablation. RESULTS: In all patients, VF/BrS substrates were recorded in the epicardial surface of the right ventricular outflow tract; 45 (29%) patients also had an arrhythmic substrate in the inferior right ventricular epicardium and 3 in the posterior left ventricular epicardium. After a single ablation procedure, 128 of 159 (81%) patients remained free of VF recurrence; this number increased to 153 (96%) after a repeated procedure (mean 1.2±0.5 procedures; median=1), with a mean follow-up period of 48±29 months from the last ablation. VF burden and frequency of shocks decreased significantly from 1.1±2.1 per month before ablation to 0.003±0.14 per month after the last ablation (P<0.0001). The Kaplan-Meier VF-free survival beyond 5 years after the last ablation was 95%. The only variable associated with a VF-free outcome in multivariable analysis was normalization of the type 1 Brugada ECG, both with and without sodium-channel blockade, after the ablation (hazard ratio, 0.078 [95% CI, 0.008 to 0.753]; P=0.0274). There were no arrhythmic or cardiac deaths. Complications included hemopericardium in 4 (2.5%) patients. CONCLUSIONS: Ablation treatment is safe and highly effective in preventing VF recurrence in high-risk BrS. Prospective studies are needed to determine whether it can be an alternative treatment to implantable cardioverter-defibrillator implantation for selected patients with BrS. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04420078.


Assuntos
Síndrome de Brugada , Ablação por Cateter , Desfibriladores Implantáveis , Humanos , Masculino , Adulto , Fibrilação Ventricular , Eletrocardiografia/métodos , Ventrículos do Coração , Síndrome de Brugada/cirurgia , Síndrome de Brugada/complicações , Desfibriladores Implantáveis/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros
17.
Circulation ; 147(9): 718-727, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36335467

RESUMO

BACKGROUND: Hypertrophic cardiomyopathy (HCM) can be associated with an abnormal exercise response. In adults with HCM, abnormal results on exercise stress testing are predictive of heart failure outcomes. Our goal was to determine whether an abnormal exercise response is associated with adverse outcomes in pediatric patients with HCM. METHODS: In an international cohort study including 20 centers, phenotype-positive patients with primary HCM who were <18 years of age at diagnosis were included. Abnormal exercise response was defined as a blunted blood pressure response and new or worsened ST- or T-wave segment changes or complex ventricular ectopy. Sudden cardiac death (SCD) events were defined as a composite of SCD and aborted sudden cardiac arrest. Using Kaplan-Meier survival, competing outcomes, and Cox regression analyses, we analyzed the association of abnormal exercise test results with transplant and SCD event-free survival. RESULTS: Of 724 eligible patients, 630 underwent at least 1 exercise test. There were no major differences in clinical characteristics between those with or without an exercise test. The median age at exercise testing was 13.8 years (interquartile range, 4.7 years); 78% were male and 39% were receiving beta-blockers. A total of 175 (28%) had abnormal test results. Patients with abnormal test results had more severe septal hypertrophy, higher left atrial diameter z scores, higher resting left ventricular outflow tract gradient, and higher frequency of myectomy compared with participants with normal test results (P<0.05). Compared with normal test results, abnormal test results were independently associated with lower 5-year transplant-free survival (97% versus 88%, respectively; P=0.005). Patients with exercise-induced ischemia were most likely to experience all-cause death or transplant (hazard ratio, 4.86 [95% CI, 1.69-13.99]), followed by those with an abnormal blood pressure response (hazard ratio, 3.19 [95% CI, 1.32-7.71]). Exercise-induced ischemia was also independently associated with lower SCD event-free survival (hazard ratio, 3.32 [95% CI, 1.27-8.70]). Exercise-induced ectopy was not associated with survival. CONCLUSIONS: Exercise abnormalities are common in childhood HCM. An abnormal exercise test result was independently associated with lower transplant-free survival, especially in those with an ischemic or abnormal blood pressure response with exercise. Exercise-induced ischemia was also independently associated with SCD events. These findings argue for routine exercise testing in childhood HCM as part of ongoing risk assessment.


Assuntos
Cardiomiopatia Hipertrófica , Teste de Esforço , Masculino , Feminino , Humanos , Estudos de Coortes , Prevalência , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Arritmias Cardíacas/etiologia , Fatores de Risco
18.
Circulation ; 147(9): 759-767, 2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36848410

RESUMO

The notion that the risk of sudden cardiac death (SCD) in patients with heart failure (HF) is declining seems to be gaining traction. Numerous editorials and commentaries have suggested that SCD, specifically arrhythmic SCD, is no longer a significant risk for patients with HF on guideline-directed medical therapy. In this review, we question whether the risk of SCD has indeed declined in HF trials and in the real world. We also explore whether, despite relative risk reductions, the residual SCD risk after guideline-directed medical therapy still suggests a need for implantable cardioverter defibrillator therapy. Among our arguments is that SCD has not decreased in HF trials, nor in the real world. Moreover, we argue that data from HF trials, which have not adhered to guideline-directed device therapy, do not obviate or justify delays to implantable cardioverter defibrillator therapy. In this context, we underline the challenges of translating the findings of HF randomized, controlled trials of guideline-directed medical therapy to the real world. We also make the case for HF trials that adhere to current guideline-directed device therapy so that we can better understand the role of implantable cardioverter defibrillators in chronic HF.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle
19.
Circulation ; 147(10): 812-823, 2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36700426

RESUMO

BACKGROUND: Benefit from cardiac resynchronization therapy (CRT) varies by QRS characteristics; individual randomized trials are underpowered to assess benefit for relatively small subgroups. METHODS: The authors analyzed patient-level data from pivotal CRT trials (MIRACLE [Multicenter InSync Randomized Clinical Evaluation], MIRACLE-ICD [Multicenter InSync ICD Randomized Clinical Evaluation], MIRACLE-ICD II [Multicenter InSync ICD Randomized Clinical Evaluation II], REVERSE [Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction], RAFT [Resynchronization-Defibrillation for Ambulatory Heart Failure], BLOCK-HF [Biventricular Versus Right Ventricular Pacing in Heart Failure Patients with Atrioventricular Block], COMPANION [Comparison of Medical Therapy, Pacing and Defibrillation in Heart Failure], and MADIT-CRT [Multicenter Automatic Defibrillator Implantation Trial - Cardiac Resynchronization Therapy]) using Bayesian Hierarchical Weibull survival regression models to assess CRT benefit by QRS morphology (left bundle branch block [LBBB], n=4549; right bundle branch block [RBBB], n=691; and intraventricular conduction delay [IVCD], n=1024) and duration (with 150-ms partition). The continuous relationship between QRS duration and CRT benefit was also examined within subgroups defined by QRS morphology. The primary end point was time to heart failure hospitalization (HFH) or death; a secondary end point was time to all-cause death. RESULTS: Of 6264 patients included, 25% were women, the median age was 66 [interquartile range, 58 to 73] years, and 61% received CRT (with or without an implantable cardioverter defibrillator). CRT was associated with an overall lower risk of HFH or death (hazard ratio [HR], 0.73 [credible interval (CrI), 0.65 to 0.84]), and in subgroups of patients with QRS ≥150 ms and either LBBB (HR, 0.56 [CrI, 0.48 to 0.66]) or IVCD (HR, 0.59 [CrI, 0.39 to 0.89]), but not RBBB (HR 0.97 [CrI, 0.68 to 1.34]; Pinteraction <0.001). No significant association for CRT with HFH or death was observed when QRS was <150 ms (regardless of QRS morphology) or in the presence of RBBB. Similar relationships were observed for all-cause death. CONCLUSIONS: CRT is associated with reduced HFH or death in patients with QRS ≥150 ms and LBBB or IVCD, but not for those with RBBB. Aggregating RBBB and IVCD into a single "non-LBBB" category when selecting patients for CRT should be reconsidered. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifiers: NCT00271154, NCT00251251, NCT00267098, and NCT00180271.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Feminino , Idoso , Masculino , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Bloqueio de Ramo/complicações , Terapia de Ressincronização Cardíaca/efeitos adversos , Teorema de Bayes , Ensaios Clínicos Controlados Aleatórios como Assunto , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Eletrocardiografia
20.
Circulation ; 148(11): 862-871, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37555345

RESUMO

BACKGROUND: Ventricular arrhythmia is an important cause of mortality in patients with ischemic left ventricular dysfunction. Revascularization with coronary artery bypass graft or percutaneous coronary intervention is often recommended for these patients before implantation of a cardiac defibrillator because it is assumed that this may reduce the incidence of fatal and potentially fatal ventricular arrhythmias, although this premise has not been evaluated in a randomized trial to date. METHODS: Patients with severe left ventricular dysfunction, extensive coronary disease, and viable myocardium were randomly assigned to receive either percutaneous coronary intervention (PCI) plus optimal medical and device therapy (OMT) or OMT alone. The composite primary outcome was all-cause death or aborted sudden death (defined as an appropriate implantable cardioverter defibrillator therapy or a resuscitated cardiac arrest) at a minimum of 24 months, analyzed as time to first event on an intention-to-treat basis. Secondary outcomes included cardiovascular death or aborted sudden death, appropriate implantable cardioverter defibrillator (ICD) therapy or sustained ventricular arrhythmia, and number of appropriate ICD therapies. RESULTS: Between August 28, 2013, and March 19, 2020, 700 patients were enrolled across 40 centers in the United Kingdom. A total of 347 patients were assigned to the PCI+OMT group and 353 to the OMT alone group. The mean age of participants was 69 years; 88% were male; 56% had hypertension; 41% had diabetes; and 53% had a clinical history of myocardial infarction. The median left ventricular ejection fraction was 28%; 53.1% had an implantable defibrillator inserted before randomization or during follow-up. All-cause death or aborted sudden death occurred in 144 patients (41.6%) in the PCI group and 142 patients (40.2%) in the OMT group (hazard ratio, 1.03 [95% CI, 0.82-1.30]; P=0.80). There was no between-group difference in the occurrence of any of the secondary outcomes. CONCLUSIONS: PCI was not associated with a reduction in all-cause mortality or aborted sudden death. In patients with ischemic cardiomyopathy, PCI is not beneficial solely for the purpose of reducing potentially fatal ventricular arrhythmias. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01920048.


Assuntos
Desfibriladores Implantáveis , Disfunção Ventricular Esquerda , Humanos , Masculino , Idoso , Feminino , Volume Sistólico , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Função Ventricular Esquerda , Arritmias Cardíacas/etiologia , Disfunção Ventricular Esquerda/etiologia , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa