Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(24)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38139756

RESUMO

Implantable electrodes represent a groundbreaking advancement in nervous system research, providing a pivotal tool for recording and stimulating human neural activity. This capability is integral for unraveling the intricacies of the nervous system's functionality and for devising innovative treatments for various neurological disorders. Implantable electrodes offer distinct advantages compared to conventional recording and stimulating neural activity methods. They deliver heightened precision, fewer associated side effects, and the ability to gather data from diverse neural sources. Crucially, the development of implantable electrodes necessitates key attributes: flexibility, stability, and high resolution. Graphene emerges as a highly promising material for fabricating such electrodes due to its exceptional properties. It boasts remarkable flexibility, ensuring seamless integration with the complex and contoured surfaces of neural tissues. Additionally, graphene exhibits low electrical resistance, enabling efficient transmission of neural signals. Its transparency further extends its utility, facilitating compatibility with various imaging techniques and optogenetics. This paper showcases noteworthy endeavors in utilizing graphene in its pure form and as composites to create and deploy implantable devices tailored for neural recordings and stimulations. It underscores the potential for significant advancements in this field. Furthermore, this paper delves into prospective avenues for refining existing graphene-based electrodes, enhancing their suitability for neural recording applications in in vitro and in vivo settings. These future steps promise to revolutionize further our capacity to understand and interact with the neural research landscape.


Assuntos
Grafite , Humanos , Estudos Prospectivos , Eletrodos Implantados , Eletrodos , Sistema Nervoso
2.
Biomed Microdevices ; 22(3): 43, 2020 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-32504225

RESUMO

This paper presents a fabrication method for glassy carbon neural electrode arrays that combines 3D printing and chemical pyrolysis technology. The carbon electrodes have excellent biological compatibility and can be used in neural signal recording. A pretreated Si wafer is used as the substrate for 3D printing, and then, stereolithography 3D printing technology is employed to print photosensitive resin into a cone shape. Next, chemical pyrolysis is applied to convert the 3D prints into glassy carbon electrodes and modify the electrochemical performance of the carbon electrodes. Finally, the glassy carbon electrodes are packed with conductive wires and PDMS. The proposed fabrication method simplifies the manufacturing process of carbon materials, and electrodes can be fabricated without the need of deep reactive ion etching (DRIE). The height of the carbon electrodes is 1.5 mm, and the exposure area of the tips is 0.78 mm2, which is convenient for the implantation procedure. The specific capacitance of the glassy carbon arrays is higher than that of a platinum electrode (9.18 mF/cm2 vs 3.32 mF/cm2, respectively), and the impedance at 1 kHz is lower (7.1 kΩ vs 8.8 kΩ). The carbon electrodes were tested in vivo, and they showed excellent performance in neural signal recording. The signal-to-noise ratio of the carbon electrodes is 50.73 ± 6.11, which is higher than that of the Pt electrode (20.15 ± 5.32) under the same testing conditions. The proposed fabrication method of glassy carbon electrodes provides a novel approach to manufacture penetrating electrodes for nerve interfaces in biomedical engineering and microelectromechanical systems.


Assuntos
Interfaces Cérebro-Computador , Carbono/química , Eletrodos Implantados , Vidro/química , Dimetilpolisiloxanos , Condutividade Elétrica , Desenho de Equipamento , Neurônios/citologia , Nylons , Impressão Tridimensional , Razão Sinal-Ruído , Silício/química
3.
Sensors (Basel) ; 16(12)2016 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-27999346

RESUMO

This paper investigates the effects of annealing of the electrodes based on parylene-caulked polydimethylsiloxane (pc-PDMS) in terms of mechanical strength and long-term electrical property. Previously, the electrodes based on pc-PDMS showed a better ability to withstand in vivo environments because of the low water absorption and beneficial mechanical properties of the substrate, compared to native PDMS. Moreover, annealing is expected to even strengthen the mechanical strength and lower the water absorption of the pc-PDMS substrate. To characterize the mechanical strength and water absorption of the annealed pc-PDMS, tensile tests were carried out and infrared (IR) spectra were measured using Fourier transform infrared spectroscopy over a month. The results showed that annealed pc-PDMS had higher mechanical strength and lower water absorption than non-annealed pc-PDMS. Then, electrochemical impedance spectroscopy was measured to evaluate the electrical stability of the electrodes based on annealed pc-PDMS in phosphate-buffered saline solution at 36.5 °C. The impedance magnitude of the electrodes on annealed pc-PDMS was twice higher than that of the electrodes on non-annealed pc-PDMS in the initial days, but the impedance magnitude of the electrodes based on two different substrates converged to a similar value after eight months, indicating that the annealing effects disappear after a certain period of time in a physiological environment.

4.
Adv Mater ; 36(7): e2310365, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38029425

RESUMO

Stroke is the primary cause of disability without effective rehabilitation methods. Emerging brain-machine interfaces offer promise for regulating brain neural circuits and promoting the recovery of brain function disorders. Implantable probes play key roles in brain-machine interfaces, which are subject to two irreconcilable tradeoffs between conductivity and modulus match/transparency. In this work, mechanically interlocked polyrotaxane is incorporated into topological hydrogels to solve the two tradeoffs at the molecular level through the pulley effect of polyrotaxane. The unique performance of the topological hydrogels enables them to acquire brain neural information and conduct neuromodulation. The probe is capable of continuously recording local field potentials for eight weeks. Optogenetic neuromodulation in the primary motor cortex to regulate brain neural circuits and control limb behavior is realized using the probe. Most importantly, optogenetic neuromodulation is conducted using the probe, which effectively reduces the infarct regions of the brain tissue and promotes locomotor function recovery. This work exhibits a significant scientific advancement in the design concept of neural probes for developing brain-machine interfaces and seeking brain disease therapies.


Assuntos
Interfaces Cérebro-Computador , Rotaxanos , Acidente Vascular Cerebral , Humanos , Hidrogéis , Encéfalo/fisiologia , Acidente Vascular Cerebral/terapia
5.
Sci Rep ; 14(1): 16110, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38997318

RESUMO

An implantable electrode based on bioresorbable Mg-Nd-Zn-Zr alloy was developed for next-generation radiofrequency (RF) tissue welding application, aiming to reduce thermal damage and enhance anastomotic strength. The Mg alloy electrode was designed with different structural features of cylindrical surface (CS) and continuous long ring (LR) in the welding area, and the electrothermal simulations were studied by finite element analysis (FEA). Meanwhile, the temperature variation during tissue welding was monitored and the anastomotic strength of welded tissue was assessed by measuring the avulsion force and burst pressure. FEA results showed that the mean temperature in the welding area and the proportion of necrotic tissue were significantly reduced when applying an alternating current of 110 V for 10 s to the LR electrode. In the experiment of tissue welding ex vivo, the maximum and mean temperatures of tissues welded by the LR electrode were also significantly reduced and the anastomotic strength of welded tissue could be obviously improved. Overall, an ideal welding temperature and anastomotic strength which meet the clinical requirement can be obtained after applying the LR electrode, suggesting that Mg-Nd-Zn-Zr alloy with optimal structure design shows great potential to develop implantable electrode for next-generation RF tissue welding application.


Assuntos
Implantes Absorvíveis , Ligas , Eletrodos Implantados , Magnésio , Ligas/química , Magnésio/química , Soldagem/métodos , Análise de Elementos Finitos , Animais , Temperatura , Ondas de Rádio , Desenho de Equipamento
6.
Biosens Bioelectron ; 185: 113265, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33930755

RESUMO

As a severe stage of cancers, peritoneal carcinomatosis should be frequently monitored by means of ascites analysis. Nevertheless, the analysis process is traumatic and time-consuming in clinical practice. In this study, an implantable platinum nanotree microelectrode with a wireless, battery-free and flexible electrochemical patch was developed for in vivo and real-time peritoneal glucose detection to monitor peritoneal carcinomatosis. As the core of implantable microelectrode, platinum trees were synthesized by one-step electrodeposition method and highly sensitive to glucose detection. The platinum nanotree microelectrode was implantable in peritoneal cavity in minimally invasive way. A flexible circuit patch could execute electrochemical test and realize wireless power harvesting and data interaction with a near field communication (NFC)-enabled smartphone. The whole system could detect glucose dynamics in vivo in rat peritoneal cavity. Furthermore, the accuracy of this system was validated in ascites of patients. In this way, the system could offer hassle-free, rapid and minimally invasive opportunities toward peritoneal carcinomatosis monitoring.


Assuntos
Técnicas Biossensoriais , Neoplasias Peritoneais , Animais , Fontes de Energia Elétrica , Humanos , Microeletrodos , Neoplasias Peritoneais/diagnóstico , Platina , Ratos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa