Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.921
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Mol Cell Proteomics ; 23(5): 100760, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38579929

RESUMO

We describe deep analysis of the human proteome in less than 1 h. We achieve this expedited proteome characterization by leveraging state-of-the-art sample preparation, chromatographic separations, and data analysis tools, and by using the new Orbitrap Astral mass spectrometer equipped with a quadrupole mass filter, a high-field Orbitrap mass analyzer, and an asymmetric track lossless (Astral) mass analyzer. The system offers high tandem mass spectrometry acquisition speed of 200 Hz and detects hundreds of peptide sequences per second within data-independent acquisition or data-dependent acquisition modes of operation. The fast-switching capabilities of the new quadrupole complement the sensitivity and fast ion scanning of the Astral analyzer to enable narrow-bin data-independent analysis methods. Over a 30-min active chromatographic method consuming a total analysis time of 56 min, the Q-Orbitrap-Astral hybrid MS collects an average of 4319 MS1 scans and 438,062 tandem mass spectrometry scans per run, producing 235,916 peptide sequences (1% false discovery rate). On average, each 30-min analysis achieved detection of 10,411 protein groups (1% false discovery rate). We conclude, with these results and alongside other recent reports, that the 1-h human proteome is within reach.


Assuntos
Proteoma , Proteômica , Espectrometria de Massas em Tandem , Humanos , Proteoma/análise , Proteômica/métodos , Fatores de Tempo
2.
Nature ; 626(7998): 240-241, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38297049
3.
Nature ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409403
4.
Nature ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38942975
5.
Nature ; 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39333422
6.
7.
Nature ; 626(8000): 920, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38374431
8.
9.
Nature ; 628(8006): 14-15, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38519544
10.
Nature ; 627(8002): 18-19, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38424328
11.
Nature ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38424331
12.
Nature ; 634(8035): 788, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39438752
13.
15.
16.
Nature ; 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39327521
17.
Nature ; 626(7999): 464-465, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38317001
18.
J Synchrotron Radiat ; 31(Pt 4): 698-705, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38900459

RESUMO

During beam time at a research facility, alignment and optimization of instrumentation, such as spectrometers, is a time-intensive task and often needs to be performed multiple times throughout the operation of an experiment. Despite the motorization of individual components, automated alignment solutions are not always available. In this study, a novel approach that combines optimisers with neural network surrogate models to significantly reduce the alignment overhead for a mobile soft X-ray spectrometer is proposed. Neural networks were trained exclusively using simulated ray-tracing data, and the disparity between experiment and simulation was obtained through parameter optimization. Real-time validation of this process was performed using experimental data collected at the beamline. The results demonstrate the ability to reduce alignment time from one hour to approximately five minutes. This method can also be generalized beyond spectrometers, for example, towards the alignment of optical elements at beamlines, making it applicable to a broad spectrum of research facilities.

19.
J Synchrotron Radiat ; 31(Pt 4): 779-790, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38843001

RESUMO

Understanding and controlling the structure and function of liquid interfaces is a constant challenge in biology, nanoscience and nanotechnology, with applications ranging from molecular electronics to controlled drug release. X-ray reflectivity and grazing incidence diffraction provide invaluable probes for studying the atomic scale structure at liquid-air interfaces. The new time-resolved laser system at the LISA liquid diffractometer situated at beamline P08 at the PETRA III synchrotron radiation source in Hamburg provides a laser pump with X-ray probe. The femtosecond laser combined with the LISA diffractometer allows unique opportunities to investigate photo-induced structural changes at liquid interfaces on the pico- and nanosecond time scales with pump-probe techniques. A time resolution of 38 ps has been achieved and verified with Bi. First experiments include laser-induced effects on salt solutions and liquid mercury surfaces with static and varied time scales measurements showing the proof of concept for investigations at liquid surfaces.

20.
Mass Spectrom Rev ; 2023 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-37610153

RESUMO

Mass spectrometry (MS) has become a powerful technique for clinical applications with high sensitivity and specificity. Different from conventional MS diagnosis in laboratory, point-of-care (POC) analyses in clinics require mass spectrometers and analytical procedures to be friendly for novice users and applicable for on-site clinical diagnosis. The recent decades have seen the progress in the development of miniature mass spectrometers, providing a promising solution for clinical POC applications. In this review, we report recent advances of miniature mass spectrometers and their exploration in clinical applications, mainly including the rapid analysis of illegal drugs, on-site monitoring of therapeutic drugs, and detection of biomarkers. With improved analytical performance, miniature mass spectrometers are also expected to apply to more and more clinical applications. Some promising POC analyses that can be performed by miniature mass spectrometers in the future are discussed. Lastly, we also provide our perspectives on the challenges in technical development of miniature mass spectrometers for clinical POC analysis.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa