Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 722
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Diabetologia ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38995399

RESUMO

People with cystic fibrosis (CF) are at risk for dysglycaemia caused by progressive beta cell dysfunction and destruction due to pancreatic exocrine disease and fibrosis. CF-related diabetes (CFRD) is a unique form of diabetes that has distinctive features from both type 1 and type 2 diabetes. Recent advances in diabetes technology may be of particular benefit in this population given the complex, multi-system organ involvement and challenging health issues that people with CFRD often face. This review summarises how diabetes technologies, such as continuous glucose monitors (CGMs) and insulin delivery devices: (1) have improved our understanding of CFRD, including how hyperglycaemia affects clinical outcomes in people with CF; (2) may be helpful in the screening and diagnosis of CFRD; and (3) offer promise for improving the management of CFRD and easing the burden that this diagnosis can add to an already medically complicated patient population.

2.
Diabetologia ; 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38951212

RESUMO

The increasing incidence of type 2 diabetes, which represents 90% of diabetes cases globally, is a major public health concern. Improved glucose management reduces the risk of vascular complications and mortality; however, only a small proportion of the type 2 diabetes population have blood glucose levels within the recommended treatment targets. In recent years, diabetes technologies have revolutionised the care of people with type 1 diabetes, and it is becoming increasingly evident that people with type 2 diabetes can also benefit from these advances. In this review, we describe the current knowledge regarding the role of technologies for people living with type 2 diabetes and the evidence supporting their use in clinical practice. We conclude that continuous glucose monitoring systems deliver glycaemic benefits for individuals with type 2 diabetes, whether treated with insulin or non-insulin therapy; further data are required to evaluate the role of these systems in those with prediabetes (defined as impaired glucose tolerance and/or impaired fasting glucose and/or HbA1c levels between 39 mmol/mol [5.7%] and 47 mmol/mol [6.4%]). The use of insulin pumps seems to be safe and effective in people with type 2 diabetes, especially in those with an HbA1c significantly above target. Initial results from studies exploring the impact of closed-loop systems in type 2 diabetes are promising. We discuss directions for future research to fully understand the potential benefits of integrating evidence-based technology into care for people living with type 2 diabetes and prediabetes.

3.
Diabetes Metab Res Rev ; 40(3): e3771, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38404019

RESUMO

INTRODUCTION: Insulin requirement in women with Type 1 diabetes (T1DM) changes throughout pregnancy. The aim of this study was to determine the total change in insulin requirements and the effect of gestational weight gain (GWG) and pre-gestational BMI on insulin requirements during pregnancy in women with T1DM treated with continuous subcutaneous insulin infusion and continuous glucose monitoring. METHODS: This historical cohort study included all consecutive women with T1DM who were monitored during pregnancy at the high-risk pregnancy clinic at a tertiary medical center during April 2011-April 2019. One Way Repeated Measures ANOVA with Bonferroni adjustment was conducted to compare the effects of gestational age on insulin requirements and a Two Way Repeated Measures ANOVA was employed to test for the interaction between gestational age intervals and maternal BMI and GWG. RESULTS: Data regarding insulin requirements of 185 pregnancies were included in the analyses. There was a significant effect of gestational age on total insulin (Wilks' Lambda = 0.34, F(6,14) = 4.52, p = 0.009), basal insulin (Wilks' Lambda = 0.41, F(6,14) = 3.30, p = 0.031) and bolus insulin (Wilks' Lambda = 0.43, F(6,14) = 3.02, p = 0.041). Total insulin/kg requirements increased by 5.5% from 13-20 weeks to 20-26 weeks, 19% from 20-26 weeks to 26-33 weeks, and 17.4% from 26 to 33 weeks to delivery (p for trend = 0.009). Overall, insulin requirements increased by 42.1% from conception to delivery (p < 0.01). There was no significant main effect of maternal BMI or GWG on insulin requirements. CONCLUSIONS: There is a significant increase in insulin requirements per kg during pregnancy in women with T1DM who were treated with an insulin pump.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Gestacional , Gravidez , Feminino , Humanos , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Estudos de Coortes , Automonitorização da Glicemia , Glicemia , Insulina Regular Humana , Índice de Massa Corporal , Resultado da Gravidez , Estudos Retrospectivos
4.
J Gen Intern Med ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587726

RESUMO

BACKGROUND: Inpatient use of insulin pump therapy has been increasing due to greater availability of this technology, however there is a paucity of research that investigates glycemic control of inpatient insulin pump users. OBJECTIVE: To compare the glycemic control of hospitalized patients with type 1 diabetes (T1D) who used insulin pump vs. multiple daily injections (MDI). DESIGN: Retrospective chart review. PARTICIPANTS: Patients with T1D who were hospitalized between January 1, 2017, and December 31, 2019, in an academic medical center in the New York metropolitan area. MAIN MEASURES: Patients were categorized into three groups based on their method of insulin administration: "pump only" group used insulin pump exclusively, "MDI only" group used MDI only, and "intermittent pump" group used a combination of both methods. The primary endpoints are mean blood glucose, rates of hypoglycemic events (blood glucose < 70 mg/dL), and rates of hyperglycemic events (blood glucose > 250 mg/dL). Separate multivariable Poisson regressions were performed to determine the association between the type of insulin administration and rate outcomes (i.e., rate of hypoglycemic events and rate of hyperglycemic events). RESULTS: The study included 78 patients with a mean age of 51, who were mostly male (54%), and white (72%). The average proportion of glucose measurements that were hyperglycemic for the "pump only", "MDI only", and "intermittent pump" groups were 0.11 (SD = 0.11), 0.25 (SD = 0.19), and 0.24 (SD = 0.25), respectively. The "pump only" group has a significantly lower proportion of hyperglycemic events as compared to the "MDI only" group (p = 0.0227). CONCLUSIONS: In this sample, patients who exclusively used their insulin pump while inpatient had a lower rate of hyperglycemic events than patients who used MDI only; suggesting that select patients can safely continue their insulin pump therapy in the inpatient setting.

5.
Curr Diab Rep ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38842632

RESUMO

PURPOSE OF REVIEW: There have been many developments in diabetes technology in recent years, with continuous glucose monitoring (CGM), insulin pump therapy (CSII) and automated insulin delivery (AID) becoming progressively accepted in outpatient diabetes care. However, the use of such advanced diabetes technology in the inpatient setting is still limited for several reasons, including logistical challenges and staff training needs. On the other hand, hospital settings with altered diet and stress-induced hyperglycemia often pose challenges to tight glycemic control using conventional treatment tools. Integrating smarter glucose monitoring and insulin delivery devices into the increasingly technical hospital environment could reduce diabetes-related morbidity and mortality. This narrative review describes the most recent literature on the use of diabetes technology in the hospital and suggests avenues for further research. RECENT FINDINGS: Advanced diabetes technology has the potential to improve glycemic control in hospitalized people with and without diabetes, and could add particular value in certain conditions, such as nutrition therapy or perioperative management. Taken together, CGM allows for more accurate and patient-friendly follow-up and ad hoc titration of therapy. AID may also provide benefits, including improved glycemic control and reduced nursing workload. Before advanced diabetes technology can be used on a large scale in the hospital, further research is needed on efficacy, accuracy and safety, while implementation factors such as cost and staff training must also be overcome.

6.
Curr Diab Rep ; 24(5): 85-95, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38421505

RESUMO

PURPOSE OF REVIEW: Diabetes technology has been continuously evolving. Current versions of continuous glucose monitors (CGM) use minimally invasive designs, monitor glucose values with high accuracy, and can be used to guide insulin dosing. Extensive evidence supports the use of diabetes technology for monitoring and insulin administration in people with type 1 diabetes. However, there is emerging evidence for people with type 2 diabetes. In this review, we present the different technological devices used to monitor glucose and deliver insulin and the evidence supporting their use in people with type 2 diabetes. RECENT FINDINGS: The use of CGMs in people with type 2 diabetes treated with insulin or non-insulin therapies has been associated with improvements in glycemic control and time spent in hypoglycemia. Smart insulin pens and smart connected devices are options to track compliance and guide insulin delivery in people who do not require insulin pump therapy. Mechanical patch pumps can be used to reduce the burden of multiple daily insulin injections. Automated insulin delivery algorithms improve glycemic control without an increase in hypoglycemia. The use of technology in the management of type 2 diabetes generates glycemic data previously inaccessible, reduces barriers for insulin initiation, improves glycemic control, tracks adherence to therapy, and improves user satisfaction.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 2 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Automonitorização da Glicemia/métodos , Hipoglicemiantes/uso terapêutico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Insulina/uso terapêutico , Glicemia/análise , Controle Glicêmico/métodos
7.
Diabetes Obes Metab ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39010293

RESUMO

AIM: This study aims to provide a comprehensive overview of real-world evidence pertaining to disparities in the utilization of continuous glucose monitors (CGMs)/insulin pumps to highlight potential evidentiary gaps and discern emerging themes from the literature. MATERIALS AND METHODS: A systematic review of published manuscripts and abstracts was conducted from: MEDLINE, EMBASE, Nursing and Allied Health, Web of Science and CINHAL. Attributes related to patients, outcomes, interventions (CGMs/pumps/both) and study type were captured. In addition, factors associated with disparities in device utilization were examined. RESULTS: Thirty-six studies were included in the final analysis; the studies predominantly focused on people living with type 1 diabetes. Only two studies included individuals with type 2 diabetes. Almost two-thirds of the studies reported outcomes associated with disparities (e.g. glycated haemoglobin, diabetic ketoacidosis, resource utilization). Most studies highlighted disparities across race, ethnicity and insurance type. Evidentiary gaps were identified, particularly in the evidence for people with type 2 diabetes, the continuation of CGM/pump use and limited studies addressing disparities among Native Americans/American Indians. CONCLUSION: This study reveals critical disparities in diabetes technology use across race, ethnicity and insurance type, particularly among people with type 1 diabetes. Evidentiary gaps assessing disparities in diabetes technology use persist, particularly concerning people with type 2 diabetes, Native American/American Indian and LGBTQ+ populations, and in outcomes related to continuation of use. Social and digital determinants of health, such as income, transportation, residential location and technological literacy, are crucial to achieving equitable access. Future research should focus on the patient journey to identify opportunities for equitable access to diabetes technology as its use grows.

8.
Diabetes Obes Metab ; 26(8): 3078-3087, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38698647

RESUMO

AIM: To evaluate gastric emptying (GE) and the glycaemic response to a 75-g oral glucose load in newly diagnosed, treatment-naïve Han Chinese with type 2 diabetes (T2D) before insulin pump therapy, after 4 weeks of insulin pump therapy, and 12-15 months after insulin pump therapy. MATERIALS AND METHODS: Twenty participants with T2D (baseline glycated haemoglobin [± SD] 10.7% [± 1.2%] 93 [± 10] mmol/mol) ingested a 75-g glucose drink containing 150 mg 13C-acetate, to determine the gastric half-emptying time, and underwent assessment of plasma glucose and serum insulin, C-peptide and glucagon-like peptide-1 (GLP-1) over 180 min before and after 4 weeks of insulin pump therapy (discontinued for 48 h before re-assessment). Data were compared to those in 19 healthy participants matched for sex and age. After 12-15 months, GE was re-measured in 14 of the T2D participants. RESULTS: At baseline, participants with T2D exhibited substantially augmented fasting and post-glucose glycaemia, diminished insulin secretion, and more rapid GE (p < 0.05 each), but comparable GLP-1, compared to healthy participants. Following insulin pump therapy, insulin secretion increased, GLP-1 secretion was attenuated, fasting and post-glucose glycaemia were lower, and GE was slowed (p < 0.05 each). The slowing of GE in T2D participants was sustained over 12-15 months of follow-up. CONCLUSIONS: In newly diagnosed Han Chinese with T2D, GE is often accelerated despite poor glycaemic control and is slowed by short-term insulin pump therapy. The effect on GE is maintained for at least 12 months.


Assuntos
Glicemia , Diabetes Mellitus Tipo 2 , Esvaziamento Gástrico , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/sangue , Masculino , Feminino , Pessoa de Meia-Idade , Esvaziamento Gástrico/efeitos dos fármacos , Glicemia/análise , Glicemia/metabolismo , Insulina/administração & dosagem , Hipoglicemiantes/administração & dosagem , China , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/metabolismo , Adulto , Povo Asiático , Peptídeo 1 Semelhante ao Glucagon/administração & dosagem , Peptídeo C/sangue , Secreção de Insulina/efeitos dos fármacos , Teste de Tolerância a Glucose , População do Leste Asiático
9.
Diabetes Obes Metab ; 26(1): 78-84, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37743832

RESUMO

AIM: To compare open-source AndroidAPS (AAPS) and commercially available Control-IQ (CIQ) automated insulin delivery (AID) systems in a prospective, open-label, single-arm clinical trial. METHODS: Adults with type 1 diabetes who had been using AAPS by their own decision entered the first 3-month AAPS phase then were switched to CIQ for 3 months. The results of this treatment were compared with those after the 3-month AAPS phase. The primary endpoint was the change in time in range (% TIR; 70-80 mg/dL). RESULTS: Twenty-five people with diabetes (mean age 34.32 ± 11.07 years; HbA1c 6.4% ± 3%) participated in this study. CIQ was comparable with AAPS in achieving TIR (85.72% ± 7.64% vs. 84.24% ± 8.46%; P = .12). Similarly, there were no differences in percentage time above range (> 180 and > 250 mg/dL), mean sensor glucose (130.3 ± 13.9 vs. 128.3 ± 16.9 mg/dL; P = .21) or HbA1c (6.3% ± 2.1% vs. 6.4% ± 3.1%; P = .59). Percentage time below range (< 70 and < 54 mg/dL) was significantly lower using CIQ than AAPS. Even although participants were mostly satisfied with CIQ (63.6% mostly agreed, 9.1% strongly agreed), they did not plan to switch to CIQ. CONCLUSIONS: The CODIAC study is the first prospective study investigating the switch between open-source and commercially available AID systems. CIQ and AAPS were comparable in achieving TIR. However, hypoglycaemia was significantly lower with CIQ.


Assuntos
Diabetes Mellitus Tipo 1 , Insulinas , Adulto , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Glicemia , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Estudos Prospectivos
10.
Diabet Med ; 40(6): e15068, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36786049

RESUMO

AIMS: Insulin pump self-management is important for glycaemic outcomes. We aimed to investigate associations between self-management factors and HbA1c. METHODS: Adult insulin pump users with type 1 diabetes (n = 770) completed an online questionnaire. The latest HbA1c and demographics were extracted from national registries. Associations between HbA1c and self-management (use of advanced features, timing of infusion set change, timing of meal bolus, data-upload and pump settings adjustments) were investigated using backward selected linear regression models. RESULTS: Of the 699 responders eligible for this study, 60% were women; the median age and diabetes duration were 49 and 25 years, respectively. Significant associations with HbA1c were found for changing infusion set every 0-4 days relative to 5-10 days (-5 mmol/mol (-0.4%), p = 0.003), and for never/rarely missing a bolus (-6 mmol/mol (-0.5%), p < 0.001) relative to often missing a bolus. Timing insulin 10-15 min before meal relative to after meal start was also associated with lower HbA1c (-3 mmol/mol (-0.3%), p = 0.023). Self-adjusting pump settings showed the strongest association with lower HbA1c (-6 mmol/mol (-0.6%), p < 0.001) relative to health care professionals doing all adjustments. CONCLUSION: Self-adjusting insulin pump settings, optimal timing and few omissions of meal boluses, and timely change of infusion set are associated with lower HbA1c.


Assuntos
Diabetes Mellitus Tipo 1 , Autogestão , Adulto , Humanos , Feminino , Masculino , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas , Sistemas de Infusão de Insulina , Glicemia , Hipoglicemiantes/uso terapêutico
11.
Diabet Med ; 40(1): e14944, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36004676

RESUMO

AIMS: To explore the association between the use of glycaemic technologies and person-reported outcomes (PROs) in adults with type 1 diabetes (T1D). METHODS: We included T1D and technology publications reporting on PROs since 2014. Only randomised controlled trials and cohort studies that used validated PRO measures (PROMs) were considered. RESULTS: T1D studies reported on a broad range of validated PROMs, mainly as secondary outcome measures. Most studies examined continuous glucose monitoring (CGM), intermittently scanned CGM (isCGM), and the role of continuous subcutaneous insulin infusion (CSII), including sensor-augmented CSII and closed loop systems. Generally, studies demonstrated a positive impact of technology on hypoglycaemia-specific and diabetes-specific PROs, including reduced fear of hypoglycaemia and diabetes distress, and greater satisfaction with diabetes treatment. In contrast, generic PROMs (including measures of health/functional status, emotional well-being, depressive symptoms, and sleep quality) were less likely to demonstrate improvements associated with the use of glycaemic technologies. Several studies showed contradictory findings, which may relate to study design, population and length of follow-up. Differences in PRO findings were apparent between randomised controlled trials and cohort studies, which may be due to different populations studied and/or disparity between trial and real-world conditions. CONCLUSIONS: PROs are usually assessed as secondary outcomes in glycaemic technology studies. Hypoglycaemia-specific and diabetes-specific, but not generic, PROs show the benefits of glycaemic technologies, and deserve a more central role in future studies as well as routine clinical care.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adulto , Humanos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Qualidade de Vida , Tecnologia , Ensaios Clínicos Controlados Aleatórios como Assunto
12.
Am J Obstet Gynecol ; 229(6): 680.e1-680.e8, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37429432

RESUMO

BACKGROUND: Intrapartum glucose management is critical to reducing neonatal hypoglycemia shortly after birth. Although it is known that insulin is required for all pregnant individuals with type 1 diabetes mellitus, the optimal mode of intrapartum glycemic control is not known. OBJECTIVE: This study aimed to compare the effect of intrapartum use of continuous subcutaneous insulin infusion with that of intravenous insulin infusion for glucose management among pregnant individuals with type 1 diabetes mellitus on neonatal blood glucose levels. STUDY DESIGN: This was a randomized controlled trial of pregnant participants with type 1 diabetes mellitus. After written informed consent, participants were randomly allocated to 1 of 2 intrapartum insulin administration strategies: continuation of their continuous subcutaneous insulin infusion or intravenous insulin infusion. The primary outcome was the first neonatal blood glucose level. RESULTS: Between March 2021 and April 2023, 76 participants were approached, and 70 participants were randomized (35 participants in the intravenous insulin infusion group and 35 participants in the continuous subcutaneous insulin infusion group). The groups were similar in terms of age, race/ethnicity, pregravid body mass index, nulliparity, and gestational age at delivery. There was no statistically significant difference in the first neonatal glucose measurement between the 2 groups (50.1±23.4 vs 49.2±22.6; P=.86). In addition, there were no statistically significant differences in any secondary neonatal outcomes. Approximately 57.1% of neonates in the continuous subcutaneous insulin infusion group required either oral, intravenous, or both treatments for hypoglycemia, whereas 51.4% of neonates in the intravenous infusion group required treatment. In both groups, 28.6% of neonates required intravenous treatment for hypoglycemia. CONCLUSION: Pregnant individuals with type 1 diabetes mellitus using either intravenous insulin infusion or continuation of their continuous subcutaneous insulin infusion for intrapartum insulin administration had no difference in the primary outcome of neonatal hypoglycemia. Patients should be given the option of both glycemic management strategies intrapartum.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Gravidez , Recém-Nascido , Feminino , Humanos , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Glicemia , Infusões Intravenosas , Hipoglicemia/induzido quimicamente , Glucose
13.
Expert Opin Emerg Drugs ; 28(1): 1-15, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36896700

RESUMO

INTRODUCTION: Despite therapeutic advances in the field of diabetes management since the discovery of insulin 100 years ago, there are still unmet clinical needs for people with type 1 diabetes mellitus (T1DM). AREAS COVERED: Genetic testing and islet autoantibodies testing allow researchers to design prevention studies. This review discusses the emerging therapy for prevention of T1DM, disease modification therapy in early course of T1DM, and therapies and technologies for established T1DM. We focus on phase 2 clinical trials with promising results, thus avoiding the exhausted list of every new therapy for T1DM. EXPERT OPINION: Teplizumab has demonstrated potential as a preventative agent for individuals at risk prior to the onset of overt dysglycemia. However, these agents are not without side effects, and there are uncertainties on long-term safety. Technological advances have led a substantial influence on quality of life of people suffering from T1DM. There remains variation in uptake of new technologies across the globe. Novel insulins (ultra-long acting), oral insulin, and inhaled insulin attempt to narrow the gap of unmet needs. Islet cell transplant is another exciting field, and stem cell therapy might have potential to provide unlimited supply of islet cells.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/genética , Qualidade de Vida , Insulina/uso terapêutico , Anticorpos Monoclonais Humanizados/uso terapêutico , Hipoglicemiantes/farmacologia , Hipoglicemiantes/uso terapêutico , Ensaios Clínicos Fase II como Assunto
14.
J Sleep Res ; 32(3): e13799, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36495012

RESUMO

The aim of this study was to better characterise whether sleep habits, eating schedule and physical activity in real-life are associated with glycaemic control in patients with type 2 diabetes. A total of 28 patients (aged 60 years [58; 66], 54% female) with type 2 diabetes treated with basal-bolus insulin therapy administered by insulin pumps were analysed. Glycaemic data measured by Flash Glucose Monitor System, physical activity and sleep data measured by accelerometer, and meal schedules were simultaneously collated with insulin pump administration data, for 7 days in real-life. Their respective impact on the time spent in target, in hypoglycaemia, in hyperglycaemia and on glycaemic variability was evaluated. Multiple regressions showed that the total daily dose of meal boluses of insulin was inversely associated with the coefficient of variation (CV; coefficient ß = -0.073; 95% confidence interval: -0.130, -0.015; p = 0.016), as well as sleep duration. The higher the sleep duration, the lower the glycaemic variability (coefficient ß = -0.012; 95% confidence interval: -0.023, -0.002; p = 0.027). The mean 7 days physical activity of the subjects was very low and was not associated with glycaemic control on the 7 days mean values. However, days with at least 1 hr spent in physical activity higher than 1.5 METs were associated with less glycaemic variability that same day. This real-life observation highlights the importance of sufficient sleep duration and regular physical activity to lessen the glycaemic variability of patients with type 2 diabetes.


Assuntos
Diabetes Mellitus Tipo 2 , Hipoglicemia , Humanos , Feminino , Masculino , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Hipoglicemia/tratamento farmacológico , Glicemia , Sono
15.
Diabetes Obes Metab ; 25 Suppl 2: 3-20, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36949618

RESUMO

The global prevalence and increasing incidence rates of type 2 diabetes (T2D) have rippling effects on healthcare costs and diminishing quality of life. Despite advances in technology, continuous subcutaneous insulin infusion (CSII), or insulin pump therapy, is rarely being recommended by healthcare professionals and is underutilized in T2D management. This review analyses the available literature on CSII use in T2D patients. In addition, it discusses which groups of patients may benefit from CSII, identifies potential challenges associated with CSII use, and suggests future directions for research to expand the applicability of this technology to the broader T2D population.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/induzido quimicamente , Hipoglicemiantes/efeitos adversos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Qualidade de Vida , Análise Custo-Benefício , Insulina/efeitos adversos
16.
Diabetes Obes Metab ; 25(6): 1624-1631, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36792920

RESUMO

AIM: To investigate sleep apnoea prevalence, factors influencing severity, and associations between sleep apnoea severity and micro-/macrovascular complications in a large population of patients with type 1 diabetes. MATERIALS AND METHODS: This French multicentre prospective cohort study was conducted between July 2016 and June 2020. Adults with type 1 diabetes using an insulin pump were eligible. Home care provider nurses collected demographic and clinical data and set up oximetry to determine the oxygen desaturation index (ODI). No, mild-moderate and severe sleep apnoea were defined as ODI <15 events/h, 15 to <30 events/h and ≥30 events/h, respectively. Univariate and multivariate analyses were performed to identify factors associated with sleep apnoea, and associations between sleep apnoea severity and micro-/macrovascular complications were determined using logistic regression. RESULTS: Of 769 participants, 12.4% and 3.4% had mild-to-moderate or severe sleep apnoea, respectively. Factors significantly associated with sleep apnoea on multivariate analysis were age, sex, body mass index (BMI) and hypertension. After adjustment for age, sex and BMI, presence of severe sleep apnoea was significantly associated with macrovascular complications (odds ratio vs. no sleep apnoea: 3.96 [95% confidence interval 1.43-11.11]; P < 0.01), while mild-to-moderate sleep apnoea was significantly associated with presence of diabetic retinopathy (odds ratio 2.09 [95% confidence interval 1.10-3.74]; P < 0.01). CONCLUSION: Sleep apnoea is a significant comorbidity in patients with type 1 diabetes, especially with respect to diabetic complications. This highlights the need for sleep apnoea screening and management in these individuals.


Assuntos
Diabetes Mellitus Tipo 1 , Apneia Obstrutiva do Sono , Adulto , Humanos , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/epidemiologia , Estudos Prospectivos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/diagnóstico , Fatores de Risco , Prevalência , Comorbidade
17.
Diabetes Obes Metab ; 25(11): 3144-3151, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37427768

RESUMO

AIM: To evaluate the glycaemia risk index (GRI) and its association with other continuous glucose monitoring (CGM) metrics after initiation of an automated insulin delivery (AID) system in patients with type 1 diabetes (T1D). MATERIALS AND METHODS: Up to 90 days of CGM data before and after initiation of an AID system from 185 CGM users with T1D were collected. GRI and other CGM metrics were calculated using cgmanalysis R software and were analysed for 24 hours, for both night-time and daytime. GRI values were assigned to five GRI zones: zone A (0-20), B (21-40), C (41-60), D (61-80) and E (81-100). RESULTS: Compared with baseline, GRI and its components decreased significantly after AID initiation (GRI: 48.7 ± 21.8 vs. 29 ± 13; hypoglycaemia component: 2.7 ± 2.8 vs. 1.6 ± 1.7; hyperglycaemia component: 25.3 ± 14.5 vs. 15 ± 8.5; P < .001 for all). The GRI was inversely correlated with time in range before (r = -0.962) and after (r = -0.961) AID initiation (P < .001 for both). GRI was correlated with time above range (before: r = 0.906; after = 0.910; P < .001 for both), but not with time below range (P > .05). All CGM metrics improved after AID initiation during 24 hours, for both daytime and night-time (P < .001 for all). Metrics improved significantly more during night-time than daytime (P < .01). CONCLUSIONS: GRI was highly correlated with various CGM metrics above, but not below target range, both before and after AID initiation.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glicemia , Insulina/efeitos adversos , Automonitorização da Glicemia , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemia/prevenção & controle , Hipoglicemiantes/efeitos adversos
18.
Diabetes Obes Metab ; 25(11): 3212-3222, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37551542

RESUMO

AIMS: To reassess the 6-month efficacy and to assess the 12-month sustained efficacy of the MiniMed™ 780G advanced hybrid closed-loop automated insulin delivery (AID) system compared to multiple daily injections plus intermittently scanned glucose monitoring (MDI+isCGM) in people with type 1 diabetes not meeting glucose targets. METHODS: The ADAPT study was a prospective, multicentre, open-label, randomized control trial in people with type 1 diabetes, with a glycated haemoglobin (HbA1c) concentration of at least 8.0% (64 mmol/mol), on MDI+isCGM therapy. After a 6-month study phase, participants randomized at baseline to MDI+isCGM switched to AID (SWITCH) while the others continued AID therapy (SUSTAIN) for an additional 6 months. The primary endpoint of this continuation phase was the within-group change in mean HbA1c between 6 and 12 months, with superiority in the SWITCH group and noninferiority in the SUSTAIN group (ClinicalTrials.gov: NCT04235504). RESULTS: A total of 39 SWITCH and 36 SUSTAIN participants entered the continuation phase. In the SWITCH group, HbA1c was significantly decreased by -1.4% (95% confidence interval [CI] -1.7% to -1.1%; P < 0.001) from a mean ± SD of 8.9% ± 0.8% (73.9 ± 8.6 mmol/mol) at 6 months to 7.5% ± 0.6% (58.5 ± 6.9 mmol/mol) at 12 months. Mean HbA1c increased by 0.1% (95% CI -0.05% to +0.25%), from 7.3% ± 0.6% (56.5 ± 6.7 mmol/mol) to 7.4% ± 0.8% (57.7 ± 9.1 mmol/mol) in the SUSTAIN group, meeting noninferiority criteria. Three severe hypoglycaemia events occurred in two SWITCH participants during the continuation phase. CONCLUSION: ADAPT study phase glycaemic improvements were reproduced and sustained in the continuation phase, supporting the early adoption of AID therapy in people with type 1 diabetes not meeting glucose targets on MDI therapy.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Hemoglobinas Glicadas , Estudos Prospectivos , Automonitorização da Glicemia , Reprodutibilidade dos Testes , Glicemia , Sistemas de Infusão de Insulina
19.
Diabetes Obes Metab ; 25 Suppl 2: 21-32, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37046364

RESUMO

The use of continuous subcutaneous insulin infusion (CSII) via insulin pumps is today considered standard of care for type 1 diabetes (T1D). Closed-loop systems combining continuous glucose monitoring with automated algorithm-driven insulin delivery have been shown to be safe and efficacious in randomized controlled trials and real-life studies in both paediatric and adult participants with T1D. Implementation of hybrid closed-loop (HCL) systems has shown incremental effectiveness, with further reduction of hypoglycaemia and hyperglycaemia. Although less extensively studied in type 2 diabetes (T2D), insulin pumps have demonstrated their effectiveness in glucose control, along with a reduction in need for insulin and a neutral effect on weight. Recent studies have also shown promising results with the use of HCL systems in T2D. Cost-effectiveness studies in both T1D and T2D have shown that pump use is cost-effective in several countries, leading to improvements in quality-adjusted life-years. Insulin pumps are currently reimbursed for T1D in many European countries, but in only a few for individuals with T2D. HCL systems are to be evaluated in future trials performed in T2D to compare their incremental efficacy and cost-effectiveness in comparison with available intensification tools which include multiple daily insulin injections, metformin, sodium-glucose cotransporter-2 inhibitors and glucagon-like peptide-1 receptor agonists. There is a need for updated guidelines for the use of CSII and HCL in individuals living with T2D based on the emerging evidence, with identification of and recommendations for the people who would benefit the most, which would eventually form a basis for reimbursement and health policies.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Inibidores do Transportador 2 de Sódio-Glicose , Adulto , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Análise Custo-Benefício , Automonitorização da Glicemia/métodos , Glicemia , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Tecnologia , Hipoglicemiantes/uso terapêutico
20.
Diabetes Obes Metab ; 25(3): 878-888, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36482870

RESUMO

AIMS: To profile acute glycaemic dynamics during graded exercise testing (GXT) and explore the influence of glycaemic indicators on the physiological responses to GXT in adults with type 1 diabetes using insulin pump therapy. METHODS: This was a retrospective analysis of pooled data from four clinical trials with identical GXT protocols. Data were obtained from 45 adults with type 1 diabetes using insulin pumps [(30 females); haemoglobin A1c 59.5 ± 0.5 mmol/mol (7.6 ± 1.0%); age 49.7 ± 13.0 years; diabetes duration 31.2 ± 13.5 years; V̇O2peak 29.5 ± 8.0 ml/min/kg]. Integrated cardiopulmonary variables were collected continuously via spiroergometry. Plasma glucose was obtained every 3 min during GXT as well as the point of volitional exhaustion. Data were assessed via general linear modelling techniques with age and gender adjustment. Significance was accepted at p ≤ .05. RESULTS: Despite increasing duration and intensity, plasma glucose concentrations remained similar to rest values (8.8 ± 2.3 mmol/L) throughout exercise (p = .419) with an overall change of +0.3 ± 1.1 mmol/L. Starting glycaemia bore no influence on subsequent GXT responses. Per 1% increment in haemoglobin A1c there was an associated decrease in V̇O2peak of 3.8 ml/min/kg (p < .001) and powerpeak of 0.33 W/kg (p < .001) concomitant with attenuations in indices of peripheral oxygen extraction [(O2 pulse) -1.2 ml/beat, p = .023]. CONCLUSION: In adults with long-standing type 1 diabetes using insulin pump therapy, circulating glucose remains stable during a graded incremental cycle test to volitional exhaustion. Glycaemic indicators are inversely associated with aerobic rate, oxygen economy and mechanical output across the exercise intensity spectrum. An appreciation of these nexuses may help guide appropriate decision making for optimal exercise management strategies.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Glicemia/análise , Teste de Esforço , Hemoglobinas Glicadas , Insulina/uso terapêutico , Oxigênio/uso terapêutico , Estudos Retrospectivos , Masculino
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa