Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.651
Filtrar
Mais filtros

Eixos temáticos
Tipo de documento
Intervalo de ano de publicação
1.
BMC Microbiol ; 24(1): 170, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760711

RESUMO

BACKGROUND: Intra-oral halitosis (IOH) is bad breath produced locally by the mouth in addition to systemic diseases and is one of the main causes of interpersonal communication and psychological disorders in modern society. However, current treatment modalities still only alleviate IOH and do not eradicate it. Therefore, based on the differential performance of oral microecology in IOH patients, we propose a microbiota transplantation treatment aimed at restoring oral microecological balance and analyze its feasibility by oral flora colonization test in Wistar rats. OBJECTIVE: Saliva flora samples were collected from IOH patients and healthy subjects to analyze the feasibility of oral microbiota transplantation (OMT) for the treatment of IOH by the Wistar rat oral flora colonization test. METHODS: Seven patients with IOH who visited the First Affiliated Hospital of Xinjiang Medical University from June 2017 to June 2022 with the main complaint of halitosis and three healthy subjects were randomly selected. A Halimeter portable breath detector was used to record breath values and collect saliva flora samples. Sixteen SPF-grade male Wistar rats were housed in the Animal Experiment Center of Xinjiang Medical University and randomly divided into an experimental group (Group E) and a control group (Group C) for the oral flora colonization test. Species composition and associated metabolic analysis of oral flora during the Wistar rat test using 16SrRNA sequencing technology and PICRUSt metabolic analysis. Also, the changes in the breath values of the rats were recorded during the test. RESULTS: The proportion of Porphyromonas, Fusobacterium, Leptotrichia, and Peptostreptococcus was significantly higher in group E compared to group C after colonization of salivary flora of IOH patients (all P < 0.05), and the abundance with Gemella was zero before colonization, while no colonization was seen in group C after colonization compared to baseline. PICRUSt metabolic analysis also showed significantly enhanced IOH-related metabolic pathways after colonization in group E (all P < 0.05), as well as significantly higher breath values compared to baseline and group C (all P < 0.0001). After colonization by salivary flora from healthy subjects, group E rats showed a decrease in the abundance of associated odor-causing bacteria colonization, a reduction in associated metabolism, and a significant decrease in breath values. In contrast, group C also showed differential changes in flora structure and breath values compared to baseline after salivary flora colonization of IOH patients. CONCLUSIONS: OMT for IOH is a promising green treatment option, but the influence of environmental factors and individual differences still cannot be ignored.


Assuntos
Estudos de Viabilidade , Halitose , Microbiota , Boca , Ratos Wistar , Saliva , Animais , Halitose/microbiologia , Halitose/terapia , Masculino , Ratos , Humanos , Saliva/microbiologia , Boca/microbiologia , Bactérias/classificação , Bactérias/isolamento & purificação , Bactérias/genética , Adulto , Feminino , RNA Ribossômico 16S/genética , Pessoa de Meia-Idade
2.
Mov Disord ; 39(6): 945-954, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38698639

RESUMO

BACKGROUND: Double-blind studies have demonstrated that motor complications in Parkinson's disease (PD) can be reduced with continuous delivery of levodopa. The DopaFuse system is a novel, intraoral micropump that attaches to a retainer and uses a propellant to deliver levodopa/carbidopa (LD/CD) continuously into the mouth. OBJECTIVES: Evaluate the safety, pharmacokinetics, and efficacy of LD/CD delivered via the DopaFuse system compared to treatment with intermittent doses of standard oral LD/CD in PD patients with motor fluctuations. METHODS: This was a 2-week, open-label study (NCT04778176) in 16 PD patients treated with ≥4 levodopa doses/day and experiencing motor fluctuations. On Day 1 (clinic setting) patients received their usual dose of standard LD/CD; DopaFuse therapy was initiated on Day 2, and on Day 3 patients received DopaFuse plus a morning oral LD/CD dose. Patients returned home on Days 4-14 and returned for in-clinic assessment on Day 15. RESULTS: Continuous DopaFuse delivery of LD/CD was associated with reduced variability in plasma levodopa levels compared to oral LD/CD (mean ± SD levodopa Fluctuation Index reduced from 2.15 ± 0.59 on Day1 to 1.50 ± 0.55 on Day 2 (P = 0.0129) and to 1.03 ± 0.53 on Day 3 (P < 0.0001)). This pharmacokinetic improvement translated into significantly reduced OFF time with DopaFuse therapy (reduction of -1.72 ± 0.37 h at Day 15; P = 0.0004) and increased ON time without severe dyskinesias (increase of 1.72 ± 0.37 h at Day 15; P = 0.0004) versus oral LD/CD administration. DopaFuse therapy was not associated with any clinically significant adverse events. CONCLUSIONS: Continuous delivery of LD/CD using the DopaFuse system was associated with significantly less variability in plasma levodopa concentrations and reductions in OFF time compared to treatment with standard oral LD/CD therapy and was well tolerated. © 2024 International Parkinson and Movement Disorder Society.


Assuntos
Antiparkinsonianos , Carbidopa , Levodopa , Doença de Parkinson , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Antiparkinsonianos/farmacocinética , Antiparkinsonianos/administração & dosagem , Carbidopa/farmacocinética , Carbidopa/administração & dosagem , Combinação de Medicamentos , Levodopa/farmacocinética , Levodopa/administração & dosagem , Doença de Parkinson/tratamento farmacológico , Resultado do Tratamento
3.
Periodontol 2000 ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831570

RESUMO

Accurate diagnosis of periodontal and peri-implant diseases relies significantly on radiographic examination, especially for assessing alveolar bone levels, bone defect morphology, and bone quality. This narrative review aimed to comprehensively outline the current state-of-the-art in radiographic diagnosis of alveolar bone diseases, covering both two-dimensional (2D) and three-dimensional (3D) modalities. Additionally, this review explores recent technological advances in periodontal imaging diagnosis, focusing on their potential integration into clinical practice. Clinical probing and intraoral radiography, while crucial, encounter limitations in effectively assessing complex periodontal bone defects. Recognizing these challenges, 3D imaging modalities, such as cone beam computed tomography (CBCT), have been explored for a more comprehensive understanding of periodontal structures. The significance of the radiographic assessment approach is evidenced by its ability to offer an objective and standardized means of evaluating hard tissues, reducing variability associated with manual clinical measurements and contributing to a more precise diagnosis of periodontal health. However, clinicians should be aware of challenges related to CBCT imaging assessment, including beam-hardening artifacts generated by the high-density materials present in the field of view, which might affect image quality. Integration of digital technologies, such as artificial intelligence-based tools in intraoral radiography software, the enhances the diagnostic process. The overarching recommendation is a judicious combination of CBCT and digital intraoral radiography for enhanced periodontal bone assessment. Therefore, it is crucial for clinicians to weigh the benefits against the risks associated with higher radiation exposure on a case-by-case basis, prioritizing patient safety and treatment outcomes.

4.
J Cutan Pathol ; 51(3): 209-213, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38084767

RESUMO

Syphilis can mimic, clinically and microscopically, many other diseases. By microscopy, typically syphilis presents with plasma cell infiltration, admixed with lymphocytes and macrophages, in lichenoid and/or perivascular/perineural distribution pattern. When exuberant, this inflammatory infiltrate can mimic a lymphoproliferative disorder (LPD), notably plasma cell neoplasia or lymphoma. To date, about 12 cases of secondary syphilis, all but one in extraoral location, suggesting initially a LPD, have been published. Here, to our knowledge, we report an unusual case of intraoral primary syphilis initially suggesting LPD, notably lymphoid hyperplasia (pseudolymphoma); however, mucosa-associated lymphoid tissue (MALT) lymphoma and follicular lymphoma could not be disregarded. Polyclonality of plasma cells on immunohistochemistry, in strict clinical correlation, was essential to arrive at the correct diagnosis.


Assuntos
Linfoma de Zona Marginal Tipo Células B , Transtornos Linfoproliferativos , Sífilis , Humanos , Sífilis/diagnóstico , Sífilis/patologia , Transtornos Linfoproliferativos/diagnóstico , Transtornos Linfoproliferativos/patologia , Linfoma de Zona Marginal Tipo Células B/patologia , Linfócitos/patologia , Diagnóstico Diferencial
5.
Support Care Cancer ; 32(3): 150, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38329552

RESUMO

PURPOSE: Many patients experience oral adverse events during head and neck cancer radiotherapy (RT). The methods of management of such events are under debate. One such technique is the intraoral stent (IOS) technique, which removes normal tissue from the irradiation field. This retrospective study examined the factors associated with the occurrence of oral mucositis (OM) and dysgeusia and the efficacy of IOSs in preventing them. METHODS: Twenty-nine patients who underwent RT in the maxilla or nasal cavity between 2016 and 2022 were included. They were investigated for background characteristics, treatment factors (IOS and dose-volume histogram), and oral adverse events (OM and dysgeusia). RESULTS: Significant risk factors for the incidence of grade ≥ 2 (Common Terminology Criteria for Adverse Events v5.0) OM were the non-use of IOSs (p = 0.004) and diabetes (p = 0.025). A significant risk factor for the incidence of grade ≥ 1 dysgeusia was concomitant chemotherapy (p = 0.019). The radiation dose to the tongue was significantly lower in the IOS group than in the non-IOS group. CONCLUSION: Our findings suggest that the use of an IOS during RT reduces the severity of OM by reducing irradiation to the tongue. Therefore, the use of an IOS is recommended during RT performed in the maxilla or nasal cavity.


Assuntos
Neoplasias , Estomatite , Humanos , Maxila , Disgeusia/epidemiologia , Disgeusia/etiologia , Disgeusia/prevenção & controle , Cavidade Nasal , Estudos Retrospectivos , Stents , Estomatite/epidemiologia , Estomatite/etiologia , Estomatite/prevenção & controle
6.
Clin Oral Implants Res ; 35(5): 560-572, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38421115

RESUMO

OBJECTIVES: The purpose of this in vitro study was to compare the trueness and precision of complete arch implant impressions using conventional impression, intraoral scanning with and without splinting, and stereophotogrammetry. MATERIALS AND METHODS: An edentulous model with six implants was used in this study. Four implant impression techniques were compared: the conventional impression (CI), intraoral scanning (IOS) without splinting, intraoral scanning with splinting (MIOS), and stereophotogrammetry (SPG). An industrial blue light scanner was used to generate the baseline scan from the model. The CI was captured with a laboratory scanner. The reference best-fit method was then applied in the computer-aided design (CAD) software to compute the three-dimensional, angular, and linear discrepancies among the four impression techniques. The root mean square (RMS) 3D discrepancies in trueness and precision between the four impression groups were analyzed with a Kruskal-Wallis test. Trueness and precision between single analogs were assessed using generalized estimating equations. RESULTS: Significant differences in the overall trueness (p = .017) and precision (p < .001) were observed across four impression groups. The SPG group exhibited significantly smaller RMS 3D deviations than the CI, IOS, and MIOS groups (p < .05), with no significant difference detected among the latter three groups (p > .05). CONCLUSIONS: Stereophotogrammetry showed superior trueness and precision, meeting misfit thresholds for implant-supported complete arch prostheses. Intraoral scanning, while accurate like conventional impressions, exhibited cross-arch angular and linear deviations. Adding a splint to the scan body did not improve intraoral scanning accuracy.


Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Fotogrametria , Fotogrametria/métodos , Humanos , Técnicas In Vitro , Modelos Dentários , Imageamento Tridimensional/métodos , Arcada Edêntula/diagnóstico por imagem , Implantes Dentários , Boca Edêntula/diagnóstico por imagem , Boca Edêntula/cirurgia , Planejamento de Prótese Dentária
7.
Clin Oral Implants Res ; 35(6): 641-651, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38567801

RESUMO

OBJECTIVE: This in-vitro study assessed the influence of two intraoral scanning (IOS) protocols on the accuracy (trueness and precision) of digital scans performed in edentulous arches. METHODS: Twenty-two abutment-level master casts of edentulous arches with at least four implants were scanned repeatedly five times, each with two different scanning protocols. Protocol A (IOS-A) consisted of scanning the edentulous arch before inserting the implant scan bodies, followed by their insertion and its subsequent digital acquisition. Protocol B (IOS-B) consisted of scanning the edentulous arch with the scan bodies inserted from the outset. A reference scan from each edentulous cast was obtained using a laboratory scanner. Trueness and precision were calculated using the spatial fit analysis, cross-arch distance, and virtual Sheffield test. Statistical analysis was performed using generalized estimating equations (GEEs). Statistical significance was set at α = .05. RESULTS: In the spatial fit test, the precision of average 3D distances was 45 µm (±23 µm) with protocol IOS-A and 25 µm (±10 µm) for IOS-B (p < .001), and the trueness of average 3D distances was 44 µm (±24 µm) with protocol IOS-A and 24 µm (±7 µm) for IOS-B (p < .001). Cross-arch distance precision was 59 µm (±53 µm) for IOS-A and 41 µm (±43 µm) for IOS-B (p = .0035), and trueness was 64 µm (±47 µm) for IOS-A and 50 µm (±40 µm) for IOS-B (p = .0021). Virtual Sheffield precision was 286 µm (±198 µm) for IOS-A and 146 µm (±92 µm) for IOS-B (p < .001), and trueness was 228 µm (±171 µm) for IOS-A and 139 µm (±92 µm) for IOS-B (p < .001). CONCLUSIONS: The IOS-B protocol demonstrated significantly superior accuracy. Placement of scan bodies before scanning the edentulous arch is recommended to improve the accuracy of complete-arch intraoral scanning.


Assuntos
Imageamento Tridimensional , Humanos , Técnicas In Vitro , Imageamento Tridimensional/métodos , Implantes Dentários , Desenho Assistido por Computador , Arcada Edêntula/diagnóstico por imagem , Modelos Dentários , Arco Dental/diagnóstico por imagem , Arco Dental/anatomia & histologia
8.
Clin Oral Implants Res ; 35(3): 305-320, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38124678

RESUMO

OBJECTIVES: Intermittent administration of parathyroid hormone (PTH) increases systemic bone mass. However, the effect of PTH on osseous and soft tissue healing around implants in osteoporosis patients remains unclear. This study aimed to investigate the effects of PTH on tissue healing around implants in ovariectomized rats and to compare systemic and intraoral administration routes. MATERIAL AND METHODS: Implants were placed at the healed sites of ovariectomized rats 3 weeks after maxillary first molar extraction. Rats were randomly divided into two groups that received either daily systemic subcutaneous or local intraoral PTH administration. Maxillae were dissected to examine bone architectures with micro-computed tomography images. Histomorphometric and immunohistochemical analyses were performed to evaluate osseous and soft tissue healing around the implants. RESULTS: Regardless of the administration route, PTH significantly increased bone area and the numbers of osteoblasts, osteoclasts, and osteocytes in the first and second inside and outside areas of implant threads, in addition to decreasing the number of sclerostin+ osteocytes. However, the intraoral PTH administration route was superior to the systemic route by significantly improving bone quality and promoting collagen production in the connective tissue around implants. CONCLUSIONS: Parathyroid hormone administration promoted both osseous and soft tissue healing around implants, irrespective of administration route. Interestingly, intraoral administration improved the evaluated parameters more than systemic administration. Thus, the intraoral route could become a useful treatment strategy for implant treatment in osteoporosis patients.


Assuntos
Implantes Dentários , Osteoporose , Humanos , Ratos , Animais , Hormônio Paratireóideo/farmacologia , Maxila/diagnóstico por imagem , Maxila/cirurgia , Microtomografia por Raio-X
9.
Oral Dis ; 2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38852162

RESUMO

OBJECTIVE: This study focused on the metabolic characteristics of tongue coating in patients with intra-oral halitosis (IOH) to investigate potential diagnostic biomarkers for IOH. METHODS: Oral healthy participants were enrolled in this study. Halitosis was evaluated with an organoleptic assessment, a Halimeter®, and an OralChroma™. Tongue coating samples were collected from 18 halitosis patients and 18 healthy controls. Liquid chromatography-mass spectrometry was conducted to reveal the IOH-related metabolic variations in tongue coating. RESULTS: A total of 2214 metabolites were obtained. Most metabolites were shared between the two groups. A total of 274 upregulated metabolites, such as paramethasone acetate and indole-3-acetic acid, and 43 downregulated metabolites, including deoxyadenosine and valyl-arginine, were detected in the halitosis group. Functional analysis indicated that several metabolic pathways, including arginine biosynthesis, arginine and proline metabolism, histidine metabolism, and lysine degradation were significantly enriched in the IOH group. The least absolute shrinkage and selection operator logistic regression analysis revealed that paramethasone acetate, {1-[2-(4-carbamimidoyl-benzoylamino)-propionyl]-piperidin-4-yloxy}-acetic acid, indole-3-acetic acid, and valyl-arginine were remarkably associated with IOH. CONCLUSIONS: This study revealed the metabolites present in tongue coating and identified effective biomarkers, providing essential insights into the prediction, pathogenesis, and diagnosis of IOH.

10.
Lasers Surg Med ; 56(6): 534-540, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38741345

RESUMO

PURPOSE: Intraoral hair growth is a debilitating side effect of flap or graft-based oropharyngeal reconstruction. There is no standardized treatment, but groups have successfully eradicated unwanted hair growth with intraoral laser hair removal. This scoping review assesses the utility of laser therapy in managing this condition. METHODS: This scoping review followed PRISMA-ScR guidelines. Ovid Medline, Embase (Ovid) and Scopus were queried using index terms and keywords. Resulting articles were reviewed for inclusion by two independent reviewers against inclusion criteria and relevant data were extracted. RESULTS: The literature search yielded 297 articles, 22 of which met inclusion criteria. In total, 77 patients were treated: 38 patients with an Alexandrite laser, 19 with an Nd:YAG laser, 18 with a diode laser, and two with a CO2 laser. Complete response defined as 80% or more reduction in hair count was achieved in 70 patients (90%) and six patients (8%) achieved a partial response (10%-79% reduction in hair count). One patient (1%) with gray hair saw less than a 10% reduction in hair count. On average, 3.84 treatment sessions were needed, spaced 5.4 weeks apart. Treatments were well tolerated without major side effects. CONCLUSIONS: This is the first scoping review assessing the utility of intraoral laser hair therapy and suggests it may be a safe and effective treatment. However, surgeons should advise preoperative hair removal when clinically feasible to mitigate this side effect as much as possible.


Assuntos
Remoção de Cabelo , Humanos , Remoção de Cabelo/métodos , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Resultado do Tratamento
11.
Orthod Craniofac Res ; 27(1): 44-54, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37300347

RESUMO

OBJECTIVE: To evaluate any distortion produced by multibracket fixed orthodontic appliances on digital models obtained from intraoral scans (IOS), considering the presence of both brackets only and brackets/archwire combination. SETTING/SAMPLE: The IOS data of the arches of 20 patients (12 females and 8 males; mean age = 15.55 ± 2.84 years) were acquired using the CS3600 intraoral scanner (Carestream Dental, Atlanta, USA), without any appliances (model A), with vestibular brackets alone (model B) and then with brackets and orthodontic archwire fitted (model C). MATERIALS AND METHODS: Data were acquired between the months of January and October 2021 at the moment of indirect bonding phase. On each model, five intra-arch linear measurements were obtained (inter-canine, inter-premolar 1 and 2, inter-molar and arch depth), and after digital matching between model A and B (match 1) and A and C (match 2), the linear discrepancies were evaluated at 20 points (10 occlusal and 10 gingivolingual) previous identified on the reference model A. All measurements were performed using Geomagic Control X software (3D Systems, Morrisville, USA), and any dimensional variations and distortions were evaluated by the linear regression analysis and two-sample t-test (P ≤ .05). RESULTS: The results show an almost perfect correlation between both models B and C and the reference model A, both as regards the intra-arch linear measurements and the linear discrepancies found at the 20 identified points. CONCLUSIONS: Multibracket fixed orthodontic appliances do not produce any relevant distortions in digital models obtained via intraoral scanning. Therefore, the removal of archwire is not mandatory before IOS.


Assuntos
Braquetes Ortodônticos , Fios Ortodônticos , Masculino , Feminino , Humanos , Criança , Adolescente , Estudos Prospectivos , Aparelhos Ortodônticos , Software , Imageamento Tridimensional/métodos
12.
Orthod Craniofac Res ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38859724

RESUMO

BACKGROUND: To compare and investigate the effects of intraoral ageing on the thickness of one group of directly printed and two groups of thermoformed aligners on the labial surface of maxillary central incisors. MATERIALS AND METHODS: Six groups (12 samples per group) were included in this prospective in vivo experiment. Groups DP-Clin, INV-Clin and CA-Clin consisted of directly printed (Tera Harz TC-85 DAC resin), thermoformed (Invisalign, PU based polymer) and in house thermoformed (CA-Pro, PET-G based polymer) aligners, retrieved after 1 week of intraoral service. Groups DP-Ctr, INV-Ctr and CA-Ctr included unused aligners samples. Thickness measurements were conducted using confocal laser scanning microscopy (CLSM). Data that underwent log-10 transformation was analysed by multiple linear regression analysis (p < .05). RESULTS: Statistically significant differences were found between the materials in both Clin and Ctr categories (p < .001). Group DP had the highest thickness among the groups and the least thickness was observed in the CA group (p < .001). However, intraoral ageing did not significantly affect the aligner thickness of any groups. CONCLUSIONS: Both thermoforming and direct printing of clear aligners led to thickness deviations in terms of increase for printed aligners and decrease for thermoformed aligners. Intraoral ageing did not affect the aligner thickness in any of the groups.

13.
J Neuroeng Rehabil ; 21(1): 2, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166962

RESUMO

BACKGROUND: Analysis of tongue movement would benefit from a reference showcasing healthy tongue capability. We aimed to develop a reference of tongue capability and evaluated the role of visual feedback on the expression of movement. METHODS: Using a wireless tracking intraoral wearable device, we composed probability distributions of the tongue tip as subjects were asked to explore the entire sensing surface area. Half of the 32 subjects received live visual feedback of the location of the center of the tongue tip contact. RESULTS: We observed that the visual feedback group was 51.0% more consistent with each other in the position domain, explored 21.5% more sensing surface area, and was 50.7% more uniformly distributed. We found less consistent results when we evaluated velocity and acceleration. CONCLUSION: Visual feedback best established a healthy capability reference which can be used for designing new interfaces, quantifying tongue ability, developing new diagnostic and rehabilitation techniques, and studying underlying mechanisms of tongue motor control.


Assuntos
Retroalimentação Sensorial , Língua , Humanos , Movimento , Retroalimentação
14.
Clin Oral Investig ; 28(6): 350, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822893

RESUMO

OBJECTIVES: The study continues our longitudinal observation of wear aiming to further monitoring of progression and lesion morphology and to identify relationships with assumed aetiological factors. MATERIALS AND METHODS: Molars (FDI #36 or #46) of 74 participants (23.8 ± 2.2 years) were scanned (Trios 3, 3Shape) at the third follow-up (T3; observation period 1,111 ± 10 days). Data sets from T3, T2 (24-month follow-up) and T1 (12-month follow-up) were superimposed with baseline in a 3D analysis software (GOM Inspect). Wear was quantified as maximum vertical tissue loss (µm; median, 95% CI) in various occlusal areas (4/5 cusps and 2 ridges). Morphologies were classified into cupping (C), facet (F), and combined cupping-facet (CF). Aetiological factors were assessed with questionnaires. RESULTS: Wear increased at T3 significantly at low rates in all areas of the occlusal surface (median between 7.0 (4.0;10.5) and 9.5 (6.0;15.0) µm). There was a clear trend for higher loss values in males, but no association with other factors such as nutrition. C and CF showed significantly higher loss values than F. Areas without initial wear developed F first, which either persisted or developed into C and CF. CONCLUSIONS: Wear continued at low rates with C/CF morphology and sex as significant factors. Cupped lesions seem to develop from facets and thus may not be a valid diagnostic criterion for erosive tooth wear. CLINICAL RELEVANCE: Wear is a cumulative process that apparently follows complex mechanisms that cannot be conceptualized in simplified terms; C and CF may be indicators for higher progression rates.


Assuntos
Desgaste dos Dentes , Humanos , Masculino , Feminino , Estudos Longitudinais , Adulto Jovem , Imageamento Tridimensional/métodos , Dente Molar/patologia , Adulto , Inquéritos e Questionários
15.
Odontology ; 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38197987

RESUMO

Early-life stress affects brain development, eventually resulting in adverse behavioral and physical health consequences in adulthood. The present study assessed the hypothesis that short-term early-life stress during infancy before weaning, a period for the maturation of mastication and sleep, poses long-lasting adverse effects on masticatory function and intraoral sensations later in life.Rat pups were exposed to either maternal separation (MS) or intermittent hypoxia (IH-Infancy) for 6 h/day in the light/sleep phase from postnatal day (P)17 to P20 to generate "neglect" and "pediatric obstructive sleep apnea" models, respectively. The remaining rats were exposed to IH during P45-P48 (IH-Adult). Masticatory ability was evaluated based on the rats' ability to chew pellets and bite pasta throughout the growth period (P21-P70). Intraoral chemical and mechanical sensitivities were assessed using two-bottle preference drinking tests, and hind paw pain thresholds were measured in adulthood (after P60).No differences were found in body weight, grip force, and hind paw sensitivity in MS, IH-Infancy, and IH-Adult rats compared with naïve rats. Masticatory ability was lower in MS and IH-Infancy rats from P28 to P70 than in naïve rats. MS and IH-Infancy rats exhibited intraoral hypersensitivity to capsaicin and mechanical stimulations in adulthood. The IH-Adult rats did not display inferior masticatory ability or intraoral hypersensitivity.In conclusion, short-term early-life stress during the suckling-mastication transition period potentially causes a persistent decrease in masticatory ability and intraoral hypersensitivity in adulthood. The period is a "critical window" for the maturation of oral motor and sensory functions.

16.
Odontology ; 112(2): 640-646, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37880466

RESUMO

The treatment of mandibular deformities with an anterior open bite is challenging. In this study, skeletal stability after mandibular osteotomies was evaluated to determine the best treatment for mandibular prognathism with an anterior open bite in three procedures: intraoral vertical ramus osteotomy (IVRO), conventional sagittal split ramus osteotomy (conv-SSRO), and SSRO without bone fixation (nonfix-SSRO). Patients who underwent mandibular osteotomy to correct skeletal mandibular protrusion were included. Changes in skeletal and soft tissues were assessed using lateral cephalograms taken before (T1), 3 ± 2 days (T2), and 12 ± 3 months (T3) after surgery. Thirty-nine patients were included: nine in the IVRO group and 11 and 19 in the conv- and nonfix-SSRO groups, respectively. The mandibular plane angles (MPAs) of the T2-T1 were - 2.7 ± 2.0 (p = 0.0040), - 3.7 ± 1.7 (p < 0.0001), and - 2.3 ± 0.7 (p < 0.0001) in the IVRO, conv-SSRO, and nonfix-SSRO groups, respectively. The skeletal relapse of the MPAs was not related to the MPA at T2-T1, and it was approximately 1.3° in the conv-SSRO group. The skeletal relapse of the MAPs was significantly correlated with the MPA of T2-T1 in the IVRO (p = 0.0402) and non-fix-SSRO (p = 0.0173) groups. When the relapse of the MPAs was less than 1.3°, the MPA of T2-T1 was calculated as 2.5° in the nonfix-SSRO group. When the MPA of T2-T1 is less than 2.5°, non-fix SSRO may produce a reliable outcome, and when it is more than 2.5°, conv-SSRO may produce better outcomes.


Assuntos
Mordida Aberta , Prognatismo , Humanos , Prognatismo/cirurgia , Rotação , Mandíbula/cirurgia , Osteotomia Sagital do Ramo Mandibular/métodos , Cefalometria/métodos , Recidiva
17.
J Oral Rehabil ; 51(8): 1349-1356, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38641860

RESUMO

BACKGROUND: There is growing interest in the development of objective methods for assessing lip-closing function in children. OBJECTIVE: To obtain normative data for healthy children in the developmental stages of lip closure function, we quantitatively evaluated oral movements associated with lip closure in children and adults using a composite sensor (CS). METHODS: Twenty-five normal children (11 boys, 14 girls) aged 8.8 ± 1.6 years and 25 young adults (13 men, 12 women) aged 27.4 ± 3.9 years were asked to perform test movements, maximal lip closure and swallowing of 3 mL of water. Lip-closing pressure (LP), intraoral baro-pressure (IP) and electromyographic (EMG) activity of the upper orbicularis oris muscle were simultaneously recorded using the CS. RESULTS: EMG activity of the upper orbicularis oris muscle during closure was significantly greater in adults than in children. There were significant positive correlations between integral values of LP and EMG for closure in adults (r = .527, p = .008) but not in children, and significant positive correlations between integral values of LP and IP for swallowing in children (r = .508, p = .010) but not in adults. CONCLUSIONS: The CS may provide an effective tool for evaluating lip function in children acquiring oral function. For the combination of maxillary orbicularis oculus contraction and formation of intraoral negative pressure, EMG activity of the upper orbicularis oris muscle involvement in LP and IP involvement in LP may differ between children and adults.


Assuntos
Deglutição , Eletromiografia , Músculos Faciais , Lábio , Humanos , Deglutição/fisiologia , Lábio/fisiologia , Feminino , Masculino , Criança , Adulto , Músculos Faciais/fisiologia , Adulto Jovem , Valores de Referência , Pressão
18.
J Esthet Restor Dent ; 36(2): 278-283, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37681471

RESUMO

OBJECTIVE: The present manuscript describes a technique to virtually switch an implant scan body eliminating the need of obtaining a new intraoral implant digital scan. CLINICAL CONSIDERATIONS: Implant scan bodies assist on transferring the 3-dimensional position of the implants into the virtual definitive implant cast. However, if a different implant part is desired during the designing procedures of the implant restoration such as selecting a different implant abutment of varying height, angulation, or manufacturer, a new intraoral implant digital scan with the specific implant scan body is required. CONCLUSIONS: This novel protocol aims to reduce possible complications that require capturing a new intraoral implant digital scan, facilitate prostheses design modifications after the obtention of the definitive intraoral implant digital scan, and to ease the manufacturing procedures. CLINICAL SIGNIFICANCE: The novel technique may provide a solution for virtually switch implant scan bodies for fabricating implant-supported single crowns or short-span prostheses. Additional studies are needed before its clinical implementation.


Assuntos
Desenho Assistido por Computador , Implantes Dentários , Coroas , Técnica de Moldagem Odontológica , Imageamento Tridimensional
19.
J Esthet Restor Dent ; 36(8): 1179-1198, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38534043

RESUMO

AIM: The aim of this study was to compare the accuracy of full-arch conventional implant impressions using two different materials (A-silicone and polyether) to full-arch digital implant impressions produced from two intraoral scanning devices. MATERIALS AND METHODS: A master model was fabricated representing an edentulous mandible with four implants with internal connection placed at the sites of canines and first molars. The anterior implants were parallel to the residual ridge, while the two posterior implants had an angulation of 15° to the distal and 15° to the lingual respectively. The conventional technique was performed with open-tray of non-splinted impression copings. Two different impression materials were used, A-silicone and polyether at monophase medium body consistencies. The digital impressions were obtained with the use of two different intraoral scanners, after the connection of scan bodies. A total of 10 impressions were produced for each of the four experimental groups. The conventional models as well as the master model were digitized using a high-resolution laboratory scanner. The STL files of the models and of the intraoral impressions were imported in a powerful superimposition software, for the conduction of measurements in pairs of files. The software calculated the 3D deviations, as well as the linear and angular displacements among scan bodies at the digital files. For "trueness" measurements every STL file of each experimental group was superimposed to the digital master model, while for "precision" measurements all STL files of each experimental group were superimposed to each other. RESULTS AND CONCLUSIONS: The accuracy of full arch mandibular implant impressions was influenced both by the impression technique used (conventional vs. digital) and the impression material used (A-silicone vs. polyether) or the intraoral scanner used (Trios vs. Heron). In terms of "trueness," A-silicone showed the highest impression accuracy with the lowest deviation values, followed by polyether and Trios, but the differences between the three groups were in the majority not statistically significant. Heron showed statistically lower accuracy results in all measurements compared to the other groups. In terms of "precision", conventional impressions with the use of A-Silicone or polyether were statistically significantly superior to digital impressions with either scanner. A-Silicone and polyether showed no statistically significant difference between them.


Assuntos
Técnica de Moldagem Odontológica , Materiais para Moldagem Odontológica , Humanos , Técnicas In Vitro , Elastômeros , Desenho Assistido por Computador , Modelos Dentários
20.
J Esthet Restor Dent ; 36(6): 845-857, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38263949

RESUMO

OBJECTIVE: This study aimed to evaluate the accuracy of an intraoral scanner with near-infrared imaging (NIRI) feature in the diagnosis of interproximal caries and to compare it with the visual-tactile method (VTM), bitewing radiography (BWR), and panoramic radiography (PR). MATERIALS AND METHODS: Six hundred thirty-nine interproximal surfaces (mesial-distal) of posterior teeth from 22 volunteers were examined. Results were scored by VTM, BWR, PR, and NIRI. Lesions were scored as 0 for no-caries, 1 for early-enamel lesion (EEL), and 2 for lesions involving dentino-enamel junction (DEJ). McNemar, Kappa, and Fleis Kappa tests were used to evaluate the agreement levels. Pearson's Chi-square test was used to determine the matching rates after validation. RESULTS: A good level of agreement was observed between examination methods (Ƙ = 0.613; p < 0.001). In pairwise comparisons, a moderate agreement was seen between all the methods for lesions with DEJ involvement, while a statistically good agreement was observed between BWR and NIRI (Ƙ = 0.675; p < 0.001). As a result of validation, the accuracy of NIRI for molars was considered 85.2% and 75.7% for premolars in EELs, 85.2% for molars, and 70% for premolars regarding the lesions involving DEJ. CONCLUSIONS: Intraoral scanners with the NIRI feature may be used for diagnosing interproximal caries, especially for permanent molars. CLINICAL SIGNIFICANCE: Early detection of proximal caries is one of the most essential topics forming the basis of preventive dentistry. This study investigates a caries diagnostic tool integrated into intraoral scanners to diagnose interproximal caries. A caries diagnostic tool integrated into an intraoral scanner may prevent the harmful effects of ionizing radiation in early caries diagnosis and may improve the patient's oral health status.


Assuntos
Cárie Dentária , Humanos , Cárie Dentária/diagnóstico por imagem , Adulto , Feminino , Masculino , Radiografia Panorâmica
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa