RESUMO
BACKGROUND: Thermal ablation has recently become a key therapy for the treatment of colorectal liver metastasis (CLM). However, the role of ablation in combination with resection has not yet been firmly established. We hypothesize that in patients with CLM, those who undergo liver resection with ablation (RA) have similar outcomes compared with those who undergo liver resection only. METHODS: We reviewed a multicenter international database of 906 surgical procedures for CLM from 5 high volume hepatobiliary surgical units. Patients undergoing RA (n = 63) were matched based on the number of lesions and tumor size using a 1:1 balanced propensity score analysis with those having resection only (n = 63). Our primary outcomes were overall survival (OS) and disease-free survival (DFS). RESULTS: The mean age of our cohort was 58 ± 11 years, with 43% females. With a median follow-up of 70.8 months, patients in the resection and RA group had a median OS of 45.1 and 54.8 months (p = 0.71), respectively. The median DFS was 22.7 and 14.2 months (p = 0.045), respectively. Using a multivariate Cox proportional hazards regression model, the treatment approach was not associated with OS (p = 0.94) or DFS (p = 0.059). A higher number of lesions is independently associated with worse DFS (hazard ratio: 1.12, p < 0.01). When there was disease recurrence, the region of recurrence was similar between the RA versus resection only groups (p = 0.27), but there was a shorter time to recurrence in the RA group (p = 0.002). CONCLUSION: For CLM, the treatment approach was not significantly associated with OS or DFS, while tumor biology likely played an important role. Prospective research on the quality and effectiveness of thermal ablation combined with hepatic resection is warranted.
Assuntos
Neoplasias Colorretais , Hepatectomia , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/mortalidade , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/mortalidade , Feminino , Masculino , Hepatectomia/mortalidade , Hepatectomia/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Ablação por Cateter/mortalidade , Ablação por Cateter/métodos , Taxa de Sobrevida , Idoso , Seguimentos , Terapia CombinadaRESUMO
BACKGROUND: Patients with colorectal liver metastases (CRLM) who undergo thermal ablation are at risk of developing new CRLM after ablation. Identification of these patients might enable individualized treatment. PURPOSE: To investigate whether an existing machine-learning model with radiomics features based on pre-ablation computed tomography (CT) images of patients with colorectal cancer can predict development of new CRLM. MATERIAL AND METHODS: In total, 94 patients with CRLM who were treated with thermal ablation were analyzed. Radiomics features were extracted from the healthy liver parenchyma of CT images in the portal venous phase, before thermal ablation. First, a previously developed radiomics model (Original model) was applied to the entire cohort to predict new CRLM after 6 and 24 months of follow-up. Next, new machine-learning models were developed (Radiomics, Clinical, and Combined), based on radiomics features, clinical features, or a combination of both. RESULTS: The external validation of the Original model reached an area under the curve (AUC) of 0.57 (95% confidence interval [CI]=0.56-0.58) and 0.52 (95% CI=0.51-0.53) for 6 and 24 months of follow-up. The new predictive radiomics models yielded a higher performance at 6 months compared to 24 months. For the prediction of CRLM at 6 months, the Combined model had slightly better performance (AUC=0.60; 95% CI=0.59-0.61) compared to the Radiomics and Clinical models (AUC=0.55-0.57), while all three models had a low performance for the prediction at 24 months (AUC=0.52-0.53). CONCLUSION: Both the Original and newly developed radiomics models were unable to predict new CLRM based on healthy liver parenchyma in patients who will undergo ablation for CRLM.
Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Neoplasias Colorretais/diagnóstico por imagemRESUMO
Interventional oncology plays a major role within modern oncological patient management. Image-guided thermal ablation has been recognized as a successful local therapeutic option in patients with primary and secondary malignant liver diseases, as also recalled by the recent European Society of Medical Oncology (ESMO) guidelines on colorectal metastases. As image-guided treatments may be as effective as surgery in selected patients with liver lesions, the clinical oncologist should be familiar with the indications, risks, and technical aspects of liver ablation in order to provide their patients with the best outcomes. This article provides a broad overview of the most commonly used ablation techniques and highlights the most relevant technical aspects such as the ideal setting in the operating theatre; which image-guided methods are available, including the growing application of fusion imaging; or contrast-enhanced ultrasound for guiding/monitoring the procedure. A further aim is to expand the knowledge among medical oncologists about liver ablation procedures and to provide insights into the future perspectives of percutaneous minimally invasive procedures in the liver.
Assuntos
Criocirurgia/métodos , Eletroporação/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Hipertermia Induzida/métodos , Neoplasias Hepáticas/cirurgia , Oncologistas , Ablação por Radiofrequência/métodos , Cirurgia Assistida por Computador/métodos , Terapia Combinada/métodos , Humanos , Oncologia Cirúrgica/métodos , Resultado do TratamentoRESUMO
BACKGROUND: High-Frequency Irreversible Electroporation (H-FIRE) is a novel technology for non-thermal ablation. Different from Irreversible electroporation (IRE), H-FIRE delivers bipolar electrical pulses without muscle contraction and does not cause electrolysis. Currently, little is known regarding the cardiac safety during the administration of H-FIRE on liver. The aim of this study was to evaluate the changes of electrocardiogram (ECG) and biomarkers of cardiac damage during asymmetrical waveform of H-FIRE therapy in vivo. METHODS: The swines (n = 7) in IRE group, which used 100 pulses (2200 V, 100-100 µs configuration), were administrated with muscle relaxant under anesthesia. In the absence of muscle relaxant, 7 swines in H-FIRE group were performed with 2400 pulses (3000 V, 5-3-3-5 µs configuration). Midazolam (0.5 mg/kg) and xylazine hydrochloride (20 mg/kg) were given to induce sedation, followed by Isoflurane (2.5%, 100% oxygen, 3 L/min) to maintain sedation in all the swines. Limb lead ECG recordings were analyzed by two electrophysiologists to judge the arrhythmia. Cardiac and liver tissue was examined by pathology technique. RESULTS: The ablation zones were larger in H-FIRE than IRE. Both IRE and H-FIRE did not affect the autonomous cardiac rhythm. Even when the electrical signal of IRE and H-FIRE fell on ventricular vulnerable period. Moreover, cTnI in IRE group showed an increase in 4 h after ablation, and decreased to baseline 72 h after ablation. However, cTnI showed no significant change during the administration of H-FIRE. CONCLUSIONS: The study suggests an asymmetrical waveform for H-FIRE is a promising measure for liver ablation. The results were based on normal liver and the swines without potential cardiac diseases. With the limitations of these facts, asymmetrical waveform for H-FIRE of liver tissue seems relatively safe without major cardiac complications. The safety of asymmetrical waveform for H-FIRE needs to evaluate in future.
Assuntos
Técnicas de Ablação/efeitos adversos , Arritmias Cardíacas/etiologia , Eletroporação , Traumatismos Cardíacos/etiologia , Fígado/cirurgia , Potenciais de Ação , Animais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Feminino , Traumatismos Cardíacos/patologia , Frequência Cardíaca , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Miocárdio/patologia , Suínos , Porco Miniatura , Fatores de TempoRESUMO
PURPOSE: Microwave ablation (MWA) provides an effective treatment of lung and liver tumors but suffers from a lack of reproducibility of ablation size among currently available technologies. In-vitro evaluations are far removed from clinical practices because of uninfused tissue. This study is in-vivo preclinical testing of a new MWA system on swine lungs and liver. MATERIALS AND METHODS: All ablations were performed under CT guidance and multiple algorithms were tested with a power of 50, 75, and 100 W for durations of 3, 5, 8, 10, and 15 min. A 3 D-evaluation of the ablation zone was carried out using enhanced-CT. The sphericity index, coefficients of variation, and energy efficiency (which corresponds to the volume yield according to the power supplied) were calculated. RESULTS: Fifty liver and 48 lung ablations were performed in 17 swine. The sphericity index varies from 0.50 to 0.80 for liver ablations and from 0.40 to 0.69 for lung ablations. The coefficient of variation was below 15% for 4/5 and 4/8 protocols for lung and liver ablations, respectively. The energy efficiency seems to decrease with the duration of the ablation from 0.60 × 10-3 cm3/J (75 W, 3 min) to 0.26 × 10-3 cm3/J (100 W, 15 min) in the liver and from 0.57 × 10-3 cm3/J (50 W, 10 min) to 0.42 × 10-3 cm3/J (100 W, 12 min) in the lungs. CONCLUSION: A shorter treatment time provides the best energy efficiency, and the best reproducibility is obtained for a 10 min treatment duration. The system tested provides an interesting reproducibility in both lung and liver measurements. Our results may help interventional radiologists in the optimal selection of treatment parameters.
Assuntos
Técnicas de Ablação , Ablação por Cateter , Animais , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Micro-Ondas , Reprodutibilidade dos Testes , Suínos , Tomografia Computadorizada por Raios XRESUMO
BACKGROUND: Microwaves (MWs) deliver relatively high temperatures into biological tissue and cover a large ablation zone. This study aims to evaluate the efficacy and effectiveness of water-cooled double-needle MW ablation arrays in assisting the hepatic transection of an in vivo pig model. METHODS: Our research program comprised computer modeling, tissue-mimicking phantom experiments, and in vivo pig liver experiments. Computer modeling was based on the finite element method (FEM) to evaluate ablation temperature distributions. In tissue-mimicking phantom and in vivo pig liver ablation experiments, the performances of the water-cooled MW ablation array and conventional clamp crushing liver resection were compared. RESULTS: FEM showed that the maximum lateral ablation diameter at 100 W output and a duration of 60 s was 3 cm (assessed at 50 °C isotherm). In the phantom, the maximum transverse ablation diameter of the double-needle MW ablation increased rapidly to 3 cm in 60 s at 50 W. The blood loss and blood loss per transection area in Group A were significantly lower than those in Group B (18 (7-26) ml vs. 34 (19-57) ml, and 2.4 (2-3.1) ml/cm2 vs. 6.9 (3.2-8.3) ml/cm2, respectively) (p < 0.05). The transection speed in Group A (2.6(1.9-3.8) cm2/min) was significantly faster than that in Group B (1.7(1.1-2.2) cm2/min) (p < 0.05). CONCLUSION: In this experimental model, the new water-cooled MW array-assisted liver resection (LR) has the potential advantage of less blood loss and rapid removal than the conventional LR.
Assuntos
Ablação por Cateter , Micro-Ondas , Animais , Hepatectomia , Fígado/diagnóstico por imagem , Fígado/cirurgia , Suínos , ÁguaRESUMO
BACKGROUND: High-frequency jet ventilation is necessary to reduce organ movements during stereotactic liver ablation. However, post-operative hypertensive episodes especially following irreversible electroporation ablation compared with microwave ablation initiated this study. The hypothesis was that hypertensive episodes could be related to ventilation or ablation method. METHODS: The aim of this retrospective study was to assess the proportion of patients with hypertensive events during recovery following liver ablation under general anaesthesia and to analyse the relation to ventilation and ablation technique. A medical chart review of 134 patients undergoing either high-frequency jet ventilation and microwave ablation (n = 45), high-frequency jet ventilation and irreversible electroporation (n = 44), or conventional ventilation and microwave ablation (n = 45) was performed. The proportion of patients with at least one episode of systolic arterial pressure 140-160, 160-180 or >180 mmHg during early recovery and the impact of ventilation method was studied. RESULTS: Out of 134 patients, 100, 75 and 34 patients had at least one episode of mild, moderate and severe hypertension. Microwave ablation, as well as high frequency jet ventilation, was associated with an increased odds ratio for post-operative hypertension. The proportion of patients with at least one severe hypertensive event was 18/45, 9/44 and 7/45, respectively. CONCLUSION: Both ventilation and ablation technique had an impact on post-operative hypertensive episodes. The microwave ablation/high-frequency jet ventilation combination increased the risk as compared with irreversible electroporation/high-frequency jet ventilation and microwave ablation/conventional ventilation.
Assuntos
Ventilação em Jatos de Alta Frequência , Hipertensão , Neoplasias Hepáticas , Humanos , Hipertensão/epidemiologia , Neoplasias Hepáticas/cirurgia , Estudos RetrospectivosRESUMO
BACKGROUND: Videolaparoscopic (VL) microwave ablation (MWA) is not included in most of the international guidelines as a therapeutic option for hepatocellular carcinoma (HCC). Aim of this study was to assess the safety of VL MWA in patients with HCC for whom resection or percutaneous ablation is unsuitable. METHODS: A retrospective analysis was performed on a prospective database of patients with HCC treated with VL MWA at our institution from 2009 to 2016. Patient demographics, operational characteristics, and complications were recorded. Statistical analysis was performed to identify safety profile, overall survival and recurrence rate. RESULTS: A total of 815 VL MWA were performed in 674 patients with a mean age of 64 years. Patients had a mean Model for End-stage Liver Disease score of 10 (±3); 32.8% were Child B, 44.1% Barcelona Clinic Liver Cancer B-C. Perioperative mortality was 0.4%. Overall morbidity was 30.8%, with Dindo-Clavien complications ≥3 in 2%. The median length of stay was 2 days. In 43.1% VL MWA was the first-line therapy. Overall 1-, 3-, and 5-year survival rates were 81.9%, 54.9%, and 35.9%. CONCLUSIONS: The present is the largest series of VL ablation and the bigger number of patients with HCC treated with MW reported nowadays. It confirms the safety of a minimally invasive procedure for patients with HCC when resection or percutaneous ablation is not feasible.
Assuntos
Carcinoma Hepatocelular/terapia , Ablação por Cateter/mortalidade , Hospitais com Alto Volume de Atendimentos/estatística & dados numéricos , Laparoscopia/mortalidade , Neoplasias Hepáticas/terapia , Micro-Ondas/uso terapêutico , Cirurgia Vídeoassistida/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Europa (Continente) , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/patologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Taxa de SobrevidaRESUMO
Microwave ablation (MWA) has been proposed to suffer less from the heat sink effect compared to radiofrequency ablation but has been reported to cause extension of the ablation zone along intrahepatic vessels in clinical practice. To study this effect in detail, eight fresh porcine livers were perfused in an ex vivo organ perfusion system. Livers were perfused with oxygenated, O-positive human blood at 37 °C. Perfusion was discontinued immediately before ablation in the non-perfused group (n = 4) whilst in the perfused group (n = 4) perfusion was maintained during MWA (140 W X 2 min). Large intrahepatic vessels (> 6 mm) were avoided using ultrasound. MWA zones were bisected within 30 min of perfusion termination and sections were fixed in formalin and stained with H&E and NADH to assess cell viability. Magnetic resonance imaging (MRI) was performed on two livers (one perfused, one non-perfused) to provide imaging correlation before sectioning. Twenty-one out of a total of 30 MW ablation zones (70%) showed extension of the ablation zone along a vessel. There was no statistically significant difference (p = 1) in the incidence of ablation zone extension between perfused (9/13, 69%) and non-perfused organs (12/17, 71%). MRI also demonstrated ablation zone extension along blood vessels correlating with macroscopy in two livers. NADH staining also confirmed extension of the ablation zone. Liver MWA appears to be commonly associated with propagated thermal injury along adjacent vessels and occurs independent of active blood flow. In order to avoid possible complications through non-target tissue injury, this effect requires further investigation.
Assuntos
Ablação por Cateter/métodos , Fígado/cirurgia , Micro-Ondas/uso terapêutico , Animais , Modelos Animais de Doenças , Fígado/patologia , SuínosRESUMO
Focused ultrasound (FUS/HIFU) relies on ablation of pathological tissues by delivering a sufficiently high level of acoustic energy in situ of the human body. Magnetic Resonance guided FUS (MRgFUS/HIFU) and Ultrasound guided (USgFUS/HIFU) are image guided techniques combined with therapeutic FUS for monitoring purposes. The principles and technologies of FUS/HiFU are described in this paper including the basics of MR guidance techniques and MR temperature mapping. Clinical applications of FUS/HIFU gained CE and FDA approvals for the treatment of various benign and few malignant lesions in the last two decades. Current technical limitations of ultrasound guided and MRI guided Focused Ultrasound, as well as adverse effects for the application of this technique are outlined including challenges of ablating moving organs (liver and kidney). An outlook to possible applications is provided; exampling clinical trials discussing future options.
Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Rim/cirurgia , Fígado/cirurgia , Imageamento por Ressonância Magnética , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Humanos , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagemRESUMO
This paper designed an automatic robotic puncture system for accurate liver cancer ablation based on optical surgical navigation. The near-infrared optical surgical navigation system we constructed for liver ablation was applied to carry out surgical planning and simulation, the near-infrared cameras dynamically tracked the current position of puncture needle relative to the location of the patient's anatomy, then guided the surgery robot to position precisely in three-dimensional space and performed the surgery.
Assuntos
Neoplasias Hepáticas/cirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Agulhas , Punções , Cirurgia Assistida por ComputadorRESUMO
BACKGROUND: Underutilization of potential curative surgical treatment remains a problem in the management of hepatocellular carcinoma (HCC). Demographic and socioeconomic disparities continue to be important factors impacting utilization patterns, and exact mechanisms underlying these disparities remain largely unclarified. Focusing on these mechanisms provides us with a potential approach to improve survival of HCC patients. METHODS: We performed a retrospective cohort study using the Surveillance, Epidemiology, and End Results Database to assess patients with early stage HCC diagnosed between January 2004 and December 2012. Demographic and socioeconomic factors were analyzed to assess associations with utilization of treatment, stage of presentation, and disease-specific survival by means of multinominal and Cox regression. RESULTS: A total of 13,694 patients were included in the analysis of which only 6239 (45.6%) underwent surgical treatment for early stage HCC. Surgical treatment options consisted of 1445 liver resections (10.6%), 2121 liver transplantations (15.5%), and 2673 liver ablations (19.5%). The rate of surgical treatment fell from 56.1% in 2004 to 37.8% in 2012. Compared with no surgical therapy, African Americans were less likely to undergo liver transplantation (relative risk ratio [RRR] = 0.54; 95% confidence interval [CI], 0.36-0.79) than Caucasian patients and more likely to undergo surgical resection (RRR = 1.67; 95% CI, 1.13-2.48). Patients from the Pacific West were less likely to be transplanted versus patients from the Southeast (RRR = 0.68; 95% CI, 0.50-0.93). Also, patients who were married (RRR = 2.44; 95% CI, 1.96-3.04) or had health insurance (RRR = 4.74; 95% CI, 1.66-13.6) were more likely to receive liver transplantation. Young age (hazard ratio = 1.02; 95% CI, 1.00-1.03; P = 0.025) and positive marital status (hazard ratio = 0.71; 95% CI, 0.55-0.92; P = 0.010) both were independently associated with increased disease-specific survival. CONCLUSIONS: An increasing proportion of patients with early stage HCC did not undergo surgical therapy between 2004 and 2012. Demographic and socioeconomic factors were associated with different treatment modality utilization after controlling for available confounders. Of these factors, age and marital status were independently associated with increased disease-specific survival.
Assuntos
Carcinoma Hepatocelular/cirurgia , Disparidades em Assistência à Saúde/estatística & dados numéricos , Hepatectomia/estatística & dados numéricos , Neoplasias Hepáticas/cirurgia , Transplante de Fígado/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Feminino , Disparidades em Assistência à Saúde/economia , Disparidades em Assistência à Saúde/etnologia , Humanos , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Programa de SEER , Fatores Socioeconômicos , Estados UnidosRESUMO
BACKGROUND: For the treatment of both primary and metastatic liver tumors, laparoscopic parenchyma-sparing surgery is advocated to reduce postoperative liver failure and facilitate reoperation in the case of recurrence. However, atypical and wedge resections are associated with a higher amount of intraoperative bleeding than are anatomical resections, and such bleeding is known to affect short- and long-term outcomes. Beyond the established role of radiofrequency and microwave ablation in the setting of inoperable liver tumors, the application of thermoablative energy along the plane of the liver surface to be transected results in a zone of coagulative necrosis, possibly minimizing bleeding of the cut liver surface during parenchymal transection. METHODS: From January 2013 to March 2016, a total of 20 selected patients underwent laparoscopic ultrasound-guided liver resection with thermoablative precoagulation of the transection line. RESULTS: During a period of 38 months, 50 laparoscopic thermoablative procedures were performed. Colorectal liver metastases were the most frequent diagnosis. Seventy-two percent of the nodules were removed using parenchymal transection with radiofrequency-precoagulation, while microwave-precoagulation was performed for 20 % of the resected nodules. The remaining 8 % of the nodules were treated by thermoablation alone. The hepatic pedicle was intermittently clamped in six patients. The mean blood loss was 290 mL, and four patients required perioperative transfusions. CONCLUSIONS: Precoagulation-assisted parenchyma-sparing laparoscopic liver surgery can get minimal blood loss during parenchymal transection and lower the need for perioperative transfusions, providing a nonquantifiable margin of oncological safety on the remaining liver. Additional results from larger series are advocated to confirm these preliminary data.
Assuntos
Eletrocoagulação , Hepatectomia/métodos , Laparoscopia , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/cirurgia , Idoso , Idoso de 80 Anos ou mais , Perda Sanguínea Cirúrgica/prevenção & controle , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Ultrassonografia de IntervençãoRESUMO
BACKGROUND: The aim of this study was to evaluate whether enhanced three-dimensional ultrasound (US) could increase the accuracy and efficacy for liver tumor identification and needle placement. METHODS: In a prospective study, 30 surgeons of various training levels were evaluated for lesion identification success and accuracy of needle placement. All surgeons were evaluated for time (seconds) to identify the liver lesions in an artificial model and placement of needles after review of a 3-phase computed tomography scan of the liver, first using standard B-mode US and then using E-3DUS. RESULTS: Participants included 10 hepato-pancreatico-biliary surgeons, 5 surgical fellows, 10 postgraduate years 4 and 5 surgical residents, and 5 postgraduate year-3 residents. Liver lesions were correctly identified in 73% of the cases using B-mode US alone and 100% in E-3DUS. The mean time to identification using B-mode was 51.9 s (standard deviation ± 37.1), which was significantly longer than with E-3DUS (time, 17.9 s, standard deviation ± 10.7; P = 0.002). There was significant improvement in time-to-lesion identification using E-3DUS across all training levels (P ≤ 0.002). There was also a significant reduction in time for accurate needle placement across all training levels (mean reduction of 60%, with enhanced accuracy [P = 0.001]) CONCLUSIONS: E-3DUS significantly enhances lesion identification regardless of size and enhances needle accuracy for all surgeons. This adjunctive system should be considered for both training and for all complex liver tumor ablations.
Assuntos
Imageamento Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Técnicas de Ablação/instrumentação , Humanos , Neoplasias Hepáticas/cirurgia , Modelos Anatômicos , Agulhas , Estudos Prospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios XRESUMO
BACKGROUND AND OBJECTIVES: Microwave thermosphere ablation (MTA) is a new technology that is designed to create spherical zones of ablation using a single antenna. The aim of this study is to assess the results of MTA in a large series of patients. METHODS: This was a prospective study assessing the use of MTA in patients with malignant liver tumors. The procedures were done mostly laparoscopically and ablation zones created were assessed for completeness of tumor response, spherical geometry and recurrence on tri-phasic CT scans done on follow-up. RESULTS: There were a total of 53 patients with an average of 3 tumors measuring 1.5 cm. Ablations were performed laparoscopically in all but eight patients. Morbidity was 11.3% (n = 6), and mortality zero. On postoperative scans, there was 99.3% tumor destruction. Roundness indices A, B, and transverse were 1.1, 1.0, and 0.9, respectively. At a median follow-up of 4.5 months, incomplete ablation was seen in 1 of 149 lesions treated (0.7%) and local tumor recurrence in 1 lesion (0.7%). CONCLUSIONS: The results of this series confirm the safety and feasibility of MTA technology. The 99.3% rate of complete tumor ablation and low rate of local recurrence at short-term follow up are promising.
Assuntos
Técnicas de Ablação/métodos , Carcinoma Hepatocelular/cirurgia , Hipertermia Induzida , Laparoscopia , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Técnicas de Ablação/instrumentação , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
Background: In recent years, high intensity focused ultrasound (HIFU) has gained increasing clinical interest as a non-invasive method for local therapy of liver malignancies. HIFU treatment of tumours and metastases in the liver dome is limited due to the adjacent ultrasound blocking lung. One-lung flooding (OLF) enables complete sonography of lung and adjoining organs including liver. HIFU liver ablation passing through the flooded lung could enable a direct intercostal beam path and thus improve dose deposition in liver. In this study, we evaluate the feasibility of an ultrasound guided transthoracic, transpulmonary HIFU ablation of liver using OLF. Methods: After right-side lung flooding, ultrasound guided HIFU was applied transthoracic- transpulmonary into liver to create thermal lesions in three pigs. The HIFU beam was targeted five times into liver, two times at the liver surface and three times deeper into the tissue. During autopsy examinations of lung, diaphragm and liver located in the HIFU path were performed. The focal liver lesions and lung tissue out of the beam path were examined histologically. Results: Fifteen thermal liver lesions were generated by transpulmonary HIFU sonication in all targeted regions. The lesions appeared well-demarcated in grey color with a cigar-shaped configuration. The mean length and width of the superficial and deeper lesions were 15.8 mm (range: 13-18 mm) and 5.8 mm (range: 5-7 mm), and 10.9 mm (range: 9-13 mm) and 3.3 mm (range: 2-5 mm), respectively. Histopathological, all liver lesions revealed a homogeneous thermal necrosis lacking vitality. There were no signs of damage of the overlying diaphragm and lung tissue. Conclusions: Flooded lung is a suitable pathway for applying HIFU to the liver, thus enabling a transthoracic, transpulmonary approach. The enlarged acoustic window could enhance the ablation speed for targets in the hepatic dome.
Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Fígado/fisiologia , Fígado/cirurgia , Pulmão/cirurgia , Animais , Estudos de Viabilidade , Feminino , Humanos , Fígado/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Suínos , UltrassonografiaRESUMO
BACKGROUND: Image-guided systems have recently been introduced for their application in liver surgery. We aimed to identify and propose suitable indications for image-guided navigation systems in the domain of open oncologic liver surgery and, more specifically, in the setting of liver resection with and without microwave ablation. METHOD: Retrospective analysis was conducted in patients undergoing liver resection with and without microwave ablation using an intraoperative image-guided stereotactic system during three stages of technological development (accuracy: 8.4 ± 4.4 mm in phase I and 8.4 ± 6.5 mm in phase II versus 4.5 ± 3.6 mm in phase III). It was evaluated, in which indications image-guided surgery was used according to the different stages of technical development. RESULTS: Between 2009 and 2013, 65 patients underwent image-guided surgical treatment, resection alone (n = 38), ablation alone (n = 11), or a combination thereof (n = 16). With increasing accuracy of the system, image guidance was progressively used for atypical resections and combined microwave ablation and resection instead of formal liver resection (p < 0.0001). CONCLUSION: Clinical application of image guidance is feasible, while its efficacy is subject to accuracy. The concept of image guidance has been shown to be increasingly efficient for selected indications in liver surgery. While accuracy of available technology is increasing pertaining to technological advancements, more and more previously untreatable scenarios such as multiple small, bilobar lesions and so-called vanishing lesions come within reach.
Assuntos
Hepatectomia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Cirurgia Assistida por Computador , Idoso , Feminino , Humanos , Imageamento Tridimensional , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , UltrassonografiaRESUMO
BACKGROUND: Laparoscopic liver ablation therapy can be used for the treatment of primary and secondary liver malignancy. The increased incidence of cancer recurrence associated with this approach, has been attributed to the inability of monitoring the extent of ablated liver tissue. METHODS: The feasibility of assessing liver ablation with probe-based confocal laser endomicroscopy (CLE) was studied in a porcine model of laparoscopic microwave liver ablation. Following the intravenous injection of the fluorophores fluorescein and indocyanine green, CLE images were recorded at 488 nm and 660 nm wavelength and compared to liver histology. Statistical analysis was performed to assess if fluorescence intensity change can predict the presence of ablated liver tissue. RESULTS: CLE imaging of fluorescein at 488 nm provided good visualization of the hepatic microvasculature; whereas, CLE imaging of indocyanine green at 660 nm enabled detailed visualization of hepatic sinusoid architecture and interlobular septations. Fluorescence intensity as measured in relative fluorescence units was found to be 75-100% lower in ablated compared to healthy liver regions. General linear mixed modeling and ROC analysis found the decrease in fluorescence to be statistically significant. CONCLUSION: Laparoscopic, dual wavelength CLE imaging using two different fluorophores enables clinically useful visualization of multiple liver tissue compartments, in greater detail than is possible at a single wavelength. CLE imaging may provide valuable intraoperative information on the extent of laparoscopic liver ablation.
Assuntos
Técnicas de Ablação/métodos , Hepatectomia/métodos , Fígado/cirurgia , Micro-Ondas/uso terapêutico , Animais , Endoscopia , Estudos de Viabilidade , Feminino , Fluoresceína , Corantes Fluorescentes , Verde de Indocianina , Modelos Lineares , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Fígado/patologia , Microscopia Confocal/métodos , SuínosRESUMO
OBJECTIVE: Irreversible electroporation (IRE) is a new ablation modality. Our purpose was to describe the effectiveness and the safety of the treatment and to evaluate the magnetic resonance imaging (MRI), computed tomography (CT) and contrast-enhanced ultrasound (CEUS) diagnostic accuracy in HCC patients treated with IRE at 1-, 3-, and 6-month follow-up. MATERIALS AND METHODS: In an 18-month period, we treated 24 HCC lesions in 20 patients unfit for surgery. MRI, CT and CEUS were performed before and one, 3 and 6 month after IRE. We employed the liver-specific contrast medium Primovist (gadolinium ethoxybenzyl dimeglumine) in MRI. After IRE the lesions were classified as responders or non-responders to the treatment according to the mRECIST and the complications were recorded. We evaluated the size, shape, signal intensity (T1-W, T2-W, and DWI) in MRI, dynamic contrast enhancement pattern for CEUS, CT and MRI and signal behavior during the liver-specific phase for MRI. RESULTS: According to mRECIST, at 1 month MRI and CEUS showed a complete response (CR) in 91.7% of cases (22/24) tumors, while there was partial response (PR) in the remaining 2/24 (8.3%) treated nodules; in CT study all ablated zone appeared as necrotic (CR 100%). The residual viable tumor in MRI and in CEUS study had similar diameter (10 mm). No new HCC were identified from MRI, CT or CEUS. At 3 months MRI and CEUS showed the same results seen after 1 month from the treatment. Twenty-two necrotic lesions, and 2 residual tumors were found (CR = 91.7% and PD = 8.3%). In MRI study the two cases of residual tumor tissue had a diameter of 11 and 12 mm each. At CEUS the diameter of residual HCC was similar to the diameter at 1 month. CT showed 23 necrotic areas and one residual viable tissue in the treated zone, with a diameter of 10 mm (CR = 95.3% and PD = 4.7%). No new foci of HCC were identified from all imaging studies. At 6 months MRI, CEUS, and CT showed 22 necrotic lesions and 2 residual tumors in ablated zone (CR = 91.7% and PD = 8.3%). At MRI the diameters of the two residual viable HCCs were 12 and 14 mm, at CEUS the diameters were 11 and 12 mm, while at CT the diameters were 10 and 10 mm. No statistical difference was evaluated between CR, PR, PD percentage values for MRI, CT and CEUS (p value > 0.05 at Chi-square test). No major vascular complication was recorded after IRE. Six out of 20 patients (30%) showed a transient hepatic intensity difference (THID) area within the normal liver parenchyma adjacent to the treated lesions. Two of the 20 patients (10%) showed an absent concentration of liver-specific contrast medium around the ablation zone. Two patients developed complications, consisting in a peripheral arteriovenous shunt and a segmental dilation of the intrahepatic biliary ducts. We found no statistically significant difference in morphology, size (variation in the largest diameter), signal intensity in T1-weighted images, in T2-weighted images, in DWI and in the related map of the apparent diffusion coefficient (ADC), presence or absence of contrast enhanced during the arterial, portal, and late phase in MRI, CT, and CEUS, and signal characteristic during the liver-specific phase in MRI of the ablation zone at 1, 3, and 6 months. CONCLUSION: IRE is a feasible, safe and efficient modality in the treatment of patients with non-resectable HCC. We had no major complication, even when the ablated lesion was adjacent to major branches of the portal vein. All images techniques showed similar accuracy during the follow-up at 1, 3, and 6 months in the assessment ablated zone.
Assuntos
Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/tratamento farmacológico , Eletroquimioterapia , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/tratamento farmacológico , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Feminino , Seguimentos , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , UltrassonografiaRESUMO
Objective: The aim of this systematic review and meta-analysis is to identify current robotic assistance systems for percutaneous liver ablations, compare approaches, and determine how to achieve standardization of procedural concepts for optimized ablation outcomes. Background: Image-guided surgical approaches are increasingly common. Assistance by navigation and robotic systems allows to optimize procedural accuracy, with the aim to consistently obtain adequate ablation volumes. Methods: Several databases (PubMed/MEDLINE, ProQuest, Science Direct, Research Rabbit, and IEEE Xplore) were systematically searched for robotic preclinical and clinical percutaneous liver ablation studies, and relevant original manuscripts were included according to the Preferred Reporting items for Systematic Reviews and Meta-Analyses guidelines. The endpoints were the type of device, insertion technique (freehand or robotic), planning, execution, and confirmation of the procedure. A meta-analysis was performed, including comparative studies of freehand and robotic techniques in terms of radiation dose, accuracy, and Euclidean error. Results: The inclusion criteria were met by 33/755 studies. There were 24 robotic devices reported for percutaneous liver surgery. The most used were the MAXIO robot (8/33; 24.2%), Zerobot, and AcuBot (each 2/33, 6.1%). The most common tracking system was optical (25/33, 75.8%). In the meta-analysis, the robotic approach was superior to the freehand technique in terms of individual radiation (0.5582, 95% confidence interval [CI] = 0.0167-1.0996, dose-length product range 79-2216 mGy.cm), accuracy (0.6260, 95% CI = 0.1423-1.1097), and Euclidean error (0.8189, 95% CI = -0.1020 to 1.7399). Conclusions: Robotic assistance in percutaneous ablation for liver tumors achieves superior results and reduces errors compared with manual applicator insertion. Standardization of concepts and reporting is necessary and suggested to facilitate the comparison of the different parameters used to measure liver ablation results. The increasing use of image-guided surgery has encouraged robotic assistance for percutaneous liver ablations. This systematic review analyzed 33 studies and identified 24 robotic devices, with optical tracking prevailing. The meta-analysis favored robotic assessment, showing increased accuracy and reduced errors compared with freehand technique, emphasizing the need for conceptual standardization.