Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Appl Clin Med Phys ; 22(1): 318-326, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33369008

RESUMO

PURPOSE: This study aims to evaluate the performance of four artificial intelligence-aided diagnostic systems in identifying and measuring four types of pulmonary nodules. METHODS: Four types of nodules were implanted in a commercial lung phantom. The phantom was scanned with multislice spiral computed tomography, after which four systems (A, B, C, D) were used to identify the nodules and measure their volumes. RESULTS: The relative volume error (RVE) of system A was the lowest for all nodules, except for small ground glass nodules (SGGNs). System C had the smallest RVE for SGGNs, -0.13 (-0.56, 0.00). In the Bland-Altman test, only systems A and C passed the consistency test, P = 0.40. In terms of precision, the miss rate (MR) of system C was 0.00% for small solid nodules (SSNs), ground glass nodules (GGNs), and solid nodules (SNs) but 4.17% for SGGNs. The comparable system D MRs for SGGNs, SSNs, and GGNs were 71.30%, 25.93%, and 47.22%, respectively, the highest among all the systems. Receiver operating characteristic curve analysis indicated that system A had the best performance in recognizing SSNs and GGNs, with areas under the curve of 0.91 and 0.68. System C had the best performance for SGGNs (AUC = 0.91). CONCLUSION: Among four types nodules, SGGNs are the most difficult to recognize, indicating the need to improve higher accuracy and precision of artificial systems. System A most accurately measured nodule volume. System C was most precise in recognizing all four types of nodules, especially SGGN.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Inteligência Artificial , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X
2.
Sensors (Basel) ; 21(5)2021 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-33803297

RESUMO

When dealing with computed tomography volume data, the accurate segmentation of lung nodules is of great importance to lung cancer analysis and diagnosis, being a vital part of computer-aided diagnosis systems. However, due to the variety of lung nodules and the similarity of visual characteristics for nodules and their surroundings, robust segmentation of nodules becomes a challenging problem. A segmentation algorithm based on the fast marching method is proposed that separates the image into regions with similar features, which are then merged by combining regions growing with k-means. An evaluation was performed with two distinct methods (objective and subjective) that were applied on two different datasets, containing simulation data generated for this study and real patient data, respectively. The objective experimental results show that the proposed technique can accurately segment nodules, especially in solid cases, given the mean Dice scores of 0.933 and 0.901 for round and irregular nodules. For non-solid and cavitary nodules the performance dropped-0.799 and 0.614 mean Dice scores, respectively. The proposed method was compared to active contour models and to two modern deep learning networks. It reached better overall accuracy than active contour models, having comparable results to DBResNet but lesser accuracy than 3D-UNet. The results show promise for the proposed method in computer-aided diagnosis applications.

3.
J Ultrasound Med ; 38(5): 1361-1365, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30208217

RESUMO

Lung ultrasound (US) surface wave elastography (SWE) is a novel technique that measures superficial lung tissue elastic properties. A thin pleural fluid layer covers a lung, but its effect on lung measurements in SWE is unknown. We modeled a lung and pleural fluid with sponges and a thin layer of US transmission gel. Sponge surface wave speeds measured from SWE were compared for sponges without and with the thin US gel layer at 3 wave excitation frequencies. The comparison showed that the sponge surface wave speed measurements were not affected by the thin gel layer.


Assuntos
Líquidos Corporais/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Pulmão/diagnóstico por imagem , Pleura/diagnóstico por imagem , Imagens de Fantasmas
4.
J Appl Clin Med Phys ; 20(2): 107-113, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30667581

RESUMO

PURPOSE: To compare the dosimetric impact and treatment delivery efficacy of phase-gated volumetric modulated arc therapy (VMAT) vs amplitude-gated VMAT for stereotactic body radiation therapy (SBRT) for lung cancer by using realistic three-dimensional-printed phantoms. METHODS: Four patient-specific moving lung phantoms that closely simulate the heterogeneity of lung tissue and breathing patterns were fabricated with four planning computed tomography (CT) images for lung SBRT cases. The phantoms were designed to be bisected for the measurement of two-dimensional dose distributions by using EBT3 dosimetry film. The dosimetric accuracy of treatment under respiratory motion was analyzed with the gamma index (2%/1 mm) between the plan dose and film dose measured under phase- and amplitude-gated VMAT. For the validation of the direct usage of the real-time position management (RPM) data for respiratory motion, the relationship between the RPM signal and the diaphragm position was measured by four-dimensional CT. By using data recorded during the beam delivery of both phase- and amplitude-gated VMAT, the total time intervals were compared for each treatment mode. RESULTS: Film dosimetry showed a 5.2 ± 4.2% difference of gamma passing rate (2%/1 mm) on average between the phase- vs amplitude-gated VMAT [77.7% (72.7%-85.9%) for the phase mode and 82.9% (81.4%-86.2%) for the amplitude mode]. For delivery efficiency, frequent interruptions were observed during the phase-gated VMAT, which stopped the beam delivery and required a certain amount of time before resuming the beam. This abnormality in phase-gated VMAT caused a prolonged treatment delivery time of 366 s compared with 183 s for amplitude-gated VMAT. CONCLUSIONS: Considering the dosimetric accuracy and delivery efficacy between the gating methods, amplitude mode is superior to phase mode for gated VMAT treatment.


Assuntos
Neoplasias Pulmonares/cirurgia , Imagens de Fantasmas , Impressão Tridimensional/instrumentação , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Movimento , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Respiração
5.
J Appl Clin Med Phys ; 20(9): 86-94, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31538716

RESUMO

In proton therapy, the Bragg peak of a proton beam reportedly deteriorates when passing though heterogeneous structures such as human lungs. Previous studies have used heterogeneous random voxel phantoms, in which soft tissues and air are randomly allotted to render the phantoms the same density as human lungs, for conducting Monte Carlo (MC) simulations. However, measurements of these phantoms are complicated owing to their difficult-to-manufacture shape. In the present study, we used Voronoi tessellation to design a phantom that can be manufactured, and prepared a Voronoi lung phantom for which both measurement and MC calculations are possible. Our aim was to evaluate the effectiveness of this phantom as a new lung phantom for investigating proton beam Bragg peak deterioration. For this purpose, we measured and calculated the percentage depth dose and the distal falloff widths (DFW) passing through the phantom. For the 155 MeV beam, the measured and calculated DFW values with the Voronoi lung phantom were 0.40 and 0.39 cm, respectively. For the 200 MeV beam, the measured and calculated DFW values with the Voronoi lung phantom were both 0.48 cm. Our results indicate that both the measurements and MC calculations exhibited high reproducibility with plastinated lung sample from human body in previous studies. We found that better results were obtained using the Voronoi lung phantom than using other previous phantoms. The designed phantom may contribute significantly to the improvement of measurement precision. This study suggests that the Voronoi lung phantom is useful for simulating the effects of the heterogeneous structure of lungs on proton beam deterioration.


Assuntos
Algoritmos , Pulmão/efeitos da radiação , Método de Monte Carlo , Imagens de Fantasmas , Impressão Tridimensional/instrumentação , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Simulação por Computador , Humanos , Dosagem Radioterapêutica
6.
Artigo em Inglês | MEDLINE | ID: mdl-39055486

RESUMO

Several lung diseases lead to alterations in regional lung mechanics, including ventilator- and radiation-induced lung injuries. Such alterations can lead to localized underventilation of the affected areas, resulting in the overdistension of the surrounding healthy regions. Thus, there has been growing interest in quantifying the dynamics of the lung parenchyma using regional biomechanical markers. Image registration through dynamic imaging has emerged as a powerful tool to assess lung parenchyma's kinematic and deformation behaviors during respiration. However, the difficulty in validating the image registration estimation of lung deformation, primarily due to the lack of ground-truth deformation data, has limited its use in clinical settings. To address this barrier, we developed a method to convert a finite-element (FE) mesh of the lung into a phantom computed tomography (CT) image, advantageously possessing ground-truth information included in the FE model. The phantom CT images generated from the FE mesh replicated the geometry of the lung and large airways that were included in the FE model. Using spatial frequency response, we investigated the effect of " imaging parameters" such as voxel size (resolution) and proximity threshold values on image quality. A series of high-quality phantom images generated from the FE model simulating the respiratory cycle will allow for the validation and evaluation of image registration-based estimations of lung deformation. In addition, the present method could be used to generate synthetic data needed to train machine-learning models to estimate kinematic biomarkers from medical images that could serve as important diagnostic tools to assess heterogeneous lung injuries.

7.
Phys Med Biol ; 68(23)2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-37669669

RESUMO

Objective.To experimentally validate a method to create continuous time-resolved estimated synthetic 4D-computed tomography datasets (tresCTs) based on orthogonal cine MRI data for lung cancer treatments at a magnetic resonance imaging (MRI) guided linear accelerator (MR-linac).Approach.A breathing porcine lung phantom was scanned at a CT scanner and 0.35 T MR-linac. Orthogonal cine MRI series (sagittal/coronal orientation) at 7.3 Hz, intersecting tumor-mimicking gelatin nodules, were deformably registered to mid-exhale 3D-CT and 3D-MRI datasets. The time-resolved deformation vector fields were extrapolated to 3D and applied to a reference synthetic 3D-CT image (sCTref), while accounting for breathing phase-dependent lung density variations, to create 82 s long tresCTs at 3.65 Hz. Ten tresCTs were created for ten tracked nodules with different motion patterns in two lungs. For each dataset, a treatment plan was created on the mid-exhale phase of a measured ground truth (GT) respiratory-correlated 4D-CT dataset with the tracked nodule as gross tumor volume (GTV). Each plan was recalculated on the GT 4D-CT, randomly sampled tresCT, and static sCTrefimages. Dose distributions for corresponding breathing phases were compared in gamma (2%/2 mm) and dose-volume histogram (DVH) parameter analyses.Main results.The mean gamma pass rate between all tresCT and GT 4D-CT dose distributions was 98.6%. The mean absolute relative deviations of the tresCT with respect to GT DVH parameters were 1.9%, 1.0%, and 1.4% for the GTVD98%,D50%, andD2%, respectively, 1.0% for the remaining nodulesD50%, and 1.5% for the lungV20Gy. The gamma pass rate for the tresCTs was significantly larger (p< 0.01), and the GTVD50%deviations with respect to the GT were significantly smaller (p< 0.01) than for the sCTref.Significance.The results suggest that tresCTs could be valuable for time-resolved reconstruction and intrafractional accumulation of the dose to the GTV for lung cancer patients treated at MR-linacs in the future.


Assuntos
Neoplasias Pulmonares , Humanos , Animais , Suínos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Imageamento por Ressonância Magnética , Pulmão , Tomografia Computadorizada Quadridimensional/métodos , Imagem Cinética por Ressonância Magnética , Planejamento da Radioterapia Assistida por Computador/métodos
8.
J Biomed Opt ; 27(7)2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34725995

RESUMO

SIGNIFICANCE: Gas in scattering media absorption spectroscopy (GASMAS) enables noninvasive gas sensing in the body. It is developing as a tool for diagnosis and monitoring of respiratory conditions in neonates. Phantom models with relevant features to the clinical translation of GASMAS technology are necessary to understand technical challenges and potential applications of this technique. State-of-the-art phantoms designed for this purpose have focused on the optical properties and anthropomorphic geometry of the thorax, contributing to the source-detector placement, design, and optimization. Lung phantom mimicking the alveolar anatomy has not been included in the existent models due to the inherent complexity of the tissue. We present a simplified model that recreates inflated alveoli embedded in lung phantom. AIM: The goal of this study was to build a lung model with air-filled structures mimicking inflated alveoli surrounded by optical phantom with accurate optical properties (µa = 0.50 cm - 1 and µs'=5.4 cm-1) and physiological parameters [37°C and 100% relative humidity (RH)], and to control the air volume within the phantom to demonstrate the feasibility of GASMAS in sensing changes in pulmonary air volume. APPROACH: The lung model was built using a capillary structure with analogous size to alveolar units. Part of the capillaries were filled with liquid lung optical phantom to recreate scattering and absorption, whereas empty capillaries mimicked air filled alveoli. The capillary array was placed inside a custom-made chamber that maintained pulmonary temperature and RH. The geometry of the chamber permitted the placement of the laser head and detector of a GASMAS bench top system (MicroLab Dual O2 / H2O), to test the changes in volume of the lung model in transmittance geometry. RESULTS: The lung tissue model with air volume range from 6.89 × 10 - 7 m3 to 1.80 × 10 - 3 m3 was built. Two measurement sets, with 10 different capillary configurations each, were arranged to increase or decrease progressively (in steps of 3.93 × 10 - 8 m3) the air volume in the lung model. The respective GASMAS data acquisition was performed for both data sets. The maximum absorption signal was obtained for configurations with the highest number of air-filled capillaries and decreased progressively when the air spaces were replaced by capillaries filled with liquid optical phantom. Further studies are necessary to define the minimum and maximum volume of air that can be measured with GASMAS-based devices for different source-detector geometries. CONCLUSIONS: The optical properties and the structure of tissue from the respiratory zone have been modeled using a simplified capillary array immersed in a controlled environment chamber at pulmonary temperature and RH. The feasibility of measuring volume changes with GASMAS technique has been proven, stating a new possible application of GASMAS technology in respiratory treatment and diagnostics.


Assuntos
Pulmão , Oxigênio , Humanos , Umidade , Recém-Nascido , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Temperatura
9.
Phys Med Biol ; 66(17)2021 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-34293737

RESUMO

Proton therapy treatment for lungs remains challenging as images enabling the detection of inter- and intra-fractional motion, which could be used for proton dose adaptation, are not readily available. 4D computed tomography (4DCT) provides high image quality but is rarely available in-room, while in-room 4D cone beam computed tomography (4DCBCT) suffers from image quality limitations stemming mostly from scatter detection. This study investigated the feasibility of using virtual 4D computed tomography (4DvCT) as a prior for a phase-per-phase scatter correction algorithm yielding a 4D scatter corrected cone beam computed tomography image (4DCBCTcor), which can be used for proton dose calculation. 4DCT and 4DCBCT scans of a porcine lung phantom, which generated reproducible ventilation, were acquired with matching breathing patterns. Diffeomorphic Morphons, a deformable image registration algorithm, was used to register the mid-position 4DCT to the mid-position 4DCBCT and yield a 4DvCT. The 4DCBCT was reconstructed using motion-aware reconstruction based on spatial and temporal regularization (MA-ROOSTER). Successively for each phase, digitally reconstructed radiographs of the 4DvCT, simulated without scatter, were exploited to correct scatter in the corresponding CBCT projections. The 4DCBCTcorwas then reconstructed with MA-ROOSTER using the corrected CBCT projections and the same settings and deformation vector fields as those already used for reconstructing the 4DCBCT. The 4DCBCTcorand the 4DvCT were evaluated phase-by-phase, performing proton dose calculations and comparison to those of a ground truth 4DCT by means of dose-volume-histograms (DVH) and gamma pass-rates (PR). For accumulated doses, DVH parameters deviated by at most 1.7% in the 4DvCT and 2.0% in the 4DCBCTcorcase. The gamma PR for a (2%, 2 mm) criterion with 10% threshold were at least 93.2% (4DvCT) and 94.2% (4DCBCTcor), respectively. The 4DCBCTcortechnique enabled accurate proton dose calculation, which indicates the potential for applicability to clinical 4DCBCT scans.


Assuntos
Prótons , Algoritmos , Animais , Galinhas , Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada Quadridimensional , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares , Masculino , Imagens de Fantasmas , Suínos
10.
Med Phys ; 47(9): 4502-4508, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32452027

RESUMO

PURPOSE: Between July 2013 and August 2019, 22% of the imaging and radiation oncology core (IROC) spine, and 15% of the moving lung phantom irradiations have failed to meet established acceptability criteria. The spine phantom simulates a highly modulated stereotactic body radiation therapy (SBRT) case, whereas the lung phantom represents a low-to-none modulation moving target case. In this study, we assessed the contribution of dose calculation errors to these phantom results and evaluated their effects on failure rates. METHODS: We evaluated dose calculation errors by comparing the calculation accuracy of various institutions' treatment planning systems (TPSs) vs IROC-Houston's previously established independent dose recalculation system (DRS). Each calculation was compared with the measured dose actually delivered to the phantom; cases in which the recalculation was more accurate were interpreted as a deficiency in the institution's TPS. A total of 258 phantom irradiation plans (172 lung and 86 spine) were recomputed. RESULTS: Overall, the DRS performed better than the TPSs in 47% of the spine phantom cases. However, the DRS was more accurate in 93% of failing spine phantom cases (with an average improvement of 2.35%), indicating a deficiency in the institution's treatment planning system. Deficiencies in dose calculation accounted for 60% of the overall discrepancy between measured and planned doses among spine phantoms. In contrast, lung phantom DRS calculations were more accurate in only 35% and 42% of all and failing lung phantom cases respectively, indicating that dose calculation errors were not substantially present. These errors accounted for only 30% of the overall discrepancy between measured and planned doses. CONCLUSIONS: Dose calculation errors are common and substantial in IROC spine phantom irradiations, highlighting a major failure mode in this phantom and in clinical treatment management of these cases. In contrast, dose calculation accuracy had only a minimal contribution to failing lung phantom results, indicating that other failure modes drive problems with this phantom and similar clinical treatments.


Assuntos
Radioterapia (Especialidade) , Radioterapia de Intensidade Modulada , Algoritmos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
11.
Phys Med ; 76: 16-27, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32569953

RESUMO

PURPOSE: To validate the accuracy of 4D Monte Carlo (4DMC) simulations to calculate dose deliveries to a deforming anatomy in the presence of realistic respiratory motion traces. A previously developed deformable lung phantom comprising an elastic tumor was modified to enable programming of arbitrary motion profiles. 4D simulations of the dose delivered to the phantom were compared with the measurements. METHODS: The deformable lung phantom moving with irregular breathing patterns was irradiated using static and VMAT beam deliveries. Using the RADPOS 4D dosimetry system, point doses were measured inside and outside the tumor. Dose profiles were acquired using films along the motion path of the tumor (S-I). In addition to dose measurements, RADPOS was used to record the motion of the tumor during dose deliveries. Dose measurements were then compared against 4DMC simulations with EGSnrc/4DdefDOSXYZnrc using the recorded tumor motion. RESULTS: The agreements between dose profiles from measurements and simulations were determined to be within 2%/2 mm. Point dose agreements were within 2σ of experimental and/or positional/dose reading uncertainties. 4DMC simulations were shown to accurately predict the sensitivity of delivered dose to the starting phase of breathing motions. We have demonstrated that our 4DMC method, combined with RADPOS, can accurately simulate realistic dose deliveries to a deforming anatomy moving with realistic breathing traces. This 4DMC tool has the potential to be used as a quality assurance tool to verify treatments involving respiratory motion. Adaptive treatment delivery is another area that may benefit from the potential of this 4DMC tool.


Assuntos
Neoplasias Pulmonares , Radiometria , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Respiração
12.
Med Phys ; 46(5): 1995-2005, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30919974

RESUMO

PURPOSE: Lung motion phantoms used to validate radiotherapy motion management strategies have fairly simplistic designs that do not adequately capture complex phenomena observed in human respiration such as external and internal deformation, variable hysteresis and variable correlation between different parts of the thoracic anatomy. These limitations make reliable evaluation of sophisticated motion management techniques quite challenging. In this work, we present the design and implementation of a programmable, externally and internally deformable lung motion phantom that allows for a reproducible change in external-internal and internal-internal correlation of embedded markers. METHODS: An in-house-designed lung module, made from natural latex foam was inserted inside the outer shell of a commercially available lung phantom (RSD, Long Beach, CA, USA). Radiopaque markers were placed on the external surface and embedded into the lung module. Two independently programmable high-precision linear motion actuators were used to generate primarily anterior-posterior (AP) and primarily superior-inferior (SI) motion in a reproducible fashion in order to enable (a) variable correlation between the displacement of interior volume and the exterior surface, (b) independent changes in the amplitude of the AP and SI motions, and (c) variable hysteresis. The ability of the phantom to produce complex and variable motion accurately and reproducibly was evaluated by programming the two actuators with mathematical and patient-recorded lung tumor motion traces, and recording the trajectories of various markers using kV fluoroscopy. As an example application, the phantom was used to evaluate the performance of lung motion models constructed from kV fluoroscopy and 4DCT images. RESULTS: The phantom exhibited a high degree of reproducibility and marker motion ranges were reproducible to within 0.5 mm. Variable correlation was observed between the displacements of internal-internal and internal-external markers. The SI and AP components of motion of a specific marker had a correlation parameter that varied from -11 to 17. Monitoring a region of interest on the phantom's surface to estimate internal marker motion led to considerably lower uncertainties than when a single point was monitored. CONCLUSIONS: We successfully designed and implemented a programmable, externally and internally deformable lung motion phantom that allows for a reproducible change in external-internal and internal-internal correlation of embedded markers.


Assuntos
Fluoroscopia/métodos , Neoplasias Pulmonares/radioterapia , Pulmão/efeitos da radiação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Técnicas de Imagem de Sincronização Respiratória/métodos , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Movimento , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Respiração
13.
Radiat Oncol ; 14(1): 108, 2019 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-31208439

RESUMO

PURPOSE: The purpose of this study is to evaluate the impact of two methods of reporting planned dose distributions on the Gamma analysis pass rates for comparison with measured 2D film dose and simulated delivered 3D dose for proton pencil beam scanning treatment of the Imaging and Radiation Oncology Core (IROC) proton lung and liver mobile phantoms. METHODS AND MATERIALS: Four-dimensional (4D) computed-tomography (CT) image sets were acquired for IROC proton lung and liver mobile phantoms, which include dosimetry inserts that contains targets, thermoluminescent dosimeters and EBT2 films for plan dose verification. 4DCT measured fixed motion magnitudes were 1.3 and 1.0 cm for the lung and liver phantoms, respectively. To study the effects of motion magnitude on the Gamma analysis pass rate, three motion magnitudes for each phantom were simulated by creating virtual 4DCT image sets with motion magnitudes scaled from the scanned phantom motion by 50, 100, and 200%. The internal target volumes were contoured on the maximum intensity projection CTs of the 4DCTs for the lung phantom and on the minimum intensity projection CTs of the 4DCTs for the liver phantom. Treatment plans were optimized on the average intensity projection (AVE) CTs of the 4DCTs using the RayStation treatment planning system. Plan doses were calculated on the AVE CTs, which was defined as the planned AVE dose (method one). Plan doses were also calculated on all 10 phase CTs of the 4DCTs and were registered using target alignment to and equal-weight-summed on the 50% phase (T50) CT, which was defined as the planned 4D dose (method two). The planned AVE doses and 4D doses for phantom treatment were reported to IROC, and the 2D-2D Gamma analysis pass rates for measured film dose relative to the planned AVE and 4D doses were compared. To evaluate motion interplay effects, simulated delivered doses were calculated for each plan by sorting spots into corresponding respiratory phases using spot delivery time recorded in the log files by the beam delivery system to calculate each phase dose and accumulate dose to the T50 CTs. Ten random beam starting phases were used for each beam to obtain the range of the simulated delivered dose distributions. 3D-3D Gamma analyses were performed to compare the planned 4D/AVE doses with simulated delivered doses. RESULTS: The planned 4D dose matched better with the measured 2D film dose and simulated delivered 3D dose than the planned AVE dose. Using planned 4D dose as institution reported planned dose to IROC improved IROC film dose 2D-2D Gamma analysis pass rate from 92 to 96% on average for three films for the lung phantom (7% 5 mm), and from 92 to 94% in the sagittal plane for the liver phantom (7% 4 mm), respectively, compared with using the planned AVE dose. The 3D-3D Gamma analysis (3% 3 mm) pass rate showed that the simulated delivered doses for lung and liver phantoms using 10 random beam starting phases for each delivered beam matched the planned 4D dose significantly better than the planned AVE dose for phantom motions larger than 1 cm (p ≤ 0.04). CONCLUSIONS: It is recommended to use the planned 4D dose as the institution reported planned dose to IROC to compare with the measured film dose for proton mobile phantoms to improve film Gamma analysis pass rate in the IROC credentialing process.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Fígado/efeitos da radiação , Pulmão/efeitos da radiação , Movimento , Imagens de Fantasmas , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Respiração
14.
Ultrasound Med Biol ; 44(11): 2400-2405, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30077412

RESUMO

Lung ultrasound surface wave elastography (LUSWE) is a novel technique used to measure superficial lung tissue stiffness. A phantom study was carried out in the study described here to evaluate the application of LUSWE to assess lung water for pulmonary edema. A lung phantom model with cellulose sponge was used; various volumes of water were injected into the sponge to model lung water. Shaker-generated surface wave propagation on the sponge surface was recorded by a 10-MHz ultrasound probe at three shaker frequencies: 100, 150 and 200Hz. Surface wave speeds were calculated but did not exhibit dependence on the volume of injected water. However, the shear viscosity of the sponge increased with water content, and shear elasticity also exhibited a subtle increase. This study suggests that sponge viscoelasticity might change with the water content, which can be detected by LUSWE.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Imagens de Fantasmas , Edema Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Edema Pulmonar/fisiopatologia
15.
Phys Med ; 51: 81-90, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29776740

RESUMO

PURPOSE: To verify the accuracy of 4D Monte Carlo (MC) simulations, using the 4DdefDOSXYZnrc user code, in a deforming anatomy. We developed a tissue-equivalent and reproducible deformable lung phantom and evaluated 4D simulations of delivered dose to the phantom by comparing calculations against measurements. METHODS: A novel deformable phantom consisting of flexible foam, emulating lung tissue, inside a Lucite external body was constructed. A removable plug, containing an elastic tumor that can hold film and other dosimeters, was inserted in the phantom. Point dose and position measurements were performed inside and outside the tumor using RADPOS 4D dosimetry system. The phantom was irradiated on an Elekta Infinity linac in both stationary and moving states. The dose delivery was simulated using delivery log files and the phantom motion recorded with RADPOS. RESULTS: Reproducibility of the phantom motion was determined to be within 1 mm. The phantom motion presented realistic features like hysteresis. MC calculations and measurements agreed within 2% at the center of tumor. Outside the tumor agreements were better than 5% which were within the positional/dose reading uncertainties at the measurement points. More than 94% of dose points from MC simulations agreed within 2%/2 mm compared to film measurements. CONCLUSION: The deformable lung phantom presented realistic and reproducible motion characteristics and its use for verification of 4D dose calculations was demonstrated. Our 4DMC method is capable of accurate calculations of the realistic dose delivered to a moving and deforming anatomy during static and dynamic beam delivery techniques.


Assuntos
Tomografia Computadorizada Quadridimensional/instrumentação , Método de Monte Carlo , Imagens de Fantasmas , Pulmão/anatomia & histologia , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Doses de Radiação , Respiração
16.
Med Dosim ; 41(2): 113-7, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26778011

RESUMO

Radiation treatment requires high accuracy to protect healthy organs and destroy the tumor. However, tumors located near the diaphragm constantly move during treatment. Respiration-gated radiotherapy has significant potential for the improvement of the irradiation of tumor sites affected by respiratory motion, such as lung and liver tumors. To measure and minimize the effects of respiratory motion, a realistic deformable phantom is required for use as a gold standard. The purpose of this study was to develop and study the characteristics of a deformable moving lung (DML) phantom, such as simulation, tissue equivalence, and rate of deformation. The rate of change of the lung volume, target deformation, and respiratory signals were measured in this study; they were accurately measured using a realistic deformable phantom. The measured volume difference was 31%, which closely corresponds to the average difference in human respiration, and the target movement was - 30 to + 32mm. The measured signals accurately described human respiratory signals. This DML phantom would be useful for the estimation of deformable image registration and in respiration-gated radiotherapy. This study shows that the developed DML phantom can exactly simulate the patient׳s respiratory signal and it acts as a deformable 4-dimensional simulation of a patient׳s lung with sufficient volume change.


Assuntos
Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas , Respiração , Humanos , Movimento (Física) , Simulação de Paciente , Volume de Ventilação Pulmonar
17.
Radiother Oncol ; 121(2): 328-334, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27817945

RESUMO

BACKGROUND AND PURPOSE: The objective of this study was to compare the latest respiratory motion-management strategies, namely the internal-target-volume (ITV) concept, the mid-ventilation (MidV) principle, respiratory gating and dynamic couch tracking. MATERIALS AND METHODS: An anthropomorphic, deformable and dynamic lung phantom was used for the dosimetric validation of these techniques. Stereotactic treatments were adapted to match the techniques and five distinct respiration patterns, and delivered to the phantom while radiographic film measurements were taken inside the tumor. To report on tumor coverage, these dose distributions were used to calculate mean doses (Dmean), changes in homogeneity indices (ΔH2-98), gamma agreement, and areas covered by the planned minimum dose (A>Dmin). RESULTS: All techniques achieved good tumor coverage (A>Dmin>99.0%) and minor changes in Dmean (±3.2%). Gating and tracking strategies showed superior results in gamma agreement and ΔH2-98 compared to ITV and MidV concepts, which seem to be more influenced by the interplay and the gradient effect. For lung, heart and spinal cord, significant dose differences between the four techniques were found (p<0.05), with lowest doses for gating and tracking strategies. CONCLUSION: Active motion-management techniques, such as gating or tracking, showed superior tumor dose coverage and better organ dose sparing than the passive techniques based on tumor margins.


Assuntos
Neoplasias Pulmonares/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Antropometria/métodos , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Movimento/fisiologia , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Radiometria/métodos , Dosagem Radioterapêutica , Respiração
18.
J Radiat Res ; 55(3): 600-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24385469

RESUMO

A domestic multicenter phase I study of stereotactic body radiotherapy (SBRT) for T2N0M0 non-small cell lung cancer in inoperable patients or elderly patients who refused surgery was initiated as the Japan Clinical Oncology Group trial (JCOG0702) in Japan. Prior to the clinical study, the accuracy of dose calculation in radiation treatment-planning systems was surveyed in participating institutions, and differences in the irradiating dose between the institutions were investigated. We developed a water tank-type lung phantom appropriate for verification of the exposure dose in lung SBRT. Using this water tank-type lung phantom, the dose calculated in the radiation treatment-planning system and the measured dose using a free air ionization chamber and dosimetric film were compared in a visiting survey of the seven institutions participating in the clinical study. In all participating institutions, differences between the calculated and the measured dose in the irradiation plan were as follows: the accuracy of the absolute dose in the center of the simulated tumor measured using a free air ionization chamber was within 2%, the mean gamma value was ≤ 0.47 on gamma analysis following the local dose criteria, and the pass rate was >87% for 3%/3 mm from measurement of dose distribution with dosimetric film. These findings confirmed the accuracy of delivery doses in the institutions participating in the clinical study, so that a study with integration of the institutions could be initiated.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas/normas , Radiometria/instrumentação , Radiometria/normas , Radiocirurgia/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Japão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Água
19.
Med Phys ; 32(7Part1): 2358-2362, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28493572

RESUMO

Respiratory motion is known to affect the quantitation of FDG18 uptake in lung lesions. The aim of the study was to investigate the magnitude of errors in tracer activity determination due to motion, and its dependence upon CT attenuation at different phases of the motion cycle. To estimate these errors we have compared maximum activity concentrations determined from PET/CT images of a lung phantom at rest and under simulated respiratory motion. The NEMA 2001 IEC body phantom, containing six hollow spheres with diameters 37, 28, 22, 17, 13, and 10 mm, was used in this study. To mimic lung tissue density, the phantom (excluding spheres) was filled with low density polystyrene beads and water. The phantom spheres were filled with FDG18 solution setting the target-to-background activity concentration ratio at 8:1. PET/CT data were acquired with the phantom at rest, and while it was undergoing periodic motion along the longitudinal axis of the scanner with a range of displacement being 2 cm, and a period of 5 s. The phantom at rest and in motion was scanned using manufacturer provided standard helical/clinical protocol, a helical CT scan followed by a PET emission scan. The moving phantom was also scanned using a 4D-CT protocol that provides volume image sets at different phases of the motion cycle. To estimate the effect of motion on quantitation of activities in six spheres, we have examined the activity concentration data for (a) the stationary phantom, (b) the phantom undergoing simulated respiratory motion, and (c) a moving phantom acquired with PET/4D-CT protocol in which attenuation correction was performed with CT images acquired at different phases of motion cycle. The data for the phantom at rest and in motion acquired with the standard helical/clinical protocol showed that the activity concentration in the spheres can be underestimated by as much as 75%, depending on the sphere diameter. We have also demonstrated that fluctuations in sphere's activity concentration from one PET/CT scan to another acquired with standard helical/clinical protocol can arise as a consequence of spatial mismatch between the sphere's location in PET emission and the CT data.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa