Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 500
Filtrar
Mais filtros

Eixos temáticos
Intervalo de ano de publicação
1.
Ann Surg Oncol ; 31(9): 5804-5814, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38851638

RESUMO

BACKGROUND: This study aimed to compare the benefits and safety of microwave scissors-based sutureless laparoscopic partial nephrectomy (MSLPN) with those of conventional open partial nephrectomy (cOPN). METHODS: Each kidney in nine pigs underwent MSLPN using microwave scissors (MWS) via transperitoneal laparoscopy or cOPN via retroperitoneal open laparotomy. The kidney's lower and upper poles were resected under temporary hilar-clamping. The renal calyces exposed during renal resections were sealed and transected using MWS in MSLPN and were sutured in cOPN. For MWS, the generator's power output was 60 W. Data on procedure time (PT), ischemic time (IT), blood loss (BL), normal nephron loss (NNL), and extravasation during retrograde pyelogram were compared between the two techniques. RESULTS: The authors successfully performed 22 MSLPNs and 10 cOPNs. Compared with cOPN, MSLPN was associated with significantly lower PT (median, 9.2 vs 13.0 min; p = 0.026), IT (median, 5.9 vs 9.0 min; p < 0.001), BL (median, 14.4 vs 38.3 mL; p = 0.043), and NNL (median, 7.6 vs 9.4 mm; p = 0.004). However, the extravasation rate was higher in the MSLPN group than in the cOPN group (54.5 % [n = 12] vs 30.0 % [n = 3]), albeit without a significant difference (p = 0.265). Pelvic stenosis occurred in one MSLPN procedure that involved deep lower pole resection near the kidney hilum. CONCLUSIONS: The study data show that MSLPN can improve intraoperative outcomes while reducing technical demands for selected patients with non-hilar-localized renal tumors. However, renal calyces, if violated, should be additionally sutured to prevent urine leakage.


Assuntos
Laparoscopia , Micro-Ondas , Nefrectomia , Animais , Nefrectomia/métodos , Laparoscopia/métodos , Suínos , Micro-Ondas/uso terapêutico , Complicações Pós-Operatórias/etiologia , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Duração da Cirurgia , Feminino , Instrumentos Cirúrgicos
2.
Eur Radiol ; 34(1): 236-246, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37505251

RESUMO

OBJECTIVES: To retrospectively evaluate the safety and efficacy of computed tomography (CT)-guided percutaneous microwave ablation in treating early-stage non-small cell lung cancer (NSCLC) adjacent to bronchovascular bundles. METHODS: Two hundred and thirty-one patients with early-stage NSCLC who underwent CT-guided microwave ablation of the tumor were included for analysis. Among these, 66 lesions were located adjacent to the bronchovascular bundle. Achievement of the specific ablation range (defined as the ablation zone encompassing the tumor and the adjacent vessel) was assessed after ablation. Complications and tumor progression after treatment were examined and compared between the bronchovascular bundle and non-bronchovascular bundle groups. RESULTS: A total of 231 patients were included. Overall, 1-, 2-, and 3-year local progression-free survival (LPFS) was 77.4%, 70.5%, and 63.8%, respectively. Bronchovascular bundle proximity, pure-solid tumor, tumor size, and ablation margin < 5 mm were independent risk factors for local progression in multivariate analysis. In the bronchovascular bundle group, the 1-, 2- and 3-year LPFS rates were 63.0%, 50.7%, and 43.4%, respectively; vessel proximity and specific ablation range failure were independent risk factors for local progression. Overall survival in the entire cohort was 93.0% at 1 year, 76.1% at 2 years, and 55.0% at 3 years. The incidence of postoperative complications did not significantly differ between the two groups (p > 0.05). The most common complication was pneumothorax. Severe hemoptysis did not occur. CONCLUSION: Tumor location near the bronchovascular bundles was a significant risk factor for local progression after microwave ablation. Achieving a specific ablation range may increase LPFS for these lesions. CLINICAL RELEVANCE STATEMENT: Achieving the specific ablation range may improve local efficacy for early-stage non-small cell lung cancer located adjacent to the bronchovascular bundle. KEY POINTS: • Local efficacy of percutaneous microwave ablation in treating early-stage non-small cell lung cancer was affected by bronchovascular bundle proximity. • Achieving the specific ablation range may improve local efficacy for lesions located adjacent to the bronchovascular bundle.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Ablação por Cateter , Neoplasias Pulmonares , Carcinoma de Pequenas Células do Pulmão , Humanos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Ablação por Cateter/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
3.
Eur Radiol ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39046500

RESUMO

OBJECTIVE: Ultrasound-guided thermal ablation, including radiofrequency ablation (RFA) and microwave ablation (MWA), has become one of the main options for treating benign thyroid nodules (BTNs). To assess the efficacy of thermal ablation of BTNs, we performed a systematic review and meta-analysis of relevant studies. MATERIALS AND METHODS: A comprehensive search of MEDLINE, EMBASE, and COCHRANE databases was performed up to September 25, 2023, to identify studies directly comparing RFA and MWA for pathologically proven BTNs and reporting clinical outcomes and complications. Data extraction and quality assessment were independently performed by two radiologists according to PRISMA guidelines. The analysis yielded the serial volume reduction ratios (VRRs) of ablated nodules for up to 12 months, symptom and cosmetic scores, and complications. RESULTS: This analysis included nine studies with 1305 BTNs treated by RFA and 1276 by MWA. VRRs at 1 month, 3 months, and 6 months were similar between RFA and MWA, but RFA showed a significantly higher VRR (83.3%) than MWA (76.9%) at 12 months (p = 0.02). Complication rates showed no significant difference between the two methods. Symptom and cosmetic scores significantly decreased after ablation, without a significant difference between the methods. Subgroup analysis indicated a significantly higher VRR at 12 months for RFA than for MWA for less experienced investigators (≤ 10 years), but no significant difference for more experienced investigators (> 10 years). CONCLUSION: RFA and MWA are both effective and safe methods for treating BTNs. RFA showed a higher VRR at 12 months and seems more suitable for less experienced investigators. CLINICAL RELEVANCE STATEMENT: RFA and MWA are both effective and safe treatments for BTNs, with RFA showing a higher VRR at 12 months. Both methods offer minimally invasive and reliable treatment for thyroid nodules. KEY POINTS: The most effective thermal ablation technique for BTNs remains undetermined. RFA showed a higher VRR at 12 months than MWA. Both techniques are effective for treating thyroid nodules; RFA offers greater benefits, particularly for less experienced investigators.

4.
Eur Radiol ; 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38337071

RESUMO

OBJECTIVES: To study the relationship between the ablation range and applied energy of laser ablation (LA) and microwave ablation (MWA) in papillary thyroid microcarcinoma (PTMC). METHODS: A total of 201 PTMC patients were treated with LA (n = 102) or MWA (n = 99) with single-applicator fixed ablation. The ablation range was determined by contrast-enhanced ultrasound. The ratios of ablation volume, longitudinal diameter, and orthogonal diameter to ablation energy (RAV/E, RAL/E, RAO/E) were analyzed and compared between MWA and LA. The effects of PTMC characteristics and Hashimoto's thyroiditis (HT) on ablation efficiency were evaluated by linear regression. RESULTS: The RAV/E was 0.72 (0.65-0.84) mm3/J for MWA and 0.48 (0.39-0.54) mm3/J for LA. HT was significantly correlated with RAV/E of LA (coefficient = - 0.367, p < 0.0001). RAL/E did not differ significantly between MWA and LA (MWA 0.026 mm/J, LA 0.025 mm/J; p = 0.957). However, MWA had a greater RAO/E than LA (MWA 0.014 mm/J, LA 0.012 mm/J; p < 0.0001). The plateau values of MWA and LA on the ablation orthogonal diameter were 10.7 mm and 8.69 mm, respectively. CONCLUSIONS: MWA showed a higher RAV/E than LA. More intuitively, MWA had a better ablation performance than LA on the orthogonal axis rather than the longitudinal axis. Theoretically, MWA and LA could achieve complete ablation of ≤ 6.70 mm and ≤ 4.69 mm PTMC separately by single-applicator fixed ablation considering a unilateral 2-mm safe margin. HT had a negative effect on LA but not on MWA. CLINICAL RELEVANCE STATEMENT: This study establishes strong connections between ablation energy and ablation range in papillary thyroid microcarcinoma (PTMC) in vivo, possibly contributing to the supplementation of the PTMC Ablation Consensus or Guidelines and providing a scientific basis for choosing clinical ablation parameters in PTMC. KEY POINTS: • Both microwave ablation (MWA) and laser ablation (LA) have excellent performance on the ablation longitudinal axis (easily exceeding 10 mm) for papillary thyroid microcarcinoma (PTMC). • MWA performed much better than LA on the ablation orthogonal axis. • MWA and LA are expected to achieve complete ablation of ≤ 6.70 mm and ≤ 4.69 mm PTMC separately by single-applicator fixed ablation considering a unilateral 2-mm safe margin.

5.
Eur Radiol ; 34(7): 4708-4715, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38114848

RESUMO

OBJECTIVES: To evaluate the safety and efficacy of microwave ablation (MWA) for stage I non-small cell lung cancer (NSCLC) in patients with idiopathic pulmonary fibrosis (IPF). MATERIALS AND METHODS: A retrospective single-center cohort study was conducted in patients with clinical stage I NSCLC who underwent CT-guided MWA from Nov 2016 to Oct 2021. The patients were divided into the IPF group and the non-IPF group. The primary endpoints were 90-day adverse events and hospital length of stay (HLOS). The secondary endpoints included overall survival (OS) and progression-free survival (PFS). RESULTS: A total of 107 patients (27 with IPF and 80 without IPF) were finally included for analysis. No procedure-related acute exacerbation of IPF or death occurred post-MWA. The rates of adverse events were similar between the groups (48.6% vs. 47.7%; p = 0.998). The incidence of grade 3 adverse events in the IPF group was higher than that in the non-IPF group without a significant difference (13.5% vs. 4.6%; p = 0.123). Median HLOS was 5 days in both groups without a significant difference (p = 0.078). The 1-year and 3-year OS were 85.2%/51.6% in the IPF group, and 97.5%/86.4% in the non-IPF group. The survival of patients with IPF was significantly poorer than the survival of patients without IPF (p < 0.001). There was no significant difference for PFS (p = 0.271). CONCLUSION: MWA was feasible in the treatment of stage I NSCLC in patients with IPF. IPF had an adverse effect on the survival of stage I NSCLC treated with MWA. CLINICAL RELEVANCE STATEMENT: CT-guided microwave ablation is a well-tolerated and effective potential alternative treatment for stage I non-small cell lung cancer in patients with idiopathic pulmonary fibrosis. KEY POINTS: • Microwave ablation for stage I non-small cell lung cancer was well-tolerated without procedure-related acute exacerbation of idiopathic pulmonary fibrosis and death in patients with idiopathic pulmonary fibrosis. • No differences were observed in the incidence of adverse events between patients with idiopathic pulmonary fibrosis and those without idiopathic pulmonary fibrosis after microwave ablation (48.6% vs. 47.7%; p = 0.998). • The 1-year and 3-year overall survival rates (85.2%/51.6%) in the idiopathic pulmonary fibrosis group were worse than those in the non- idiopathic pulmonary fibrosis group (97.5%/86.4%) (p < 0.001).


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Fibrose Pulmonar Idiopática , Neoplasias Pulmonares , Micro-Ondas , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Carcinoma Pulmonar de Células não Pequenas/complicações , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Idoso , Fibrose Pulmonar Idiopática/cirurgia , Fibrose Pulmonar Idiopática/complicações , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/complicações , Pessoa de Meia-Idade , Resultado do Tratamento , Estadiamento de Neoplasias , Radiografia Intervencionista/métodos , Idoso de 80 Anos ou mais
6.
Int J Hyperthermia ; 41(1): 2285705, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38269491

RESUMO

OBJECTIVE: The study aimed to compare the effectiveness and safety of ultrasound-guided microwave ablation (MWA) and percutaneous sclerotherapy (PS) for the treatment of large hepatic hemangioma (LHH). METHODS: This retrospective study included 96 patients who underwent MWA (n = 54) and PS (n = 42) as first-line treatment for LHH in three tertiary hospitals from January 2016 to December 2021. Primary outcomes were technique efficacy rate (volume reduction rate [VRR] > 50% at 12 months), symptom relief rate at 12 months and local tumor progression (LTP). Secondary outcomes included procedure time, major complications, treatment sessions, cost and one-, two-, three-year VRR. RESULTS: During a median follow-up of 36 months, the MWA group showed a higher technique efficacy rate (100% vs. 90.4%, p = .018) and symptom relief rate (100% vs. 80%, p = .123) than the PS group. The MWA group had fewer treatment sessions, higher one-, two- and three-year VRR, lower LTP rate (all p < .05), longer procedure time and higher treatment costs than the PS group (both p < .001). MWA shared a comparable major complications rate (1.8% vs. 2.4%, p = .432) with PS. After multivariate analysis, the lesion's heterogeneity and maximum diameter >8.1 cm were independent risk factors for LTP (all p < .05). In the PS group, lesions with a cumulative dose of bleomycin > 0.115 mg/cm3 had a lower risk of LTP (p = .006). CONCLUSIONS: Both MWA and PS treatments for large hepatic hemangioma are safe and effective, with MWA being superior in terms of efficacy.


Assuntos
Hemangioma , Neoplasias Hepáticas , Humanos , Escleroterapia , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Hemangioma/diagnóstico por imagem , Hemangioma/terapia , Neoplasias Hepáticas/terapia
7.
Pediatr Dermatol ; 2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38923547

RESUMO

An 8-year-old girl presented with white papules on the eyelid margins due to lipoid proteinosis. Microwave therapy resulted in significant reduction of the lesions. The case highlights a safe and effective treatment for eyelid lesions associated with lipoid proteinosis. In addition, we report two novel heterozygous variants in the extracellular matrix protein 1 (ECM1) gene.

8.
Sensors (Basel) ; 24(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38610423

RESUMO

Metamaterial components and antennas are based on the general understanding that an artificial structure composed of adequately designed and manufactured elementary cells or arrays has unusual resonance and propagation properties. Metamaterials exhibit equivalent values of the dielectric constant and magnetic permeability that are both negative simultaneously, in contrast with ordinary materials. Single elements, periodic, or quasi-periodic configurations can be suitable for a metamaterial response. In this paper, equivalent circuits for microwave propagation and resonance are compared, deriving a lumped element modeling complementary to those already available in the literature, with a particular focus on planar resonating devices and calculating the effective value for the dielectric constant and the magnetic permeability directly from experimental findings using the impedance (Z-parameters) notation.

9.
Sensors (Basel) ; 24(12)2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38931523

RESUMO

Testing the shielding effectiveness of materials is a key step for many applications, from the industrial to the biomedical field. This task is very relevant for high-sensitivity sensors, whose performance can be greatly affected by electromagnetic fields. However, the available testing procedures often require expensive, bulky, and heavy measurement chambers. In this paper, a cost-effective and reliable measurement procedure for testing the shielding effectiveness of materials is proposed. It exploits a lab-scale anechoic shielded chamber, which is lightweight, compact, and cost-effective if compared to the available commercial solutions. The measurement procedure employs a vector network analyzer to allow an accurate and fast characterization setup. The chamber realization phases and the measurement procedure are described. The shielding capability of the chamber is measured up to 26 GHz, whereas the performance of commercial shielding coatings is tested to demonstrate the measurement's effectiveness.

10.
Radiol Med ; 129(8): 1252-1264, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38958915

RESUMO

PURPOSE: Microwave ablation (MWA) and conventional transarterial chemoembolization (cTACE) are locoregional treatments commonly performed in very early, early and intermediate stages of hepatocellular carcinoma (HCC). Despite combined locoregional approaches have shown encouraging results in obtaining complete tumor necrosis, their application in a single session is poorly described. Our aim was to evaluate the safety and efficacy of single-session MWA and cTACE treatment in 5-cm HCCs and its influence on liver function. MATERIALS AND METHODS: All 5-cm HCCs treated by MWA and cTACE performed in a single-session in our Interventional Radiology unit between January 2020 and December 2022 were retrospectively recorded and analyzed. Patients with poor or missing pre- and post-treatment imaging were excluded. Technical success, clinical success, and complications rate were examined as primary endpoints. Pre- and post-treatment liver function laboratory parameters were also evaluated. RESULTS: A total of 15 lesions (mean lesion diameter, 5.0 ± 1.4 cm) in 15 patients (11 men; mean age, 67.1 ± 8.9 years) were retrospectively evaluated. Technical and clinical success were 100% and 73%, respectively. Four (27%) cases of partial response and no cases of progressive or stable disease were recorded. AST and ALT values have found to be significantly higher in post-treatment laboratory tests. No other significant differences between pre- and post-treatment laboratory values were registered. AST and ALT pre- and post-treatment higher differences (ΔAST and ΔALT) were significantly associated with a lower clinical success rate. CONCLUSION: MWA and cTACE single-session approach is safe and effective for 5-cm HCCs, without significant liver function impairment. A post-treatment increase in AST and ALT values may be a predictor for clinical failure.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Micro-Ondas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/cirurgia , Masculino , Feminino , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/cirurgia , Estudos Retrospectivos , Idoso , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Quimioembolização Terapêutica/métodos , Testes de Função Hepática , Resultado do Tratamento , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
11.
J Clin Monit Comput ; 38(1): 77-88, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37792139

RESUMO

PURPOSE: Non-contact continuous respiratory rate monitoring is preferred for early detection of patient deterioration. However, this technique is under development; a gold standard respiratory monitor has not been established. Therefore, this prospective observational method comparison study aimed to compare the measurement accuracy of a non-contact continuous respiratory rate monitor, a microwave Doppler sensor positioned beneath the mattress, with that of other monitors. METHODS: The respiratory rate of intensive care unit patients was simultaneously measured using a microwave Doppler sensor, capnography, thoracic impedance pneumography, and a piezoelectric sensor beneath the mattress. Bias and 95% limits of agreement between the respiratory rate measured using capnography (standard reference) and that measured using the other three methods were calculated using Bland-Altman analysis for repeated measures. Clarke error grid (CEG) analysis evaluated the sensor's ability to assist in correct clinical decision-making. RESULTS: Eighteen participants were included, and 2,307 data points were analyzed. The bias values (95% limits of agreement) of the microwave Doppler sensor, thoracic impedance pneumography, and piezoelectric sensor were 0.2 (- 4.8 to 5.2), 1.5 (- 4.4 to 7.4), and 0.4 (- 4.0 to 4.8) breaths per minute, respectively. Clinical decisions evaluated using CEG analyses were correct 98.1% of the time for the microwave Doppler sensor, which was similar to the performance of the other devices. CONCLUSION: The microwave Doppler sensor had a small bias but relatively low precision, similar to other devices. In CEG analyses, the risk of each monitor leading to inadequate clinical decision-making was low. TRIAL REGISTRATION NUMBER: UMIN000038900, February 1, 2020.


Assuntos
Micro-Ondas , Taxa Respiratória , Humanos , Reprodutibilidade dos Testes , Monitorização Fisiológica/métodos , Capnografia/métodos
12.
Molecules ; 29(15)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39125050

RESUMO

Titanium dioxide was synthesized via hydrolysis of titanium (IV) isopropoxide using a sol-gel method, under neutral or basic conditions, and heated in the microwave-assisted solvothermal reactor and/or high-temperature furnace. The phase composition of the prepared samples was determined using the X-ray diffraction method. The specific surface area and pore volumes were determined through low-temperature nitrogen adsorption/desorption studies. The photoactivity of the samples was tested through photocatalytic reduction of carbon dioxide. The composition of the gas phase was analyzed using gas chromatography, and hydrogen, carbon oxide, and methane were identified. The influence of pH and heat treatment on the physicochemical properties of titania-based materials during photoreduction of carbon dioxide have been studied. It was found that the photocatalysts prepared in neutral environment were shown to result in a higher content of hydrogen, carbon monoxide, and methane in the gas phase compared to photocatalysts obtained under basic conditions. The highest amounts of hydrogen were detected in the processes using photocatalysts heated in the microwave reactor, and double-heated photocatalysts.

13.
Biochem Biophys Res Commun ; 661: 89-98, 2023 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-37087803

RESUMO

The ubiquity of wireless electronic-device connectivity has seen microwaves emerge as one of the fastest growing forms of electromagnetic exposure. A growing evidence-base refutes the claim that wireless technologies pose no risk to human health at current safety levels designed to limit thermal (heating) effects. The potential impact of non-thermal effects of microwave exposure, especially in electrically-excitable tissues (e.g., heart), remains controversial. We exposed human embryonic stem-cell derived cardiomyocytes (CM), under baseline and beta-adrenergic receptor (ß-AR)-stimulated conditions, to microwaves at 2.4 GHz, a frequency used extensively in wireless communication (e.g., 4G, Bluetooth™ and WiFi). To control for any effect of sample heating, experiments were done in CM subjected to matched rates of direct heating or CM maintained at 37 °C. Detailed profiling of the temporal and amplitude features of Ca2+ signalling in CM under these experimental conditions was reconciled with the extent and spatial clustering of apoptosis. The data show that exposure of CM to 2.4 GHz EMF eliminated the normal Ca2+ signalling response to ß-AR stimulation and provoked spatially-clustered apoptosis. This is first evidence that non-thermal effects of 2.4 GHz microwaves might have profound effects on human CM function, responsiveness to activation, and survival.


Assuntos
Micro-Ondas , Receptores Adrenérgicos beta , Humanos , Miócitos Cardíacos , Transdução de Sinais , Campos Eletromagnéticos
14.
Small ; 19(2): e2205341, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36399645

RESUMO

Chloramphenicol (CAP) has long been used extensively in agriculture and is severely toxic to the biological environment. Microwave catalysis appears a promising method for soil remediation due to its fast and effective heat transfer, but it is challenging to prepare catalysts with good electromagnetic wave absorption and robust catalytic activity. In this study, atomically dispersed Fe on three-dimensional N-doped carbon supports (3D Fe-NC) is firstly used for microwave remediation of soil. Thanks to the synergistic effect of microwave "hot spots" and reactive oxygen species (•OH, •O2 - ), 3D Fe-NC can completely remove 99.9% of CAP in 5 min. The removal rate constant is nearly twice that of commercial activated carbon. Significantly, the germination rate of lettuce seeds in microwave-repaired soil contaminated by CAP reaches 70%. This work demonstrates the application of Fe single-atom catalyst in microwave remediation of contaminated soil, providing a novel insight for agricultural soil remediation.


Assuntos
Cloranfenicol , Poluentes do Solo , Micro-Ondas , Solo , Catálise
15.
Small ; 19(49): e2304440, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37544921

RESUMO

Microwave (MW) dynamic therapy (MDT) can efficiently eliminate tumor residue resulting from MW thermal therapy. However, MDT is currently in its infancy, and luck of effective MDT sensiters severely limits its clinical therapeutic effect. Herein, based on TiMOF (TM), a high-efficiency MW sensitizer is designed for MW thermo-dynamic therapy. TM can generate heat and cytotoxic reacyive oxygen species (ROS) under MW irradiation and has the potential to be used as an MW sensitizer, while the suboptimal MW dynamic sensitization effect of TM limits its application. Inorder to improve the MW dynamic sensitization performance, a covalent organic framework (COF) with good stability and a large conjugate system is used to cover TM, which is conductive to electron and energy transfer, thus increasing the ROS generation rate and prolonging the ROS lifetime. In addition, loading Ni NPs endow nanomaterials with magnetic resonance imaging capabilities. Therefore, this work develops an MW sensitizer based on TM for the first time, and the mechanism of COF coating to enhance the MW dynamic sensitization of TM is preliminarily explored, which provides a new idea for the further development of MW sensitizer with great potential.


Assuntos
Estruturas Metalorgânicas , Nanoestruturas , Neoplasias , Humanos , Estruturas Metalorgânicas/química , Micro-Ondas , Espécies Reativas de Oxigênio , Neoplasias/tratamento farmacológico
16.
J Urol ; 209(1): 81-88, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36440817

RESUMO

PURPOSE: Guidelines suggest less favorable cancer control outcomes for local tumor destruction in T1a renal cell carcinoma patients with tumor size 3.1-4 cm. We compared cancer-specific mortality between cryoablation vs heat-based thermal ablation in patients with tumor size 3.1-4 cm, as well as in patients with tumor size ≤3 cm. MATERIALS AND METHODS: Within the Surveillance, Epidemiology, and End Results database (2004-2018), we identified patients with clinical T1a stage renal cell carcinoma treated with cryoablation or heat-based thermal ablation. After up to 2:1 ratio propensity score matching between patients treated with cryoablation vs heat-based thermal ablation, we addressed cancer-specific mortality relying on competing risks regression models, adjusted for other-cause mortality and other covariates (age, tumor size, tumor grade, and histological subtype). RESULTS: Of 1,468 assessable patients with tumor size 3.1-4 cm, 1,080 vs 388 were treated with cryoablation vs heat-based thermal ablation, respectively. After up to 2:1 propensity score matching that resulted in 757 cryoablations vs 388 heat-based thermal ablations, in multivariable competing risks regression models, heat-based thermal ablation was associated with higher cancer-specific mortality (HR:2.02, P < .001), relative to cryoablation. Of 4,468 assessable patients with tumor size ≤3 cm, 3,354 vs 1,114 were treated with cryoablation vs heat-based thermal ablation, respectively. After up to 2:1 propensity score matching that resulted in 2,217 cryoablations vs 1,114 heat-based thermal ablations, in multivariable competing risks regression models, heat-based thermal ablation was not associated with higher cancer-specific mortality (HR:1.13, P = .5) relative to cryoablation. CONCLUSIONS: Our findings corroborated that in cT1a patients with tumor size 3.1-4 cm, cancer-specific mortality is twofold higher after heat-based thermal ablation vs cryoablation. Conversely, in patients with tumor size ≤3 cm either ablation technique is equally valid. These findings should be considered at clinical decision making and informed consent.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Carcinoma de Células Renais/cirurgia , Temperatura Alta , Neoplasias Renais/cirurgia
17.
Eur Radiol ; 33(3): 1938-1948, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36114849

RESUMO

OBJECTIVES: The therapeutic efficacy of microwave ablation (MWA) for subcapsular hepatocellular carcinoma (HCC) has not been well characterized. We aimed to compare the long-term outcomes of MWA and surgical resection (SR) in patients with subcapsular HCC. METHODS: This retrospective study comprised 321 patients with subcapsular HCC meeting the Milan criteria who received MWA (n = 99) or SR (n = 222). Local tumor progression (LTP), overall survival (OS), and disease-free survival (DFS) were analyzed using propensity score matching (PSM) to compare the therapeutic efficacy. RESULTS: In the total cohort, there were no significant differences in 5-year LTP rates (14.0% vs. 8.9%, p = 0.12), OS rates (70.7% vs. 73.2%, p = 0.63), and DFS rates (38.3% vs. 41.2%, p = 0.22) between the MWA and SR groups. After PSM, the cumulative LTP rates at 1, 3, and 5 years were 9.7%, 14.0%, and 16.4% in the MWA group (n = 84) and 7.2%, 8.6%, and 10.6% in the SR group (n = 84), respectively, with no significant difference (p = 0.31). Neither corresponding OS rates (96.4%, 84.8%, and 73.0% vs. 95.2%, 85.5%, and 72.1%, p = 0.89) nor DFS rates (76.0%, 52.6%, and 38.1% vs. 76.2%, 44.7%, and 32.3%, p = 0.43) were significantly different between the MWA and SR groups. Whereas MWA obtained fewer complications for both cohorts (both p < 0.05). CONCLUSION: MWA showed comparable long-term therapeutic outcomes to SR, and it might be an alternative curative option for subcapsular HCC within the Milan criteria. KEY POINTS: • Microwave ablation showed comparable local tumor progression, overall survival, and disease-free survival to surgical resection for subcapsular hepatocellular carcinoma meeting the Milan criteria. • Microwave ablation obtained fewer complications and shorter postoperative hospital stay.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Micro-Ondas/uso terapêutico , Pontuação de Propensão , Estudos Retrospectivos , Resultado do Tratamento
18.
Eur Radiol ; 33(4): 2407-2414, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36472698

RESUMO

OBJECTIVES: To investigate the value of contrast-enhanced ultrasound (CEUS) combined with feeding artery ablation in the microwave ablation (MWA) of large solid benign thyroid nodules (LSBTNs) with a diameter ≥ 4 cm. METHODS: We retrospectively analyzed 122 patients with LSBTN ≥ 4 cm in diameter treated with MWA. During evaluations before and after MWA, 53 patients who underwent conventional ultrasound examination were classified as the routine group, and 69 patients who underwent CEUS combined with feeding artery ablation were classified as the union group. The differences in ablation energy required per milliliter (AERPM), complication rate, regrowth rate, and volume reduction rate (VRR) were compared between the two groups. RESULTS: The AERPM of the union group was significantly less than that of the routine group (956.3 ± 38.5 J/mL vs. 1025.9 ± 121.5 J/mL, p < 0.001). The complication rate of the routine group was significantly higher than that of the union group (13.2% vs. 2.9%, p = 0.031). The regrowth rate of the routine group (22.6%, 12/53) was significantly higher than that of the union group (7.2%, 5/69) (p = 0.015). At the 1st, 3rd, 6th, 12th, 18th, and 24th month after ablation, the mean VRRs of the routine group were significantly less than those of the union group, with p values of < 0.001, < 0.001, 0.002, 0.007, 0.013, and < 0.001, respectively. CONCLUSIONS: The application of CEUS combined with feeding artery ablation in the MWA of LSBTNs is helpful to reduce the regrowth rate, improve the ablation efficiency, and reduce bleeding. KEY POINTS: • CEUS combined with feeding artery ablation in MWA of LSBTNs is helpful to reduce regrowth rate. • CEUS combined with feeding artery ablation can help improve ablation efficiency than conventional ultrasound in LSBTNs. • CEUS combined with feeding artery ablation helps reduce the incidence of bleeding during MWA.


Assuntos
Ablação por Cateter , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/cirurgia , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Artérias
19.
Eur Radiol ; 33(2): 1050-1062, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36048208

RESUMO

OBJECTIVE: To compare the acute and chronic safety and treatment effects of non-invasive hepatic histotripsy vs. percutaneous microwave (MW) ablation in a healthy porcine model. METHODS: This was a dual-arm study in which each animal (n = 14) received either a single hepatic microwave (n = 6) or histotripsy (n = 6 single treatment; n = 2 double treatment) under ultrasound guidance. The goal was to create 2.5-3.0 cm short-axis treatments in similar locations across modalities. Animals were survived for 1 month with contrast-enhanced CT imaging on days 0, 2, 7, 14, and 28. On day 28, necropsy and histopathology were performed. RESULTS: All procedures were well-tolerated. MW ablation zones were longer and more oblong, but equivalent in the short axes to histotripsy zones on immediate post-procedure CT (p < 0.001 and p = 0.45, respectively). Overall, MW volumes were larger (21.4 cm3 vs. 13.4 cm3; p = 0.001) and histotripsy treatment zones were more spherical (p = 0.007). Histotripsy zones were close to the prescribed size (p < 0.001). Over the study period, histotripsy treatment zones decreased in volume while microwave ablation zones slightly increased (-83% vs. +17%, p = 0.001). There were several imaging-only findings: Branch portal vein thrombus with both histotripsy (7/8) and MW (6/6), hematoma in 2/6 MW only, and a gallbladder injury in 1/6 MW animals. The ablation zones demonstrated complete cellular destruction for both modalities. CONCLUSION: Histotripsy was associated with more spherical treatments, fewer biliary complications, and greater treatment zone involution. Hepatic MW and histotripsy treatment in a normal porcine model appear at least equally effective for creating treatment zones with a similar safety profile. KEY POINTS: • Microwave ablation and histotripsy for liver treatment in a healthy porcine model yield equivalent procedural tolerance and cellular destruction. • Histotripsy was associated with more spherical treatments, fewer biliary complications, and greater treatment zone involution over the 28-day follow-up period. • These findings confirm the safety and efficacy of hepatic histotripsy and support the pursuit of clinical trials to further evaluate the translatability of these results.


Assuntos
Técnicas de Ablação , Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Micro-Ondas/uso terapêutico , Fígado/diagnóstico por imagem , Fígado/cirurgia , Fígado/irrigação sanguínea , Técnicas de Ablação/métodos , Veia Porta/cirurgia , Ablação por Cateter/métodos
20.
Eur Radiol ; 33(8): 5740-5751, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36892641

RESUMO

OBJECTIVES: To compare the incidence of persistent air leak (PAL) following cryoablation vs MWA of lung tumors when the ablation zone includes the pleura. METHODS: This bi-institutional retrospective cohort study evaluated consecutive peripheral lung tumors treated with cryoablation or MWA from 2006 to 2021. PAL was defined as an air leak for more than 24 h after chest tube placement or an enlarging postprocedural pneumothorax requiring chest tube placement. The pleural area included by the ablation zone was quantified on CT using semi-automated segmentation. PAL incidence was compared between ablation modalities and a parsimonious multivariable model was developed to assess the odds of PAL using generalized estimating equations and purposeful selection of predefined covariates. Time-to-local tumor progression (LTP) was compared between ablation modalities using Fine-Gray models, with death as a competing risk. RESULTS: In total, 260 tumors (mean diameter, 13.1 mm ± 7.4; mean distance to pleura, 3.6 mm ± 5.2) in 116 patients (mean age, 61.1 years ± 15.3; 60 women) and 173 sessions (112 cryoablations, 61 MWA) were included. PAL occurred after 25/173 (15%) sessions. The incidence was significantly lower following cryoablation compared to MWA (10 [9%] vs 15 [25%]; p = .006). The odds of PAL adjusted for the number of treated tumors per session were 67% lower following cryoablation (odds ratio = 0.33 [95% CI, 0.14-0.82]; p = .02) vs MWA. There was no significant difference in time-to-LTP between ablation modalities (p = .36). CONCLUSIONS: Cryoablation of peripheral lung tumors bears a lower risk of PAL compared to MWA when the ablation zone includes the pleura, without adversely affecting time-to-LTP. KEY POINTS: • The incidence of persistent air leaks after percutaneous ablation of peripheral lung tumors was lower following cryoablation compared to microwave ablation (9% vs 25%; p = .006). • The mean chest tube dwell time was 54% shorter following cryoablation compared to MWA (p = .04). • Local tumor progression did not differ between lung tumors treated with percutaneous cryoablation compared to microwave ablation (p = .36).


Assuntos
Ablação por Cateter , Criocirurgia , Neoplasias Pulmonares , Ablação por Radiofrequência , Humanos , Feminino , Pessoa de Meia-Idade , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/patologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa