Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Biomed Chromatogr ; 38(7): e5878, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38600630

RESUMO

A simple and a sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of gedatolisib in mouse plasma. The extraction technique involved a simple precipitation method to extract gedatolisib and idelalisib (internal standard) from mouse plasma. A clean chromatographic separation of gedatolisib and the internal standard was achieved on an Atlantis dC18 column using an isocratic mobile phase (10 mm ammonium formate and acetonitrile; 30:70% v/v, both supplemented with 0.1% formic acid) delivered at a flow rate of 0.7 ml/min. The total run time was 2.0 min, and gedatolisib and idelalisib were eluted at 0.80 and 0.95 min, respectively. Gedatolisib was monitored at m/z 616.40 → 488.20 and idelalisib at 416.05 → 176.10. All the required parameters for the method validation were performed as per US Food and Drug Administration guidelines, and the results were within the acceptance criteria. The method was accurate and proved to be precise at a linearity range of 1.33-2667 ng/ml. The accuracy for gedatolisib in mouse plasma was in the ranges 0.99-1.06% (intra-day) and 0.96-1.04% (inter-day). Gedatolisib appeared to be stable in a series of stability conditions. Gedatolisib showed a good intravenous profile when administered through a solution formulation.


Assuntos
Espectrometria de Massas em Tandem , Animais , Espectrometria de Massas em Tandem/métodos , Camundongos , Reprodutibilidade dos Testes , Modelos Lineares , Masculino , Cromatografia Líquida/métodos , Limite de Detecção , Estabilidade de Medicamentos , Quinazolinonas/sangue , Quinazolinonas/farmacocinética , Quinazolinonas/química , Sensibilidade e Especificidade
2.
Biomed Chromatogr ; 37(4): e5587, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36680551

RESUMO

Paxalisib is a pan-PI3K and mTOR inhibitor, currently entering into Phase II clinical trials as a potential drug to treat glioblastoma patients. We report the development and validation of a high-performance liquid chromatography (HPLC) method for the quantitation of paxalisib in mouse plasma as per the US Food and Drug Administration regulatory guidelines. From the mouse plasma, paxalisib and the internal standard (IS; filgotinib) were extracted using ethyl acetate as an extraction solvent. The chromatographic separation of paxalisib and the IS was accomplished on a Symmetry C18 (250 × 4.6 mm, 5.0 µm) column maintained at 40°C using 10 mm ammonium formate and acetonitrile in gradient conditions at a 0.8 ml/min flow-rate. The injection volume was 20 µl. The elution was monitored using a photo-diode array detector set at λmax 280 nm. Paxalisib and the IS eluted at 6.5 and 5.9 min, respectively with a total run time of 10 min. The calibration curve was linear over the range of 111-4,989 ng/ml. Inter- and intraday precision and accuracy, stability studies, dilution integrity and incurred sample reanalysis were investigated and the results met the acceptance criteria. The validated HPLC method was extended to assess the pharmacokinetic parameters of paxalisib in mice.


Assuntos
Fosfatidilinositol 3-Quinases , Inibidores de Proteínas Quinases , Camundongos , Animais , Cromatografia Líquida de Alta Pressão/métodos , Reprodutibilidade dos Testes , Inibidores de Proteínas Quinases/farmacocinética , Inibidores de MTOR , Serina-Treonina Quinases TOR
3.
Biomed Chromatogr ; 37(8): e5650, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37070164

RESUMO

A sensitive and rapid LC-MS/MS method has been developed and validated for the quantification of paxalisib in mouse plasma. A liquid-liquid extraction method was used for the extraction of paxalisib and filgotinib (internal standard, IS) from mouse plasma. A clean chromatographic separation of paxalisib and the IS was achieved on an Atlantis dC18 column using an isocratic mobile phase (10 mM ammonium formate and acetonitrile, 30:70%, v/v) delivered at a flow rate of 0.7 mL/min. The total run time was 2.5 min. Paxalisib and filgotinib were eluted at 1.21 and 0.94 min, respectively. The MS/MS transitions monitored were m/z 383.25 → 309.20 and 426.30 → 291.20 for paxalisib and filgotinib, respectively. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The method was proved to be accurate and precise at a linearity range of 1.39-2287 ng/mL. The intra- and inter-day precisions for paxalisib in mouse plasma were in the ranges 1.42-9.61 and 4.70-9.63%, respectively. Paxalisib was stable under a series of stability conditions. Post-oral administration to mice, paxalisib maximum plasma concentrations were attained at 2.0 h. Paxalisib's half-life ranged between 3.2 and 4.2 h. Paxalisib exhibited low clearance and moderate volume of distribution. Oral bioavailability was 71%.


Assuntos
Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Camundongos , Animais , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Modelos Lineares , Inibidores de Proteínas Quinases
4.
J Proteome Res ; 21(3): 691-701, 2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-34968064

RESUMO

Reversed-phase UHPLC-MS is extensively employed for both the profiling of biological fluids and tissues to characterize lipid dysregulation in disease and toxicological studies. With conventional LC-MS systems the chromatographic performance and throughput are limited due to dispersion from the fluidic connections as well as radial and longitudinal thermal gradients in the LC column. In this study vacuum jacketed columns (VJC), positioned at the source of the mass spectrometer, were applied to the lipidomic analysis of plasma extracts. Compared to conventional UHPLC, the VJC-based methods offered greater resolution, faster analysis, and improved peak intensity. For a 5 min VJC analysis, the peak capacity increased by 66%, peak tailing reduced by up to 34%, and the number of lipids detected increased by 30% compared to conventional UHPLC. The narrower peaks, and thus increased resolution, compared to the conventional system resulted in a 2-fold increase in peak intensity as well a significant improvement in MS and MS/MS spectral quality resulting in a 22% increase in the number of lipids identified. When applied to mouse plasma samples, reproducibility of the lipid intensities in the pooled QC ranged from 1.8-12%, with no related drift in tR observed.


Assuntos
Lipidômica , Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida de Alta Pressão/métodos , Lipídeos , Camundongos , Reprodutibilidade dos Testes , Vácuo
5.
BMC Vet Res ; 18(1): 145, 2022 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-35443692

RESUMO

BACKGROUND: UK-5099 is a potent mitochondrial acetone carrier inhibitor, that exhibits anticancer activity. Recently, the anti-Toxoplasma gondii activity of UK-5099 was proposed, and in vivo studies of its pharmacokinetics in BALB/c mice are necessary to further evaluate the clinical effect of UK-5099. METHODS AND RESULTS: A simple and fast high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) analysis method was established and verified in terms of its linearity, matrix effect, accuracy, precision, recovery and stability. The analytes were separated by an Agilent ZORBAX XDB-C18 column (2.1 × 50 mm, 3.5 µm) at 30 °C. A gradient mobile phase consisting of water with 0.1% formic acid (FA) (phase A) and acetonitrile (ACN) (phase B) was delivered at a flow rate of 0.40 mL·min-1 with an injection volume of 5 µL. A good linear response was obtained in a concentration range of 5-5000 ng·mL-1 (r2 = 0.9947). The lower limit of quantification (LLOQ) was 5 ng·mL-1. The extraction recovery of UK-5099 was greater than 95%. The inter- and intra-day accuracy and precision of the method showed relative standard deviations (RSDs) of less than 15%. This method has been successfully applied to the pharmacokinetic evaluation of UK-5099 in mouse plasma. In health mice, the main pharmacokinetic parameters of UK-5099 after intraperitoneal administration were measured using a noncompartmental model, in which the AUC0-t was 42,103 ± 12,072 ng·h·mL-1 and the MRT0-t was 0.857 ± 0.143 h. The peak concentration (Cmax) was 82,500 ± 20,745 ng·h·mL-1, which occurred at a peak time (Tmax) = 0.250 ± 0.000 h. CONCLUSIONS: A fast and sensitive HPLC-MS/MS method was developed, validated and successfully used for the determination of UK-5099 levels in mice after intraperitoneal administration. This study was the first report of the pharmacokinetic parameters of UK-5099 in mice, which will help to further study the administration of UK-5099 in animals and humans.


Assuntos
Acrilatos , Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/veterinária , Cromatografia Líquida/veterinária , Camundongos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/veterinária
6.
J Appl Toxicol ; 42(9): 1477-1490, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35199358

RESUMO

Cardiotoxicity is a serious adverse effect of an anticancer drug, doxorubicin (DOX), which can occur within a year or decades after completion of therapy. The present study was designed to address a knowledge gap concerning a lack of circulating biomarkers capable of predicting the risk of cardiotoxicity induced by DOX. Profiling of 2083 microRNAs (miRNAs) in mouse plasma revealed 81 differentially expressed miRNAs 1 week after 6, 9, 12, 18, or 24 mg/kg total cumulative DOX doses (early-onset model) or saline (SAL). Among these, the expression of seven miRNAs was altered prior to the onset of myocardial injury at 12 mg/kg and higher cumulative doses. The expression of only miR-34a-5p was significantly (false discovery rate [FDR] < 0.1) elevated at all total cumulative doses compared with concurrent SAL-treated controls and showed a statistically significant dose-related response. The trend in plasma miR-34a-5p expression levels during DOX exposures also correlated with a significant dose-related increase in cardiac expression of miR-34a-5p in these mice. Administration of a cardioprotective drug, dexrazoxane, to mice before DOX treatment, significantly mitigated miR-34a-5p expression in both plasma and heart in conjunction with attenuation of cardiac pathology. This association between plasma and heart may suggest miR-34a-5p as a potential early circulating marker of early-onset DOX cardiotoxicity. In addition, higher expression of miR-34a-5p (FDR < 0.1) in plasma and heart compared with SAL-treated controls 24 weeks after 24 mg/kg total cumulative DOX dose, when cardiac function was altered in our recently established delayed-onset cardiotoxicity model, indicated its potential as an early biomarker of delayed-onset cardiotoxicity.


Assuntos
Cardiotoxicidade , MicroRNAs , Animais , Biomarcadores , Doxorrubicina/toxicidade , Coração , Camundongos , MicroRNAs/metabolismo
7.
Biomed Chromatogr ; 36(8): e5387, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35470912

RESUMO

In this study, we report the development and validation of an LC-tandem mass spectrometry method for the simultaneous quantitation of bendamustine and copanlisib in mouse plasma as per the US FDA regulatory guidelines. The sample processing involves extraction of bendamustine and copanlisib along with internal standard (IS; warfarin) from 50 µL mouse plasma using a liquid-liquid extraction method. The chromatographic separation of bendamustine, copanlisib and the IS was achieved on an Atlantis dC18 column using an isocratic mobile phase (5 mM ammonium acetate:methanol, 20:80 v/v). Bendamustine, copanlisib and the IS eluted at 0.88, 1.39 and 0.74 min, respectively, with a total run time of 2.5 min. The calibration curve ranged from 3.99-2996 and 4.33-3248 ng/mL for bendamustine and copanlisib, respectively. Inter- and intra-day precision and accuracy, stability in processed samples and upon storage, dilution integrity and incurred sample reanalysis were investigated for both the analytes. The intra- and inter-day precisions were in the ranges of 2.01%-5.05% and 2.74%-6.13% and 1.98%-7.64 and 8.62%-9.04% for bendamustine and copanlisib, respectively. Stability studies showed that both analytes were stable on bench top for 6 h, in auto-sampler for 24 and at -80°C for 30 days. The validated method was successfully applied to a pharmacokinetic study in mice.


Assuntos
Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Animais , Cloridrato de Bendamustina , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Camundongos , Pirimidinas , Quinazolinas , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos
8.
Biomed Chromatogr ; 35(4): e5043, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33283304

RESUMO

AMG 510 is the first-in-class KRASG12C inhibitor, currently in phase 2 clinical trials as an orphan drug to treat non-small cell lung cancer patients. We developed and validated a sensitive, selective, and high-throughput HPLC-MS/MS method for the quantitation of AMG 510 in mouse plasma per the regulatory guideline of the US Food and Drug and Administration. AMG 510 and the IS (MRTX-1257) were extracted from mouse plasma using tert-butyl methyl ether and chromatographed using an isocratic mobile phase (0.2% formic acid:acetonitrile; 25:75, v/v) at a flow rate of 0.65 mL/min on an Atlantis dC18 column. AMG 510 and the IS eluted at ~0.95 and 0.73 min, respectively. AMG 510 and the IS were detected by positive electrospray ionization in multiple reaction monitoring using transition pair (Q1 → Q3) m/z 561.1 → 134.1 and m/z 566.5 → 98.2, respectively. Excellent linearity was achieved in the concentration range of 1.08-5040 ng/mL (r > 0.0996). No matrix effect and carryover were observed. Intra- and inter-day accuracies and precisions were within the acceptance range. AMG 510 was demonstrated to be stable under the tested storage conditions. This novel method has been applied to a pharmacokinetic study in mice.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Piperazinas/sangue , Piperazinas/farmacocinética , Piridinas/sangue , Piridinas/farmacocinética , Pirimidinas/sangue , Pirimidinas/farmacocinética , Espectrometria de Massas em Tandem/métodos , Animais , Modelos Lineares , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Piperazinas/química , Proteínas Proto-Oncogênicas p21(ras)/antagonistas & inibidores , Piridinas/química , Pirimidinas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Anal Biochem ; 591: 113555, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31874172

RESUMO

A cycloalkyl-based polymer monolithic column for solid-phase extraction was prepared via radical polymerization using cyclohexyl methacrylate as the monomer. The preparative conditions such as crosslinker/monomer ratio and the amount of the porogens were optimized and the resulting monoliths were characterized by scanning electron microscopy and nitrogen adsorption-desorption method. On-line solid-phase extraction-high-performance liquid chromatography was performed to quantitatively analyse polyphyllin I, II, VI and VII contained in herbal medicine of paridis rhizome in mouse plasma using the homemade optimized monolithic SPE column combined with a C18 column, in which water was used to remove the plasma matrix while the polyphyllins in the mouse plasma were eluted by acetonitrile-water (42:58, V/V). Results obtained from the method validation show that the present method is feasible for the quantitative analysis of the four polyphyllins in plasma. The developed method was further applied for the real mouse plasma sample. These results show that the homemade cycloalkyl-based polymer monolithic SPE column has good ability for clean-up of the interfering bio-matrix and simultaneously extracting the four polyphyllins from mouse plasma. Furthermore, the present method is a promising method for quantitative determination of saponins compounds from complex bio-samples with the advantages of simple and efficient.


Assuntos
Saponinas/sangue , Extração em Fase Sólida/métodos , Animais , Cicloparafinas/química , Diosgenina/análogos & derivados , Camundongos , Polímeros/química , Esteroides
10.
Biomed Chromatogr ; 34(2): e4752, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31756277

RESUMO

A sensitive analytical method was developed and validated for the quantification of cotinine in mouse plasma after exposure to smoke of 0.5, 1.0, and 1.5 commercially available cigarettes, using liquid chromatography tandem mass spectrometry. The method was validated over a linear concentration range of 0.075-20.0 ng/mL with the R2 value being higher than 0.99. Both the precision (coefficient of variation; %) and accuracy (relative error; %) were within acceptable criteria of <15%. The lower limit of quantification (LLOQ) for cotinine was 0.075 ng/mL with sufficient specificity, accuracy, and precision. Following exposure to 0.5, 1.0, and 1.5 cigarette smoke, it was observed that the AUC and the Cmax increased linearly as the doses increased. The pharmacokinetics of cotinine was found linear for the range of 0.5-1.5 commercial cigarette smoke. The quantification of the concentration of cotinine in mouse plasma after smoke exposure will facilitate future behavioral and toxicological experiments in animals and may prove useful in predicting cotinine levels in humans during smoking.


Assuntos
Cotinina/sangue , Cotinina/farmacocinética , Exposição por Inalação/análise , Poluição por Fumaça de Tabaco , Animais , Cotinina/química , Modelos Lineares , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Molecules ; 25(5)2020 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-32164308

RESUMO

Doxorubicin, an anthracycline antitumor antibiotic, acts as a cancer treatment by interfering with the function of DNA. Herein, liquid chromatography-tandem mass spectrometry was for the first time developed and validated for the simultaneous determination of doxorubicin and its major metabolites doxorubicinol, doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone in mouse plasma. The liquid-liquid extraction of a 10 µL mouse plasma sample with chloroform:methanol (4:1, v/v) and use of the selected reaction monitoring mode led to less matrix effect and better sensitivity. The lower limits of quantification levels were 0.5 ng/mL for doxorubicin, 0.1 ng/mL for doxorubicinol, and 0.01 ng/mL for doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone. The standard curves were linear over the range of 0.5-200 ng/mL for doxorubicin; 0.1-200 ng/mL for doxorubicinol; and 0.01-50 ng/mL for doxorubicinone, doxorubicinolone, and 7-deoxydoxorubicinone in mouse plasma. The intra and inter-day relative standard deviation and relative errors for doxorubicin and its four metabolites at four quality control concentrations were 0.9-13.6% and -13.0% to 14.9%, respectively. This method was successfully applied to the pharmacokinetic study of doxorubicin and its metabolites after intravenous administration of doxorubicin at a dose of 1.3 mg/kg to female BALB/c nude mice.


Assuntos
Doxorrubicina/análogos & derivados , Doxorrubicina/sangue , Doxorrubicina/metabolismo , Naftacenos/sangue , Plasma/metabolismo , Animais , Antibióticos Antineoplásicos/sangue , Antibióticos Antineoplásicos/metabolismo , Cromatografia Líquida/métodos , Feminino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Espectrometria de Massas em Tandem/métodos
12.
Molecules ; 25(18)2020 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-32911847

RESUMO

An accurate and simple HPLC-UV method has been developed for the determination of clonidine in mouse plasma. A reversed phase C18 Nova Pack® column (125 mm × 4.6 mm i.d., × 3 µm particle size) was used as stationary phase. The mobile phase composition was a mixture of 0.1% diethylamine/acetonitrile (70:30, v/v) at pH 8 in an isocratic mode at flow rate was 1.0 mL/min. Detection was set at 210 nm. Tizanidine was used as an internal standard. The clonidine and tizanidine were extracted from plasma matrix using the deproteinization technique. The developed method exhibited a linear calibration range 100.0-2000 ng/mL and the lower limit of detection (LOD) and quantification (LOQ) were 31.0 and 91.9 ng/mL, respectively. The intra-day and inter-day accuracy and precision of the method were within 8.0% and 3.0%, respectively, relative to the nominal concentration. The developed method was validated with respect to linearity, accuracy, precision, and selectivity according to the US Food and drug guideline. Minimal degradation was demonstrated during the determination of clonidine under different stability conditions. The suggested method has been successfully applied during a pharmacokinetic study of clonidine in mouse plasma.


Assuntos
Anti-Hipertensivos/farmacocinética , Cromatografia Líquida de Alta Pressão , Clonidina/farmacocinética , Espectroscopia Fotoeletrônica , Animais , Anti-Hipertensivos/administração & dosagem , Clonidina/administração & dosagem , Cromatografia Gasosa-Espectrometria de Massas , Camundongos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Toxicol Appl Pharmacol ; 363: 164-173, 2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30517846

RESUMO

Cardiotoxicity is a serious adverse effect of doxorubicin (DOX) treatment in cancer patients. Currently, there is a lack of sensitive biomarkers to predict the risk of DOX-induced cardiotoxicity. Using SOMAmer-based proteomic technology, 1129 proteins were profiled to identify potential early biomarkers of cardiotoxicity in plasma from male B6C3F1 mice given a weekly intravenous dose of 3 mg/kg DOX or saline (SAL) for 2, 3, 4, 6, or 8 weeks (6, 9, 12, 18, or 24 mg/kg cumulative DOX doses, respectively). Also, a group of mice received the cardio-protectant, dexrazoxane (DXZ; 60 mg/kg; intraperitoneal) 30 min before a weekly DOX or SAL dose. Proteomic analysis in plasma collected a week after the last dose showed a significant ≥1.2-fold change in level of 18 proteins in DOX-treated mice compared to SAL-treated counterparts during 8-week exposure. Of these, neurogenic locus notch homolog protein 1 (NOTCH1), von Willebrand factor (vWF), mitochondrial glutamate carrier 2, Wnt inhibitory factor 1, legumain, and mannan-binding lectin serine protease 1 were increased in plasma at 6 mg/kg cumulative DOX dose, prior to the release of myocardial injury marker, cardiac troponin I at 12 mg/kg and higher cumulative doses. These six proteins also remained significantly elevated following myocardial injury or pathology at 24 mg/kg. Pretreatment of mice with DXZ significantly attenuated DOX-induced elevated levels of only NOTCH1 and vWF with mitigation of cardiotoxicity. This suggests NOTCH1 and vWF as candidate early biomarkers of DOX cardiotoxicity, which may help in addressing a clinically important question of identifying cancer patients at risk for cardiotoxicity.


Assuntos
Antibióticos Antineoplásicos/toxicidade , Cardiotoxicidade/sangue , Doxorrubicina/toxicidade , Administração Intravenosa , Animais , Biomarcadores/sangue , Cardiotoxicidade/etiologia , Cardiotoxicidade/prevenção & controle , Dexrazoxano/administração & dosagem , Doxorrubicina/administração & dosagem , Coração/efeitos dos fármacos , Masculino , Camundongos , Miocárdio/patologia , Substâncias Protetoras/administração & dosagem , Proteoma/análise , Proteoma/efeitos dos fármacos , Proteômica , Receptor Notch1/sangue , Medição de Risco/métodos , Fator de von Willebrand/análise
14.
Anal Biochem ; 564-565: 72-79, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30339813

RESUMO

PCK3145 is an anti-metastatic synthetic peptide against prostate cancer. The objective of the study is to develop and validate novel and sensitive methods for the determination of PCK3145 and Pegylated PCK3145 in mouse plasma. An LC-MS/MS method was developed and validated for the determination of PCK3145 giving high sensitivity and linearity in the range of 0.125-4.0 µg/mL. PCK3145 characterised by short half-life, therefore, it was conjugated with the poly ethylene glycol (PEG). However, LC-MS/MS has been more difficult to apply for the quantitative analysis of PEGylated peptides due to the large size. A UHPLC-UV method was developed and validated for the determination of PEG-PCK3145, with linearity of 0.05-2.0 mg/mL. In order to further improve the sensitivity for the detection of PEG-PCK3145, an indirect ELISA method was used. It was found that this method was capable of detecting PCK3145 through the quantification of PEG with excellent sensitivity found at 0.132 ng/mL. The in vitro proteolytic stability of PCK3145 and PEG-PCK3145 in mouse plasma and whole blood was studied by LC-MS/MS and UHPLC, respectively. The LC-MS/MS and ELISA methods can be applied for monitoring levels of PCK3145 in mouse plasma for in vivo pharmacokinetic and bioavailability animal studies.


Assuntos
Cromatografia Líquida/métodos , Fragmentos de Peptídeos/análise , Proteínas Secretadas pela Próstata/análise , Espectrometria de Massas em Tandem/métodos , Animais , Cromatografia Líquida de Alta Pressão , Ensaio de Imunoadsorção Enzimática , Masculino , Camundongos , Polietilenoglicóis/química
15.
Biomed Chromatogr ; 33(11): e4658, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31325170

RESUMO

Isocitrate dehydrogenase (IDH) inhibitors comprise a novel class of anticancer drugs, which are approved to treat acute myeloid leukemia patients having mutations on IDH1/2. We report the development and validation of a high-performance liquid chromatography (HPLC) method for the simultaneous quantitation of IDH inhibitors, namely enasidenib (EDB), ivosidenib (IDB) and vorasidenib (VDB), in mouse plasma as per the US Food and Drug Administration regulatory guidelines. The method involves extraction of EDB, IDB and VDB along with internal standard (IS; phenacetin) from mouse plasma (100 µl) using a simple protein precipitation process. The chromatographic analysis was performed on an HPLC system using a gradient mobile phase (comprising 10 mm ammonium acetate and acetonitrile in a flow-gradient) and an X-Terra Phenyl column. The UV detection wave length was set at λmax 265 nm. EDB, IDB, VDB and the IS eluted at 7.36, 8.60, 9.50 and 5.12 min, respectively, with a total run time of 10 min. The calibration curve was linear over a concentration range of 0.20-12.5 µg/ml for EDB and 0.50-12.5 µg/ml for IDB and VDB (r2  = ≥0.998 for all of the analytes). Validation results met the acceptance criteria. The validated HPLC method was successfully applied to a pharmacokinetic study in mice.


Assuntos
Aminopiridinas/sangue , Antineoplásicos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Diaminas/sangue , Glicina/análogos & derivados , Isocitrato Desidrogenase/antagonistas & inibidores , Piridinas/sangue , Triazinas/sangue , Aminopiridinas/química , Aminopiridinas/farmacocinética , Animais , Antineoplásicos/química , Antineoplásicos/farmacocinética , Diaminas/química , Diaminas/farmacocinética , Estabilidade de Medicamentos , Glicina/sangue , Glicina/química , Glicina/farmacocinética , Limite de Detecção , Modelos Lineares , Masculino , Camundongos , Piridinas/química , Piridinas/farmacocinética , Reprodutibilidade dos Testes , Triazinas/química , Triazinas/farmacocinética
16.
Biomed Chromatogr ; 33(4): e4460, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30536684

RESUMO

A sensitive, selective and rapid LC-ESI-MS/MS method has been developed and validated for the quantification of copanlisib in mouse plasma using enasidenib as an internal standard (IS) as per regulatory guideline. Copanlisib and the IS were extracted from mouse plasma using ethyl acetate as an extraction solvent and chromatographed using an isocratic mobile phase (0.2% formic acid-acetonitrile; 25:75, v/v) on a HyPURITY C18 column. Copanlisib and the IS eluted at ~0.95 and 2.00 min, respectively. The MS/MS ion transitions monitored were m/z 481.1 → 360.1 and m/z 474.0 → 456.0 for copanlisib and the IS, respectively. The calibration range was 3.59-3588 ng/mL. The intra- and inter-batch accuracy and precision (RE and RSD) across quality controls met the acceptance criteria. Stability studies showed that copanlisib was stable in mouse plasma for one month. This novel method has been applied to a pharmacokinetic study in mice.


Assuntos
Cromatografia Líquida/métodos , Inibidores de Fosfoinositídeo-3 Quinase , Pirimidinas/sangue , Pirimidinas/farmacocinética , Quinazolinas/sangue , Quinazolinas/farmacocinética , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Modelos Lineares , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Pirimidinas/química , Quinazolinas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/métodos
17.
Biomed Chromatogr ; 32(5): e4173, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29315691

RESUMO

A simple, selective and reliable LC-MS/MS method was validated for simultaneous quantitation of darolutamide diastereomers in 50 µL mouse plasma using warfarin as an internal standard (IS) as per regulatory guidelines. Plasma samples were extracted by liquid-liquid extraction and the chromatographic separation was achieved on a Chiralpak IA column with an isocratic mobile phase 5 mm ammonium acetate-absolute alcohol (20:80, v/v) at a flow rate of 1.0 mL/min. Detection and quantitation was done in multiple reaction monitoring mode following the transitions m/z 397 → 202 and 307 → 250 for darolutamide diastereomers and the IS, respectively, in the negative ionization mode. The linearity range was 100-2400 ng/mL for each diastereomer. The intra- and inter-day precisions were in the ranges of 1.78-4.20 and 4.34-14.6, and 3.63-4.74 and 4.78-5.15 for diastereomer-1 and diastereomer-2, respectively. Both diastereomers were found to be stable under different stability conditions. The validated method was applied to a pharmacokinetic study in mice. Following oral administration of darolutamide at 10 mg/kg, maximum concentration in plasma was 4189 and 726 ng/mL for diastereomer-1 and diastereomer-2, respectively. The terminal half-life was found to be ~0.50 h for both the diastereomers. The AUC(0-t) was found to be 18,961 ng*h/mL for diastereomer-1 and 1340 ng*h/mL diastereomer-2.


Assuntos
Cromatografia Líquida/métodos , Pirazóis , Espectrometria de Massas em Tandem/métodos , Animais , Modelos Lineares , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Pirazóis/sangue , Pirazóis/química , Pirazóis/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos , Estereoisomerismo
18.
BMC Neurosci ; 18(1): 71, 2017 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-29020944

RESUMO

BACKGROUND: A sensitive, rapid and selective UHPLC-MS/MS method has been developed and validated for the quantification of Nicotine (NT) and Cotinine (CN) using Continine-d 3 as internal standard (IS) as per FDA guidelines. Sample preparation involved simple protein precipitation of 20 µL mouse plasma or brain homogenate using acetonitrile at 1:8 ratio. Mass Spectrometer was operated in positive polarity under the multiple reaction-monitoring mode using electro spray ionization technique and the transitions of m/z 163.2 â†’ 132.1, 177.2 â†’ 98.0 and 180.2 â†’ 101.2 were used to measure the NT, CN and IS, respectively. The elution of NT, CN and IS are at 1.89, 1.77 and 1.76 min, respectively. This was achieved with a gradient mobile phase consisting of 5 mM ammonium bicarbonate, acetonitrile and methanol (3:1, v/v) at a flow rate of 0.3 mL/min on a Kinetex EVO C18 column. The method was validated with a lower limit of quantitation 3.0 ng/mL in mouse plasma and brain for both the analytes. RESULTS: A linear response function was established for the range of concentrations 3-200 (r > 0.995) for NT and 3-600 ng/mL (r > 0.995) for CN. The intra- and inter-day precision values met the acceptance criteria. NT and CN are stable in the battery of stability studies viz., stock solution, bench-top and auto-sampler. CONCLUSION: This method was successfully utilized to validate a newly developed preclinical smoking model in mice.


Assuntos
Cotinina , Nicotina , Fumar , Espectrometria de Massas em Tandem , Animais , Encéfalo/enzimologia , Encéfalo/metabolismo , Cromatografia Líquida de Alta Pressão/métodos , Cotinina/sangue , Cotinina/líquido cefalorraquidiano , Camundongos , Nicotina/sangue , Nicotina/líquido cefalorraquidiano , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fumar/fisiopatologia , Espectrometria de Massas em Tandem/métodos
19.
Biomed Chromatogr ; 31(11)2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28493402

RESUMO

The aim of the present study was to develop a simple, sensitive and accurate liquid chromatography-electrospray ionization tandem mass spectrometry (ESI-MS/MS) method for the determination of lixivaptan (LIX) in mouse plasma using vildagliptin as the internal standard (IS). A precipitation procedure was used for the extraction of LIX and vildagliptin from mouse plasma. Chromatographic separation of LIX was achieved using a C18 analytical column (50 × 2.1 mm, 1.8 µm) at 25°C. The mobile phase comprised acetonitrile and ammonium formate (10 mm, pH 3.1; 40:60, v/v) pumped at a flow rate of 0.3 mL min-1 . A tandem mass spectrometer with an electrospray ionization source was used to perform the assay. Quantification of LIX at m/z 290 → 137 and IS at 154 → 97 was attained through multiple reaction monitoring. The investigated method was authenticated following the bio-analytical method of validation guidelines of the US Food and Drug Administration. The developed method showed a good linearity over the concentration range from 5 to 500 ng mL-1 , and the calibration curve was linear (r = 0.9998). The mean recovery of LIX from mouse plasma was 99.2 ± 0.68%. All validation parameters for LIX were within the levels required for acceptance. The proposed method was effectively used for a pharmacokinetic study of LIX in mouse plasma.


Assuntos
Benzamidas/sangue , Benzamidas/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Pirróis/sangue , Pirróis/farmacocinética , Espectrometria de Massas em Tandem/métodos , Animais , Benzamidas/química , Estabilidade de Medicamentos , Limite de Detecção , Modelos Lineares , Masculino , Camundongos , Pirróis/química , Reprodutibilidade dos Testes
20.
Biomed Chromatogr ; 31(3)2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27526669

RESUMO

Sceletium tortuosum, is an indigenous herb of South Africa which is widely used as an herbal supplement in the treatment of anxiety and stress. Mesembrenone and mesembrine are the two main pharmacologically active alkaloids present in the extract. Despite the wide therapeutic applications of Sceletium extract, there are no reports of in vivo pharmacokinetic properties or analytical methods to quantify these two important alkaloids in plasma. Therefore, the current study aimed to develop and validate a simple and sensitive analytical method for simultaneous quantification of mesembrenone and mesembrine in mouse plasma. Ultra-high-performance liquid chromatography-mass spectrometry (UHPLC/QToF-MS) was employed to achieve our objectives. The compounds were extracted using protein precipitation by methanol (100%) with quinine as an internal standard. The lower limit of quantification for both the compounds was 10 ng/mL. The extraction recovery was between 87 and 93% for both compounds with no matrix effects on the analysis. The accuracy was between 89.5 and 106% and precision was <12.6% for all quality control samples. This validated method was successfully applied to evaluate the i.v. plasma pharmacokinetics of mesembrine and mesembrenone in mouse. However, the oral bioavailability of these alkaloids was poor and the plasma levels were below the detection limits.


Assuntos
Alcaloides/sangue , Alcaloides Indólicos/sangue , Animais , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas , Camundongos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa