Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
Neuroimage ; 300: 120850, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39260782

RESUMO

Non-invasive myelin water fraction (MWF) and g-ratio mapping using microstructural MRI have the potential to offer critical insights into brain microstructure and our understanding of neuroplasticity and neuroinflammation. By leveraging a unique panel of variably hypomyelinating mouse strains, we validated a high-resolution, model-free image reconstruction method for whole-brain MWF mapping. Further, by employing a bipolar gradient echo MRI sequence, we achieved high spatial resolution and robust mapping of MWF and g-ratio across the whole mouse brain. Our regional white matter-tract specific analyses demonstrated a graded decrease in MWF in white matter tracts which correlated strongly with myelin basic protein gene (Mbp) mRNA levels. Using these measures, we derived the first sensitive calibrations between MWF and Mbp mRNA in the mouse. Minimal changes in axonal density supported our hypothesis that observed MWF alterations stem from hypomyelination. Overall, our work strongly emphasizes the potential of non-invasive, MRI-derived MWF and g-ratio modeling for both preclinical model validation and ultimately translation to humans.


Assuntos
Imageamento por Ressonância Magnética , Proteína Básica da Mielina , Bainha de Mielina , Substância Branca , Animais , Bainha de Mielina/metabolismo , Camundongos , Proteína Básica da Mielina/metabolismo , Proteína Básica da Mielina/genética , Imageamento por Ressonância Magnética/métodos , Substância Branca/diagnóstico por imagem , Substância Branca/metabolismo , Masculino , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Feminino
2.
Br J Haematol ; 204(3): 1005-1016, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38083818

RESUMO

Immune-mediated thrombotic thrombocytopenic purpura (iTTP) is a rare condition caused by severe ADAMTS13 deficiency, leading to platelet aggregation and thrombosis. Despite treatment, patients are prone to cognitive impairment and depression. We investigated brain changes in iTTP patients during remission using advanced magnetic resonance imaging (MRI) techniques, correlating these changes with mood and neurocognitive tests. Twenty iTTP patients in remission (30 days post-haematological remission) were compared with six healthy controls. MRI scans, including standard and specialized sequences, were conducted to assess white matter health. Increased T1 relaxation times were found in the cingulate cortex (p < 0.05), and elevated T2 relaxation times were observed in the cingulate cortex, frontal, parietal and temporal lobes (p < 0.05). Pathological changes in these areas are correlated with impaired cognitive and depressive scores in concentration, short-term memory and verbal memory. This study highlights persistent white matter damage in iTTP patients, potentially contributing to depression and cognitive impairment. Key regions affected include the frontal lobe and cingulate cortex. These findings have significant implications for the acute and long-term management of iTTP, suggesting a need for re-evaluation of treatment approaches during both active phases and remission. Further research is warranted to enhance our understanding of these complexities.


Assuntos
Disfunção Cognitiva , Púrpura Trombocitopênica Trombótica , Substância Branca , Humanos , Púrpura Trombocitopênica Trombótica/terapia , Proteína ADAMTS13
3.
Magn Reson Med ; 91(3): 1043-1056, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38010053

RESUMO

PURPOSE: To investigate the prospects of a multigradient-echo (mGRE) acquisition for in vivo myelin water imaging at 0.55 T. METHODS: Scans were performed on the brain of four healthy volunteers at 0.55 and 3 T, using a 3D mGRE sequence. The myelin water fraction (MWF) was calculated for both field strengths using a nonnegative least squares (NNLS) algorithm, implemented in the qMRLab suite. The quality of these maps as well as single-voxel fits were compared visually for 0.55 and 3 T. RESULTS: The obtained MWF values at 0.55 T are consistent with previously reported ones at higher field strengths. The MWF maps are a considerable improvement over the ones at 3 T. Example fits show that 0.55 T data is better described by an exponential model than 3 T data, making the assumed multi-exponential model of the NNLS algorithm more accurate. CONCLUSION: This first assessment shows that mGRE myelin water imaging at 0.55 T is feasible and has the potential to yield better results than at higher fields.


Assuntos
Bainha de Mielina , Água , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico/métodos
4.
Magn Reson Med ; 91(6): 2483-2497, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38342983

RESUMO

PURPOSE: We introduced a novel reconstruction network, jointly unrolled cross-domain optimization-based spatio-temporal reconstruction network (JUST-Net), aimed at accelerating 3D multi-echo gradient-echo (mGRE) data acquisition and improving the quality of resulting myelin water imaging (MWI) maps. METHOD: An unrolled cross-domain spatio-temporal reconstruction network was designed. The main idea is to combine frequency and spatio-temporal image feature representations and to sequentially implement convolution layers in both domains. The k-space subnetwork utilizes shared information from adjacent frames, whereas the image subnetwork applies separate convolutions in both spatial and temporal dimensions. The proposed reconstruction network was evaluated for both retrospectively and prospectively accelerated acquisition. Furthermore, it was assessed in simulation studies and real-world cases with k-space corruptions to evaluate its potential for motion artifact reduction. RESULTS: The proposed JUST-Net enabled highly reproducible and accelerated 3D mGRE acquisition for whole-brain MWI, reducing the acquisition time from fully sampled 15:23 to 2:22 min within a 3-min reconstruction time. The normalized root mean squared error of the reconstructed mGRE images increased by less than 4.0%, and the correlation coefficients for MWI showed a value of over 0.68 when compared to the fully sampled reference. Additionally, the proposed method demonstrated a mitigating effect on both simulated and clinical motion-corrupted cases. CONCLUSION: The proposed JUST-Net has demonstrated the capability to achieve high acceleration factors for 3D mGRE-based MWI, which is expected to facilitate widespread clinical applications of MWI.


Assuntos
Bainha de Mielina , Água , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos
5.
NMR Biomed ; : e5235, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39086258

RESUMO

The purpose of this study is to demonstrate that T2-weighted imaging with very long echo time (TE > 300 ms) can provide relevant information in neurodegenerative/inflammatory disorder. Twenty patients affected by relapsing-remitting multiple sclerosis with stable disease course underwent 1.5 T 3D FLAIR, 3D T1-weighted, and a multi-echo sequence with 32 echoes (TE = 10-320 ms). Focal lesions (FL) were identified on FLAIR. T1-images were processed to segment deep gray matter (dGM), white matter (WM), FL sub-volumes with T1 hypo-intensity (T1FL), and dGM volumes (atrophy). Clinical-radiological parameters included Expanded Disability Status Scale (EDSS), disease duration, patient age, T1FL, and dGM atrophy. Correlation analysis was performed between the mean signal intensity (SI) computed on the non-lesional dGM and WM at different TE versus the clinical-radiological parameters. Multivariable linear regressions were fitted to the data to assess the association between the dependent variable EDSS and the independent variables obtained by T1FL lesion load and the mean SI of dGM and WM at the different TE. A clear trend is observed, with a systematic strengthening of the significance of the correlation at longer TE for all the relationships with the clinical-radiological parameters, becoming significant (p < 0.05) for EDSS, T1FL volumes, and dGM atrophy. Multivariable linear regressions show that at shorter TE, the SI of the T2-weighted sequences is not relevant for describing the EDSS variability while the T1FL volumes are relevant, and vice versa, at very-long TEs (around 300 ms); the SI of the T2-weighted sequences significantly (p < 0.05) describes the EDSS variability. By very long TE, the SI primarily originates from water with a T2 longer than 250 ms and/or free water, which may be arising from the perivascular space (PVS). Very-long T2-weighting might detect dilated PVS and represent an unexplored MR approach in neurofluid imaging of neurodegenerative/inflammatory diseases.

6.
J Magn Reson Imaging ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38445838

RESUMO

BACKGROUND: Intrauterine growth restriction (IUGR) is an obstetrical condition where a fetus has not achieved its genetic potential. A consequence of IUGR is a decrease in brain myelin content. Myelin water imaging (MWI) has been used to assess fetal myelin water fraction (MWF) and might potentially assess myelination changes associated with IUGR. PURPOSE: To quantify and compare the MWF of non-IUGR and IUGR fetal guinea pigs (GPs) in late gestation. STUDY TYPE: Prospective animal model. ANIMAL MODEL: Dunkin-Hartley GP model of spontaneous IUGR (mean ± SD: 60 ± 1.2 days gestation; 19 IUGR, 52 control). FIELD STRENGTH/SEQUENCE: Eight spoiled gradient-recalled (SPGR) gradient echo volumes (flip angles [α]: 2°-16°), and two sets of eight balanced steady-state free precession (bSSFP) gradient echo volumes (α: 8° - 64°), at 0° and 180° phase increments, at 3.0 T. ASSESSMENT: MWF maps were generated for each fetal GP brain using multicomponent driven equilibrium single pulse observation of T1 /T2 (mcDESPOT). MWF was quantified in the fetal corpus callosum (CC), fornix (FOR), parasagittal white matter (PSW), and whole fetal brain. STATISTICAL TESTS: Linear regression was performed between five fetal IUGR markers (body volume, body-to-pregnancy volume ratio, brain-to-liver volume ratio, brain-to-placenta volume ratio, and brain-to-body volume ratio) and MWF (coefficient of determination, R2 ). A t-test with a linear mixed model compared the MWF of non-IUGR and IUGR fetal GPs (significance was determined at α < 0.05). RESULTS: The MWF of the control fetuses are (mean ± SD): 0.23 ± 0.02 (CC), 0.31 ± 0.02 (FOR), 0.28 ± 0.02 (PSW), and 0.20 ± 0.01 (whole brain). The MWF of the IUGR fetuses are (mean ± SD): 0.19 ± 0.02 (CC), 0.27 ± 0.01 (FOR), 0.24 ± 0.03 (PSW), and 0.16 ± 0.01 (whole brain). Significant differences in MWF were found between the non-IUGR and IUGR fetuses in every comparison. DATA CONCLUSION: The mean MWF of IUGR fetal GPs is significantly lower than non-IUGR fetal GPs. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.

7.
Neuroimage ; 266: 119824, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36539169

RESUMO

In this study, we optimized the variable flip angle (VFA) acquisition scheme using numerical simulations to shorten the acquisition time of multicompartment relaxometry for myelin water imaging (MCR-MWI) to a clinically practical range in the absence of advanced image reconstruction methods. As the primary objective of this study, the test-retest repeatability of myelin water fraction (MWF) measurements of MCR-MWI is evaluated on three gradient echo (GRE) sequence settings using the optimized VFA schemes with different echo times and repetition times, emulating various scanner setups. The cross-protocol reproducibility of MCR-MWI and MCR with diffusion-informed myelin water imaging (MCR-DIMWI) is also examined. As a secondary objective, we explore the bundle-specific profiles of various microstructural parameters from MCR-(DI)MWI and their cross-correlations to determine if these parameters possess supplementary microstructure information beyond myelin concentration. Numerical simulations indicate that MCR-MWI can be performed with a minimum of three flip angles covering a wide range of T1 weightings without adding significant bias. This is supported by the results of an in vivo experiment, allowing whole-brain 1.5 mm isotropic MWF maps to be acquired in 9 min, reducing the total scan time to 40% of the original implementation without significant quality degradation. Good test-retest repeatability is observed for MCR-MWI for all three GRE protocols. While good correlations can also be found in MWF across protocols, systematic differences are observed. Bundle-specific MWF analysis reveals that certain white matter bundles are similar in all participants. We also found that microstructure relaxation parameters have low linear correlations with MWF. MCR-MWI is a reproducible measure of myelin. However, attention should be paid to the protocol related MWF differences when comparing different studies, as the MWF bias up to 0.5% can be observed across the protocols examined in this work.


Assuntos
Bainha de Mielina , Água , Humanos , Bainha de Mielina/metabolismo , Água/análise , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem
8.
Magn Reson Med ; 89(5): 1809-1824, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36511247

RESUMO

PURPOSE: We investigated the correlation, reproducibility, and effect of white matter fiber orientation for three myelin-sensitive MRI techniques: magnetization transfer ratio (MTR), inhomogeneous magnetization transfer ratio (ihMTR), and gradient and spin echo-derived myelin water fraction (MWF). METHODS: We measured the three metrics in 17 white and three deep grey matter regions in 17 healthy adults at 3 T. RESULTS: We found a strong correlation between ihMTR and MTR (r = 0.70, p < 0.001) and ihMTR and MWF (r = 0.79, p < 0.001), and a weaker correlation between MTR and MWF (r = 0.54, p < 0.001). The dynamic range in white matter was greatest for MWF (2.0%-27.5%), followed by MTR (14.4%-23.2%) and then ihMTR (1.2%-5.4%). The average scan-rescan coefficient of variation for white matter regions was 0.6% MTR, 0.3% ihMTR, and 0.7% MWF in metric units; however, when adjusted by the dynamic range, these became 6.3%, 6.1% and 2.8%, respectively. All three metrics varied with fiber direction: MWF and ihMTR were lower in white matter fibers perpendicular to B0 by 6% and 1%, respectively, compared with those parallel, whereas MTR was lower by 0.5% at about 40°, with the highest values at 90°. However, separating the apparent orientation dependence by white matter region revealed large dissimilarities in the trends, suggesting that real differences in myelination between regions are confounding the apparent orientation dependence measured using this method. CONCLUSION: The strong correlation between ihMTR and MWF suggests that these techniques are measuring the same myelination; however, the larger dynamic range of MWF may provide more power to detect small differences in myelin.


Assuntos
Bainha de Mielina , Substância Branca , Humanos , Adulto , Reprodutibilidade dos Testes , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Substância Branca/diagnóstico por imagem , Água , Biomarcadores
9.
Magn Reson Med ; 89(1): 286-298, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36121015

RESUMO

PURPOSE: To develop an efficient algorithm for multicomponent MR fingerprinting (MC-MRF) reconstructions directly from highly undersampled data without making prior assumptions about tissue relaxation times and expected number of tissues. METHODS: The proposed method reconstructs MC-MRF maps from highly undersampled data by iteratively applying a joint-sparsity constraint to the estimated tissue components. Intermediate component maps are obtained by a low-rank multicomponent alternating direction method of multipliers (MC-ADMM) including the non-negativity of tissue weights as an extra regularization term. Over iterations, the used dictionary compression is adjusted. The proposed method (k-SPIJN) is compared with a two-step approach in which image reconstruction and multicomponent estimations are performed sequentially and tested in numerical simulations and in vivo by applying different undersampling factors in eight healthy volunteers. In the latter case, fully sampled data serves as the reference. RESULTS: The proposed method shows improved precision and accuracy in simulations compared with a state-of-art sequential approach. Obtained in vivo magnetization fraction maps for different tissue types show reduced systematic errors and reduced noise-like effects. Root mean square errors in estimated magnetization fraction maps significantly reduce from 13.0% ± $$ \pm $$ 5.8% with the conventional, two-step approach to 9.6% ± $$ \pm $$ 3.9% and 9.6% ± $$ \pm $$ 3.2% with the proposed MC-ADMM and k-SPIJN methods, respectively. Mean standard deviation in homogeneous white matter regions reduced significantly from 8.6% to 2.9% (two step vs. k-SPIJN). CONCLUSION: The proposed MC-ADMM and k-SPIJN reconstruction methods estimate MC-MRF maps from highly undersampled data resulting in improved image quality compared with the existing method.


Assuntos
Compressão de Dados , Processamento de Imagem Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Compressão de Dados/métodos , Algoritmos
10.
J Magn Reson Imaging ; 57(6): 1856-1864, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36239714

RESUMO

BACKGROUND: Fetal myelination assessment is important for understanding neurodevelopment and neurodegeneration. Myelin water imaging (MWI) quantifies myelin water fraction (MWF), a validated marker for myelin content, and has been used to assess brain myelin in children and neonates. PURPOSE: To demonstrate that MWI can quantify MWF in fetal guinea pigs (GPs). STUDY TYPE: Animal model. ANIMAL MODEL: Nine pregnant, Dunkin-Hartley GPs with 31 fetuses (mean ± standard deviation = 60 ± 1.5 days gestation). FIELD STRENGTH/SEQUENCE: 3D spoiled gradient echo and balanced steady-state free precession sequences at 3.0 T. ASSESSMENT: MWF maps were reconstructed for maternal and fetal GP brains using the multicomponent driven equilibrium single pulse observation of T1 and T2 (mcDESPOT) approach. Myelin basic protein (MBP) stain provided histological validation of the MWF. Regions of interest were placed in the maternal corpus callosum (CC), maternal fornix (FOR), fetal CC, and fetal FOR in MWF maps and MBP stains. STATISTICAL TESTS: Linear regression between MWF and MBP stain intensity (SI) of all four regions (coefficient of determination, R2 ). A paired t-test compared the MWF of maternal and mean fetal CC, MBP SI of maternal and mean fetal CC, MWF of maternal and mean fetal FOR, MBP SI of maternal and mean fetal FOR. A paired t-test with a linear mixed model compared the MWF of fetal CC and fetal FOR, and MBP SI of fetal CC and fetal FOR. A  P value < 0.0083 was considered statistically significant. RESULTS: The mean MWF of the analyzed regions are as follows (mean ± standard deviation): 0.338 + 0.016 (maternal CC), 0.340 ± 0.017 (maternal FOR), 0.214 ± 0.016 (fetal CC), and 0.305 ± 0.025 (fetal FOR). MWF correlated with MBP SI in all regions (R2  = 0.81). Significant differences were found between MWF and MBP SI of maternal and fetal CC, and MWF and MBP SI of fetal CC and fetal FOR. DATA CONCLUSION: This study demonstrated the feasibility of MWI in assessing fetal brain myelin content. EVIDENCE LEVEL: 2 Technical Efficacy: Stage 1.


Assuntos
Bainha de Mielina , Água , Gravidez , Feminino , Cobaias , Animais , Bainha de Mielina/metabolismo , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo
11.
Neuroimage ; 263: 119644, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36170952

RESUMO

White matter (WM) neuroplasticity in the human brain has been tracked non-invasively using advanced magnetic resonance imaging techniques, with increasing evidence for improved axonal transmission efficiency as a central mechanism. The current study is the culmination of a series of studies, which characterized the structure-function relationship of WM transmission efficiency in the cortico-spinal tract (CST) during motor learning. Here, we test the hypothesis that increased transmission efficiency is linked directly to increased myelination using myelin water imaging (MWI). MWI was used to evaluate neuroplasticity-related improvements in the CST. The MWI findings were then compared to diffusion tensor imaging (DTI) results, with the secondary hypothesis that radial diffusivity (RD) would have a stronger relationship than axial diffusivity (AD) if the changes were due to increased myelination. Both MWI and RD data showed the predicted pattern of significant results, strongly supporting that increased myelination plays a central role in WM neuroplasticity.


Assuntos
Substância Branca , Humanos , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Imagem de Tensor de Difusão/métodos , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Água
12.
Neuroimage ; 264: 119717, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36367497

RESUMO

PURPOSE: Reconstruction of high quality myelin water imaging (MWI) maps is challenging, particularly for data acquired using multi-echo gradient echo (mGRE) sequences. A non-linear least squares fitting (NLLS) approach has often been applied for MWI. However, this approach may produce maps with limited detail and, in some cases, sub-optimal signal to noise ratio (SNR), due to the nature of the voxel-wise fitting. In this study, we developed a novel, unsupervised learning method called self-labelled encoder-decoder (SLED) to improve gradient echo-based MWI data fitting. METHODS: Ultra-high resolution, MWI data was collected from five mouse brains with variable levels of myelination, using a mGRE sequence. Imaging data was acquired using a 7T preclinical MRI system. A self-labelled, encoder-decoder network was implemented in TensorFlow for calculation of myelin water fraction (MWF) based on the mGRE signal decay. A simulated MWI phantom was also created to evaluate the performance of MWF estimation. RESULTS: Compared to NLLS, SLED demonstrated improved MWF estimation, in terms of both stability and accuracy in phantom tests. In addition, SLED produced less noisy MWF maps from high resolution MR microscopy images of mouse brain tissue. It specifically resulted in lower noise amplification for all mouse genotypes that were imaged and yielded mean MWF values in white matter ROIs that were highly correlated with those derived from standard NLLS fitting. Lastly, SLED also exhibited higher tolerance to low SNR data. CONCLUSION: Due to its unsupervised and self-labeling nature, SLED offers a unique alternative to analyze gradient echo-based MWI data, providing accurate and stable MWF estimations.


Assuntos
Bainha de Mielina , Substância Branca , Animais , Camundongos , Água , Substância Branca/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem
13.
Magn Reson Med ; 87(5): 2521-2535, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34958690

RESUMO

PURPOSE: Multicomponent analysis of MRI T2 relaxation time (mcT2 ) is commonly used for estimating myelin content by separating the signal at each voxel into its underlying distribution of T2 values. This voxel-based approach is challenging due to the large ambiguity in the multi-T2 space and the low SNR of MRI signals. Herein, we present a data-driven mcT2 analysis, which utilizes the statistical strength of identifying spatially global mcT2 motifs in white matter segments before deconvolving the local signal at each voxel. METHODS: Deconvolution is done using a tailored optimization scheme, which incorporates the global mcT2 motifs without additional prior assumptions regarding the number of microscopic components. The end results of this process are voxel-wise myelin water fraction maps. RESULTS: Validations are shown for computer-generated signals, uniquely designed subvoxel mcT2 phantoms, and in vivo human brain. Results demonstrated excellent fitting accuracy, both for the numerical and the physical mcT2 phantoms, exhibiting excellent agreement between calculated myelin water fraction and ground truth. Proof-of-concept in vivo validation is done by calculating myelin water fraction maps for white matter segments of the human brain. Interscan stability of myelin water fraction values was also estimated, showing good correlation between scans. CONCLUSION: We conclude that studying global tissue motifs prior to performing voxel-wise mcT2 analysis stabilizes the optimization scheme and efficiently overcomes the ambiguity in the T2 space. This new approach can improve myelin water imaging and the investigation of microstructural compartmentation in general.


Assuntos
Bainha de Mielina , Água , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina/química , Água/química
14.
Magn Reson Med ; 87(2): 915-931, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34490909

RESUMO

PURPOSE: The decomposition of multi-exponential decay data into a T2 spectrum poses substantial challenges for conventional fitting algorithms, including non-negative least squares (NNLS). Based on a combination of the resolution limit constraint and machine learning neural network algorithm, a data-driven and highly tailorable analysis method named spectrum analysis for multiple exponentials via experimental condition oriented simulation (SAME-ECOS) was proposed. THEORY AND METHODS: The theory of SAME-ECOS was derived. Then, a paradigm was presented to demonstrate the SAME-ECOS workflow, consisting of a series of calculation, simulation, and model training operations. The performance of the trained SAME-ECOS model was evaluated using simulations and six in vivo brain datasets. The code is available at https://github.com/hanwencat/SAME-ECOS. RESULTS: Using NNLS as the baseline, SAME-ECOS achieved over 15% higher overall cosine similarity scores in producing the T2 spectrum, and more than 10% lower mean absolute error in calculating the myelin water fraction (MWF), as well as demonstrated better robustness to noise in the simulation tests. Applying to in vivo data, MWF from SAME-ECOS and NNLS was highly correlated among all study participants. However, a distinct separation of the myelin water peak and the intra/extra-cellular water peak was only observed in the mean T2 spectra determined using SAME-ECOS. In terms of data processing speed, SAME-ECOS is approximately 30 times faster than NNLS, achieving a whole-brain analysis in 3 min. CONCLUSION: Compared with NNLS, the SAME-ECOS method yields much more reliable T2 spectra in a dramatically shorter time, increasing the feasibility of multi-component T2 decay analysis in clinical settings.


Assuntos
Bainha de Mielina , Água , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Análise Espectral
15.
NMR Biomed ; 35(7): e4668, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34936147

RESUMO

Long acquisition times preclude the application of multiecho spin echo (MESE) sequences for myelin water fraction (MWF) mapping in daily clinical practice. In search of alternative methods, previous studies of interest explored the biophysical modeling of MWF from measurements of different tissue properties that can be obtained in scan times shorter than those required for the MESE. In this work, a novel data-driven estimation of MWF maps from fast relaxometry measurements is proposed and investigated. T1 and T2 relaxometry maps were acquired in a cohort of 20 healthy subjects along with a conventional MESE sequence. Whole-brain quantitative mapping was achieved with a fast protocol in 6 min 24 s. Reference MWF maps were derived from the MESE sequence (TA = 11 min 17 s) and their data-driven estimation from relaxometry measurements was investigated using three different modeling strategies: two general linear models (GLMs) with linear and quadratic regressors, respectively; a random forest regression model; and two deep neural network architectures, a U-Net and a conditional generative adversarial network (cGAN). Models were validated using a 10-fold crossvalidation. The resulting maps were visually and quantitatively compared by computing the root mean squared error (RMSE) between the estimated and reference MWF maps, the intraclass correlation coefficients (ICCs) between corresponding MWF values in different brain regions, and by performing Bland-Altman analysis. Qualitatively, the estimated maps appear to generally provide a similar, yet more blurred MWF contrast in comparison with the reference, with the cGAN model best capturing MWF variabilities in small structures. By estimating the average adjusted coefficient of determination of the GLM with quadratic regressors, we showed that 87% of the variability in the MWF values can be explained by relaxation times alone. Further quantitative analysis showed an average RMSE smaller than 0.1% for all methods. The ICC was greater than 0.81 for all methods, and the bias smaller than 2.19%. It was concluded that this work confirms the notion that relaxometry parameters contain a large part of the information on myelin water and that MWF maps can be generated from T1 /T2 data with minimal error. Among the investigated modeling approaches, the cGAN provided maps with the best trade-off between accuracy and blurriness. Fast relaxometry, like the 6 min 24 s whole-brain protocol used in this work in conjunction with machine learning, may thus have the potential to replace time-consuming MESE acquisitions.


Assuntos
Processamento de Imagem Assistida por Computador , Bainha de Mielina , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina/química , Água/química
16.
J Magn Reson Imaging ; 56(5): 1548-1556, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35353434

RESUMO

BACKGROUND: Myelin water imaging (MWI) using MRI has been introduced as a method to quantify the integrity of myelin in vivo. However, the investigation of its potential to probe myelin changes has been limited. PURPOSE: To determine the myelin change using MWI in the corticospinal tract (CST) during the rehabilitation of stroke patients. STUDY TYPE: Longitudinal. POPULATION: A total of 24 stroke patients within 6 months from the onset (64.3 ± 16.1 years, 14 women, 10 men) and 10 healthy volunteers (27.0 ± 2.2 years, 2 women, 8 men). FIELD STRENGTH/SEQUENCE: Three-dimensional multiecho gradient echo sequence and diffusion-weighted echoplanar imaging sequence at 3 T. ASSESSMENT: The changes of myelin water fraction (MWF) and fractional anisotropy (FA) during rehabilitation were analyzed in the CST and other regions using tractography software and region of interest drawings by the radiologist. STATISTICAL TESTS: A paired t-test was performed to investigate the change of MRI metrics during rehabilitation. In addition, an independent two-sample t-test was performed to investigate the effects of different rehabilitation protocols. A P-value <0.05 was considered significant. RESULTS: In the CST, MWF significantly changed from 5.83 ± 0.91% to 6.23 ± 0.97% after rehabilitation while changes of FA (0.442 ± 0.038 to 0.443 ± 0.035) were not significant (P = 0.656). The rate of change in MWF and FA, which were 6.69% and 0.439% respectively, were significantly different. Other regions did not show significant changes (range of MWF change: -3.44% to -1.61%, range of FA change: -1.39% to 0.79%, and range of P-value: 0.144-0.761). Further analysis showed that those with additional robot-assisted rehabilitation had a significantly larger MWF change than those with conventional rehabilitation only (rate of change: 11.2% vs. 3.2%). DATA CONCLUSION: The feasibility of using MWI to monitor myelin content was demonstrated by showing the MWF changes during rehabilitation. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Bainha de Mielina , Acidente Vascular Cerebral , Anisotropia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Acidente Vascular Cerebral/diagnóstico por imagem , Água
17.
Brain ; 144(6): 1684-1696, 2021 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-33693571

RESUMO

Damage to the myelin sheath and the neuroaxonal unit is a cardinal feature of multiple sclerosis; however, a detailed characterization of the interaction between myelin and axon damage in vivo remains challenging. We applied myelin water and multi-shell diffusion imaging to quantify the relative damage to myelin and axons (i) among different lesion types; (ii) in normal-appearing tissue; and (iii) across multiple sclerosis clinical subtypes and healthy controls. We also assessed the relation of focal myelin/axon damage with disability and serum neurofilament light chain as a global biological measure of neuroaxonal damage. Ninety-one multiple sclerosis patients (62 relapsing-remitting, 29 progressive) and 72 healthy controls were enrolled in the study. Differences in myelin water fraction and neurite density index were substantial when lesions were compared to healthy control subjects and normal-appearing multiple sclerosis tissue: both white matter and cortical lesions exhibited a decreased myelin water fraction and neurite density index compared with healthy (P < 0.0001) and peri-plaque white matter (P < 0.0001). Periventricular lesions showed decreased myelin water fraction and neurite density index compared with lesions in the juxtacortical region (P < 0.0001 and P < 0.05). Similarly, lesions with paramagnetic rims showed decreased myelin water fraction and neurite density index relative to lesions without a rim (P < 0.0001). Also, in 75% of white matter lesions, the reduction in neurite density index was higher than the reduction in the myelin water fraction. Besides, normal-appearing white and grey matter revealed diffuse reduction of myelin water fraction and neurite density index in multiple sclerosis compared to healthy controls (P < 0.01). Further, a more extensive reduction in myelin water fraction and neurite density index in normal-appearing cortex was observed in progressive versus relapsing-remitting participants. Neurite density index in white matter lesions correlated with disability in patients with clinical deficits (P < 0.01, beta = -10.00); and neurite density index and myelin water fraction in white matter lesions were associated to serum neurofilament light chain in the entire patient cohort (P < 0.01, beta = -3.60 and P < 0.01, beta = 0.13, respectively). These findings suggest that (i) myelin and axon pathology in multiple sclerosis is extensive in both lesions and normal-appearing tissue; (ii) particular types of lesions exhibit more damage to myelin and axons than others; (iii) progressive patients differ from relapsing-remitting patients because of more extensive axon/myelin damage in the cortex; and (iv) myelin and axon pathology in lesions is related to disability in patients with clinical deficits and global measures of neuroaxonal damage.


Assuntos
Axônios/patologia , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Bainha de Mielina/patologia , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico por imagem , Neuroimagem/métodos , Água
18.
Neuroimage ; 232: 117897, 2021 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-33621694

RESUMO

Myelin water imaging techniques based on multi-compartment relaxometry have been developed as an important tool to measure myelin concentration in vivo, but are limited by the long scan time of multi-contrast multi-echo acquisition. In this work, a fast imaging technique, termed variable flip angle Echo Planar Time-Resolved Imaging (vFA-EPTI), is developed to acquire multi-echo and multi-flip-angle gradient-echo data with significantly reduced acquisition time, providing rich information for multi-compartment analysis of gradient-echo myelin water imaging (GRE-MWI). The proposed vFA-EPTI method achieved 26 folds acceleration with good accuracy by utilizing an efficient continuous readout, optimized spatiotemporal encoding across echoes and flip angles, as well as a joint subspace reconstruction. An approach to estimate off-resonance field changes between different flip-angle acquisitions was also developed to ensure high-quality joint reconstruction across flip angles. The accuracy of myelin water fraction (MWF) estimate under high acceleration was first validated by a retrospective undersampling experiment using a lengthy fully-sampled data as reference. Prospective experiments were then performed where whole-brain MWF and multi-compartment quantitative maps were obtained in 5 min at 1.5 mm isotropic resolution and 24 min at 1 mm isotropic resolution at 3T. Additionally, ultra-high resolution data at 600 µm isotropic resolution were acquired at 7T, which show detailed structures within the cortex such as the line of Gennari, demonstrating the ability of the proposed method for submillimeter GRE-MWI that can be used to study cortical myeloarchitecture in vivo.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina/metabolismo , Humanos , Estudos Retrospectivos , Água/metabolismo
19.
Magn Reson Med ; 85(1): 209-222, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32720406

RESUMO

PURPOSE: Although several MRI methods have been explored to achieve in vivo myelin quantification, imaging the whole brain in clinically acceptable times and sufficiently high resolution remains challenging. To address this problem, this work investigates the acceleration of multi-echo T2 acquisitions based on the multi-echo gradient and spin echo (GRASE) sequence using CAIPIRINHA undersampling and adapted k-space reordering patterns. METHODS: A prototype multi-echo GRASE sequence supporting CAIPIRINHA parallel imaging was implemented. Multi-echo T2 data were acquired from 12 volunteers using the implemented sequence (1.6 × 1.6 × 1.6 mm3 , 84 slices, acquisition time [TA] = 10:30 min) and a multi-echo spin echo (MESE) sequence as reference (1.6 × 1.6 × 3.2 mm3 , single-slice, TA = 5:41 min). Myelin water fraction (MWF) maps derived from both acquisitions were compared via correlation and Bland-Altman analyses. In addition, scan-rescan datasets were acquired to evaluate the repeatability of the derived maps. RESULTS: Resulting maps from the MESE and multi-echo GRASE sequences were found to be correlated (r = 0.83). The Bland-Altman analysis revealed a mean bias of -0.2% (P = .24) with the limits of agreement ranging from -3.7% to 3.3%. The Pearson's correlation coefficient among MWF values obtained from the scan-rescan datasets was found to be 0.95 and the mean bias equal to 0.11% (P = .32), indicating good repeatability of the retrieved maps. CONCLUSION: By combining a 3D multi-echo GRASE sequence with CAIPIRINHA sampling, whole-brain MWF maps were obtained in 10:30 min with 1.6 mm isotropic resolution. The good correlation with conventional MESE-based maps demonstrates that the implemented sequence may be a promising alternative to time-consuming MESE acquisitions.


Assuntos
Processamento de Imagem Assistida por Computador , Bainha de Mielina , Água , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Humanos , Imageamento por Ressonância Magnética
20.
Magn Reson Med ; 85(2): 627-652, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32936494

RESUMO

Rapid and efficient transmission of electric signals among neurons of vertebrates is ensured by myelin-insulating sheaths surrounding axons. Human cognition, sensation, and motor functions rely on the integrity of these layers, and demyelinating diseases often entail serious cognitive and physical impairments. Magnetic resonance imaging radically transformed the way these disorders are monitored, offering an irreplaceable tool to noninvasively examine the brain structure. Several advanced techniques based on MRI have been developed to provide myelin-specific contrasts and a quantitative estimation of myelin density in vivo. Here, the vast offer of acquisition strategies developed to date for this task is reviewed. Advantages and pitfalls of the different approaches are compared and discussed.


Assuntos
Imageamento por Ressonância Magnética , Bainha de Mielina , Animais , Axônios , Encéfalo/diagnóstico por imagem , Meios de Contraste , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa