Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Arterioscler Thromb Vasc Biol ; 44(8): 1884-1894, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38899469

RESUMO

BACKGROUND: Vascular calcification is associated with increased mortality in patients with cardiovascular disease. Secondary calciprotein particles are believed to play a causal role in the pathophysiology of vascular calcification. The maturation time (T50) of calciprotein particles provides a measure of serum calcification propensity. We compared T50 between patients with ST-segment-elevated myocardial infarction and control subjects and studied the association of T50 with cardiovascular risk factors and outcome. METHODS: T50 was measured by nephelometry in 347 patients from the GIPS-III trial (Metabolic Modulation With Metformin to Reduce Heart Failure After Acute Myocardial Infarction: Glycometabolic Intervention as Adjunct to Primary Coronary Intervention in ST Elevation Myocardial Infarction: a Randomized Controlled Trial) and in 254 matched general population controls from PREVEND (Prevention of Renal and Vascular End-Stage Disease). We also assessed the association between T50 and left ventricular ejection fraction, as well as infarct size, the incidence of ischemia-driven reintervention during 5 years of follow-up, and serum nitrite as a marker of endothelial dysfunction. RESULTS: Patients with ST-segment-elevated myocardial infarction had a significantly lower T50 (ie, higher serum calcification propensity) compared with controls (T50: 289±63 versus 338±56 minutes; P<0.001). In patients with ST-segment-elevated myocardial infarction, lower T50 was associated with female sex, lower systolic blood pressure, lower total cholesterol, lower LDL (low-density lipoprotein) cholesterol, lower triglycerides, and higher HDL (high-density lipoprotein) cholesterol but not with circulating nitrite or nitrate. Ischemia-driven reintervention was associated with higher LDL (P=0.03) and had a significant interaction term for T50 and sex (P=0.005), indicating a correlation between ischemia-driven reintervention and T50 above the median in men and below the median in women, between 150 days and 5 years of follow-up. CONCLUSIONS: Serum calcification propensity is increased in patients with ST-segment-elevated myocardial infarction compared with the general population, and its contribution is more pronounced in women than in men. Its lack of/inverse association with nitrite and blood pressure confirms T50 to be orthogonal to traditional cardiovascular disease risk factors. Lower T50 was associated with a more favorable serum lipid profile, suggesting the involvement of divergent pathways of calcification stress and lipid stress in the pathophysiology of myocardial infarction.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Infarto do Miocárdio com Supradesnível do Segmento ST/sangue , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Biomarcadores/sangue , Fatores de Risco de Doenças Cardíacas , Calcificação Vascular/sangue , Calcificação Vascular/fisiopatologia , Medição de Risco , Fatores de Risco , Estudos de Casos e Controles , Fatores de Tempo , Função Ventricular Esquerda , Volume Sistólico
2.
Clin Chem Lab Med ; 62(5): 929-938, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38044587

RESUMO

OBJECTIVES: Free light chain (FLC) assays and the ratio of κ/λ are recommended for diagnosis, prognosis and monitoring of plasma cell dyscrasias (PCD). Limited data exists on FLC clinical specificity in patients diagnosed with other conditions. METHODS: We assessed the κ, λ, and κ/λ FLC ratio using the FreeLite assay and the Sebia FLC ELISA assay in 176 patients with clinical presentations of fatigue, anemia, polyclonal hypergammaglobulinemia, joint disorders, kidney disease and non PCD-cancers with no monoclonal protein observed on serum protein electrophoresis or MASS-FIX immunoglobulin isotyping. Manufacturer defined reference intervals (RI) and glomerular filtration rate (GFR) specific RI (renal RI) were utilized. RESULTS: For the κ/λ ratio, 68.7 % (121/176) of specimens on the FreeLite and 87.5 % (154/176) of specimens on the Sebia assay were within RI. For κ, 68.2 % (120/176) and 72.2 % (127/176) of results were outside RI for FreeLite and Sebia respectively. For λ, 37.5 % (66/176) and 84.1 % (148/176) of FreeLite and Sebia results were outside RI. With FreeLite and Sebia, patients with kidney disease (n=25) had the highest κ/λ ratios. 44 patients (25.0 %) had GFR <60 mL/min/BSA. When renal RI were applied, 13.6 % had a FLCr outside the renal RI with FreeLite, and 4.5 % with Sebia. CONCLUSIONS: In a cohort of patients with signs and symptoms suggestive of PCDs, but ultimately diagnosed with other conditions, Sebia FLC had improved clinical specificity relative to FreeLite, if one was using an abnormal κ/λ ratio as a surrogate for monoclonality.


Assuntos
Nefropatias , Paraproteinemias , Humanos , Cadeias kappa de Imunoglobulina , Cadeias lambda de Imunoglobulina , Cadeias Leves de Imunoglobulina , Paraproteinemias/diagnóstico
3.
Int J Mol Sci ; 25(10)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38791208

RESUMO

The diagnosis of MS relies on a combination of imaging, clinical examinations, and biological analyses, including blood and cerebrospinal fluid (CSF) assessments. G-Oligoclonal bands (OCBs) are considered a "gold standard" for MS diagnosis due to their high sensitivity and specificity. Recent advancements have involved the introduced of kappa free light chain (k-FLC) assay into cerebrospinal fluid (CSF) and serum (S), along with the albumin quotient, leading to the development of a novel biomarker known as the "K-index" or "k-FLC index". The use of the K-index has been recommended to decrease costs, increase laboratory efficiency, and to skip potential subjective operator-dependent risk that could happen during the identification of OCBs profiles. This review aims to provide a comprehensive overview and analysis of recent scientific articles, focusing on updated methods for MS diagnosis with an emphasis on the utility of the K-index. Numerous studies indicate that the K-index demonstrates high sensitivity and specificity, often comparable to or surpassing the diagnostic accuracy of OCBs evaluation. The integration of the measure of the K-index with OCBs assessment emerges as a more precise method for MS diagnosis. This combined approach not only enhances diagnostic accuracy, but also offers a more efficient and cost-effective alternative.


Assuntos
Biomarcadores , Humanos , Bandas Oligoclonais/líquido cefalorraquidiano , Bandas Oligoclonais/sangue , Esclerose Múltipla/diagnóstico , Esclerose Múltipla/líquido cefalorraquidiano , Esclerose Múltipla/sangue , Sensibilidade e Especificidade , Cadeias kappa de Imunoglobulina/líquido cefalorraquidiano , Cadeias kappa de Imunoglobulina/sangue
4.
J Clin Immunol ; 43(6): 1185-1192, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36941491

RESUMO

PURPOSE: This study assessed whether measuring immunoglobulin G (IgG) from dried blood spots (DBSs) using nephelometry is a suitable remote monitoring method for patients with primary immunodeficiencies (PID). METHODS: Patients receiving immunoglobulin replacement therapy for PID were included in this non-interventional single-arm study (DRKS-ID: DRKS00020522) conducted in Germany from December 4, 2019, to December 22, 2020. Three blood samples, two capillary DBSs (one mail-transferred and the other direct-transferred to the laboratory), and one intravenous were collected from each patient. IgG levels were determined using nephelometry. IgG levels were summarized descriptively, and significant differences were assessed using Wilcoxon matched-pairs signed-rank tests. Correlation and agreement between IgG levels were assessed using Spearman correlation and Bland-Altman analyses, respectively. RESULTS: Among 135 included patients, IgG levels measured from DBS samples were lower than those measured in serum (p < 0.0001). There was no significant difference between IgG levels in direct- and mail-transferred DBS samples. There was a high degree of correlation between IgG levels in serum samples and DBS samples (r = 0.94-0.95). Although there was a bias for higher levels of IgG in serum than in DBS samples, most samples were within the 95% interval of agreement. There was a high degree of correlation between IgG levels measured in direct- and mail-transferred DBS samples (r = 0.96) with no bias based on the shipment process and most samples within the 95% interval of agreement. CONCLUSION: Monitoring IgG levels from DBS samples is a suitable alternative to the standard method, and results are not substantially affected by mailing DBS cards.


Assuntos
Teste em Amostras de Sangue Seco , Imunoglobulina G , Humanos , Teste em Amostras de Sangue Seco/métodos , Soro , Alemanha
5.
Clin Chem Lab Med ; 61(9): 1619-1622, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37027892

RESUMO

OBJECTIVES: Rheumatoid arthritis (RA) is a systemic autoimmune disease characterised by the presence of autoantibodies that are used for classification of the disease. Though routine diagnostics is commonly restricted to measuring rheumatoid factor (RF) and anti-citrullinated protein antibodies, detection of RF IgM, IgG and IgA isotypes, may increase the power of RA serodiagnosis by reducing the number of seronegative patients as well as provide prognostic information. The agglutination-based RF assays, such as nephelometry or turbidimetry, are unable to differentiate isotypes. We compared three different immunoassays used in current laboratory practice to detect RF isotypes. METHODS: We tested 117 consecutive serum samples that were positive for total RF at nephelometry, from 55 RA and 62 non-RA subjects. IgA, IgG, and IgM isotypes of RF were tested by immunoenzymatic (ELISA, Technogenetics), fluoroenzymatic (FEIA, ThermoFisher) and chemiluminescence (CLIA, YHLO Biotech Co.) immunoassays. RESULTS: Diagnostic performance differed considerably between the assays, especially with regard to RF IgG isotype. Agreement among methods by Cohen's kappa ranged from 0.05 (RF IgG CLIA vs. FEIA) to 0.846 (RF IgM CLIA vs. FEIA). CONCLUSIONS: The poor agreement observed in this study indicates substantial lack of comparability among assays for RF isotypes. Harmonization of these tests requires further efforts before their measurement can be used in clinical practice.


Assuntos
Artrite Reumatoide , Fator Reumatoide , Humanos , Isotipos de Imunoglobulinas , Artrite Reumatoide/diagnóstico , Autoanticorpos , Ensaio de Imunoadsorção Enzimática , Imunoglobulina G , Imunoglobulina M , Imunoglobulina A
6.
Scand J Clin Lab Invest ; 83(1): 60-63, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36448677

RESUMO

This study aimed to examine the agreement of the serum amyloid A (SAA) values determined using the ELISA test and the nephelometric automated method. This study included 80 serum samples obtained from patients with COVID-19. Samples were determined using ELISA and the nephelometric method. Wilcoxon signed ranks test showed a statistically significant difference in the calculated median values (Z = -2.432, p = 0.015). The correlation between methods was statistically significant (r = 0.603, p < 0.0001). Bland Altman analysis showed a bias of 56.6 mg/L and a relative bias of 7.4% between the methods. The results of this study indicate that further studies are needed that will examine the compliance between the ELISA and the nephelometric method for determining SAA, and the results must be carefully interpreted based on the method used.


Assuntos
COVID-19 , Proteína Amiloide A Sérica , Humanos , Proteína Amiloide A Sérica/análise , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática , Nefelometria e Turbidimetria
7.
Pediatr Nephrol ; 35(2): 279-285, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31680199

RESUMO

BACKGROUND: Cystatin C is a key GFR biomarker. Recently, Siemens recalibrated the assay based on certified reference material ERM-DA471/IFCC. The NIH-funded longitudinal chronic kidney disease in children (CKiD) study has > 3000 cystatin C measurements based on a pre-IFCC calibrator provided by Siemens. Since cystatin C values for CKiD are now standardized to IFCC certified reference material, it is important to relate the IFCC-calibrated results to the previous values so that there are no discontinuous results. METHODS: We diluted cystatin C ERM-DA471/IFCC (5.48 mg/L) into buffer and compared results with predicted ones. We then updated the cystatin C application on our BN II nephelometer to provide results based on pre-IFCC and IFCC calibrations of CKiD specimens simultaneously. We assayed 51 previously analyzed sera and 62 fresh additional specimens. RESULTS: The predicted concentrations from the IFCC standard were consistently 17% higher than the measured values using the pre-IFCC calibration (y = 1.1686x). Similarly, the re-run and fresh sample concentrations were 17% higher via the IFCC calibration than by the pre-IFCC calibration (y = 1.168x). There was very high reliability in the measurements using the previous calibration for re-run specimens (0.99) and for 33 pristine specimens using IFCC calibration (0.99). CONCLUSIONS: We confirm the recalibration proposed by Siemens. To convert pre-IFCC results to IFCC-calibrated concentrations, the value is multiplied by 1.17. Conversely, one divides IFCC-calibrated results by 1.17 to estimate GFR via previously published pre-IFCC CKiD eGFR equations. For older adolescents, cystatin C has already been standardized and can be directly applied to the CKD-EPI equations.


Assuntos
Cistatina C/análise , Nefelometria e Turbidimetria/normas , Humanos , Valores de Referência
8.
Scand J Clin Lab Invest ; 80(3): 230-235, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32108506

RESUMO

Apolipoprotein CIII (apoCIII) is associated with triglyceride (TG)-rich particles like VLDL and exerts an inhibitory effect of lipoprotein lipase. Increased levels are related to cardiovascular diseases and diabetes and therefore apoCIII has been proposed as a useful biomarker. Even if several commercial assays for measuring apoCIII in human plasma/serum are available, data is scarce concerning their reliability and none is used clinically. In the present study a comparative investigation has been done. Two ELISA-based methods (Cusabio Biotech and Assay Pro) and one nephelometric assay (Siemens Healthcare) were investigated. Serum and plasma samples were obtained from healthy volunteers and from samples sent to the Laboratory of Clinical Chemistry, preferably with higher levels of TGs. The Cusabio Biotech assay did not yield any valid results. However, both the methods from Assay Pro and Siemens Healthcare showed good performance with similar dynamic ranges. The latter assay had lower CV and required less work. In healthy individuals, apoCIII levels were not affected by fasting, freezing or thawing, nor did we find any gender differences. Individuals with elevated levels of TG displayed higher apoCIII values. Females with oral intake of contraceptives had higher levels. In conclusion, the nephelometric assay showed the best performance with the lowest CV, was less labor intensive than an assay based on ELISA and could therefore be suitable for clinical use.


Assuntos
Apolipoproteína C-III/sangue , Química Clínica/métodos , Diabetes Mellitus/sangue , Nefelometria e Turbidimetria/normas , Hepatopatia Gordurosa não Alcoólica/sangue , Triglicerídeos/sangue , Adulto , Idoso , Biomarcadores/sangue , Índice de Massa Corporal , Estudos de Casos e Controles , Química Clínica/normas , HDL-Colesterol/sangue , Anticoncepcionais Orais/administração & dosagem , Diabetes Mellitus/diagnóstico , Ensaio de Imunoadsorção Enzimática , Jejum/sangue , Humanos , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Manejo de Espécimes
9.
Sensors (Basel) ; 19(20)2019 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-31600932

RESUMO

Immunoassays have been widely used in scientific research and clinical diagnosis due to their versatile detection capability and high specificity. Immunoagglutination assays are kinds of immunoassay, which can simply and rapidly measure the concentration of analytes. In this work, we developed a low-cost micro-volume nephelometric system for quantitative immunoagglutination assays. We used off-the-shelf components to build the system, and the total cost of key components is only about 20 US dollars. The total detection volume in our system was as low as 3 µL, which could significantly reduce the reagent cost and required sample volume. We further evaluated the system performance via the immunoagglutination assay to measure the concentration of C-reactive protein, a plasma protein with levels rising in response to inflammation. The results demonstrated that our system could measure the concentration of analytes with relatively high sensitivity and precision within four minutes, and has high potential to be applied for clinical diagnostic tests.


Assuntos
Testes de Aglutinação/economia , Custos e Análise de Custo , Imunoensaio/economia , Nefelometria e Turbidimetria/economia , Proteína C-Reativa/análise , Humanos , Imageamento Tridimensional , Espalhamento de Radiação
10.
Molecules ; 24(22)2019 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-31766108

RESUMO

Since hyperactivity of the protein kinase DYRK1A is linked to several neurodegenerative disorders, DYRK1A inhibitors have been suggested as potential therapeutics for Down syndrome and Alzheimer's disease. Most published inhibitors to date suffer from low selectivity against related kinases or from unfavorable physicochemical properties. In order to identify DYRK1A inhibitors with improved properties, a series of new chemicals based on [b]-annulated halogenated indoles were designed, synthesized, and evaluated for biological activity. Analysis of crystal structures revealed a typical type-I binding mode of the new inhibitor 4-chlorocyclohepta[b]indol-10(5H)-one in DYRK1A, exploiting mainly shape complementarity for tight binding. Conversion of the DYRK1A inhibitor 8-chloro-1,2,3,9-tetrahydro-4H-carbazol-4-one into a corresponding Mannich base hydrochloride improved the aqueous solubility but abrogated kinase inhibitory activity.


Assuntos
Halogênios/química , Indóis/química , Indóis/farmacologia , Inibidores de Proteínas Quinases/química , Inibidores de Proteínas Quinases/farmacologia , Proteínas Serina-Treonina Quinases/química , Proteínas Tirosina Quinases/química , Desenho de Fármacos , Humanos , Simulação de Acoplamento Molecular , Simulação de Dinâmica Molecular , Estrutura Molecular , Proteínas Serina-Treonina Quinases/antagonistas & inibidores , Proteínas Tirosina Quinases/antagonistas & inibidores , Solubilidade , Análise Espectral , Relação Estrutura-Atividade , Quinases Dyrk
11.
Clin Chem Lab Med ; 56(7): 1071-1080, 2018 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-29455184

RESUMO

BACKGROUND: Cerebrospinal fluid (CSF) used in immunoglobulin gamma (IgG) index testing and oligoclonal bands (OCBs) are common laboratory tests used in the diagnosis of multiple sclerosis. The measurement of CSF free light chains (FLC) could pose as an alternative to the labor-intensive isoelectric-focusing (IEF) gels used for OCBs. METHODS: A total of 325 residual paired CSF and serum specimens were obtained after physician-ordered OCB IEF testing. CSF kappa (cKFLC) and lambda FLC (cLFLC), albumin and total IgG were measured. Calculations were performed based on combinations of analytes: CSF sum of kappa and lambda ([cKFLC+cLFLC]), kappa-index (K-index) ([cKFLC/sKFLC]/[CSF albumin/serum albumin]), kappa intrathecal fraction (KFLCIF) {([cKFLC/sKFLC]-[0.9358×CSF albumin/serum albumin]^[0.6687×sKFLC]/cKFLC)} and IgG-index ([CSF IgG/CSF albumin]/[serum IgG/serum albumin]). RESULTS: Patients were categorized as: demyelination (n=67), autoimmunity (n=53), non-inflammatory (n=50), inflammation (n=38), degeneration (n=28), peripheral neuropathy (n=24), infection (n=13), cancer (n=11), neuromyelitis optica (n=10) and others (n=31). cKFLC measurement used alone at a cutoff of 0.0611 mg/dL showed >90% agreement to OCBs, similar or better performance than all other calculations, reducing the number of analytes and variables. When cases of demyelinating disease were reviewed, cKFLC measurements showed 86% clinical sensitivity/77% specificity. CONCLUSIONS: cKFLC alone demonstrates comparable performance to OCBs along with increased sensitivity for demyelinating diseases. Replacing OCB with cKFLC would alleviate the need for serum and CSF IgG and albumin and calculated conversions. cKFLC can overcome challenges associated with performance, interpretation, and cost of traditional OCBs, reducing costs and maintaining sensitivity and specificity supporting MS diagnosis.


Assuntos
Cadeias kappa de Imunoglobulina/líquido cefalorraquidiano , Cadeias lambda de Imunoglobulina/líquido cefalorraquidiano , Esclerose Múltipla/diagnóstico , Bandas Oligoclonais/líquido cefalorraquidiano , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Biomarcadores/líquido cefalorraquidiano , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Cadeias kappa de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/sangue , Lactente , Masculino , Pessoa de Meia-Idade , Nefelometria e Turbidimetria , Sensibilidade e Especificidade , Adulto Jovem
12.
Appl Microbiol Biotechnol ; 102(4): 1923-1931, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29349494

RESUMO

Numerous prokaryotes accumulate polyhydroxyalkanoates (PHA) in the form of intracellular granules. The primary function of PHA is the storage of carbon and energy. Nevertheless, there are numerous reports that the presence of PHA granules in microbial cells enhances their stress resistance and fitness when exposed to various stress factors. In this work, we studied the protective mechanism of PHA granules against UV irradiation employing Cupriavidus necator as a model bacterial strain. The PHA-accumulating wild type strain showed substantially higher UV radiation resistance than the PHA non-accumulating mutant. Furthermore, the differences in UV-Vis radiation interactions with both cell types were studied using various spectroscopic approaches (turbidimetry, absorption spectroscopy, and nephelometry). Our results clearly demonstrate that intracellular PHA granules efficiently scatter UV radiation, which provides a substantial UV-protective effect for bacterial cells and, moreover, decreases the intracellular level of reactive oxygen species in UV-challenged cells. The protective properties of the PHA granules are enhanced by the fact that granules specifically bind to DNA, which in turn provides shield-like protection of DNA as the most UV-sensitive molecule. To conclude, the UV-protective action of PHA granules adds considerable value to their primary storage function, which can be beneficial in numerous environments.


Assuntos
Cupriavidus necator/metabolismo , Cupriavidus necator/efeitos da radiação , Poli-Hidroxialcanoatos/metabolismo , Raios Ultravioleta , Cupriavidus necator/química , DNA Bacteriano/metabolismo , DNA Bacteriano/efeitos da radiação , Viabilidade Microbiana/efeitos da radiação , Espécies Reativas de Oxigênio/análise
13.
Mol Pharm ; 14(3): 580-592, 2017 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-27936778

RESUMO

Lipid-based drug formulations can greatly enhance the bioavailability of poorly water-soluble drugs. Following the oral administration of formulations containing tri- or diglycerides, the digestive processes occurring within the gastrointestinal (GI) tract hydrolyze the glycerides to mixtures of free fatty acids and monoglycerides that are, in turn, solubilized by bile. The behavior of drugs within the resulting colloidal mixtures is currently not well characterized. This work presents matched in vitro experimental and molecular dynamics (MD) theoretical models of the GI microenvironment containing a digested triglyceride-based (Type I) drug formulation. Both the experimental and theoretical models consist of molecular species representing bile (glycodeoxycholic acid), digested triglyceride (1:2 glyceryl-1-monooleate and oleic acid), and water. We have characterized the phase behavior of the physical system using nephelometry, dynamic light scattering, and polarizing light microscopy and compared these measurements to phase behavior observed in multiple MD simulations. Using this model microenvironment, we have investigated the dissolution of the poorly water-soluble drug danazol experimentally using LC-MS and theoretically by MD simulation. The results show how the formulation lipids alter the environment of the GI tract and improve the solubility of danazol. The MD simulations successfully reproduce the experimental results showing the utility of MD in modeling the fate of drugs after digestion of lipid-based formulations within the intestinal lumen.


Assuntos
Danazol/química , Trato Gastrointestinal/química , Monossacarídeos/química , Oligopeptídeos/química , Administração Oral , Bile/química , Disponibilidade Biológica , Química Farmacêutica/métodos , Simulação por Computador , Digestão/fisiologia , Simulação de Dinâmica Molecular , Solubilidade , Triglicerídeos/química , Água/química
14.
Mol Pharm ; 14(11): 3684-3697, 2017 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-28980815

RESUMO

In this study, we use molecular dynamics (MD) and experimental techniques (nephelometry and dynamic light scattering) to investigate the influence of cholesterol content and pH on the colloidal structures that form in the gastrointestinal (GI) tract upon lipid digestion. We demonstrate that the ionization state of the molecular species is a primary driver for the self-assembly of aggregates formed by model bile and therefore should be considered when performing in silico modeling of colloidal drug delivery systems. Additionally, the incorporation of physiological concentrations of cholesterol within the model systems does not affect size, number, shape, or dynamics of the aggregates to a significant degree. The MD data shows a reduction in aggregate size with increasing pH, a preference for glycodeoxycholate (GDX) to occupy the aggregate surface, and that the mixed micellar aggregates are oblate spheroids (disc-like). The results obtained assist in understanding the process by which pH and cholesterol influence self-assembly of mixed micelles within the GI tract. The MD approach provides a platform for investigation of interactions of drugs and formulation excipients with the endogenous contents of the GI tract.


Assuntos
Colesterol/química , Coloides/química , Micelas , Animais , Bile/química , Humanos , Concentração de Íons de Hidrogênio , Simulação de Dinâmica Molecular , Ácido Oleico/química , Fosfolipídeos/química
15.
J Clin Immunol ; 35(6): 573-82, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26275445

RESUMO

PURPOSE: To develop an assay to quantify serum immunoglobulin (IgG, IgM, IgA) levels using dried blood spots (DBS) obtained on collection cards to be used as a tool for targeted screening for hypogammaglobulinemia. METHODS: DBS samples, along with simultaneous serum samples, were collected from 107 healthy individuals (11 months to 57 years of age). After eluting proteins from DBS, IgG, IgM, and IgA were quantified by an enzyme-linked immunosorbent assay (ELISA). The Ig-DBS assay was validated through calibration curve performance, intra- and inter-assay precision, accuracy, specificity, selectivity, and linearity. The ELISA measurements were compared with serum Ig levels obtained using a standard nephelometry assay on serum samples collected simultaneously with the DBS samples and the results of the two assays were correlated. The stability of IgG, IgM, and IgA in the DBS was tested at room temperature, 36° to 38 °C, 2 to 8 °C, and -25 to -40 °C, from 4 to 14 days. RESULTS: The Ig-DBS assay demonstrated precision, accuracy, specificity, selectivity, and linearity. Using the identified correlation coefficients of 0.834 for IgG, 0.789 for IgM, and 0.918 for IgA, the standard nephelometry-based normal reference ranges for all 3 serum Ig isotypes could be used with the Ig-DBS assay in individuals ≥16 years of age. The DBS samples were stable for 14 days at room temperature in a closed polyethylene bag. CONCLUSIONS: The Ig-DBS assay is both sensitive and accurate for quantification of serum immunoglobulins. Samples are sufficiently stable at ambient temperature to allow for convenient shipping and analysis at a centralized laboratory. This assay therefore presents a new option for screening patients ≥16 years of age for hypogammaglobulinemia in any setting.


Assuntos
Agamaglobulinemia/diagnóstico , Teste em Amostras de Sangue Seco/métodos , Programas de Rastreamento/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina A/sangue , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Lactente , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
16.
Scand J Clin Lab Invest ; 74(7): 575-81, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25007050

RESUMO

BACKGROUND: Antigen excess causing a falsely low concentration result may occur when measuring serum free immunoglobulin light chains (SFLC). Automated antigen excess detection methods are available only with some analyzers. We have now developed and verified such a method. METHODS: Residuals of sera with known SFLC-κ and -λ concentrations were analyzed using Binding Site reagents and methods adapted to the Roche Cobas® c.501 analyzer. RESULTS: We analyzed 117 sera for SFLC-κ and -λ and examined how the absorbance increased with time during the 7 minutes of reaction (absorbance reading points 12-70). From this an antigen excess alarm factor (ratio of absorbance increases between reading points 68-60 and 20-12, multiplied by 100) was defined. Upon our request, Roche added to our two SFLC assays a program which calculated this antigen excess alarm factor and triggered an alarm when the factor was below a defined value. We verified this antigen excess alarm function by analyzing serum from 325 persons of whom 143 were multiple myeloma patients. All samples with a known concentration above 30 mg/L triggered either an antigen excess alarm, an 'above test' alarm or both. Also, all samples above 200 mg/L (SFLC-λ) and 300 mg/L (SFLC-κ) triggered the antigen excess alarm and all but one triggered the above test alarm. CONCLUSIONS: The antigen excess alarm function presented here detected all known antigen excess samples at no increased time of analysis, a reduced workload and reduced reagent cost.


Assuntos
Antígenos/sangue , Análise Química do Sangue/métodos , Cadeias kappa de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/sangue , Humanos , Sensibilidade e Especificidade
17.
J Immunol Methods ; 532: 113725, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38997101

RESUMO

Interest in measuring immunoglobulin G Subclasses (IgG Subclasses) is increasing as more information is gathered and understanding regarding conditions associated with deficiencies of each IgG Subclass grows. Different methodologies are available for the measurement of IgG Subclasses, but their specificities vary. As a result, laboratories choose the methodology that better suits their routine, but which may not necessarily align with the needs of their population. In addition, the lack of standardization for the quantification of IgG Subclasses causes diagnostic gaps when comparing results provided by different methodologies. Thus, the purpose of our research is to compare the analytical performance of The Binding Site's (TBS) Optilite® human Immunoglobulin G (IgG) and IgG Subclasses Immunoturbidimetry assay, with the Nephelometry method routinely used in our clinical laboratory, Siemens BNII®. Our results show that the Immunoturbidimetry assay appears to be the most reliable to evaluate IgG Subclasses: the sum of IgG Subclasses and Total IgG correlate better than by Nephelometry. Although these methodologies share a similar principle, the comparison of results appears to be compromised. Therefore, prior to switching methodologies, further studies should be conducted to assess which methodology could be better applied to specific populations. It is also essential to standardise IgG Subclasses assays to reduce discrepancies that arise from comparing results.


Assuntos
Imunoglobulina G , Imunoturbidimetria , Nefelometria e Turbidimetria , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/classificação , Imunoglobulina G/imunologia , Nefelometria e Turbidimetria/métodos , Imunoturbidimetria/métodos , Reprodutibilidade dos Testes , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Idoso
18.
J Biophotonics ; 17(1): e202300234, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37795552

RESUMO

Cell cultures are widely used in scientific research, biomedicine, and industry. When culturing, it is important to maintain certain conditions, including the concentration of cells. Monitoring of the culture growth and cell counting is an urgent task for the optimization of technological processes. Most existing methods require sampling from a culture flask. This procedure is time-consuming and associated with the risks of contamination. We present a device able to monitor the growth of cells number in a suspension noninvasively. The device uses a laser beam that pass through the culture flask and measures the intensity of scattered light as a function of coordinate along the beam. This optical scheme allows one to obtain accurate results for both high- and low-scattering samples. We constructed the wireless portable prototype for monitoring of cell culture growth directly in the incubator and demonstrated the applicability of the device for Jurkat cells and Escherichia coli bacteria.


Assuntos
Técnicas de Cultura de Células , Luz , Humanos , Técnicas de Cultura de Células/métodos , Bactérias
19.
Methods Mol Biol ; 2750: 123-133, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38108973

RESUMO

Most clinical laboratories quantify alpha-1 antitrypsin using either nephelometry or turbidimetry techniques because they are commercially available, amenable to automation, and precise. Both methods are based on light scatter. The foundation of both techniques is based on incubation of the specimen with anti-AAT polyclonal antibody solution, a polymer matrix between endogenous AAT and the reagent antibodies forms, leading to production of light-scattering large particles. Although these two terms are sometimes used synonymously, technically speaking they are not.Nephelometry measures the amount of turbidity or cloudiness of a solution by directly quantifying the intensity of the light scattered by insoluble particles in the sample. Therefore, this technique measures the light that passes through the sample, with the detector being placed at an angle from the sample. Turbidimetry is the process of measuring the loss of intensity of the light transmitted linearly through a sample caused by the scattering effect of insoluble particles. The decrease in light transmission is measured compared to a reference, and the absorbed light is quantified.Beyond specific technical differences between both techniques, there are two major differences between the two procedures that may influence the results. First, the concentration of the sample and the resulting intensity of scattered light relative to the intensity of the light source is one major factor. Second, the size of the scattering particles is also a key differentiating factor. This chapter describes the technical requirements, the different protocols, and the clinical applicability of these two techniques in the diagnosis of alpha-1 antitrypsin deficiency.


Assuntos
Deficiência de alfa 1-Antitripsina , Humanos , Deficiência de alfa 1-Antitripsina/diagnóstico , Nefelometria e Turbidimetria , Anticorpos , Automação , Laboratórios Clínicos
20.
Immunol Res ; 71(6): 883-886, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37322352

RESUMO

Rheumatoid factors (RFs) are useful for diagnosis and classification of rheumatoid arthritis (RA). Nephelometric and turbidimetric techniques, which detect total RF but do not reveal the antibody isotype, are common diagnostic methods in clinical routine. Given the recent development of isotype-specific immunoassays, the detection of IgG, IgM, and IgA RFs represents an interesting challenge. The aim of the study was to evaluate whether specific RF tests performed as a second step after traditional nephelometry could help differentiating RA from other RF-positive diseases. We tested 117 consecutive serum samples that were RF-positive at nephelometry (BNII nephelometric analyzer, Siemens) for IgA, IgG, and IgM RF isotypes by a fluoroimmunoenzymatic assay (FEIA) on the Phadia 250 instrument (ThermoFisher). Fifty-five subjects had RA and 62 presented non-RA diagnoses. Eighteen sera (15.4%) were positive only by nephelometry, two were positive only for IgA RF, and the remaining 97 sera were all positive for IgM RF isotype (with or without IgG and IgA RF). Positive findings did not correlate with RA or non-RA diagnosis. Spearman rho correlation coefficient between nephelometric total RF and IgM isotype was moderate (0.657), and weak between total RF and IgA (0.396) and IgG (0.360) isotypes. Despite its low specificity, measurement of total RF by nephelometry still seems to be the method that performs best. As IgM, IgA, and IgG RF isotypes showed only a moderate correlation with total RF measurement, their diagnostic use as a second level test remains controversial.


Assuntos
Artrite Reumatoide , Fator Reumatoide , Humanos , Imunoglobulina G , Imunoglobulina A , Imunoglobulina M , Ensaio de Imunoadsorção Enzimática/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa