RESUMO
The California quail (Callipepla californica) is an iconic native bird of scrub and oak woodlands in California and the Baja Peninsula of Mexico. Here, we report a draft reference assembly for the species generated from PacBio HiFi long read and Omni-C chromatin-proximity sequencing data as part of the California Conservation Genomics Project (CCGP). Sequenced reads were assembled into 321 scaffolds totaling 1.08 Gb in length. Assembly metrics indicate a highly contiguous and complete assembly with a contig N50 of 5.5 Mb, scaffold N50 of 19.4 Mb, and BUSCO completeness score of 96.5%. Transposable elements (TEs) occupy 16.5% of the genome, more than previous Odontophoridae quail assemblies but in line with estimates of TE content for recent long-read assemblies of chicken and Peking duck. Together these metrics indicate that the present assembly is more complete than prior reference assemblies generated for Odontophoridae quail. This reference will serve as an essential resource for studies on local adaptation, phylogeography, and conservation genetics in this species of significant biological and recreational interest.
Assuntos
Genômica , Codorniz , Animais , Codorniz/genética , Cromossomos , Elementos de DNA Transponíveis , CaliforniaRESUMO
OBJECTIVE: To determine intraocular pressure (IOP) estimates using rebound tonometry in juvenile northern bobwhite quails. ANIMALS STUDIED: Eighteen, 28-day-old, wild caught, captive raised, northern bobwhite quails. PROCEDURES: Birds were manually restrained in sternal recumbency with two fingers placed below the head, applying minimal pressure. Following detailed ophthalmic examination by a board-certified veterinary ophthalmologist, IOP was obtained via rebound tonometry using the Tonovet "P" setting for undefined species in animals without obvious ocular pathology. IOPs were estimated three times on each eye. The mean result of the three estimates was recorded for further analysis. Only readings with low or no reported error were recorded. RESULTS: No difference was detected between the eyes; therefore, a reference interval was calculated using both eyes. The overall IOP (n = 36 eyes) was 5.6 ± 1.2 mmHg (mean ± SD), the median was 6 mmHg, and the range was 2-7 mmHg. The 95% reference interval was 2.2-7.6 mmHg. All quails were ultimately released with no clinically appreciable abnormalities. CONCLUSIONS: This study provides information on normal IOP values for juvenile northern bobwhite quails, which can be used to evaluate the ocular health of this species. Future studies with a larger number of animals are needed, as well as validation of the rebound tonometry method using direct manometry.