Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Mali Med ; 35(1): 6-10, 2020.
Artigo em Francês | MEDLINE | ID: mdl-37978762

RESUMO

INTRODUCTION: The objective of this study was to determine the incidence of the operating site infection, precise the etiologies and identify the risk factors. PATIENTS AND METHOD: This was a prospective study conducted at the department of orthopedics and traumatology at the hospital of Sikasso. The study was conducted from January 2016 to December 2018. The infection criteria were those of CDC from Atlanta. RESULT: This study was conducted on 140 patients including 105 men and 35 women with an average age of 40, 1 years old (3 and 88 years old). We have made 150 interventions including 131 osteosynthesis, 14 arthroplasties and 5 corrective osteotomies. The global incidence of the operating site infection was of 19, 3% with a 13, 4% incidence in surgery class I, 21, 4% in the class II, 26, 5% in the class III and 50% in the class IV. . It was superficial in 18 cases (62, 1%) and deep in 11 cases (37, 9%). The average post-surgery hospitalization duration was 13 days (5 and 70 days in extreme cases). The isolated germs were Staphylococcus aureus in 6 cases (37,5 %), Pseudomonas aeruginosa in 3 cases (18,7 %), Enterobacter cloacae in 3 cases (18,7%), Escherichia Coli in 2 cases (12,5 %,), Klebsiellapneumoniae in 1 case (6,3%) and Proteus mirabilis in 1 case (6,3%). They were 100% sensible to imipramine. 90% of the cases were resisting to ampicillin and penicillin G. CONCLUSION: The incidence of the ISO in our department was high. The risk factors of Operating Sites Infections were: hospitalization duration beyond 2 days, ASA Score over 2 days long, the surgical intervention class and the operation duration higher than 3 hours.


INTRODUCTION: Le but de cette étude était de déterminer l'incidence de l'infection du site opératoire, de préciser les étiologies et d'identifier les facteurs de risque. PATIENTS ET MÉTHODE: Il s'agissait d'une étude prospective réalisée dans le service de chirurgie orthopédique et traumatologique de l'hôpital de Sikasso. L'étude s'est déroulée de Janvier 2016 à décembre 2018. Les critères d'infection ont été ceux du CDC d'Atlanta. RÉSULTATS: Cette étude concernait 140 patients dont 105 hommes et 35 femmes d'âge moyen de 40,1 ans (extrêmes : 3 et 88 ans). Nous avions réalisé 150 interventions dont 131 ostéosynthèses, 14 arthroplasties et 5 ostéotomies de correction. L'incidence globale de l'infection du site opératoire était de 19,3% avec une incidence 13,4% dans la classe de chirurgie I, 21,4% dans la classe II, 26,5% dans la classe III et 50% dans la classe IV. Elle était superficielle dans 18 cas (62,1%) et profonde dans 11 cas (37,9%). La durée moyenne d'hospitalisation post-opératoire était de 13 jours (extrêmes 5 et 70 jours). Les germes isolés étaient le Staphylococcus aureus 6 cas (37,5 %) le Pseudomonas aeruginosa 3 cas (18,7 %), l'Enterobacter cloaca e3 cas (18,7%),l' Escherichia Coli2 cas(12,5 %,), le Klebsiella pneumoniae 1cas (6,3%)et le Protéus mirabilis 1 cas (6,3%). Ils étaient sensibles à l'imipenem dans 100 %. Ils étaient résistants à l'ampicilline, à l'amoxicilline et pénicilline G dans 90% des cas. CONCLUSION: L'incidence des ISO dansnotre service était élevée. Les facteurs de risques des ISO que nous avions identifiés ont été la durée d'hospitalisation supérieure à deux jours, le Score ASA supérieur à 2, la classe de l'intervention chirurgicale et la durée opératoire supérieure à 3 heures.

2.
Rev. gerenc. políticas salud ; 13(27): 266-273, ilus, tab
Artigo em Espanhol | LILACS | ID: lil-751741

RESUMO

Objetivo: evaluar la calidad del proceso de desinfección, medido en unidades relativas de luz (URL) en superficies ambientales de salas de cirugía, instrumentos reutilizables y de reuso mediante el equipo luminómetro 3M Clean Trace. Materiales: con un punto de corte en 250 URL, para definir adecuada calidad de la desinfección, se evaluó una muestra por conveniencia de 39 elementos: seis críticos de reuso, seis superficies ambientales y veintisiete de reutilización de difícil limpieza. Resultados: se encontró mala calidad en la mayoría de elementos evaluados. El gancho monopolar (reuso), la cánula de Frazzier (reutilización) y la mesa de medicamentos (superficie ambiental) fueron los elementos con niveles más elevados en cada grupo. Conclusiones: es necesario mejorar la calidad de limpieza y desinfección en salas de cirugía; el lu-minómetro demostró ser un instrumento útil en el control de calidad de este proceso; se requieren estudios adicionales para proponer puntos de corte más apropiados.


Objective: To assess the quality of the disinfection process, measured in relative light units (URL) on environmental surfaces in operating rooms, reusable and disposable instruments through the luminometer equipment 3M Clean Trace. Materials: With a cut-off point on 250 URL to define the adequate quality of disinfection, we evaluated a convenience sample of 39 elements, six disposable instruments of critical importance, six environmental surfaces and twenty-seven reusable that are difficult to clean. Results: Bad quality was found on most of the evaluated elements. The monopolar hook (disposable), the Frazzier cannula (reusable) and the medicine counter (environmental surface) were the elements with the highest levels in each group. Conclusions: It is necessary to improve the quality of cleaning and disinfection in operating rooms. The luminometer proved to be a useful instrument in the quality control of this process. Additional studies are required to propose more appropriate cut-off points.


Objetivo: avaliar a qualidade do processo de desinfecáo, medido em unidades relativas de luz (URL), em superficies ambientais de salas de cirurgia, instrumentos reutilizáveis e de reuso mediante a equipe luminómetro 3M Clean Trace. Materiais: com um ponto de corte em 250 URL, para definir adequada qualidade da desinfecáo, foi avaliada amostra por conveniencia de 39 elementos: seis críticos de reuso, sies superficies ambientais e vinte e sete de reutilizacáo de difícil limpeza. Resultados: Encontrou-se má qualidade na maioria de elementos avaliados. O gancho monopolar (reuso), a cánula de Frazzier (reutilizacao) e a mesa de medicamentos (superficie ambiental) foram os elementos com níveis mais elevados em cada grupo. Conclusoes: é preciso melhorar a qualidade de limpa e desinfeção em salas de cirurgia; o luminómetro demonstrou ser instrumento útil no controle de qualidade deste processo; requerem-se estudos adicionais para propor pontos de corte mais apropriados.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa