1.
Br J Neurosurg ; : 1-3, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34818116

RESUMO

Thoracic disc herniation (TDH) is a rare occurrence comprising of only 0.25-0.75% of all herniated discs in any region. Limitations in direct visualization remains a surgical challenge for complete and safe resection of TDH. In this case report, we describe the use of a 3D intraoperative imaging system (O-arm system TM) coupled with percutaneous pedicle markers placed under fluoroscopic guidance to circumvent the current limitations in visualisation for a patient with a giant calcified TDH using an anterolateral approach. There was an improvement in overall visualisation and ease of procedure, leading to a successful surgery. Post-op, there was a significant improvement in the motor power of the patient.

2.
Spine Deform ; 8(3): 405-411, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32096141

RESUMO

STUDY DESIGN: Quality improvement evaluation with retrospective analysis. OBJECTIVES: To compare a technique to place pedicle screws (PS) using a novel detachable pedicle marker and probe (DPMP) and pulsed fluoroscopy (PF) vs. conventional technique utilizing PF with standard instruments (SI) and O-arm. Spinal fusion with pedicle screw instrumentation (PSI) is the mainstay in treatment of spinal deformities. Reports suggest that CT navigated (O-arm) PS placement is more accurate than fluoroscopy. However, these studies have not considered the increased radiation exposure associated with CT. METHODS: Thirty-six patients with spinal deformity had PSI using PF and DPMPs. Accuracy of PS placement and radiation data from 14 dosimeters placed on the patient and around the operating room was analyzed. Results were compared to published data. RESULTS: Mean fluoroscopic time was 13.4 s (range 6.0-32.4), and the mean cumulative dose was 3.1 mGy (range 0.2-16.4). Median estimated effective dose to the patient was 0.22 mSv (range 0.0-0.7). The effective dose of radiation was reduced by 80% (0.22 mSv vs. 1.11 mSv) compared to low-dose O-arm. The surgical team did not receive any detectable radiation. The seconds of PF used to assist and confirm placement of PSs was reduced to 1.2 s/level compared to previous reports of 4.49 s/level using SIs. DPMPs reduced fluoroscopy to 0.84 s/PS compared to 7.36 s/PS using SIs to assist and confirm PS placement. PSs were accurately placed in 561 of 576 (97.4%), which is comparable to O-arm and fluoroscopy with SIs. CONCLUSIONS: PS placement using PF and DPMPs to assist and confirm PS placement lowers radiation exposure to the patient and surgical team without compromising accuracy compared to O-arm and fluoroscopy with SIs. LEVEL OF EVIDENCE: Therapeutic, Level IV (Retrospective case series, historical control).


Assuntos
Fluoroscopia/métodos , Parafusos Pediculares , Exposição à Radiação/prevenção & controle , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Melhoria de Qualidade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/efeitos adversos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa