Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Biol Chem ; 299(3): 102936, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36702253

RESUMO

Staphylococcus aureus and Staphylococcus epidermidis are frequently associated with medical device infections that involve establishment of a bacterial biofilm on the device surface. Staphylococcal surface proteins Aap, SasG, and Pls are members of the Periscope Protein class and have been implicated in biofilm formation and host colonization; they comprise a repetitive region ("B region") and an N-terminal host colonization domain within the "A region," predicted to be a lectin domain. Repetitive E-G5 domains (as found in Aap, SasG, and Pls) form elongated "stalks" that would vary in length with repeat number, resulting in projection of the N-terminal A domain variable distances from the bacterial cell surface. Here, we present the structures of the lectin domains within A regions of SasG, Aap, and Pls and a structure of the Aap lectin domain attached to contiguous E-G5 repeats, suggesting the lectin domains will sit at the tip of the variable length rod. We demonstrate that these isolated domains (Aap, SasG) are sufficient to bind to human host desquamated nasal epithelial cells. Previously, proteolytic cleavage or a deletion within the A domain had been reported to induce biofilm formation; the structures suggest a potential link between these observations. Intriguingly, while the Aap, SasG, and Pls lectin domains bind a metal ion, they lack the nonproline cis peptide bond thought to be key for carbohydrate binding by the lectin fold. This suggestion of noncanonical ligand binding should be a key consideration when investigating the host cell interactions of these bacterial surface proteins.


Assuntos
Proteínas de Bactérias , Modelos Moleculares , Domínios Proteicos , Staphylococcus aureus , Humanos , Adesinas Bacterianas/genética , Adesinas Bacterianas/metabolismo , Proteínas de Bactérias/química , Proteínas de Bactérias/metabolismo , Lectinas/química , Lectinas/metabolismo , Infecções Estafilocócicas/microbiologia , Staphylococcus epidermidis/química , Staphylococcus epidermidis/genética , Staphylococcus epidermidis/metabolismo , Domínios Proteicos/fisiologia , Estrutura Terciária de Proteína , Ligação Proteica , Staphylococcus aureus/química , Staphylococcus aureus/genética , Staphylococcus aureus/metabolismo , Proteínas Recombinantes/química , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Escherichia coli , Células Epiteliais/microbiologia
2.
Sensors (Basel) ; 24(7)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38610429

RESUMO

Sequentially timed all-optical mapping photography is one of the main emerging ultra-fast detection technologies that can be widely applicable to ultra-fast detection at the picosecond level in fields such as materials and life sciences. We propose a new optical structure for an all-optical spatial mapping module that can control the optical field of two-dimensional imaging while improving spectral resolution and detector sensor utilization. The model of optical parameters based on geometrical optics theory for the given structure has been established, and the theoretical analysis of the inter-frame energy crosstalk caused by incident beam spot width, chromatic aberration, and main errors of the periscope array has been conducted. The optical design of the two-dimensional (2D) all-optical spatial mapping module was finally completed using ZEMAX OpticStudio 2018 software. The results show that our optical module can realize targets of 16 frames and 1.25 nm spectral resolution.

3.
Catheter Cardiovasc Interv ; 101(5): 888-891, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36883951

RESUMO

Arterial pseudoaneurysms represent an uncommon complication of acute pancreatic inflammation or chronic pancreatitis. We describe a contained rupture of a suprarenal abdominal aortic pseudoaneurysm. An aorto-uni-iliac stent-graft was adopted as the aortic main body and was combined with two chimneys and two periscope stents for celiac/superior mesenteric artery and renal arteries, respectively. The procedure was complicated by the entrapment of the celiac sheath into the barbs of the aortic stent-graft and the attempts to remove the sheath resulted in an upward migration of the stent-grafts. A bail-out endovascular procedure was used to reline the stent-grafts and the pseudoaneurysmal sac was embolized with coils.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Pancreatite , Humanos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Resultado do Tratamento , Stents , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Desenho de Prótese , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia
4.
J Vasc Surg ; 76(2): 311-317, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35276255

RESUMO

OBJECTIVE: Chimneys and periscopes are often used to treat pararenal or thoracoabdominal aneurysms de novo or after failed open or endovascular repair. We sought to describe our institutional experience, given their limited success and questionable long-term outcomes. METHODS: We retrospectively reviewed the electronic records for patients treated with chimneys/periscopes from 1997 through 2020. Baseline characteristics, procedural details, periprocedural complications, reinterventions, and midterm outcomes were collected. RESULTS: Fifty-eight patients (86 vessels) were treated; the median follow-up was 32 months (range, 0.03-104 months). There were 36% (n = 21) juxta-renal, 2% (n = 1) para-visceral, and 21% (n = 12) thoracoabdominal aneurysms, and 41% (n = 24) had pararenal failure of prior endovascular aneurysm repair (n = 17) or open repair (n = 7). Stent configuration for the majority of the 86 vessels (n = 80; 93%) treated were chimney configuration (n = 6 periscopes; 7%). The most common stent graft utilized was Viabahn, and 8.1% (n = 7) were reinforced with a bare metal stent. Although the majority of the cases were elective, 36.2% (n = 21) of the cases were urgent/emergent. At the conclusion of the initial procedure, 16 of 58 patients had an endoleak (gutter, 50% [8/16]; type Ia, 25% [4/16]; and type II, 25% [4/16]). On follow-up, 14 of 58 patients developed one or more endoleaks, with the most common endoleaks being a gutter endoleak (35% [7/20]). Other endoleaks observed included 30% (6/20) type III, 15% (3/20) type Ia, 15% (3/20) type Ib, and 5% (1/20) type II. Eleven of 58 patients underwent interventions for one or more endoleak (gutter, 33% [5/15]; type Ib, 20% [3/15]; type II, 7% [1/15]; and type III, 40% [6/15]). Twelve of 58 patients returned to the operating room for one or more procedures during the index hospitalization (five laparotomies, three dialysis access, three acute limb ischemia, and four chimney/periscope interventions). Ten of 58 patients underwent angioplasty/stenting for chimney/periscope compression or occlusion during the follow-up period. Survival was 61.3% at 1 year by Kaplan-Meier analysis (75% for elective, 37% for urgent/emergent) (aneurysm-related death, 22%). Cox hazard modeling showed that aneurysm diameter (hazard ratio, 1.03; 95% confidence interval, 1.004-1.05; P = .02) and urgent/emergent interventions (hazard ratio, 3.6; 95% confidence interval, 1.33-9.74; P = .01) were predictors of mortality. CONCLUSIONS: Endovascular repair of aortic aneurysms with chimneys/periscopes is associated with poor outcomes, including limited technical success and aneurysm exclusion, as well as high morbidity and mortality, with a high rate of reinterventions both in the immediate postoperative period and on follow-up. They should be used only when other surgical or endovascular options are not possible.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/terapia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
5.
Vascular ; 30(6): 1058-1068, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35199611

RESUMO

OBJECTIVE: Recent guidelines recognize the role of chimney endovascular aneurysm repair (ChEVAR) in the treatment of complex aortic disorders. The optimal configuration and number of visceral vessels that can be incorporated is still controversial. We aim to review outcomes from a multi-institutional decade-long experience with ChEVAR. METHODS: Patients undergoing ChEVAR with multiple (≥2) chimney branches were selected from a prospectively maintained database at the two academic university hospitals. All patients were poorly suited for fenestrated or branched endograft repair (F/BEVAR) and deemed poor-risk for open surgery. RESULTS: Forty-nine multiple ChEVAR were performed in 44 men and 5 women, with complete outcome data at a mean follow-up of 18 months. Overall, 2 patients died during follow-up (4%) with no aneurysm-related mortality and two ruptures after ChEVAR (4.1%) due to a type Ib endoleak from iliac limb pullout and persistent gutter-flow, both repaired with endovascular means. No stroke or spinal cord ischemia was noted during the follow-up period. Reintervention was undertaken in eight patients (16.3%) with five reinterventions for persistent gutter-flow and four chimney graft-associated. Three-vessel ChEVAR was performed in 16 patients, with two-vessel ChEVAR in 33 patients for a total of 114 chimney branches (mean 2.3 chimneys per patient). There were 21 superior mesenteric artery (SMA), 45 right renal, 46 left renal artery (LRA), and two accessory LRA chimneys placed. Antegrade configuration of chimney branches was chosen in 43 patients (88%). There were no significant differences between three-vessel and two-vessel ChEVAR upon univariate analysis in aneurysm size (65.6 vs 60.5 mm; p = 0.059), iliac diameter (7.3 vs 7.1 mm; p = 0.85), or endograft oversizing (30 vs 32.5%; p = 0.43). Three-vessel ChEVAR was associated with a larger aneurysm neck diameter (28.4 vs 25.0 mm; p = 0.021), shorter native infrarenal neck (0.5 vs 3.37 mm; p = 0.002) as well as longer seal zone (36.33 vs 22.67 mm; p = 0.005) compared with two-vessel ChEVAR. At follow-up, there were no significant differences in gutter area between three-vessel and two-vessel ChEVAR (18.9 vs 15.7 mm3; p = 0.73) nor the rate of persistent gutter-flow (12.5 vs 9.1%; p = 0.71). CONCLUSION: Reintervention to multiple chimney grafts and for persistent gutter-flow is higher compared to single chimneys and demands close surveillance. However, based upon this combined transantlantic experience, we believe multiple ChEVAR provides a reasonable and safe option for complex aortic aneurysm repair when open or custom endografts are not available or indicated based on their Instructions For use, even when triple chimney grafts are required. The optimal configuration for multiple ChEVAR still warrants further study, although theoretical preliminary advantages may exist for a combination of antegrade and retrograde chimneys.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Feminino , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Resultado do Tratamento , Fatores de Risco , Estudos Retrospectivos
6.
Sensors (Basel) ; 21(22)2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34833700

RESUMO

Submarines are considered extremely strategic for any naval army due to their stealth capability. Periscopes are crucial sensors for these vessels, and emerging to the surface or periscope depth is required to identify visual contacts through this device. This maneuver has many procedures and usually has to be fast and agile to avoid exposure. This paper presents and implements a novel architecture for real submarine periscopes developed for future Brazilian naval fleet operations. Our system consists of a probe that is connected to the craft and carries a 360 camera. We project and take the images inside the vessel using traditional VR/XR devices. We also propose and implement an efficient computer vision-based MR technique to estimate and display detected vessels effectively and precisely. The vessel detection model is trained using synthetic images. So, we built and made available a dataset composed of 99,000 images. Finally, we also estimate distances of the classified elements, showing all the information in an AR-based interface. Although the probe is wired-connected, it allows for the vessel to stand in deep positions, reducing its exposure and introducing a new way for submarine maneuvers and operations. We validate our proposal through a user experience experiment using 19 experts in periscope operations.


Assuntos
Realidade Aumentada , Brasil , Interface Usuário-Computador
7.
Vascular ; 28(6): 675-682, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32396495

RESUMO

OBJECTIVES: Open repair is still the first choice for thoraco-abdominal and para-renal aortic aneurysms, but surgical treatment is burdened by significant morbidity and mortality, especially in urgent setting. Endovascular treatment by fenestrated or branched endografts is feasible and safe; but in urgent/emergent settings, custom-made endografts are hardly available in due time, and the repair with standard multibranched devices is still debated in cases with complex anatomy. Parallel grafting, on the other hand, which exploits covered stents to preserve patency of the visceral vessels, has been shown as a valuable option and can be performed in urgency, though some concerns still remain regarding its durability and complications. The purpose of this case series is to review the outcomes of all consecutive cases of complex aortic diseases treated with this technique in emergent/urgent setting. MATERIALS AND METHODS: All cases of endovascular aortic repair of thoraco-abdominal and para-thoraco-abdominal performed in urgency or emergency from 2016 to June 2019 were retrospectively reviewed, recording clinical records, operative technique, primary technical success, and long-term outcomes. Each patient was followed-up by computed tomography angiography three months after the procedure and yearly thereafter. RESULTS: Twenty consecutive patients (median age: 68, range: 47-89, male/female ratio: 16:4) affected by para-thoraco-abdominal (12) or thoraco-abdominal (8) were treated in urgent or emergent setting by chimney and/or periscope technique. A total number of 37 visceral vessels were stented (29 renal arteries, 1 polar artery of the kidney, 3 superior mesenteric arteries, and 4 coeliac trunks). Primary technical success was 100%, with one perioperative death. One patient died on post-operative month III for unrelated cause. Two type II endoleaks were detected at the first post-operative imaging studies and were managed conservatively. One type IB endoleak was treated by endovascular repair with a custom-made endograft (overall re-intervention rate: 5%). Over a median 22 months follow-up (range: 4-40, interquartile range: 12 months), all stentgrafts were patent. CONCLUSION: Parallel graft is a feasible and safe option that should be considered in urgent and emergent treatment of para-thoraco-abdominal and thoraco-abdominal, when fenestrated and branched endografts cannot be used.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Endoleak/etiologia , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Acta Cardiol Sin ; 36(4): 351-359, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32675927

RESUMO

BACKGROUND: Preservation of supra-aortic branches in thoracic endovascular aortic repair plays a role in associated neurological outcomes, and the strategy varies. OBJECTIVES: This study aimed to evaluate the safety and efficacy of a parallel graft technique to reconstruct the aortic arch. METHODS: From August 2014 to July 2018, a total of 25 patients with thoracic aortic pathologies requiring arch reconstruction were included. All patients underwent thoracic aortic endovascular repair (TEVAR) with a zone 1 landing aortic stent graft, a chimney graft to preserve the left common carotid artery, and a periscope graft to preserve the left subclavian artery. The associated outcomes and complications were reported. RESULTS: Eighteen patients presented with aortic dissection, 4 with a thoracic aortic aneurysm, 1 with a penetrating aortic ulcer, 1 with a traumatic aortic injury, and 1 case of re-TEVAR. The technical success rate was 96% (24/25), but the case of immediate failure died of retrograde type A dissection. Over a mean follow-up of 32.33 months, another retrograde type A aortic dissection was detected in 1 month, and a case of early failure (< 1 year) and 3 cases of late failure (> 1 year) whose primary aortic problems recurred were detected. CONCLUSIONS: This study demonstrates a total endovascular approach to preserve supra-aortic branches with a parallel graft technique. However, the dilemma of excessive graft oversizing was disclosed due to the risk of retrograde type A dissections and an unsatisfactory durability in this small series.

9.
Vascular ; 27(2): 204-212, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30522411

RESUMO

BACKGROUND: Whilst the management of blunt traumatic thoracic aortic injury has seen a paradigm shift to an 'endovascular first' approach, the limitations of thoracic endovascular aortic repair remain. An inadequate proximal landing zone limits the use of thoracic aortic stent grafts and in an emergent polytrauma setting, aortic arch debranching via open surgery may not be practical or feasible. A wholly endovascular approach to debranching utilising 'off-the-shelf' stents and parallel graft techniques may represent a possible solution. Hence, we sought to perform a systematic review investigating the use of chimney graft techniques alongside thoracic aortic stenting in blunt traumatic thoracic aortic injury. METHODS: We performed the systematic review in accordance to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Searches were performed on Medline (PubMed), Web of Science and Scopus to identify articles describing the use of chimney grafts in traumatic aortic transection (PROSPERO: CRD42017082549). RESULTS: The systematic search revealed 172 papers, of which 88 duplicates were removed resulting in 84 papers to screen. Based on title, abstract and full text review, six articles were included for final analysis. There were nine patients in total with an average age of 41 (three females, five males, one unspecified), all with significant polytrauma, secondary to the mechanism of injury. A variety of stents were used between centres, with techniques showing a predominance to stenting of the left subclavian artery (77%, n = 7). The technical success rate was 82%, with two (18%) cases of type 1 endoleaks, of which one resolved spontaneously. CONCLUSIONS: Despite the encouraging results, this by no means provides for a firm conclusion given the small sample size. Patients should still be judiciously selected on a case-by-case basis when employing the chimney graft technique. Larger cohort studies are needed to establish these findings.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Traumatismos Torácicos/cirurgia , Lesões do Sistema Vascular/cirurgia , Ferimentos não Penetrantes/cirurgia , Adulto , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/lesões , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Risco , Traumatismos Torácicos/diagnóstico por imagem , Traumatismos Torácicos/mortalidade , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/mortalidade , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/mortalidade
10.
J Endovasc Ther ; 25(4): 492-498, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29911481

RESUMO

PURPOSE: The aim of this retrospective analysis was to evaluate the performance of the chimney (ch) technique in the treatment of type Ia endoleaks after standard endovascular aneurysm repair (EVAR). METHODS: Between January 2008 and December 2014, 517 chEVAR procedures were performed in 13 US and European vascular centers (PERICLES registry). Thirty-nine patients (mean age 76.9±7.1 years; 33 men) were treated for persistent type Ia endoleak and had computed tomography angiography or magnetic resonance angiography follow-up at >1 month. Endurant abdominal stent-grafts were used in the 20 cases. Single chimney graft placement was performed in 18 (46%) patients and multiple in 21 (54%). Overall, 70 visceral vessels were targeted for revascularization. RESULTS: Technical success was achieved in 35 (89.7%) cases; 3 persistent type Ia endoleaks and 1 chimney graft occlusion were detected within the first 30 days. Thirty-day mortality was 2.6%. Two other deaths (not aneurysm related) occurred during a mean follow-up of 21.9 months (0.23-71.3). Primary patency of the chimney grafts was 94.3% at 36 months. In a subgroup analysis comparing Endurant to other stent-grafts, no significant differences were observed regarding persistent endoleak [1/20 (5%) vs 2/19 (11%), p=0.6] or reintervention [1/20 (5%) vs 0/19 (0%)]. CONCLUSION: The present series demonstrates that chEVAR in the treatment of post-EVAR type Ia endoleaks has satisfactory results independent of the abdominal and chimney graft combinations. Midterm results show that chEVAR is an effective method for treating type Ia endoleaks.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
11.
J Endovasc Ther ; 24(6): 779-782, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28882080

RESUMO

PURPOSE: To report endovascular treatment of a symptomatic type V thoracoabdominal aortic aneurysm (TAAA) using the combined techniques of endovascular aneurysm sealing and parallel stent-grafts. CASE REPORT: A 70-year-old man was referred with a symptomatic type V TAAA. The Nellix EndoVascular Aneurysm Sealing (EVAS) System was used in combination with 2 chimney grafts for the celiac artery (CA) and the superior mesenteric artery (SMA); one periscope graft perfused the right renal artery. Completion angiography showed exclusion of the aneurysm and patency of all 3 parallel grafts but occlusion of the left renal artery (LRA) due to unintentional coverage of its ostium by the Nellix endobags. Antegrade catheterization of the LRA failed, requiring implantation of an aortorenal vein bypass. The postoperative course was complicated by acute kidney injury. Imaging at 6 months showed sustained exclusion of the aneurysm, patency of the CA and SMA parallel grafts and left aortorenal bypass but occlusion of the right renal artery periscope graft. Serum creatinine at 6 months was 1.5 mg/dL. CONCLUSION: The combination of EVAS with parallel grafts for preservation of the visceral vessels may be a feasible technique to treat selected TAAAs in the acute setting when other options are not applicable.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Desenho de Prótese , Resultado do Tratamento , Grau de Desobstrução Vascular
12.
J Endovasc Ther ; 24(5): 647-653, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28747077

RESUMO

OVERVIEW: To describe a new endovascular procedure for acute type A aortic dissection (TAAD) repair. METHODS: Between 2013 and 2016, 12 patients (average age 54±9.6 years; 10 men) with acute TAAD (mean EURO score 11.4%±3.2%, range 5-17) and unfit for surgery underwent thoracic endovascular aortic repair (TEVAR) with 2 periscope grafts to preserve blood supply to supra-aortic branches plus bypass grafting as needed. If the ascending aorta was dilated to >40 mm, sternotomy was performed to wrap the ascending aorta and reduce its diameter to accommodate the aortic stent-grafts. RESULTS: All patients were successfully treated. Seven patients required bypass grafting, and most of the patients had periscope grafts to the innominate/right common carotid artery and left common carotid artery; only 3 patients had the left subclavian artery preserved. All patients exhibited good hemodynamics and normal pressures after the procedure. The mean procedure time and blood loss were 4.5±1.0 hours and 217±111.5 mL, respectively. Two patients treated emergently died shortly after surgery from multiorgan failure. The average follow-up duration was 17±14.5 months (range 2-42) in the 10 survivors. The remaining patients recovered and none experienced stent-graft thrombosis, stroke, or peripheral artery embolism during follow-up. CONCLUSION: A procedure that combines sandwich/periscope grafting with TEVAR, wrapping of the aorta, and supra-arch bypass grafting can be used to treat patients with acute TAAD.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Doença Aguda , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Transplantes , Resultado do Tratamento
13.
Eur J Vasc Endovasc Surg ; 54(3): 295-302, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28754428

RESUMO

PURPOSE: Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). METHODS: Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. RESULTS: Forty-one patients (28.05% EuroScore II) with thoraco-abdominal aortic aneurysm (17%), arch aneurysm (39%), descending aneurysm (34%), and aneurysm extending from the arch to the visceral aorta (10%) were included. Fifteen (37%) patients were treated non-electively. Fifty-nine SABs were treated with the CPG technique: one, two, three, and four CPG were employed in 71%, 19%, 5%, and 5% of patients, respectively. The proximal landing was in zone 0 in 49% of patients, zone 1 in 17%, and zone 2 in 34%. Technical success was 95%. Peri-operative complications and neurological events were registered in six (14.6%) patients and there were 5 deaths (12%). At a median follow-up of 21.2 (mean 22, SD 18; range 0-65) months, type I/III endoleaks were registered in three (7%) cases and re-intervention in six (15%) patients. A significant aneurysm sac shrinkage (p<.001) was reported at mean follow-up and no significant aneurysm sac increase (>5 mm). The estimated 2 year survival, freedom from re-intervention, freedom from endoleak, and freedom from branch occlusion were 75%, 77%, 86%, and 96%, respectively. CONCLUSION: The chimney and periscope grafts technique was shown to be safe in aortic aneurysm disease involving the supra aortic branches, even in an emergency setting using off the shelf devices. Mid-term follow-up results in this high risk population are good, but longer follow-up is mandatory before this technique is used in intermediate-risk patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Intervalo Livre de Doença , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
14.
Eur J Vasc Endovasc Surg ; 51(5): 664-73, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26961762

RESUMO

OBJECTIVE: The aim was to report on chimney and periscope grafts (CPGs) and their mid- and longer-term outcomes when they are used to preserve reno-visceral artery (RVA) perfusion in endovascular repair of pararenal (PRAAs) or thoraco-abdominal aortic aneurysm (TAAAs). In addition, factors associated with CPG failure are presented. Limited data exist on the outcomes of CPGs, and mid- and long-term results are generally not reported. METHODS: This was a prospective study in a cohort of 100 patients with PRAA (69) or TAAA (31). A total of 224 (mean 2.24 per patient) RVAs were preserved with 136 (61%) chimney and 88 (39%) periscope grafts. CPGs were constructed mainly using self expandable stent grafts. Patients were followed by clinical examination, CTA (82%), and/or duplex (18%). Data were collected until February 2015. RESULTS: CPG immediate technical success was 99% (222/224 branches). Mean follow up was 29 months (range 0-65; SD 17); 59% patients were followed > 2 years, 30% > 3 years, and 16% > 4 years. Post-operatively, CPG occlusion was observed early (≤30 days) in three (1.3%) branches and during follow up in 10 (4.5%). At 36 and 48 months, the estimated primary patency was 93% and 93%. After corrective percutaneous (10) or surgical (3) re-interventions, the estimated secondary patency was 96% and 96%. Thirty day mortality was 2%; at 36 and 48 months the estimated patient survival was 79%. Significant shrinkage (72 [SD 23] vs. 62 [SD 24] mm; p < .001) was observed, with a substantial reduction (>5 mm) in 55 patients, and sac enlargement in four. Incomplete aneurysm sac sealing was treated successfully by a secondary intervention in 15 patients. CONCLUSIONS: Self expandable CPGs have proved to be a highly successful and durable treatment for RVA preservation up to 5 years. Incomplete CPG expansion, inadequate length, and CPG use in small and diseased target arteries were risk factors for occlusion. These mid- and longer-term results support CPG use to treat PRAAs or TAAAs in patients unfit for open surgery or fenestrated/branched stent grafts.


Assuntos
Aneurisma Aórtico/cirurgia , Enxerto Vascular/métodos , Idoso , Aorta/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Artéria Renal/fisiologia , Estudos Retrospectivos , Fatores de Risco , Falha de Tratamento , Enxerto Vascular/efeitos adversos
15.
J Endovasc Ther ; 22(3): 396-400, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25878021

RESUMO

PURPOSE: To review the literature on pararenal endovascular aneurysm repair (EVAR) to determine the frequency and clinical relevance of chimney graft occlusions. METHODS: A comprehensive search of the English-language literature abstracted in the Medline and the Cochrane Library databases was performed to identify case series involving pararenal aortic pathologies (degenerative aneurysms, penetrating atherosclerotic ulcers, type Ia endoleaks, and para-anastomotic aneurysms) treated with EVAR and chimney grafts; thoracoabdominal, iliac, or aortic arch chimney graft placements were excluded, as were case reports in which the total number of chimney grafts implanted at the reporting center could not be determined. The literature search identified 83 studies regarding chimneys/snorkels for pararenal pathologies published between January 2007 and March 2014. Of these, 7 studies met the inclusion criteria and were included in the analysis. RESULTS: There were 15 (4.5%) occlusions in the overall 334 renovisceral vessels in which chimney grafts were deployed. The mean time to chimney graft occlusion was 3.5 months (range 1-270 days) over a mean follow-up of 1.4 months (range 9-24). The target arteries were the renal artery (n=12) and the superior mesenteric artery (SMA; n=3). Seven patients were asymptomatic, and no description was given in 5 cases. In the other 3 patients, the symptoms were acute renal failure, intestinal ischemia, and malignant hypertension. The treatment strategy included open conversion and iliorenal bypass (n=1), exploratory laparotomy to revascularize the SMA (n=1), hemodialysis (n=1), placement of bare metal stents (n=4), conservative treatment (n=2), and unknown (n=6). One (6.7%) patient died (an occluded SMA). Two patients with renal chimney occlusion suffered from temporary renal function deterioration. CONCLUSION: The present analysis identified a low rate of chimney graft occlusions, which appear to occur generally a few months after placement. Involvement of the renal artery had no severe clinical consequences, while occlusion of the SMA can be associated with life-threatening complications. More detailed information regarding occluded chimney grafts will be needed in future publications to help identify the causes.


Assuntos
Doenças da Aorta/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Oclusão de Enxerto Vascular/etiologia , Stents , Doenças da Aorta/diagnóstico , Doenças da Aorta/mortalidade , Doenças da Aorta/fisiopatologia , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/mortalidade , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/mortalidade , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/terapia , Humanos , Artéria Mesentérica Superior/fisiopatologia , Oclusão Vascular Mesentérica/etiologia , Oclusão Vascular Mesentérica/fisiopatologia , Desenho de Prótese , Obstrução da Artéria Renal/etiologia , Obstrução da Artéria Renal/fisiopatologia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
16.
J Endovasc Ther ; 22(4): 568-74, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25969150

RESUMO

PURPOSE: To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). METHODS: Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2-179). All patients had proximal/distal landing zones precluding any standard endovascular reintervention. Measured outcomes included technical success and perioperative mortality and morbidity. Technical success was defined as a procedure completed as intended, with no secondary procedures within 30 days. Midterm outcomes included survival, CPG patency, endoleaks, and freedom from reintervention. RESULTS: Technical success was 96%; a single patient required an additional procedure to seal a recurrent type Ia endoleak. Intraoperative revascularization of all 55 target vessels (2.3/patient) with CPGs was successful. One (4%) patient died within 30 days. Estimated survival at 12, 24, and 36 months was 83%; estimated CPG patency at the same intervals was 94%. Over a mean follow-up of 23.4±29 months, 6 (25%) reinterventions were performed; of these, 4 were secondary to type I endoleak. Aneurysm diameters reduced from 88.3±26 to 85.5±33 mm (p=0.49) over the mean follow-up. CONCLUSION: The CPG technique is a safe and effective tool for treatment of type I endoleak after previous EVAR. The CPG technique is feasible even in nonelective patients, with excellent outcomes in terms of patency. Close imaging follow-up is warranted to rule out recurrent or de novo endoleaks.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Endoleak/cirurgia , Procedimentos Endovasculares , Idoso , Prótese Vascular , Feminino , Humanos , Masculino , Recidiva , Taxa de Sobrevida , Resultado do Tratamento , Grau de Desobstrução Vascular
17.
Eur J Vasc Endovasc Surg ; 50(6): 722-31, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26371416

RESUMO

BACKGROUND: The chimney graft (CG) technique was introduced to rescue accidentally covered aortic branches during aortic endovascular repair. It extends the sealing zone. There is concern about "gutter" type I endoleak (EL-I) and about the durability of CGs. The aim of the present report was to analyze the rapidly increasing existing data. METHODS: A search was performed (PRISMA criteria) for all studies of visceral and thoracic/arch chimney grafts. Technical and clinical details and outcome were assessed. RESULTS: The present review includes 831 patients who underwent EVAR/TEVAR (endovascular aneurysm repair/thoracic endovascular aneurysm repair) with one or more chimney, periscope, or sandwich grafts. For aortic visceral vessels 517 patients received 911 visceral CGs and 314 patients received 364 arch CGs. Most procedures (81% visceral and 69% arch CGs) were elective. Thirty day mortality was 4% for both groups. The rate of early EL-I was 13% (visceral CGs) and 11% (arch CGs). Most EL-I were handled conservatively (observation: 70% for visceral CG and 45% for arch CG). Early CG patency was high (97-99%) and remained high during follow up (median 17 months). Late (after 30 days) EL-I was reported in nine visceral (2%) and 12 arch (4%) CG cases. Few other late complications were reported, but those losing a kidney at the initial repair seemed to have a high risk of requiring permanent hemodialysis. CONCLUSION: Increasing amounts of data support the benefit of visceral and arch chimney graft techniques. In particular, the low early mortality and complication rates and high long-term patency seem advantageous; however, the majority of cases have been treated electively, and there is a high risk of bias in all studies. Mid- to long-term data suggest few late complications, except in cases where one renal artery was sacrificed. The CG technique is valuable for complex urgent patients and needs further documentation for other patient groups.


Assuntos
Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Doenças da Aorta/diagnóstico , Doenças da Aorta/mortalidade , Doenças da Aorta/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Grau de Desobstrução Vascular
18.
Micromachines (Basel) ; 14(6)2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37374857

RESUMO

The size of the optical zoom system is important in smartphone camera design, especially as it governs the thickness of the smartphone. We present the optical design of a miniaturized 10× periscope zoom lens for smartphones. To achieve the desired level of miniaturization, the conventional zoom lens can be replaced with a periscope zoom lens. In addition to this change in the optical design, the quality of the optical glass, which also affects the performance of the lens, must be considered. With advancements in the optical glass manufacturing process, aspheric lenses are becoming more widely used. In this study, aspheric lenses are incorporated into a design for a 10× optical zoom lens with a lens thickness of less than 6.5 mm and an eight-megapixel image sensor. Furthermore, tolerance analysis is carried out to prove its manufacturability.

20.
Artigo em Inglês | MEDLINE | ID: mdl-35897503

RESUMO

Since the start of the 21st century, the world has not confronted a more serious threat to global public health than the COVID-19 pandemic. While governments initially took radical actions in response to the pandemic to avoid catastrophic collapse of their health care systems, government policies have also had numerous knock-on socioeconomic, political, behavioral and economic effects. Researchers, thus, have a unique opportunity to forward our collective understanding of the modern world and to respond to the emergency situation in a way that optimizes resources and maximizes results. The PERISCOPE project, funded by the European Commission, brings together a large number of research institutions to collect data and carry out research to understand all the impacts of the pandemic, and create predictive models that can be used to optimize intervention strategies and better face possible future health emergencies. One of the main tangible outcomes of this project is the PERISCOPE Atlas: an interactive tool that allows to visualize and analyze COVID-19-related health, economic and sociopolitical data, featuring a WebGIS and several dashboards. This paper describes the first release of the Atlas, listing the data sources used, the main functionalities and the future development.


Assuntos
COVID-19 , COVID-19/epidemiologia , Atenção à Saúde , Saúde Global , Governo , Humanos , Pandemias
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa