Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.703
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Brain ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38990981

RESUMO

Both sleep alterations and epileptiform activity are associated with the accumulation of amyloid-ß and tau pathology and are currently investigated for potential therapeutic interventions in Alzheimer's disease (AD). However, a bidirectional intertwining relation between sleep and neuronal hyperexcitability might modulate the effects of AD pathology on the corresponding associations. To investigate this, we performed multiple day simultaneous foramen ovale (FO) plus scalp EEG and polysomnography (PSG) recordings and acquired 18F-MK6240 tau PET-MR in three patients in the prodromal stage of AD and in two patients with mild and moderate dementia due to AD, respectively. As an eligibility criterion for the present study, subjects either had a history of a recent seizure (n = 2) or subclinical epileptiform activity (SEA) on a previous scalp EEG taken in a research context (n = 3). The 18F-MK6240 standard uptake value ratio (SUVR) and asymmetry index (AI) were calculated in a priori defined volumes of interest (VOIs). Linear mixed effects models were used to study associations between interictal epileptiform discharges (IEDs), PSG parameters and 18F-MK6240 SUVR. Epileptiform activity was bilateral but asymmetrically present on FO electrodes in all patients and ≥ 95% of IEDs were not visible on scalp EEG. In one patient two focal seizures were detected on FO electrodes, both without visual scalp EEG correlate. We observed lateralized periodic discharges, brief potentially ictal rhythmic discharges and lateralized rhythmic delta activity on FO electrodes in four patients. Unlike scalp EEG, intracranial electrodes showed a lateralization of epileptiform activity. Although the amount of IEDs on intracranial electrodes was not associated to the 18F-MK6240 SUVR binding in different VOIs, there was a congruent asymmetry of the 18F-MK6240 binding towards the most epileptic hemisphere for the mesial (P = 0.007) and lateral temporal cortex (P = 0.006). IEDs on intracranial electrodes were most abundant during slow wave sleep (SWS) (92/h) and N2 (81/h), followed by N1 (33/h) and least frequent during wakefulness (17/h) and REM sleep (9/h). The extent of IEDs during sleep was not reflected in the relative time in each sleep stage spent (REM% (P = 0.415), N1% (P = 0.668), N2% (P = 0.442), SWS% (P = 0.988)), and not associated with the arousal index (P = 0.317), apnea-hypopnea index (P = 0.846) or oxygen desaturation index (P = 0.746). Together, our observations suggest a multi-directional interaction between sleep, epileptiform activity and tau pathology in AD.

2.
J Physiol ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38408065

RESUMO

Hypoxia at high altitude facilitates changes in ventilatory control that can lead to nocturnal periodic breathing (nPB). Here, we introduce a placebo-controlled approach to prevent nPB by increasing inspiratory CO2 and used it to assess whether nPB contributes to the adverse effects of hypoxia on sleep architecture. In a randomized, single-blinded, crossover design, 12 men underwent two sojourns (three days/nights each, separated by 4 weeks) in hypobaric hypoxia corresponding to 4000 m altitude, with polysomnography during the first and third night of each sojourn. During all nights, subjects' heads were encompassed by a canopy retaining exhaled CO2 , and CO2 concentration in the canopy (i.e. inspiratory CO2 concentration) was controlled by adjustment of fresh air inflow. Throughout the placebo sojourn inspiratory CO2 was ≤0.2%, whereas throughout the other sojourn it was increased to 1.76% (IQR, 1.07%-2.44%). During the placebo sojourn, total sleep time (TST) with nPB was 54.3% (37.4%-80.8%) and 45.0% (24.5%-56.5%) during the first and the third night, respectively (P = 0.042). Increased inspiratory CO2 reduced TST with nPB by an absolute 38.1% (28.1%-48.1%), the apnoea-hypopnoea index by 58.1/h (40.1-76.1/h), and oxygen desaturation index ≥3% by 56.0/h (38.9.1-73.2/h) (all P < 0.001), whereas it increased the mean arterial oxygen saturation in TST by 2.0% (0.4%-3.5%, P = 0.035). Increased inspiratory CO2 slightly increased the percentage of N3 sleep during the third night (P = 0.045), without other effects on sleep architecture. Increasing inspiratory CO2 effectively prevented hypoxia-induced nPB without affecting sleep macro-architecture, indicating that nPB does not explain the sleep deterioration commonly observed at high altitudes. KEY POINTS: Periodic breathing is common during sleep at high altitude, and it is unclear how this affects sleep architecture. We developed a placebo-controlled approach to prevent nocturnal periodic breathing (nPB) with inspiratory CO2 administration and used it to assess the effects of nPB on sleep in hypobaric hypoxia. Nocturnal periodic breathing was effectively mitigated by an increased inspiratory CO2 fraction in a blinded manner. Prevention of nPB did not lead to relevant changes in sleep architecture in hypobaric hypoxia. We conclude that nPB does not explain the deterioration in sleep architecture commonly observed at high altitude.

3.
J Neurophysiol ; 131(4): 738-749, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38383290

RESUMO

Polysomnography (PSG) is the gold standard for clinical sleep monitoring, but its cost, discomfort, and limited suitability for continuous use present challenges. The flexible electrode sleep patch (FESP) emerges as an economically viable and patient-friendly solution, offering lightweight, simple operation, and self-applicable. Nevertheless, its utilization in young individuals remains uncertain. The objective of this study was to compare sleep data obtained by FESP and PSG in healthy young individuals and analyze agreement for sleep parameters and structure classification. Overnight monitoring with FESP and PSG recordings in 48 participants (mean age: 23 yr) was done. Correlation analysis, Bland-Altman plots, and Cohen's kappa coefficient assessed consistency. Sensitivity, specificity, and predictive values compared classification against PSG. FESP showed strong correlation and consistency with PSG for sleep monitoring. Bland-Altman plots indicated small errors and high consistency. Kappa values (0.70-0.84) suggested substantial agreement for sleep stage classification. Pearson correlation coefficient values for sleep stages (0.75-0.88) and sleep parameters (0.80-0.96) confirm that FESP has a strong application. Intraclass correlation coefficient yielded values between 0.65 and 0.97. In addition, FESP demonstrated an impressive accuracy range of 84.12-93.47% for sleep stage classification. The FESP also features a wearable self-test program with an error rate of no more than 8% for both deep sleep and wake. In young adults, FESP demonstrated reliable monitoring capabilities comparable to PSG. With its low cost and user-friendly design, FESP is a potential alternative for portable sleep assessment in clinical and research applications. Further studies involving larger populations are needed to validate its diagnostic potential.NEW & NOTEWORTHY By comparison with PSG, this study confirmed the reliability of an efficient, objective, low-cost, and noninvasive portable automatic sleep-monitoring device FESP, which provides effective information for long-term family sleep disorder diagnosis and sleep quality monitoring.


Assuntos
Actigrafia , Espiperona/análogos & derivados , Dispositivos Eletrônicos Vestíveis , Humanos , Adulto Jovem , Adulto , Polissonografia , Reprodutibilidade dos Testes , Sono , Eletrodos
4.
Thorax ; 79(10): 970-978, 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-38830667

RESUMO

BACKGROUND: Passengers on long-haul flights frequently consume alcohol. Inflight sleep exacerbates the fall in blood oxygen saturation (SpO2) caused by the decreased oxygen partial pressure in the cabin. We investigated the combined influence of alcohol and hypobaric hypoxia on sleep, SpO2 and heart rate. METHODS: Two groups of healthy individuals spent either two nights with a 4-hour sleep opportunity (00:00-04:00 hours) in the sleep laboratory (n=23; 53 m above sea level) or in the altitude chamber (n=17; 753 hPa corresponding to 2438 m above sea level, hypobaric condition). Participants consumed alcohol before one of the nights (mean±SE blood alcohol concentration 0.043±0.003%). The order of the nights was counterbalanced. Two 8-hour recovery nights (23:00-07:00 hours) were scheduled between conditions. Polysomnography, SpO2 and heart rate were recorded. RESULTS: The combined exposure to alcohol and hypobaric condition decreased SpO2 to a median (25th/75th percentile) of 85.32% (82.86/85.93) and increased heart rate to a median (25th/75th percentile) of 87.73 bpm (85.89/93.86) during sleep compared with 88.07% (86.50/88.49) and 72.90 bpm (70.90/78.17), respectively, in the non-alcohol hypobaric condition, 94.97% (94.59/95.33) and 76.97 bpm (65.17/79.52), respectively, in the alcohol condition and 95.88% (95.72/96.36) and 63.74 bpm (55.55/70.98), respectively, in the non-alcohol condition of the sleep laboratory group (all p<0.0001). Under the combined exposure SpO2 was 201.18 min (188.08/214.42) below the clinical hypoxia threshold of 90% SpO2 compared with 173.28 min (133.25/199.03) in the hypobaric condition and 0 min (0/0) in both sleep laboratory conditions. Deep sleep (N3) was reduced to 46.50 min (39.00/57.00) under the combined exposure compared with both sleep laboratory conditions (alcohol: 84.00 min (62.25/92.75); non-alcohol: 67.50 min (58.50/87.75); both p<0.003). CONCLUSIONS: The combination of alcohol and inflight hypobaric hypoxia reduced sleep quality, challenged the cardiovascular system and led to extended duration of hypoxaemia (SpO2 <90%).


Assuntos
Consumo de Bebidas Alcoólicas , Altitude , Frequência Cardíaca , Hipóxia , Saturação de Oxigênio , Polissonografia , Sono , Humanos , Frequência Cardíaca/fisiologia , Masculino , Consumo de Bebidas Alcoólicas/efeitos adversos , Adulto , Hipóxia/fisiopatologia , Feminino , Saturação de Oxigênio/fisiologia , Sono/fisiologia , Adulto Jovem , Medicina Aeroespacial , Oxigênio/sangue
5.
BMC Med ; 22(1): 134, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38519958

RESUMO

BACKGROUND: Alterations in sleep have been described in multiple health conditions and as a function of several medication effects. However, evidence generally stems from small univariate studies. Here, we apply a large-sample, data-driven approach to investigate patterns between in sleep macrostructure, quantitative sleep EEG, and health. METHODS: We use data from the MrOS Sleep Study, containing polysomnography and health data from a large sample (N = 3086) of elderly American men to establish associations between sleep macrostructure, the spectral composition of the electroencephalogram, 38 medical disorders, 2 health behaviors, and the use of 48 medications. RESULTS: Of sleep macrostructure variables, increased REM latency and reduced REM duration were the most common findings across health indicators, along with increased sleep latency and reduced sleep efficiency. We found that the majority of health indicators were not associated with objective EEG power spectral density (PSD) alterations. Associations with the rest were highly stereotypical, with two principal components accounting for 85-95% of the PSD-health association. PC1 consists of a decrease of slow and an increase of fast PSD components, mainly in NREM. This pattern was most strongly associated with depression/SSRI medication use and age-related disorders. PC2 consists of changes in mid-frequency activity. Increased mid-frequency activity was associated with benzodiazepine use, while decreases were associated with cardiovascular problems and associated medications, in line with a recently proposed hypothesis of immune-mediated circadian demodulation in these disorders. Specific increases in sleep spindle frequency activity were associated with taking benzodiazepines and zolpidem. Sensitivity analyses supported the presence of both disorder and medication effects. CONCLUSIONS: Sleep alterations are present in various health conditions.


Assuntos
Multimorbidade , Sono , Masculino , Humanos , Idoso , Estudos Transversais , Polissonografia , Eletroencefalografia , Benzodiazepinas
6.
Clin Endocrinol (Oxf) ; 100(3): 251-259, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38127470

RESUMO

CONTEXT: Although sleep disordered breathing (SDB) is well-recognised in acromegaly, most studies have reported heterogeneous, often heavily treated, groups and few have performed detailed sleep phenotyping at presentation. OBJECTIVE: To study SDB using the gold standard of polysomnography, in the largest group of newly-diagnosed, treatment-naïve patients with acromegaly. SETTING AND PATIENTS: 40 patients [22 males, 18 females; mean age 54 years (range 23-78)], were studied to: (i) establish the prevalence and severity of SDB (ii) assess the reliability of commonly employed screening tools [Epworth Sleepiness Scale (ESS) and overnight oxygen desaturation index (DI)] to detect SDB (iii) determine the extent to which sleep architecture is disrupted. RESULTS: Obstructive sleep apnoea (OSA), defined by the apnoea-hypopnoea index (AHI), was present in 79% of subjects (mild, n = 12; moderate, n = 5; severe, n = 14). However, in these individuals with OSA by AHI criteria, ESS (positive in 35% [n = 11]) and DI (positive in 71%: mild, n = 11; moderate, n = 6; severe, n = 5) markedly underestimated its prevalence/extent. Seventy-eight percent of patients exhibited increased arousal, with marked disruption of the sleep cycle, despite most (82%) having normal total time asleep. Fourteen patients spent longer in stage 1 sleep. Deeper sleep stages were severely attenuated in many subjects (reduced stage 2, n = 18; reduced slow wave sleep, n = 24; reduced rapid eye movement sleep, n = 32). CONCLUSION: Our study provides strong support for clinical guidelines that recommend screening for sleep apnoea syndrome in patients with newly-diagnosed acromegaly. Importantly, however, it highlights shortcomings in commonly recommended screening tools (questionnaires, desaturation index) and demonstrates the added value of polysomnography to allow timely detection of obstructive sleep apnoea and associated sleep cycle disruption.


Assuntos
Acromegalia , Apneia Obstrutiva do Sono , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Transversais , Prevalência , Estudos Prospectivos , Acromegalia/diagnóstico , Acromegalia/epidemiologia , Reprodutibilidade dos Testes , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/epidemiologia , Sono
7.
Mult Scler ; 30(6): 726-737, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38519434

RESUMO

BACKGROUND: Respiratory disorders remain incompletely described in multiple sclerosis (MS), even though they are a frequent cause of death. METHODS: The objective was to describe respiratory disorders in MS patients with Expanded Disability Status Score (EDSS) ⩾ 6.5. Diaphragm dysfunction was defined by at least two of the seven criteria: clinical signs, inspiratory recruitment of neck muscles during wakefulness, reduced upright vital capacity (VC) < 80%, upright-to-supine VC ⩾ 15% of upright VC, decrease in Maximal Inspiratory Pressure < 60%, phasic activation of inspiratory neck muscles during sleep, and opposition of thoracic and abdominal movements during sleep. Cough weakness was defined by a peak cough flow < 270 L/min and/or need for cough assist. Sleep apnea syndrome was defined by an apnea-hypopnea index ⩾ 15. RESULTS: Notably, 71 MS patients were included: median age 54 [48, 61] years; median disease duration 21.4 [16.0, 31.4] years. Of these, 52 patients had one or more respiratory disorders; diaphragm dysfunction was the most frequent (n = 34). Patients with diaphragm dysfunction and cough weakness were more disabled. The fatigue score and the cognitive evaluations did not differ between the groups. Five patients required non-invasive ventilation. CONCLUSION: Respiratory disorders are frequent in severe MS, mostly diaphragm dysfunction. Of interest, instrumental interventions are available to address these disorders.


Assuntos
Esclerose Múltipla , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Transversais , Esclerose Múltipla/complicações , Esclerose Múltipla/fisiopatologia , Transtornos Respiratórios/etiologia , Transtornos Respiratórios/fisiopatologia , Diafragma/fisiopatologia , Tosse/fisiopatologia , Tosse/etiologia , Índice de Gravidade de Doença , Síndromes da Apneia do Sono/fisiopatologia , Adulto
8.
J Sleep Res ; 33(2): e13946, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37226964

RESUMO

Obstructive sleep apnea (OSA) is commonly observed in children with Down syndrome (DS) and may affect their physical and psychological development. Currently, adenotonsillectomy is the first line treatment option for paediatric patients with OSA. However, surgical outcomes for such patients are not satisfactory. In this study, we analysed the efficacy and safety of adenotonsillectomy in the treatment of children with obstructive sleep apnea and Down syndrome. We systematically searched the PubMed, Web of Science, EMBASE, and the Cochrane databases and pooled data from nine relevant studies involving 384 participants. Subsequently, we analysed four outcomes in polysomnography, namely: net postoperative changes in the apnea-hypopnea index (AHI), the minimum oxygen saturation, sleep efficiency, and arousal index. Meta-analysis of the AHI showed a decrease of 7.18 events/h [95% CI (-9.69, -4.67) events/h; p < 0.00001] and an increase in the minimum oxygen saturation of 3.14% [95% CI (1.44, 4.84) %; p = 0.0003]. There was no significant increase in sleep efficiency [MD 1.69%, 95% CI (-0.59, 3.98) %; p = 0.15], but the arousal index significantly decreased by -3.21 events/hour [95% CI (-6.04, -0.38) events/h; p < 0.03]. In addition, the overall success rate was 16% (95% CI, 12%-21%) for postoperative AHI < 1 and 57% (95% CI, 51%-63%) for postoperative AHI <5. The postoperative complications recorded included airway obstruction and bleeding. This study demonstrated the efficacy of adenotonsillectomy as a treatment option for OSA. However, it is important to note that residual OSA and potential postoperative complications require further attention in future studies.


Assuntos
Síndrome de Down , Apneia Obstrutiva do Sono , Tonsilectomia , Criança , Humanos , Síndrome de Down/complicações , Síndrome de Down/cirurgia , Resultado do Tratamento , Tonsilectomia/efeitos adversos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/cirurgia , Complicações Pós-Operatórias/cirurgia
9.
J Sleep Res ; 33(1): e13985, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37414586

RESUMO

Sleep-related rhythmic movement disorder is characterised by stereotyped and repetitive rhythmic movements involving large muscle groups during sleep with frequencies between 0.5 and 2 Hz. Most of the published studies on sleep-related rhythmic movement disorder have focussed on children. Therefore, we performed a systematic review on this topic focussing on the adult population. The review is followed by a case report. The review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 guidelines. A total of seven manuscripts (n = 32 individuals) were included in the review. The clinical manifestation of body or head rolling predominated in the majority of included cases (53.13% and 43.75%, respectively). In n = 11 (34.37%) cases, a combination of rhythmic movements was observed. The literature review also revealed a wide spectrum of co-morbidities: insomnia, restless leg syndrome, obstructive sleep apnea, ischaemic stroke, epilepsy, hypertension, alcohol and drug dependency, mild depression, and diabetes mellitus. The case report presented a 33-year-old female who was referred to the sleep laboratory due to a suspicion of sleep bruxism and obstructive sleep apnea. Although the patient was initially suspected of having obstructive sleep apnea and sleep bruxism, after conducting video-polysomnography she met the criteria for sleep-related rhythmic movement disorder as she presented body rolling, which were surprisingly most evident during the rapid eye movement sleep stage. In summary, the prevalence of sleep-related rhythmic movement disorder among adults has not been determined yet. The present review and case report is a good starting point for discussion regarding rhythmic movement disorder in adults and further research on this topic.


Assuntos
Isquemia Encefálica , Transtornos dos Movimentos , Parassonias , Apneia Obstrutiva do Sono , Bruxismo do Sono , Acidente Vascular Cerebral , Adulto , Criança , Feminino , Humanos , Sono/fisiologia , Parassonias/complicações , Movimento
10.
J Sleep Res ; 33(1): e13897, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37020309

RESUMO

The nature and degree of objective sleep impairments in insomnia disorder remain unclear. This issue is complicated further by potential changes in sleep architecture on the first compared with subsequent nights in the laboratory. Evidence regarding differential first-night effects in people with insomnia disorder and controls is mixed. Here, we aimed to further characterize insomnia- and night-related differences in sleep architecture. A comprehensive set of 26 sleep variables was derived from two consecutive nights of polysomnography in 61 age-matched patients with insomnia and 61 good sleeper controls. People with insomnia expressed consistently poorer sleep than controls on several variables during both nights. While poorer sleep during the first night was observed in both groups, there were qualitative differences regarding the specific sleep variables expressing a first-night effect. Short sleep (total sleep time < 6 hr) was more likely during the first night and in insomnia, although approximately 40% of patients with insomnia presenting with short sleep on night 1 no longer met this criterion on night 2, which is important given the notion of short-sleeping insomnia as a robust subtype.


Assuntos
Distúrbios do Início e da Manutenção do Sono , Transtornos do Sono-Vigília , Humanos , Distúrbios do Início e da Manutenção do Sono/complicações , Sono , Polissonografia , Laboratórios
11.
J Sleep Res ; 33(1): e13942, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37254247

RESUMO

Polysomnographic studies have been performed to investigate the first-night effect in insomnia disorder. However, these studies have revealed discrepant findings. This meta-analysis aimed to summarise and quantify the characteristics of the first-night effect in insomnia disorder. We performed a systematic search of the PubMed, Medline, EMBASE, Web of Science and PsycINFO databases to identify studies published through October 2019. A total of 11,862 articles were identified, and seven studies with eight independent populations were included in the meta-analysis. A total of 639 patients with insomnia disorder and 171 healthy controls underwent more than 2 consecutive nights of in-laboratory polysomnography. Pooled results demonstrated that both variables of sleep continuity and sleep architecture, other than slow-wave sleep were significantly altered in the first-night effect in insomnia disorder. Furthermore, the results indicated that patients with insomnia disorder had a disruption of sleep continuity in the first-night effect, including increased sleep onset latency and reduced total sleep time, compared to healthy controls. Overall, the findings show that patients with insomnia disorder experience the first-night effect, rather than reverse first-night effect, and the profiles of the first-night effect in patients with insomnia are different from healthy controls. These indicate that an adaptation night is necessary when sleep continuity and sleep architecture is to be studied in patients with insomnia disorder. More well-designed studies with large samples are needed to confirm the results.


Assuntos
Distúrbios do Início e da Manutenção do Sono , Sono de Ondas Lentas , Humanos , Sono , Polissonografia/métodos , Latência do Sono
12.
J Sleep Res ; : e14235, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38873908

RESUMO

Sleep trackers are used widely by patients with sleep complaints, however their metrological validation is often poor and relies on healthy subjects. We assessed the metrological validity of two commercially available sleep trackers (Withings Activité/Fitbit Alta HR) through a prospective observational monocentric study, in adult patients referred for polysomnography (PSG). We compared the total sleep time (TST), REM time, REM latency, nonREM1 + 2 time, nonREM3 time, and wake after sleep onset (WASO). We report absolute and relative errors, Bland-Altman representations, and a contingency table of times spent in sleep stages with respect to PSG. Sixty-five patients were included (final sample size 58 for Withings and 52 for Fitbit). Both devices gave a relatively accurate sleep start time with a median absolute error of 5 (IQR -43; 27) min for Withings and -2.0 (-12.5; 4.2) min for Fitbit but both overestimated TST. Withings tended to underestimate WASO with a median absolute error of -25.0 (-61.5; -8.5) min, while Fitbit tended to overestimate it (median absolute error 10 (-18; 43) min. Withings underestimated light sleep and overestimated deep sleep, while Fitbit overestimated light and REM sleep and underestimated deep sleep. The overall kappas for concordance of each epoch between PSG and devices were low: 0.12 (95%CI 0.117-0.121) for Withings and VPSG indications 0.07 (95%CI 0.067-0.071) for Fitbit, as well as kappas for each VPSG indication 0.07 (95%CI 0.067-0.071). Thus, commercially available sleep trackers are not reliable for sleep architecture in patients with sleep complaints/pathologies and should not replace actigraphy and/or PSG.

13.
J Sleep Res ; 33(4): e14132, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38148606

RESUMO

The present study aimed to: (1) investigate sleep architecture in response to an overload training and taper periods among endurance runners; and (2) assess the sleep benefits of a high-heat-capacity mattress topper. Twenty-one trained male endurance runners performed a 2-week usual training regimen (baseline) followed by 2-week overload and taper periods. From overload to the end of the taper period, they were assigned into two groups based on the mattress topper used: high-heat-capacity mattress topper (n = 11) or low-heat-capacity mattress topper (n = 10). Training load was assessed daily using the session rating of perceived exertion. Following each period, sleep was monitored by polysomnography, and nocturnal core body temperature was recorded throughout the night. Irrespective of the group, awakening episodes > 5 min decreased following overload compared with baseline (-0.48, p = 0.05). Independently of mattress topper, each 100 A.U. increase in 7-day training load prior to polysomnographic recording was associated with higher slow-wave sleep proportion (ß = +0.13%; p = 0.05), lower sleep-onset latency (ß = -0.49 min; p = 0.05), and a reduction in the probability of transition from N1 sleep stage to wakefulness (ß = -0.12%; p = 0.05). Sleeping on a high-heat-capacity mattress topper did not affect any sleep variable compared with a low-heat-capacity mattress topper. Increased training loads promote slow-wave sleep and sleep propensity, highlighting the adaptative nature of sleep to diurnal activity and the role of sleep in physiological recovery. Further studies are required on the potential benefits of high-heat-capacity mattress toppers on sleep architecture among athletes.


Assuntos
Resistência Física , Polissonografia , Corrida , Sono , Humanos , Masculino , Corrida/fisiologia , Adulto , Sono/fisiologia , Resistência Física/fisiologia , Sono de Ondas Lentas/fisiologia , Temperatura Corporal/fisiologia , Temperatura Alta , Adulto Jovem , Leitos
14.
J Sleep Res ; : e14330, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39238202

RESUMO

People who use substances commonly experience sleep disruptions, affecting the regulation of physical and mental health, and presenting a significant barrier to treatment success. Sleep impairments are noted in all phases of substance use; however, differences between subjective versus objective methods used to measure sleep quality have been reported. While polysomnography is the gold-standard for sleep measurement, recent advances in actigraphy may help address the discordance between subjective and objective sleep reports. This systematic review examined emerging evidence (2016-present) for sleep impairment in people who use substances, with the twofold goal of: (1) identifying whether sleep outcomes vary across substance type (alcohol, nicotine, cannabis, cocaine, methamphetamine and opioids); and (2) contrasting results from subjective and objective measures. While some differences between subjective and objective sleep were noted, there was overwhelming evidence of clinically relevant sleep impairment in people who use alcohol, nicotine, cocaine, methamphetamine and opioids, with less consistent results for cannabis. Gaps in the literature are identified and future recommendations are presented, including utilization of common methodological frameworks, identification of mechanisms, and closer examination of sleep across stages of substance use and the interconnection between sleep and return to use.

15.
J Sleep Res ; : e14143, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38384163

RESUMO

The accuracy of actigraphy for sleep staging is assumed to be poor, but examination is limited. This systematic review aimed to assess the performance of actigraphy in sleep stage classification of adults. A systematic search was performed using MEDLINE, Web of Science, Google Scholar, and Embase databases. We identified eight studies that compared sleep architecture estimates between wrist-worn actigraphy and polysomnography. Large heterogeneity was found with respect to how sleep stages were grouped, and the choice of metrics used to evaluate performance. Quantitative synthesis was not possible, so we performed a narrative synthesis of the literature. From the limited number of studies, we found that actigraphy-based sleep staging had some ability to classify different sleep stages compared with polysomnography.

16.
J Sleep Res ; 33(2): e14015, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37572052

RESUMO

Automatic estimation of sleep structure is an important aspect in moving sleep monitoring from clinical laboratories to people's homes. However, the transition to more portable systems should not happen at the expense of important physiological signals, such as respiration. Here, we propose the use of cardiorespiratory signals obtained by a suprasternal pressure (SSP) sensor to estimate sleep stages. The sensor is already used for diagnosis of sleep-disordered breathing (SDB) conditions, but besides respiratory effort it can detect cardiac vibrations transmitted through the trachea. We collected the SSP sensor signal in 100 adults (57 male) undergoing clinical polysomnography for suspected sleep disorders, including sleep apnea syndrome, insomnia, and movement disorders. Here, we separate respiratory effort and cardiac activity related signals, then input these into a neural network trained to estimate sleep stages. Using the original mixed signal the results show a moderate agreement with manual scoring, with a Cohen's kappa of 0.53 in Wake/N1-N2/N3/rapid eye movement sleep discrimination and 0.62 in Wake/Sleep. We demonstrate that decoupling the two signals and using the cardiac signal to estimate the instantaneous heart rate improves the process considerably, reaching an agreement of 0.63 and 0.71. Our proposed method achieves high accuracy, specificity, and sensitivity across different sleep staging tasks. We also compare the total sleep time calculated with our method against manual scoring, with an average error of -1.83 min but a relatively large confidence interval of ±55 min. Compact systems that employ the SSP sensor information-rich signal may enable new ways of clinical assessments, such as night-to-night variability in obstructive sleep apnea and other sleep disorders.


Assuntos
Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Adulto , Humanos , Masculino , Síndromes da Apneia do Sono/diagnóstico , Sono/fisiologia , Algoritmos , Fases do Sono/fisiologia
17.
J Sleep Res ; 33(2): e13957, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37246335

RESUMO

Sleep bruxism (SB) has been associated with biological and psychosocial factors. The assessment of SB includes self-report, clinical evaluation, and polysomnography. This study aimed to investigate the associations of self-reported SB with other sleep disorders and demographic, psychological, and lifestyle factors in the adult general population, and to investigate whether self-reported SB and polysomnographically (PSG) confirmed SB provide similar outcomes in terms of their associated factors. We recruited 915 adults from the general population in Sao Paulo, Brazil. All participants underwent a one-night PSG recording and answered questions about sex, age, BMI, insomnia, OSA risk, anxiety, depression, average caffeine consumption, smoking frequency, and alcohol consumption frequency. We investigated the link between SB and the other variables in univariate, multivariate, and network models, and we repeated each model once with self-reported SB and once with PSG-confirmed SB. Self-reported SB was only significantly associated with sex (p = 0.042), anxiety (p = 0.002), and depression (p = 0.03) in the univariate analysis, and was associated with insomnia in the univariate (p < 0.001) and multivariate (ß = 1.054, 95%CI 1.018-1.092, p = 0.003) analyses. Network analysis showed that self-reported SB had a direct positive edge to insomnia, while PSG-confirmed SB was not significantly associated with any of the other variables. Thus, sleep bruxism was positively associated with insomnia only when self-reported, while PSG-confirmed SB was not associated with any of the included factors.


Assuntos
Bruxismo do Sono , Distúrbios do Início e da Manutenção do Sono , Adulto , Humanos , Distúrbios do Início e da Manutenção do Sono/epidemiologia , Distúrbios do Início e da Manutenção do Sono/complicações , Bruxismo do Sono/epidemiologia , Brasil/epidemiologia , Polissonografia , Autorrelato , Sono
18.
J Sleep Res ; 33(4): e14126, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38112275

RESUMO

Acute exercise has been shown to affect long-term memory and sleep. However, it is unclear whether exercise-induced changes in sleep architecture are associated with enhanced memory. Recently, it has been shown that exercise followed by a nap improved declarative memory. Whether these effects transfer to night sleep and other memory domains has not yet been studied. Here, we investigate the influence of exercise on nocturnal sleep architecture and associations with sleep-dependent procedural and declarative memory consolidation. Nineteen subjects (23.68 ± 3.97 years) were tested in a balanced cross-over design. In two evening sessions, participants either exercised (high-intensity interval training) or rested immediately after encoding two memory tasks: (1) a finger tapping task and (2) a paired-associate learning task. Subsequent nocturnal sleep was recorded by polysomnography. Retrieval was conducted the following morning. High-intensity interval training lead to an increased declarative memory retention (p = 0.047, d = 0.40) along with a decrease in REM sleep (p = 0.012, d = 0.75). Neither procedural memory nor NREM sleep were significantly affected. Exercise-induced changes in N2 showed a positive correlation with procedural memory retention which did not withstand multiple comparison correction. Exploratory analyses on sleep spindles and slow wave activity did not reveal significant effects. The present findings suggest an exercise-induced enhancement of declarative memory which aligns with changes in nocturnal sleep architecture. This gives additional support for the idea of a potential link between exercise-induced sleep modifications and memory formation which requires further investigation in larger scaled studies.


Assuntos
Estudos Cross-Over , Exercício Físico , Consolidação da Memória , Polissonografia , Sono , Humanos , Consolidação da Memória/fisiologia , Masculino , Feminino , Adulto , Adulto Jovem , Exercício Físico/fisiologia , Sono/fisiologia , Treinamento Intervalado de Alta Intensidade/métodos , Fases do Sono/fisiologia , Eletroencefalografia , Sono REM/fisiologia
19.
J Sleep Res ; : e14187, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38410055

RESUMO

Electroencephalograms can capture brain oscillatory activities during sleep as a form of electrophysiological signals. We analysed electroencephalogram recordings from full-night in-laboratory polysomnography from 100 patients with Down syndrome, and 100 age- and sex-matched controls. The ages of patients with Down syndrome spanned 1 month to 31 years (median 4.4 years); 84 were younger than 12 years, and 54 were male. From each electroencephalogram, we extracted relative power in six frequency bands or rhythms (delta, theta, alpha, slow sigma, fast sigma, and beta) from six channels (frontal F3 and F4, central C3 and C4, and occipital O1 and O2) during five sleep stages (N3, N2, N1, R and W)-180 features in all. We examined differences in relative power between Down syndrome and control electroencephalograms for each feature separately. During wake and N1 sleep stages, alpha rhythms (8.0-10.5 Hz) had significantly lower power in patients with Down syndrome than controls. Moreover, the rate of increase in alpha power with age during rapid eye movement sleep was significantly slower in Down syndrome than control subjects. During wake and N1 sleep, delta rhythms (0.25-4.5 Hz) had higher power in patients with Down syndrome than controls. During N2 sleep, slow sigma rhythms (10.5-12.5 Hz) had lower power in patients with DS than controls. These findings extend previous research from routine electroencephalogram studies demonstrating that patients with Down syndrome had reduced circadian amplitude-the difference between wake alpha power and deep sleep delta power was smaller in Down syndrome than control subjects. We envision that these brain oscillatory activities may be used as surrogate markers for clinical trials for patients with Down syndrome.

20.
J Sleep Res ; : e14286, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39049464

RESUMO

In-laboratory polysomnography, the gold-standard for diagnosing sleep disorders, is resource-demanding and not conducive to multiple night evaluations. Ambulatory polysomnography, especially when self-applied, could be a viable alternative. This study aimed to assess the feasibility and reliability of self-applied polysomnography over three consecutive nights in untrained participants, assessing: technical success rate; comparing sleep diagnostic variables from single and multiple nights; and evaluating participants' subjective experience. Data were collected from 78 participants (55.1% females) invited to test a self-applicable polysomnography device for three consecutive nights at home. The technical success rate for valid sleep recordings was 82.5% out of 234 planned study nights, with 87.2% of participants obtaining at least two valid nights. Misclassification of obstructive sleep apnea severity was higher in participants with mild OSA (21.4%) compared with those with moderate-to-severe obstructive sleep apnea or no obstructive sleep apnea. Sleep efficiency and wake after sleep onset showed improvement from Night 1 to Night 3 (p < 0.001), and the mean polysomnography set-up time decreased significantly over this period. Participants reported moderate-to-high satisfaction with the device (System Usability Scale score 71.2 ± 12.4). The findings suggest that self-applied polysomnography is a feasible diagnostic method for untrained individuals at risk for sleep disorders, and that multiple night assessments can improve diagnostic precision for mild obstructive sleep apnea cases.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa