Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
Proc Natl Acad Sci U S A ; 121(11): e2304009121, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38442161

RESUMO

Elastin is an extracellular matrix material found in all vertebrates. Its reversible elasticity, robustness, and low stiffness are essential for the function of arteries, lungs, and skin. It is among the most resilient elastic materials known: During a human lifetime, arterial elastin undergoes in excess of 2 × 109 stretching/contracting cycles without replacement, and slow oxidative hardening has been identified as a limiting factor on human lifespan. For over 50 y, the mechanism of entropic recoil has been controversial. Herein, we report a combined NMR and thermomechanical study that establishes the hydrophobic effect as the primary driver of elastin function. Water ordering at the solvent:protein interface was observed as a function of stretch using double quantum 2H NMR, and the most extensive thermodynamic analysis performed to date was obtained by measuring elastin length and volume as a function of force and temperature in normal water, heavy water and with cosolvents. When stretched, elastin's heat capacity increases, water is ordered proportional to the degree of stretching, the internal energy decreases, and heat is released in excess of the work performed. These properties show that recoil in elastin under physiological conditions is primarily driven by the hydrophobic effect rather than by configurational entropy as is the case for rubber. Consistent with this conclusion are decreases in the thermodynamic signatures when cosolvents that alter the hydrophobic effect are introduced. We propose that hydrophobic effect-driven recoil, as opposed to a configurational entropy mechanism where hardening from crystallization can occur, is the origin of elastin's unusual resilience.


Assuntos
Elastina , Animais , Humanos , Artérias/química , Cristalização , Elastina/química , Termodinâmica , Água
2.
Am J Physiol Heart Circ Physiol ; 327(4): H1098-H1111, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39178029

RESUMO

Septic cardiomyopathy (SCM) with diastolic dysfunction carries a poor prognosis, and the mechanisms underlying the development of diastolic dysfunction remain unclear. Matrix metalloproteinase-8 (MMP-8) is released from neutrophils and degrades collagen I. MMP-8 levels correlate with SCM severity. We scrutinized, for the first time, the direct impact of MMP-8 on cardiac systolic and diastolic functions. Isolated rat hearts were perfused with Krebs-Henseleit solution in a Langendorff setup with computer-controlled filling pressures of both ventricles in an isovolumetric regime. The end-diastolic pressure (EDP) varied periodically between 3 and 20 mmHg. After baseline recordings, MMP-8 (100 µg/mL) was added to the perfusion. Short-axis views of both ventricles were continuously acquired by echocardiography. MMP-8 perfusion resulted in a progressive decline in peak systolic pressures (Psys) in both ventricles, but without significant changes in their end-systolic pressure-area relationships (ESPARs). Counterintuitively, conspicuous leftward shifts of the end-diastolic pressure-area relationships (EDPARs) were observed in both ventricles. The left ventricle (LV) end-diastolic area (EDA) decreased by 32.8 ± 5.7% (P = 0.008) at an EDP of 10.5 ± 0.4 mmHg, when LV Psys dropped by 20%. The decline of Psys was primarily due to the decrease in EDA, and restoring the baseline EDA by increasing EDP recovered 81.33 ± 5.87% of the pressure drop. Collagen I generates tensile (eccentric) stress, and its degradation by MMP-8 causes end-diastolic pressure-volume relationship (EDPVR) leftward shift, resulting in diastolic and systolic dysfunctions. The diastolic dysfunction explains the clinically observed fluid unresponsiveness, whereas the decrease in end-diastolic volume (EDV) diminishes the systolic functions. MMP-8 can explain the development of SCM with diastolic dysfunction.NEW & NOTEWORTHY MMP-8, released from activated neutrophils and macrophages, is markedly elevated in sepsis, correlating with sepsis severity and mortality. MMP-8 targets collagen I of the cardiac ECM and induces diastolic dysfunction with fluid unresponsiveness, associated with decreased EDV, reduced sarcomere length, and diminished systolic function. Unlike other MMPs that predominantly cleave collagen-III and contribute to cardiac dilatation, thereby increasing sarcomere length, MMP-8 leads to a leftward shift in the EDPVR, resulting in diastolic and systolic dysfunctions.


Assuntos
Cardiomiopatias , Diástole , Metaloproteinase 8 da Matriz , Função Ventricular Esquerda , Pressão Ventricular , Animais , Metaloproteinase 8 da Matriz/metabolismo , Masculino , Cardiomiopatias/fisiopatologia , Cardiomiopatias/enzimologia , Cardiomiopatias/metabolismo , Cardiomiopatias/etiologia , Ratos , Sepse/fisiopatologia , Sepse/complicações , Ratos Wistar , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/metabolismo , Disfunção Ventricular Esquerda/enzimologia , Volume Sistólico , Preparação de Coração Isolado
3.
J Synchrotron Radiat ; 31(Pt 5): 1134-1145, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39120914

RESUMO

The ability to freely control the polarization of X-rays enables measurement techniques relying on circular or linear dichroism, which have become indispensable tools for characterizing the properties of chiral molecules or magnetic structures. Therefore, the demand for polarization control in X-ray free-electron lasers is increasing to enable polarization-sensitive dynamical studies on ultrafast time scales. The soft X-ray branch Athos of SwissFEL was designed with the aim of providing freely adjustable and arbitrary polarization by building its undulator solely from modules of the novel Apple X type. In this paper, the magnetic model of the linear inclined and circular Apple X polarization schemes are studied. The polarization is characterized by measuring the angular electron emission distributions of helium for various polarizations using cold target recoil ion momentum spectroscopy. The generation of fully linear polarized light of arbitrary angle, as well as elliptical polarizations of varying degree, are demonstrated.

4.
Artif Organs ; 2024 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-39445696

RESUMO

BACKGROUND: Poly-L-lactic acid (PLLA) is one of the representative polymeric materials serving as bioresorbable stents (BRS) for cardiovascular disease due to its proper biodegradation, high biocompatibility, and adequate mechanical properties among polymer candidates for BRS. However, PLLA BRS as cardiovascular stents also have limitations because their mechanical properties including low radial strength and high elastic recoil are inferior to those of metallic-based BRS stents. METHODS: In the study, we developed and manufactured distinct and novel types of stent geometries for investigating mechanical properties of thin-walled PLLA BRS (110 µm) for cardiovascular applications. Five key mechanical tests, including radial strength, crimping profile, flexibility, elastic recoil, and foreshortening were performed through a comprehensive analysis. In addition, we applied the finite element method for further validation and insight of mechanical behaviors of the PLLA BRS. RESULTS: Results revealed that Model 2 had advantages in high flexibility as well as radial strengths, which would be a proper option for complex and acutely curved lesions. Model 3 would be an optimum selection for stent placement in mild target site due to its strength in minimum elastic recoil. Even though Model 4 showed the highest radial strength, finite element simulation showed that the geometry caused higher maximum stress than that of Model 2 and Model 3 during the crimping process. Model 1 showed the most vulnerable geometry among the tested models in both in vitro and finite element analysis. CONCLUSION: Such data may suggest potential guidance in regard to understanding the mechanical behaviors of PLLA BRS as not only applicable cardiovascular but also peripheral and intracranial stents.

5.
Microsc Microanal ; 30(1): 49-58, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38232229

RESUMO

In this paper, the capability for quantifying the composition of Ba-doped SrTiO layers from an atom probe measurement was explored. Rutherford backscattering spectrometry and time-of-flight/energy elastic recoil detection were used to benchmark the composition where the amount of titanium was intentionally varied between samples. The atom probe results showed a significant divergence from the benchmarked composition. The cause was shown to be a significant oxygen underestimation (≳14 at%). The ratio between oxygen and titanium for the samples varied between 2.6 and 12.7, while those measured by atom probe tomography were lower and covered a narrower range between 1.4 and 1.7. This difference was found to be associated with the oxygen and titanium predominantly field evaporating together as a molecular ion. The evaporation fields and bonding chemistries determined showed inconsistencies for explaining the oxygen underestimation and ion species measured. The measured ion charge state was in excellent agreement with that predicted by the Kingham postionization theory. Only by considering the measured ion species, their evaporation fields, the coordination chemistry, the analysis conditions, and some recently reported density functional theory modeling for oxide field emission were we able to postulate a field emission and oxygen neutral desorption process that may explain our results.

6.
Sensors (Basel) ; 24(12)2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38931519

RESUMO

The domain of gamma-ray imaging necessitates technological advancements to surmount the challenge of energy-selective imaging. Conventional systems are constrained in their dynamic focus on specific energy ranges, a capability imperative for differentiating gamma-ray emissions from diverse sources. This investigation introduces an innovative imaging system predicated on the detection of recoil electrons, addressing the demand for adjustable energy selectivity. Our methodology encompasses the design of a gamma-ray imaging system that leverages recoil electron detection to execute energy-selective imaging. The system's efficacy was investigated experimentally, with emphasis on the adaptability of the energy selection window. The experimental outcomes underscore the system's adeptness at modulating the energy selection window, adeptly discriminating gamma rays across a stipulated energy spectrum. The results corroborate the system's adaptability, with an adjustable energy resolution that coincides with theoretical projections and satisfies the established criteria. This study affirms the viability and merits of utilizing recoil electrons for tunable energy-selective gamma-ray imaging. The system's conceptualization and empirical validation represent a notable progress in gamma-ray imaging technology, with prospective applications extending from medical imaging to astrophysics. This research sets a solid foundation for subsequent inquiries and advancements in this domain.

7.
J Exp Biol ; 226(19)2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37727106

RESUMO

Changes in temperature alter muscle kinetics and in turn affect whole-organism performance. Some organisms use the elastic recoil of biological springs, structures which are far less temperature sensitive, to power thermally robust movements. For jumping frogs, the use of elastic energy in tendons is facilitated through a geometric latching mechanism that operates through dynamic changes in the mechanical advantage (MA) of the hindlimb. Despite the well-documented use of elastic energy storage, frog jumping is a locomotor behavior that is significantly affected by changes in temperature. Here, we used an in vitro muscle preparation interacting in real time with an in silico model of a legged jumper to understand how changes in temperature affect the flow of energy in a system using a MA latch. We used the plantaris longus muscle-tendon unit (MTU) to power a virtual limb with changing MA and a mass being accelerated through a real-time feedback controller. We quantified the amount of energy stored in and recovered from elastic structures and the additional contribution of direct muscle work after unlatching. We found that temperature altered the duration of the energy loading and recovery phase of the in vitro/in silico experiments. We found that the early phase of loading was insensitive to changes in temperature. However, an increase in temperature did increase the rate of force development, which in turn allowed for increased energy storage in the second phase of loading. We also found that the contribution of direct muscle work after unlatching was substantial and increased significantly with temperature. Our results show that the thermal robustness achieved by an elastic mechanism depends strongly on the nature of the latch that mediates energy flow, and that the relative contribution of elastic and direct muscle energy likely shapes the thermal sensitivity of locomotor systems.


Assuntos
Contração Muscular , Músculo Esquelético , Animais , Temperatura , Contração Muscular/fisiologia , Fenômenos Biomecânicos , Músculo Esquelético/fisiologia , Extremidade Inferior , Anuros/fisiologia
8.
J Exp Biol ; 226(21)2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37767690

RESUMO

Many animals use a combination of skeletal muscle and elastic structures to amplify power output for fast motions. Among vertebrates, tendons in series with skeletal muscle are often implicated as the primary power-amplifying spring, but muscles contain elastic structures at all levels of organization, from the muscle tendon to the extracellular matrix to elastic proteins within sarcomeres. The present study used ex vivo muscle preparations in combination with high-speed video to quantify power output, as the product of force and velocity, at several levels of muscle organization to determine where power amplification occurs. Dynamic ramp-shortening contractions in isolated frog flexor digitorum superficialis brevis were compared with isotonic power output to identify power amplification within muscle fibers, the muscle belly, free tendon and elements external to the muscle tendon. Energy accounting revealed that artifacts from compliant structures outside of the muscle-tendon unit contributed significant peak instantaneous power. This compliance included deflection of clamped bone that stored and released energy contributing 195.22±33.19 W kg-1 (mean±s.e.m.) to the peak power output. In addition, we found that power detected from within the muscle fascicles for dynamic shortening ramps was 338.78±16.03 W kg-1, or approximately 1.75 times the maximum isotonic power output of 195.23±8.82 W kg-1. Measurements of muscle belly and muscle-tendon unit also demonstrated significant power amplification. These data suggest that intramuscular tissues, as well as bone, have the capacity to store and release energy to amplify whole-muscle power output.


Assuntos
Músculo Esquelético , Tendões , Animais , Fenômenos Biomecânicos , Músculo Esquelético/fisiologia , Tendões/fisiologia , Contração Muscular/fisiologia , Sarcômeros
9.
J Endovasc Ther ; : 15266028231215284, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38059463

RESUMO

PURPOSE: Recoil following balloon angioplasty of tibial arteries is a known mechanism of lumen loss and widely considered to be a contributing factor in early failure or later restenosis. The Serranator balloon has been designed to provide a controlled lumen gain while minimizing vessel injury. The objective of this study was to assess the ability to define and measure postangioplasty recoil in infrapopliteal arteries and to compare recoil after serration angioplasty and plain balloon angioplasty (POBA). METHODS: This multi-center, sequential comparative study included patients with de novo or restenotic lesions of infrapopliteal arteries up to 22 cm in length. Patients were enrolled sequentially and underwent alternating POBA or serration angioplasty with Serranator. The study captured angiographic imaging at pre, immediately post, and 15-minute after angioplasty. Vessel recoil, final diameter stenosis, and dissection were compared using core laboratory analysis. RESULTS: This study enrolled 36 patients who underwent treatment of 39 infrapopliteal lesions. There was no significant difference between Serranator (n=20) and POBA (n=19) with respect to baseline demographics and lesion characteristics. Arterial recoil (>10%) occurred in 25% of Serranator-treated lesions versus 64% in POBA-treated lesions (p=0.02. Clinically relevant recoil (>30%) was present after serration angioplasty in 10% of patients and after POBA in 53% (p=0.01). There was no significant difference in technical success (100% for both), dissection rate between Serranator (5%) and POBA (5.2%). CONCLUSIONS: Arterial recoil occurs after infrapopliteal angioplasty. Serration angioplasty produces substantially less arterial recoil compared with POBA. Additional studies are needed to assess whether reduced arterial recoil translates into superior long-term clinical outcomes. CLINICAL IMPACT: Prior studies have demonstrated over 90% recoil in patients after balloon angioplasty (POBA) of the infrapopliteal vessels, which significantly impacts the durability and impact of endovascular interventions in this clinical space. This study compared recoil after infrapopliteal angioplasty with serration angioplasty and POBA. Serration angioplasty produces substantially less arterial recoil compared with POBA. Additional studies are needed to assess whether reduced arterial recoil translates into superior long-term clinical outcomes.

10.
J Exp Biol ; 225(14)2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35863219

RESUMO

Small organisms use propulsive springs rather than muscles to repeatedly actuate high acceleration movements, even when constrained to tiny displacements and limited by inertial forces. Through integration of a large kinematic dataset, measurements of elastic recoil, energetic math modeling and dynamic math modeling, we tested how trap-jaw ants (Odontomachus brunneus) utilize multiple elastic structures to develop ultrafast and precise mandible rotations at small scales. We found that O. brunneus develops torque on each mandible using an intriguing configuration of two springs: their elastic head capsule recoils to push and the recoiling muscle-apodeme unit tugs on each mandible. Mandibles achieved precise, planar, circular trajectories up to 49,100 rad s-1 (470,000 rpm) when powered by spring propulsion. Once spring propulsion ended, the mandibles moved with unconstrained and oscillatory rotation. We term this mechanism a 'dual spring force couple', meaning that two springs deliver energy at two locations to develop torque. Dynamic modeling revealed that dual spring force couples reduce the need for joint constraints and thereby reduce dissipative joint losses, which is essential to the repeated use of ultrafast, small systems. Dual spring force couples enable multifunctionality: trap-jaw ants use the same mechanical system to produce ultrafast, planar strikes driven by propulsive springs and for generating slow, multi-degrees of freedom mandible manipulations using muscles, rather than springs, to directly actuate the movement. Dual spring force couples are found in other systems and are likely widespread in biology. These principles can be incorporated into microrobotics to improve multifunctionality, precision and longevity of ultrafast systems.


Assuntos
Formigas , Animais , Formigas/fisiologia , Fenômenos Biomecânicos , Mandíbula/fisiologia , Movimento/fisiologia
11.
J Exp Biol ; 225(16)2022 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-35875854

RESUMO

Evidence suggests that the giant muscle protein titin functions as a tunable spring in active muscle. However, the mechanisms for increasing titin stiffness with activation are not well understood. Previous studies have suggested that during muscle activation, titin binds to actin, which engages the PEVK region of titin, thereby increasing titin stiffness. In this study, we investigated the role of PEVK titin in active muscle stiffness during rapid unloading. We measured elastic recoil of active and passive soleus muscles from TtnΔ112-158 mice characterized by a 75% deletion of PEVK titin and increased passive stiffness. We hypothesized that activated TtnΔ112-158 muscles are stiffer than wild-type muscles as a result of the increased stiffness of PEVK titin. Using a servomotor force lever, we compared the stress-strain relationships of elastic elements in active and passive muscles during rapid unloading and quantified the change in stiffness upon activation. The results show that the elastic modulus of TtnΔ112-158 muscles increased with activation. However, elastic elements developed force at 7% longer lengths and exhibited 50% lower active stiffness in TtnΔ112-158 soleus muscles than in wild-type muscles. Thus, despite having a shorter, stiffer PEVK segment, during rapid unloading, TtnΔ112-158 soleus muscles exhibited reduced active stiffness compared with wild-type soleus muscles. These results are consistent with the idea that PEVK titin contributes to active muscle stiffness; however, the reduction in active stiffness of TtnΔ112-158 muscles suggests that other mechanisms compensate for the increased PEVK stiffness.


Assuntos
Proteínas Musculares , Músculo Esquelético , Proteínas Quinases/metabolismo , Animais , Conectina/genética , Módulo de Elasticidade , Camundongos , Proteínas Musculares/fisiologia , Músculo Esquelético/fisiologia , Proteínas Quinases/genética
12.
Proc Natl Acad Sci U S A ; 116(11): 4877-4882, 2019 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-30733297

RESUMO

Observing and controlling molecular motion and in particular rotation are fundamental topics in physics and chemistry. To initiate ultrafast rotation, one needs a way to transfer a large angular momentum to the molecule. As a showcase, this was performed by hard X-ray C1s ionization of carbon monoxide accompanied by spinning up the molecule via the recoil "kick" of the emitted fast photoelectron. To visualize this molecular motion, we use the dynamical rotational Doppler effect and an X-ray "pump-probe" device offered by nature itself: the recoil-induced ultrafast rotation is probed by subsequent Auger electron emission. The time information in our experiment originates from the natural delay between the C1s photoionization initiating the rotation and the ejection of the Auger electron. From a more general point of view, time-resolved measurements can be performed in two ways: either to vary the "delay" time as in conventional time-resolved pump-probe spectroscopy and use the dynamics given by the system, or to keep constant delay time and manipulate the dynamics. Since in our experiment we cannot change the delay time given by the core-hole lifetime τ, we use the second option and control the rotational speed by changing the kinetic energy of the photoelectron. The recoil-induced rotational dynamics controlled in such a way is observed as a photon energy-dependent asymmetry of the Auger line shape, in full agreement with theory. This asymmetry is explained by a significant change of the molecular orientation during the core-hole lifetime, which is comparable with the rotational period.

13.
Small ; 17(12): e2006449, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33615690

RESUMO

Different propulsion mechanisms have been suggested for describing the motion of a variety of chemical micromotors, which have attracted great attention in the last decades due to their high efficiency and thrust force, enabling several applications in the fields of environmental remediation and biomedicine. Bubble-recoil based motion, in particular, has been modeled by three different phenomena: capillary forces, bubble growth, and bubble expulsion. However, these models have been suggested independently based on a single influencing factor (i.e., viscosity), limiting the understanding of the overall micromotor performance. Therefore, the combined effect of medium viscosity, surface tension, and fuel concentration is analyzed on the micromotor swimming ability, and the dominant propulsion mechanisms that describe its motion more accurately are identified. Using statistically relevant experimental data, a holistic theoretical model is proposed for bubble-propelled tubular catalytic micromotors that includes all three above-mentioned phenomena and provides deeper insights into their propulsion physics toward optimized geometries and experimental conditions.


Assuntos
Recuperação e Remediação Ambiental , Catálise , Movimento (Física)
14.
Exp Physiol ; 106(2): 532-543, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33174314

RESUMO

NEW FINDINGS: What is the central question of this study? The study aimed to establish a novel model to study the chronic obstructive pulmonary disease (COPD)-related cardiopulmonary effects of dynamic hyperinflation in healthy subjects. What is the main finding and its importance? A model of expiratory resistance breathing (ERB) was established in which dynamic hyperinflation was induced in healthy subjects, expressed both by lung volumes and intrathoracic pressures. ERB outperformed existing methods and represents an efficacious model to study cardiopulmonary mechanics of dynamic hyperinflation without potentially confounding factors as present in COPD. ABSTRACT: Dynamic hyperinflation (DH) determines symptoms and prognosis of chronic obstructive pulmonary disease (COPD). The induction of DH is used to study cardiopulmonary mechanics in healthy subjects without COPD-related confounders like inflammation, hypoxic vasoconstriction and rarefication of pulmonary vasculature. Metronome-paced tachypnoea (MPT) has proven effective in inducing DH in healthy subjects, but does not account for airflow limitation. We aimed to establish a novel model incorporating airflow limitation by combining tachypnoea with an expiratory airway stenosis. We investigated this expiratory resistance breathing (ERB) model in 14 healthy subjects using different stenosis diameters to assess a dose-response relationship. Via cross-over design, we compared ERB to MPT in a random sequence. DH was quantified by inspiratory capacity (IC, litres) and intrinsic positive end-expiratory pressure (PEEPi, cmH2 O). ERB induced a stepwise decreasing IC (means (95% CI): tidal breathing: 3.66 (3.45-3.88), ERB 3 mm: 3.33 (1.75-4.91), 2 mm: 2.05 (0.76-3.34), 1.5 mm: 0.73 (0.12-1.58) litres) and increasing PEEPi (tidal breathing: 0.70 (0.50-0.80), ERB 3 mm: 11.1 (7.0-15.2), 2 mm: 22.3 (17.1-27.6), 1.5 mm: 33.4 (3.40-63) cmH2 O). All three MPT patterns increased PEEPi, but to a far lesser extent than ERB. No adverse events during ERB were noted. In conclusion, ERB was proven to be a safe and efficacious model for the induction of DH and might be used for the investigation of cardiopulmonary interaction in healthy subjects.


Assuntos
Pulmão/fisiologia , Respiração , Adulto , Estudos Cross-Over , Voluntários Saudáveis , Humanos , Capacidade Inspiratória , Masculino , Adulto Jovem
15.
J Exp Biol ; 224(24)2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34821932

RESUMO

Elastic recoil drives some of the fastest and most powerful biological movements. For effective use of elastic recoil, the tuning of muscle and spring force capacity is essential. Although studies of invertebrate organisms that use elastic recoil show evidence of increased force capacity in their energy loading muscle, changes in the fundamental properties of such muscles have yet to be documented in vertebrates. Here, we used three species of frogs (Cuban tree frogs, bullfrogs and cane toads) that differ in jumping power to investigate functional shifts in muscle-spring tuning in systems using latch-mediated spring actuation (LaMSA). We hypothesized that variation in jumping performance would result from increased force capacity in muscles and relatively stiffer elastic structures, resulting in greater energy storage. To test this, we characterized the force-length property of the plantaris longus muscle-tendon unit (MTU), and quantified the maximal amount of energy stored in elastic structures for each species. We found that the plantaris longus MTU of Cuban tree frogs produced higher mass-specific energy and mass-specific forces than the other two species. Moreover, we found that the plantaris longus MTU of Cuban tree frogs had higher pennation angles than the other species, suggesting that muscle architecture was modified to increase force capacity through packing of more muscle fibers. Finally, we found that the elastic structures were relatively stiffer in Cuban tree frogs. These results provide a mechanistic link between the tuned properties of LaMSA components, energy storage capacity and whole-system performance.


Assuntos
Contração Muscular , Músculo Esquelético , Animais , Anuros/fisiologia , Fenômenos Biomecânicos/fisiologia , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia , Tendões/fisiologia
16.
Circ J ; 85(9): 1575-1583, 2021 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-33840657

RESUMO

BACKGROUND: It is well acknowledged that left ventricular (LV) contractile performance affects LV relaxation via LV elastic recoil. Accordingly, we aimed to investigate whether global longitudinal strain (GLS), particularly longitudinal strain at LV apical segments at end-systole (ALS), obtained by 2-dimensional speckle-tracking echocardiography could be used to assess LV relaxation.Methods and Results:We enrolled 121 patients with suspected or definite coronary artery disease in whom echocardiography and diagnostic cardiac catheterization were performed on the same day. We obtained conventional echo-Doppler parameters and GLS, as well as ALS prior to catheterization. LV functional parameters were obtained from the LV pressure recorded using a catheter-tipped micromanometer. In all patients, GLS and ALS were significantly correlated with the time constant τ of LV pressure decay during isovolumetric relaxation (r=0.63 [P<0.001] and r=0.66 [P<0.001], respectively). Receiver operating characteristic curve analysis for identifying impaired LV relaxation (τ ≥48 ms) revealed that ALS greater than -22.3% was an optimal cut-off value, with 81.7% sensitivity and 82.4% specificity. Even in patients with preserved LV ejection fraction, the same ALS cut-off value enabled the identification of impaired LV relaxation with 70% sensitivity and 87.5% specificity. CONCLUSIONS: The findings indicate that contractile dysfunction at LV apical segments slows LV relaxation via loss of LV elastic recoil, even in patients with preserved LVEF.


Assuntos
Ecocardiografia , Ventrículos do Coração , Ventrículos do Coração/diagnóstico por imagem , Humanos , Volume Sistólico , Sístole , Função Ventricular Esquerda
17.
Clin Exp Allergy ; 50(4): 453-462, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31955479

RESUMO

BACKGROUND: Children with asthma, even those with severe persistent disease, can have forced expiratory volume in 1 second (FEV1 ) values ≥100% of predicted, while others have diminished FEV1 . OBJECTIVE: We sought to characterize the lung mechanical properties underlying these two asthma phenotypes and the mechanisms explaining the paradox of severe asthmatic children, whom when clinically stable can have an FEV1 >100% of predicted, but during an acute bronchospastic episode can experience a life-threatening asthma event. METHODS: Lung mechanics were evaluated in three groups of children: asthmatics with FEV1 ≥100% (HFEV1 ; n = 13), asthmatics with FEV1 ≤80% (LFEV1 ; n = 14) and non-asthmatic controls (n = 10). A linear mixed model was used to examine the relationship between volume and static transpulmonary pressures obtained at total lung capacity (TLC); actual TLC %of predicted and flow; and static transpulmonary pressure and flow. RESULTS: HFEV1 asthmatics had larger airways (FEV1 z-scores 1.12 vs -2.37; P < .05), greater lung volumes (mean % of predicted TLC 134.8% vs 109.6%; P < .05) and lower airway resistance (mean %of predicted Raw 101.9% vs 199.9%; P < .05) compared to the LFEV1 group. Moreover, HFEV1 asthmatics had significantly reduced elastic recoil pressure (pressure-volume curve shifted upward and to the left) and higher lung compliance (0.21 vs 00.9 L/cm H2 O; P < .05) compared to the LFEV1 group. The pressure-flow curves revealed the LFEV1 group to have significantly increased resistance to flow in the upstream segment of the airways at all lung volumes studied compared to HFEV1 . CONCLUSION AND CLINICAL RELEVANCE: HFEV1 asthmatic children display distinct lung mechanical proprieties compared to their LFEV1 asthmatic peers. With loss of elastic recoil pressure, the HFEV1 group could generate normal FEV1 due to proportionally enlarged airways and reduced airway resistance, while airflow limitation in the LFEV1 is due to increased airway resistance. Loss of elastic recoil and interdependence during acute bronchoconstriction episodes may predispose the HFEV1 group to catastrophic reductions in airflow.


Assuntos
Asma/fisiopatologia , Pulmão/fisiopatologia , Mecânica Respiratória , Adolescente , Criança , Feminino , Volume Expiratório Forçado , Humanos , Masculino
18.
Catheter Cardiovasc Interv ; 96(7): 1522-1530, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32427426

RESUMO

BACKGROUND: Transcatheter aortic valves are prone to acute recoil similar to the metal-based coronary stents. However, it is not clear if recoil remains a factor only after the initial valve deployment or also after post-dilation. METHODS: We conducted a retrospective observational study of patients who underwent transfemoral transcatheter aortic valve replacement (TAVR) with SAPIEN-3 valve. Acute recoil at the upper, central, and lower levels of the valve was calculated in both anteroposterior right anterior oblique (RAO) and lateral left anterior oblique (LAO) views after initial deployment as well as after post-dilation. The average recoil of the RAO and LAO views was also calculated and described as RAO/LAO. RESULTS: The acute recoil in the RAO/LAO views (mean ± SD) was 3.9 ± 1.1% after valve deployment in the whole study population (n = 257). Among the subset of patients who required post-dilation (n = 133), the mean acute recoil in the RAO/LAO views was found to be greater after initial valve deployment as compared with after post-dilation (3.8 ± 1.1% vs. 3.0 ± 0.9%; p < .001). Further, acute recoil was significantly greater in the RAO view than the LAO view and at the central level of the prosthesis as compared with the upper and lower levels. Those findings were consistent after initial deployment as well as after post-dilation. Clinical outcomes were similar between patients who required post-dilation compared to those who did not. In multivariable logistic regression analysis, only smaller valve cover index was found to be an independent predictor of 30-day mild or greater aortic regurgitation (OR 0.007; 95% CI 0.0001-0.707; p = .035). CONCLUSION: Acute elastic recoil of the SAPIEN-3 valve was significantly less after post-dilation as compared with after deployment. It was also greater when measured in the RAO view as compared with the LAO view. Furthermore, acute recoil was not homogenous across the height of the valve stent frame.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Cateterismo Periférico , Artéria Femoral , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Cateterismo Periférico/efeitos adversos , Elasticidade , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 95(2): 226-231, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31033171

RESUMO

OBJECTIVES: To assess the performance of the commercially available Magmaris sirolimus-eluting bioresorbable scaffold (BRS) with invasive imaging at different time points. BACKGROUND: Coronary BRS with a magnesium backbone have been recently studied as an alternative to polymeric scaffolds, providing enhanced vessel support and a faster resorption rate. We aimed to assess the performance of the commercially available Magmaris sirolimus-eluting BRS at different time points. METHODS: A prospective, single-center, nonrandomized study was performed at the Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands. Six patients with stable de novo coronary artery lesions underwent single-vessel revascularization with the Magmaris sirolimus-eluting BRS. Invasive follow-up including intravascular imaging using optical coherence tomography (OCT) was performed at different time points. RESULTS: At a median of 8 months (range 4-12 months) target lesion failure occurred in one patient. Angiography revealed a late lumen loss of 0.59 ± 0.39 mm, a percentage diameter stenosis of 39.65 ± 15.81%, and a binary restenosis rate of 33.3%. OCT showed a significant reduction in both minimal lumen area (MLA) and scaffold area at the site of the MLA by 43.44 ± 28.62 and 38.20 ± 25.74%, respectively. A fast and heterogeneous scaffold degradation process was found with a significant reduction of patent struts at 4-5 months. CONCLUSIONS: Our findings show that the latest iteration of magnesium BRS suffers from premature dismantling, resulting in a higher than expected decrease in MLA.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Magnésio/química , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
20.
J Endovasc Ther ; 27(4): 547-564, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32571125

RESUMO

Endovascular revascularization has been increasingly utilized to treat patients with chronic limb-threatening ischemia (CLTI), particularly atherosclerotic disease in the infrapopliteal arteries. Lesions of the infrapopliteal arteries are the result of 2 different etiologies: medial calcification and intimal atheromatous plaque. Although several devices are available for endovascular treatment of infrapopliteal lesions, balloon angioplasty still comprises the mainstay of therapy due to a lack of purpose-built devices. The mechanism of balloon angioplasty consists of adventitial stretching, medial necrosis, and dissection or plaque fracture. In many cases, the diffuse nature of infrapopliteal disease and plaque complexity may lead to dissection, recoil, and early restenosis. Optimal balloon angioplasty requires careful attention to assessment of vessel calcification, appropriate vessel sizing, and the use of long balloons with prolonged inflation times, as outlined in a treatment algorithm based on this systematic review. Further development of specific devices for this arterial segment are warranted, including devices for preventing recoil (eg, dedicated atherectomy devices), treating dissections (eg, tacks, stents), and preventing neointimal hyperplasia (eg, novel drug delivery techniques and drug-eluting stents). Further understanding of infrapopliteal disease, along with the development of new technologies, will help optimize the durability of endovascular interventions and ultimately improve the limb-related outcomes of patients with CLTI.


Assuntos
Algoritmos , Angioplastia com Balão , Técnicas de Apoio para a Decisão , Isquemia/terapia , Doença Arterial Periférica/terapia , Artéria Poplítea , Amputação Cirúrgica , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Angioplastia com Balão/mortalidade , Doença Crônica , Tomada de Decisão Clínica , Humanos , Isquemia/diagnóstico por imagem , Isquemia/mortalidade , Isquemia/fisiopatologia , Salvamento de Membro , Seleção de Pacientes , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/mortalidade , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Recidiva , Fatores de Risco , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa