RESUMO
Enzymes that phosphorylate, dephosphorylate, and ligate RNA 5' and 3' ends were discovered more than half a century ago and were eventually shown to repair purposeful site-specific endonucleolytic breaks in the RNA phosphodiester backbone. The pace of discovery and characterization of new candidate RNA repair activities in taxa from all phylogenetic domains greatly exceeds our understanding of the biological pathways in which they act. The key questions anent RNA break repair in vivo are (a) identifying the triggers, agents, and targets of RNA cleavage and (b) determining whether RNA repair results in restoration of the original RNA, modification of the RNA (by loss or gain at the ends), or rearrangements of the broken RNA segments (i.e., RNA recombination). This review provides a perspective on the discovery, mechanisms, and physiology of purposeful RNA break repair, highlighting exemplary repair pathways (e.g., tRNA restriction-repair and tRNA splicing) for which genetics has figured prominently in their elucidation.
Assuntos
RNA Ligase (ATP) , RNA , Filogenia , RNA Ligase (ATP)/genética , RNA Ligase (ATP)/metabolismo , RNA/genética , RNA de Transferência/genética , RNA de Transferência/metabolismo , Splicing de RNA/genéticaRESUMO
Ribonucleotides in DNA cause several types of genome instability and can be removed by ribonucleotide excision repair (RER) that is finalized by DNA ligase 1 (LIG1). However, the mechanism by which LIG1 discriminates the RER intermediate containing a 5'-RNA-DNA lesion generated by RNase H2-mediated cleavage of ribonucleotides at atomic resolution remains unknown. Here, we determine X-ray structures of LIG1/5'-rG:C at the initial step of ligation where AMP is bound to the active site of the ligase and uncover a large conformational change downstream the nick resulting in a shift at Arg(R)871 residue in the Adenylation domain of the ligase. Furthermore, we demonstrate a diminished ligation of the nick DNA substrate with a 5'-ribonucleotide in comparison to an efficient end joining of the nick substrate with a 3'-ribonucleotide by LIG1. Finally, our results demonstrate that mutations at the active site residues of the ligase and LIG1 disease-associated variants significantly impact the ligation efficiency of RNA-DNA heteroduplexes harboring "wrong" sugar at 3'- or 5'-end of nick. Collectively, our findings provide a novel atomic insight into proficient sugar discrimination by LIG1 during the processing of the most abundant form of DNA damage in cells, genomic ribonucleotides, during the initial step of the RER pathway.
Assuntos
DNA Ligase Dependente de ATP , Reparo do DNA , DNA , RNA , DNA Ligase Dependente de ATP/metabolismo , DNA Ligase Dependente de ATP/química , DNA Ligase Dependente de ATP/genética , Humanos , DNA/metabolismo , DNA/química , RNA/metabolismo , RNA/química , RNA/genética , Ribonucleotídeos/metabolismo , Ribonucleotídeos/química , Domínio Catalítico , Cristalografia por Raios X , Ribonuclease H/metabolismo , Ribonuclease H/química , Reparo por ExcisãoRESUMO
Human DNA ligase 1 (LIG1) is the main replicative ligase that seals Okazaki fragments during nuclear replication and finalizes DNA repair pathways by joining DNA ends of the broken strand breaks in the three steps of the ligation reaction. LIG1 can tolerate the RNA strand upstream of the nick, yet an atomic insight into the sugar discrimination mechanism by LIG1 against a ribonucleotide at the 3'-terminus of nick DNA is unknown. Here, we determined X-ray structures of LIG1/3'-RNA-DNA hybrids and captured the ligase during pre- and post-step 3 the ligation reaction. Furthermore, the overlays of 3'-rA:T and 3'-rG:C step 3 structures with step 2 structures of canonical 3'-dA:T and 3'-dG:C uncover a network of LIG1/DNA interactions through Asp570 and Arg871 side chains with 2'-OH of the ribose at nick showing a final phosphodiester bond formation and the other ligase active site residues surrounding the AMP site. Finally, we demonstrated that LIG1 can ligate the nick DNA substrates with pre-inserted 3'-ribonucleotides as efficiently as Watson-Crick base-paired ends in vitro. Together, our findings uncover a novel atomic insight into a lack of sugar discrimination by LIG1 and the impact of improper sugar on the nick sealing of ribonucleotides at the last step of DNA replication and repair.
Assuntos
DNA Ligase Dependente de ATP , DNA , Ribonucleotídeos , Humanos , DNA Ligase Dependente de ATP/metabolismo , DNA Ligase Dependente de ATP/genética , DNA Ligase Dependente de ATP/química , DNA/metabolismo , DNA/química , Ribonucleotídeos/metabolismo , Ribonucleotídeos/química , Cristalografia por Raios X , Reparo do DNARESUMO
Sealing wet porous membranes is a major challenge when fabricating cell encapsulation devices. Herein, we report the development of an Autoclavable Transparent Thermal Cutter (ATTC) for reliably sealing wet nanofibrous membranes. Notably, the ATTC is autoclavable and transparent, thus enabling in situ visualization of the sealing process in a sterile environment and ensuring an appropriate seal. In addition, the ATTC could generate smooth, arbitrary-shaped sealing ends with excellent mechanical properties when sealing PA6, PVDF, and TPU nanofibrous tubes and PP microporous membranes. Importantly, the ATTC could reliably seal wet nanofibrous tubes, which can shoulder a burst pressure up to 313.2 ± 19.3 kPa without bursting at the sealing ends. Furthermore, the ATTC sealing process is highly compatible with the fabrication of cell encapsulation devices, as verified by viability, proliferation, cell escape, and cell function tests. We believe that the ATTC could be used to reliably seal cell encapsulation devices with minimal side effects.
RESUMO
Developing high electroactivity ruthenium (Ru)-based electrocatalysts for pH-universal hydrogen evolution reaction (HER) is challenging due to the strong bonding strengths of key RuâH/RuâOH intermediates and sluggish water dissociation rates on active Ru sites. Herein, a semi-ionic F-modified N-doped porous carbon implanted with ruthenium nanoclusters (Ru/FNPC) is introduced by a hydrogel sealing-pyrolying-etching strategy toward highly efficient pH-universal hydrogen generation. Benefiting from the synergistic effects between Ru nanoclusters (Ru NCs) and hierarchically F, N-codoped porous carbon support, such synthesized catalyst displays exceptional HER reactivity and durability at all pH levels. The optimal 8Ru/FNPC affords ultralow overpotentials of 17.8, 71.2, and 53.8 mV at the current density of 10 mA cm-2 in alkaline, neutral, and acidic media, respectively. Density functional theory (DFT) calculations elucidate that the F-doped substrate to support Ru NCs weakens the adsorption energies of H and OH on Ru sites and reduces the energy barriers of elementary steps for HER, thus enhancing the intrinsic activity of Ru sites and accelerating the HER kinetics. This work provides new perspectives for the design of advanced electrocatalysts by porous carbon substrate implanted with ultrafine metal NCs for energy conversion applications.
RESUMO
The absorbent expansion elastomer plays a crucial role in engineering sealing and holds a promising future in this field as infrastructure continues to develop. Traditional materials have their limitations, especially when used in large construction projects where the integrity and reliability of the material are of utmost importance. In this work, a self-healing water-absorbing expansion elastomer was developed for continuous production at a large scale to monitor the sealing conditions of massive infrastructure projects. At room temperature, the material exhibited a repairing efficiency of 57.77 % within 2â h, which increased to 84.02 % after 12â h. This extended reaction time allowed for effective repairs when defects were detected. The material's strength can attain 3â MPa, placing it at the upper echelon among common self-healing materials, thereby granting it a certain level of durability in its application environment. The material's volume expansion rate reached 200-400 % to achieve effective sealing, and the functional filling of the filler endowed the material itself with a favorable external force induction effect and prevented heat accumulation. The conductive detection performance of the absorbent expansion elastomer was improved by utilizing triple self-healing strategies, including dipole-dipole interaction, ion cross-linked network, and externally-aided restoration materials. These strategies were combined with a double packing strategy to enhance the material's properties. This innovative elastomer can be applied in various fields such as tunnel construction, infrastructure development, aerospace sealing, and railway transportation, showcasing significant potential for diverse engineering applications.
RESUMO
DNA ligase (LIG) I and IIIα finalize base excision repair (BER) by sealing a nick product after nucleotide insertion by DNA polymerase (pol) ß at the downstream steps. We previously demonstrated that a functional interplay between polß and BER ligases is critical for efficient repair, and polß mismatch or oxidized nucleotide insertions confound the final ligation step. Yet, how targeting downstream enzymes with small molecule inhibitors could affect this coordination remains unknown. Here, we report that DNA ligase inhibitors, L67 and L82-G17, slightly enhance hypersensitivity to oxidative stress-inducing agent, KBrO3, in polß+/+ cells more than polß-/- null cells. We showed less efficient ligation after polß nucleotide insertions in the presence of the DNA ligase inhibitors. Furthermore, the mutations at the ligase inhibitor binding sites (G448, R451, A455) of LIG1 significantly affect nick DNA binding affinity and nick sealing efficiency. Finally, our results demonstrated that the BER ligases seal a gap repair intermediate by the effect of polß inhibitor that diminishes gap filling activity. Overall, our results contribute to understand how the BER inhibitors against downstream enzymes, polß, LIG1, and LIGIIIα, could impact the efficiency of gap filling and subsequent nick sealing at the final steps leading to the formation of deleterious repair intermediates.
Assuntos
DNA Ligase Dependente de ATP , DNA Polimerase beta , Reparo do DNA , DNA Polimerase beta/metabolismo , Reparo do DNA/efeitos dos fármacos , DNA Ligase Dependente de ATP/genética , DNA Ligase Dependente de ATP/metabolismo , Humanos , DNA Ligases/metabolismo , Bromatos/farmacologia , Inibidores Enzimáticos/farmacologia , Animais , Estresse Oxidativo/efeitos dos fármacos , Camundongos , Proteínas de Ligação a Poli-ADP-Ribose/genética , Proteínas de Ligação a Poli-ADP-Ribose/metabolismo , Dano ao DNA/efeitos dos fármacos , DNA/metabolismo , Reparo por ExcisãoRESUMO
PURPOSE: This technical note presents a case of a patient with a failed Nellix device (Endologix, Irvine, Calif) who was not deemed fit for open conversion. Our planned approach for repair involved an endovascular procedure utilizing a custom-made branched device. TECHNIQUE: An endovascular repair was performed via a custom-made four outer branched device in conjunction with a custom-made bifurcated graft featuring inverted limbs (Cook Inc., Bloomington, Ind). All branches were connected to the target vessel with Gore Viabahn VBX balloon-expandable covered stents (Gore & Associates Inc.). CONCLUSION: Endovascular conversion with branched endovascular repair in a patient not deemed fit for open surgery was successfully performed, thereby reducing the risk of a high morbid and mortal procedure. CLINICAL IMPACT: Novel useful treatment solution of failed EVAR with Nellix device.
RESUMO
Adhesive dentistry has made it feasible to design restorations with high aesthetic qualities and little invasiveness. However, the freshly cut dentin after the tooth preparation needs to be sealed to prevent its contaminations, bacterial leakage, and hypersensitivity. Consequently, the immediate dentin sealing (IDS) method has been advised. This study examines different dentinal tubule sealing methods via CO2 laser, diode laser (980-nm) and a two-step self-etch adhesive system applied directly to the fresh cut dentin preceding the placement of the provisional phase. The sealing efficiency of each laser and bond system was evaluated based on the laser-induced fluorescence (LIF) properties and image analysis by scanning electron microscopy. Moreover, the obtained LIF spectra were evaluated using partial least square progression. A two-step adhesive containing a high concentration of S-PRG fillers produced a thick layer that was not perfectly uniform at all sites due to uneven filler distribution in the bond with totally and partially closed dentinal tubules. However, the peaks of the LIF spectra dropped after applying laser because of its sealing effectiveness. Accordingly, CO2 and diode lasers have strong evidence in dentinal tubule sealing and a definitive treatment modality for dentinal hypersensitivity. Moreover, IDS with an adhesive system is superior in occluding dentinal tubules in a biomimetic manner based on its filler content and bioactive properties.
RESUMO
Sealing faults are nearly impermeable barriers that can form boundaries between subsurface pore-pressure domains. In hydrocarbon systems, sealing faults commonly form part of a structural trap; they are thus important elements for future storage of CO2 and other gases in depleted reservoirs. The Triassic Montney Formation in western Canada hosts low-permeability gas reservoirs containing sealing faults that have previously been assumed to compartmentalize pressure domains. In this study, we show that the distribution of induced seismicity associated with hydraulic fracturing (HF) exhibits a statistically significant spatial correlation with zones of high lateral gradient in pore pressure. These high-gradient zones are interpreted as sealing fault systems. The largest induced seismicity sequence, including a 4.5 ML mainshock on 30 November 2018, occurred during HF treatments in two horizontal wells, between which there is an exceptionally large contrast (~10 MPa) in measured pore pressure. Numerical simulation of a simplified model of a hydraulic fracture intersecting a nearby vertical fault, followed by fault rupture using rate-and-state friction rheology, generates results that are in good agreement with observed strike-slip faulting near one of the HF wells. Our study demonstrates that sealing faults exhibit previously unrecognized behaviour that may be important for understanding induced seismicity risk. This article is part of the theme issue 'Induced seismicity in coupled subsurface systems'.
RESUMO
Anisotropic gold nanostructures have gained increased attention for biomedical applications because of their remarkable optical properties. An emerging type of gold nanostructure-gold nanobipyramids (AuNBP)-has been shown to exhibit superior absorption properties compared to conventionally used gold nanoparticles, which makes them attractive for photothermal applications. We generated a high-shape-purity dispersion of AuNBP using a seed-mediated method and embedded them as photothermal conversion agents in a silk fibroin matrix to investigate their efficacy in photothermal sealing of incisional wounds in immunocompetent mice. These AuNBP-doped laser-activated sealants, or AuNBP-LASE were able to absorb near-infrared laser energy and convert it to heat, thereby inducing transient hyperthermia in the wound and the surrounding tissue. This photothermal conversion facilitated rapid sealing of the skin tissue by the AuNBP-LASE, which resulted in faster functional recovery of skin barrier function compared to nylon sutures at the early stages of repair. Further, the biomechanical properties of the healing skin closed with AuNBP-LASE those of intact skin more rapidly compared to incisions approximated with sutures. Histology studies indicated higher penetration of the LASE within the volume of the incision in skin tissue, lower scab formation, and a similar epidermal gap compared to conventional suturing. These results demonstrate that AuNBP-LASEs can be effective as wound approximation devices for photothermal sealing.
Assuntos
Hipertermia Induzida , Nanopartículas Metálicas , Camundongos , Animais , Ouro/uso terapêutico , Nanopartículas Metálicas/uso terapêutico , Nanopartículas Metálicas/química , Pele , LasersRESUMO
Objective. CoolSeal is a new vessel sealing system for dissection and hemostasis during surgery. No clinical studies have investigated safety, advantages or disadvantages regarding the use of this device. The aim of the present study was to investigate the safety of CoolSeal and compare it with conventional ligation technique or LigaSure during the total thyroidectomy. We hypothesized that the use of CoolSeal would reduce the operating time and bleeding without complications increase. Study design represents a retrospective cohort study with a tertiary reference center setting. Methods. We analyzed total thyroidectomy data from January 2021 to June 2023. We recorded patients' characteristics, surgical information, and postoperative outcome. Results. We performed 221 total thyroidectomies in the study period. Analysis was restricted to 171 patients operated by only two surgeons. Hemostasis was secured by conventional ligation in 117 patients (68%), LigaSure in 34 patients (20%) and CoolSeal in 20 patients (12%). Median thyroid weight and bleeding were 67 g and 50 ml, respectively. Procedures using LigaSure or Cool-Seal were on larger glands (median 205 g) without increased bleeding (50 ml). Operating time was shortest with CoolSeal (96 min, p=0.003) compared with LigaSure (117 min) or conventional ligation (115 min). Bleeding was reduced with CoolSeal compared with LigaSure (45 vs. 100 ml, p=0.003). With CoolSeal, median hospitalization was one postoperative day, no patients required re-operation. There was no palsy of recurrent laryngeal nerves and no permanent hypoparathyroidism. Conclusion. In our first clinical experience, CoolSeal was safe and efficient for total thyroidectomy. With a small sample size, we saw a clinical benefit with reduced operating time without post-operative complications increase.
Assuntos
Perda Sanguínea Cirúrgica , Hemostasia Cirúrgica , Duração da Cirurgia , Tireoidectomia , Humanos , Tireoidectomia/métodos , Tireoidectomia/instrumentação , Tireoidectomia/efeitos adversos , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Hemostasia Cirúrgica/instrumentação , Hemostasia Cirúrgica/métodos , Perda Sanguínea Cirúrgica/prevenção & controle , Idoso , Ligadura/instrumentação , Ligadura/métodos , Resultado do TratamentoRESUMO
In this study, we evaluated the effect of four different strategies for bonding a CAD/CAM resin nanoceramic restoration (Lava Ultimate, 3M) to the dentin surface using a universal adhesive (Scotch Bond Universal, 3M) and adhesive resin cement (RelyX Ultimate, 3M) on the shear bond strength (SBS) and failure mode. The strategies comprised: (i) immediate sealing, immediate bonding; (ii) immediate sealing, bonding after 2 weeks with provisional restoration; (iii) immediate sealing with flowable resin composite reinforcement and bonding after 2 weeks with provisional restoration; and (iv) no immediate sealing, and bonding after 2 weeks with provisional restoration. After bonding, all the specimens were thermocycled, shear tests were performed using a universal testing machine, and failure modes were determined using stereomicroscope and scanning electron microscopy. The highest mean SBS was recorded with immediate sealing, immediate bonding strategy. Most adhesive failures with exposed dentinal tubules were noted in specimens exposed to bonding after 2 weeks with no immediate sealing, which was associated with the lowest SBS. Mixed failures predominated in all immediate dentin sealing groups. Immediate sealing with universal adhesives improves SBS, particularly in the single-visit approach, which has shown significantly better performance, whereas the provisional phase has a negative effect.
Assuntos
Resinas Compostas , Colagem Dentária , Análise do Estresse Dentário , Adesivos Dentinários , Cimentos de Resina , Resistência ao Cisalhamento , Resinas Compostas/química , Colagem Dentária/métodos , Humanos , Cimentos de Resina/química , Adesivos Dentinários/química , Dentina , Microscopia Eletrônica de Varredura , Teste de Materiais , Restauração Dentária Permanente/métodos , Cerâmica/química , Desenho Assistido por Computador , Propriedades de Superfície , Falha de Restauração DentáriaRESUMO
BACKGROUND: Computed tomography (CT)-guided lung biopsy is a widely used technique for the diagnosis of pulmonary lesions and with a high technical success rate and diagnostic accuracy. On the other hand, it is associated with a high risk of complications, especially pneumothorax. Various methods have been tried to reduce the incidence of pneumothorax, but no established method exists. The purpose of this study was to evaluate whether the combination of tract sealing with normal saline and rapid rollover can reduce the rate of pneumothorax and chest tube insertion after CT-guided lung biopsy. METHODS: We reviewed all CT-guided lung biopsies performed at a single institution between October 2016 and December 2021. Before August 2019, no specific additional techniques were employed to mitigate complications (Group 1). In contrast, after September 2019, normal saline for tract sealing was injected during needle removal, and if pneumothorax was observed during the intervention, the patient was rolled over into the puncture-site down position immediately after needle removal (Group 2). The rate of complications was compared between the two groups. RESULTS: 130 patients in Group 1 and 173 in Group 2 were evaluated. There was no significant difference in pneumothorax rate between the two groups (30.0% vs. 23.1%, P = .177). A chest tube was inserted in 10 of 130 patients in Group 1 and only in 1 of 173 in Group 2 (P = .001). There were no complications associated with this combinational technique. CONCLUSIONS: The combination of normal saline injection and rapid rollover significantly reduced the incidence of pneumothorax requiring chest tube insertion after CT-guided lung biopsy. Therefore, normal saline injection and rapid rollover can serve as a preventive method for severe pneumothorax in CT-guided lung biopsy.
Assuntos
Biópsia Guiada por Imagem , Pulmão , Pneumotórax , Solução Salina , Tomografia Computadorizada por Raios X , Humanos , Pneumotórax/prevenção & controle , Pneumotórax/etiologia , Pneumotórax/epidemiologia , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Idoso , Incidência , Pulmão/patologia , Pulmão/diagnóstico por imagem , Solução Salina/administração & dosagem , Adulto , Tubos TorácicosRESUMO
PURPOSE: Cerebrospinal fluid (CSF) leakage is a challenging complication of intradural cranial surgery, and children are particularly at risk. The use of dural sealants confers protection in adults, but pediatric studies are scarce. We evaluated the safety and efficacy of Evicel® fibrin sealant as an adjunct to primary dural suturing in children undergoing cranial surgery. METHODS: A multicenter trial prospectively enrolled pediatric subjects (< 18 years) undergoing cranial neurosurgery who, upon completion of primary sutured dural repair, experienced CSF leakage. As agreed by the EMA Evicel® Pediatric Investigation Plan, 40 subjects were intra-operatively randomized 2:1 to Evicel® or additional sutures ('Sutures'). Data analysis was descriptive. The efficacy endpoint was treatment success rate, with success defined as intra-operative watertight closure after provocative Valsalva maneuver (primary endpoint). Safety endpoints were postoperative CSF leakage (incisional CSF leakage, pseudomeningocele or both) and surgical site complications (secondary endpoints). RESULTS: Forty subjects (0.6-17 years) were randomized to Evicel® (N = 25) or Sutures (N = 15) (intention-to-treat). Intracranial tumor was the most common indication and procedures were mostly supratentorial craniotomies. Success rates were 92.0% for Evicel® and 33.3% for Sutures, with a 2.76 estimated ratio of success rates (Farrington-Manning 95% CI [1.53, 6.16]). Sensitivity analyses in per-protocol and safety sets showed similar results. Despite a higher rescue treatment rate, the frequencies of postoperative CSF leakage and wound complications were higher for Sutures than for Evicel®. CONCLUSION: This small-scale prospective study shows Evicel® treatment to be safe and effective as an adjunct to primary sutured dura mater closure in a pediatric population. Compared to additional sutures, Evicel® was associated with reduced postoperative CSF leakage and surgical site complications. (Trial registration: The trial was registered as NCT02309645 and EudraCT 2013-003558-26).
Assuntos
Vazamento de Líquido Cefalorraquidiano , Dura-Máter , Adesivo Tecidual de Fibrina , Procedimentos Neurocirúrgicos , Humanos , Adesivo Tecidual de Fibrina/uso terapêutico , Feminino , Masculino , Criança , Pré-Escolar , Adolescente , Lactente , Procedimentos Neurocirúrgicos/métodos , Dura-Máter/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Resultado do Tratamento , Adesivos Teciduais/uso terapêutico , Estudos Prospectivos , Técnicas de SuturaRESUMO
Electrosurgical and ultrasonic devices are used in surgical procedures for hemostatic sealing and bisection of vascular tissues. Previous benchtop studies alternatively demonstrated successful infrared laser sealing and cutting of blood vessels, in a sequential, two-step approach. This study describes a smaller, laparoscopic device compatible design, and simultaneous approach to sealing and bisection of vessels, with potential optical feedback. A 1470-nm infrared diode laser sealed and bisected 40 porcine renal arteries, ex vivo. A reciprocating, side-firing, optical fiber, housed in a transparent square quartz optical chamber (2.7 × 2.7 × 25 mm outer dimensions), delivered laser energy over an 11 mm scan length, with a range of incident powers (41-59 W) and treatment times (5-21 s). Vessel diameters ranged from 2.5 to 4.8 mm. Vessel burst pressure measurements were performed on each cut end (n = 80) with success indicated by pressures exceeding 360 mmHg. All vessel ends were successfully sealed and bisected (80/80). The highest incident power, 59 W, yielded short treatment times of 5-6 s. Peak temperatures on the external chamber surface reached 103 oC. Time to cool down to body temperature measured 37 s. Infrared lasers simultaneously seal and bisect blood vessels, with treatment times comparable to, and temperatures and cooling times lower than reported for conventional devices. Future work will focus on integrating the fiber and chamber into a standard 5-mm-outer-diameter laparoscopic device. Customization of fiber scan length to match vessel size may also reduce laser energy deposition, enabling lower peak temperatures, treatment times, and cooling times.
Assuntos
Lasers Semicondutores , Artéria Renal , Animais , Lasers Semicondutores/uso terapêutico , Suínos , Artéria Renal/cirurgia , Raios Infravermelhos , Hemostasia Cirúrgica/instrumentação , Hemostasia Cirúrgica/métodos , Terapia a Laser/instrumentação , Terapia a Laser/métodos , Laparoscopia/métodos , Laparoscopia/instrumentaçãoRESUMO
PURPOSE: To compare conventional bipolar electrosurgery with advanced bipolar vessel sealing (ABVS) devices for total laparoscopic hysterectomy (TLH). METHODS: A systematic review was conducted by searching Scopus, PubMed/MEDLINE, ScienceDirect, and Cochrane Library from January 1989 to November 2021. We identified all studies comparing ABVS devices with conventional bipolar electrosurgery in TLH and reporting at least one of the following outcomes: total blood loss, total operative time, hospital stay, perioperative complications, or costs. Meta-analysis was conducted with a random effect model reporting pooled mean differences and odds ratios (ORs) with related 95% confidence intervals (CIs). RESULTS: Two randomized controlled trials and two retrospective studies encompassing 314 patients were included out of 615 manuscripts. The pooled estimated total blood loss in the ABVS devices group was lower than conventional bipolar electrosurgery of 39 mL (95% CI - 65.8 to - 12.6 mL; p = .004). The use of ABVS devices significantly reduced the total operative time by 8 min (95% CI - 16.7 to - 0.8 min; p = .033). Hospital stay length did not differ between the two groups, and a comparable overall surgical complication rate was observed [OR of 0.9 (95% CI 0.256 - 3.200; p = .878]. CONCLUSIONS: High-quality evidence comparing ABVS devices with conventional bipolar electrosurgery for TLH is lacking. ABVS devices were associated with reduced total blood loss and operative time; however, observed differences seem clinically irrelevant. Further research is required to clarify the advantages of ABVS devices over conventional bipolar electrosurgery and to identify cases that may benefit more from their use.
Assuntos
Laparoscopia , Feminino , Humanos , Estudos Retrospectivos , Laparoscopia/efeitos adversos , Eletrocirurgia , Histerectomia/efeitos adversos , Duração da Cirurgia , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
OBJECTIVES: To investigate in vitro effects of a nanoparticle bioceramic material, iRoot BP Plus, on stem cells from apical papilla (SCAP) and in vivo capacity to induce pulp-dentin complex formation. MATERIALS AND METHODS: The sealing ability of iRoot BP Plus was measured via scanning electron microscopy (SEM). SCAP were isolated and treated in vitro by iRoot BP Plus conditioned medium, with mineral trioxide aggregate (MTA) conditioned medium and regular medium used as controls, respectively. Cell proliferation was assessed by BrdU labeling and MTT assay and cell migration was evaluated with wound healing and transwell assays. Osteo/odontogenic potential was evaluated by Alizarin red S staining and qPCR. Pulp-dentin complex formation in vivo was assessed by a tooth slice subcutaneous implantation model. RESULTS: iRoot BP Plus was more tightly bonded with the dentin. There was no difference in SCAP proliferation between iRoot BP Plus and control groups (P > 0.05). iRoot BP Plus had a greater capacity to elevated cell migration (P < 0.05) and osteo/odontogenic marker expression and mineralization nodule formation of SCAP compared with MTA groups (P < 0.05). Furthermore, the new continuous dentine layer and pulp-like tissue was observed in the iRoot BP Plus group in vivo. CONCLUSIONS: iRoot BP Plus showed excellent sealing ability, promoted the migration and osteo/odontogenesis of SCAP and induced pulp-dentin complex formation without affecting the cell proliferation, which indicated iRoot BP Plus was a promising coronal sealing material in REPs. CLINICAL RELEVANCE: The coronal sealing materials play crucial roles for the outcomes of REPs. This study showed that iRoot BP Plus has good coronal sealing and promote pulp-dentin complex formation compared with MTA, providing experimental evidences for the clinical application of iRoot BP Plus as a promising coronal seal material in REPs.
Assuntos
Endodontia Regenerativa , Humanos , Meios de Cultivo Condicionados/farmacologia , Diferenciação Celular , Polpa Dentária , Silicatos/farmacologia , Proliferação de Células , Óxidos/farmacologia , Compostos de Cálcio/farmacologia , Combinação de Medicamentos , Compostos de Alumínio/farmacologiaRESUMO
DECLARATION OF INTEREST: The authors have no conflicts of interest.
Assuntos
Nocardiose , Úlcera , Humanos , Cicatrização , Nocardiose/complicações , Nocardiose/diagnósticoRESUMO
A transparent and adhesive film-based enclosing and sealing method is here presented for out-of-cleanroom-based open-form microfluidic devices. The commercially available polyester flexible film known as Microseal 'B' is presented in this paper as a cover seal for open-form microfluidic devices. This film is adaptable to high working temperatures and is biocompatible. The quality of the sealing film was investigated by leak tests, fluorescence tests, and contact angle measurements. The investigations revealed its sealing strength, fluorescence detection compatibility, and surface wettability. It was found that the proposed sealing polyester film on the 3D-printed device could sustain a gauge pressure of 2.7 atm at a flow rate of 4 mL/min without any leaks. It also provided fluorescence detection compatibility and an intensity-to-background ratio in the range of 2.3 to 4.5 for particle sizes of 5 µm and 15 µm, respectively, which is comparable with the performances of other sealing materials. The film's hydrophobicity is comparable to other polymers used in microfluidics. This paper concludes by showcasing some applications of such transparent tops in classical microfluidic devices used for droplet generation and fluid mixing, in order to demonstrate the prospects of this fabrication technique in lab-on-a-chip devices.