Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Nucl Cardiol ; 25(1): 181-190, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-27580616

RESUMO

BACKGROUND: Technetium pyrophosphate (99mTc-PYP) imaging to diagnose transthyretin cardiac amyloidosis (ATTR-CA) has been increasingly utilized. The objective of this study is to provide a standardized 99mTc-PYP imaging protocol to diagnose ATTR-CA. METHODS: 104 scans from 45 subjects with biopsy-proven ATTR-CA or light-chain cardiac amyloidosis (AL) were assessed. Multiple scans were obtained using different counts (750 vs 2000 K), times to acquisition (1 vs 2 to 4 hours), processing matrix (256 vs 128), and 99mTc-PYP dose. Image quality and extracardiac activity was assessed. Quantitative methods using heart-to-contralateral ratios (H/CL) and a visual semiquantitative scale were used to diagnose ATTR-CA.19 The correlation between H/CL ratios and reproducibility of semiquantitative visual scores, acquired using various imaging parameters, were evaluated. RESULTS: All imaging parameters had good to excellent image quality. 750 vs 2000 K counts, 1 hour acquisition and 256 matrix, had lower extracardiac activity (P = .00018). 10 mCi of 99mTc-PYP v. higher doses showed excellent image quality and less extracardiac activity (P = .0015). Correlation of H/CL ratios was strong (r ≥ 0.92) and reproducibility of semiquantitative visual scores was high (Kappa = 95%). CONCLUSION: An imaging protocol using 750 K counts, 10 mCi of 99mTc-PYP, and a 256 matrix was chosen as the standardized imaging protocol since it provided the shortest overall study time (1 vs 2 to 4 hours) and lowest radiation exposure (3 vs 8 to 10 mSv).


Assuntos
Amiloidose/diagnóstico por imagem , Técnicas de Imagem Cardíaca/normas , Cardiomiopatias/diagnóstico por imagem , Pré-Albumina/metabolismo , Pirofosfato de Tecnécio Tc 99m , Idoso , Biópsia , Cardiologia/normas , Difosfonatos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Mutação , Imagem de Perfusão do Miocárdio/normas , Compostos de Organotecnécio , Estudos Prospectivos , Cintilografia , Reprodutibilidade dos Testes
2.
J Surg Oncol ; 112(1): 2-8, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26074273

RESUMO

BACKGROUND AND OBJECTIVE: Fluorescence-guided imaging to assist in identification of malignant margins has the potential to dramatically improve oncologic surgery. However, a standardized method for quantitative assessment of disease-specific fluorescence has not been investigated. Introduced here is a ratiometric threshold derived from mean fluorescent tissue intensity that can be used to semi-quantitatively delineate tumor from normal tissue. METHODS: Open-field and a closed-field imaging devices were used to quantify fluorescence in punch biopsy tissues sampled from primary tumors collected during a phase 1 trial evaluating the safety of cetuximab-IRDye800 in patients (n = 11) undergoing surgical intervention for head and neck cancer. Fluorescence ratios were calculated using mean fluorescence intensity (MFI) from punch biopsy normalized by MFI of patient-matched tissues. Ratios were compared to pathological assessment and a ratiometric threshold was established to predict presence of cancer. RESULTS: During open-field imaging using an intraoperative device, the threshold for muscle normalized tumor fluorescence was found to be 2.7, which produced a sensitivity of 90.5% and specificity of 78.6% for delineating disease tissue. The skin-normalized threshold generated greater sensitivity (92.9%) and specificity (81.0%). CONCLUSION: Successful implementation of a semi-quantitative threshold can provide a scientific methodology for delineating disease from normal tissue during fluorescence-guided resection of cancer.


Assuntos
Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/cirurgia , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/cirurgia , Cirurgia Assistida por Computador , Fluorescência , Humanos , Estadiamento de Neoplasias , Prognóstico , Curva ROC
3.
Clin Cardiol ; 42(2): 264-269, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30548264

RESUMO

BACKGROUND: Although left atrial appendage (LAA) anatomy and topographic relations are well understood, little is known about the impairment of neighboring structures (NBS) by an implanted left atrial appendage closure (LAAC) device. This prospective longitudinal observational study for the first time describes distances of implanted LAA closure (LAAC) devices to NBS using a standardized imaging protocol of cardiac computed tomography angiography (cCTA). HYPOTHESIS: cCTA imaging is an eligible tool for post-implantation evaluation of LAAC devices and their relation to neighboring structures. METHODS: cCTA data sets of consecutive patients 6 months after successful LAAC were acquired on a third generation dual-source CT system and reconstructed with a slice thickness of 0.5 mm. The standardized multi-planar reconstruction LAA occluder view for post-implantation evaluation (LOVE) algorithm was used to measure the distances to NBS in relation to LAA morphology and implanted LAAC devices. RESULTS: A total of 48 patients (median age 80 years, 25% female) were included. Left upper pulmonary vein and circumflex artery were generally closest to occlusion devices (median 2.9 and 2.8 mm, respectively). AMPLATZER AMULET devices were closer to the mitral valve annulus than WATCHMAN devices (6.6 mm (inter quartile range [IQR] 4.9-8.6) vs 10.9 mm (IQR 7.4-14.0), P = 0.001). Distances to the left upper pulmonary vein were affected by LAA morphology, with cauliflower type having the closest proximity (1.7 mm [IQR 1.0-3.4], P = 0.048). CONCLUSION: A standardized cCTA imaging protocol is an eligible tool to accurately measure distances to NBS. Left upper pulmonary vein and circumflex artery are closest to LAAC devices and could thus be most prone to impairment.


Assuntos
Algoritmos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Angiografia por Tomografia Computadorizada/métodos , Dispositivo para Oclusão Septal , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos
4.
Int J Cardiovasc Imaging ; 35(4): 725-731, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30421354

RESUMO

Cardiac computed tomography angiography (cCTA) has recently been proposed for evaluation of successful interventional left atrial appendage closure (LAA/LAAC). This prospective longitudinal observational study aims to assess this proposal by applying a standardized imaging protocol to detect and quantify peri-device leaks (PDL) after LAAC. cCTA datasets of consecutive patients 6 months after successful LAAC were acquired on a third generation dual-source computed tomography system and reconstructed with a slice thickness of 0.5 mm. The standardized multi-planar reconstruction LAA occluder view for post-implantation evaluation (LOVE) algorithm was used to assess PDL in relation to LAA morphology and implanted LAAC devices. A total of 49 patients (median age 80 years, 24% female) were included consecutively. Overall PDL rate was 31%. Leak rates among different left atrial appendage morphologies varied largely. Windsock type had the highest incidence of PDL (47%). AMPLATZER™ AMULET™ device type revealed slightly higher PDL rates than WATCHMAN™ type and showed larger leaks. However, no statistical differences were found. PDL can be sized best in LOVE sagittal views, whereas a synopsis of LOVE sagittal, axial and coronal views allows further examination and detection of small leaks. PDL are common after successful interventional LAAC, which can be accurately detected and sized by standardized cCTA imaging protocols.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/instrumentação , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Estudos Longitudinais , Masculino , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa