Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 421
Filtrar
1.
EMBO J ; 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39134659

RESUMO

Sex determination in animals is not only determined by karyotype but can also be modulated by environmental cues like temperature via unclear transduction mechanisms. Moreover, in contrast to earlier views that sex may exclusively be determined by either karyotype or temperature, recent observations suggest that these factors rather co-regulate sex, posing another mechanistic mystery. Here, we discovered that certain wild-isolated and mutant C. elegans strains displayed genotypic germline sex determination (GGSD), but with a temperature-override mechanism. Further, we found that BiP, an ER chaperone, transduces temperature information into a germline sex-governing signal, thereby enabling the coexistence of GGSD and temperature-dependent germline sex determination (TGSD). At the molecular level, increased ER protein-folding requirements upon increased temperatures lead to BiP sequestration, resulting in ERAD-dependent degradation of the oocyte fate-driving factor, TRA-2, thus promoting male germline fate. Remarkably, experimentally manipulating BiP or TRA-2 expression allows to switch between GGSD and TGSD. Physiologically, TGSD allows C. elegans hermaphrodites to maintain brood size at warmer temperatures. Moreover, BiP can also influence germline sex determination in a different, non-hermaphroditic nematode species. Collectively, our findings identify thermosensitive BiP as a conserved temperature sensor in TGSD, and provide mechanistic insights into the transition between GGSD and TGSD.

2.
Small ; 20(30): e2310847, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38385814

RESUMO

Sensing pressure and temperature are two important functions of human skin that integrate different types of tactile receptors. In this paper, a deformable artificial flexible multi-stimulus-responsive sensor is demonstrated that can distinguish mechanical pressure from temperature by measuring the impedance and the electrical phase at the same frequency without signal interference. The electrical phase, which is used for measuring the temperature, is totally independent of the pressure by controlling the surface micro-shapes and the ion content of the ionic film. By doping the counter-ion exchange reagent into the ionic liquid before pouring, the upper temperature measuring limit increases from 35 to 50 °C, which is higher than the human body temperature and the ambient temperature on Earth. The sensor shows high sensitivity to pressure (up to 0.495 kPa-1) and a wide temperature sensing range (-10 to 50 °C). A multimodal ion-electronic skin (IEM-skin) with an 8 × 8 multi-stimulus-responsive sensor array is fabricated and can successfully sense the distribution of temperature and pressure at the same time. Finally, the sensors are used for monitoring the touching motions of a robot-arm finger controlled by a remote interactive glove and successfully detect the touching states and the temperature changes of different objects.

3.
Small ; 20(32): e2311064, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38396219

RESUMO

Visual sensing of humidity and temperature by solids plays an important role in the everyday life and in industrial processes. Due to their hydrophobic nature, most covalent organic framework (COF) sensors often exhibit poor optical response when exposed to moisture. To overcome this challenge, the optical response is set out to improve, to moisture by incorporating H-bonding ionic functionalities into the COF network. A highly sensitive COF, consisting of guanidinium and diformylpyridine linkers (TG-DFP), capable of detecting changes in temperature and moisture content is fabricated. The hydrophilic nature of the framework enables enhanced water uptake, allowing the trapped water molecules to form a large number of hydrogen bonds. Despite the presence of non-emissive building blocks, the H-bonds restrict internal bond rotation within the COF, leading to reversible fluorescence and solid-state optical hydrochromism in response to relative humidity and temperature.

4.
Small ; : e2404080, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38923218

RESUMO

Functional fibers composed of textiles are considered a promising platform for constructing electronic skin (e-skin). However, developing robust electronic fibers with integrated multiple functions remains a formidable task especially when a complex service environment is concerned. In this work, a continuous and controllable strategy is demonstrated to prepare e-skin-oriented ceramic fibers via coaxial wet spinning followed by cold isostatic pressing. The resulting core-shell structured fiber with tightly compacted Al-doped ZnO nanoparticles in the core and highly ordered aramid nanofibers in the shell exhibit excellent tensile strength (316 MPa) with ultra-high elongation (33%). Benefiting from the susceptible contacts between conducting ceramic nanoparticles, the ceramic fiber shows both ultrahigh sensitivity (gauge factor = 2141) as a strain sensor and a broad working range up to 70 °C as a temperature sensor. Furthermore, the tunable core-shell structure of the fiber enables the optimization of impedance matching and attenuation of electromagnetic waves for the corresponding textile, resulting in a minimum reflection loss of -39.1 dB and an effective absorption bandwidth covering the whole X-band. Therefore, the versatile core-shell ceramic fiber-derived textile can serve as a stealth e-skin for monitoring the motion and temperature of robots under harsh conditions.

5.
J Fluoresc ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38771406

RESUMO

The tip of a piece of plastic fiber was dyed with thymol blue to form a temperature probe. The fiber optic sensor was calibrated on a heatboard by comparison with a K-type thermal couple. Fluorescence characteristics including fluorescence intensity, emission bandwidth, peak & barycenter wavelengths, and self-referenced intensity ratio were used to carry the information of environment temperature. Accordingly, more than five temperature sensing functions were retrieved from the fluorescent sensor. Among such functions, the emission band barycenter showed premium precision. Temperature-driven shift of the emission band barycenter has a sensitivity of 0.095 nm/K, with a nonlinearity of 2.2%FS, resolution of 4 K and repeatability of 1.8%FS. The sensor can find its applications in wearable devices and radiofrequency ablation. Finally in a verification experiment, the sensor was used to monitor the temperature of a microwave oven chamber in real time.

6.
Anim Biotechnol ; 35(1): 2299944, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38164963

RESUMO

Cattle are sensitive to temperature fluctuations but adapt well to inclement weather conditions. When environmental temperatures exceed specific thresholds, heat stress becomes a critical concern for cattle. The TRPM2 gene, which resides on cattle chromosome 1 encodes a TRP channel protein, holding a unique capacity to sense temperature changes and facilitate rapid response to avoid heat stress. Here, we utilized the Bovine Genome Variation Database (BGVD) (http://animal.omics.pro/code/index.php/BosVar), and identified a missense mutation site, c.805A > G: p. Met269Val (rs527146862), within the TRPM2 gene. To elucidate the functional assessment of this mutation in temperature adaptation attributes of Chinese cattle, we genotyped 407 samples from 20 distinct breeds representing diverse climatic zones across China. The association analysis incorporates three temperature parameters and revealed compelling insights in terms of allele frequency. Interestingly, the prevalence of the wild-type allele A was notably higher among northern cattle breeds and this trend diminished gradually as observed in southern cattle populations. Conversely, the mutant-type allele G demonstrated a contrasting trend. Moreover, southern cattle exhibited markedly higher frequencies of GG and GA genotypes (P < 0.01). The presence of heterozygous and homozygous mutations appears to confer an enhanced capacity for adaptation to elevated temperatures. These results provide unequivocal correlation evidence between TRPM2 genotypes (AA, GA, GG) and environmental temperature parameters and comprehend the genetic mechanisms governing temperature adaptation in cattle. This provides valuable insights for strategic breed selection across diverse climatic regions, thereby aiding livestock production amid evolving climate challenges.


The TRPM2 gene encodes TRP channel protein that helps animals in combating heat stress. Twenty Chinese local cattle breeds were genotyped, and association analysis was performed. This investigation encompasses the distribution pattern of the missense mutation locus rs527146862 of the TRPM2 gene in southern, northern, and central cattle populations. The results demonstrated a significant relationship between rs527146862 locus and temperature adaptation attributes in Chinese cattle.


Assuntos
Canais de Cátion TRPM , Bovinos/genética , Animais , Temperatura , Canais de Cátion TRPM/genética , Frequência do Gene , Genótipo , Mutação de Sentido Incorreto , Polimorfismo de Nucleotídeo Único
7.
Sensors (Basel) ; 24(11)2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38894474

RESUMO

A highly sensitivity balloon-like fiber interferometer based on ethanol coating is presented in this paper. The Mach-Zehnder interferometer is formed by bending a single-mode fiber to a balloon-like structure and nested in the Teflon tube. Then, an ethanol solution was filled into the tube of the balloon-like fiber interferometer by the capillary effect. Due to the high sensitivity of the refractive index (RI) of ethanol solutions to temperature, when the external temperature varies, the optical path difference changes. The change in temperature can be detected by the shift in the interference spectrum. Limited by the size of the balloon-like structure, three kinds of these structures with different sensitive lengths were prepared to select the best parameters. The sensitive lengths were 10, 15 and 20 mm, respectively, and the RI detection performance of each structure in 10~26% NaCl solutions was investigated experimentally. The results show that when the sensitive length is 20 mm, the RI sensitivity of the sensor is the highest, which is 212.88 nm/RIU. Ultimately, the sensitive length filled with ethanol is 20 mm. The experimental results show that the temperature sensitivity of the structure is 1.145 nm/°C in the range of 28.1 °C~35 °C, which is 10.3 times higher than that of an unfilled balloon-like structure (0.111 nm/°C). The system has the advantages of low cost and easy fabrication, which can potentially be used in high-precision temperature monitoring processes.

8.
Sensors (Basel) ; 24(15)2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39123929

RESUMO

The transition from wakefulness to sleep occurs when the core body temperature decreases. The latter is facilitated by an increase in the cutaneous blood flow, which dissipates internal heat into the micro-environment surrounding the sleeper's body. The rise in cutaneous blood flow near sleep onset causes the distal (hands and feet) and proximal (abdomen) temperatures to increase by about 1 °C and 0.5 °C, respectively. Characterizing the dynamics of skin temperature changes throughout sleep phases and understanding its relationship with sleep quality requires a means to unobtrusively and longitudinally estimate the skin temperature. Leveraging the data from a temperature sensor strip (TSS) with five individual temperature sensors embedded near the surface of a smart bed's mattress, we have developed an algorithm to estimate the distal skin temperature with a minute-long temporal resolution. The data from 18 participants who recorded TSS and ground-truth temperature data from sleep during 14 nights at home and 2 nights in a lab were used to develop an algorithm that uses a two-stage regression model (gradient boosted tree followed by a random forest) to estimate the distal skin temperature. A five-fold cross-validation procedure was applied to train and validate the model such that the data from a participant could only be either in the training or validation set but not in both. The algorithm verification was performed with the in-lab data. The algorithm presented in this research can estimate the distal skin temperature at a minute-level resolution, with accuracy characterized by the mean limits of agreement [-0.79 to +0.79 °C] and mean coefficient of determination R2=0.87. This method may enable the unobtrusive, longitudinal and ecologically valid collection of distal skin temperature values during sleep. Therelatively small sample size motivates the need for further validation efforts.


Assuntos
Algoritmos , Leitos , Temperatura Cutânea , Sono , Temperatura Cutânea/fisiologia , Humanos , Sono/fisiologia , Masculino , Feminino , Adulto , Vigília/fisiologia , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação
9.
Sensors (Basel) ; 24(10)2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38793882

RESUMO

In this work, we experimentally analyzed and demonstrated the performance of an in-line Mach-Zehnder interferometer in the visible region, with an LED light source. The different waist diameter taper and asymmetric core-offset interferometers proposed used a single-mode fiber (SMF). The visibility achieved was V = 0.14 with an FSR of 23 nm for the taper MZI structure and visibilities of V = 0.3, V = 0.27, and V = 0.34 with FSRs of 23 nm, 17 nm, and 8 nm and separation lengths L of 2.5 cm, 4.0 cm, and 5.0 cm between the core-offset structure, respectively. The experimental investigation of the response to the temperature sensor yielded values from 50 °C to 300 °C; the sensitivity obtained was 3.53 a.u./°C, with R2 of 0.99769 and 1% every 1 °C in the transmission. For a range of 50 °C to 150 °C, 20.3 pm/°C with a R2 of 0.96604 was obtained.

10.
Sensors (Basel) ; 24(4)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38400436

RESUMO

This paper introduces an innovative sensor utilizing bubbles coated with thermochromic paint, aiming to facilitate temperature measurements in challenging-to-reach locations without the requirement of an external power source. The research conducted is innovative in terms of both methodology and application. The characterization of the thermochromic properties of paints was, in fact, performed using spectroradiometric measurements by selecting a temperature range useful for applications in various fields including preventive conservation. The study encompasses two main objectives: (1) analyzing the color characteristics of thermochromic paint and plastic resin that forms the bubbles, and (2) assessing a temperature sensor comprising a thermochromic paint-coated bubble subjected to temperature variations. The thermochromic paint exhibits reversible color modifications in response to temperature changes, making it an ideal candidate for applications of this nature. The color characterization phase involves measurements using a spectroradiometer to compare the spectral reflectance factor (SRF%) of the colored plastic resin spread on canvas with that of the inflated bubbles. The sensor characterization entails evaluating color changes of the thermochromic paint on the bubble surface with varying temperatures. Experimental results indicate that the combination of a red (R) bubble and blue (B) thermochromic paint produces quantifiable color variations suitable for the proposed applications, whereas the alternative combination under examination, namely a blue bubble and red thermochromic paint, yields less accurate results. Considering that for both thermochromic paints the color change temperature is 35 °C, it is possible to see how, for B bubble with R thermochromic paint, the chromatic coordinates change value: C* = 3.14 ± 0.14 and h = 289.54 ± 11.58 at room temperature, while C* = 2.96 ± 0.12 and h = 304.20 ± 12.17 at 35 °C. The same is true for R bubble with B thermochromic paint where C* = 25.31 ± 1.01 and h* = 285.05 ± 11.40 at room temperature, while C* = 20.87 ± 0.85 and h = 288.37 ± 11.53 at 35 °C. The study demonstrates the potential of the approach and suggests further investigations into reproducibility and expanded color combinations. The results provide a promising basis for future improvements in temperature monitoring with thermochromic bubble sensors.

11.
Sensors (Basel) ; 24(2)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38257533

RESUMO

This paper details the development and validation of a temperature sensing methodology using an un-trimmed oscillator-based integrated sensor implemented in the 0.18-µm SOI XFAB process, with a focus on thermal monitoring in system-on-chip (SoC) based DC-DC converters. Our study identifies a quadratic relationship between the oscillator output frequency and temperature, which forms the basis of our proposed calibration mechanism. This mechanism aims at mitigating process variation effects, enabling accurate temperature-to-frequency mapping. Our research proposes and characterizes several trimming-free calibration techniques, covering a spectrum from zero to thirty-one frequency-temperature measurement points. Notably, the Corrected One-Point calibration method, requiring only a single ambient temperature measurement, emerges as a practical solution that removes the need for a temperature chamber. This method, after adjustment, successfully reduces the maximum error to within ±2.95 °C. Additionally, the Two-Point calibration method demonstrates improved precision with a maximum positive error of +1.56 °C at -15 °C and a maximum negative error of -3.13 °C at +10 °C (R2 value of 0.9958). The Three-Point calibration method performed similarly, yielding an R2 value of 0.9956. The findings of this study indicate that competitive results in temperature sensor calibration can be achieved without circuit trimming, offering a viable alternative or a complementary approach to traditional trimming techniques.

12.
Sensors (Basel) ; 24(7)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38610472

RESUMO

The market for smart greenhouses has been valued at USD 1.77 billion in 2022 and is expected to grow to 3.39 billion by 2030. In order to make this more efficient, with the help of Internet of Things (IoT) technology, it is desired to eliminate the problem of traditional agriculture, which has poor monitoring and accuracy control of the parameters of a culture. Climate control decisions in a greenhouse are made based on parameter monitoring systems, which can be remotely controlled. Instead of this adjustment of the measured parameters, it would be preferable from the point of view of energy consumption that they should be calculated at optimal values from the design phase of the greenhouse. For this reason, it would be better to perform an energy simulation of the greenhouse first. For the study carried out in this work, a small greenhouse (mini-greenhouse) was built. It was equipped with an IoT sensor system, which measured indoor climate parameters and could send data to the cloud for future recording and processing. A simplified mathematical model of the heat balance was established, and the measured internal parameters of the mini-greenhouse were compared with those obtained from the simulation. After validating the mathematical model of the mini-greenhouse, this paper aimed to find the optimal position for placing a normal-sized greenhouse. For this, several possible locations and orientations of the greenhouse were compared by running the mathematical model, with which the most unfavorable positions could be eliminated. Then, some considerably cheaper "mini-greenhouses" were made and placed in the locations with the desired orientations. Using sensor systems and technologies similar to those presented in this work, the parameters from all mini-greenhouses can be monitored in real time. This real-time monitoring allows for the simultaneous analysis of all greenhouses, without the disadvantages of data collection directly in the field, with all data being recorded in the cloud and other IoT-specific advantages being made use of. In the end, we can choose the optimal solution for the location of a real-size greenhouse.

13.
Nano Lett ; 23(11): 5391-5398, 2023 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-36971404

RESUMO

Since thermometry of human skin is critical information that provides important aspects of human health and physiology, accurate and continuous temperature measurement is required for the observation of physical abnormalities. However, conventional thermometers are uncomfortable because of their bulky and heavy features. In this work, we fabricated a thin, stretchable array-type temperature sensor using graphene-based materials. Furthermore, we controlled the degree of graphene oxide reduction and enhanced the temperature sensitivity. The sensor exhibited an excellent sensitivity of 2.085% °C-1. The overall device was designed in a wavy meander shape to provide stretchability for the device so that precise detection of skin temperature could be performed. Furthermore, polyimide film was coated to secure the chemical and mechanical stabilities of the device. The array-type sensor enabled spatial heat mapping with high resolution. Finally, we introduced some practical applications of skin temperature sensing, suggesting the possibility of skin thermography and healthcare monitoring.


Assuntos
Grafite , Temperatura Cutânea , Humanos , Temperatura , Termografia
14.
Chemistry ; 29(57): e202301800, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37496278

RESUMO

Solid-state ionic conductive elastomers (ICEs) can fundamentally overcome the disadvantages of hydrogels and ionogels (their liquid components tend to leak or evaporate), and are considered to be ideal materials for flexible ionic sensors. In this study, a liquid-free ionic polyurethane (PU) type conductive elastomer (ICE-2) was synthesized and studied. The PU type matrix with microphase separation endowed ICE-2 with excellent mechanical versatility. The disulfide bond exchange reaction in the hard phase and intermolecular hydrogen bonds contributed to damage repairing ability. ICE-2 exhibited good ionic conductivity (2.86×10-6  S/cm), high transparency (average transmittance >89 %, 400~800 nm), excellent mechanical properties (tensile strength of 3.06 MPa, elongation at break of 1760 %, and fracture energy of 14.98 kJ/m2 ), appreciable self-healing ability (healing efficiency >90 %), satisfactory environmental stability, and outstanding recyclability. The sensor constructed by ICE-2 could not only realize the perception of temperature changes, but also accurately and sensitively detect various human activities, including joint movements and micro-expression changes. This study provides a simple and effective strategy for the development of flexible and soft ionic conductors for sensors and human-machine interfaces.

15.
Nanotechnology ; 35(5)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37879329

RESUMO

Inkjet-printable ink formulated with graphene oxide (GO) offers several advantages, including aqueous dispersion, low cost, and environmentally friendly production. However, water-based GO ink encounters challenges such as high surface tension, low wetting properties, and reduced ink stability over prolonged storage time. Alkali lignin, a natural surfactant, is promising in improving GO ink's stability, wettability, and printing characteristics. The concentration of surfactant additives is a key factor in fine-tuning GO ink's stability and printing properties. The current study aims to explore the detailed effects of alkali lignin concentration and optimize the overall properties of graphene oxide (GO) ink for drop-on-demand thermal inkjet printing. A meander-shaped temperature sensor electrode was printed using the optimized GO ink to demonstrate its practical applicability for commercial purposes. The sensing properties are evaluated using a simple experimental setup across a range of temperatures. The findings demonstrate a significant increase in zeta potential by 25% and maximum absorption by 84.3%, indicating enhanced stability during prolonged storage with an optimized alkali lignin concentration compared to the pure GO dispersions. The temperature sensor exhibits a remarkable thermal coefficient of resistance of 1.21 within the temperature range of 25 °C-52 °C, indicative of excellent sensitivity, response, and recovery time. These results highlight the potential of alkali lignin as a natural surfactant for improving the performance and applicability of inkjet-printable GO inks in various technological applications.

16.
Proc Natl Acad Sci U S A ; 117(33): 20298-20304, 2020 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-32747539

RESUMO

In mammals, temperature-sensitive TRP channels make membrane conductance of cells extremely temperature dependent, allowing the detection of temperature ranging from noxious cold to noxious heat. We progressively deleted the distal carboxyl terminus domain (CTD) of the cold-activated melastatin receptor channel, TRPM8. We found that the enthalpy change associated with channel gating is proportional to the length of the CTD. Deletion of the last 36 amino acids of the CTD transforms TRPM8 into a reduced temperature-sensitivity channel (Q10 ∼4). Exposing the intracellular domain to a denaturing agent increases the energy required to open the channel indicating that cold drives channel gating by stabilizing the folded state of the CTD. Experiments in the presence of an osmoticant agent suggest that channel gating involves a change in solute-inaccessible volume in the CTD of ∼1,900 Å3 This volume matches the void space inside the coiled coil according to the cryogenic electron microscopy structure of TRPM8. The results indicate that a folding-unfolding reaction of a specialized temperature-sensitive structure is coupled to TRPM8 gating.


Assuntos
Domínios Proteicos , Dobramento de Proteína , Canais de Cátion TRPM/química , Animais , Temperatura Baixa , Microscopia Crioeletrônica , Humanos , Ativação do Canal Iônico , Modelos Moleculares , Mutagênese Sítio-Dirigida , Mutação , Oócitos , Conformação Proteica , Canais de Cátion TRPM/metabolismo , Termodinâmica , Xenopus laevis
17.
Sensors (Basel) ; 23(14)2023 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-37514926

RESUMO

The Vernier effect created using an incorporated Lyot-Sagnac loop is used to create an ultra-high sensitivity temperature sensor based on a ring laser cavity. Unlike standard double Sagnac loop systems, the proposed sensor is fused into a single Sagnac loop by adjusting the welding angle between two polarization-maintaining fibers (PMFs) to achieve effective temperature sensitivity amplification. The PMFs are separated into two arms of 0.8 m and 1 m in length, with a 45° angle difference between the fast axes. The sensor's performance is examined both theoretically and experimentally. The experimental results reveal that the Vernier amplification effect can be achieved via PMF rotating shaft welding. The temperature sensitivity in the laser cavity can reach 2.391 nm/°C, which is increased by a factor of more than eight times compared with a single Sagnac loop structure (0.298 nm/°C) with a length of 0.8 m without the Vernier effect at temperatures ranging from 20 °C to 30 °C. Furthermore, unlike traditional optical fiber sensing that uses a broadband light source (BBS) for detection, which causes issues such as low signal-to-noise ratio and broad bandwidth, the Sagnac loop can be employed as a filter by inserting itself into the fiber ring laser (FRL) cavity. When the external parameters change, the laser is offset by the interference general modulation, allowing the external temperature to be monitored. The superior performance of signal-to-noise ratios of up to 50 dB and bandwidths of less than 0.2 nm is achieved. The proposed sensor has a simple structure and high sensitivity and is expected to play a role in biological cell activity monitoring.

18.
Sensors (Basel) ; 23(12)2023 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-37420547

RESUMO

Achieving carbon neutrality is important to solve environmental problems and thus requires decarbonizing manufacturing processes to reduce greenhouse gas emissions. The firing of ceramics, including calcination and sintering, is a typical fossil fuels-driven manufacturing process that requires large power consumption. Although the firing process in manufacturing ceramics cannot be eliminated, an effective firing strategy to reduce processing steps can be a choice to lower power consumption. Herein, we suggest a one-step solid solution reaction (SSR) route to manufacture (Ni, Co, and Mn)O4 (NMC) electroceramics for their application in temperature sensors with negative temperature coefficient (NTC). Additionally, the effect of the one-step SSR route on the electrical properties of the NMC is investigated. Similar to the NMC prepared using the two-step SSR route, spinel structures with dense microstructure are observed in the NMC prepared via the one-step SSR route. Based on the experimental results, the one-step SSR route can be considered as one of the effective processing techniques with less power consumption to manufacture electroceramics.


Assuntos
Óxido de Alumínio , Óxido de Magnésio , Temperatura
19.
Sensors (Basel) ; 23(1)2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36617081

RESUMO

In this paper, a ratiometric approach to sensing temperature variations is shown using specialty fiber optic devices. We analyzed the transmission response of cascaded segments of multicore fibers (MCFs), and dissimilar lengths were found to generate an adequate scheme for ratiometric operation. The perturbation of optical parameters in the MCFs translates to a rich spectral behavior in which some peaks increase their intensity while others decrease their intensity. Thus, by selecting opposite-behavior peaks, highly sensitive ratiometric measurements that provide robustness against spurious fluctuations can be performed. We implemented this approach using seven-core fiber (SCF) segments of 5.8 cm and 9.9 cm. To test the system's response under controlled perturbations, we heated one of the segments from ambient temperature up to 150 °C. We observed defined peaks with opposite behavior as a function of temperature. Two pairs of peaks within the interrogation window were selected to perform ratiometric calculations. Ratiometric measurements exhibited sensitivities 6-14 times higher than single-wavelength measurements. A similar trend with enhanced sensitivity in both peak pairs was obtained. In contrast to conventional interferometric schemes, the proposed approach does not require expensive facilities or micrometric-resolution equipment. Moreover, our approach has the potential to be realized using commercial splicers, detectors, and filters.

20.
Sensors (Basel) ; 23(5)2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36904819

RESUMO

This paper introduces a digital interface application-specific integrated circuit (ASIC) for a micro-electromechanical systems (MEMS) vibratory gyroscope. The driving circuit of the interface ASIC uses an automatic gain circuit (AGC) module instead of a phase-locked loop to realize a self-excited vibration, which gives the gyroscope system good robustness. In order to realize the co-simulation of the mechanically sensitive structure and interface circuit of the gyroscope, the equivalent electrical model analysis and modeling of the mechanically sensitive structure of the gyro are carried out by Verilog-A. According to the design scheme of the MEMS gyroscope interface circuit, a system-level simulation model including mechanically sensitive structure and measurement and control circuit is established by SIMULINK. A digital-to-analog converter (ADC) is designed for the digital processing and temperature compensation of the angular velocity in the MEMS gyroscope digital circuit system. Using the positive and negative diode temperature characteristics, the function of the on-chip temperature sensor is realized, and the temperature compensation and zero bias correction are carried out simultaneously. The MEMS interface ASIC is designed using a standard 0.18 µM CMOS BCD process. The experimental results show that the signal-to-noise ratio (SNR) of sigma-delta (ΣΔ) ADC is 111.56 dB. The nonlinearity of the MEMS gyroscope system is 0.03% over the full-scale range.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa