Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 853
Filtrar
Mais filtros

Eixos temáticos
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 119(29): e2203199119, 2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35858350

RESUMO

Lithium-ion battery (LIB) is a broadly adopted technology for energy storage. With increasing demands to improve the rate capability, cyclability, energy density, safety, and cost efficiency, it is crucial to establish an in-depth understanding of the detailed structural evolution and cell-degradation mechanisms during battery operation. Here, we present a laboratory-based high-resolution and high-throughput X-ray micro-computed laminography approach, which is capable of in situ visualizing of an industry-relevant lithium-ion (Li-ion) pouch cell with superior detection fidelity, resolution, and reliability. This technique enables imaging of the pouch cell at a spatial resolution of 0.5 µm in a laboratory system and permits the identification of submicron features within cathode and anode electrodes. We also demonstrate direct visualization of the lithium plating in the imaged pouch cell, which is an important phenomenon relevant to battery fast charging and low-temperature cycling. Our development presents an avenue toward a thorough understanding of the correlation among multiscale structures, chemomechanical degradation, and electrochemical behavior of industry-scale battery pouch cells.

2.
BMC Cancer ; 24(1): 121, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267903

RESUMO

BACKGROUND: Programmed death-1 (PD-1) and programmed death-ligand 1 (PD-L1) are the two most common immune checkpoints targeted in triple-negative breast cancer (BC). Refining patient selection for immunotherapy is non-trivial and finding an appropriate digital pathology framework for spatial analysis of theranostic biomarkers for PD-1/PD-L1 inhibitors remains an unmet clinical need. METHODS: We describe a novel computer-assisted tool for three-dimensional (3D) imaging of PD-L1 expression in immunofluorescence-stained and optically cleared BC specimens (n = 20). The proposed 3D framework appeared to be feasible and showed a high overall agreement with traditional, clinical-grade two-dimensional (2D) staining techniques. Additionally, the results obtained for automated immune cell detection and analysis of PD-L1 expression were satisfactory. RESULTS: The spatial distribution of PD-L1 expression was heterogeneous across various BC tissue layers in the 3D space. Notably, there were six cases (30%) wherein PD-L1 expression levels along different layers crossed the 1% threshold for admitting patients to PD-1/PD-L1 inhibitors. The average PD-L1 expression in 3D space was different from that of traditional immunohistochemistry (IHC) in eight cases (40%). Pending further standardization and optimization, we expect that our technology will become a valuable addition for assessing PD-L1 expression in patients with BC. CONCLUSION: Via a single round of immunofluorescence imaging, our approach may provide a considerable improvement in patient stratification for cancer immunotherapy as compared with standard techniques.


Assuntos
Antígeno B7-H1 , Neoplasias da Mama , Humanos , Feminino , Imageamento Tridimensional , Inibidores de Checkpoint Imunológico , Ligantes , Receptor de Morte Celular Programada 1 , Corantes , Computadores
3.
Eur Radiol ; 34(4): 2689-2698, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37804340

RESUMO

OBJECTIVES: Visualizing left atrial anatomy including the pulmonary veins (PVs) is important for planning the procedure of pulmonary vein isolation with ablation in patients with atrial fibrillation (AF). The aims of our study are to investigate the feasibility of the 3D whole-heart bright-blood and black-blood phase-sensitive (BOOST) inversion recovery sequence in patients with AF scheduled for ablation or electro-cardioversion, and to analyze the correlation between image quality and heart rate and rhythm of patients. METHODS: BOOST was performed for assessing PVs both with T2 preparation pre-pulse (T2prep) and magnetization transfer preparation (MTC) in 45 patients with paroxysmal or permanent AF scheduled for ablation or electro-cardioversion. Image quality analyses were performed by two independent observers. Qualitative assessment was made using the Likert scale; for quantitative analysis, signal to noise ratios (SNR) and contrast to noise ratios (CNR) were calculated for each PV. Heart rate and rhythm were analyzed based on standard 12-lead ECGs. RESULTS: All MTC-BOOST acquisitions achieved diagnostic quality in the PVs, while a significant proportion of T2prep-BOOST images were not suitable for assessing PVs. SNR and CNR values of the MTC-BOOST bright-blood images were higher if patients had sinus rhythm. We found a significant or nearly significant negative correlation between heart rate and the SNR and CNR values of MTC-BOOST bright-blood images. CONCLUSION: 3D whole-heart MTC-BOOST bright-blood imaging is suitable for visualizing the PVs in patients with AF, producing diagnostic image quality in 100% of cases. However, image quality was influenced by heart rate and rhythm. CLINICAL RELEVANCE STATEMENT: The novel 3D whole-heart BOOST CMR sequence needs no contrast administration and is performed during free-breathing; therefore, it is easy to use for a wide range of patients and is suitable for visualizing the PVs in patients with AF. KEY POINTS: • The applicability of the novel 3D whole-heart bright-blood and black-blood phase-sensitive sequence to pulmonary vein imaging in clinical practice is unknown. • Magnetization transfer-bright-blood and black-blood phase-sensitive imaging is suitable for visualizing the pulmonary veins in patients with atrial fibrillation with excellent or good image quality. • Bright-blood and black-blood phase-sensitive cardiac magnetic resonance sequence is easy to use for a wide range of patients as it needs no contrast administration and is performed during free-breathing.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Viabilidade , Átrios do Coração/diagnóstico por imagem , Eletrocardiografia , Imageamento por Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
4.
Int J Legal Med ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38856752

RESUMO

Investigation of the biological sex of human remains is a crucial aspect of physical anthropology. However, due to varying states of skeletal preservation, multiple approaches and structures of interest need to be explored. This research aims to investigate the potential use of distances between bifrontal breadth (FMB), infraorbital foramina distance (IOD), nasal breadth (NLB), inter-canine width (ICD), and distance between mental foramina (MFD) for combined sex prediction through traditional statistical methods and through open-access machine-learning tools. Ethical approval was obtained from the ethics committee, and out of 100 cone beam computed tomography (CBCT) scans, 54 individuals were selected with all the points visible. Ten extra exams were chosen to test the predictors developed from the learning sample. Descriptive analysis of measurements, standard deviation, and standard error were obtained. T-student and Mann-Whitney tests were utilized to assess the sex differences within the variables. A logistic regression equation was developed and tested for the investigation of the biological sex as well as decision trees, random forest, and artificial neural networks machine-learning models. The results indicate a strong correlation between the measurements and the sex of individuals. When combined, the measurements were able to predict sex using a regression formula or machine learning based models which can be exported and added to software or webpages. Considering the methods, the estimations showed an accuracy rate superior to 80% for males and 82% for females. All skulls in the test sample were accurately predicted by both statistical and machine-learning models. This exploratory study successfully established a correlation between facial measurements and the sex of individuals, validating the prediction potential of machine learning, augmenting the investigative tools available to experts with a high differentiation potential.

5.
J Clin Periodontol ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710641

RESUMO

AIM: This retrospective cohort study aimed to volumetrically investigate the bone stability rate of prefabricated allogeneic bone blocks (PBB) and computer-aided design (CAD)/computer-aided manufacturing (CAM) custom-milled allogeneic bone blocks (CCBB) for ridge augmentation. MATERIALS AND METHODS: Nineteen patients were treated with 20 allografts: 11 CCBB, 9 PBB; 10 in the maxilla and 10 in the mandible. Clinical treatment history and cone beam computed tomography scans before surgery (t0), directly after graft surgery (t1) and after 6 months of healing prior to implant insertion (t2) were evaluated using a three-dimensional evaluation software for absolute bone volume, stability as well as vertical and horizontal bone gain. Furthermore, the inserted implants were analysed for survival, marginal bone loss (MBL) and complications for a mean follow-up period of 43.75 (±33.94) months. RESULTS: A mean absolute volume of 2228.1 mm3 (±1205) was grafted at t1. The bone stability rate was 87.6% (±9.9) for CCBB and 83.0% (±14.5) for PBB. The stability was higher in the maxilla (91.6%) than in the mandible (79.53%). Surgery time of PBB was longer than for CCBB (mean Δ = 52 min). The survival rate of the inserted implants was 100% with a mean MBL of 0.41 mm (±0.37). CONCLUSION: The clinical performance of both allograft block designs was equally satisfactory for vertical and horizontal bone grafting prior to implant placement. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov: NCT06027710.

6.
MAGMA ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758490

RESUMO

OBJECT: In a typical MR session, several contrasts are acquired. Due to the sequential nature of the data acquisition process, the patient may experience some discomfort at some point during the session, and start moving. Hence, it is quite common to have MR sessions where some contrasts are well-resolved, while other contrasts exhibit motion artifacts. Instead of repeating the scans that are corrupted by motion, we introduce a reference-guided retrospective motion correction scheme that takes advantage of the motion-free scans, based on a generalized rigid registration routine. MATERIALS AND METHODS: We focus on various existing clinical 3D brain protocols at 1.5 Tesla MRI based on Cartesian sampling. Controlled experiments with three healthy volunteers and three levels of motion are performed. RESULTS: Radiological inspection confirms that the proposed method consistently ameliorates the corrupted scans. Furthermore, for the set of specific motion tests performed in this study, the quality indexes based on PSNR and SSIM shows only a modest decrease in correction quality as a function of motion complexity. DISCUSSION: While the results on controlled experiments are positive, future applications to patient data will ultimately clarify whether the proposed correction scheme satisfies the radiological requirements.

7.
Eur Spine J ; 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38683383

RESUMO

PURPOSE: To provide lumbar spine anatomical parameters relevant to the UBE technique and explore their intraoperative application. METHODS: CT imaging data processed by Mimics for parametric measurements, including laminar abduction angle (LAA), laminar slope angle (LSA), minimum laminar height (MLH), distance between the inferior margin of the lamina and attachment of the ligamentum flavum onto the cephalad lamina (DLL), distance between the initial point and the middle of the articular process (DIA), and distance from the inferior margin of the lamina to the inferior border of the vertebral body (DLV), and were manually measured. RESULTS: LAA and DIA gradually increase from L1 to L5. At L1, the DIA is approximately the length of 2 drill bits with a diameter of 3 mm (male: 7.77 ± 1.39 mm, female: 7.22 ± 1.09 mm), while at L5, it can reach the length of 4-5 drill bits (male: 14.96 ± 2.24 mm, female: 13.67 ± 2.33 mm). MLH, DLL, and DLV reach their maximum values at the L3 and decrease toward the cranial and caudal ends. The DLL is smallest at L5 (male: 9.58 ± 1.90 mm, female: 9.38 ± 2.14 mm), equivalent to the length of 3 drill bits, while the DLL at L3 is the length of 4-5 drill bits (male: 14.17 ± 2.13 mm, female: 14.01 ± 2.07 mm). CONCLUSION: Referring to the drill diameter during surgery can mark the extent of laminotomy. The characteristics of vertebral plate angles at different lumbar levels can provide references for preoperative incision design.

8.
Eur Spine J ; 33(5): 2031-2042, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38548932

RESUMO

PURPOSE: To assess whether the intention to intraoperatively reposition pedicle screws differs when spine surgeons evaluate the same screws with 2D imaging or 3D imaging. METHODS: In this online survey study, 21 spine surgeons evaluated eight pedicle screws from patients who had undergone posterior spinal fixation. In a simulated intraoperative setting, surgeons had to decide if they would reposition a marked pedicle screw based on its position in the provided radiologic imaging. The eight assessed pedicle screws varied in radiologic position, including two screws positioned within the pedicle, two breaching the pedicle cortex < 2 mm, two breaching the pedicle cortex 2-4 mm, and two positioned completely outside the pedicle. Surgeons assessed each pedicle screw twice without knowing and in random order: once with a scrollable three-dimensional (3D) image and once with two oblique fluoroscopic two-dimensional (2D) images. RESULTS: Almost all surgeons (19/21) intended to reposition more pedicle screws based on 3D imaging than on 2D imaging, with a mean number of pedicle screws to be repositioned of, respectively, 4.1 (± 1.3) and 2.0 (± 1.3; p < 0.001). Surgeons intended to reposition two screws placed completely outside the pedicle, one breaching 2-4mm, and one breaching < 2 mm more often based on 3D imaging. CONCLUSION: When provided with 3D imaging, spine surgeons not only intend to intraoperatively reposition pedicle screws at risk of causing postoperative complications more often but also screws with acceptable positions. This study highlights the potential of intraoperative 3D imaging as well as the need for consensus on how to act on intraoperative 3D information.


Assuntos
Parafusos Pediculares , Humanos , Fusão Vertebral/métodos , Coluna Vertebral/cirurgia , Coluna Vertebral/diagnóstico por imagem , Tomada de Decisão Clínica/métodos , Imageamento Tridimensional/métodos , Inquéritos e Questionários , Cirurgiões
9.
Proc Natl Acad Sci U S A ; 118(31)2021 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-34312231

RESUMO

Polyhydroxyalkanoates (PHAs) are biodegradable polyesters that are intracellularly accumulated as distinct insoluble granules by various microorganisms. PHAs have attracted much attention as sustainable substitutes for petroleum-based plastics. However, the formation of PHA granules and their characteristics, such as localization, volume, weight, and density of granules, in an individual live bacterial cell are not well understood. Here, we report the results of three-dimensional (3D) quantitative label-free analysis of PHA granules in individual live bacterial cells through measuring the refractive index distributions by optical diffraction tomography (ODT). The formation and growth of PHA granules in the cells of Cupriavidus necator, the best-studied native PHA producer, and recombinant Escherichia coli harboring C. necator poly(3-hydroxybutyrate) (PHB) biosynthesis pathway are comparatively examined. Through the statistical ODT analyses of the bacterial cells, the distinctive characteristics for density and localization of PHB granules in vivo could be observed. The PHB granules in recombinant E. coli show higher density and localization polarity compared with those of C. necator, indicating that polymer chains are more densely packed and granules tend to be located at the cell poles, respectively. The cells were investigated in more detail through real-time 3D analyses, showing how differently PHA granules are processed in relation to the cell division process in native and nonnative PHA-producing strains. We also show that PHA granule-associated protein PhaM of C. necator plays a key role in making these differences between C. necator and recombinant E. coli strains. This study provides spatiotemporal insights into PHA accumulation inside the native and recombinant bacterial cells.


Assuntos
Cupriavidus necator/química , Escherichia coli/química , Poli-Hidroxialcanoatos/química , Tomografia Óptica/métodos , Cupriavidus necator/metabolismo , Imageamento Tridimensional
10.
Pediatr Radiol ; 54(3): 438-449, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38324089

RESUMO

Virtual surgical planning and three-dimensional (D) printing are rapidly becoming essential for challenging and complex surgeries around the world. An Ibero-American survey reported a lack of awareness of technology benefits and scarce financial resources as the two main barriers to widespread adoption of 3-D technologies. The Pereira Rossell Hospital Center is a publicly funded maternal and pediatric academic clinical center in Uruguay, a low-resource Latin American country, that successfully created and has been running a 3-D unit for 4 years. The present work is a step-by-step review of the 3-D technology implementation process in a hospital with minimal financial investment. References to training, software, hardware, and the management of human resources are included. Difficulties throughout the process and future challenges are also discussed.


Assuntos
Impressão Tridimensional , Cirurgia Assistida por Computador , Humanos , Criança , Uruguai , Cirurgia Assistida por Computador/métodos , Software , Inquéritos e Questionários
11.
Skeletal Radiol ; 53(4): 779-789, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37914895

RESUMO

OBJECTIVE: To evaluate whether 'fast,' unilateral, brachial plexus, 3D magnetic resonance neurography (MRN) acquisitions with deep learning reconstruction (DLR) provide similar image quality to longer, 'standard' scans without DLR. MATERIALS AND METHODS: An IRB-approved prospective cohort of 30 subjects (13F; mean age = 50.3 ± 17.8y) underwent clinical brachial plexus 3.0 T MRN with 3D oblique-coronal STIR-T2-weighted-FSE. 'Standard' and 'fast' scans (time reduction = 23-48%, mean = 33%) were reconstructed without and with DLR. Evaluation of signal-to-noise ratio (SNR) and edge sharpness was performed for 4 image stacks: 'standard non-DLR,' 'standard DLR,' 'fast non-DLR,' and 'fast DLR.' Three raters qualitatively evaluated 'standard non-DLR' and 'fast DLR' for i) bulk motion (4-point scale), ii) nerve conspicuity of proximal and distal suprascapular and axillary nerves (5-point scale), and iii) nerve signal intensity, size, architecture, and presence of a mass (binary). ANOVA or Wilcoxon signed rank test compared differences. Gwet's agreement coefficient (AC2) assessed inter-rater agreement. RESULTS: Quantitative SNR and edge sharpness were superior for DLR versus non-DLR (SNR by + 4.57 to + 6.56 [p < 0.001] for 'standard' and + 4.26 to + 4.37 [p < 0.001] for 'fast;' sharpness by + 0.23 to + 0.52/pixel for 'standard' [p < 0.018] and + 0.21 to + 0.25/pixel for 'fast' [p < 0.003]) and similar between 'standard non-DLR' and 'fast DLR' (SNR: p = 0.436-1, sharpness: p = 0.067-1). Qualitatively, 'standard non-DLR' and 'fast DLR' had similar motion artifact, as well as nerve conspicuity, signal intensity, size and morphology, with high inter-rater agreement (AC2: 'standard' = 0.70-0.98, 'fast DLR' = 0.69-0.97). CONCLUSION: DLR applied to faster, 3D MRN acquisitions provides similar image quality to standard scans. A faster, DL-enabled protocol may replace currently optimized non-DL protocols.


Assuntos
Plexo Braquial , Aprendizado Profundo , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Aumento da Imagem/métodos , Plexo Braquial/anatomia & histologia , Plexo Braquial/patologia
12.
Sensors (Basel) ; 24(10)2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38794100

RESUMO

The field of computer vision has been focusing on achieving accurate three-dimensional (3D) object representations from a single two-dimensional (2D) image through deep artificial neural networks. Recent advancements in 3D shape reconstruction techniques that combine structured light and deep learning show promise in acquiring high-quality geometric information about object surfaces. This paper introduces a new single-shot 3D shape reconstruction method that uses a nonlinear fringe transformation approach through both supervised and unsupervised learning networks. In this method, a deep learning network learns to convert a grayscale fringe input into multiple phase-shifted fringe outputs with different frequencies, which act as an intermediate result for the subsequent 3D reconstruction process using the structured-light fringe projection profilometry technique. Experiments have been conducted to validate the practicality and robustness of the proposed technique. The experimental results demonstrate that the unsupervised learning approach using a deep convolutional generative adversarial network (DCGAN) is superior to the supervised learning approach using UNet in image-to-image generation. The proposed technique's ability to accurately reconstruct 3D shapes of objects using only a single fringe image opens up vast opportunities for its application across diverse real-world scenarios.

13.
Sensors (Basel) ; 24(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38339533

RESUMO

The two-dimensional (2D) cross-hole seismic computed tomography (CT) imaging acquisition method has the potential to characterize the target zone optimally compared to surface seismic surveys. It has wide applications in oil and gas exploration, engineering geology, etc. Limited to 2D hole velocity profiling, this method cannot acquire three-dimensional (3D) information on lateral geological structures outside the profile. Additionally, the sensor data received by cross-hole seismic exploration constitute responses from geological bodies in 3D space and are potentially affected by objects outside the well profiles, distorting the imaging results and geological interpretation. This paper proposes a 3D cross-hole acoustic wave reverse-time migration imaging method to capture 3D cross-hole geological structures using sensor settings in multi-cross-hole seismic research. Based on the analysis of resulting 3D cross-hole images under varying sensor settings, optimizing the observation system can aid in the cost-efficient obtainment of the 3D underground structure distribution. To verify this method's effectiveness on 3D cross-hole structure imaging, numerical simulations were conducted on four typical geological models regarding layers, local high-velocity zones, large dip angles, and faults. The results verify the model's superiority in providing more reliable and accurate 3D geological information for cross-hole seismic exploration, presenting a theoretical basis for processing and interpreting cross-hole data.

14.
Sensors (Basel) ; 24(6)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38543994

RESUMO

In this paper, we propose a method for the three-dimensional (3D) image visualization of objects under photon-starved conditions using multiple observations and statistical estimation. To visualize 3D objects under these conditions, photon counting integral imaging was used, which can extract photons from 3D objects using the Poisson random process. However, this process may not reconstruct 3D images under severely photon-starved conditions due to a lack of photons. Therefore, to solve this problem, in this paper, we propose N-observation photon-counting integral imaging with statistical estimation. Since photons are extracted randomly using the Poisson distribution, increasing the samples of photons can improve the accuracy of photon extraction. In addition, by using a statistical estimation method, such as maximum likelihood estimation, 3D images can be reconstructed. To prove our proposed method, we implemented the optical experiment and calculated its performance metrics, which included the peak signal-to-noise ratio (PSNR), structural similarity (SSIM), peak-to-correlation energy (PCE), and the peak sidelobe ratio (PSR).

15.
Clin Anat ; 37(2): 218-226, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38186377

RESUMO

Symmetry is an essential component of esthetic assessment. Accurate assessment of facial symmetry is critical to the treatment plan of orthognathic surgery and orthodontic treatment. However, there is no internationally accepted midsagittal plane (MSP) for orthodontists and orthognathic surgeons. The purpose of this study was to explore a clinically friendly MSP, which is more accurate and reliable than what is commonly used in symmetry assessment. Forty patients with symmetric craniofacial structures were analyzed on cone-beam computed tomography (CBCT) scans. The CBCT data were exported to the Simplant Pro software to build four reference planes that were constructed by nasion (N), basion (Ba), sella (S), odontoid (Dent), or incisive foramen (IF). A total of 31 landmarks were located to determine which reference plane is the most optimal MSP by comparing the asymmetry index (AI). The mean value of AI showed a significant difference (p < 0.05) among four reference planes. Also, the mean value of AI for all landmarks showed that Plane 2 (consisting of N, Ba, and IF) and Plane 4 (consisting of N, IF, and Dent) were more accurate and stable. In conclusion, the MSP consisting of N, Dent, and IF shows more accuracy and reliability than the other planes. Further, it is more clinically friendly because of its significant advantage in landmarking.


Assuntos
Pontos de Referência Anatômicos , Tomografia Computadorizada de Feixe Cônico , Humanos , Reprodutibilidade dos Testes , Pontos de Referência Anatômicos/diagnóstico por imagem , Cefalometria/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Ossos Faciais , Imageamento Tridimensional/métodos
16.
Nano Lett ; 23(10): 4311-4317, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37155371

RESUMO

Microsphere-assisted super-resolution imaging technology offers label-free, real-time dynamic imaging via white light, which has potential applications in living systems and the nanoscale detection of semiconductor chips. Scanning can aid in overcoming the limitations of the imaging area of a single microsphere superlens. However, the current scanning imaging method based on the microsphere superlens cannot achieve super-resolution optical imaging of complex curved surfaces. Unfortunately, most natural surfaces are composed of complex curved surfaces at the microscale. In this study, we developed a method to overcome this limitation through a microsphere superlens with a feedback capability. By maintaining a constant force between the microspheres and the sample, noninvasive super-resolution optical imaging of complex abiotic and biological surfaces was achieved, and the three-dimensional information on the sample was simultaneously obtained. The proposed method significantly expands the universality of scanning microsphere superlenses for samples and promotes their widespread use.

17.
Aesthetic Plast Surg ; 48(8): 1537-1546, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38334788

RESUMO

BACKGROUND: We hypothesized that application of acellular dermal matrix (ADM) over the orbital septum overlying the herniated orbital fat to tighten and strengthen the attenuated orbital septum in lower blepharoplasty would allow successful repositioning of the herniated orbital fat within the bony orbit. METHODS: The author prospectively compared the cosmetic outcomes of lower blepharoplasty using ADM with standard blepharoplasty. We evaluated recurrence of eyelid bulging and tear trough deformity, volume of the lower periorbital region, and enophthalmos and eyelid droop 1 year after surgery. RESULTS: Twenty-two of the 24 enrolled patients completed the study. There was no significant difference in recurrence of eyelid bulging and tear trough deformity between standard blepharoplasty and blepharoplasty with ADM graft groups. In the standard blepharoplasty group, the volume of the lower periorbital region decreased significantly after surgery. In the blepharoplasty with ADM graft group, there was no significant change in the volume of the lower periorbital region after surgery. In the standard blepharoplasty group, there was no significant change in eyelid droop on either side after surgery. In the blepharoplasty with ADM graft group, the eyelid droop decreased significantly after surgery on the right side but showed no significant change on the left side. There was no significant change in enophthalmos after surgery for either group. CONCLUSIONS: This study demonstrated that ADM graft provided effective support for maintaining the replaced orbital fat in lower blepharoplasty. In the long-term, blepharoplasty with ADM graft might be effective in slowing development of age-related enophthalmos. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Derme Acelular , Tecido Adiposo , Blefaroplastia , Órbita , Humanos , Blefaroplastia/métodos , Feminino , Pessoa de Meia-Idade , Tecido Adiposo/transplante , Masculino , Estudos Prospectivos , Órbita/cirurgia , Adulto , Idoso , Resultado do Tratamento
18.
J Oral Rehabil ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38873694

RESUMO

OBJECTIVE: The aim of this study was to present optimized device-specific low-dose cone-beam computed tomography (CBCT) protocols with sufficient image quality for pre-surgical diagnostics and three-dimensional (3D) modelling of cleft defects. METHODS: Six paediatric skulls were acquired, and an artificial bony cleft was created. A high-resolution CBCT scan acted as a reference standard (Accuitomo 170, Morita, Kyoto, Japan) for comparing eight low-dose protocols of Newtom VGi-evo (QR Verona, Cefla, Verona, Italy), which included Eco and Regular protocols with different field of views (FOVs). Delineation of lamina dura, cementoenamel junction (CEJ), trabecular bone and bony bridge were assessed. A 3D model of the defect was also evaluated. RESULT: The dose area product of low-dose protocols ranged from 31 to 254 mGy*cm2. Despite the dose difference of up to eight times between applied protocols, trabecular bone and CEJ exhibited appropriate image quality in all scans. However, Regular small FOV protocols (5 × 5 and 8 × 5 cm2), for both lamina dura and bony bridge, demonstrated a significant improvement in image quality compared to Eco FOV counterparts. Based on 3D defect analysis, no significant difference existed between low-dose protocols and the reference standard. CONCLUSION: The findings highlight the possibility of achieving a considerable reduction (up to eight times) in the radiation dose using low-dose CBCT protocols while maintaining sufficient image quality for assessing anatomical structures and 3D modelling in cleft cases.

19.
Surg Radiol Anat ; 46(5): 551-558, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38321355

RESUMO

PURPOSE: To measure the volume of the sphenoid and ethmoid sinuses and to analyse the asymmetry index values by age/gender. METHODS: Three-dimensional (3D) Computed Tomography (CT) images of 150 individuals (75 females, 75 males) of both sexes between the ages of 18-75 were included in our study. Sphenoid and ethmoid sinus volumes were measured using the 3D Slicer software package on these images, and the asymmetry index was calculated. RESULTS: In our study, mean sphenoid sinus volume (female right: 4264.4 mm3, left: 3787.1 mm3; male right: 5201.1 mm3, left: 4818.2 mm3) and ethmoid sinus volume (female right: 3365.1 mm3, left: 3321.2 mm3; male right: 3440.9 mm3, left: 3459.5 mm3) were measured in males and females. Left sphenoid sinus values of males were statistically higher than females (p = 0.036). No statistically significant relationship existed between age, sinus volumes, and asymmetry index (p > 0.05). A statistically weak positive correlation existed between males' left sphenoid and ethmoid sinus volume (rho = 0.288; p = 0.012). There was no statistical relationship between asymmetry index in the whole group (p > 0.05). A statistically weak negative correlation was found between sphenoid and ethmoid sinus asymmetry index in males (rho=-0.352; p = 0.002). There was no statistical relationship between asymmetry index in females (p > 0.05). CONCLUSION: Knowing paranasal sinus morphology, morphometry, and asymmetry index value will be significant for preoperative and postoperative periods.


Assuntos
Seio Etmoidal , Imageamento Tridimensional , Seio Esfenoidal , Tomografia Computadorizada por Raios X , Humanos , Seio Esfenoidal/diagnóstico por imagem , Seio Esfenoidal/anatomia & histologia , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Seio Etmoidal/diagnóstico por imagem , Seio Etmoidal/anatomia & histologia , Adolescente , Idoso , Adulto Jovem , Fatores Sexuais , Tamanho do Órgão
20.
Beijing Da Xue Xue Bao Yi Xue Ban ; 56(1): 131-137, 2024 Feb 18.
Artigo em Chinês | MEDLINE | ID: mdl-38318907

RESUMO

OBJECTIVE: To analyze the three-dimensional radiographic characteristics of calcifying odontogenic cyst and calcifying epithelial odontogenic tumor using spiral computed tomography (CT) and cone-beam computed tomography (CBCT). METHODS: Clinical records, histopathological reports, and CBCT or non-enhanced spiral CT images of 19 consecutive patients with calcifying odontogenic cyst (COC) and 16 consecutive patients with calcifying epithelial odontogenic tumor (CEOT) were retrospectively acquired, and radiographic features, including location, size, expansion, internal structure and calcification, were analyzed. RESULTS: Among the 19 COC cases (12 males and 7 females, with an average age of 27 years), 89.5% (17/19) of the lesions originated from the anterior and premolar areas, 100.0% of them exhibited cortex expansion, and 78.9% had discontinued cortex. Among the 16 CEOT cases (3 males and 13 females, with an average age of 36 years), 81.3% (13/16) of the lesions were in the premolar and molar areas, 56.3% of them exhibited cortex expansion, and 96.8% had discontinued cortex. According to the distribution of internal calcifications, these lesions were divided into: Ⅰ (non-calcification type): absence of calcification; Ⅱ (eccentric marginal type): multiple calcifications scattered along one side of the lesion; Ⅲ (diffused type): numerous calcifications diffusely distributed into the lesion; Ⅳ (plaque type): with a ≥ 5 mm calcified patch; Ⅴ (peri-coronal type): multiple calcifications clustered around impacted teeth. Calcifications were present in 73.7% of COC lesions, including 9 type Ⅱ, 3 type Ⅲ and 2 type Ⅳ lesions, and 42.8% of CEOT lesions had calcification images, including 2 type Ⅲ and 5 type Ⅴ lesions. Six COC lesions had odontoma-like images. Moreover, 8 of 9 type Ⅰ CEOTs were histologically Langerhans cell-rich subtype, which had a smaller size (with an average mesiodistal diameter of 17.8 mm) and were not associated with impacted teeth. CONCLUSION: COC lesions tended to originate from the anterior part of the jaw and exhibit cortex expansion, and were sometimes associated with odontoma. CEOT commonly occurred in the posterior jaw and had discontinued cortex. Two lesions had significantly different calcification map. Over 70% of COC lesions had calcification images, which were mostly scattered along one side of the cysts, far from the impacted teeth. Approximately 60% of CEOT lesions exhibited smaller size and non-calcification, and the remaining CEOT cases often had calcification images clustered around the impacted teeth.


Assuntos
Calcinose , Cisto Odontogênico Calcificante , Cistos Odontogênicos , Tumores Odontogênicos , Odontoma , Neoplasias Cutâneas , Dente Impactado , Masculino , Feminino , Humanos , Adulto , Cisto Odontogênico Calcificante/diagnóstico por imagem , Cisto Odontogênico Calcificante/patologia , Odontoma/patologia , Estudos Retrospectivos , Tumores Odontogênicos/diagnóstico por imagem , Cistos Odontogênicos/patologia , Calcinose/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa