Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Am J Obstet Gynecol ; 230(1): 89.e1-89.e12, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37481152

RESUMO

BACKGROUND: Asymptomatic isthmic contractions are a frequent physiological phenomenon in pregnancy, sometimes triggered by bladder voiding. They can interfere with proper cervical length assessment and may lead to false images of placenta previa. However, there is limited research on the prevalence and characteristics of these contractions. OBJECTIVE: This study aimed to determine the prevalence and characteristics of isthmic contractions after bladder voiding in the second trimester of pregnancy, to evaluate their effect on cervical length assessment, and to propose a new method for the objective assessment of the presence and intensity of isthmic contractions. STUDY DESIGN: In this prospective observational study, long videos of the uterine cervix were recorded in 30 singleton pregnancies during the second trimester of pregnancy after bladder voiding. Isthmic length and cervicoisthmic length changes were assessed over time. The isthmic length was measured using a new approach, which involved calculating the distance from the base of the cervix to the internal os, including the isthmus. RESULTS: Isthmic contractions were observed in 43% of pregnant women (95% confidence interval, 26%-62%) after bladder voiding. The median time for complete isthmus relaxation was 19.7 minutes (95% confidence interval, 15.0 to not available). No substantial differences in maternal characteristics were found between individuals with and without contractions. The proposed method for measuring isthmic length provided an objective assessment of the presence and intensity of isthmic contractions. A cutoff of 18 mm in isthmic length allowed for the distinction of pregnant women presenting a contraction. In addition, the study identified a characteristic undulatory pattern in the relaxation of the isthmus in half of the cases with contractions. CONCLUSION: Isthmic contractions are a common occurrence after bladder voiding in the second trimester of pregnancy and may interfere with proper cervical length assessment. We recommend performing cervical assessment at least 20 minutes after bladder voiding to reduce the risk of bias in cervical length measurement and to avoid false images of placenta previa. The new method for measuring isthmic length provides an objective way to assess the presence and intensity of isthmic contractions. Further research is needed to understand the role of isthmic contractions in the physiology of pregnancy and birth.


Assuntos
Placenta Prévia , Nascimento Prematuro , Gravidez , Feminino , Humanos , Útero/diagnóstico por imagem , Colo do Útero/diagnóstico por imagem , Contração Uterina , Ultrassonografia , Medida do Comprimento Cervical/métodos , Segundo Trimestre da Gravidez , Nascimento Prematuro/epidemiologia
2.
Neurocrit Care ; 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095629

RESUMO

BACKGROUND: Management of assisted ventilation and determining the optimal timing for discontinuation presents a significant clinical obstacle in patients affected by neuromuscular (NM) diseases. This study aimed to evaluate the efficacy of ultrasound in appraising diaphragmatic function for predicting the necessity of intubation and determining the opportune moment to discontinue mechanical ventilation (MV) in patients with NM disorders. METHODS: The study was conducted in adult patients with NM diseases requiring inpatient care in the high-dependency neurology ward and the intensive care unit. Ultrasonographic assessment of diaphragmatic excursion (DE) and diaphragmatic thickness fraction (DTF) was conducted at the patient's bedside every 48 h for ventilated patients and every 72 h for nonventilated patients until they were weaned from the ventilator or discharged home. Qualitative data are expressed as percentages or numbers, and quantitative data are represented as mean ± standard deviation. Unpaired t-tests were employed to compare continuous variables, and χ2 tests were used for categorical variables. Contingency table analysis was used to compute relative risks in comparing the baseline DE and DTF with the sequential changes in these values. RESULTS: In cases in which the baseline left DE measured less than 1 cm, the relative risk for the requirement of ventilation was 2.5 times higher, with a confidence interval of 0.62-0.99 (P = 0.19). Notably, a bilateral reduction in DE within the initial 48 h of admission was identified as predictive of need for intubation. When comparing ventilated and nonventilated patients, it was observed that the mean DE values for the left and right sides in ventilated patients (0.74 and 0.79) were significantly lower than those in nonventilated patients (1.3 and 1.66), with corresponding P values of 0.05 and 0.01, respectively. Furthermore, a decline in right DE by more than 50% within 72 h of admission presented a relative risk of 3.3 for the necessity of ventilation, with a confidence interval of 1.29-8.59 (P = 0.01). Duration of ventilation ranged from 2 to 45 days, with an average of 13.14 days, whereas the mean ventilator-free days recorded was 13.57. Notably, a sequential increase in bilateral DE correlated with an extended duration of ventilator-free days. CONCLUSIONS: The presence of a baseline left DE of less than 1 cm, a consecutive decrease in DE measurements within 48 h, and a comparative reduction in right DE of more than 50% within the initial 3 days are indicators associated with the requirement for MV in patients with NM disease. Furthermore, the upward trajectory of DE in mechanically ventilated patients is linked to an increased number of days free from ventilator support, suggesting its potential to forecast earlier weaning.

3.
BMC Med Educ ; 24(1): 15, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172820

RESUMO

BACKGROUND: Ultrasound is a safe and effective diagnostic tool used within several specialties. However, the quality of ultrasound scans relies on sufficiently skilled clinician operators. The aim of this study was to explore the validity of automated assessments of upper abdominal ultrasound skills using an ultrasound simulator. METHODS: Twenty five novices and five experts were recruited, all of whom completed an assessment program for the evaluation of upper abdominal ultrasound skills on a virtual reality simulator. The program included five modules that assessed different organ systems using automated simulator metrics. We used Messick's framework to explore the validity evidence of these simulator metrics to determine the contents of a final simulator test. We used the contrasting groups method to establish a pass/fail level for the final simulator test. RESULTS: Thirty seven out of 60 metrics were able to discriminate between novices and experts (p < 0.05). The median simulator score of the final simulator test including the metrics with validity evidence was 26.68% (range: 8.1-40.5%) for novices and 85.1% (range: 56.8-91.9%) for experts. The internal structure was assessed by Cronbach alpha (0.93) and intraclass correlation coefficient (0.89). The pass/fail level was determined to be 50.9%. This pass/fail criterion found no passing novices or failing experts. CONCLUSIONS: This study collected validity evidence for simulation-based assessment of upper abdominal ultrasound examinations, which is the first step toward competency-based training. Future studies may examine how competency-based training in the simulated setting translates into improvements in clinical performances.


Assuntos
Internato e Residência , Realidade Virtual , Humanos , Competência Clínica , Simulação por Computador , Ultrassonografia , Reprodutibilidade dos Testes
4.
J Therm Biol ; 124: 103925, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39241530

RESUMO

Intramuscular temperature kinetics can provide insightful information for exercise and environmental physiology research. However, currently, there are no consistent method descriptions or guidelines for muscle temperature assessment in the literature. Studies have reported a great variation in muscle temperature assessment, from 1.5 cm under the skin to 4 cm under the muscle fascia. Moreover, a large variation in body composition components among participants exacerbates this issue, changing the depth and the muscle to be tested. For instance, in young adults (25 ± 5 yrs), the thigh subcutaneous fat thickness can vary from 0.11 to 1.69 cm, and vastus lateralis thickness from 1.62 to 3.38 cm; in older adults (68.5 ± 3 yrs), subcutaneous fat thickness plus gastrocnemius medialis thickness can vary from 1.03 to 3.22 cm. This variation results in inconsistent resting muscle temperature profiles and muscle temperature kinetics during and after an exercise or environmental thermal stress interventions (hot or cold). Hence, one fixed size does not fit all. Standardization and consistency in muscle temperature assessment procedures across studies are required to allow a better understanding and translation of the influence of a given stressor (exercise or thermal) on muscle temperature kinetics. This methodological manuscript i) summarizes the differences in muscle temperature assessment procedures and techniques used across different studies, ii) discusses current concerns related to variations in intramuscular needle depth, and subcutaneous fat and muscle thickness when assessing muscle temperature, and iii) suggests a systematic and more robust approach, based on individual body composition characteristics, to be considered when assessing intramuscular temperature.


Assuntos
Músculo Esquelético , Humanos , Composição Corporal , Temperatura Corporal , Exercício Físico/fisiologia , Músculo Esquelético/fisiologia , Gordura Subcutânea/fisiologia
5.
Environ Res ; 234: 116543, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37406720

RESUMO

BACKGROUND: Feto-placental hemodynamic deterioration is a critical contributing factor to fetal growth restriction. Whether PM2.5 oxidative potential (OP) affects feto-placental hemodynamics and what impact is on estimated fetal weight (EFW) have not been fully elucidated. We sought to evaluate the association of PM2.5 OP with EFW and to explore whether feto-placental vascular impedance hemodynamic change is a possible mediator in this association. METHODS: A repeated-measures study was conducted involving sixty pregnant women with at least 26 weeks of follow-up during pregnancy in Guangzhou, China, from September 2017 to October 2018. Daily filter-based PM2.5 samples were prospectively collected from ground monitors, and estimates of OP for PM2.5 and its metallic (OPv-metal) and non-metallic constituents (OPv-nonmental) were determined by dithiothreitol assay. Ultrasound data of fetal growth and umbilical arterial resistance, including estimated fetal weight (EFW), pulsatility index, resistance index, and systolic-to-diastolic ratio, were also obtained during gestation. Generalized estimating equations and polynomial distribution lag models were applied to analyze the associations of maternal exposure to PM2.5 OP with EFW and umbilical artery indices. Causal mediation analysis was used to evaluate the mediating role of umbilical arterial resistance. RESULTS: Prenatal exposure to ambient PM2.5 OP was significantly inversely associated with EFW. The magnitudes of effects of OPv-nonmetal on EFW were larger than those of OPv-metal. Significant mediation for the relationship between PM2.5-related OP and EFW by increased impedance in the umbilical artery was observed, with the estimated percent mediated ranging from 31% to 61%. The estimated percent mediated for OPv-nonmetal was higher than those for OPv-metal. CONCLUSIONS: Findings suggest that increased impedance in the umbilical artery may be one of the potential mediators of the relationship between PM2.5 oxidative potential exposure and low fetal weight.


Assuntos
Peso Fetal , Placenta , Recém-Nascido , Gravidez , Feminino , Humanos , Placenta/diagnóstico por imagem , Idade Gestacional , Recém-Nascido Pequeno para a Idade Gestacional , Ultrassonografia Pré-Natal , Hemodinâmica , Retardo do Crescimento Fetal/etiologia , Resistência Vascular , Material Particulado/toxicidade , Estresse Oxidativo
6.
BMC Pregnancy Childbirth ; 23(1): 583, 2023 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-37573329

RESUMO

BACKGROUND: This study aimed to investigate the factors associated with the antenatal umbilical cord pitch value by ultrasound measurement in late pregnancy. We investigated the factors associated with the umbilical cord pitch value under prenatal ultrasound measurement. METHODS: This study included 528 pregnant women who underwent routine antenatal ultrasound examinations in Ningbo Women and Children's Hospital from December 2020 to August 2021. Their umbilical cord pitch values and diameter, Wharton's jelly thickness, amniotic fluid indexes, umbilical artery blood flow parameters, and other relevant data, such as ages and gestational ages, were measured. Information about delivery methods, placenta, umbilical cord, and neonatal weight were recorded during follow-up. Statistical analysis was performed on the above data, and the factors associated with the pitch values were analyzed by linear regression. RESULTS: This study revealed that cord torsion (p < 0.001, 95% confidence interval [CI]=-34.81 to -19.01), cord entanglement (p < 0.001, 95% CI = 10.71 to 20.11), thickening of Wharton's jelly (p = 0.001, 95% CI = 5.39 to 20.24), and cord edema (p = 0.015, 95%CI = 2.09 to 19.44), gestational age (p = 0.024, 95%CI = 0.14 to 1.89), age of pregnant woman (p = 0.009, 95%CI= -1.15 to -0.16), and neonatal weight (p = 0.011, 95%CI = 0.002 to 0.012) were significantly correlated with the pitch values. CONCLUSION: The umbilical cord pitch value significantly correlated with cord entanglement, cord torsion, cord edema, Wharton's jelly thickening, gestational age, age of the pregnant woman, and neonatal weight. Notably, the pitch value by prenatal ultrasound measurement is predictive of cord morphological abnormalities such as cord entanglement, cord torsion, cord edema, and Wharton's jelly thickening.


Assuntos
Cordão Umbilical , Geleia de Wharton , Recém-Nascido , Criança , Gravidez , Feminino , Humanos , Cordão Umbilical/diagnóstico por imagem , Artérias Umbilicais/diagnóstico por imagem , Placenta , Ultrassonografia
7.
J Obstet Gynaecol Res ; 49(11): 2692-2699, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37635633

RESUMO

STUDY OBJECTIVE: Umbilical cord abnormalities increase neonatal morbidity and mortality. Considering uncertainties about the best time of an antenatal ultrasonography scan to evaluate the umbilical coiling index (UCI), this systematic review was designed to assess the diagnostic accuracy value of antenatal ultrasound assessments to predict abnormal postpartum UCI. METHODS: All observational, cross-sectional, case-control, cohort, and diagnostic accuracy studies up to March 26, 2022, were searched and assessed according to PRISMA guidelines in Ovid, Cochrane, Scopus, PubMed, Web of Science, Embase, Proquest, Science Direct, and Clinical Key databases, and Google Scholar search engine. RESULTS: The total number of 63 190 documents were retrieved from databases. The duplicates (19 272) were removed, 43 918 articles were screened for relevance, and 56 papers were selected for full-text evaluation, resulting in 14 qualified pieces subjected to the quality CASP tools for each type of study. Finally, six articles were evaluated, extracted, and confirmed. Overall, we had 16 evaluations (11 normal pregnancies, 4 gestational diabetes mellitus, and 1 group at risk for small gestational age), from which 9 and 7 were respectively performed in the second and third trimesters. Most of the evaluations considered both hypocoiling and hypercoiling. The sensitivity, specificity, and area under curves (AUCs) change range between the evaluations were 0.09-0.97, 0.59-0.96, and 0.262-0.84, respectively. CONCLUSION: Observing any coiling abnormalities in every trimester, both the second and third, is highly sensitive to predicting abnormal postnatal UCI (pUCI). Conclusively, any detected antenatal abnormality is worth attention. Both trimesters' evaluations are essential, and no superiority is seen for any of them. The systematic review revealed statistical and clinical heterogeneity; a meta-analysis was impossible.


Assuntos
Diabetes Gestacional , Resultado da Gravidez , Feminino , Humanos , Recém-Nascido , Gravidez , Estudos Transversais , Gestantes , Cordão Umbilical/diagnóstico por imagem
8.
BMC Med Educ ; 23(1): 921, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38053134

RESUMO

BACKGROUND: Ultrasound is an essential diagnostic examination used in several medical specialties. However, the quality of ultrasound examinations is dependent on mastery of certain skills, which may be difficult and costly to attain in the clinical setting. This study aimed to explore mastery learning for trainees practicing general abdominal ultrasound using a virtual reality simulator and to evaluate the associated cost per student achieving the mastery learning level. METHODS: Trainees were instructed to train on a virtual reality ultrasound simulator until the attainment of a mastery learning level was established in a previous study. Automated simulator scores were used to track performances during each round of training, and these scores were recorded to determine learning curves. Finally, the costs of the training were evaluated using a micro-costing procedure. RESULTS: Twenty-one out of the 24 trainees managed to attain the predefined mastery level two times consecutively. The trainees completed their training with a median of 2h38min (range: 1h20min-4h30min) using a median of 7 attempts (range: 3-11 attempts) at the simulator test. The cost of training one trainee to the mastery level was estimated to be USD 638. CONCLUSION: Complete trainees can obtain mastery learning levels in general abdominal ultrasound examinations within 3 hours of training in the simulated setting and at an average cost of USD 638 per trainee. Future studies are needed to explore how the cost of simulation-based training is best balanced against the costs of clinical training.


Assuntos
Treinamento por Simulação , Realidade Virtual , Humanos , Competência Clínica , Ultrassonografia , Simulação por Computador , Treinamento por Simulação/métodos , Curva de Aprendizado
9.
BMC Anesthesiol ; 22(1): 5, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-34979932

RESUMO

BACKGROUND: Pulmonary aspiration is a major complication in anesthesia, and various studies have shown that gastric sonography can reliably provide valuable information relative to both the qualitative and quantitative aspects of gastric content. This study aimed to determine the accuracy of ultrasound assessment of gastric content compared between two novice anesthesiologist gastric sonographers. METHODS: This prospective cohort study of two anesthesiologists learning to perform qualitative and quantitative ultrasound assessment of gastric content on healthy volunteers was conducted at Siriraj Hospital (Bangkok, Thailand). This trial was registered with ClinicalTrials.gov (reg. no. NCT04760106). RESULTS: Of the 50 enrolled participants, three were excluded due to study protocol violation. Each anesthesiologist performed a qualitative assessment on 47 participants for an overall total of 94 scans. There were 15 males and 32 females (age 42 ± 11.7 years, weight 61.2 ± 13.1 kg, height 160.7 ± 7.3 cm, and BMI 23.6 ± 4.3 kg/m2). The overall success rate for all gastric content categories was approximately 96%. From antral cross-sectional area measurement, as the ingested volume increased, there was a tendency toward increased deviation from the actual ingested volume. Interrater agreement between anesthesiologists was analyzed using intraclass correlation coefficients (ICCs). A larger fluid volume was found to be associated with a lower level of agreement between the two anesthesiologists. The ICCs were 0.706 (95% CI: -0.125 to 0.931), 0.669 (95% CI: -0.254 to 0.920), 0.362 (95% CI: -0.498 to 0.807) for the 100 ml, 200 ml, and 300 ml fluid volumes, respectively. The mean duration to perform an ultrasound examination for each gastric content category and for the entire examination did not differ significantly between anesthesiologists (p > 0.05). CONCLUSION: Our results indicate that qualitative ultrasound assessment of gastric content is highly accurate and can be easily learned. In contrast, quantification of gastric volume by novice gastric sonographers is more complex and requires more training. TRIAL REGISTRATION: ClinicalTrials.gov no. NCT04760106 Date registered on Feb 11, 2021. Prospectively registered.


Assuntos
Anestesiologistas/estatística & dados numéricos , Conteúdo Gastrointestinal/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Competência Clínica , Estudos de Coortes , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Estudos Prospectivos , Pesquisa Qualitativa , Reprodutibilidade dos Testes , Tailândia
10.
J Perinat Med ; 49(7): 907-914, 2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-33861027

RESUMO

OBJECTIVES: Women with gestational diabetes (GDM) and weight gain during pregnancy above recommended more often give birth to macrosomic children. The goal of this study was to evaluate the diagnostic accuracy of the modified formula for ultrasound assessment of fetal weight created in a pilot study using a similar specimen in comparison to the Hadlock-2 formula. METHODS: This is a prospective, cohort, applicative, observational, quantitative, and analytical study, which included 213 pregnant women with a singleton pregnancy, GDM, and pregnancy weight gain above recommended. Participants were consecutively followed in the time period between July 1st, 2016, and August 31st, 2020. Ultrasound estimations were made within three days before the delivery. Fetal weights estimated using both formulas were compared to the newborns' weights. RESULTS: A total of 133 fetal weight estimations were made. In comparison to the newborns' weight modified formula had significantly smaller deviation in weight estimation compared to the Hadlock-2 formula, higher frequency of deviation within 5% of newborns weights (78.2% [95% CI=0.74-0.83] vs. 60.2%), smaller frequency of deviations from 5 to 10% (19.5 vs. 33.8%) and above 10%, which was even more significant among macrosomic children. There were 36/50 (72%) correctly diagnosed cases of macrosomia by modified and 33/50 (66%) by Hadlock-2 formula. Area under the curve (AUC) for the modified formula was 0.854 (95% CI=0.776-0.932), and for the Hadlock-2 formula 0.824 (95% CI=0.740-0.908). The positive predictive value of the modified formula was 81.81%, the negative 97.91%. CONCLUSIONS: In cases of greater fetal weights, the modified formula showed greater precision.


Assuntos
Regras de Decisão Clínica , Diabetes Gestacional/fisiopatologia , Macrossomia Fetal/diagnóstico por imagem , Ganho de Peso na Gestação , Ultrassonografia Pré-Natal/métodos , Adulto , Área Sob a Curva , Feminino , Macrossomia Fetal/etiologia , Humanos , Recém-Nascido , Masculino , Modelos Estatísticos , Valor Preditivo dos Testes , Gravidez , Estudos Prospectivos
11.
Clin Otolaryngol ; 46(6): 1304-1309, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34255927

RESUMO

INTRODUCTION: Unilateral vocal cord paralysis (UVCP) is a known complication of thyroid surgery, due to iatrogenic recurrent laryngeal nerve injury, with reported rates of 2%-5% in children. The gold standard for assessing vocal cord function in flexible nasendoscopy (FNE) examination, which is considered high-risk for contraction of the COVID-19 virus. Intraoperative ultrasonographic assessment (IUA) of vocal cord function is a non-invasive and relatively simple procedure performed in a supine position, performed during spontaneous breathing, following reversed anaesthesia, while the patient is still sedated. OBJECTIVES: To evaluate the validity of IUA modality in children undergoing thyroidectomy and to compare it to the standard FNE. DESIGN: A prospective double-blind study covering 24 months (March 2019-March 2021). Twenty thyroid lobectomies were performed, during 15 surgeries. Vocal cord function was assessed three times: Pre-operatively by FNE, intraoperative (IUA) following extubation, and a second FNE on the first post-operative day. SETTINGS: A tertiary paediatric hospital. RESULTS: The overall accuracy of IUA results in our study was 92%. IUA sensitivity, specificity, positive and negative predictive values were 100%, 89%, 33% and 100%, respectively. Patient's age demonstrated borderline significance (p = .08). The resident's experience was associated with a better correlation between IUA and FNE results (p < .05). CONCLUSIONS: IUA of vocal cord motion has a high accuracy rate for detection of iatrogenic vocal cord paralysis, similar to FNE. It is easily learned by residents, well-tolerated by children, and it provides a safe and valid alternative modality while ensuring the safety of the medical staff in treating patients, especially in times of COVID-19 pandemic.


Assuntos
COVID-19/epidemiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Tireoidectomia , Ultrassonografia/métodos , Paralisia das Pregas Vocais/diagnóstico por imagem , Adolescente , Criança , Método Duplo-Cego , Feminino , Humanos , Doença Iatrogênica , Masculino , Monitorização Intraoperatória , Pandemias , Estudos Prospectivos , SARS-CoV-2
12.
J Ultrasound Med ; 38(11): 2955-2962, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30924192

RESUMO

OBJECTIVES: Although gastric emptying rate (GER) influences incretin response and nutrient absorption, both defective in people with cystic fibrosis (CF), there are few studies in this group, and the circadian rhythm is unknown. We employed an ultrasonographic technique to assess GER in people with CF following liquid and mixed meals and also evaluated the circadian rhythm, compared to normal controls. METHODS: Thirteen pancreatic-insufficient adults with CF and 10 healthy controls underwent a fasting oral glucose tolerance test (OGTT; liquid meal) and on a second visit underwent a fasting mixed meal test (MMT) thrice on the same day. GER was measured during the OGTT and each MMT using a 3.5-MHz abdominal transducer probe at baseline and 30, 60, 90, and 120 minutes. RESULTS: Controls had normal GER for both OGTT and MMT. Compared to controls, people with CF had delayed GER60 for OGTT (mean 46%), which increased with time (P = .001), and also delayed GER90 for MMT in the morning (mean 56%), afternoon (58%), and evening (59%). The GER in the control group was better at all time points throughout the day compared to patients with CF. CONCLUSIONS: This is the first study to use ultrasonography, an inexpensive bedside technique, to assess GER in adults with CF. For the first time, we have shown that adults with CF have delayed GER for both liquid and mixed meals, and this delay continues throughout the day.


Assuntos
Fibrose Cística/fisiopatologia , Esvaziamento Gástrico/fisiologia , Ultrassonografia/métodos , Adulto , Feminino , Humanos , Masculino , Testes Imediatos , Estômago/diagnóstico por imagem , Estômago/fisiologia
13.
Ultrasound Obstet Gynecol ; 46(3): 312-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25580809

RESUMO

OBJECTIVE: To study the effect of initial simulation-based transvaginal sonography (TVS) training compared with clinical training only, on the clinical performance of residents in obstetrics and gynecology (Ob-Gyn), assessed 2 months into their residency. METHODS: In a randomized study, new Ob-Gyn residents (n = 33) with no prior ultrasound experience were recruited from three teaching hospitals. Participants were allocated to either simulation-based training followed by clinical training (intervention group; n = 18) or clinical training only (control group; n = 15). The simulation-based training was performed using a virtual-reality TVS simulator until an expert performance level was attained, and was followed by training on a pelvic mannequin. After 2 months of clinical training, one TVS examination was recorded for assessment of each resident's clinical performance (n = 26). Two ultrasound experts blinded to group allocation rated the scans using the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale. RESULTS: During the 2 months of clinical training, participants in the intervention and control groups completed an average ± SD of 58 ± 41 and 63 ± 47 scans, respectively (P = 0.67). In the subsequent clinical performance test, the intervention group achieved higher OSAUS scores than did the control group (mean score, 59.1% vs 37.6%, respectively; P < 0.001). A greater proportion of the intervention group passed a pre-established pass/fail level than did controls (85.7% vs 8.3%, respectively; P < 0.001). CONCLUSION: Simulation-based ultrasound training leads to substantial improvement in clinical performance that is sustained after 2 months of clinical training. © 2015 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Competência Clínica , Ginecologia/educação , Internato e Residência , Obstetrícia/educação , Treinamento por Simulação , Ultrassonografia Pré-Natal , Adulto , Dinamarca , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Gravidez , Método Simples-Cego
14.
Ultrasound Obstet Gynecol ; 43(4): 444-51, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24105723

RESUMO

OBJECTIVE: To explore the association between clinical training characteristics and trainees' level of confidence in performing ultrasound scans independently. METHODS: A cross-sectional e-survey was distributed to members of the national societies of junior obstetricians/gynecologists in Denmark, Sweden and Norway (n = 973). Multiple linear regression models were used to explore the effect that amount of time spent in specialized ultrasound units and clinical experience had on trainees' confidence in performing ultrasonography independently. Exploratory factor analysis was used to identify factors that contributed to trainees' confidence in performing ultrasonography. Trainees' ultrasound confidence was finally compared with their expected levels of performance. RESULTS: Of the 682 respondents (response rate 70.1%), 621 met the inclusion criteria. Clinical experience and time spent in specialized ultrasound units were predictors of trainees' confidence in performing ultrasonography independently (P < 0.001). Trainees required more than 24 months of clinical experience and 12-24 days of training in specialized ultrasound units in order to feel confident about performing transvaginal and transabdominal ultrasound scans independently. Three factors were related to ultrasound confidence: technical aspects, image perception and integration of scan into patient care. There were significant differences between trainees' level of confidence and their expected levels of performance (P < 0.001). CONCLUSIONS: Clinical experience and time spent in specialized ultrasound units were predictors of trainees' confidence in performing ultrasonography independently. Discrepancies between trainees' confidence and their expected levels of performance raised concerns about the adequacy of current ultrasound training programs.


Assuntos
Competência Clínica , Ginecologia , Obstetrícia , Ultrassom , Adulto , Atitude do Pessoal de Saúde , Competência Clínica/normas , Estudos Transversais , Dinamarca , Educação Médica Continuada , Educação de Pós-Graduação em Medicina , Feminino , Ginecologia/educação , Ginecologia/normas , Humanos , Masculino , Pessoa de Meia-Idade , Noruega , Obstetrícia/educação , Obstetrícia/normas , Gravidez , Inquéritos e Questionários , Suécia , Ultrassom/educação , Ultrassom/normas
15.
Ultrasound Obstet Gynecol ; 43(4): 437-43, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23996613

RESUMO

OBJECTIVES: To explore the reliability and validity of a recently developed instrument for assessment of ultrasound operator competence, the Objective Structured Assessment of Ultrasound Skills (OSAUS). METHODS: Three groups of 10 doctors with different levels of ultrasound experience in obstetrics and gynecology were included. The novices had less than 1 month of experience, the intermediate group had 12-60 months of experience and the senior participants were all consultants. Fifteen participants performed transabdominal fetal biometry and the other 15 participants performed systematic transvaginal gynecological ultrasound scans. All scans were video-recorded and assessed by two blinded consultants using the OSAUS scale. The OSAUS scores were compared between the groups using the Kruskal-Wallis test, and pass/fail scores were determined using the contrasting-groups method of standard setting. RESULTS: For the transabdominal fetal biometry examinations, the mean ± SD OSAUS scores of the novices, intermediates and senior participants were 1.5 ± 0.4, 3.3 ± 0.6 and 4.4 ± 0.4, respectively (P = 0.003). For the systematic transvaginal scans, the mean ± SD OSAUS scores of the novices, intermediates and senior participants were 1.8 ± 0.2, 3.1 ± 0.1 and 3.9 ± 0.5, respectively (P = 0.003). Post-hoc comparisons showed significant differences between each of the groups for both types of scans. The pass/fail score was 2.5 for the transvaginal scan and 3.0 for the transabdominal biometry examinations. The inter-rater reliability was 0.89. CONCLUSIONS: Ultrasound competence can be assessed in a reliable and valid way using the OSAUS scale. The pass/fail scores may be used to help determine when trainees are qualified for independent practice.


Assuntos
Biometria , Competência Clínica/normas , Ginecologia , Obstetrícia , Ultrassom/educação , Ultrassonografia/normas , Biometria/métodos , Feminino , Ginecologia/educação , Ginecologia/normas , Humanos , Internato e Residência , Masculino , Obstetrícia/normas , Médicos , Gravidez , Reprodutibilidade dos Testes
16.
Ultrasound Obstet Gynecol ; 43(4): 365-71, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24615948

RESUMO

OBJECTIVE: To compare the efficacy of two standard surgical procedures for post-hysterectomy vaginal vault prolapse in patients with levator ani avulsion. METHODS: This was a single-center, randomized interventional trial, of two standard surgical procedures for post-hysterectomy vaginal vault prolapse: Prolift Total vs unilateral vaginal sacrospinous colpopexy with native tissue vaginal repair (sacrospinous fixation, SSF), during the period from 2008 to 2011. Entry criteria included at least two-compartment prolapse, as well as complete unilateral or bilateral levator ani avulsion injury. The primary outcome was anatomical failure based on clinical and ultrasound assessment. Failure was defined clinically, according to the Pelvic Organ Prolapse Quantification system, as Ba, C or Bp at the hymen or below, and on translabial ultrasound as bladder descent to 10 mm or more below the lower margin of the symphysis pubis on maximum Valsalva maneuver. Secondary outcomes were evaluation of continence, sexual function and prolapse symptoms based on validated questionnaires. RESULTS: During the study period, 142 patients who were post-hysterectomy underwent surgery for prolapse in our unit; 72 of these were diagnosed with an avulsion injury and were offered participation in the study. Seventy patients were randomized into two groups: 36 in the Prolift group and 34 in the SSF group. On clinical examination at 1-year follow-up, we observed one (3%) case of anatomical failure in the Prolift group and 22 (65%) in the SSF group (P < 0.001). Using ultrasound criteria, there was one (2.8%) failure in the Prolift group compared with 21 (61.8%) in the SSF group (P < 0.001). The postoperative POPDI (Pelvic Organ Prolapse Distress Inventory) score for subjective outcome was 15.3 in the Prolift group vs 21.7 in the SSF group (P = 0.16). CONCLUSION: In patients with prolapse after hysterectomy and levator ani avulsion injury, SSF has a higher anatomical failure rate than does the Prolift Total procedure at 1-year follow-up.


Assuntos
Doenças do Ânus/cirurgia , Procedimentos Cirúrgicos em Ginecologia/métodos , Histerectomia Vaginal/efeitos adversos , Dor/cirurgia , Prolapso de Órgão Pélvico/cirurgia , Complicações Pós-Operatórias/cirurgia , Telas Cirúrgicas , Vagina/cirurgia , Idoso , Doenças do Ânus/complicações , Doenças do Ânus/diagnóstico por imagem , Coito , Feminino , Humanos , Pessoa de Meia-Idade , Dor/complicações , Dor/diagnóstico por imagem , Diafragma da Pelve/cirurgia , Prolapso de Órgão Pélvico/diagnóstico por imagem , Prolapso de Órgão Pélvico/etiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Inquéritos e Questionários , Resultado do Tratamento , Ultrassonografia , Incontinência Urinária por Estresse/etiologia , Vagina/diagnóstico por imagem , Vagina/fisiopatologia , Manobra de Valsalva
17.
World J Cardiol ; 16(6): 306-309, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38993587

RESUMO

This editorial discusses the manuscript by Di Maria et al, published in the recent issue of the World Journal of Cardiology. We here focus on the still elusive pathophysiological mechanisms underlying cardio-renal syndrome (CRS), despite its high prevalence and the substantial worsening of both kidney function and heart failure. While the measure of right atrial pressure through right cardiac catheterization remains the most accurate albeit invasive and costly procedure, integrating bedside ultrasound into diagnostic protocols may substantially enhance the staging of venous congestion and guide therapeutic decisions. In particular, with the assessment of Doppler patterns across multiple venous districts, the Venous Excess Ultrasound (VExUS) score improves the management of fluid overload and provides insight into the underlying factors contributing to cardio-renal interactions. Integrating specific echocardiographic parameters, particularly those concerning the right heart, may thus improve the VExUS score sensitivity, offering perspective into the nuanced comprehension of cardio-renal dynamics. A multidisciplinary approach that consistently incorporates the use of ultrasound is emerging as a promising advance in the understanding and management of CRS.

18.
Infect Agent Cancer ; 18(1): 34, 2023 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-37245026

RESUMO

OBJECTIVE: to evaluate the efficacy of US, both qualitatively and semi-quantitatively, in the selection of treatment for the Covid-19 patient, using patient triage as the gold standard. METHODS: Patients admitted to the Covid-19 clinic to be treated with monoclonal antibodies (mAb) or retroviral treatment and undergoing lung ultrasound (US) were selected from the radiological data set between December 2021 and May 2022 according to the following inclusion criteria: patients with proven Omicron variant and Delta Covid-19 infection; patients with known Covid-19 vaccination with at least two doses. Lung US (LUS) was performed by experienced radiologists. The presence, location, and distribution of abnormalities, such as B-lines, thickening or ruptures of the pleural line, consolidations, and air bronchograms, were evaluated. The anomalous findings in each scan were classified according to the LUS scoring system. Nonparametric statistical tests were performed. RESULTS: The LUS score median value in the patients with Omicron variant was 1.5 (1-20) while the LUS score median value in the patients with Delta variant was 7 (3-24). A difference statistically significant was observed for LUS score values among the patients with Delta variant between the two US examinations (p value = 0.045 at Kruskal Wallis test). There was a difference in median LUS score values between hospitalized and non-hospitalized patients for both the Omicron and Delta groups (p value = 0.02 on the Kruskal Wallis test). For Delta patients groups the sensitivity, specificity, positive and negative predictive values, considering a value of 14 for LUS score for the hospitalization, were of 85.29%, 44.44%, 85.29% and 76.74% respectively. CONCLUSIONS: LUS is an interesting diagnostic tool in the context of Covid-19, it could allow to identify the typical pattern of diffuse interstitial pulmonary syndrome and could guide the correct management of patients.

19.
Anaesth Crit Care Pain Med ; 41(2): 101024, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35121186

RESUMO

PURPOSE: Ultrasound (US) allows non-invasive repeated assessments of diaphragmatic excursion (DE) and thickening fraction (DTF) at the bedside, reflecting diaphragmatic dysfunction (DD). We aimed at determining the prevalence and time-course of DD following elective thoracic surgery and the association with postoperative complications. MATERIAL AND METHODS: Prospective, single-centre, observational study with consecutive patients undergoing thoracic surgery. DE/DTF were measured by two observers blinded to each other at 3 different time-points: prior to surgery, immediately after extubation and on postoperative day 3. The changes in DE/DTF of both hemi-diaphragms over time were compared according to the side (operated/non-operated) using a two-way-ANOVA. The association with postoperative complications was assessed using logistic regression. RESULTS: Fifty patients, 60% males, aged 60 ± 15 years were included. Surgical procedures included lobectomy (n = 30), wedge-resection (n = 17) or pneumonectomy (n = 3). On the operated side, we observed a decrease in DE/DTF at D0 (-0.71 ± 0.12 mm, P < 0.05; -44 ± 30%, P < 0.05) and D3 (-0.82 ± 0.19 mm, P < 0.05; -39 ± 19%, P < 0.05) with respect to preoperative and non-operated side values over the study period. Persistent DD on the operated side was associated with an increased risk of lung infection (OR: 9.0, 95% CI [1.92-65.93], P = 0.001), ICU-admission (OR: 3.9, 95% CI [1.10-15.53], P = 0.04) according to univariate analysis and a prolonged length in hospital (OR: 1.3, 95% CI [1.1-1.7], P = 0.016) according to multivariate analysis. CONCLUSIONS: Thoracic surgery generates DD mainly observed on the operated side, which persists at least up to postoperative D3 and is associated with an increase in hospital stay.


Assuntos
Diafragma , Ultrassom , Diafragma/diagnóstico por imagem , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Complicações Pós-Operatórias/epidemiologia , Prevalência , Estudos Prospectivos
20.
World J Clin Cases ; 10(18): 6082-6090, 2022 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-35949825

RESUMO

BACKGROUND: Enhanced recovery after surgery advocates that consuming carbohydrates two hours before anesthesia is beneficial to the patient's recovery. Patients with diabetes are prone to delayed gastric emptying. Different guidelines for preoperative carbohydrate consumption in patients with diabetes remain controversial due to concerns about the risk of regurgitation, aspiration and hyperglycemia. Ultrasonic gastric volume (GV) assessment and blood glucose monitoring can comprehensively evaluate the safety and feasibility of preoperative carbohydrate intake in type 2 diabetes (T2D) patients. AIM: To evaluate the impact of preoperative carbohydrate loading on GV before anesthesia induction in T2D patients. METHODS: Patients with T2D receiving surgery under general anesthesia from December 2019 to December 2020 were included. A total of 78 patients were randomly allocated to 4 groups receiving 0, 100, 200, or 300 mL of carbohydrate loading 2 h before anesthesia induction. Gastric volume per unit weight (GV/W), Perlas grade, changes in blood glucose level, and risk of reflux and aspiration were evaluated before anesthesia induction. RESULTS: No significant difference was found in GV/W among the groups before anesthesia induction (P > 0.05). The number of patients with Perlas grade II and GV/W > 1.5 mL/kg did not differ among the groups (P > 0.05). Blood glucose level increased by > 2 mmol/L in patients receiving 300 mL carbohydrate drink, which was significantly higher than that in groups 1 and 2 (P < 0.05). CONCLUSION: Preoperative carbohydrate loading < 300 mL 2 h before induction of anesthesia in patients with T2D did not affect GV or increase the risk of reflux and aspiration. Blood glucose levels did not change significantly with preoperative carbohydrate loading of < 200 mL. However, 300 mL carbohydrate loading may increase blood glucose levels in patients with T2D before induction of anesthesia.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa