Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Rev Cardiovasc Med ; 24(8): 233, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39076725

RESUMO

Background: In secondary mitral regurgitation (SMR), effective regurgitant orifice area by the proximal isovelocity surface area method ( EROA PISA ) evaluation might cause an underestimation of regurgitant orifice area because of its ellipticity compared with vena contracta area (VCA). We aimed to reassess the SMR severity using VCA-related parameters and EROA PISA . Methods: The three-dimensional transesophageal echocardiography data of 128 patients with SMR were retrospectively analyzed; the following parameters were evaluated: EROA PISA , anteroposterior and mediolateral vena contracta widths (VCWs) of VCA (i.e., VCW AP and VCW ML ), VCW Average calculated as ( VCW AP + VCW ML )/2, and VCA Ellipse calculated as π × ( VCW AP /2) × ( VCW ML /2). Severe SMR was defined as ≥ 0.39 cm 2 . Results: The mean age of the patients was 77.0 ± 8.9 years, and 78 (60.9%) were males. Compared with EROA PISA (r = 0.801), VCW Average (r = 0.940) and VCA Ellipse (r = 0.980) were strongly correlated with VCA. On receiver-operating characteristic curve analysis, VCW Average and VCA Ellipse had C-statistics of 0.981 (95% confidence interval [CI], 0.963-1.000) and 0.985 (95% CI, 0.970-1.000), respectively; these were significantly higher than 0.910 (95% CI, 0.859-0.961) in EROA PISA (p = 0.007 and p = 0.003, respectively). The best cutoff values for severe SMR of VCW Average and VCA Ellipse were 0.78 cm and 0.42 cm 2 , respectively. The prevalence of severe SMR significantly increased with an increase in EROA PISA (38 of 88 [43.2%] patients with EROA PISA < 0.30 cm 2 , 21 of 24 [87.5%] patients with EROA PISA = 0.30-0.40 cm 2 , and 16 of 16 [100%] patients with EROA PISA ≥ 0.40 cm 2 [Cochran-Armitage test; p < 0.001]). Among patients with EROA PISA < 0.30 cm 2 , SMR severity based on VCA was accurately reclassified using VCW Average (McNemar's test; p = 0.505) and VCA Ellipse (p = 0.182). Conclusions: Among patients who had SMR with EROA PISA of < 0.30 cm 2 , suggestive of moderate or less SMR according to current guidelines, > 40% had discordantly severe SMR based on VCA. VCW Average and VCA Ellipse values were useful for identifying severe SMR based on VCA in these patients.

2.
Echocardiography ; 38(8): 1307-1313, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34286878

RESUMO

PURPOSE: Transthoracic echocardiography (TTE) provides noninvasively quantitative assessment of aortic regurgitation (AR) severity, but its diagnostic accuracy depends on image quality. Two-dimensional transesophageal echocardiography (TEE) is a semi-invasive procedure that is excellent in evaluating AR mechanism. However, quantitative assessment may be challenging due to restrictions in probe manipulation. This study aimed to investigate the diagnostic value of three-dimensional TEE to measure the vena contracta area (3DVCA) of AR. METHODS: The subjects comprised 62 patients (age, 65 ± 16 years) whose AR was evaluated using TEE. The 3DVCA and semi-quantitative TEE parameters, such as the ratio of AR jet width to left ventricular outflow tract (jet/LVOT) and the vena contracta width (VCW) of AR jet, were compared using angiography grade and quantitative TTE measurements including regurgitant volume (RVol) and effective regurgitant orifice area (EROA). The diagnostic accuracy was determined using receiver operating characteristic (ROC) analysis, and the reproducibility of 3DVCA was also evaluated. RESULTS: In 3DVCA, less overlap between angiography grades were observed. Correlation with RVol or EROA was better in 3DVCA than in Jet/LVOT or VCW. The area under the ROC curve was .737 for jet/LVOT, .773 for VCW, and .849 for 3DVCA, respectively. The optimal cutoff value of 3DVCA was ≥.31 cm2 for grading severe AR. Inter- and intra-observer reproducibility of 3DVCA were .92 and .97, respectively. CONCLUSIONS: The 3DVCA method using TEE showed high diagnostic accuracy and reproducibility. 3DVCA deserves use in accurately assessing AR severity, especially in patients who present difficulty in quantitative Doppler assessment using TTE.


Assuntos
Insuficiência da Valva Aórtica , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
3.
Echocardiography ; 36(2): 370-375, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30548321

RESUMO

INTRODUCTION: Rheumatic mitral stenosis (MS) is an important health issue in developing countries. Assessment of the correct mitral valve area (MVA) is essential for the timing of intervention. Most of the parameters for the assessment of rheumatic MS are derived from Two-dimensional (2D) echocardiography. Three-dimensional (3D) echocardiography is commonly used in our daily practice at the present time. The aim of this study was to assess the value of 3D echocardiography mitral valve vena contracta area (VCA) in predicting the severity of Rheumatic MS by comparing 3D planimetry. METHODS: The patients, who had been diagnosed as mild, moderate, and severe rheumatic MS with conventional methods (pressure half time, planimetry) by 2D transesophageal echocardiography (TEE)/ transthoracic echocardiography (TTE), underwent 3D TEE evaluation. Also, the patients who had an atrial fibrillation and more than moderate aortic regurgitation were included in the study. 3D TEE full volume mitral valve VCA was measured in end-diastole during its largest dimensions. 3D TEE full volume and 3D zoom MVA planimetry were measured at the end-diastole during the mitral valve`s largest opening. RESULTS: We studied 40 patients (the mean age: 51.1 ± 11.6 years, 31 females) with rheumatic MS. 3D TEE VCA was found to be highly correlated with the 3D TEE MVA (r = 0.82, P < 0.001). CONCLUSION: Our study findings provide evidence that 3D TEE mitral valve VCA can be additionally used in detecting the severity of rheumatic MS.


Assuntos
Ecocardiografia Tridimensional/métodos , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/etiologia , Cardiopatia Reumática/complicações , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Estenose da Valva Mitral/patologia , Reprodutibilidade dos Testes , Cardiopatia Reumática/patologia , Índice de Gravidade de Doença
4.
J Cardiothorac Vasc Anesth ; 33(10): 2647-2651, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31320261

RESUMO

OBJECTIVES: Increased utilization and highly variable costs seen with percutaneous mitral valve edge-to-edge repair have made cost cutting strategies of significant interest. Mitral regurgitation etiology, the number of devices used, and experience all play a role in variability. Currently a paucity of data exists in predicting the number of devices. Any associations found between echocardiography parameters and the number of devices used could help with pre-procedure planning and device placement strategies, ultimately reducing variability and costs. DESIGN: In this retrospective analysis the authors evaluated the ability of established and novel three-dimensional (3D) mitral regurgitation measures, namely 3D vena contracta area and vena contracta length, to predict the number of devices used. Other factors evaluated include mitral valve area and ejection fraction. All factors were compared using the Mann Whitney rank sum tests. PARTICIPANTS: Patients over 18 years old undergoing the MitraClip procedure. SETTING: Catheterization Laboratory. MAIN RESULTS: No relationship was found between 3D parameters and the number of devices used, but mitral valve area was strongly associated with the use of multiple devices. CONCLUSION: The 3D parameters of interest were not associated with the use of multiple devices, but the mitral valve area was associated. Further studies are needed to determine if this relationship is predictive.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia Transesofagiana/métodos , Imageamento Tridimensional/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Previsões , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
5.
Cardiovasc Ultrasound ; 16(1): 1, 2018 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-29310672

RESUMO

BACKGROUND: Percutaneous mitral valve repair (PMVR) is increasingly performed in patients with severe mitral regurgitation (MR). Post-procedural MR grading is challenging and an unsettled issue. We hypothesised that the direct planimetry of vena contracta area (VCA) by 3D-transoesophageal echocardiography allows quantifying post-procedural MR and implies further prognostic relevance missed by the usual ordinal scale (grade I-IV). METHODS: Based on a single-centre PMVR registry containing 102 patients, the association of VCA reduction and patients' functional capacity measured as six-minute walk distance (6 MW) was evaluated. 3D-colour-Doppler datasets were available before, during and 4 weeks after PMVR. RESULTS: Twenty nine patients (age 77.0 ± 5.8 years) with advanced heart failure (75.9% NYHA III/IV) and severe degenerative (34%) or functional (66%) MR were eligible. VCA was reduced in all patients by PMVR (0.99 ± 0.46 cm2 vs. 0.22 ± 0.15 cm2, p < 0.0001). It remained stable after median time of 33 days (p = 0.999). 6 MW improved after the procedure (257.5 ± 82.5 m vs. 295.7 ± 96.3 m, p < 0.01). Patients with a decrease in VCA less than the median VCA reduction showed a more distinct improvement in 6 MW than patients with better technical result (p < 0.05). This paradoxical finding was driven by inferior results in very large functional MR. CONCLUSIONS: VCA improves the evaluation of small residual MR. Its post-procedural values remain stable during a short-term follow-up and imply prognostic information for the patients' physical improvement. VCA might contribute to a more substantiated estimation of treatment success in the heterogeneous functional MR group.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Prognóstico , Recuperação de Função Fisiológica , Sistema de Registros , Instrumentos Cirúrgicos
6.
Echocardiography ; 35(5): 695-706, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29420834

RESUMO

Echocardiographic 3D-guided 2D planimetry can improve the accuracy of valvular disease assessment. Acquisition of 3D pyramidal dataset allows subsequent multiplanar reconstruction with accurate orthogonal plane alignment to obtain the correct borders of an anatomic orifice or flow area. Studies examining the 3D-guided 2D planimetry approach in left-sided valvular heart disease were identified and reviewed. The strongest evidence exists for estimating mitral valve area in patients with rheumatic mitral valve stenosis and vena contracta area in patients with mitral regurgitation (both primary and secondary). 3D-guided approach showed excellent feasibility and reproducibility in most studies, as well as time efficiency and good correlation with reference and comparator methods. Therefore, 3D-guided 2D planimetry can be used as an important clinical tool in quantifying left-sided valvular heart disease, especially mitral valve disorders.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana , Doenças das Valvas Cardíacas/diagnóstico , Valva Mitral/diagnóstico por imagem , Ecocardiografia/métodos , Humanos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
7.
Echocardiography ; 34(5): 683-689, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28317206

RESUMO

AIMS: Evaluation of eccentric mitral regurgitation (MR) remains extremely difficult and the role played by its etiology, functional or degenerative, is not well understood. This study aimed to demonstrate the value of three-dimensional transesophageal echocardiography (3DTEE) in the evaluation of eccentric MR identifying geometric differences in the vena contracta area between functional and degenerative etiologies. METHODS AND RESULTS: We studied 61 patients with eccentric MR (30 functional and 31 degenerative). Regurgitant orifice area was determined by the two-dimensional proximal isovelocity surface area (2DPISA) and the 3DTEE methods. The ratio between maximum and minimum lengths of the vena contracta was calculated in each patient. Effective regurgitant orifice area by the 2DPISA method was smaller than that estimated by 3DTEE (0.56±0.21 vs 0.72±0.25 cm2 ). A better correlation between both methods was seen in degenerative mitral regurgitation (DMR; r=.83), with a mean underestimation of 8.2% by the 2DPISA method. A much worse correlation was found in functional mitral regurgitation (FMR; r=.39), where a mean underestimation by the 2DPISA method of 29.1% was observed. There was a more elongated and curved vena contracta in FMR compared to that in DMR (length ratio: 3.4±1.0 vs 2.2±0.7, P<.0001). CONCLUSION: Three-dimensional transesophageal echocardiography identifies a more elongated regurgitant orifice in eccentric FMR compared to that in eccentric DMR. This difference may explain the greater underestimation of effective regurgitant orifice area by the 2DPISA method in FMR. High-quality 3DTEE analysis of vena contracta area would be a highly recommended alternative.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Insuficiência da Valva Mitral/etiologia , Prolapso da Valva Mitral/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Echocardiography ; 34(1): 87-93, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27699852

RESUMO

INTRODUCTION: Quantification of mitral regurgitation (MR) by two-dimensional (2D) transthoracic echocardiography (TTE) is based on the analysis of the proximal flow convergence (PFC) and the "vena contracta" (VC). This method assumes geometries and can be misleading. In contrast, three-dimensional (3D) echocardiography directly measures flow volumes and does not assume geometries, which allows for more accurate MR evaluation. AIMS: To report the 3D transesophageal echocardiography (3DTEE) feasibility for MR quantification and evaluate its concordance with 2D echo. METHODS: Twenty-seven consecutive patients undergoing 2D and 3DTEE for presurgical MR evaluation were studied prospectively. MR quantification was performed by classical 2D methods based on PFC. Diameters of the VC in orthogonal planes by 3DTEE were estimated, establishing the VC sphericity index as well as VC area (VCA) by direct planimetry. In case of multiple jets, we calculated the sum of the VCA. RESULTS: MR assessment by 3DTEE was feasible. An adequate concordance between VC measurements by 2D methods (TTE and TEE) was observed; however, there was a poor correlation when compared with 3DTEE. The sphericity index of the VC was: 2.08 (±0. 72), reflecting a noncircular VC. CONCLUSIONS: 3DTEE is a feasible method for the assessment of the MR true morphology, allowing a better quantification of MR without assuming any geometry. This method revealed the presence of multiple jets, potentially improving MR evaluation and leading to changes in medical decision when compared to 2D echo assessment.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Mitral/diagnóstico , Valva Mitral/diagnóstico por imagem , Ecocardiografia Doppler em Cores/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
9.
Herz ; 42(3): 241-254, 2017 May.
Artigo em Alemão | MEDLINE | ID: mdl-28229203

RESUMO

Besides providing spatial anatomic information on heart valves, real-time three-dimensional echocardiography (3DE) combined with color Doppler has the potential to overcome the limitations of flow quantification inherent to conventional 2D color Doppler methods. Recent studies validated the application of color Doppler 3DE (cD-3DE) for the quantification of regurgitation flow based on the vena contracta area (VCA) and the proximal isovelocity surface area (PISA) methods. Particularly the assessment of VCA by cD-3DE led to a change of paradigm by understanding of the VCA as being strongly asymmetric in the majority of patients and etiologies. This review provides a comprehensive description of the different concepts of cD-3DE-based flow quantification in the setting of different valvular heart diseases and their presentation in recent guidelines.


Assuntos
Cardiologia/normas , Ecocardiografia Tridimensional/normas , Medicina Baseada em Evidências/normas , Doenças das Valvas Cardíacas/diagnóstico por imagem , Guias de Prática Clínica como Assunto , Radiologia/normas , Índice de Gravidade de Doença , Sistemas Computacionais , Alemanha
10.
Echocardiography ; 32(6): 1022-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25903919

RESUMO

We present the two-dimensional echocardiographic findings of tricuspid valve prolapse with mid-to-late systolic tricuspid regurgitation and describe the incremental value provided by live/real time three-dimensional transthoracic echocardiography. We also discuss a potential pitfall when assessing the severity of regurgitation in this setting.


Assuntos
Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Prolapso da Valva Tricúspide/complicações , Prolapso da Valva Tricúspide/diagnóstico por imagem , Feminino , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
J Cardiothorac Vasc Anesth ; 28(2): 417-22, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24508019

RESUMO

Recent evidence has shown that moderate mitral regurgitation is common and clinically relevant in patients presenting for surgical and transcatheter aortic valve replacement for aortic stenosis. Prospective multicenter clinical trials are now indicated to resolve the clinical equipoise about whether or not mitral valve intervention also is indicated at the time of aortic valve intervention. Advances in three-dimensional transesophageal echocardiography, transcatheter mitral interventions, and surgical aortic valve replacement, including the advent of sutureless valves, likely will expand the therapeutic possibilities for moderate mitral regurgitation in the setting of aortic valve interventions for severe aortic stenosis.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Medicina Baseada em Evidências , Guias como Assunto , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Estenose da Valva Aórtica/complicações , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Insuficiência da Valva Mitral/complicações
13.
J Cardiothorac Vasc Anesth ; 28(1): 189-193, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24440010

RESUMO

Incidental moderate mitral regurgitation (MR) in patients presenting for coronary artery bypass grafting (CABG) is not only common but also probably adversely affects clinical outcome. The echocardiographic evaluation of incidental MR must be comprehensive and integrated, as it remains a cornerstone in management decisions. Current guidelines support surgical mitral intervention in this setting as a reasonable option, reflecting clinical equipoise towards moderate MR in the setting of planned CABG. There are currently 2 major randomized trials in progress that will test whether surgical correction of moderate MR combined with CABG improves major clinical outcomes as compared to CABG alone. These landmark trials will be completed in the near future. In the interim, significant progress in the fields of cardiac resynchronization therapy, transcatheter mitral valve intervention, and minimally invasive mitral valve surgery promise to affect the management alternatives for moderate MR in patients undergoing CABG regardless of operative risk. It is likely that in the coming decade there will be less tolerance for incidental moderate MR given its already known outcome effects and the multimodal interventions that continue to mature with better safety profiles.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Insuficiência da Valva Mitral/complicações , Humanos , Insuficiência da Valva Mitral/cirurgia , Revascularização Miocárdica , Guias de Prática Clínica como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
14.
Eur Heart J Cardiovasc Imaging ; 25(6): 795-803, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38198413

RESUMO

AIMS: Depending on volume status, secondary tricuspid regurgitation (sTR) has a strong dynamic component. In contrast, associated structural dilatation of the tricuspid annulus and the right heart chambers may be less volume dependent. This study aimed to assess the prognostic value of right heart remodelling in isolated severe sTR (isoTR). METHODS AND RESULTS: A total of 36 000 patients from the longitudinal echocardiographic database of our tertiary centre were screened for severe isoTR [vena contracta (VC) ≥ 7 mm] in the absence of atrial fibrillation (AF), other valve disease, and/or reduced systolic left ventricular function. Echocardiographic examinations were re-read, focusing on right ventricular (RV) parameters and on quantitative and qualitative parameters of isoTR. All-cause mortality was defined as the primary endpoint. Two hundred and sixteen patients fulfilled the inclusion criteria. Severe TR was predominant; only few were classified in the new grades massive [n = 23 (10%)] and torrential TR [n = 4 (2%)]. During a median follow-up of 35 months (20-53), all-cause mortality was 31% (n = 67). Multivariate Cox regression analysis revealed no association of VC, effective regurgitant orifice area, or regurgitant volume with all-cause mortality. However, indexed RV end-diastolic diameter (P < 0.001), indexed right atrial dimensions (P = 0.019), and particularly tricuspid valve (TV) annulus diameter diastole index (P = 0.002) and TV annulus diameter systole index (P = 0.001) were significantly associated with outcome. CONCLUSION: Severe isolated TR in the absence of AF is a rare finding with a grim prognosis. Tricuspid annular diameter dimensions rather than quantitative measures of TR proved to be of significant prognostic value indicating a continuous remodelling leading to a 'point of no return' with a dismal outcome.


Assuntos
Ecocardiografia , Sistema de Registros , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide , Remodelação Ventricular , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Ecocardiografia/métodos , Prognóstico , Remodelação Ventricular/fisiologia , Estudos Retrospectivos , Medição de Risco , Valor Preditivo dos Testes , Valva Tricúspide/diagnóstico por imagem
15.
Sci Rep ; 14(1): 22067, 2024 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-39333219

RESUMO

A precise quantification of mitral regurgitation (MR) severity is essential for treatment and outcome of patients with MR. 3D echocardiography facilitates estimation of MR but selection of patients with necessity of invasive treatment remains challenging. We investigate effective regurgitation orifice area (EROA) quantification by 3D compared to 2D echocardiography in patients with MR and highlight the improved discrimination of MR severity. We consecutively enrolled fifty patients with primary or secondary and at least moderate MR undergoing 2D and 3D colour Doppler echocardiography prior to transcatheter edge-to-edge repair (TEER). Improved accuracy of MR grading using 3D vena contracta area (VCA) as an estimate of EROA was compared to 2D proximal isovelocity surface area (PISA) quantification method and a multiparameter reference standard. Quantification of EROA remarkably varies between 2D and 3D echocardiography and the discrimination between moderate and severe MR was significantly (p = 0.001) different using 2D PISA or 3D VCA, respectively. 3D VCA correlated significantly (r = 0.501, p < 0.001) better with the pre-defined MR severity. We detected crucial differences in the correct identification of severe MR between 2D and 3D techniques, thus 2D PISA significantly (p < 0.0001) underestimates EROA due to clinical and morphological parameters. The assessment of 3D VCA resulted in improved diagnostic accuracy.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Valva Mitral , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Ecocardiografia Doppler em Cores/métodos , Idoso de 80 Anos ou mais
16.
J Am Soc Echocardiogr ; 37(6): 591-598, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38522488

RESUMO

BACKGROUND: Echocardiographic grading of mitral regurgitation (MR) in mitral valve prolapse (MVP) is challenging. Three-dimensional (3D) vena contracta area (VCA) has been proposed as a valuable method. However, data defining the cutoff values of severity and validation in the subset of patients with MVP are scarce. The aim of this study was to validate the 3D VCA by 3D color-Doppler transesophageal echocardiography (TEE) in patients with MVP and to define the cutoff values of severity grading. The secondary aim was to compare 3D VCA to the effective regurgitant orifice area estimation by proximal isovelocity surface area (EROA-PISA) method. METHODS: A total of 1,138 patients with at least moderate MR who underwent TEE were included. Three-dimensional VCA was measured, and the cutoff value and area under the curve (AUC) for the prediction of severe MR were estimated by receiver operating characteristic curve using a guideline-suggested multiparametric approach as the reference standard. In a subgroup of patients, 3D regurgitant volume (RV) and 3D fraction were calculated from mitral and left ventricular outflow tract stroke volumes to further validate 3D VCA against a 3D volumetric reference standard. RESULTS: The optimal 3D VCA cutoff value for predicting severe MR was 0.45 cm2 (specificity, 0.87; sensitivity, 0.90) with an AUC of 0.95 using a multiparametric approach as reference. Three-dimensional VCA had a good linear correlation with EROA-PISA (r = 0.62, P < .05) with larger values compared to EROA-PISA (0.63 cm2 vs 0.44 cm2, P < .05). A cutoff of 0.50 cm2 (AUC of 0.84; sensitivity, 0.78; specificity, 0.78) predicts an EROA-PISA of 0.40 cm2. Three-dimensional VCA had a good linear correlation with 3D RV (r = 0.56, P < .01), with an AUC of 0.86 to predict a 3D fraction >50%. CONCLUSIONS: The present study suggests 0.45 cm2 as the best cutoff value of 3D VCA to define severe MR in patients with MVP, showing an optimal agreement with the reference standard multiparametric approach and 3D RV.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Ecocardiografia Tridimensional/métodos , Feminino , Masculino , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/fisiopatologia , Pessoa de Meia-Idade , Idoso , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Doppler em Cores/métodos , Reprodutibilidade dos Testes , Valva Mitral/diagnóstico por imagem , Curva ROC , Estudos Retrospectivos
17.
Quant Imaging Med Surg ; 14(1): 160-178, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38223056

RESUMO

Background: The 2-dimensional proximal isovelocity surface area (2D PISA) method underestimates tricuspid regurgitation (TR) severity. Previously proposed correction algorithms should be further scrutinized. Methods: Two correction algorithms were tested. One approach involves dividing the 2D PISA effective regurgitant orifice area by a constant of 0.7 (EROA0.7). Another approach involves multiplying the unadjusted EROA by Vorifice/(Vorifice - Valiasing), where Vorifice denotes the TR jet velocity, and Valiasing represents the color aliasing velocity (EROAVo-Va). In vitro validation was performed on a commercially available multifunctional valve tester with different size orifices and peak pressure gradients. A true EROA was derived through the regurgitant volume (RVol) calculated from the tester. For clinical validation, RVol was calculated as the difference between the overall stroke volume and the forward stroke volume of the right ventricle. Volumetric EROA was derived by dividing the RVol by the TR velocity-time integral (VTI). The vena contracta area (VCA) was obtained through direct planimetry with 3D echocardiography. The mean of volumetric EROA and VCA served as the reference in clinical validation. Results: Excellent correlation between the calculated EROAs and the true EROA was observed in vitro (r=0.98, r=0.97, and r=0.98 for uncorrected EROA, EROAVo-Va, and EROA0.7, respectively; all P values <0.0001). EROAVo-Va underestimated the true EROA and averaged 33% (P=0.3163), while EROA0.7 overestimated the true EROA and averaged 8% (P=0.0032). Clinically, these methods consistently exhibited a notable underestimation that varied with the reference EROA. This systematic underestimation was mitigated by both algorithms when either the VCA (biases of 19.6, 15.1, and 11.8 mm2 for uncorrected EROA, EROAVo-Va, and EROA0.7, respectively) or the volumetric EROA (biases of 10.1, 5.6, and 2.3 mm2 for uncorrected EROA, EROAVo-Va, and EROA0.7, respectively) served as the reference. Their ability to distinguish severe TR was similar, with area under the curve values of 0.905, 0.903, and 0.893 for uncorrected EROA, EROAVo-Va, and EROA0.7, respectively. No statistically significant differences were observed for diagnostic accuracy (all P values >0.05). Conclusions: Using a correction factor of 0.7 in quantifying TR provides similar accuracy when compared to other techniques. This represents a valuable clinical tool for quickly correcting the underestimation of the 2D PISA method in TR. This simple method may increase the frequency of applying the correction and earlier recognition of patients with severe TR.

19.
J Am Soc Echocardiogr ; 36(1): 77-86.e7, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36208654

RESUMO

BACKGROUND: Spatiotemporal complexity of the color Doppler vena contracta challenging the assumption of a circular and constant orifice may lead to mitral regurgitation (MR) grading inconsistencies. Using 3D transesophageal echocardiography, we characterized spatiotemporal vena contracta complexity and its impact on MR severity grading. METHODS: In 192 patients with suspected moderate or severe MR (100 primary MR [PMR]; 92 secondary MR [SMR]), we performed three-dimensional vena contracta area (VCA) quantification using single-frame (midsystolic or VCAmid, maximum or VCAmax) and multiframe (VCAmean) methods, as well as measures of orifice shape (shape index) and systolic variation of VCA. Vena contracta complexity and intermethod discrepancies were analyzed and correlated with functional class and pulmonary vein flow (PVF) patterns and with cardiac magnetic resonance (CMR) in a subset of cases (n = 20). RESULTS: The vena contracta was noncircular (shape index > 1.5) in 90% of patients. Severe noncircularity (shape index > 3) was more prevalent in SMR than in PMR (32.4% vs 14.6%). Variations of the VCA were more prominent in SMR than in PMR. VCAmid showed a low grading agreement with VCAmax (62%) and high grading agreement with VCAmean (83.3%). Pulmonary vein flow systolic reversal was associated with MR severity by VCA in SMR but not in PMR. VCAmid and VCAmean showed a stronger association with systolic flow reversal than VCAmax (area under the curve, 0.88, 0.86, and 0.79, respectively). In the subset of patients with CMR quantification, severe MR by VCAmax was graded as nonsevere by CMR more frequently compared with VCAmid and VCAmean. CONCLUSIONS: Highly prevalent spatiotemporal vena contracta complexity features in MR challenge the assumption of a circular and constant orifice. VCAmid seems the best single-frame approximation to multiframe quantification, and VCAmax may lead to severity overestimation.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana , Ecocardiografia Doppler em Cores/métodos , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa