Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(6)2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36992000

RESUMO

Wearable antenna systems have attracted significant research efforts during the last decade and a rich pool of review papers can be found in the literature. Each scientific work contributes to various fields of wearable technology focusing, mainly, on constructing materials, manufacturing techniques, targeting applications, and miniaturization methods. In this review paper, we examine the use of clothing components in wearable antenna technology. By the term "clothing components" (CC), dressmaking accessories/materials such as buttons, snap-on buttons, Velcro tapes, or zips are considered. In light of their utilization in the development of wearable antennas, the clothing components can play a triple role: (i) that of a clothing item, (ii) that of an antenna part or the main radiator, and (iii) that of an integration means of the antennas into clothes. One of their advantages is that they consist of conductive elements, integrated into the clothes, which can be effectively exploited as operating parts of wearable antennas. This review paper includes classification and description of the clothing components used so far in the development of wearable textile antennas with an emphasis on designs, applications and performance. Furthermore, a step-by-step design procedure for textile antennas that use clothing components as a functional part of their configuration is recorded, reviewed, and described in detail. The design procedure takes into account the detailed geometrical models required for the clothing components and the way they are embedded into the wearable antenna structure. In addition to the design procedure, aspects of experimental procedures (parameters, scenarios, and processes) that should be followed in wearable textile antennas with an emphasis on antennas that use clothing components (e.g., repeatability measurements) are presented. Finally, the potential of textile technology through the application of clothing components into wearable antennas is outlined.


Assuntos
Dispositivos Eletrônicos Vestíveis , Têxteis , Condutividade Elétrica
2.
Sensors (Basel) ; 23(21)2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37960644

RESUMO

The manuscript presents a novel approach to designing and fabricating a stretchable patch antenna designed for strain sensing and the wireless communication of sensing data at the same time. The challenge lies in combining flexible and stretchable textile materials with different physical morphologies, which can hinder the adhesion among multiple layers when stacked up, resisting the overall stretchability of the antenna. The proposed antenna design overcomes this challenge by incorporating a lattice hinge pattern into the non-stretchable conductive e-textile, transforming it into a stretchable structure. The innovative design includes longitudinal cuts inserted in both the patch and the ground plane of the antenna, allowing it to stretch along in the perpendicular direction. Implementing the lattice hinge pattern over the conductive layers of the proposed patch antenna, in combination with a 2 mm thick Polydimethylsiloxane (PDMS) substrate, achieves a maximum of 25% stretchability compared to its counterpart antenna without a lattice hinge design. The stretchable textile antenna resonates around a frequency of 2.45 GHz and exhibits a linear resonant frequency shift when strained up to 25%. This characteristic makes it suitable for use as a strain sensor. Additionally, the lattice hinge design enhances the conformability and flexibility of the antenna compared to that of a solid patch antenna. The realized antenna gains in the E and H-plane are measured as 2.21 dBi and 2.34 dBi, respectively. Overall, the presented design offers a simple and effective solution for fabricating a stretchable textile patch antenna for normal use or as a sensing element, opening up possibilities for applications in the communication and sensing fields.

3.
Sensors (Basel) ; 22(24)2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36559943

RESUMO

Electrical impedance tomography (EIT) is a radiation-free and noninvasive medical image reconstruction technique in which a current is injected and the reflected voltage is received through electrodes. EIT electrodes require good connection with the skin for data acquisition and image reconstruction. However, detached electrodes are a common occurrence and cause measurement errors in EIT clinical applications. To address these issues, in this study, we proposed a method for detecting faulty electrodes using the differential voltage value of the detached electrode in an EIT system. Additionally, we proposed the voltage-replace and voltage-shift methods to compensate for invalid data from the faulty electrodes. In this study, we present the simulation, experimental, and in vivo chest results of our proposed methods to verify and evaluate the feasibility of this approach.


Assuntos
Tomografia , Dispositivos Eletrônicos Vestíveis , Tomografia/métodos , Impedância Elétrica , Eletrodos , Têxteis
4.
Sensors (Basel) ; 21(20)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34696002

RESUMO

Electrical impedance tomography (EIT), a noninvasive and radiation-free medical imaging technique, has been used for continuous real-time regional lung aeration. However, adhesive electrodes could cause discomfort and increase the risk of skin injury during prolonged measurement. Additionally, the conductive gel between the electrodes and skin could evaporate in long-term usage and deteriorate the signal quality. To address these issues, in this work, textile electrodes integrated with a clothing belt are proposed to achieve EIT lung imaging along with a custom portable EIT system. The simulation and experimental results have verified the validity of the proposed portable EIT system. Furthermore, the imaging results of using the proposed textile electrodes were compared with commercial electrocardiogram electrodes to evaluate their performance.


Assuntos
Tomografia , Dispositivos Eletrônicos Vestíveis , Impedância Elétrica , Eletrodos , Têxteis
5.
Sensors (Basel) ; 21(5)2021 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-33652644

RESUMO

A textile patch antenna is an attractive package for wearable applications as it offers flexibility, less weight, easy integration into the garment and better comfort to the wearer. When it comes to wearability, above all, comfort comes ahead of the rest of the properties. The air permeability and the water vapor permeability of textiles are linked to the thermophysiological comfort of the wearer as they help to improve the breathability of textiles. This paper includes the construction of a breathable textile rectangular ring microstrip patch antenna with improved water vapor permeability. A selection of high air permeable conductive fabrics and 3-dimensional knitted spacer dielectric substrates was made to ensure better water vapor permeability of the breathable textile rectangular ring microstrip patch antenna. To further improve the water vapor permeability of the breathable textile rectangular ring microstrip patch antenna, a novel approach of inserting a large number of small-sized holes of 1 mm diameter in the conductive layers (the patch and the ground plane) of the antenna was adopted. Besides this, the insertion of a large number of small-sized holes improved the flexibility of the rectangular ring microstrip patch antenna. The result was a breathable perforated (with small-sized holes) textile rectangular ring microstrip patch antenna with the water vapor permeability as high as 5296.70 g/m2 per day, an air permeability as high as 510 mm/s, and with radiation gains being 4.2 dBi and 5.4 dBi in the E-plane and H-plane, respectively. The antenna was designed to resonate for the Industrial, Scientific and Medical band at a specific 2.45 GHz frequency.


Assuntos
Têxteis , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio , Radiação Eletromagnética , Desenho de Equipamento
6.
Sensors (Basel) ; 18(7)2018 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-29933585

RESUMO

This paper proposes a low-profile textile-modified meander line Inverted-F Antenna (IFA) with variable width and spacing meanders, for Industrial Scientific Medical (ISM) 2.4-GHz Wireless Body Area Networks (WBAN), optimized with a novel metaheuristic algorithm. Specifically, a metaheuristic known as Coral Reefs Optimization with Substrate Layer (CRO-SL) is used to obtain an optimal antenna for sensor systems, which allows covering properly and resiliently the 2.4⁻2.45-GHz industrial scientific medical bandwidth. Flexible pad foam has been used to make the designed prototype with a 1.1-mm thickness. We have used a version of the algorithm that is able to combine different searching operators within a single population of solutions. This approach is ideal to deal with hard optimization problems, such as the design of the proposed meander line IFA. During the optimization phase with the CRO-SL, the proposed antenna has been simulated using CST Microwave Studio software, linked to the CRO-SL by means of MATLAB implementation and Visual Basic Applications (VBA) code. We fully describe the antenna design process, the adaptation of the CRO-SL approach to this problem and several practical aspects of the optimization and details on the algorithm’s performance. To validate the simulation results, we have constructed and measured two prototypes of the antenna, designed with the proposed algorithm. Several practical aspects such as sensitivity during the antenna manufacturing or the agreement between the simulated and constructed antenna are also detailed in the paper.


Assuntos
Algoritmos , Desenho de Equipamento , Têxteis , Tecnologia sem Fio/instrumentação , Heurística
7.
Healthcare (Basel) ; 10(8)2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-36011209

RESUMO

This review aims to understand the different technologies incorporated into lower limbs wearable smart garments and their impact on post-exercise recovery. Electronic searches were conducted in the PubMed, Web of Science, and Cochrane electronic databases. Eligibility criteria considered meta-analyses that examined the effects of wearable smart garments on physical fitness in healthy male and female adults. Seven meta-analyses were considered in the current umbrella review, indicating small effects on delayed-onset muscle soreness ([0.40-0.43]), rate of perceived exertion (0.20), proprioception (0.49), anaerobic performance (0.27), and sprints ([0.21-0.37]). The included meta-analyses also indicated wearable smart garments have trivial to large effects on muscle strength and power ([0.14-1.63]), creatine kinase ([0.02-0.44]), lactate dehydrogenase (0.52), muscle swelling (0.73), lactate (0.98) and aerobic pathway (0.24), and endurance (0.37), aerobic performance (0.60), and running performance ([0.06-6.10]). Wearing wearable smart garments did not alter the rate of perceived exertion and had a small effect on delayed-onset muscle soreness. Well-fitting wearable smart garments improve comfort and kinesthesia and proprioception and allow a reduction in strength loss and muscle damage after training and power performance following resistance training or eccentric exercise.

8.
Materials (Basel) ; 15(8)2022 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-35454585

RESUMO

The integration of electronic components in/onto conductive textile yarns without compromising textile qualities such as flexibility, conformability, heat and moisture transfer, and wash resistance is essential to ensuring acceptance of electronic textiles. One solution is creating flexible and stretchable conductive yarns that contain tiny surface-mounted electronic elements embedded at the fiber level. The purpose of this work was to manufacture and subsequently evaluate the physical features and electromechanical properties of stainless steel yarn with light-emitting surface mounted devices (SMDs) embedded in it. The SMDs were successfully integrated into a conductive stainless steel yarn (SS) by inserting crimp beads and creating a bond through hot air soldering machines, resulting in what we call an E-yarn. The relationship curves between gauge length and electrical resistance, and the relationship curves between conductive yarn elongation and electrical resistance, were explored experimentally. The results of the analysis demonstrated that E-yarn had a lower tensile strength than the original electrically-conductive SS yarn. The effects of the washing cycle on the conductivity of the E-yarn were also investigated and studied. The results showed that E-yarns encapsulated at the solder pad by heat shrink tube still functioned well after ten machine wash cycles, after which they degraded greatly.

9.
IEEE Internet Things J ; 8(17): 13763-13773, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34722794

RESUMO

One of the major challenges faced by passive on-body wireless Internet of Things (IoT) sensors is the absorption of radiated power by tissues in the human body. We present a battery-less, wearable knitted Ultra High Frequency (UHF, 902-928 MHz) Radio Frequency Identification (RFID) compression sensor (Bellypatch) antenna and show its applicability as an on-body respiratory monitor. The antenna radiation efficiency is satisfactory in both free-space and on-body operations. We extract RF (Radio Frequency) sheet resistance values of three knitted silver-coated nylon fabric candidates at 913 MHz. The best type of fabric is selected based on the extracted RF sheet resistance. Simulated and measured performance of the antenna confirm suitability for on-body applications. The proposed Bellypatch antenna is used to measure the breathing activity of a programmable infant patient emulator mannequin (SimBaby) and a human subject. The antenna is highly sensitive to respiratory compression and relaxation. Fluctuations in the backscatter power level/Received Signal Strength Indicator (RSSI) in both cases range from 6 dB to 15 dB. The improved on-body read range of the proposed sensor antenna is 5.8 m, about 10 times higher than its predecessor wearable knitted strain sensing Bellyband antenna (0.6 m). The maximum simulated Specific Absorption Rate (SAR) on a human torso model is 0.25 W/kg, lower than the maximum allowable limit of 1.6 W/kg.

10.
Nanomaterials (Basel) ; 10(12)2020 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-33255229

RESUMO

This study demonstrates a scalable fabrication process for producing biodegradable, highly stretchable and wearable melt spun thermoplastic polypropylene (PP), poly(lactic) acid (PLA), and composite (PP:PLA = 50:50) conductive yarns through a dip coating process. Polydopamine (PDA) treated and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) coated conductive PP, PLA, and PP/PLA yarns generated electric conductivity of 0.75 S/cm, 0.36 S/cm and 0.67 S/cm respectively. Fourier Transform Infrared Spectroscopy (FTIR) confirmed the interactions among the functional groups of PP, PLA, PP/PLA, PDA, and PEDOT:PSS. The surface morphology of thermoplastic yarns was characterized by optical microscope and Scanning Electron Microscope (SEM). The mechanical properties of yarns were also assessed, which include tensile strength (TS), Young's modulus and elongation at break (%). These highly stretchable and flexible conductive PP, PLA, and PP/PLA yarns showed elasticity of 667%, 121% and 315% respectively. The thermal behavior of yarns was evaluated by differential scanning calorimetry (DSC) and thermo-gravimetric analysis (TGA). Wash stability of conductive yarns was also measured. Furthermore, ageing effect was determined to predict the shelf life of the conductive yarns. We believe that these highly stretchable and flexible PEDOT:PSS coated conductive PP, PLA, and PP/PLA composite yarns fabricated by this process can be integrated into textiles for strain sensing to monitor the tiny movement of human motion.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa