Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(3)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36772488

RESUMO

For the past several years, there has been an increasing focus on deep learning methods applied into computational pulse diagnosis. However, one factor restraining its development lies in the small wrist pulse dataset, due to privacy risks or lengthy experiments cost. In this study, for the first time, we address the challenging by presenting a novel one-dimension generative adversarial networks (GAN) for generating wrist pulse signals, which manages to learn a mapping strategy from a random noise space to the original wrist pulse data distribution automatically. Concretely, Wasserstein GAN with gradient penalty (WGAN-GP) is employed to alleviate the mode collapse problem of vanilla GANs, which could be able to further enhance the performance of the generated pulse data. We compared our proposed model performance with several typical GAN models, including vanilla GAN, deep convolutional GAN (DCGAN) and Wasserstein GAN (WGAN). To verify the feasibility of the proposed algorithm, we trained our model with a dataset of real recorded wrist pulse signals. In conducted experiments, qualitative visual inspection and several quantitative metrics, such as maximum mean deviation (MMD), sliced Wasserstein distance (SWD) and percent root mean square difference (PRD), are examined to measure performance comprehensively. Overall, WGAN-GP achieves the best performance and quantitative results show that the above three metrics can be as low as 0.2325, 0.0112 and 5.8748, respectively. The positive results support that generating wrist pulse data from a small ground truth is possible. Consequently, our proposed WGAN-GP model offers a potential innovative solution to address data scarcity challenge for researchers working with computational pulse diagnosis, which are expected to improve the performance of pulse diagnosis algorithms in the future.

2.
Sensors (Basel) ; 20(1)2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-31861412

RESUMO

During pulse signal collection, width information of pulse waves is essential for the diagnosis of disease. However, currently used measuring instruments can only detect the amplitude while can't acquire the width information. This paper proposed a novel wrist pulse signal acquisition system, which could realize simultaneous measurements of the width and amplitude of dynamic pulse waves under different static forces. A tailor-packaged micro-electro-mechanical system (MEMS) sensor array was employed to collect pulse signals, a conditioning circuit was designed to process the signals, and a customized algorithm was developed to compute the width. Experiments were carried out to validate the accuracy of the sensor array and system effectiveness. The results showed the system could acquire not only the amplitude of pulse wave but also the width of it. The system provided more information about pulse waves, which could help doctors make the diagnosis.

3.
Ir J Med Sci ; 192(6): 2697-2706, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36961673

RESUMO

BACKGROUND: The timely assessment of B-type natriuretic peptide (BNP) marking chronic heart failure risk in patients with coronary heart disease (CHD) helps to reduce patients' mortality. OBJECTIVE: To evaluate the potential of wrist pulse signals for use in the cardiac monitoring of patients with CHD. METHODS: A total of 419 patients with CHD were assigned to Group 1 (BNP < 95 pg/mL, n = 249), 2 (95 < BNP < 221 pg/mL, n = 85), and 3 (BNP > 221 pg/mL, n = 85) according to BNP levels. Wrist pulse signals were measured noninvasively. Both the time-domain method and multiscale entropy (MSE) method were used to extract pulse features. Decision tree (DT) and random forest (RF) algorithms were employed to construct models for classifying three groups, and the models' performance metrics were compared. RESULTS: The pulse features of the three groups differed significantly, suggesting different pathological states of the cardiovascular system in patients with CHD. Moreover, the RF models outperformed the DT models in performance metrics. Furthermore, the optimal RF model was that based on a dataset comprising both time-domain and MSE features, achieving accuracy, average precision, average recall, and average F1-score of 90.900%, 91.048%, 90.900%, and 90.897%, respectively. CONCLUSIONS: The wrist pulse detection technology employed in this study is useful for assessing the cardiac function of patients with CHD.


Assuntos
Doença das Coronárias , Insuficiência Cardíaca , Humanos , Punho , Peptídeo Natriurético Encefálico , Insuficiência Cardíaca/diagnóstico , Doença das Coronárias/complicações , Frequência Cardíaca , Biomarcadores
4.
Health Inf Sci Syst ; 10(1): 7, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35529250

RESUMO

Purpose: Vascular age (VA) is the direct index to reflect vascular aging, so it plays a particular role in public health. How to obtain VA conveniently and cheaply has always been a research hotspot. This study proposes a new method to evaluate VA with wrist pulse signal. Methods: Firstly, we fit the pulse signal by mixed Gaussian model (MGM) to extract the shape features, and adopt principal component analysis (PCA) to optimize the dimension of the shape features. Secondly, the principal components and chronological age (CA) are respectively taken as the independent variables and dependent variable to establish support vector regression (SVR) model. Thirdly, the principal components are fed into the SVR model to predicted the vascular aging of each subject. The predicted value is regarded as the description of VA. Finally, we compare the correlation coefficients of VA with pulse width (PW), inflection point area ratio (IPA), Ratio b/a (RBA), augmentation index (AIx), diastolic augmentation index (DAI) and pulse transit time (PTT) with those of CA with these six indices. Results: Compared with the CA, the VA is closer to PW (r = 0.539, P < 0.001 to r = 0.589, P < 0.001 in men; r = 0.325, P < 0.001 to r = 0.400, P < 0.001 in women), IPA (r = - 0.446, P < 0.001 to r = - 0.534, P < 0.001 in men; r = - 0.623, P < 0.001 to r = - 0.660, P < 0.001 in women), RBA (r = 0.328, P < 0.001 to r = 0.371, P < 0.001 in women), AIx (r = 0.659, P < 0.001 to r = 0.738, P < 0.001 in men; r = 0.547, P < 0.001 to r = 0.573, P < 0.001 in women), DAI (r = 0.517, P < 0.001 to r = 0.532, P < 0.001 in men; r = 0.507, P < 0.001 to r = 0.570, P < 0.001 in women) and PTT (r = 0.526, P < 0.001 to r = 0.659, P < 0.001 in men; r = 0.577, P < 0.001 to r = 0.814, P < 0.001 in women). Conclusion: The VA is more representative of vascular aging than CA. The method presented in this study provides a new way to directly and objectively assess vascular aging in public health.

5.
Biosensors (Basel) ; 12(2)2022 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-35200393

RESUMO

Continuous monitoring of pulse waves plays a significant role in reflecting physical conditions and disease diagnosis. However, the current collection equipment cannot simultaneously achieve wearable and continuous monitoring under varying pressure and provide personalized pulse wave monitoring targeted different human bodies. To solve the above problems, this paper proposed a novel wearable and real-time pulse wave monitoring system based on a novel flexible compound sensor. Firstly, a custom-packaged pressure sensor, a signal stabilization structure, and a micro pressurization system make up the flexible compound sensor to complete the stable acquisition of pulse wave signals under continuously varying pressure. Secondly, a real-time algorithm completes the analysis of the trend of the pulse wave peak, which can quickly and accurately locate the best pulse wave for different individuals. Finally, the experimental results show that the wearable system can both realize continuous monitoring and reflecting trend differences and quickly locate the best pulse wave for different individuals with the 95% accuracy. The weight of the whole system is only 52.775 g, the working current is 46 mA, and the power consumption is 160 mW. Its small size and low power consumption meet wearable and portable scenarios, which has significant research value and commercialization prospects.


Assuntos
Dispositivos Eletrônicos Vestíveis , Algoritmos , Frequência Cardíaca/fisiologia , Humanos , Monitorização Fisiológica/métodos , Pulso Arterial
6.
Biomed Mater Eng ; 29(1): 53-65, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29254073

RESUMO

BACKGROUND: WPS is a non-invasive method to investigate human health. During signal acquisition, noises are also recorded along with WPS. OBJECTIVE: Clean WPS with high peak signal to noise ratio is a prerequisite before use in disease diagnosis. Wavelet Transform is a commonly used method in the filtration process. Apart from its extensive use, the appropriate factors for wavelet denoising algorithm is not yet clear in WPS application. The presented work gives an effective approach to select various factors for wavelet denoise algorithm. With the appropriate selection of wavelet and factors, it is possible to reduce noise in WPS. METHODS: In this work, all the factors of wavelet denoising are varied successively. Various evaluation parameters such as MSE, PSNR, PRD and Fit Coefficient are used to find out the performance of the wavelet denoised algorithm at every one step. RESULTS: The results obtained from computerized WPS illustrates that the presented approach can successfully select the mother wavelet and other factors for wavelet denoise algorithm. The selection of db9 as mother wavelet with sure threshold function and single rescaling function using UWT has been a better option for our database. CONCLUSION: The empirical results proves that the methodology discussed here could be effective in denoising WPS of any morphological pattern.


Assuntos
Algoritmos , Frequência Cardíaca , Análise de Ondaletas , Punho/fisiologia , Desenho de Equipamento , Humanos , Processamento de Sinais Assistido por Computador/instrumentação , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa