Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.204
Filtrar
Mais filtros

Eixos temáticos
Intervalo de ano de publicação
1.
Gut ; 73(4): 629-638, 2024 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-38195219

RESUMO

OBJECTIVE: Elevated pancreatic cyst fluid carcinoembryonic antigen (CEA) has been routinely used to classify mucinous cysts. This study incorporates original data that established the CEA ≥192 ng/mL threshold with over 20 years of additional data and reassesses the diagnostic performance of CEA for differentiating mucinous from non-mucinous cysts. DESIGN: 1169 pancreatic cysts (1999-2021) with CEA results were identified. 394 cases had histological confirmation as the diagnostic standard. Additionally, 237 cysts without histological confirmation demonstrated KRAS, GNAS, or RNF43 mutations by molecular testing and were combined with the histologically confirmed cysts for separate analysis on a total cohort of 631 cysts. RESULTS: Median CEA was significantly higher in mucinous cysts (323.9 ng/mL, n=314) versus non-mucinous cysts (204.6 ng/mL, n=80) (p<0.001). Receiver operating characteristic curve analysis demonstrated an optimal CEA cut-off of 20 ng/mL (area under the curve: 80%), though the specificity was lower than desired (sensitivity 89%, specificity 64%). At the previously established threshold of 192 ng/mL, sensitivity and specificity were 56% and 78%, respectively. To achieve a specificity of 85% as originally reported, a CEA threshold of 250 ng/mL was needed; the 13 false positive cases at this threshold included 4 benign simple cysts, 2 squamoid cysts, 1 serous cystadenoma, 1 lymphoepithelial cyst and 5 more uncommon entities. All results remained similar within the total cohort after including additional cases with KRAS/GNAS/RNF43 mutations only. CONCLUSION: Cyst fluid CEA continues to be a useful test in the diagnosis of mucinous pancreatic cysts but does not appear as specific as previously reported. Raising the CEA threshold to 250 ng/mL to maintain specificity for differentiating mucinous from non-mucinous cysts may be considered.


Assuntos
Cisto Pancreático , Neoplasias Pancreáticas , Humanos , Antígeno Carcinoembrionário/análise , Líquido Cístico/química , Proteínas Proto-Oncogênicas p21(ras)/genética , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/patologia , Estudos Retrospectivos , Cisto Pancreático/diagnóstico , Cisto Pancreático/genética , Cisto Pancreático/patologia
2.
Anal Chem ; 96(21): 8365-8372, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38717986

RESUMO

Simultaneous sensitive and precise determination of multibiomarkers is of great significance for improving detection efficiency, reducing diagnosis and treatment expenses, and elevating survival rates. However, the development of simple and portable biosensors for simultaneous determination of multiplexed targets in biological fluids still faces challenges. Herein, a unique and versatile immobilization-free dual-target electrochemical biosensing platform, which combines distinguishable magnetic signal reporters with buoyancy-magnetism separation, was designed and constructed for simultaneous detection of carcinoembryonic (CEA) and α-fetoprotein (AFP) in intricate biological fluids. To construct such distinguishable magnetic signal reporters with signal transduction, amplification, and output, secondary antibodies of CEA and AFP were respectively functionalized on methylene blue (MB) and 6-(ferrocenyl)hexanethiol (FeC) modified Fe3O4@Au magnetic nanocomposites. Meanwhile, a multifunctional flotation probe with dual target recognition, capture, and isolation capability was prepared by conjugating primary antibodies (Ab1-CEA, Ab1-AFP) to hollow buoyant microspheres. The target antigens of CEA and AFP can trigger a flotation-mediated sandwich-type immunoreaction and capture a certain amount of the distinguishable magnetic signal reporter, which enables the conversion of the target CEA and AFP quantities to the signal of the potential-resolved MB and FeC. Thus, the MB and FeC currents of magnetically adsorbed distinguishable magnetic reporters can be used to determine the CEA and AFP targets simultaneously and precisely. Accordingly, the proposed strategy exhibited a delightful linear response for CEA and AFP in the range of 100 fg·mL-1-100 ng·mL-1 with detection limits of 33.34 and 17.02 fg·mL-1 (S/N = 3), respectively. Meanwhile, no significant nonspecific adsorption and cross-talk were observed. The biosensing platform has shown satisfactory performance in the determination of real clinical samples. More importantly, the proposed approach can be conveniently extended to universal detection just by simply substituting biorecognition events. Thus, this work opens up a new promising perspective for dual and even multiple targets and offers promising potential applications in clinical diagnosis.


Assuntos
Técnicas Biossensoriais , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , alfa-Fetoproteínas , alfa-Fetoproteínas/análise , alfa-Fetoproteínas/imunologia , Antígeno Carcinoembrionário/análise , Antígeno Carcinoembrionário/imunologia , Técnicas Biossensoriais/métodos , Humanos , Imunoensaio/métodos , Ouro/química , Limite de Detecção
3.
Anal Chem ; 96(21): 8740-8746, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38722256

RESUMO

Pressure and temperature, as common physical parameters, are important for monitoring human health. In contrast, single-mode monitoring is prone to causing experimental errors. Herein, we innovatively designed a dual-mode flexible sensing platform based on a platinum/zinc-meso-tetrakis(4-carboxyphenyl)porphyrin (Pt/Zn-TCPP) nanozyme for the quantitative monitoring of carcinoembryonic antigen (CEA) in biological fluids with pressure and temperature readouts. The Pt/Zn-TCPP nanozyme with catalytic and photothermal efficiencies was synthesized by means of integrating photosensitizers into porous materials. The flexible sensing system after the antigen-antibody reaction recognized the pressure using a flexible skin-like pressure sensor with a digital multimeter readout, whereas the temperature was acquired via the photoheat conversion system of the Pt/Zn-TCPP nanozyme under 808 nm near-infrared (NIR) irradiation using a portable NIR imaging camera on a smartphone. Meanwhile, the dual-mode flexible sensing system was carried out on a homemade three-dimensional (3D)-printed device. Results revealed that the developed dual-mode immunosensing platform could exhibit good pressure and temperature responses within the dynamic range of 0.5-100 ng mL-1 CEA with the detection limits of 0.24 and 0.13 ng mL-1, respectively. In addition, the pressure and temperature were sensed simultaneously without crosstalk interference. Importantly, the dual-mode flexible immunosensing system can effectively avoid false alarms during the measurement, thus providing great potential for simple and low-cost development for point-of-care testing.


Assuntos
Antígeno Carcinoembrionário , Platina , Pressão , Temperatura , Zinco , Platina/química , Imunoensaio/métodos , Zinco/química , Antígeno Carcinoembrionário/análise , Humanos , Porfirinas/química , Nanoestruturas/química , Limite de Detecção
4.
Anal Chem ; 96(36): 14372-14381, 2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39190788

RESUMO

In this work, SiO2/CNTs photonic crystal beads were constructed by doping CNTs into SiO2 photonic crystals, which have an angle-independent responsive structural color and can be used as bipolar electrodes due to their good electrical conductivity. In addition, the bipolar electrode-electrochemiluminescence (BPE-ECL) experiments and finite element simulation prove that the low driving voltage can trigger the bipolar electrode electrochemical reactions by confinement effect. Inspired by this, it is the first to combine the SiO2/CNTs structural color coding scheme with low-drive voltage induced wireless BPE-ECL imaging based on the confinement effect of microchannels to achieve simultaneous immune detection of ovarian cancer biomarkers (CA125, CEA, AFP). The detection limits of successfully constructed high-throughput BPE-ECL biosensor for AFP, CEA, and CA125 are 0.72 ng/mL, 0.95 ng/mL, and 1.03 U/mL, respectively, and have good stability and specificity, which expands the application of electrochemiluminescence and lays a foundation for the development of electrochemiluminescence coding technology.


Assuntos
Antígeno Ca-125 , Técnicas Eletroquímicas , Medições Luminescentes , Humanos , Antígeno Ca-125/análise , Técnicas Biossensoriais , Antígeno Carcinoembrionário/análise , Dióxido de Silício/química , Biomarcadores Tumorais/análise , Tecnologia sem Fio , Neoplasias Ovarianas/diagnóstico por imagem , alfa-Fetoproteínas/análise , Feminino , Cor , Eletrodos , Limite de Detecção
5.
Anal Chem ; 96(21): 8837-8843, 2024 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-38757510

RESUMO

Breast cancer poses the significance of early diagnosis and treatment. Here, we developed an innovative photoelectrochemical (PEC) immunosensor characterized by high-level dual photocurrent signals and exceptional sensitivity. The PEC sensor, denoted as MIL&Ag2S, was constructed by incorporating Ag2S into a metal-organic framework of MIL-101(Cr). This composite not only enhanced electron-hole separation and conductivity but also yielded robust and stable dual photocurrent signals. Through the implementation of signal switching, we achieved the combined detection of cancer antigen 15-3 (CA15-3) and carcinoembryonic antigen (CEA) with outstanding stability, reproducibility, and specificity. The results revealed a linear range for CEA detection spanning 0.01-32 ng/mL, with a remarkably low detection limit of 0.0023 ng/mL. Similarly, for CA15-3 detection, the linear range extended from 0.1 to 320 U/mL, with a low detection limit of 0.014 U/mL. The proposed strategy introduces new avenues for the development of highly efficient, cost-effective, and user-friendly PEC sensors. Furthermore, it holds promising prospects for early clinical diagnosis, contributing to potential breakthroughs in medical detection and ultimately improving patient outcomes.


Assuntos
Biomarcadores Tumorais , Neoplasias da Mama , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , Estruturas Metalorgânicas , Mucina-1 , Compostos de Prata , Estruturas Metalorgânicas/química , Humanos , Neoplasias da Mama/diagnóstico , Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/análise , Mucina-1/análise , Mucina-1/sangue , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/análise , Compostos de Prata/química , Imunoensaio/métodos , Técnicas Biossensoriais , Feminino , Limite de Detecção , Processos Fotoquímicos , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química
6.
Anal Chem ; 96(33): 13690-13698, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39108033

RESUMO

BRCA1 gene and carcinoembryonic antigen (CEA) are important markers of breast cancer, so accurate detection of them is significant for early detection and diagnosis of breast cancer. In this study, a potential-resolved ratio electrochemiluminescence (ECL) biosensor using perylene diimide (PDI)-metal-organic framework and DNA nanoflowers (NFs)-CdS quantum dots (QDs) was constructed for detection of BRCA1 and CEA. Specifically, PDI-MOF and CdS QDs can generate potential-resolved intense ECL signals only using one coreactant, so the detection procedure can be effectively simplified. PDI-MOF was first attached to the electrode by graphene oxide, and the dopamine (DA) probe was linked to quench the ECL signal by DNA hybridization. In the presence of target BRCA1, it can form a bipedal DNA walker, so the quenching molecules (DA) were detached from the electrode via the walker amplification process aided by Mg2+, so that the PDI signal at -0.25 V was restored for the BRCA1 assay. Moreover, CdS QDs@DNA NFs as amplified signal probes were formed by self-assembly, and the target CEA-amplified product introduced the CdS QDs@DNA NFs to the electrode, so the QD ECL signal at -1.42 V was enhanced, while the ECL signal of PDI is unchanged; thus, CEA detection was achieved by the ratio value between them. Therefore, the detection accuracy is guaranteed by detection of two cancer markers and a ratio value. This biosensor has a great contribution to the development of new ECL materials and a novel ECL technique for fast and efficient multitarget assays, showing great significance for the early monitoring and diagnosis of breast cancer.


Assuntos
Proteína BRCA1 , Técnicas Biossensoriais , Compostos de Cádmio , Antígeno Carcinoembrionário , DNA , Técnicas Eletroquímicas , Imidas , Medições Luminescentes , Perileno , Pontos Quânticos , Sulfetos , Perileno/química , Perileno/análogos & derivados , Pontos Quânticos/química , Compostos de Cádmio/química , Técnicas Biossensoriais/métodos , Sulfetos/química , Técnicas Eletroquímicas/métodos , Imidas/química , DNA/química , Humanos , Proteína BRCA1/genética , Proteína BRCA1/análise , Antígeno Carcinoembrionário/análise , Antígeno Carcinoembrionário/sangue , Estruturas Metalorgânicas/química
7.
Opt Express ; 32(11): 20024-20034, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38859121

RESUMO

An optical fiber sensing probe using a composite sensitive film of polyacrylonitrile (PAN) nanofiber membrane and gold nanomembrane is presented for the detection of a carcinoembryonic antigen (CEA), a biomarker associated with colorectal cancer and other diseases. The probe is based on a tilted fiber Bragg grating (TFBG) with a surface plasmon resonance (SPR) gold nanomembrane and a functionalized polyacrylonitrile (PAN) PAN nanofiber coating that selectively binds to CEA molecules. The performance of the probe is evaluated by measuring the spectral shift of the TFBG resonances as a function of CEA concentration in buffer. The probe exhibits a sensitivity of 0.46 dB/(µg/ml), a low limit of detection of 505.4 ng/mL in buffer, and a good selectivity and reproducibility. The proposed probe offers a simple, cost-effective, and a novel method for CEA detection that can be potentially applied for clinical diagnosis and monitoring of CEA-related diseases.


Assuntos
Resinas Acrílicas , Antígeno Carcinoembrionário , Ouro , Nanofibras , Fibras Ópticas , Ressonância de Plasmônio de Superfície , Antígeno Carcinoembrionário/análise , Ouro/química , Nanofibras/química , Ressonância de Plasmônio de Superfície/instrumentação , Ressonância de Plasmônio de Superfície/métodos , Resinas Acrílicas/química , Humanos , Técnicas Biossensoriais/instrumentação , Membranas Artificiais , Nanopartículas Metálicas/química , Reprodutibilidade dos Testes , Tecnologia de Fibra Óptica/instrumentação
8.
Analyst ; 149(19): 4908-4914, 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39119745

RESUMO

While it is recognized that early diagnosis of cancer-related biomarkers can become an effective avenue for timely treatment and successfully improve patient survival, it remains challenging to get accurate inspection results. Currently, most reported cancer biomarker sensing methods are focused on the quantitative detection of a single type of biomarker, which makes accurate medical diagnostics difficult. In this work, we constructed a DNA walker nanomachine aptasensor based on gold nanoparticles for the simultaneous sensing of dual cancer biomarkers. The aptamers, labelled with a fluorophore, hybridized with complementary strands on the gold nanoparticle surface, serve as a walking track. Target analytes bind to their specific aptamers, leading to the dissociation of the unstable double-strand spherical nucleic acid. Exonuclease I (Exo I) selectively digested the aptamers bound with the target analytes, then the released targets go back to the next apamers on the gold nanopareticles surface for walking. The use of spherical nucleic acid probes improved the sensitivity of analyte detection. Exo I provided a driving power for target recycling and considerably improved the sensitivity of the aptasensor as well. The DNA walker nanomachine aptasensor was successfully applied for the detection of carcinoembryonic antigen (CEA) in the range of 0.167 to 3.34 ng mL-1, and mucin-1 (MUC-1) in the same range. Moreover, we used the two aptamers to construct the DNA walker nanomachine and achieved the simultaneous detection of CEA and MUC-1, thus having great potential for biomolecular logic gate construction and early disease diagnosis.


Assuntos
Aptâmeros de Nucleotídeos , Biomarcadores Tumorais , Técnicas Biossensoriais , Antígeno Carcinoembrionário , Ouro , Nanopartículas Metálicas , Mucina-1 , Aptâmeros de Nucleotídeos/química , Humanos , Ouro/química , Biomarcadores Tumorais/análise , Nanopartículas Metálicas/química , Mucina-1/análise , Técnicas Biossensoriais/métodos , Antígeno Carcinoembrionário/análise , Antígeno Carcinoembrionário/sangue , Limite de Detecção , Exodesoxirribonucleases/química , Exodesoxirribonucleases/metabolismo , DNA/química , Hibridização de Ácido Nucleico
9.
Anal Bioanal Chem ; 416(21): 4789-4805, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38878180

RESUMO

Organic-inorganic hybrid nanocomposites (OIHN), with tailored surface chemistry, offer ultra-sensitive architecture capable of detecting ultra-low concentrations of target analytes with precision. In the present work, a novel nano-biosensor was fabricated, acquainting dynamic synergy of reduced graphene oxide (rGO) decorated hexagonal boron nitride nanosheets (hBNNS) for detection of carcinoembryonic antigen (CEA). Extensive spectroscopic and microscopic analyses confirmed the successful hydrothermal synthesis of cross-linked rGO-hBNNS nanocomposite. Uniform micro-electrodes of rGO-hBNNS onto pre-hydrolyzed ITO were obtained via electrophoretic deposition (EPD) technique at low DC potential (15 V). Optimization of antibody incubation time, pH of supporting electrolyte, and immunoelectrode preparation was thoroughly investigated to enhance nano-biosensing efficacy. rGO-modified hBNNS demonstrated 29% boost in electrochemical performance over bare hBNNS, signifying remarkable electro-catalytic activity of nano-biosensor. The presence of multifunctional groups on the interface facilitated stable crosslinking chemistry, increased immobilization density, and enabled site-specific anchoring of Anti-CEA, resulting in improved binding affinity. The nano-biosensor demonstrated a remarkably low limit of detection of 5.47 pg/mL (R2 = 0.99963), indicating exceptional sensitivity and accuracy in detecting CEA concentrations from 0 to 50 ng/mL. The clinical evaluation confirmed its exceptional shelf life, minimal cross-reactivity, and robust recovery rates in human serum samples, thereby unraveling the potential for early, highly sensitive, and reliable CEA detection.


Assuntos
Técnicas Biossensoriais , Compostos de Boro , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , Grafite , Limite de Detecção , Nanocompostos , Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/análise , Grafite/química , Nanocompostos/química , Técnicas Eletroquímicas/métodos , Humanos , Técnicas Biossensoriais/métodos , Compostos de Boro/química , Catálise , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia
10.
Luminescence ; 39(9): e4899, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39285582

RESUMO

The sensitive detection of cancer biomarkers is crucial for early accurate diagnostics and therapy of cancer patients. Carcinoembryonic antigen (CEA) is a tumor-associated antigen derived from colon cancer and embryonic tissues. In this study, we have developed a label-free fluorescence biosensing platform for the quantification of CEA with the "turn-on" signal output. This platform employs a label-free strategy that incorporates an aptamer-modified gold nanoparticle (Apt@AuNP) probe for the recognition of CEA, in combination with hybridization chain reaction (HCR) amplification. In the presence of target CEA, Apt@AuNPs selectively capture CEA, resulting in a reduction of subsequent complementary chains (CP) binding on Apt@AuNPs. The remaining CP, acting as the initiator sequence for HCR, triggers the HCR, leading to the formation of abundant G-quadruplex structures. By employing Thioflavin T (ThT) for the formation of G-quadruplex/ThT complexes, the biosensor exhibits a significant enhancement of the fluorescence signal. Under optimized conditions, the biosensor platform demonstrates a limit of detection of 0.03 nM and a linear range from 0.1 to 2.5 nM. Additionally, the specificity investigation reveals the high selectivity of this fluorescent biosensor. Finally, the performance of this method has been validated by successfully detecting CEA in real-life samples, highlighting its potential for clinical applications.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Antígeno Carcinoembrionário , Ouro , Nanopartículas Metálicas , Hibridização de Ácido Nucleico , Ouro/química , Antígeno Carcinoembrionário/análise , Aptâmeros de Nucleotídeos/química , Nanopartículas Metálicas/química , Humanos , Espectrometria de Fluorescência , Limite de Detecção , Fluorescência
11.
Mikrochim Acta ; 191(9): 555, 2024 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-39172272

RESUMO

A novel signal amplification strategy was developed by combining near-infrared light with MoS2/CuO/Au nanocomposite for building a colorimetric immunoassay. First, MoS2/CuO/Au nanocomposite was synthesized by precipitation and photoreduction methods and characterized by scanning electron microscopy (SEM) and X-ray powder diffraction (XRD). MoS2/CuO/Au nanocomposite has oxidase-like activity and can oxidize TMB to form a blue product (TMBox). Further, the catalytic oxidation of TMB was accelerated under near-infrared (NIR) laser radiation. The sandwich-type colorimetric immunoassay was constructed using MoS2/CuO/Au nanocomposite. Under the enhancement of near-infrared light, carcinoembryonic antigen (CEA) was sensitively detected in the range 0.1 to 40 ng/mL with the limit of detection of 0.03 ng/mL. Moreover, the immunosensor has excellent selectivity and anti-interference, good repeatability, and stability.


Assuntos
Biomarcadores Tumorais , Antígeno Carcinoembrionário , Colorimetria , Cobre , Dissulfetos , Ouro , Raios Infravermelhos , Limite de Detecção , Molibdênio , Nanocompostos , Molibdênio/química , Nanocompostos/química , Cobre/química , Dissulfetos/química , Colorimetria/métodos , Ouro/química , Humanos , Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/análise , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/análise , Imunoensaio/métodos , Técnicas Biossensoriais/métodos , Anticorpos Imobilizados/imunologia
12.
Mikrochim Acta ; 191(7): 407, 2024 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898338

RESUMO

A smartphone-based electrochemical aptasensing platform was developed for the point-of-care testing (POCT) of carcinoembryonic antigen (CEA) based on the ferrocene (Fc) and PdPt@PCN-224 dual-signal labeled strategy. The prepared PdPt@PCN-224 nanocomposite showed a strong catalytic property for the reduction of H2O2. Phosphate group-labeled aptamer could capture PdPt@PCN-224 by Zr-O-P bonds to form PdPt@PCN-224-P-Apt. Therefore, a dual signal labeled probe was formed by the hybridization between Fc-DNA and PdPt@PCN-224-P-Apt. The presence of CEA forced PdPt@PCN-224-P-Apt to leave the electrode surface due to the specific affinity, leading to the decrease of the reduction current of H2O2. At the same time, the Fc-DNA strand changed to hairpin structure, which made Fc closer to the electrode and resulted in the increase of the oxidation current of Fc. Thus, CEA can be accurately determined through both signals: the decrease of H2O2 reduction current and the increase of Fc oxidation current, which could avoid the false positive signal. Under the optimal conditions, the prepared aptasensor exhibited a wide linear range from 1 pg·mL-1 to 100 ng·mL-1 and low detection limits of 0.98 pg·mL-1 and 0.27 pg·mL-1 with Fc and PdPt@PCN-224 as signal labels, respectively. The aptasensor developed in this study has successfully demonstrated its capability to detect CEA in real human serum samples. These findings suggest that the proposed sensing platform will hold great potential for clinical tumor diagnosis and monitoring.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , Compostos Ferrosos , Peróxido de Hidrogênio , Limite de Detecção , Paládio , Testes Imediatos , Smartphone , Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/análise , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Humanos , Técnicas Biossensoriais/métodos , Peróxido de Hidrogênio/química , Paládio/química , Compostos Ferrosos/química , Metalocenos/química , Platina/química
13.
Mikrochim Acta ; 191(9): 549, 2024 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-39162737

RESUMO

An intense cathodic electrochemiluminescence (ECL) is reported from a polarized glassy carbon electrode (GCE) in peroxydisulfate solution. After the polarization in 1 M Na2SO4 at the potential of - 3.7 V for 3 s, carbon nanosheets (C-NSs) were in situ grown on the surface of the GCE. Measured in 100 mM K2S2O8 solution, the ECL intensity of the GCE/C-NSs is 112-fold that of a bare GCE. The ECL spectrum revealed that the true ECL luminophore in the GCE/C-NSs-peroxydisulfate system is O2/S2O82- which is promoted by C-NSs. When Cu2+ was electrochemically enriched and reduced to Cu(0) on the catalytic sites of C-NSs, the ECL from GCE/C-NSs/Cu in K2S2O8 solution was decreased with increasing logarithmic concentration of Cu2+ in the range from 10 pM to 1 µM, with a limit of detection (LOD) of 3 pM. An immunoanalysis method is proposed via a biometallization strategy using CuS nanoparticles as the tags and carcinoembryonic antigen (CEA) as the model analyte. After the immune recognition in the microplate, the CuS tags in the immunocomplex were dissolved and the resultant Cu2+ was electrochemically enriched and reduced on the catalytic sites of C-NSs, quenching the ECL intensity of GCE/C-NSs-O2/S2O82- system. The proposed ECL immunoanalysis method was used to quantify CEA in actual serum samples with an LOD of 1.0 fg mL-1, possessing the advantages of simple electrode modification, high sensitivity and good reproducibility.


Assuntos
Carbono , Antígeno Carcinoembrionário , Cobre , Técnicas Eletroquímicas , Eletrodos , Medições Luminescentes , Carbono/química , Medições Luminescentes/métodos , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/imunologia , Antígeno Carcinoembrionário/análise , Cobre/química , Limite de Detecção , Humanos , Nanoestruturas/química , Imunoensaio/métodos , Sulfato de Cobre/química , Nanopartículas Metálicas/química , Vidro/química , Sulfatos/química
14.
Molecules ; 29(13)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38999110

RESUMO

Electrochemical biosensors have emerged as powerful tools for the ultrasensitive detection of lung cancer biomarkers like carcinoembryonic antigen (CEA), neuron-specific enolase (NSE), and alpha fetoprotein (AFP). This review comprehensively discusses the progress and potential of nanocomposite-based electrochemical biosensors for early lung cancer diagnosis and prognosis. By integrating nanomaterials like graphene, metal nanoparticles, and conducting polymers, these sensors have achieved clinically relevant detection limits in the fg/mL to pg/mL range. We highlight the key role of nanomaterial functionalization in enhancing sensitivity, specificity, and antifouling properties. This review also examines challenges related to reproducibility and clinical translation, emphasizing the need for standardization of fabrication protocols and robust validation studies. With the rapid growth in understanding lung cancer biomarkers and innovations in sensor design, nanocomposite electrochemical biosensors hold immense potential for point-of-care lung cancer screening and personalized therapy guidance. Realizing this goal will require strategic collaboration among material scientists, engineers, and clinicians to address technical and practical hurdles. Overall, this work provides valuable insight for developing next-generation smart diagnostic devices to combat the high mortality of lung cancer.


Assuntos
Biomarcadores Tumorais , Técnicas Biossensoriais , Técnicas Eletroquímicas , Neoplasias Pulmonares , Humanos , Biomarcadores Tumorais/análise , Neoplasias Pulmonares/diagnóstico , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Antígeno Carcinoembrionário/análise , Antígeno Carcinoembrionário/sangue , Nanocompostos/química , Grafite/química
15.
Dermatol Online J ; 30(2)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38959917

RESUMO

Squamoid eccrine ductal carcinoma (SEDC) is a cutaneous adnexal malignancy that is histologically challenging to distinguish from squamous cell carcinoma. We report three cases of this rare entity and review the present literature regarding clinical, histological, and immunohistochemical features. Patients presented with a single nodule or plaque lesion on their back and temple. The shave biopsies for Patient A and C were interpreted as SEDC. Patient B's initial shave biopsy was interpreted as probable surface of squamous cell carcinoma, and subsequent excision revealed SEDC. Ductal differentiation was confirmed by positive expression of epithelial membrane antigen and carcinoembryonic antigen immunostains in all three patients. Review of the 67 previously reported cases emphasizes the importance of diagnosing SEDC accurately and promptly given its potential for distant metastasis and mortality. Perineural or lymphatic invasion is associated with higher rate of recurrence or metastasis. There should be high pathologic suspicion for SEDC in an elderly patient presenting with a palpable lesion, even if located outside of the head and neck area, particularly when there is suggestion of ductal differentiation in a sample of a squamous neoplasm.


Assuntos
Carcinoma de Células Escamosas , Glândulas Écrinas , Neoplasias das Glândulas Sudoríparas , Humanos , Antígeno Carcinoembrionário/análise , Antígeno Carcinoembrionário/metabolismo , Carcinoma Ductal/patologia , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/diagnóstico , Diagnóstico Diferencial , Glândulas Écrinas/patologia , Imuno-Histoquímica , Mucina-1/análise , Mucina-1/metabolismo , Neoplasias Cutâneas/patologia , Neoplasias Cutâneas/diagnóstico , Neoplasias das Glândulas Sudoríparas/patologia , Idoso
16.
Anal Chem ; 95(44): 16335-16342, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37878838

RESUMO

Cation exchange (CE) is a burgeoning method for controlled crystal synthesis; however, its applications in bioanalysis are still in their infancy. Herein, we explored the transformation of ZnIn2S4 in properties after the CE reaction with Cu2+ ions; furthermore, the discrepancy was employed to design a dual-readout detection system of photothermal and polarity-switchable photoelectrochemical (PEC) immunoassays to realize reliable detection of carcinoembryonic antigen (CEA). In the presence of CEA, the CuO nanoparticles (CuO NPs) employed as dual-signal response probes would bond to the microplates and be acidolyzed by HCl to release Cu2+, which could replace Zn2+ and In3+ via the CE reaction. After the CE reaction is completed, the photocurrent would switch from a weak anodic photocurrent to a cathode one by using a 635 nm laser as a signal amplifier, while the photothermal signal would be enhanced with 808 nm laser illumination. On the basis of the polarity-switchable PEC strategy, CEA could be accurately detected from 0.1 to 50 ng mL-1 with a limit of detection (LOD) of 48 pg mL-1 (S/N = 3). Moreover, the photothermal assay for CEA detection possesses a linear range from 0.5 to 100 ng mL-1 with a LOD of 0.21 ng mL-1. In addition, the designed sensing platform only relies on devices with portability that are permitted for point-of-care detection.


Assuntos
Técnicas Biossensoriais , Antígeno Carcinoembrionário , Antígeno Carcinoembrionário/análise , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Limite de Detecção , Cátions
17.
Anal Chem ; 95(18): 7109-7117, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-37098252

RESUMO

In this paper, a novel donor-acceptor pair was creatively proposed based on the principle of electrochemiluminescence resonance energy transfer (ECL-RET): luminol immobilized on polyethyleneimine (PEI)-functionalized manganese-based single-atom nanozymes (Mn SANE/PEI-luminol, donor) and a PtCu-grafted hollow metal polydopamine framework (PtCu/h-MPF, acceptor). A quenched ECL immunosensor was constructed for the ultrasensitive analysis of carcinoembryonic antigen (CEA). Mn SANE, as an efficient novel coreaction accelerator with the outstanding performance of significantly activating H2O2 to produce large amounts of ROS, was further modified by the coreactant PEI, which efficiently immobilized luminol to form a self-enhanced emitter. As a result, the electron transport distance was effectively shortened, the energy loss was reduced, and luminol achieved a high ECL efficiency. More importantly, PtCu-grafted h-MPF (PtCu/h-MPF) was proposed as a novel quencher. The UV-vis spectra of PtCu/h-MPF partially overlap with the ECL spectra of Mn SANE/PEI-luminol, which can effectively trigger the ECL-RET behavior between the donor and the acceptor. The multiple quenching effect on Mn SANE/PEI-luminol was achieved, which significantly improved the sensitivity of the immunosensor. The prepared immunosensor exhibited good linearity in the concentration range of 10-5 to 80 ng/mL. The results indicate that this work provides a new method for the early detection of CEA in clinical diagnosis.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Luminol , Antígeno Carcinoembrionário/análise , Polietilenoimina , Técnicas Biossensoriais/métodos , Peróxido de Hidrogênio , Técnicas Eletroquímicas/métodos , Medições Luminescentes/métodos , Imunoensaio/métodos , Limite de Detecção
18.
Anal Biochem ; 683: 115370, 2023 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-37890548

RESUMO

As the most well-known analytical tool, the thermometer has been extended to the field of biological analysis based on the photothermal effect. Herein, isoniazide modified Ag nanoparticles were prepared as nanolabels to build an immunoassay. The nanoparticles were characterized by transmission electron microscope (TEM), dynamic laser scattering (DLS), X-ray powder diffraction (XRD), and Fourier transform infrared (FT-IR). When the target protein was present, the sandwich immunoassay was developed and the photothermal reaction was triggered by isoniazide modified Ag nanoparticles. As a reducing agent, isoniazide is used to transform phosphomolybdic acid hydrate into molybdenum blue solution. And molybdenum blue had good photothermal stability and high photothermal conversion efficiency. The temperature variation of molybdenum blue solution showed a positive correlation with the concentration of carcinoembryonic antigen (CEA). Thus, the target protein of CEA was quantitative detection by thermometer. The linear response range is 0.1 ng mL-1 to 40 ng mL-1, and the detection limit is 0.08 ng mL-1. Moreover, the proposed protocol had satisfactory selectivity, accuracy, and reproducibility.


Assuntos
Antígeno Carcinoembrionário , Nanopartículas Metálicas , Antígeno Carcinoembrionário/análise , Reprodutibilidade dos Testes , Espectroscopia de Infravermelho com Transformada de Fourier , Prata , Imunoensaio/métodos , Limite de Detecção , Ouro
19.
Pancreatology ; 23(7): 868-877, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37230894

RESUMO

BACKGROUND: Mucinous pancreatic cysts harbor the potential to progress to highly lethal pancreatic ductal adenocarcinoma (PDAC). Since these precursor cysts require cancer surveillance or surgical resection, they need to be reliably distinguished from harmless pancreatic cysts. Current clinical and radiographic assessment is imperfect and the value of cyst fluid analysis for differential diagnosis is unclear. Therefore, we set out to investigate the value of cyst fluid biomarkers in distinguishing pancreatic cysts. METHODS: We performed a systematic review of the current literature to identify articles that evaluated the diagnostic performance of clinically relevant and promising candidate cyst fluid biomarkers, with a particular emphasis on DNA-based biomarkers. Meta-analysis was performed for biomarkers targeted at identifying cyst type and presence of high-grade dysplasia or PDAC. RESULTS: Data from a total of 42 studies was analyzed. Mutations in KRAS and/or GNAS allowed identification of mucinous cysts with a sensitivity of 79% and specificity of 98%. This exceeded the performance of the traditional biomarker carcinoembryonic antigen (CEA; sensitivity 58%, specificity 87%). Mutations in VHL were specific for serous cystadenomas (SCAs; sensitivity 56%, specificity 99%) and help to exclude mucinous cysts. Mutations in CDKN2A, PIK3CA, SMAD4, and TP53 each had high specificities of 97%, 97%, 98%, and 95%, respectively, to identify high-grade dysplasia or PDAC in mucinous cysts. CONCLUSIONS: Cyst fluid analysis can be a valuable tool in the characterization of pancreatic cysts, with relevant clinical implications. Our results support the use of DNA-based cyst fluid biomarkers in the multidisciplinary diagnostic work-up of pancreatic cysts.


Assuntos
Carcinoma Ductal Pancreático , Cisto Pancreático , Neoplasias Pancreáticas , Humanos , Líquido Cístico/química , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/patologia , Antígeno Carcinoembrionário/análise , Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/genética , Carcinoma Ductal Pancreático/patologia , Cisto Pancreático/diagnóstico , Cisto Pancreático/genética , Cisto Pancreático/patologia , DNA , Biomarcadores Tumorais/genética , Biomarcadores Tumorais/análise , Neoplasias Pancreáticas
20.
Analyst ; 148(9): 1939-1947, 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-36916483

RESUMO

Diagnosis of cancer by biomarkers plays an important role in human health and life. However, current laboratory techniques for detecting cancer biomarkers still require laborious and time-consuming operation by skilled operators and associated laboratory instruments. This work presents a colorimetric biosensor for the rapid and sensitive detection of carcinoembryonic antigen (CEA) based on an automated immunomagnetic separation platform and a droplet array microfluidic chip with the aid of an image analysis system. Immunomagnetic nanoparticles (MNPs) were used to capture CEA in the samples. CEA-detecting antibodies and horseradish peroxidase (HRP) were modified on polystyrene microspheres (PS), catalysing hydrogen peroxide and 3,3',5,5'-tetramethylbenzidine (TMB) as signal outputs. Color reaction data were analyzed to establish a CEA concentration standard curve. The movement of MNPs between droplets in the microfluidic chip is achieved using an automatically programmable magnetic control system. This colorimetric biosensor has been used for the simultaneous detection of six CEA samples ranging from 100 pg mL-1 to 100 ng mL-1 with a detection limit of 14.347 pg mL-1 in 10 min, following the linear equation: y = -4.773 ln(x) + 156.26 with a correlation of R2 = 0.9924, and the entire workflow can be completed within 80 minutes. The microfluidic immunosensor designed in this paper has the advantages of low cost, automation, low sample consumption, high throughput, and promising applications in biochemistry.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Humanos , Antígeno Carcinoembrionário/análise , Separação Imunomagnética/métodos , Microfluídica , Imunoensaio/métodos , Técnicas Biossensoriais/métodos , Anticorpos Monoclonais , Limite de Detecção , Ouro
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa