RESUMO
OBJECTIVE: To perform non-invasive Electroarthrography (EAG) on live horses and establish relationships between EAG and direct measurements of cartilage streaming potentials in weight bearing areas of the equine metacarpophalangeal joint. DESIGN: EAG was performed bilaterally on the metacarpophalangeal joints of live horses (n = 3). Separate experiments used metacarpophalangeal joint explants (n = 11) to measure EAG obtained during simulated loading followed by direct measurements of cartilage streaming potentials on joint surfaces using the Arthro-BST probe. Joints were assigned to relatively normal (n = 5) and mildly degraded (n = 6) groups based on histological scoring of Safranin-O/Fast Green stained sections. RESULTS: EAG, involving application of electrodes to skin surrounding the joint and repeated weight shifting, was well-tolerated in live horses. One pair of distal forelimbs were available for analogous ex vivo EAG testing and measurements were strongly correlated to in vivo EAG measurements obtained on the same joints (r = 0.804, p = 0.016, n = 8). Both indirect (EAG) and direct (Arthro-BST) measurements of cartilage streaming potentials distinguished between normal and mildly degraded cartilage with statistically significant differences at 5 of 6 and 4 of 6 electrodes during simulated standing and walking, respectively. Strong and moderate correlations for weight bearing regions on the dorsal phalanx and central metacarpus were detected during both standing and walking. At the metacarpus/sesamoid interface a moderate correlation occurred during walking. CONCLUSION: Non-invasive EAG was used successfully in a clinical scenario and correlated to direct measurements of streaming potentials in weight bearing cartilage. These data support the potential of EAG to contribute to the diagnosis and treatment of degenerative joint diseases.
Assuntos
Cartilagem Articular , Articulação Metacarpofalângica , Suporte de Carga , Animais , Cavalos , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/fisiologia , Articulação Metacarpofalângica/diagnóstico por imagem , Articulação Metacarpofalângica/fisiologia , Articulação Metacarpofalângica/fisiopatologia , Suporte de Carga/fisiologia , Artrografia/métodos , Membro Anterior/fisiologiaRESUMO
OBJECTIVE: To assess the applicability of a semiquantitative index for symptomatic minor instability of the lateral elbow (SMILE). MATERIALS AND METHODS: CT arthrograms of consecutive patients with lateral elbow pain who underwent ultrasound-guided CT arthrography at our orthopedic center between April 2019 and May 2022 were included. Images were acquired at 100 kVp and 80 mAs. An expert radiologist (R1) and a radiology resident (R2) retrospectively performed an independent, blinded evaluation of the arthrograms to assess the presence of imaging findings suggestive of elbow instability. The SMILE index (0-8) was obtained adding (I) radial head chondromalacia (0 - 1); (II) humeral capitellum chondromalacia (0 - 1); (III) humeral trochlear ridge chondromalacia (0 - 1); (IV) annular ligament laxity (0 - 2); (V) synovial thickening (0 - 1); (VI) humeroradial joint asymmetry (0 - 1); and (VII) capsular tear (0 - 1). R1 repeated the assessment after 14 days. Cohen's weighted κ statistic and raw concordance were used to appraise reproducibility. RESULTS: Eighty patients (median age 49 years, interquartile range 40-53 years, 49, 61% males) underwent CT arthrography at our center, and 10 (12%) of them underwent bilateral elbow examination, leading to 90 included CT arthrograms. Median SMILE index was 4 (IQR: 2-5) for R1, 4 (IQR: 2-5) for R2, and 4 (IQR: 2-5) for the second assessment by R1. Intra-reader agreement was excellent (κ = 0.94, concordance 87%), while inter-reader agreement was substantial (κ = 0.75, concordance 67%). CONCLUSION: The proposed SMILE index showed good reproducibility; further studies are warranted to correlate our index with clinical and surgical data. CLINICAL RELEVANCE STATEMENT: Our scoring system allows a standardized evaluation of patients with lateral elbow pain and instability suitable for application into clinical practice, complementing the orthopedic surgeon's clinical diagnosis with imaging findings that may aid treatment choices. KEY POINTS: ⢠Lateral elbow pain is often interpreted clinically as lateral epicondylitis, but it can also encompass intra-articular pathology. ⢠The proposed arthrographic index allows comprehensive quantification of lateral elbow pathology with good reproducibility and application times. ⢠Our index provides the orthopedic surgeon with information regarding intra-articular findings, aiding treatment choices.
Assuntos
Doenças das Cartilagens , Articulação do Cotovelo , Instabilidade Articular , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Feminino , Cotovelo , Articulação do Cotovelo/patologia , Artrografia/métodos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Instabilidade Articular/diagnóstico por imagem , Artralgia , Dor , Tomografia Computadorizada por Raios X , Doenças das Cartilagens/patologiaRESUMO
AIM: To compare the image quality of virtual noncontrast (VNC) and true noncontrast (TNC) CT images and to evaluate the clinical feasibility of VNC CT images for assessing osteochondral lesions of the talus (OLTs). MATERIALS AND METHODS: Forty-five OLT patients who underwent ankle CT arthrography (CTA) using dual-layer spectral detector CT were enrolled. Reconstruction of VNC and three-dimensional volume rendering images was performed. Afterward, image noise, the signal-to-noise ratio (SNR), and the contrast-to-noise ratio (CNR) were measured. For the subjective evaluation, two board-certified musculoskeletal radiologists [R2-1] assessed spatial resolution, overall image quality, and lesion conspicuity. The accuracy rate for OLT grading was determined in 23 patients who underwent arthroscopic surgery. RESULTS: While VNC images showed significantly less noise than TNC images, TNC images showed better SNRs and CNRs (p<.01). In the subjective analysis, TNC images showed better overall image quality (p<.001). For the 3D volume rendering images, VNC images scored significantly higher for lesion conspicuity (p<.001). The accuracy rates of CTA and CTA with VNC images for OLT grading were 79.2% and 83.3%, respectively. Regarding confidence level, when CTA and VNC images were evaluated together, the confidence level was significantly higher than that when only CTA images were evaluated (p<.001). CONCLUSION: VNC imaging can provide better confidence level of OLT grading and evaluation of the integrity of the subchondral bone plate when combined with conventional CTA without additional radiation dose to the patient. In addition, VNC images-based 3D volume rendering reconstruction would be helpful for preoperative planning in OLT patients.
Assuntos
Artrografia , Estudos de Viabilidade , Tálus , Tomografia Computadorizada por Raios X , Humanos , Tálus/diagnóstico por imagem , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Artrografia/métodos , Imageamento Tridimensional/métodos , Adulto Jovem , Idoso , Adolescente , Razão Sinal-Ruído , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodosRESUMO
OBJECTIVE: To determine the preferred ankle, knee, and elbow arthrography injection techniques for Society of Skeletal Radiology (SSR) members and whether more recently described techniques are gaining acceptance. We also sought to determine whether the concept of knowledge translation might explain differences between the preferred technique, year of fellowship graduation, and year the newer technique was described. MATERIALS AND METHODS: A 29-question survey was created in Qualtrics and submitted to current SSR members to determine if they perform knee, elbow, and ankle arthrography, and if so, the year of fellowship completion and preferred approaches. Survey respondents indicated the starting and ending needle tip positions for three knee, two elbow, and three ankle arthrography approaches using grids placed over provided frontal and lateral radiographs. RESULTS: Two hundred seventy-four SSR members (mean post-fellowship 13 years; range 0-38) completed the survey and performed fluoroscopic-guided knee (93%), elbow (95%), and ankle (75%) arthrography. Preferred approaches included the following: knee lateral subpatellar (43%), anterior (40%); elbow radiocapitellar (74%); ankle anterior/peritendon (70%), lateral mortise (24%). Preference of newer technique was related to fellowship graduation year and publication year for the ankle mortise (26% before, 42% after; p = 0.03) and posterior trans-triceps elbow articles (19% before, 33% after; p < 0.01). The anterior knee approach preference increased from 11% in 2008 to 40% (p ≤ 0.001). CONCLUSION: Nearly twice as many SSR members who graduated after the posterior trans-triceps and ankle mortise techniques were published prefer them for performing arthrography, possibly due to knowledge translation. The preference of the anterior knee arthrography approach has increased nearly fourfold since 2008.
Assuntos
Artrografia , Radiologia , Humanos , Artrografia/métodos , Tornozelo , Cotovelo , Injeções Intra-Articulares/métodosRESUMO
OBJECTIVE: Direct magnetic resonance arthrography (dMRA) is often considered the most accurate imaging modality for the evaluation of intra-articular structures, but utilization and performance vary widely without consensus. The purpose of this white paper is to develop consensus recommendations on behalf of the Society of Skeletal Radiology (SSR) based on published literature and expert opinion. MATERIALS AND METHODS: The Standards and Guidelines Committee of the SSR identified guidelines for utilization and performance of dMRA as an important topic for study and invited all SSR members with expertise and interest to volunteer for the white paper panel. This panel was tasked with determining an outline, reviewing the relevant literature, preparing a written document summarizing the issues and controversies, and providing recommendations. RESULTS: Twelve SSR members with expertise in dMRA formed the ad hoc white paper authorship committee. The published literature on dMRA was reviewed and summarized, focusing on clinical indications, technical considerations, safety, imaging protocols, complications, controversies, and gaps in knowledge. Recommendations for the utilization and performance of dMRA in the shoulder, elbow, wrist, hip, knee, and ankle/foot regions were developed in group consensus. CONCLUSION: Although direct MR arthrography has been previously used for a wide variety of clinical indications, the authorship panel recommends more selective application of this minimally invasive procedure. At present, direct MR arthrography remains an important procedure in the armamentarium of the musculoskeletal radiologist and is especially valuable when conventional MRI is indeterminant or results are discrepant with clinical evaluation.
Assuntos
Artrografia , Imageamento por Ressonância Magnética , Humanos , Artrografia/métodos , Radiografia , Imageamento por Ressonância Magnética/métodos , Ombro/diagnóstico por imagem , PunhoRESUMO
PURPOSE: The purpose of this study is to describe the anterior injection approach, with anatomical landmark guidance, for direct MR arthrography (dMRA) of the hip joint, and to evaluate the effectiveness in joint distension and the security of the technique. MATERIAL AND METHODS: Retrospective review of hip dMRAs was conducted on patients with suspected intra-articular pathology from two MR outpatient centers, performed by two radiologists with 25 and 5 years of experience, respectively. The analysis included assessing the presence of intra-articular contrast material (gadolinium-based solution), the number of injections performed, the degree of joint distension, and the degree of contrast extravasation. A multi-variant analysis was carried out to determine if the procedure success depend on any of the demographic variants or on the radiologist experience. Additionally, the presence of immediate and medium-term post-puncture complications was evaluated. RESULTS: One hundred patients with 104 hip dMRA were included; 60 were men, with mean age of 38 years (16-63 years). Contrast material was successfully introduced intra-articularly in 100% of patients, being necessary a second puncture only in 6% of procedures. The capsular distension was considered optimal for diagnosis in 97% of cases. Different degrees of contrast extravasation were found in 30% of dMRA. There was no statistically significant relationship observed between patient variables and the performance of dMRA, nor did it show any correlation with the experience of the radiologists. No puncture-derived complications were found. CONCLUSION: Hip dMRA through anterior injection guided by anatomical references is an effective and safe alternative for patients with suspected intra-articular pathology.
Assuntos
Artrografia , Meios de Contraste , Masculino , Humanos , Adulto , Feminino , Artrografia/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Imageamento por Ressonância Magnética/métodos , Injeções , Injeções Intra-ArticularesRESUMO
OBJECTIVE: To describe the aponeurotic expansion of supraspinatus tendon (AEST) and biceps tendon abnormalities with magnetic resonance (MR) arthrographic examinations and determine their prevalence in patients, we performed a high-resolution 3D direct MR arthrography. MATERIALS AND METHODS: This was a retrospective study of 700 shoulder MR arthrograms performed between May 2010 and January 2022. Extension in the coronal plane of an AEST on 3D fat-suppressed T1-weighted volumetric interpolated breath-hold examination (VIBE) MR arthrography was identified. Based on its morphology, the AEST on MR arthrography was divided into four subtypes: absence of tendinous thickness in the bicipital synovial surface or intra-synovial tendon-like structure in the bicipital groove, thin and flat tendinous thickness ≥1 mm of bicipital synovium, oval tendinous structure less than half the size of the adjacent biceps tendon, oval tendinous structure more than half the size of the adjacent biceps tendon, and oval tendinous structure larger than the adjacent biceps tendon. Based on its origin and termination, aponeurotic expansions can be divided into three subtypes: proximal pulley zone, middle humeral neck zone, and distal myotendinous junction zone. Association with the biceps synovium of the AEST was categorized into three types: intra-synovial, extra-synovial, and trans-synovial. RESULTS: An AEST in the anterior shoulder joint in 3D VIBE MR arthrography images was identified in 63 (9%) of 700 arthrograms. The most common arthrographic type of AEST was type 1-this was detected in 39 of 63 patients. The most common course type of the AEST was anteriorly midline. The most common distal insertion type was at the tenosynovial sheath of the long head of the biceps tendon (LHBT) in the middle humeral neck zone-this was detected in 31 of 63 patients. There were only 10 MR arthrograms biceps tendon abnormality, including 4 biceps agenesis and 6 split ruptures. CONCLUSION: A 2D and high-resolution 3D MR arthrography can demonstrate the anatomical detail around the bicipital groove and facilitate the differentiation between a biceps tendon anomaly and an AEST. On high-resolution 3D MR arthrographic images, the AEST tends to be in the anterior midline and anteromedial portions of the biceps synovium with intra-synovial, extra-synovial, and trans-synovial courses and its three different insertion types.
Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Artrografia/métodos , Manguito Rotador , Estudos Retrospectivos , Tendões/diagnóstico por imagem , Tendões/patologia , Imageamento por Ressonância Magnética/métodos , Articulação do Ombro/anatomia & histologia , Espectroscopia de Ressonância Magnética , Lesões do Manguito Rotador/patologiaRESUMO
OBJECTIVES: In this study, we aimed to compare conventional and T1-weighted volumetric magnetic resonance arthrography (MRA) in the diagnosis and grading of glenoid cartilage defects that accompany labral pathologies. MATERIALS AND METHODS: A total of 79 patients who were prediagnosed with labrum pathologies based on shoulder magnetic resonance imaging (MRI) had MRA and CTA between December 2021 and May 2022. CTA was regarded as reference standard. CTA images were examined by a radiologist experienced in musculoskeletal radiology, and MRA images were examined by two radiologists independently to determine presence, grade, and localization of any glenoid cartilage defect, if present. Sensitivity, specificity, and accuracy were calculated separately for conventional and T1-weighted volumetric MRA. In addition, at the last stage, two observers examined all MRAs together, and the presence of a cartilage defect was decided by consensus, and the overall sensitivity, specificity, and accuracy were calculated. RESULTS: Cartilage defect was detected on CTAs of 48 (60.75%) cases of among 79 patients with labrum pathology. The sensitivity, specificity, and accuracy of conventional MRA for two examiners were 17-19%, 100-100%, and 49-51%, respectively, while those values were 67-65%, 92-97%, and 84-77%, respectively, for T1-weighted volumetric MRA. Inter-examiner agreement was excellent for diagnosis of cartilage defects on all MRAs. The overall sensitivity, specificity, and accuracy for detection of glenoid cartilage lesions by MRA were 69%, 97%, and 80%, respectively. CONCLUSION: T1-weighted volumetric MRA seems to demonstrate cartilage defects accompanied with labrum pathologies accurately with high sensitivity, specificity, and excellent inter-examiner agreement.
Assuntos
Doenças das Cartilagens , Articulação do Ombro , Humanos , Artrografia/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/patologia , Doenças das Cartilagens/diagnóstico por imagem , Doenças das Cartilagens/patologia , Imageamento por Ressonância Magnética/métodos , Sensibilidade e EspecificidadeRESUMO
PURPOSE: To evaluate the distribution of intra- and extraarticular MRI findings in children and adolescents with clinically suspected intraarticular cause of hip pain in order to assess the need for additional intraarticular contrast administration. MATERIAL AND METHODS: Database was searched over a period of 34 months retrospectively for consecutive hip MR arthrography in young patients (8-17 years) with suspected intraarticular cause of hip or groin pain. Exclusion criteria were prior hip surgery, follow-up examination due to known intraarticular pathology, incomplete examination, qualitatively non-diagnostic examinations, and missing informed consent. Reports of fellowship-trained MSK radiologists were searched for intraarticular versus extraarticular findings explaining hip or groin pain. RESULTS: Seventy patients (68% female; median age: 14.5 years; range:10.8-16.9 years) were analyzed. No reason for pain was found in 30 (42.9%) hips, extraarticular reasons in 20 (28.6%) cases, intraarticular in 14 (20.0%), and both (intra- and extraarticular) in 6 (8.6%) hips. Most common extraarticular reasons were apophysitis (14.3%), other bony stress reactions (12.9%), intramuscular edema (7%), tendinitis (5.7%), and trochanteric bursitis (4.3%). Labral pathology was the most common intraarticular finding (overall:34.3%; partial tear:15.7%, complete tear:15.7%), most frequent at the anterosuperior position (81.8%). Cartilage defects (1.4%), intraarticular neoplasia (1.4%), and tear of the femoral head ligament (2.8%) were rarely found. Synovitis and loose bodies were not observed. Cam-(37.1%) and pincer-configurations (47.1%) were common while hip dysplasia was rare (5.7%). CONCLUSION: MRI in children and adolescents with hip pain should be done primarily without intraarticular contrast administration since most cases show an extraarticular pain reason or no diagnosis detectable with MRI.
Assuntos
Artralgia , Meios de Contraste , Articulação do Quadril , Imageamento por Ressonância Magnética , Humanos , Adolescente , Feminino , Masculino , Criança , Imageamento por Ressonância Magnética/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Artralgia/diagnóstico por imagem , Artralgia/etiologia , Reprodutibilidade dos Testes , Artrografia/métodos , Sensibilidade e Especificidade , Estudos Retrospectivos , Artropatias/diagnóstico por imagemRESUMO
PURPOSE: To determine the comparative accuracy and precision of routine magnetic resonance imaging (MRI) versus magnetic resonance (MR) arthrogram in measuring labral tear size as a function of time from a shoulder dislocation. METHODS: We retrospectively evaluated consecutive patients who underwent primary arthroscopic stabilization between 2012 and 2021 in a single academic center. All patients completed a preoperative MRI or MR arthrogram of the shoulder within 60 days of injury and subsequently underwent arthroscopic repair within 6 months of imaging. Intraoperative labral tear size and location were used as standards for comparison. Three musculoskeletal radiologists independently interpreted tear extent using a clock-face convention. Accuracy and precision of MR labral tear measurements were defined based on location and size of the tear, respectively. Accuracy and precision were compared between MRI and MR arthrogram as a function of time from dislocation. RESULTS: In total, 32 MRIs and 65 MR arthrograms (total n = 97) were assessed. Multivariate analysis demonstrated that intraoperative tear size, early imaging, and arthrogram status were associated with increased MR accuracy and precision (P < .05). Ordering surgeons preferred arthrogram for delayed imaging (P = .018). For routine MRI, error in accuracy increased by 3.4° per day and error in precision increased by 2.3° per day (P < .001) from time of injury. MR arthrogram, however, was not temporally influenced. Significant loss of accuracy and precision of MRI compared with MR arthrogram occurred at 2 weeks after an acute shoulder dislocation. CONCLUSIONS: Compared with MR arthrogram, conventional MRI demonstrates time-dependent loss of accuracy and precision in determining shoulder labral tear extent after dislocation, with statistical divergence occurring at 2 weeks. LEVEL OF EVIDENCE: Level II, retrospective radiographic diagnostic study.
Assuntos
Imageamento por Ressonância Magnética , Luxação do Ombro , Humanos , Estudos Retrospectivos , Masculino , Feminino , Adulto , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Artroscopia , Pessoa de Meia-Idade , Artrografia/métodos , Adulto Jovem , Fatores de Tempo , Lesões do Ombro/diagnóstico por imagemRESUMO
Recent research shows that magnetic resonance arthrogram offers better definition of certain shoulder pathology, especially labral tears, compared with magnetic resonance imaging (MRI). Conventional MRI accuracy and precision deteriorate after 2 weeks, and few health delivery environments achieve MRI within 14 days of a shoulder dislocation. Moreover, further loss of MRI accuracy is time dependent. Although magnetic resonance arthrogram should be considered a first-line imaging study when evaluating shoulder instability more than 2 weeks after the patient's injury, one must also consider clinical value and cost-effectiveness.
Assuntos
Imageamento por Ressonância Magnética , Luxação do Ombro , Humanos , Luxação do Ombro/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Instabilidade Articular/diagnóstico por imagem , Lesões do Ombro/diagnóstico por imagem , Artrografia/métodosRESUMO
PURPOSE: MR arthrography (MRA) is the most accurate method for preoperatively diagnosing superior labrum anterior-posterior (SLAP) lesions, but diagnostic results can vary considerably due to factors such as experience. In this study, deep learning was used to facilitate the preliminary identification of SLAP lesions and compared with radiologists of different seniority. METHODS: MRA data from 636 patients were retrospectively collected, and all patients were classified as having/not having SLAP lesions according to shoulder arthroscopy. The SLAP-Net model was built and tested on 514 patients (dataset 1) and independently tested on data from two other MRI devices (122 patients, dataset 2). Manual diagnosis was performed by three radiologists with different seniority levels and compared with SLAP-Net outputs. Model performance was evaluated by the receiver operating characteristic (ROC) curve, area under the ROC curve (AUC), etc. McNemar's test was used to compare performance among models and between radiologists' models. The intraclass correlation coefficient (ICC) was used to assess the radiologists' reliability. p < 0.05 was considered statistically significant. RESULTS: SLAP-Net had AUC = 0.98 and accuracy = 0.96 for classification in dataset 1 and AUC = 0.92 and accuracy = 0.85 in dataset 2. In dataset 1, SLAP-Net had diagnostic performance similar to that of senior radiologists (p = 0.055) but higher than that of early- and mid-career radiologists (p = 0.025 and 0.011). In dataset 2, SLAP-Net had similar diagnostic performance to radiologists of all three seniority levels (p = 0.468, 0.289, and 0.495, respectively). CONCLUSIONS: Deep learning can be used to identify SLAP lesions upon initial MR arthrography examination. SLAP-Net performs comparably to senior radiologists.
Assuntos
Aprendizado Profundo , Lesões do Ombro , Articulação do Ombro , Humanos , Ombro/diagnóstico por imagem , Artrografia/métodos , Lesões do Ombro/diagnóstico por imagem , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/patologia , Artroscopia , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: To assess diagnostic value and clinical utility of multidetector computed tomographic positive contrast arthrography (CTA) for meniscal lesions in dogs. STUDY DESIGN: Prospective case series. STUDY POPULATION: Client-owned dogs (n = 55) with cranial cruciate ligament injuries. METHODS: Sedated dogs underwent CTA using a 16-slice scanner, and subsequently received mini-medial arthrotomy for meniscal assessment. Scans were anonymized, randomized, and reviewed twice for meniscal lesions by three independent observers with varying experience. Results were compared with surgical findings. Reproducibility and repeatability were assessed with kappa statistics, intraobserver changes in diagnosis by McNemar's test, and interobserver differences using Cochran's Q test. Test performance was calculated using sensitivity, specificity, proportion correctly identified, and positive and negative predictive values and likelihood ratios. RESULTS: Analysis was based on 52 scans from 44 dogs. Sensitivity for identifying meniscal lesions was 0.62-1.00 and specificity was 0.70-0.96. Intraobserver agreement was 0.50-0.78, and interobserver agreement was 0.47-0.83. There was a significant change between readings one and two for the least experienced observers (p < .05). The sum of sensitivity and specificity exceeded 1.5 for both readings and all observers. CONCLUSION: Diagnostic performance was suitable for identifying meniscal lesions. An effect of experience and learning was seen in this study.
Assuntos
Lesões do Ligamento Cruzado Anterior , Doenças do Cão , Humanos , Cães , Animais , Artrografia/veterinária , Artrografia/métodos , Joelho de Quadrúpedes/cirurgia , Ligamento Cruzado Anterior/cirurgia , Reprodutibilidade dos Testes , Meniscos Tibiais/cirurgia , Meios de Contraste , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/veterinária , Sensibilidade e Especificidade , Artroscopia/veterinária , Doenças do Cão/diagnóstico por imagemRESUMO
Background and Objectives: This study aimed to compare capsular volume in patients with shoulder instability to that in control subjects without instability using magnetic resonance (MR) arthrography. The objective was to develop a reliable screening method with which to assess shoulder volume. Materials and Methods: In 21 patients with atraumatic shoulder instability and 21 controls, thin-slice 3D volumetric MR arthrography sequences were obtained. MR arthrography images were uploaded to 3D reconstruction, and 3D images were generated. From the 3D reconstructed images, volumetric measurements of rotator interval (RI), anterior and posterior capsular (AC, PC) recesses, biceps tendon sheath (BS), axillary recess (AR), and total glenohumeral joint (TGJ) were performed. Individuals with any extra-articular contrast leakage were also recorded. Results: A retrospective study analyzed a patient group of 21 individuals with shoulder instability (mean age 29.52 ± 12.83 years) and a control group of 21 individuals without instability (mean age 35.71 ± 12.77 years). No statistically significant differences were identified between the groups with regard to age, gender, or side distribution. The mean total joint volume was significantly higher in the instability group (29.85 ± 6.40 cm3) compared to the control group (23.15 ± 3.48 cm3, p = 0.0001). Additionally, the mean volumes of the RI, AC, PC, BS, and AR were all significantly greater in the patient group compared to the control group. Conclusions: 3D volumetric MR arthrographic measurements of the shoulder joint capacity can provide valuable insights for clinical follow-up and guide surgical treatment decisions in cases of atraumatic shoulder instability.
Assuntos
Imageamento Tridimensional , Instabilidade Articular , Imageamento por Ressonância Magnética , Articulação do Ombro , Humanos , Feminino , Masculino , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/fisiopatologia , Adulto , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Artrografia/métodos , Estudos de Casos e ControlesRESUMO
Background and Objectives: This study aimed to evaluate the relationship between SLAP lesions and the shoulder joint capsule thickness via MR arthrography. Understanding the relationship between SLAP lesions and the joint capsule thickness is important because an increased capsule thickness may indicate chronic inflammation and contribute to persistent pain and dysfunction. These findings have significant clinical implications for the diagnosis, management, and treatment strategies of shoulder joint pathologies. Materials and Methods: We retrospectively analyzed the MR arthrography results of 78 patients who underwent shoulder imaging at Düzce University Medical Faculty between October 2021 and November 2024. The study included patients diagnosed with SLAP lesions and compared them with a control group without such pathology. Data on joint capsule thickness at the level of the axillary recess, SLAP lesion type, cuff pathology, and demographic information were collected and analyzed. Results: The study included 32 patients with SLAP lesions and 46 control subjects. The mean age of the patients was 44.75 ± 14.18 years, whereas the control group had a mean age of 38.76 ± 13 years. The patient group presented a significantly greater mean anterior capsule thickness (3.13 ± 1.28 mm vs. 1.72 ± 0.7 mm, p = 0.0001), posterior capsule thickness (3.35 ± 1.32 mm vs. 1.95 ± 1.06 mm, p = 0.0001), and maximum capsule thickness (3.6 ± 1.32 mm vs. 2.06 ± 1.01 mm, p = 0.0001) in the axillary recess. SLAP type 2 lesions were the most common type (43.76%) in the patient group. Conclusions: This study revealed a significant association between SLAP lesions and an increased shoulder joint capsule thickness. These findings suggest that MR arthrography is an effective tool for assessing the joint capsule changes associated with labral tears, contributing to the better diagnosis and management of shoulder joint pathologies in clinical practice.
Assuntos
Cápsula Articular , Imageamento por Ressonância Magnética , Articulação do Ombro , Humanos , Feminino , Masculino , Adulto , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Cápsula Articular/diagnóstico por imagem , Cápsula Articular/patologia , Estudos Retrospectivos , Artrografia/métodos , Estudos de Casos e Controles , Lesões do Ombro/diagnóstico por imagemRESUMO
OBJECTIVES: To determine the diagnostic accuracy of non-arthrographic MR imaging, conventional MR arthrography, and 3D T1-weighted volumetric interpolated breath-hold examination (VIBE) MR arthrography sequences as compared with a CT arthrography in the diagnosis of glenoid bare spot. METHODS: A retrospective study of 216 patients who underwent non-arthrographic MR imaging, conventional MR arthrography, VIBE MRI arthrography, and CT arthrogram between January 2011 and March 2022 was conducted. The diagnostic accuracy of non-arthrographic MR imaging, direct MR arthrography, and VIBE MRI arthrography in the detection of glenoid bare spot was compared with that of CT arthrography. All studies were reviewed by 2 MSK radiologists. Interobserver agreement for MR imaging and MR arthrographic findings was calculated. RESULTS: Sixteen of 216 patients were excluded. Twenty-three of 200 shoulders had glenoid bare spot on CT arthrographic images. The glenoid bare spot was detected in 11 (47.8%) and 7 (30.4%) patients on conventional non-arthrographic MR images and in 18 (78.3%) and 16 (69.6%) patients on conventional MR arthrograms by observers 1 and 2, respectively. Both observers separately described the bare spot in 22 of 23 patients (95.7%) on 3D volumetric MR arthrograms. Interobserver variabilities were fair agreement for conventional non-arthrographic MR imaging (κ = 0.35, p < 0.05), moderate agreement for conventional MR arthrogram (κ = 0.50, p < 0.05), and near-perfect agreement for 3D volumetric MR arthrogram reading (κ = 0.87, p < 0.05). CONCLUSIONS: A 3D high-resolution T1-weighted VIBE MR arthrography sequence may yield diagnostic performance that is comparable with that of CT arthrography in the diagnosis of glenoid bare spot. KEY POINTS: â¢Glenoid bare spot should not be misdiagnosed as a transchondral defect of the glenoid surface by radiologists. â¢A 3D high-resolution T1-weighted VIBE MR arthrography sequence may be used as a high-sensitivity imaging technique in the diagnosis of glenoid bare spot.
Assuntos
Artrografia , Imageamento Tridimensional , Humanos , Artrografia/métodos , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios XRESUMO
OBJECTIVE: To compare image quality and diagnostic performance of preoperative direct hip magnetic resonance arthrography (MRA) performed with gadolinium contrast agent and saline solution. METHODS: IRB-approved retrospective study of 140 age and sex-matched symptomatic patients with femoroacetabular impingement, who either underwent intra-articular injection of 15-20 mL gadopentetate dimeglumine (GBCA), 2.0 mmol/L ("GBCA-MRA" group, n = 70), or 0.9% saline solution ("Saline-MRA" group, n = 70) for preoperative hip MRA and subsequent hip arthroscopy. 1.5 T hip MRA was performed including leg traction. Two readers assessed image quality using a 5-point Likert scale (1-5, excellent-poor), labrum and femoroacetabular cartilage lesions. Arthroscopic diagnosis was used to calculate diagnostic accuracy which was compared between groups with Fisher's exact tests. Image quality was compared with the Mann-Whitney U tests. RESULTS: Mean age was 33 years ± 9, 21% female patients. Image quality was excellent (GBCA-MRA mean range, 1.1-1.3 vs 1.1-1.2 points for Saline-MRA) and not different between groups (all p > 0.05) except for image contrast which was lower for Saline-MRA group (GBCA-MRA 1.1 ± 0.4 vs Saline-MRA 1.8 ± 0.5; p < 0.001). Accuracy was high for both groups for reader 1/reader 2 for labrum (GBCA-MRA 94%/ 96% versus Saline-MRA 96%/93%; p > 0.999/p = 0.904) and acetabular (GBCA-MRA 86%/ 83% versus Saline-MRA 89%/87%; p = 0.902/p = 0.901) and femoral cartilage lesions (GBCA-MRA 97%/ 99% versus Saline-MRA 97%/97%; both p > 0.999). CONCLUSION: Diagnostic accuracy and image quality of Saline-MRA and GBCA-MRA is high in assessing chondrolabral lesions underlining the potential role of non-gadolinium-based hip MRA. KEY POINTS: ⢠Image quality of Saline-MRA and GBCA-MRA was excellent for labrum, acetabular and femoral cartilage, ligamentum teres, and the capsule (all p > 0.18). ⢠The overall image contrast was lower for Saline-MRA (Saline-MRA 1.8 ± 0.5 vs. GBCA-MRA 1.1 ± 0.4; p < 0.001). ⢠Diagnostic accuracy was high for Saline-MRA and GBCA-MRA for labrum (96% vs. 94%; p > 0.999), acetabular cartilage damage (89% vs. 86%; p = 0.902), femoral cartilage damage (97% vs. 97%; p > 0.999), and extensive cartilage damage (97% vs. 93%; p = 0.904).
Assuntos
Artrografia , Cartilagem Articular , Humanos , Feminino , Adulto , Masculino , Artrografia/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Meios de Contraste/farmacologia , Projetos Piloto , Gadolínio/farmacologia , Estudos Retrospectivos , Solução Salina , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Acetábulo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Artroscopia/métodosRESUMO
OBJECTIVES: The purpose of this agreement was to establish evidence-based consensus statements on imaging of distal radioulnar joint (DRUJ) instability and triangular fibrocartilage complex (TFCC) injuries by an expert group using the Delphi technique. METHODS: Nineteen hand surgeons developed a preliminary list of questions on DRUJ instability and TFCC injuries. Radiologists created statements based on the literature and the authors' clinical experience. Questions and statements were revised during three iterative Delphi rounds. Delphi panelists consisted of twenty-seven musculoskeletal radiologists. The panelists scored their degree of agreement to each statement on an 11-item numeric scale. Scores of "0," "5," and "10" reflected complete disagreement, indeterminate agreement, and complete agreement, respectively. Group consensus was defined as a score of "8" or higher for 80% or more of the panelists. RESULTS: Three of fourteen statements achieved group consensus in the first Delphi round and ten statements achieved group consensus in the second Delphi round. The third and final Delphi round was limited to the one question that did not achieve group consensus in the previous rounds. CONCLUSIONS: Delphi-based agreements suggest that CT with static axial slices in neutral rotation, pronation, and supination is the most useful and accurate imaging technique for the work-up of DRUJ instability. MRI is the most valuable technique in the diagnosis of TFCC lesions. The main indication for MR arthrography and CT arthrography are Palmer 1B foveal lesions of the TFCC. CLINICAL RELEVANCE STATEMENT: MRI is the method of choice for assessing TFCC lesions, with higher accuracy for central than peripheral abnormalities. The main indication for MR arthrography is the evaluation of TFCC foveal insertion lesions and peripheral non-Palmer injuries. KEY POINTS: ⢠Conventional radiography should be the initial imaging technique in the assessment of DRUJ instability. CT with static axial slices in neutral rotation, pronation, and supination is the most accurate method for evaluating DRUJ instability. ⢠MRI is the most useful technique in diagnosing soft-tissue injuries causing DRUJ instability, especially TFCC lesions. ⢠The main indications for MR arthrography and CT arthrography are foveal lesions of the TFCC.
Assuntos
Instabilidade Articular , Fibrocartilagem Triangular , Traumatismos do Punho , Humanos , Fibrocartilagem Triangular/diagnóstico por imagem , Traumatismos do Punho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Artrografia , Articulação do Punho/diagnóstico por imagem , Artroscopia/métodosRESUMO
BACKGROUND: Dual-layer spectral detector computed tomography (DLCT) may potentially improve CT arthrography through enhanced image quality and analysis of the chemical composition of tissue. PURPOSE: To evaluate the image quality of monoenergetic reconstructions from DLCT arthrography of the shoulder and assess the additional diagnostic value in differentiating calcium from iodine. MATERIAL AND METHODS: Images from consecutive shoulder DLCT arthrography examinations performed between December 2016 and February 2018 were retrospectively reviewed for hyperattenuating lesions within the labrum and tendons. The mean attenuation of the target lesion, noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) of the virtual monoenergetic images obtained at 40-200â keV were compared with conventional 140-kVp images. Two evaluators independently classified each target lesion as contrast media or calcification, without and with DLCT spectral data. Receiver operating curve (ROC) analysis was performed to assess the diagnostic performance of shoulder DLCT arthrography, without and with the aid of spectral data. RESULTS: The study included 20 target lesions (18 DLCT arthrography examinations of 17 patients). The SNRs of the monoenergetic images at 40-60â keV were significantly higher than those of conventional images (P < 0.05). The CNRs of the monoenergetic images at 40-70â keV were significantly higher than those of conventional images (P < 0.001). The ability to differentiate calcium from iodine, without and with DLCT spectral data, did not significantly differ (P = 0.441 and P = 0.257 for reviewers 1 and 2, respectively). CONCLUSION: DLCT had no additive value in differentiating calcium from iodine in small, hyperattenuating lesions in the labrum and tendons.
Assuntos
Cálcio , Iodo , Humanos , Artrografia , Ombro , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodosRESUMO
BACKGROUND: Bankart lesions accompany superior labrum anteroposterior (SLAP) lesions; these are called SLAP type 5. PURPOSE: To compare SLAP type 5 lesions using routine magnetic resonance arthrography (MRA) and thin-slice oblique sagittal proton density (PDW) sequences and correlation operation results. MATERIAL AND METHODS: In total, 181 patients were admitted with shoulder instability. The study was completed with 44 patients. The presence or absence of isolated Bankart and SLAP type 5 lesions in routine MRA and PDW oblique sagittal images were evaluated separately. Absence of rupture scored 0 points, suspected ruptures scored 1 point, and apparent ruptures scored 2 points. The two scores were compared with the shoulder arthroscopy findings. RESULTS: According to the findings in the shoulder arthroscopy, 40 patients had Bankart lesions and 17 patients had accompanying SLAP type 5 lesions. To detect a Bankart lesion, there was no significant difference between routine MRA sequences and PDW oblique sagittal images (P = 0.061). Routine MRA sensitivity was 95%, specificity 25%, positive predictive value (PPV) 92%, negative predictive value (NPV) 33%, while for PDW oblique sagittal images, sensitivity was 75%, specificity 100%, PPV 100%, and NPV 28.5%. In 8/17 type 5 SLAP lesions, routine MRA detected sensitivity 47%, specificity 92.6%, PPV 80%, and NPV 73.5%; in 14/17 SLAP type 5 lesions, PDW oblique sagittal images detected sensitivity 82%, specificity 100%, PPV 100%, and NPV 90% (P = 0.015). CONCLUSION: The PDW oblique sagittal images may play a significant role in assessing the anterior and superior extent of the tears.