1.
Nanotechnology ; 35(35)2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38806018

RESUMO

Nanotechnology has gained immense popularity and observed rapid development due to the remarkable physio-chemical properties of nanoparticles (NPs) and related nanomaterials. The green production of NPs has many benefits over traditional techniques because the current procedures are expensive, time-consuming, and involve harmful substances that limit their applicability. This study aimed to use a novel green source, theSalsola imbricata(SI) plant, which is commonly found in Central Asia and known for its medicinal properties as a reducing and stabilizing agent for the synthesis of AgNPs. The current study also utilized efficient statistical design, the Plackett-Burman Design (PBD) of Experiment method to synthesize the NPs. The characterization of NPs was carried out using UV-Vis spectroscopy, Fourier transform infrared spectroscopy, and scanning electron microscopy (SEM). The PBD results showed that only two out of four factorsi.e.AgNO3concentration and incubation time, were significant for the synthesis of SI-AgNPs. While remaining factors, incubation temperature and plant extract: AgNO3ratio were non-significant. The SEM analysis result showed that SI-AgNPs had a size of 20-50 nm. The SI-AgNPs demonstrated strong antibacterial activity against oral pathogens such asS. mutans and Lactobacillus acidophilus, with the highest efficacy observed at a concentration of 2 mg ml-1. The addition of SI-AgNPs in glass ionomer cement significantly increased the antibacterial activity of GIC againstS. mutans. Based on the results of the current study, the plant based AgNPs can be further evaluated in detail as alternate antimicrobial agent either alone or in combination with other antimicrobial agents for different dental applications.


Assuntos
Antibacterianos , Cimentos de Ionômeros de Vidro , Nanopartículas Metálicas , Testes de Sensibilidade Microbiana , Extratos Vegetais , Prata , Streptococcus mutans , Prata/química , Prata/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Antibacterianos/síntese química , Nanopartículas Metálicas/química , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/farmacologia , Streptococcus mutans/efeitos dos fármacos , Extratos Vegetais/química , Extratos Vegetais/farmacologia , Lactobacillus acidophilus/efeitos dos fármacos , Química Verde/métodos , Espectroscopia de Infravermelho com Transformada de Fourier
2.
Med Sci Monit ; 30: e943401, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38444156

RESUMO

BACKGROUND Several auxiliary features have been proposed to achieve sustainable retention for short-prepared dental crowns; however, achieving retention is challenging. This study aimed to assess the impact of increased total occlusal convergence and auxiliary preparation factors like box and groove on the retention form of short tooth preparations. MATERIAL AND METHODS Eighty resin machine-milled dies with a height of 3 mm and a deep chamfer margin of 1 mm were prepared to mimic the short-prepared molar. Initially, 2 teeth were prepared following the guidelines, and the total occlusal convergence was kept at 10° and 20°, respectively. Auxiliary features such as the proximal box and buccal groove were prepared on separate 20° dies. Eighty dies were prepared with 10 samples each for 10°, 20°, 20° with proximal box and 20° with buccal groove for zirconia (n=40) and metal crowns (n=40). Cementation was done with glass ionomer luting cement, and a pull-off test was conducted. Data were analyzed using one-way analysis of variance and post hoc fisher least significant difference test (P<0.05). RESULTS The highest mean was observed in the proximal box group with the metal crown (14.59), and the lowest in the group with 20° zirconia crowns (9.12). Within groups, the highest retentive values were found for the 20° taper with proximal box preparation; the lowest was for the 20° taper group. CONCLUSIONS Within the study limitations, it could be concluded that incorporating a proximal box or buccal groove in short tooth preparations with an increased total occlusal convergence improved retentive values.


Assuntos
Cimentos de Ionômeros de Vidro , Boca , Zircônio , Membrana Celular , Coroas
3.
Med Sci Monit ; 30: e943489, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38351604

RESUMO

Glass ionomer cement (GIC) is a self-adhesive dental restorative material composed of a polyacrylic acid liquid and fluoro-aluminosilicate glass powder. It is commonly used for cementation during dental restoration. This study aimed to systematically review the existing literature regarding the clinical performance of GIC in load-bearing dental restorations. A comprehensive literature search was conducted in EBSCO, PubMed, Embrace, and Cochrane databases. Only randomized controlled trials (RCTs) were included in the search, and a broad search technique was used, where inclusion and exclusion criteria were applied. After a thorough evaluation, 12 RCTs were extensively reviewed, and whether GIC is suitable for load-bearing restorations was determined. Significant variations in staining surface or margin, color match, translucency, esthetic anatomical form, retention, material fracture, marginal adaptation, surface luster, occlusal contour, wear, and approximal anatomical form indicated the unsuitability of GIC. By contrast, significance differences in patient view and periodontal response indicated that GIC is suitable. No significant differences in postoperative sensitivity, recurrence of caries, or tooth integrity were observed. Nevertheless, the results of the review demonstrated that the clinical performance of GIC is comparable to that of traditional restorative materials with regard to the parameters analyzed. GIC is a suitable restorative material for load-bearing restorations regarding surface margin, esthetic anatomical form, material retention and fracture, marginal adaptation, occlusal contour, wear, and approximal anatomical form. It reduces other parameters, such as postoperative sensitivity, recurrence of caries, and tooth integrity.


Assuntos
Restauração Dentária Permanente , Cimentos de Ionômeros de Vidro , Humanos , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/uso terapêutico , Restauração Dentária Permanente/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Cárie Dentária/terapia
4.
Med Sci Monit ; 30: e943237, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38343120

RESUMO

BACKGROUND This study evaluated the effects of milling (CADCAM), 3D printing, preparation taper angles (10-degree and 20-degree), auxiliary retentive features (groove and box), and provisional cement types (conventional and resin-based) on the adhesive failure stress of 3-mm short provisional crowns (PC). The research was motivated by the need to understand how digital dentistry technologies impact the retention and durability of provisional crowns. MATERIAL AND METHODS A total of 160 working models (3D-printed) and PCs [80 milled (CopraTemp)/80 printed (Asiga)] were fabricated from two 10- and 20-degree typodont master models and two 20-degree 3D-printed master models (groove and box), simulating a 3 mm high all-ceramic short PC. After provisional cementation with conventional (Kerr TempBond) and resin-based (ProviTemp) cements, 16 subgroups (n=10 each) underwent thermocycling (10 000 cycles; 5-55°C) and pull-off tests on a universal testing machine. Statistical analysis was performed using one-way ANOVA and post hoc Tukey test. RESULTS Conventional cement failed at lower stress for milled (47.68 to 73.54) and printed (48.40 to 77.91) as compared to resin cement for milled (104.2 to 137.27) and printed (184.85 to 328.84), respectively, with significant differences. Increased taper and groove decreased failure load except for the printed PC/resin cement combination. Use of proximal box preparation increased retention significantly. Except for 20-degree taper cemented with conventional cement, the differences in auxiliary retentive features for milled and printed provisional crowns were statistically significant at P≤0.05. CONCLUSIONS 3D-printed PC, resin-based cement, 10-degree taper, and proximal box preparation were associated with higher retention than milled, conventional cements, 20-degree taper, and vertical groove.


Assuntos
Adesivos , Cimentos de Resina , Cimentos de Resina/química , Teste de Materiais , Coroas , Impressão Tridimensional , Cimentos de Ionômeros de Vidro , Cimentos Dentários
5.
Med Sci Monit ; 30: e944110, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38685688

RESUMO

BACKGROUND A luting agent is a dental cement used to secure a dental restoration. This study aimed to evaluate retentive strength of 50 endodontically-treated single-rooted mandibular second premolars (extracted) restored using 5 common luting (cement) agents. MATERIAL AND METHODS Fifty single-rooted mandibular second premolars with adequate root length and uniform size/shape were decoronated. After completing endodontic biomechanical preparation and obturation, root canals of all specimens were prepared to receive a cast post core. Depending upon cementation type, CPC specimens were divided in 5 groups (10 each) (Gp): Zinc phosphate (Gp ZP), polycarboxylate (Gp PC), glass ionomer (Gp GI), resin-modified glass ionomer (Gp RGI), and resin cement (Gp RC). Retentive strength was determined using the adhesive failure pull-out test. Mean/standard deviations were calculated for tensile forces (in kilograms) and differences were determined using analysis of variance (ANOVA). Multiple comparison was performed using the t test. A P value of ≤0.05 indicated a statistically significant difference. RESULTS The order of mean tensile strength from higher to lower was Gp RC (21.46) >Gp RGI (18.17) >Gp GI (16.07) >Gp ZP (15.33) >Gp PC (13.63). Differences in retentive strengths between the cements were significant (P≤0.05). Multiple-group comparisons showed that except for Gp ZP and Gp GI, all groups differed significantly from each other. CONCLUSIONS All investigated cements provided optimal retentive strengths, with wide differences between them. Resin cements should be used when CPC removal is not anticipated, while polycarboxylate or zinc phosphate should be used if CPC removal is anticipated.


Assuntos
Dente Pré-Molar , Cimentos Dentários , Humanos , Mandíbula , Técnica para Retentor Intrarradicular , Cimentos de Ionômeros de Vidro , Cimentos de Resina , Resistência à Tração , Teste de Materiais/métodos , Restauração Dentária Permanente/métodos , Raiz Dentária/efeitos dos fármacos , Cimento de Fosfato de Zinco
6.
Biofouling ; 40(7): 390-401, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38945827

RESUMO

This study investigated the antimicrobial activity of surface pre-reacted glass ionomer eluate (S-PRG) against oral microcosm biofilms collected from the oral cavity of patients. Dental biofilm samples were collected from three volunteers to form microcosm biofilms in vitro. Initially, screening tests were carried out to determine the biofilm treatment conditions with S-PRG eluate. The effects of a daily treatment for 5 min using three microcosm biofilms from different patients was then evaluated. For this, biofilms were formed on tooth enamel specimens for 120 h. Biofilms treated with 100% S-PRG for 5 min per day for 5 days showed a reduction in the number of total microorganisms, streptococci and mutans streptococci. SEM images confirmed a reduction in the biofilm after treatment. Furthermore, S-PRG also reduced lactic acid production. It was concluded that S-PRG eluate reduced the microbial load and lactic acid production in oral microcosm biofilms, reinforcing its promising use as a mouthwash agent.


Assuntos
Biofilmes , Boca , Biofilmes/efeitos dos fármacos , Humanos , Boca/microbiologia , Streptococcus mutans/efeitos dos fármacos , Streptococcus mutans/crescimento & desenvolvimento , Anti-Infecciosos/farmacologia , Antissépticos Bucais/farmacologia , Ácido Láctico/farmacologia , Cimentos de Ionômeros de Vidro/farmacologia , Cimentos de Ionômeros de Vidro/química , Resinas Acrílicas/farmacologia , Resinas Acrílicas/química , Streptococcus/efeitos dos fármacos , Streptococcus/fisiologia , Propriedades de Superfície , Dióxido de Silício
7.
Clin Oral Investig ; 28(6): 301, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38710794

RESUMO

OBJECTIVES: To undertake a cost-effectiveness analysis of restorative treatments for a first permanent molar with severe molar incisor hypomineralization from the perspective of the Brazilian public system. MATERIALS AND METHODS: Two models were constructed: a one-year decision tree and a ten-year Markov model, each based on a hypothetical cohort of one thousand individuals through Monte Carlo simulation. Eight restorative strategies were evaluated: high viscosity glass ionomer cement (HVGIC); encapsulated GIC; etch and rinse adhesive + composite; self-etch adhesive + composite; preformed stainless steel crown; HVGIC + etch and rinse adhesive + composite; HVGIC + self-etch adhesive + composite, and encapsulated GIC + etch and rinse adhesive + composite. Effectiveness data were sourced from the literature. Micro-costing was applied using 2022 USD market averages with a 5% variation. Incremental cost-effectiveness ratio (ICER), net monetary benefit (%NMB), and the budgetary impact were obtained. RESULTS: Cost-effective treatments included HVGIC (%NMB = 0%/ 0%), encapsulated GIC (%NMB = 19.4%/ 19.7%), and encapsulated GIC + etch and rinse adhesive + composite (%NMB = 23.4%/ 24.5%) at 1 year and 10 years, respectively. The benefit gain of encapsulated GIC + etch and rinse adhesive + composite in relation to encapsulated GIC was small when compared to the cost increase at 1 year (gain of 3.28% and increase of USD 24.26) and 10 years (gain of 4% and increase of USD 15.54). CONCLUSION: Within the horizon and perspective analyzed, the most cost-effective treatment was encapsulated GIC restoration. CLINICAL RELEVANCE: This study can provide information for decision-making.


Assuntos
Hipoplasia do Esmalte Dentário , Restauração Dentária Permanente , Cimentos de Ionômeros de Vidro , Humanos , Brasil , Árvores de Decisões , Hipoplasia do Esmalte Dentário/terapia , Restauração Dentária Permanente/métodos , Restauração Dentária Permanente/economia , Cimentos de Ionômeros de Vidro/uso terapêutico , Cadeias de Markov , Dente Molar , Hipomineralização Molar , Método de Monte Carlo
8.
Clin Oral Investig ; 28(1): 97, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38225525

RESUMO

OBJECTIVE: The study aims to evaluate the effect of a glass ionomer cement (GIC; Fuji 9 Gold Label, GC) with added calcium orthophosphate particles and a calcium silicate cement (CSC; Biodentine, Septodont) regarding ion release, degradation in water, mineral content, and mechanical properties of demineralized dentin samples. METHODS: GIC, GIC + 5% DCPD (dicalcium phosphate dihydrate), GIC + 15% DCPD, GIC + 5% ß-TCP (tricalcium phosphate), GIC + 15% ß-TCP (by mass), and CSC were evaluated for Ca2+/Sr2+/F- release in water for 56 days. Cement mass loss was evaluated after 7-day immersion in water. Partially demineralized dentin disks were kept in contact with materials while immersed in simulated body fluid (SBF) at 37 °C for 56 days. The "mineral-to-matrix ratio" (MMR) was determined by ATR-FTIR spectroscopy. Dentin hardness and elastic modulus were obtained by nanoindentation. Samples were observed under scanning and transmission electron microscopy. Data were analyzed by ANOVA/Tukey test (α = 0.05). RESULTS: Ca2+ release from CSC and GIC (µg/cm2) were 4737.0 ± 735.9 and 13.6 ± 1.6, respectively. In relation to the unmodified GIC, the addition of DCPD or ß-TCP increased ion release (p < 0.001). Only the dentin disks in contact with CSC presented higher MMR (p < 0.05) and mechanical properties than those restored with a resin composite used as control (p < 0.05). Mass loss was similar for GIC and CSC; however, the addition of DCPD or ß-TCP increased GIC degradation (p < 0.05). CONCLUSION: Despite the increase in ion release, the additional Ca2+ sources did not impart remineralizing capability to GIC. Both unmodified GIC and CSC showed similar degradation in water. CLINICAL RELEVANCE: CSC was able to promote dentin remineralization.


Assuntos
Compostos de Cálcio , Fosfatos de Cálcio , Cálcio , Cimentos de Ionômeros de Vidro , Silicatos , Cimentos de Ionômeros de Vidro/farmacologia , Cimentos de Ionômeros de Vidro/química , Cálcio/análise , Fosfatos/análise , Cimento de Silicato/análise , Cimento de Silicato/farmacologia , Dentina , Água/química , Teste de Materiais
9.
Clin Oral Investig ; 28(6): 345, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809289

RESUMO

OBJECTIVES: This study aimed to evaluate the effect of restorations made with a glass-hybrid restorative system (GHRS), a high-viscosity glass ionomer restorative material (HVGIC), a high-viscosity bulk-fill composite resin (HVB), a flowable bulk-fill composite resin (FB), and a nanohybrid composite resin (NH), which are commonly preferred in clinical applications on the fracture resistance of teeth in-vitro. MATERIALS AND METHODS: One hundred intact human premolar teeth were included in the study. The teeth were randomly divided into ten groups (n = 10). No treatment was applied to the teeth in Control group. Class II cavities were prepared on the mesial surfaces of the remaining ninety teeth in other groups. For restoration of the teeth, a GHRS, a HVGIC, a HVB, a FB, and a NH were used. Additionally, in four groups, teeth were restored using NH, GHRS, and HVGIC with open and closed-sandwich techniques. After 24 h, fracture resistance testing was performed. One-way ANOVA and Tukey HDS tests were used for statistical analysis of the data. RESULTS: The fracture resistance values of Control group were statistically significantly higher than those of GHRS, HVGIC, FB, NH, HVGIC-CS, GHRS-OS, and HVGIC-OS groups(p < 0.05). There was no statistically significant difference observed between the fracture resistance values of Control, HVB, and GHRS-CS groups (p > 0.05). CONCLUSION: It can be concluded that the use of HVB and the application of GHRS with a closed-sandwich technique may have a positive effect on the fracture resistance of teeth in the restoration of wide Class II cavities. CLINICAL RELEVANCE: The use of high-viscosity bulk-fill composite resin and the application of glass-hybrid restorative system with the closed-sandwich technique in the restoration of teeth with wide Class II cavities could increase the fracture resistance of the teeth.


Assuntos
Dente Pré-Molar , Resinas Compostas , Restauração Dentária Permanente , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro , Teste de Materiais , Fraturas dos Dentes , Resinas Compostas/química , Humanos , Técnicas In Vitro , Restauração Dentária Permanente/métodos , Cimentos de Ionômeros de Vidro/química , Fraturas dos Dentes/prevenção & controle , Viscosidade , Propriedades de Superfície , Preparo da Cavidade Dentária/métodos , Resinas Acrílicas/química
10.
Clin Oral Investig ; 28(1): 104, 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38243032

RESUMO

OBJECTIVE: To evaluate the 5-year clinical performance of a glass hybrid restorative system and a nano-hybrid resin composite in moderate to large two-surface class II cavities. MATERIALS AND METHODS: This study was carried out by dental schools in Zagreb, Croatia; Izmir, Turkey; Belgrade, Serbia; and Milan, Italy. A total of 180 patients requiring two class-II two-surface restorations in the molars of the same jaw were recruited. The teeth were randomly restored with either a nano-hybrid resin composite (Tetric EvoCeram, Ivoclar Vivadent) or a glass-hybrid material (EQUIA Forte, GC). During the 5-year follow-up, two calibrated evaluators at each centre scored the restorations annually using the FDI-2 scoring system. The survival rates were calculated using the Kaplan-Meier method and compared using non-parametric matched pair tests (p < 0.05). RESULTS: There were no statistically significant differences between the overall survival and success rates of the two types of restorations (p>0.05). The success rates (FDI-2 scores 1-3) for EQUIA Forte were 81.9% (average annual failure rate: 3.9%) and 90.7% for Tetric EvoCeram (average annual failure rate: 1.9%). The survival rates (FDI-2 scores 1-4) for EQUIA Forte and Tetric EvoCeram were 94.5% and 94.4%, respectively, with an average annual failure rate of 1.1%. CONCLUSIONS: In terms of success and survival rates, both the glass-hybrid restorative system and the nano-hybrid resin composite have been shown to perform satisfactorily. CLINICAL RELEVANCE: The results of this study indicate that EQUIA Forte can be one of the therapeutic options for moderate to large two-surface class II restorations of posterior teeth.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Humanos , Restauração Dentária Permanente/métodos , Resinas Compostas/uso terapêutico , Materiais Dentários , Dente Molar , Cárie Dentária/terapia , Vidro , Cimentos de Ionômeros de Vidro/uso terapêutico
11.
ScientificWorldJournal ; 2024: 9420336, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38205145

RESUMO

Methods: 22 specimens prepared with Cention and RMGIC were embedded in primary teeth mounted in acrylic for analysing shear bond strength. Shear bond strength was analysed using a universal testing machine. The modes of failure in samples were observed under a stereomicroscope and scanning electron microscope. 22 customised samples of Cention N and RMGIC were prepared and categorised as group A and group B, respectively. The flexural and compressive strengths of these samples were evaluated using a universal testing machine. Results: The shear bond strength of RMGIC was higher than that of Cention N, whereas the compressive and flexural strengths of Cention N were significantly higher than those of RMGIC. The modes of failure were predominantly adhesive followed by mixed failures. Conclusion: The results of this study suggest that Cention N demonstrated superior mechanical properties compared with RMGIC and can therefore be recommended for restorations in primary posterior teeth. Cention N being a smart, esthetic, self-cured, or dual-cured material with better mechanical properties offers a wide range of applicability in primary teeth.


Assuntos
Cimentos de Ionômeros de Vidro , Dente Decíduo , Força Compressiva
12.
J Craniofac Surg ; 35(1): e81-e83, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37943067

RESUMO

Calcium phosphate cement remains the choice biomaterial for cranial reconstruction and augmentation in pediatric patients after 90% completion of cranial growth, especially compared with other nonallograft alternatives. While trauma to the site of calcium phosphate augmentation is a known risk for cement fracture, subsequent micro-fragmentation and sequestration of the cement beneath the fracture site can produce a localized inflammatory reaction that requires surgical intervention to adequately address. The authors present the course of a patient undergoing a prolonged inflammatory reaction to calcium phosphate micro-fragmentation after trauma to the site of previous augmentation performed to mend bitemporal hollowing. Cement microfragmentation and migration through an associated nondisplaced fracture of the outer table required extensive debridement of the underlying diploe before the resolution was achieved. This case illustrates the need for appropriate evaluation in cases of trauma to areas with cement to mitigate the need for extensive surgical management.


Assuntos
Cimentos Ósseos , Fraturas Ósseas , Humanos , Criança , Cimentos Ósseos/efeitos adversos , Crânio/cirurgia , Inflamação , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Fosfatos de Cálcio/uso terapêutico
13.
Am J Dent ; 37(1): 19-23, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38458978

RESUMO

PURPOSE: To evaluate and compare changes on the surface roughness of conventional and colored compomers used in pediatric dentistry caused by beverages frequently consumed by children. METHODS: 176 conventional and colored compomer discs were prepared. The discs were divided into four equal subgroups and incubated in different beverages: distilled water, milk, fruit juice, and cola. The surface roughness of the samples was measured and recorded on Days 1, 7, 14, 21, and 28. The data obtained were statistically analyzed. RESULTS: In distilled water and milk, the surface roughness of the conventional compomer was higher than the colored compomer after Day 7 (P< 0.05). In fruit juice and cola, the surface roughness of conventional and colored compomers was similar at all timepoints (P< 0.05). There was a significant difference between discs incubated in distilled water and milk, on Days 21 and 28 (P< 0.05). The colored compomer showed the highest roughness in cola on Day 1, whereas the conventional compomer showed the highest roughness in milk on Day 21. CLINICAL SIGNIFICANCE: Cola caused the highest surface roughness on the surface of colored compomers, whereas milk caused the highest surface roughness on conventional compomers.


Assuntos
Compômeros , Resinas Compostas , Criança , Humanos , Bebidas , Água , Propriedades de Superfície , Teste de Materiais , Cimentos de Ionômeros de Vidro
14.
Odontology ; 112(1): 169-176, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37422770

RESUMO

The aim of this study is to evaluate the effect of pre-ceramic soldering on the marginal and internal fit of 4-unit zirconia fixed dental prostheses (FPDs) that have two abutments and two pontics. 4-unit zirconia frameworks (Zirkonzahn ICE Translucent) (Z Group) and monolithic zirconia (Zirkonzahn Prettau) (M Group) FPDs were manufactured. Groups were divided into two groups (n = 10) control (ZC and MC) and soldering (ZS and MS). Samples of ZS and MS groups were cut into two pieces under cooling water and soldered with a bonding material (DCM Zircon HotBond). The marginal and internal fit of the restorations were measured from 36 points of each sample and cement space volume was calculated using reverse engineering software (Geomagic Design X). The mean and standard deviations were submitted to Generalized Linear Mixed Model (GLMM) analysis (α = 0.05). Statistical differences between groups before and after pre-ceramic soldering on point measurements were found. In total cement spacing measurements, a significant difference was found amongst all groups (P < 0.05). However, in premolars, a statistically significant difference was found between ZC and ZS groups and MC and MS groups (P < 0.05). All discrepancies after pre-ceramic soldering were found to be lower than before.


Assuntos
Porcelana Dentária , Prótese Dentária , Porcelana Dentária/química , Cerâmica/química , Materiais Dentários/química , Zircônio/química , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Adaptação Marginal Dentária , Prótese Parcial Fixa , Desenho Assistido por Computador
15.
J Esthet Restor Dent ; 36(3): 503-510, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37994681

RESUMO

OBJECTIVE: Measure and compare the mechanical properties, translucency, and fluoride-releasing capabilities of EQUIA Forte HT against Fuji IX GP and ChemFil Rock. MATERIALS AND METHODS: Ten specimens of each material were fabricated for compressive strength (CS), flexural strength (FS), and surface hardness analysis at 24 h and 7 days. The L*a*b* values were measured against a black-and-white background using a spectrophotometer to analyze the translucency parameter (TP). Fluoride release was recorded after 2 months of immersion in distilled water. The mean data was analyzed by 1- and 2-way ANOVA (α = 0.5). RESULTS: EQUIA Forte HT showed higher CS, surface hardness, and FS values (p < 0.05) compared with Fuji IX GIC, while no significant difference was found in FS values between EQUIA Forte HT and Chemfil Rock (p > 0.05). The EQUIA Forte HT exhibited significantly higher translucency in comparison to both ChemFil Rock (p < 0.001) and Fuji IX GICs (p < 0.05). An increase (p > 0.05) of fluoride release was observed for EQUIA Forte HT. CONCLUSION: The EQUIA Forte HT Glass-ionomer cements (GIC) offers enhanced translucency, improved strength, and enhanced fluoride-releasing properties compared to the traditionally used Fuji IX GIC and ChemFil Rock GICs. This material might have a wide range of clinical applications due to its improved strength and optical properties. CLINICAL SIGNIFICANCE: Glass-ionomer dental restorative materials possess unique advantageous characteristics. However, its poor mechanical and optical properties have typically limited its clinical applications. Efforts to improve these properties have resulted in enhanced GICs. EQUIA Forte HT GIC offers enhanced mechanical and optical properties with potential applications in posterior and anterior restorative procedures.


Assuntos
Silicatos de Alumínio , Materiais Dentários , Fluoretos , Cimentos de Ionômeros de Vidro , Força Compressiva , Dureza , Teste de Materiais
16.
J Esthet Restor Dent ; 36(4): 573-587, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37902283

RESUMO

OBJECTIVES: To provide a 3-year follow-up of previously treated patients to assess and compare the periodontal responses and clinical performance of proximal subgingival open sandwich restorations. MATERIALS AND METHODS: Ninety-five adults participated in the study, with a combined total of 120 compound Class II cavities. These cavities had gingival margins located below the CEJ. Four different restorative materials were used to elevate the dentin/cementum gingival margins of the cavities: resin-modified glass ionomer, glass hybrid, flowable bulk-fill composite, or ion-releasing material, which were then completed with the same overlaying composite. Different periodontal and clinical evaluations, based on the criteria set by the World Dental Federation (FDI) criteria, were performed at different time intervals, including baseline, 6 months, 1, 2, and 3 years. RESULTS: The type of base material did not affect the periodontal evaluations. There were no statistically significant differences between different time intervals or base material groups in any of the evaluated FDI parameters. However, the ion-releasing material scored significantly worse in the radiographic evaluation than any of the other groups. CONCLUSIONS: All tested materials are suitable for proximal subgingival open sandwich restorations, as long as the restoration/tooth margin is at least 2-mm away from the bone crest. CLINICAL SIGNIFICANCE: Clinicians can confidently choose any of the tested materials for proximal subgingival open sandwich restorations, as they have shown good outcomes from both periodontal and clinical perspectives.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Adulto , Humanos , Resinas Compostas , Materiais Dentários , Restauração Dentária Permanente/métodos , Cimentos de Ionômeros de Vidro , Método Duplo-Cego
17.
J Esthet Restor Dent ; 36(1): 107-115, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37933738

RESUMO

OBJECTIVES: To evaluate minimally invasive restorations' capacity to mask discolored teeth and explore the impact of ceramic thickness, translucency, and cement color. MATERIALS AND METHODS: Twenty-four assessment pairs of naturally colored and discolored bovine dentin samples were formed, using lithium disilicate specimens in six different thicknesses (0.3-0.8 mm), two different translucencies (high, low), and two cements (transparent, tooth-colored). Evaluators assessed the color differences in each assessment pair, and the threshold for detecting a color difference was determined using sequential testing and the Bonferroni-Holm method. RESULTS: A thickness of 0.6 mm effectively masked color differences using high translucent ceramic with transparent cement, detectable differences were still observed at 0.7/0.8 mm. A threshold thickness of 0.4 mm was seen using high translucent ceramic and tooth-colored cement, with color differences still discernible at 0.5 and 0.8 mm. A threshold thickness of 0.4 mm was detected using low translucent ceramic and transparent cement, while detectable differences persisted at 0.5, 0.7, and 0.8 mm. A 0.5 mm threshold thickness was observed when using low translucent ceramic and tooth-colored cement, and no detectable color differences were detected beyond this thickness. CONCLUSIONS: Masking can be achieved with a thickness of 0.4-0.5 mm using a low translucent material and tooth-colored cement. CLINICAL SIGNIFICANCE: Understanding the impact of ceramic thickness, translucency, and cement color can aid clinicians in making informed decisions for achieving the best esthetic outcomes while preserving tooth structure. Effective masking can be accomplished with ceramic thicknesses starting at 0.4 mm, especially when employing a low translucent material and tooth-colored cement. However, clinicians should be aware that discolorations may still be detectable in certain scenarios when using minimally invasive lithium disilicate restorations.


Assuntos
Cerâmica , Porcelana Dentária , Animais , Bovinos , Porcelana Dentária/química , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Teste de Materiais , Cor , Propriedades de Superfície
18.
J Esthet Restor Dent ; 36(5): 702-709, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38108583

RESUMO

OBJECTIVE: This study aims to compare the clinical and radiographic efficacy of Equia system bulk fill glass hybrid material with composite resins in the permanent restoration of pediatric patients' permanent teeth. MATERIALS AND METHODS: The study included 44 pediatric patients aged 8-16 who applied to Necmettin Erbakan University Pediatric Dentistry Department. The groups were formed as symmetrical teeth in the same patient using the split-mouth design. The study included class I caries lesions of 144 permanent teeth. Group 1 was restored with the Equia system bulk fill glass hybrid material (Equia Forte HT + Equia Forte Coat [GC, Co, Tokyo, Japan]) (n = 72) and Group 2 with the Charisma Smart universal composite resin (Kulzer, Gmbh, Hanau, Germany) + Clearfil SE Bond (Kuraray, Noritake, Sakazu, Okayama) (n = 72). Evaluations were performed clinically and radiographically by two physicians in 2nd week, 3rd month, 6th month, and 12th month and the results were recorded. Clinical evaluation was carried out using modified-USPHS criteria. Obtained data were statistically analyzed using Kendall's W test and Cochran's Q test for the comparison within the group, and the Chi-square test for the comparison between groups. RESULTS: Among the materials utilized in the study, there was no statistically significant difference in marginal adaptation, marginal discoloration, retention, anatomical form, postoperative sensitivity, and secondary caries according (p > 0.05). Group 2 outperformed statistically significant Group 1 in terms of color match in all periods (p < 0.05). While there was no statistically significant difference in surface structure between the groups in 2nd week and 3rd month (p > 0.05), there was a statistically substantial difference in 6th, and 12th months (p < 0.05). No secondary caries or periapical lesions were found in any restorations during radiographic evaluation. CONCLUSION: After a year, the clinical performance of both Equia and composite resins was equivalent and successful in the majority of the measures against which they were evaluated. CLINICAL SIGNIFICANCE: Based on the results of the research, Equia system bulk fill glass hybrid restorations are considered a viable alternative to composite resins in class I permanent teeth restorations.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Humanos , Criança , Restauração Dentária Permanente/métodos , Cimentos de Ionômeros de Vidro , Adaptação Marginal Dentária , Materiais Dentários , Resinas Compostas , Cárie Dentária/terapia
19.
J Esthet Restor Dent ; 36(8): 1138-1152, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38475965

RESUMO

OBJECTIVE: This randomized, double-blind clinical investigation assessed the performance of two high-viscosity glass-ionomer systems and a bulk-fill composite in different cavity types. MATERIALS AND METHODS: In 146 participants, 360 (class I, II, and V) cavities were restored using three different materials (Equia Forte HT, Chemfill Rock, and SonicFill 2) with equal allocation. Using modified World Dental Federation criteria, restorations were assessed after 1 week, 6 months, and 18 months by an experienced examiner. Statistical analysis was conducted using Fisher's exact and Wilcoxon signed rank tests (α = 0.05). RESULTS: After 18 months, 267 restorations were assessed in 116 participants. After 18 months, 5 Equia Forte HT restorations failed due to debonding and fracture. Only one loss was observed in the Chemfill Rock restorations. Equia Forte HT exhibited significantly lower retention than SonicFill 2 after 18 months (p = 0.019), irrespective of cavity type. At 1 week, 3 Class I restorations with SF showed postoperative sensitivity. The type of cavity did not affect the performance of the restorative materials used (p > 0.05). CONCLUSION: Equia Forte HT and Chemfill Rock presented similar clinical performance regardless of color match. Equia Forte HT showed a lower performance compared to SonicFill 2. CLINICAL SIGNIFICANCE: Glass-hybrid materials presented a lower performance in terms of color match or retention when compared to a sculptable bulk-fill composite resin.


Assuntos
Resinas Compostas , Humanos , Resinas Compostas/química , Método Duplo-Cego , Viscosidade , Feminino , Pessoa de Meia-Idade , Adulto , Masculino , Restauração Dentária Permanente/métodos , Cimentos de Ionômeros de Vidro/química , Preparo da Cavidade Dentária
20.
J Prosthet Dent ; 131(1): 100.e1-100.e5, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37867016

RESUMO

STATEMENT OF PROBLEM: The necessity of roughening the intaglio surface of zirconia crowns to achieve adequate retention is unclear. PURPOSE: The purpose of this clinical simulation study was to evaluate the retention of airborne-particle-abraded and nonabraded monolithic zirconia crowns using 3 different cement types. MATERIAL AND METHODS: Extracted human molars were used and prepared with a 10-degree taper. Impressions were made of the prepared teeth with a polyvinyl siloxane (PVS) material, and dies were made with Type 4 gypsum. Each die was scanned with a NobelProcera 1G Scanner, and the standard tessellation language (STL) files were transferred electronically to the Nobel Biocare production site, where a bar was added virtually on top of each crown and parameters were set for milling. Seventy-two Procera zirconia crowns were generated, of which half were airborne-particle abraded on the intaglio surface with 50-µm alumina particles at 400 to 500 kPa for 15 seconds. The other 36 received no intaglio treatment other than cleaning. Both groups of 36 crowns were divided into 3 subgroups of 12 specimens. The area of each preparation was calculated using a computer-aided design software program. The specimens were distributed to attain similar mean surface areas among the cementation groups. The crowns were cemented onto the specimen with a controlled force of 196 N. The 3 cements used were self-adhesive, modified resin RelyX Unicem Aplicap, resin-modified glass ionomer RelyX Luting, and a composite resin, Panavia F2.0 with ED Primer A & B. All specimens were thermocycled (5 °C to 55 °C) for 5000 cycles and then removed axially with a universal testing machine (Instron Model 5585H) at a crosshead speed of 0.5 mm/min. The removal force was recorded, and stress of dislodgement was calculated for each crown. A 2-way analysis of variance was used for statistical analyses. The type of failure was analyzed with the chi-squared test of association for independent samples (α=.05 for all tests). RESULTS: The mean dislodging force for crowns with airborne-particle abraded intaglio was 5.4 MPa, which was statistically greater than the mean of 3.2 MPa for nonabraded specimens (P<.001). No significant differences related to the dislodging stresses were detected among the 3 cements (P=.109). The mode of failure was similar whether abraded or not, with 50% of specimens retaining cement in the crown after separation. CONCLUSIONS: Alumina airborne-particle abrasion of the intaglio of zirconia to create surface roughness is beneficial in retaining the crowns, regardless of the cement type. The nonabraded crowns demonstrated significantly lower retentive stress with crown removal. The principal mode of failure was similar whether the zirconia intaglio was airborne-particle abraded or not. The most common mode of failure (>50% of specimens) was at least three-fourths of the cement remaining within the crown.


Assuntos
Óxido de Alumínio , Materiais Dentários , Humanos , Cimentos Dentários , Coroas , Cimentos de Resina , Zircônio , Cimentos de Ionômeros de Vidro , Teste de Materiais , Análise do Estresse Dentário , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS